STRUMENTAZIONE ELETTRONICA

Dimensione: px
Iniziare la visualizzazioe della pagina:

Download "STRUMENTAZIONE ELETTRONICA"

Transcript

1 STRUMENTAZIONE ELETTRONICA

2 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy Serie GDS 3000 OSCILLOSCOPI 500/350/250/150MHz with 2/4 Channels 5GSa/s RT or 100GSa/s ET Sampling Rate Independent Memory for Each Channel PO Technology Large 8-inch 800x600 Display Split Screen Function 3 Built-in Impedances (50Ω/75Ω/1MΩ) Power Analysis Software (Optional) Serial Bus Analysis Software for I2C, SPI and UART (Optional) GDS-3504 GDS-3502 GDS-3354 GDS-3352 GDS-3254 GDS-3252 GDS-3154 GDS-3152 Waveform Technology PO ( isual Persistence Oscilloscope ) Display 8" TFT LCD SGA Bandwidth (MHz) Number of Channel Memory Depth 25k per channel Sample Rate 4GSa/s (RTS) - 100GSa/s (ETS) 5GSa/s (RTS) - 100GSa/s (ETS) ertical Resolution 8-bit ertical Sensitivity 2m/div ~ - 2m/div ~ 1/div Time Base Range 1ns/div ~ 100s/div - ( increments) Input Impedance Selection 1MΩ / 75Ω / 50Ω Auto Measurement 28 Waveform Memory 24 Panel Setup Memory 20 Auto-Set Auto/Normal Trigger ALT Trigger T Trigger Cursor Readout XY Mode Zoom Go/NoGo Zoom FFT, *It Support From App Software. Counter Function Function Generator - Logic Analyzer - Data Logger - Digital Storage Go/NoGo Output Interface USB Host/Device, RS-232, GPIB(Opt.), Lan SGA Output Buzzer Alarm PictBridge Compatible Battery Power Operation - LED Indicators - Z-Axis Input - Labiew Driver Power Source AC 100 ~ 240

3 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GDS 2000A 300MHz/200MHz/100MHz/70MHz Bandwidth,2 or 4 Input Channel 2GSa/s Real-time Sampling Rate and 100GSa/s Equivalent Time Sampling Rate 2Mega Points Record Length 1m /div to 10/div of ertical Range 1ns/div to 100s/div of Time Base Range 80,000 wfm/s of Waveform Update Rate 8 inch 800*600 High Resolution TFT LCD Display Built-in Segmented Memory and Waveform Search Functions to Optimize the Efficiency of Record Length Zoom Window and Play/Pause can Rapidly Navigate the Waveforms 36 Automatic Measurement Functions Offers arious Measurement Selections Optional 8 or 16 digital channel with Logic analyzer(mso) Optional Function Generator Flexible Remote Control Connectivity(Standard:USB ;Option:LAN/GPIB) Upgradable CAN/LIN bus analysis,advanced Logic,Datalog,DM and H-expansion functionalities GDS-2304A GDS-2302A GDS-2204A GDS-2202A GDS-2104A GDS-2102A GDS-2074A GDS-2072A Waveform Technology PO ( isual Persistence Oscilloscope ) Display 8" TFT LCD SGA Bandwidth (MHz) Number of Channel Memory Depth Sample Rate ertical Resolution ertical Sensitivity Time Base Range Input Impedance Selection Max. 2M pts 2GSa/s (RTS) 100GSa/s (ETS) 8-bit 1m/div ~ 10/div 1ns/div ~ 100s/div Auto Measurement 36 Waveform Memory 24 Panel Setup Memory 20 Auto-Set Auto/Normal Trigger ALT Trigger T Trigger Cursor Readout XY Mode Zoom Go/NoGo Zoom FFT Counter Function Function Generator Logic Analyzer Data Logger Digital Storage Go/NoGo Output Interface SGA Output Buzzer Alarm PictBridge Compatible 1MΩ Opt. Opt., *It Support From App Software. USB Host/Device, RS-232, GPIB(Opt.), Lan(Opt.) Battery Power Operation - LED Indicators - Z-Axis Input - Labiew Driver Power Source Opt. AC 100 ~ 240

4 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GDS 2000E 200/100/70MHz Bandwidth Selection; 2 or 4 Channels 1GSa/s Real-Time Sampling Rate for Each Channel (2ch model) ; 1GSa/s Maximum Real-Time Sampling Rate (4ch model) Standard 10M Maximum Memory Depth and PO Waveform Display Technology Waveform Update Rate of 120,000 wfm/s 8 WGA TFT LCD Display FFT with Maximum 1M points to Provide Higher Frequency Domain Resolution Measurement High and Low Pass Digital Filter Functions 29,000 Sections of Segmented Memory and Waveform Search Functions I2C/SPI/UART/CAN/LIN Serial Bus Trigger and Decoding Function Data Log Function Tracks Signal Changes Up To 100 hours Provide Remote Internet Storage Function GDS-2072E GDS-2074E GDS-2102E GDS-2104E GDS-2202E GDS-2204E Channels 2ch+Ext 4ch 2ch+Ext 4ch 2ch+Ext 4ch Bandwidth DC~70MHz DC~70MHz DC~100MHz DC~100MHz DC~200MHz DC~200MHz (-3dB) (-3dB) (-3dB) (-3dB) (-3dB) (-3dB) Rise time 5ns 5ns 3.5ns 3.5ns 1.75ns 1.75ns Bandwidth Limit 20MHz 20MHz 20MHz 20MHz 20M/100MHz 20M/100MHz ertical Sensitivity Input Coupling AC, DC, GND Resolution 8 bit /:1m~10/div Input Impedance 1MΩ// 16pF approx. DC Gain Accuracy ±(3%)when 2m/div or greater is selected / ±(5%)when 1m/div is selected; Polarity Normal & Invert Maximum Input oltage 300rms, CAT I Offset Position Range 1m/div ~ 20m/div : ±0.5 / 50m/div ~ 200m/div : ±5 / 500m/div ~ 2/div : ±25 / 5~10/div : ±250 Waveform Signal Process +, -,,, FFT, FFTrms,User Defined Expression. / FFT:1Mpts / FFT: Spectral magnitude. Set FFT ertical Scale to Linear RMS or db RMS / FFT Window : Rectangular, Hamming, Hanning, Blackman-Harris Trigger Trigger Mode Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single Sequence Source CH1,CH2, CH3, CH4, Line, EXT* / *EXT only on dual channel models Trigger Type Edge, Pulse Width(Glitch), ideo, Pulse Runt, Rise & Fall(Slope), Alternate, time out, Event-Delay (~65535 events), Time-Delay (Duration,4nS~10S), Bus Hold-off range 4ns~10s Coupling AC,DC,LF rej.,hf rej.,noise rej. Sensitivity 1div External Trigger (2ch model only) Range ±15 Sensitivity DC ~ 100MHz Approx. 100m 100MHz ~ 200MHz Approx. 150m Input Impedance 1MΩ±3%~16pF Horizontal Time base Range 1ns/div ~ 100s/div (1-2-5 increments) ROLL: 100ms/div ~ 100s/div Pre-trigger 10 div maximum Post-trigger 2,000,000 div maximum. Time base Accuracy ±50 ppm over any 1 ms time interval Real Time Sample Rate Max.:1GSa/s (4ch model) - Per channel 1GSa/s (2ch model) Record Length Max:10Mpts Acquisition Mode Normal, Average, Peak Detect, Single Peak Detection 2ns (typical) Average selectable from 2 to 256 X-Y Mode Phase Shift ±3 at 100kHz Y-Axis Input Channel 2; Channel 4* / *four channel models only X-Axis Input Channel 1; Channel 3* / *four channel models only Cursors and Measurement Cursors Amplitude, Time, Gating available Unit: Seconds(s),Hz(1/s),Phase(degree),Ration(%) Automatic Measurement 36 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, RO Shoot, FO Shoot, RPRE Shoot, FPRE Shoot, Frequency, Period, Rise Time, Fall Time, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase,Cursor measurements Control Panel Function Auto counter 6 digits, range from 2Hz minimum to the rated bandwidth Autoset Save Setup Save Waveform Display TFT LCD Type Display Resolution Interpolation Waveform Display Waveform Update Rate Display Graticule Display mode Interface USB Port Ethernet(LAN) Port Go-NoGo BNC Kensington Style Lock Miscellaneous Multi-language menu operation environment Time clock Dimensions - Weight Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset 20set 24set 8" TFT LCD WGA color display 800 horizontal 480 vertical pixels (WGA) Sin(x)/x Dots, vectors, variable persistence (16ms~4s), infinite persistence 120,000 waveforms per second, maximum 8 x 10 divisions YT ;XY USB 2.0 High-speed host port X1, USB High-speed 2.0 device port X1 RJ-45 connector, 10/100Mbps with HP Auto-MDIX 5 Max/10mA TTL open collector output Rear-panel security slot connects to standard Kensington-style lock. Available Temperature: 0 C to 50 C. Relative Humidity 80% at 40 C or below; 45% at 41 C ~ 50 C. Time and Date,Provide the Date/Time for saved data 384mmX208mmX127.3mm - 2.8kg

5 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GDS 1000A-U 150/100/70MHz Bandwidths 1GSa/s Real-Time Sample Rates Maximum, 25GSa/s Equivalent-Time 2Mega Points Record Length 2m~10 ertical Scale 1ns~50s Horizontal Range Up to 27 Automatic Measurements 5.7" TFT LCD Display USB Host and Device Interface Supported Go/NoGo Function Data Logger Limited Lifetime Warranty GDS-1152A-U GDS-1102A-U GDS-1072A-U Waveform Technology Memory-Prime Display 5.7" TFT LCD Color Bandwidth (MHz) Number of Channel Memory Depth 2M Points Sample Rate 1GSa/s (RTS) / 25GSa/s (ETS) ertical Resolution 8-bit ertical Sensitivity 2m/div ~ 10/div Time Base Range 1ns/div ~ 50s/div Input Impedance Selection 1MΩ Auto Measurement 27 Waveform Memory 15 Panel Setup Memory 15 Auto-Set Auto/Normal Trigger ALT Trigger - T Trigger Cursor Readout XY Mode Zoom Go/NoGo Zoom FFT Counter Function Function Generator - Logic Analyzer - Data Logger Digital Storage Go/NoGo Output - Interface USB Host/Device SGA Output - Buzzer Alarm - PictBridge Compatible Battery Power Operation - LED Indicators - Z-Axis Input - Labiew Driver Power Source AC 100 ~ 240

6 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GDS 1000-U 100/70/50 MHz Bandwidth with 2 Input Channels 250MSa/s Real-Time and 25GSa/s Equivalent-Time Sampling 4k Memory Length per Channel Peak Detect as Fast as 10ns Save/Recall of 15 Front Panel Settings & Waveforms 5.7" TFT Color Display 19 Auto Measurements Arithmetic Operators - Add, Subtract, FFT USB Port for PC Connection Data Logger Limited Lifetime Warranty GDS-1102-U GDS-1072-U GDS-1052-U Waveform Technology - Display 5.7" TFT LCD Color Bandwidth (MHz) Number of Channel Memory Depth Sample Rate ertical Resolution ertical Sensitivity Time Base Range Input Impedance Selection 4k Points 250MSa/s (RTS) 25GSa/s (ETS) 8-bit 2m/div ~ 10/div 1ns/div ~ 50s/div Auto Measurement 19 Waveform Memory 15 Panel Setup Memory 15 Auto-Set Auto/Normal Trigger ALT Trigger - T Trigger Cursor Readout XY Mode Zoom Go/NoGo Zoom FFT - Counter Function Function Generator - Logic Analyzer - Data Logger Digital Storage Go/NoGo Output - Interface 1MΩ USB Host/Device SGA Output - Buzzer Alarm - PictBridge Compatible - Battery Power Operation - LED Indicators - Z-Axis Input - Labiew Driver Power Source AC 100 ~ 240

7 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GBS MHz/100MHz/70MHz Bandwidth Range 1GSa/s Real-time Sampling Rate and 25k Points Memory Depth 25GSa/s Equivalent Time Sampling Rate 2m /div to 5/div of ertical Range 1ns/div to 10s/div of Time Base Range 5.7 inch TFT LCD Display Data Log USB Host: Flash drive storage and PictBridge-compatible printer USB Device: PC remote control 27 Automatic Measurement Functions offer Direct Measurement Readings FFT and FFTrms Computing Provides the Frequency Domain Analysis GBS-1074 GBS-1104 GBS-1204 Channels Bandwidth DC ~ 70MHz (-3dB) DC ~ 100MHz (-3dB) DC ~ 200MHz (-3dB) Rise Time 5 ns Approx. 3.5ns Approx. 1.75ns Approx. Sensitivity 2m/div ~ 5/div (1-2-5 increments) Accuracy ±(3% x Readout div x olts/div+0.8m) Input Coupling AC, DC & Ground Input Impedance 1MΩ±2%, ~16pF Polarity Normal & Invert Maximum Input 300 (DC+AC peak), CATII Waveform Signal Process +, -,*, FFT,FFTrms Offset Range 2m/div ~ 20m/div : ±0.5 / 50m/div ~ 200m/div : ±5 / 500m/div ~ 2/div : ±50 / 5/div : ±300 Bandwidth Limit 20MHz (-3dB) Sources CH1, CH2, CH3, CH4, Line Type Edge,ideo,Pulse Modes Auto-Level, Auto, Normal, Single ideo trigger standard SECAM,PAL,NTSC Coupling AC, DC, LF rej., HF rej., Noise rej. Sensitivity DC ~ 25MHz : Approx. 0.5div or 5m / 25MHz ~70/100/ 200MHz : Approx. 1div or 10m Range 1ns/div ~ 10s/div (1-2-5 increments) / ROLL : 250ms/div ~ 10s/div Modes Main, Window, Window Zoom, Roll, Scan, X-Y Accuracy ±0.01% Pre-Trigger 20 div maximum Post-Trigger 1000 div X-Axis Input Channel 1 Y-Axis Input Channel 2,Channel3,Channel 4 Phase Shift ±3 at 100kHz Real-Time Sample Rate 1GSa/s maximum Equivalent Sample Rate 25GSa/s maximum ertical Resolution 8 Bits Record Length 25K Points maximum Acquisition Mode Normal, Peak Detect, Average Peak Detection 10ns Average 2, 4, 8, 16, 32, 64, 128, 256 oltage Measurement pp, amp, avg, rms, hi, lo, max, min, Rise Preshoot/ Overshoot, Fall Preshoot/Overshoot Time Measurement Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle Delay Measurement Eight types of delay measurement Cursors Measurement oltage difference between cursors (Δ) Time difference between cursors (ΔT) Auto Counter Resolution : 6 digits / Accuracy : ±2% / Signal Source: All available trigger source except the ideo trigger mode Autoset Automatically adjusts ertical OLTS/DI, Horizontal TIME/DI, and Trigger level Save Setup Up to 20 sets of measurement conditions Save Waveform 24 sets of waveform TFT LCD Type 5.7 inch Display Resolution 234 (ertically) x 320 (Horizontally) Dots Display Graticule 8 x 10 divisions ; 8 x 12 divisions (menu off) Display Brightness Adjustable Go/NoGo Output 5 Maximum/10mA TTL Open Collector Output RS-232 Interface DB 9-pin male DTE RS-232 interface GPIB Interface (Option) Fully programmable with IEEE compliance USB USB Host/Device 2.0 full speed supported Line oltage Range AC 100 ~ 240, 48Hz ~ 63Hz, Auto selection Multi-Language Menu Available Data Log Available Time Clock Time and Date, Provide the Date/Time for saved data DIMENSIONS & WEIGHT 310(W) x 142(H) x 254(D) mm; Approx. 4.3kg

8 SAMAR s.r.l. Web: ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy MODELLI PORTATILI SERIE PORTATILE GDS-300/ /100/70MHz Bandwidth Selections, Two Input Channels 1GSa/s Maximum Sample Rate Maximum 5M Memory Depth Per Channel x 480 Full Touch Panel Capacitive LCD Multi-Point Control, Landscape and Portrait Display Built-In 50,000 Counts DMM 30,000 Consecutive Waveform Records Logging Function, Replay Measurement Results Any Time Temperature Measurement and Logging Function Built-In Engineering Calculator, SMD Resistance Coding, Color Coding Info, and Attenuator Calculation Application Software Optional Differential Probe to Achieve Isolation Effect SERIE GDS MHz Bandwidth 100MS/s Real-Time Sampling Rate True RMS Multimeter: olt, AMp, Ohm, Continuity, Diode Dual Independent Floating Isolated Channels Trigger Mode: Free Run, Single Shot, Edge, ideo USB Interface 6 Hour Capacity Li-ion Rechargeable Battery 3.8" Color LCD, Resolution: 320 x 240 Light Weight: 690g Real-Time & Digital Storage Oscilloscopes GRS-6000A 50M/30MHz with 100MSa/s and 2 Channles Equivalent Time Sampling of 500MSa/s max. Acquire Mode : Peak Detect, Envelop, Persistence Pre-Trigger Function 0 ~ 10 div ROLL Mode to 100s/div Waveform SAE/RECALL 10 sets (REF0~REF9) Max. Sweep Rate 10ns/div Panel Setting SAE/RECALL 10 sets (M0~M9) RS-232C Interface

9 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy SERIE GOS MHz Bandwidth, Dual Channel, Delayed Sweep Built-In 6 digits Universal Counter (GOS-6103C) 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6103/GOS-6103C) Time Base Auto-range (GOS-6103/GOS-6103C) Cursor Readout with 7 Measurements Panel Setup Lock of Digital-Control Functions Buzzer Alarm LED Indicators T Synchronization Digital / Analog Display GOS-6103C GOS-6103 GOS-6112 Analog Bandwidth (MHz) " CRT Number of Channel ertical Sensitivity Time Base Range Input Impedance Selection 2m/div ~ 10/div 1ns/div ~ 50s/div Auto Measurement - Waveform Memory - Panel Setup Memory Auto-Set,Only Provided Time-Base Function. - Auto/Normal Trigger ALT Trigger - T Trigger Cursor Readout XY Mode Zoom Go/NoGo - Zoom FFT - Counter Function Function Generator - Interface - Buzzer Alarm - Battery Power Operation - LED Indicators Z-Axis Input Power Source AC 100/120/230 ±10% 1MΩ

10 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GOS-653G & GOS-652G 50MHz Bandwidth, Dual Channel Delayed Sweep (GOS-653G) Built-In Delay Line (GOS-653G) T Synchronization CH1 Output Z-Axis Modulation Input ALT Triggering Function Hold Off Function Trigger Level Lock Function Digital / Analog Display GOS-653G Analog 6" CRT GOS-652G Bandwidth (MHz) Number of Channel 2 2 ertical Sensitivity Time Base Range Input Impedance Selection 0.1μs ~ 0.5s(A) 10ns ~ 0.5s(B) 1m ~ 5 Auto Measurement - Waveform Memory - Panel Setup Memory - Auto-Set - Auto/Normal Trigger ALT Trigger T Trigger Cursor Readout - XY Mode Zoom - 1MΩ 0.1μs ~ 0.5s Delayed Sweep - Zoom FFT - Counter Function - Function Generator - Interface - Buzzer Alarm - Battery Power Operation - LED Indicators - Z-Axis Input Power Source AC 100/120/220/230 ±10%

11 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GOS-635G & GOS-622G 35MHz Bandwidth, Dual Channel (GOS-635G) 20MHz Bandwidth, Dual Channel (GOS-622G) High Sensitivity 1m/div T Synchronization Z-Axis Input ALT Triggering Function Hold Off Function (GOS-635G,GOS-622G) CH1 Output Digital / Analog Display GOS-635G Analog 6" CRT GOS-622G Bandwidth (MHz) Number of Channel 2 2 ertical Sensitivity 1m ~ 5 Time Base Range 0.1μs ~ 0.5s Input Impedance Selection 1MΩ Auto Measurement - Waveform Memory - Panel Setup Memory - Auto-Set - Auto/Normal Trigger ALT Trigger T Trigger Cursor Readout - XY Mode Zoom - Counter Function - Function Generator - Interface - Buzzer Alarm - Battery Power Operation - LED Indicators - Z-Axis Input Power Source AC 100/120/220/230 ±10%

12 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GOS-630 & GOS /20MHz Bandwidth, Dual Channel High Sensitivity 1m/div T Synchronization Z-Axis Input ALT Triggering Function CH1 Output Digital / Analog Display GOS-630 Analog 6" CRT GOS-620 Bandwidth (MHz) Number of Channel 2 2 ertical Sensitivity 1m ~ 5 Time Base Range 0.2μs ~ 0.5s Input Impedance Selection 1MΩ Auto Measurement - Waveform Memory - Panel Setup Memory - Auto-Set - Auto/Normal Trigger ALT Trigger T Trigger Cursor Readout - XY Mode Zoom - Counter Function - Function Generator - Interface - Buzzer Alarm - Battery Power Operation - LED Indicators - Z-Axis Input Power Source AC 115/230 ±15% GOS-620FG COME GOS-620 MA INCLUDE GENERATORE DI FUNZIONI built-in 1 MHz Function Generator 20MHz Bandwidth, Dual Channel High Sensitivity 1m/div ALT Triggering Function T Synchronization CH1 Output Z-Axis Input

13 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GSP-9300 ANALIZZATORI DI SPETTRO Frequency Range: 9kHz ~ 3GHz High Frequency Stability: 0.025ppm 3dB RBW: 1Hz ~ 1MHz 6dB EMI Filter: 200Hz, 9kHz, 120kHz, 1MHz Phase Noise: 10kHz Offset Built-in Measurement Functions: 2FSK Analysis, AM/FM/ASK/FSK Demodulation & Analysis, EMC Pre-test, P1dB point, Harmonic, Channel Power, N-dB bandwidth, OCBW, ACPR, SEM, TOI, CNR, CTB, CSO, Noise Marker, Frequency Counter, Time Domain Power, Gated Sweep Built-in Spectrogram and Topographic Display Modes 886MHz IF Output for User s Extended Applications Remote Control Interface: LAN, USB, RS-232, GPIB (Optional) Built-in Preamplifier, 50dB Attenuator, and Sequence Function Optional 6GHz Power Sensor, Tracking Generator, Battery Back Frequency Frequency Range 9 khz to 3.0 GHz Resolution 1 Hz Frequency Reference Accuracy ±[(period since last adjustment X aging rate) + stability over temperature + supply voltage stability Aging Rate ±2 ppm max. 1 year after last adjustment Frequency Stability over Temperature Supply oltage Stability ±0.025 ppm 0 to 50 C ±0.02 ppm Frequency Readout Accuracy Start, Stop, Center, Marker ±(marker frequency indication X frequency reference accuracy + 10% x RBW + frequency resolution *1 ) Sweep points 601 Span >= 100 Hz 6 to 601 Span = 0 Hz Marker Frequency Counter Resolution 1 Hz, 10 Hz, 100 Hz, 1 khz Accuracy ±(marker frequency indication X frequency reference accuracy + counter resolution) RBW/Span >=0.02 ; Mkr level to DNL>30 db Frequency Span Range 0 Hz (zero span), 100 Hz to 3 GHz Resolution 1 Hz Accuracy ± frequency resolution *1 Phase Noise Offset from Carrier Fc =1 GHz; RBW = 1 khz, BW = 10 Hz;Average khz <-88 dbc/hz Typical khz <-95 dbc/hz Typical 1 MHz <-113 dbc/hz Typical Resolution Bandwidth (RBW) Filter Filter Bandwidth 1 Hz to 1 MHz in sequence -3dB bandwidth 200 Hz, 9 khz, 120 khz, 1 MHz -6dB bandwidth Accuracy ± 8%, RBW = 1 MHz Nominal 3 ± 5%, RBW < 1 MHz Nominal Shape Factor < 4.5:1 Normal Bandwidth ratio: -60dB:-3dB ideo Bandwidth (BW) Filter Filter Bandwidth 1 Hz to 1 MHz in sequence -3dB bandwidth [1] Frequency Resolution = Span/(Sweep points - 1) [2] Typical specifications in this datasheet mean that the performance can be exhibited in 80% of the units with a 95% confidence level over the temperature range 20 to 30 C. They are not covered by the product warranty. [3] Nominal values indicate expected performance. They are not covered by the product warranty. Amplitude Amplitude Range Measurement Range 100 khz to 1 MHz Displayed Average Noise Level (DANL) to 18 dbm 1 MHz to 10 MHz DANL to 21 dbm 10 MHz to 3 GHz DANL to 30 dbm Attenuator Input Attenuator Range 0 to 50 db, in 1 db step Auto or manual setup Maximum Safe Input Level Average Total Power <= 33 dbm Input attenuator 10 db DC oltage ± 50 1 db Gain Compression Total Power at 1st Mixer > 0 dbm Typical;Fc 50 MHz; preamp. off Total Power at the Preamp > -22 dbm mixer power level (dbm)= input power (dbm)-attenuation (db) Displayed Average Noise Level *4 (DANL) Preamp off 0 db attenuation; RF Input is terminated with a 50 Ohm load. RBW 10 Hz; BW 10 Hz; span 500 Hz; reference level = -60dBm; trace average 40 9 khz to 100 khz, < -93 dbm 100 khz to 1 MHz, < -90 dbm - 3 x (f/100 khz) db 1 MHz to 10 MHz, < -122 dbm Nominal 10 MHz to 3 GHz, < -122 dbm Preamp on 0 db attenuation; RF Input is terminated with a 50 Ohm load. RBW 10 Hz; BW 10Hz; span 500 Hz; reference level = -60dBm; trace average khz to 1 MHz, < -108 dbm - 3 x (f/100 khz) db 1 MHz to 10 MHz, < -142 dbm Nominal 10 MHz to 3 GHz, < -142 dbm + 3 x (f/1 GHz) db

14 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy [4] DANL spec shall exclude the Spurious Response Level Display Range Scales Log, Linear Units dbm, dbm, dbu,, W Marker Level Readout 0.01 db Log scale 0.01 % of reference level Linear scale Level Display Modes Trace, Topographic, Spectrogram Single / split Windows Number of Traces 4 Detector Positive-peak, negative-peak, sample, normal, RMS(not ideo) Can be setup for each trace separately Trace Functions Clear & Write, Max/Min Hold, iew, Blank, Average Absolute Amplitude Accuracy Absolute Point Center=160 MHz ; RBW 10 khz; BW 1 khz; span 100 khz; log scale; 1 db/div; peak detector; 20 to 30 C; signal 0 dbm Preamp off ± 0.3 db Ref level 0 dbm; 10 db RF attenuation Preamp on ± 0.4 db Ref level -30 dbm; 0 db RF attenuation Frequency Response Preamp off Attenuation: 10 db; Reference: 160 MHz; 20 to 30 C 100 khz to 2.0 GHz ± 0.5 db 2.0GHz to 3.0 GHz ± 0.7 db Preamp on Attenuation: 0 db; Reference: 160 MHz; 20 to 30 C 1 MHz to 2.0 GHz ± 0.6 db 2.0GHz to 3.0 GHz ± 0.8 db Attenuation Switching Uncertainty Attenuator setting 0 to 50 db in 1 db step Uncertainty ± 0.15 db reference: 160 MHz, 10dB attenuation RBW Filter Switching Uncertainty 1 Hz to 1 MHz ± 0.25 db reference : 10 khz RBW Level Measurement Uncertainty Overall Amplitude Accuracy ± 1.5 db 20 to 30 C; frequency > 1 MHz; Signal input 0 to -50 dbm; Reference level 0 to -50 dbm; Input attenuation 10 db; RBW 1 khz; BW 1 khz; after cal; Preamp Off ± 0.5 db Typical Spurious Response Second Harmonic Intercept Preamp off; signal input -30dBm; 0 db attenuation +35 dbm Typical; 10 MHz < fc < 775 MHz +60 dbm Typical; 775 MHz fc < 1.5 GHz Third-order Intercept Preamp off; signal input -30dBm; 0 db attenuation > 1dBm 300 MHz to 3 GHz Input Related Spurious < -60 dbc Input signal level -30 dbm, Att. mode, Att=0 db; degree C Residual Response (inherent) <-90 dbm Input terminated; 0 db attenuation; Preamp off Sweep Sweep Time Range 22ms to 1000s Span >= 100 Hz 50us to 1000s Span = 0 Hz; Min Resolution = 10 us Sweep Mode Trigger Source Trigger Slope Continuous; Single Free run; ideo; External Positive or negative edge RF Preamplifier Frequency Range Gain 1 MHz to 3 GHz 18 db Nominal (installed as standard) Front Panel Input/Output RF Input Connector Type N-type female Impedance 50 ohm, nominal SWR <1.6 :1 300 khz to 3 GHz; Input attenuator 10 db Power for Option Connector Type SMB male oltage/current DC +7 / 500 ma max With short-circuit protection USB Host Connector Type A plug Protocol ersion 2.0 Supports Full/High/Low speed MicroSD Socket Protocol SD 1.1 Supported Cards MicroSD, MicroSDHC Up to 32GB capacity Rear Panel Input/Output Reference Output Connector Type BNC female Output Frequency Output Amplitude Output Impedance 10 MHz 3.3 CMOS 50 ohm Reference Input Connector Type BNC female Input Reference Frequency Input Amplitude Frequency Lock Range 10 MHz -5 dbm to +10 dbm Within ± 5 ppm of the input reference frequency Alarm Output Connector Type BNC female; Open-collector Trigger Input/ Gated Sweep Input Connector Type BNC female Input Amplitude Switch 3.3 CMOS Auto selection by function LAN TCP/IP Interface Connector Type RJ-45 Base 10Base-T; 100Base-Tx; Auto-MDIX USB Device Connector Type B plug For remote control only; supports USB TMC Protocol ersion 2.0 Supports Full/High speed IF Output Connector Type SMA female Impedance 50 ohm Nominal IF Frequency 886 MHz Nominal

15 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy Output level -25 dbm 10 db attenuation; RF input: 0 1 GHz; Earphone Output Connector Type DI-I ( integrated analog and digital), Single Link Compatible with GA or HDMI standard through adapter RS232 Interface Connector Type D-sub 9-pin female Tx,Rx,RTS,CTS GPIB Interface (Optional) Connector Type IEEE-488 bus connector AC Power Input Power Source AC 100 to 240, 50 / 60 Hz Auto range selection Battery Pack (Optional) Battery pack 6 cells, Li-Ion rechargeable, 3S2P With UN38.3 Certification oltage Capacity DC mah / 56Wh General Internal Data storage Power Consumption Warm-up Time 16 MB nominal <65 W < 30 minutes Temperature Range +5 C to +45 C Operating -20 C to + 70 C Storage Weight 4.5 kg (9.9 lb) Inc. all options (Basic+TG+GPIB+Battery) Dimensions 210 x 350 x 100 (mm) Approximately 8.3 x 13.8 x 3.9 (in) Tracking Generator *5 (Optional) Frequency Range Output Power 100 khz to 3 GHz -50 dbm to 0 dbm in 0.5 db steps Absolute Accuracy ± 0.5 MHz, -10 dbm, Source attenuation 10 db, 20 to 30 C Output Flatness Referenced to 160 MHz, -10 dbm 100 khz to 2 GHz ± 1.5 db 2 GHz to 3 GHz ± 2.0 db Output Level Switching Uncertainty ± 0.8 db Referenced to -10 dbm Harmonics < -30 dbc Typical, output level = -10 dbm Reverse Power Connector type +30 dbm max. N-type female Impedance 50 ohm Nominal Output SWR < 1.6:1 300 khz to 3 GHz, source attenuation 12 db [5] The minimum RBW filter is 10 khz when the TG output is ON. USB Power Sensor (Optional) Type Average power sensor Model: PWS-06 Interface to Meter Connector Type USB cable to GSP930 Front-Panel USB Host N-type male, 50 ohm nominal Input SWR 1.1: 1 Typical 1.3: 1 Max Input Frequency Sensing Level Max. Input Damage Power Power Measurement 25 C 1 to 6200 MHz -32 to +20 dbm <= 27 dbm -30 dbm to +5 dbm: 1 MHz to 3GHz: ±0.10 db typical ±0.30 db max. 3 GHz to 6 GHz: ±0.15 db typical ±0.30 db max. +5 dbm to +12 dbm: 1 MHz to 3GHz: ±0.15 db typical ±0.30 db max. 3 GHz to 6 GHz: ±0.15 db typical ±0.30 db max. +12 dbm to +20 dbm: 1 MHz to 3GHz: ±0.20 db typical ±0.40 db max. 3 GHz to 6 GHz: ±0.20 db typical ±0.40 db max. Power Measurement 0 to 25 C -30 dbm to +5 dbm: 1 MHz to 3GHz: ±0.25 db typical 3 GHz to 6 GHz: ±0.25 db typical +5 dbm to +12 dbm: 1 MHz to 3GHz: ±0.20 db typical 3 GHz to 6 GHz: ±0.20 db typical +12 dbm to +20 dbm: 1 MHz to 3GHz: ±0.35 db typical 3 GHz to 6 GHz: ±0.30 db typical 25 C ±3 % Measurement Speed 100 ms for Low Noise Mode Typical 30 ms for Fast Mode

16 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GSP-830 Low Noise 3k RBW) Sequence Programming Functions ACPR, OCBW, Channel Power, N-dB and Phase Jitter Measurements 10 Markers with Delta Marker, Peak Functions AC/DC/Battery(Option)three modes of power supply USB/RS-232C/GPIB(Option) Interface 6.4" TFT Color LCD, Resolution: 640x480 Optional Tracking Generator Optional Preamplifier FREQUENCY Frequency Range 9kHz ~ 3GHz Aging Rate ± 10ppm, 0~50 C, 5ppm/yr Span Range 2kHz ~ 3GHz in sequence, full span, zero span Phase Noise 20kHz offset typical Sweep Time Range 50ms ~ 25.6s RESOLUTION BANDWIDTH RBW Range 3kHz, 30kHz, 300kHz, 4MHz RBW Accuracy 15% ideo Bandwidth Range 10Hz ~ 1MHz in 1-3 steps AMPLITUDE Measurement Range -103dBm ~ +20dBm: 1MHz ~ 15MHz, -30dBm -117dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level -110dBm -114dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level -110dBm (Span = 50kHz, RBW = 3kHz) Overload Protection Max. +30dBm, ±25DC Reference Level Range -110dBm ~ +20dBm Accuracy Frequency Flatness ±1dB Display Range Linearity ±1dB over 70dB DYNAMIC RANGE Average Noise Floor Third Inter-Modulation Harmonic Distortion Non-Harmonic Spurious GENERAL Display Split Windows Markers Trace Detection Power Measurement Autoset Function Trigger <-135±1dBm/Hz: 1MHz ~ 15MHz, -30dBm <-149dBm/Hz, typical -152dBm/Hz: 15MHz ~ 1GHz, Ref.Level -110dBm <-146dBm/Hz, typical -149dBm/Hz: 1GHz ~ 3GHz, Ref.Level -110dBm <-70dBc RF <-60dBc RF Input <-40dBm Typical, <-93dBm, 1MHz ~ 15MHz, <-107dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level -110dBm <-104dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level -110dBm (Span = 50kHz, RBW = 3kHz) 640 x 480 high resolution TFT color LCD Active Window: Upper, Lower or Alternate (two simultaneously sweeping windows) 10 Markers for peaks: 5 normal-delta marker pairs Functions: Delta, To Peak, To Minimum, Peak Track, Peak Table, Peak Sort 3 traces with Peak, Maximum hold, Freeze, Average, Trace math ACPR, OCBW, Channel Power, N db and Phase Jitter Auto tuning the measurement result for observation Conditions: ideo, External (Positive-going, +5 TTL external signal) Mode: Normal, Single, Continuous Sequence CONNECTORS RF Input External Reference Clock Input Reference Clock Output DC Input (DC Power Operation) DC Output (for GAP-801) INTERFACE RS-232C USB Connector GA Output Option: GPIB Interface POWER SOURCE ACCESSORIES DIMENSIONS & WEIGHT Automated test by user-defined macros without any remote controller, 10 Sequential macro set and 10 macros per each set, ariable delays and wait-to-go facilitate automated measurement, Do-sequence links and nests different sequence sets. N female, 50Ω nominal RF input SWR: Reference Level Type: BNC female 1M, 1.544M, 2.048M, 5M, 10M, 10.24M, 13M, 15.36M, 15.4M, 19.2MHz Type: BNC female, 10MHz Jack : 5.5mm, 12 Type: SMB Male, outputs +9/100mA Max. Sub-D 9 pins female USB Host/Device full speed supported Front panel: Type A receptacle for USB flash devices Fully programmable with IEEE compliance AC 100 ~ 240, 50/60Hz User Manual x 1 Power Cord x 1 USB Cable (Type A plug to Type mini-b plug) x1 330(W) x 170(H) x 340(D) mm Approx. 6kg

17 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GSP-730 Frequency Range : 150kHz ~ 3GHz Autoset Function Noise Floor: -100dBm RBW Range : 30kHz, 100kHz, 300kHz, 1MHz ACPR/CHPW/OCBW Measurement 3 Traces in Different Colors Split Window Function Limit Line Function Remote Control Software Presentation Material for Training Courses Support Interface : USB Device/Host, RS-232C 5.6 TFT LCD with GA Output requency Frequency Range Setting Range 150kHz to 3GHz Center Frequency Setting Resolution 0.1MHz Accuracy within ±50kHz (frequency span : 0.3GHz to 2.6GHz, 20 ±5 C) Frequency Span Setting range 1MHz to 3GHz Accuracy within ±3% (frequency span : 0.3GHz to 2.6GHz, 20 ±5 C) Resolution Bandwidth Setting Range 30KHz, 100KHz, 300KHz,1MHz, SSB Phase Noise -85dBc / Hz (typical, 500kHz offset, RBW : 30kHz, Sweep time: 1.5s, Inherent Spurious Response less than -40dBm Ref. Level (typical less than -50dBc) Amplitude Reference Level Average Noise Level Frequency Characteristic Input Sweep Sweep Time Setting Range Accuracy General Communication Display Interface RS-232C USB Connector GA Output Power Source Other Input Range Unit +20 to -40dBm dbm, db, dbµ -100dBm (typical, center frequency : 1GHz RBW : 30kHz) Accuracy : Within ±2dB (1GHz);SPAN:5MHz; Ref. Level 0dBm, input signal -10dBm; within within 80~300MHz, 2.6~3GHz Input Impedance Input SWR Input damage level Input connector 300ms to 8.4s, auto (not adjustable) within ±2% ( frequency span : full span) 640*480 RGB color LCD Sub-D female-d 9 pins USB Host/Device full speed supported Sub-D female 15 pins AC 100~240, 50/60Hz 50ohm less than att 10dB +30dBm (CW average power), 25DC N connector Operating 5 to 45 C (Guaranteed at 25 ±5 C, without soft carrying case) Temperature Operating Humidity Less than 45 C / 90%RH Storage Temperature -20 to 60 C, less than 60 C / 70%RH Dimensions 296 (L) 153 (W) 105 (H) mm Weight Approx. 2.2kg A RICHIESTA TRAINER PER LO STUDIO DI SISTEMI RF

18 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GSP-810 Frequency Range: 150kHz ~1GHz Fully Digital Phase Locked Loop Technique Design High Frequency Stability:±10ppm RBW : 3K, 30k, 220k, 4MHz High Input Protection Level : +30dBm,±25DC Reference Level Range : -30dBm~ +20dBm Two Markers for Absolute and Relative Measurement Support standard RS-232C Interface to connect with PC Options: Tracking Generator, Power Meter, Remote Control Software FREQUENCY Frequency Range Aging Rate Span Range Phase Noise Frequency Resolution Frequency Display Frequency Control RESOLUTION BANDWIDTH RBW Range RBW Accuracy 15% ideo Bandwidth Range AMPLITUDE Measurement Range Overload Protection Reference Level Range Amplitude Display Range Amplitude Accuracy Frequency Flatness Amplitude Level Linearity DYNAMIC RANGE 150kHz~1GHz ± 10ppm, 0~50 C, 2ppm/yr Zero, 2kHz~100MHz/div in sequence 1GHz 30kHz offset 1kHz C.F. entry, 40Hz sweep resolution at 2kHz/div 6 1/2 digit setting Digital phase locked 3kHz, 30kHz, 220kHz, 4MHz 1.6kHz/90kHz couple with RBW -100dBm~+20dBm +30dBm continuous, ± 25DC -30dBm~+20dBm 75dB ±1.5dB 0dBm, 80MHz ±1.5dB over 100MHz,±2.5dB typical over entire band/±3db:150khz~10mhz ± 1.5dB over 70dB Average Noise Floor RBW, -100dBm typical / -75dBm: 150kHz~10MHz Third Inter-Modulation Harmonic Distortion Non-Harmonic Spurious DISPLAY SYSTEM Display Device Display Function FUNCTIONS Marker Mode Number of Markers 2 Marker Resolution Marker Accuracy Memory Trace Setup Demodulator Calibrate Signal Interface POWER SOURCE AC ACCESSORIES DIMENSIONS & WEIGHT input, 2tones, 2MHz apart/ <-45dBc:150kHz~10MHz <-40dBc, RF input < selected reference <-60dBc typical down from reference level, average, 5MHz/div CRT Display, 8 x 10 graticule, 6-inch waveform screen LCD Display, 4 line x 20 character data screen Center Frequency Control, Bandwidth, Reference Level, Span Range, Amplitude Absolute, relative, PK->marker, marker->center 0.1dB, 1kHz 0.1dB±amplitude accuracy 10 save/recall memory Max. hold, average(2~32 traces), freeze(hold) Access parameters WB FM, 120kHz deviation MB FM, 75kHz deviation NB FM, 30kHz deviation AM Outputs : Internal speaker, 3.5mm stereo jack, wired for mono operation 80MHz, -30dBm RS-232C standard & remote display software (The software will be downloaded from GW Web-Site.) 100/120/220/230 ±10%, 50/60Hz User manual x 1, Power cord x 1 310(W) x 150(H) x 455(D) mm Approx. 8.5kg

19 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy ALIMENTATORI PER LABORATORIO ALIMENTATORI ALTA TENSIONE Sorgente di alta tensione flottante, ad impiego universale, per il funzionamento di tubi elettronici. Con trasformatore incorporato resistente alle alte tensioni, che consente di prelevare la tensione di riscaldamento necessaria per azionare i tubi elettronici. Alta tensione a regolazione continua, non pericolosa, con limitazione della corrente passiva e display analogico della tensione. Collegamenti: jack di sicurezza da 4 mm Alimentazione: ca ± 10% 50/60Hz Dimensioni: 132x170x270 mm peso 2Kg tipo uscita alta tensione uscita tensione di riscaldamento opzione SM10-H10000A /10 ma 6,3 / 3 A SM10-H6000A /3 ma 6,3 / 3 A SM10-H5000A /2 ma 6,3 / 3 A ALIMENTATORI STABILIZZATI ALIMENTATORE REGOLABILE CC 0-30 / 0-5 A TIPO SMAQL5A Alimentazione 110AC/220AC±10% a 50/60Hz Disponibile anche nella versione 0-30 / 0-3 A ALIMENTATORE SWITCHING REGOLABILE CC 0-30, 0-5 A TIPO SMAL30S Alimentazione 110AC/220AC±10% a 50/60Hz disponibile anche versione 0-30, 0-3 A ALIMENTATORE CON DISPLAY LCD - alimentatore 0-30 / 0-1A con display LCD SMAL31C - alimentatore 0-30 / 0-2A con display LCD SMAL32C - alimentatore 0-30 / 0-3A con display LCD SMAL33C ALIMENTATORE CON DISPLAY A LED - alimentatore 0-30 / 0-1A con display LED SMAL31L - alimentatore 0-30 / 0-3A con display LED SMAL33L ALIMENTATORE REGOLABILE CC 0-30/ 0-20 A TIPO M10-SP-3020E LED Alimentazione 110AC/220AC±10% a 50/60Hz disponibile anche versione 0-30/ 0-10 A

20 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy ALIMENTATORE STABILIZZATO SINGOLO ALIMENTATORE STABILIZZATO DUALE ALIMENTATORE STABILIZZATO TRIPLO ALIMENTATORE STABILIZZATO QUADRUPLO

21 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy ALIMENTATORI PROGRAMMABILI

22 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy ALIMENTATORI AC / DC AC / DC breadboard power supply Tipo SMSPN15-05 Uscita CC regolabile 0~+15/500mA / 0~-15/500mA Uscita CC fissa +5/1 A / -5/500mA Uscita CA fissa , 300mA Dimensioni: 150(W) 115(H) 200(D) Peso: 3kg Tipo SM10-AD350M-5 Uscita CA fissa : 1, 2, 3, 4, 5, 6, 7, 8,9, 10, 11, 12, 13,14,15 / 5 A Tipo SM10-AD350M-10 Uscita CA fissa : 1, 2, 3, 4, 5, 6, 7, 8,9, 10, 11, 12, 13,14,15 / 10 TIPO AL 30/5 Uscita AC / DC regolabile e selezionabile da interruttore Display digitale indicazione tensione e corrente erogate Uscita CC radrizzata regolabile 0-30/5 A protezione da fusibile Uscita CA regolabile 0-30 / 5 A protezione da fusibile Disponibili diverse versioni personalizzate con tensioni e correnti elevate AL30/5 AL 24/15 AL60/10 ALIMENTATORE CA ARIABILE MONOFASE Uscita CA /2 0 5 A Display digitale indicazione tensione e corrente erogate Disponibile anche mono-trifase Disponibili diverse versioni personalizzate con tensioni e correnti elevate ALIMENTATORE CA USCITE FISSE MONOFASE TRIFASE CON PROTEZIONI Disponibili vari modelli personalizzati a richiesta del cliente

23 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GDM-8261A 6 1/2 Digit Display:1,200,000 counts DC Basic Accuracy:0.0035% Dual Measurements to perform two selected measurements simultaneously Bright acuum Fluorescent Display (FD) Provide AC+DC oltage or Current Measurement Functions 11 Measurement Functions & 10 Math Functions High Resolution: Up to 100pA with DCI and 1nA with ACI Measurements Temperature Measurement (RTD & Thermocouple) from -200 C ~ C High Transmission Speed: Up to 2,400 readings/sec through the USB Standard Interfaces : USB, RS232C, Digital I/O Free PC software : DMM iewer, LabIEW Driver Optional Interfaces : GPIB or LAN ; Optional Scanner Card : GDM-SC1 ( ch x16, I ch x2) MULTIMETRI Function Range(3) Resolution Input Resistance etc. 24 Hour 23 C± 1 C 90 Day 23 C± 5 C 1 Year 23 C± 5 C Temperature Coefficient 0 ~ 18 C /28 ~ 55 C m 0.1μ 10MΩ or >10GΩ μ 10MΩ or >10GΩ DC oltage μ 11.11MΩ±1% m 10.1MΩ±1% m 10.1MΩ±1% Ω 100μΩ 1 ma kω 1mΩ 1 ma kω 10mΩ 100μA Resistance(4) kω 100mΩ 10μA MΩ 1μΩ 3.5μA MΩ 10Ω 350nA MΩ 100Ω 350 na//10 MΩ μa 100pA < ma 1nA < DC Current ma 10nA < m A 0.1μA < A 1μA < A 10μA < Continuity Ω 0.001Ω 1 ma Diode Test μ 1 ma Hz - 5Hz Hz - 10Hz m 0.1μ 10Hz - 20kHz kHz - 50kHz kHz - 100kHz True RMS AC oltage(6) 100kHz -300kHz Hz - 5Hz Hz - 10Hz to (5) 1μ ~ 1m 10Hz - 20kHz kHz - 50kHz kHz - 100kHz kHz -300kHz Hz 5Hz ma 1nA 5Hz 10Hz Hz 5kHz kHz 10kHz Hz 5Hz ma 10nA 5Hz 10Hz Hz 5kHz True RMS AC Current(6) ma 100nA A 1μA A 10μA 5kHz 10kHz Hz 5Hz Hz 10Hz Hz 5kHz kHz 10kHz Hz 5Hz Hz 10Hz Hz 5kHz kHz 10kHz Hz 5Hz Hz 10Hz Hz 5kHz kHz 10kHz Hz - 5Hz Frequency / Period m to (5) 5Hz - 10Hz Hz - 40Hz Hz -300kHz Temperature (RTD) -200 C ~ 600 C C 0.06 C (typical) C / C (typical) Temperature (Thermocouple) -200 C ~ C C E / J / T / K / N 0.3 C (typical) C / C (typical) -50 C ~ C 0.01 C R / S / B 1 C 0.14 C / C Display FD, Tow Colors Display Note : Interface RS -232C, USB, Digital I/O 1. All specifications are ensured only under a single display. Power Source AC 100 / 120 / 220 / 240 ±10% 2. Accuracy : ± (% of reading + % of range) Power Line Frequency 45 Hz to 66 Hz and 360 Hz to 440 Hz 3. 20% overrange on all ranges, except 1000dc, 750ac and 10A. Power Consumption Max. 25A 4. Resistance is for 4-wire ohms function, or 2-wire ohms with REL on. Dimensions 265(W) x 107(H) x 350(D) mm ac range limited to 100kHz Weight Approx. 3.1kg without option 6. AC Characteristics are for sinewave input > 5% of range.

24 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GDM-8255A GDM-8255A 199,999 Counts Display FD Two Colors Display 0.012% DC Accuracy True RMS (AC, AC+DC) 9 Major Measuring Functions and 10 Advanced Measurement Functions 2W/4W Resistance Measurement High oltage 1000 and 10A Current Range Standard Interface : RS-232C, USB Device, Digital I/O Free PC Software (DMM-IEWER), LabIEW Driver Optional: 16+2 Channels Scanner Card GDM-8255A FULL SCALE 199,999 Counts SAMPLAE RATE Slow Medium Fast 5 1/2 digits, 10 readings/second 4 1/2 digits, 30 readings/second 3 1/2 digits, 60 readings/second DC OLTAGE Range Accuracy Input Impedance 100m, 1, 10, 100, ranges ±(0.012% rdg + 5 digits) 10MΩ AC OLTAGE True RMS Range Accuracy 100m, 1, 10, 100, ranges 20Hz~45Hz : ±(1% rdg digits) 45Hz ~ 10kHz : ±(0.2% rdg digits) 10kHz ~ 30kHz :±(1% rdg digits) 30kHz~100kHz : ±(3% rdg digits) Input Impedance 1.1MΩ in parallel with approx. 100pF DC CURRENT Range Accuracy 10mA, 100mA, 1A, 10A 4ranges 10mA, 100mA : ±(0.05% rdg + 15 digits) 1A, 10A range : ±(0.2% rdg + 5 digits) AC CURRENT True RMS Range Accuracy 10mA, 100mA, 1A, 10A 4ranges 10mA, 100mA range: 20Hz ~ 50Hz : ±(1.5% rdg digits) 50Hz ~ 10kHz : ±(0.5% rdg digits) 10kHz~20kHz : ±(2% rdg digits) 1A, 10A range: 50Hz~10kHz : ±(1% rdg digits) RESISTANCE Range 2W Accuracy 100Ω, 1kΩ, 10kΩ, 100kΩ, 1MΩ, 10MΩ, 100MΩ 7 ranges 100Ω range : ±(0.1% rdg + 8 digits)(*) 1kΩ range : ±(0.08% rdg + 5 digits)(*) 10kΩ ~ 1MΩ 3 ranges : ±(0.06% rdg + 5 digits) 10MΩ range : ± (0.3% rdg + 5 digits) 100MΩ range : ±(3% rdg + 8 digits) 4W Accuracy 100Ω range : ±(0.05% rdg + 8 digits) 1kΩ ~ 1MΩ 4 ranges : ±(0.05% rdg + 5 digits) 10MΩ range : ±(0.3% rdg + 5 digits) 100MΩ range : ±(3% rdg + 8 digits) DIODE TEST Open Circuit oltage 2.0 Test Current 0.5mA FREQUENCY 10Hz~800kHz CONTINUITY BEEPER 1 ~ 1000Ω Define by user TEMPERATURE 0 C ~ 300 C : J, K, T Type OTHER FUNCTIONS Auto range / Manual, Math : MX + B/ % / 1/X Max, Min, dbm, db, REL, Hold, Compare, Store, Recall DISPLAY FD, Two Colors Display INTERFACE Digital I/O, USB Device, RS-232C POWER SOURCE AC ±10%, 50/60Hz OPTIONAL GDM-SC1 : Multi-channels (16+2) Scanner Card (Up to 2 sets of GDM-SC1 can be installed at same time for one GDM-8255A) DIMENSIONS & WEIGHT 265(W) x 107(H) x 350(D) mm Approx. 2.6 kg Note : (*)USE "REL" Mode

25 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GDM ,000 counts, FD display Dual measurement/dual display The basic precision of DC voltage: 0.012% Selectable measurement speeds, the maximum: 320 Readings/s True RMS (AC,AC+DC) measurements Auto/manual selection 12 different measurement functions: AC/DC voltage, AC/DC current, AC+DC voltage/current, 2W/4W resistance, continuity beeper, diode test, capacitance, frequency, temperature Many auxiliary functions: Max./Min., REL/REL#, Compare, Hold, db, dbm, Math (MX+B, %, 1/X) Digital I/O provides dual mode (standard Compare and User definition modes) Standard RS-232C and USB device interface (support USBCDC and USBTMC modes) Range (*2) Resolution Input Resistance etc. Accuracy(*3) 1 Year (23 C±5 C) DC oltage m 1μ 10MΩ or >10GΩ μ 10MΩ or >10GΩ μ 11.1MΩ m 10.1MΩ m 10MΩ Resistance Ω 1mΩ 1mA kω 10mΩ 1mA kω 100mΩ 100μA kω 1Ω 10μA MΩ 10Ω 1μA MΩ 100Ω 0.5μA MΩ 1kΩ 0.5μA //10 MΩ DC Current ma 100nA 1Ω ma 1μA 1Ω A 10μA 0.1Ω A 100μA 0.01Ω Continuity Ω 10mΩ 1mA Diode Test μ Capacitance nf 0.01nF 10μA nf 0.1nF 10μA μf 0.001μF 100μA μf 0.01μF 1mA μf 0.1μF 1mA True RMS AC (or AC+DC AC Coupled) oltage 20Hz 45Hz m 1μ 45Hz 10kHz kHz 30kHz kHz 100kHz Hz 45Hz μ 45Hz 10kHz kHz 30kHz kHz 100kHz Hz 45Hz μ 45Hz 10kHz kHz 30kHz kHz 100kHz Hz 45Hz m 45Hz 10kHz kHz 30kHz kHz 100kHz Hz 45Hz m 45Hz 10kHz kHz 30kHz kHz 100kHz True RMS AC (or AC+DC AC Coupled) Current 20Hz 45Hz ma 100nA 45Hz 2kHz kHz 10kHz Hz 45Hz ma 1μA 45Hz 2kHz kHz 10kHz A 20Hz 45Hz μA 45Hz 2kHz kHz 10kHz A 100μA 20Hz 45Hz Hz 2kHz kHz 10kHz Frequency (oltage)10hz 1MHz (Current)20Hz 10kHz Temperature (Thermocouple) -200 C ~ 0 C 0.01 C 0.4 C (typical) J / T / K 0 C ~ +300 C 0.2 C (typical) Display FD, Tow Colors Display Interface RS-232C, USB device (USBCDC & USBTMC) Power Source AC 100 / 120 / 220 / 240 ±10%, 50-60Hz ; Power Consumption Max. 15A Dimensions & Weight 265(W) x 107(H) x 302(D) mm ; Approx. 2.9kg 1. All specifications are applicable to the main (1st) display only and warmed up for at least 30 minutes and operated in the slow rate % overrange on all ranges, except 750/10A range 3. Accuracy: ± (% of Reading + Digits)

26 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GDM-8342 & GDM ,000 counts, FD display Dual measurement/dual display Selectable measurement speeds, the maximum: 40 Readings/s for DC The basic precision of DC voltage: 0.02% Auto/manual Ranging True RMS (AC,AC+DC) measurements 11 different measurement functions Max./Min., REL, MX+B, 1/X, Ref%, Compare, Hold, db, dbm Standard USB device interface to connect with a computer Temperature measurement function (GDM-8342 only) USB storage for Data collection (GDM-8342 only) Optional GPIB (factory install for GDM-8342) Function Range (*2) Resolution Input Resistance etc. Accuracy(*1) 1 Year 23 C±5 C m 10μ 10MΩ or >10GΩ μ 10MΩ or >10GΩ DC oltage m 11.11MΩ m 10.1MΩ m 10MΩ Ω 10mΩ 0.83mA (*3) kω 100mΩ 0.83mA (*3) Resistance kω 1Ω 83μA kω 10Ω 8.3μA MΩ 100Ω 830nA MΩ 1kΩ 560nA//10 MΩ μa 10nA 0.06 max ma 100nA 0.6 max DC Current ma 1μA 0.14 max m A 10μA 1.4 max A 100μA 0.5 max A 1mA 0.8 max Continuity Ω 100mΩ 0.83mA Diode Test μ 0.83mA nf: 0.5~1nF 0.001nF 8.3μA nf: 1~5nF 0.001nF 8.3μA nf: 5~10nF 0.01nF 8.3μA Capacitance nf: 10~50nF 0.01nF 8.3μA nf 0.1nF 83μA μf 1nF 0.56mA μf 10nF 0.83mA Hz 50Hz m 10μ 50Hz 10kHz kHz 30kHz kHz 100kHz True RMS olatge AC (or AC+DC) (*4/*5/*6) True RMS Current AC (or AC+DC) (*4/*5/*6) Frequency 30Hz 50Hz μ 50Hz 10kHz kHz 30kHz kHz 100kHz Hz 50Hz m 50Hz 10kHz kHz 30kHz kHz 100kHz Hz 50Hz m 50Hz 10kHz kHz 30kHz kHz 100kHz Hz 50Hz m 50Hz 10kHz kHz 30kHz kHz 100kHz Hz 50Hz μa 10nA 50Hz 2kHz kHz 5kHz kHz 20kHz Hz 50Hz ma 100nA 50Hz 2kHz kHz 5kHz kHz 20kHz Hz 50Hz ma 1μA 50Hz 2kHz kHz 5kHz kHz 20kHz Hz 50Hz ma 10μA 50Hz 2kHz kHz 5kHz kHz 20kHz A 100μA 30Hz 50Hz Hz 2kHz A 1mA 30Hz 50Hz Hz 2kHz Hz 500Hz Hz 500kHz kHz 1MHz Temperature (*7) (Thermocouple) -200 C ~ +300 C 0.1 C J / T / K 2 C (typical) Display FD, Tow Colors Display Interface USB Device, USB Host (for GDM-8342 only), GPIB (optional for GDM-8342 only) Power Source AC 100 / 120 / 220 / 240 ±10%, 50-60Hz Power Consumption Max. 15A Dimensions Weight 265(W) x 107(H) x 302(D) mm Approx. 2.9kg without option 1. Accuracy = +/- (% of reading + digits) 2. 2% overrange on all ranges, except 10A is 20% overrange 3. REL function is on 4. The AC+DC is in AC coupled 5. The accuracy of AC+DC is equal to AC with 10 more digits added 6. AC characteristics are for sinewave input > 5% of range 7. Specifications do not include probe accuracy

27 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy MULTIMETRO DIGITALE DA BANCO TIPO M9803R Completo di interfaccia RS232, software di gestione e cavo di collegamento a pc Misure in true RMS Ampio display LCD retroilluminato 4000 punti e bargraph 42 segmenti. Funzione di Hold Autoranging e selezione manuale Memorizzazione dei valori di min e max Autospegnimento Prova continuità e prova diodi Protezione contro transienti di tensione fino a 6K Alimentazione da rete o batterie ( 6 pile 1,5 tipo AA) Dimensioni: 238x230x83 (lxpxh) Peso: 1,3Kg Completo di puntali, maniglia, cavo di alimentazione e manuale d uso CARATTERISTICHE TECNICHE FUNZIONE RANGE PRECISIONE Tensione cc ( risoluzione 0,1m) 400m 4, 40, 400, 1000 ± (0,3% + 2 digits) ± (0,1% + 2 digits) Tensione ac ( risoluzione 1m) 4, 40, 400, HZ 40Hz ~ 1KHz ± (0,5% + 5 digits) ± (1% + 5 digits) Corrente cc (risoluzione 1µA / 4mA) 4, 40, 400 ma, 10 A ( 20 A per 30 secondi) ± (0,4% + 2 digits) ± (0,8% + 4 digits) Corrente ac 40Hz ~1KHz (risoluzione 1µA / 4mA) 4, 40, 400mA, 10 A ( 20 A per 30 secondi) ± (1% + 5 digits) Resistenze (risoluzione 0,1 Ω) 400Ω 4, 40, 400 KΩ 4 MΩ 40 MΩ Prova Diodi Test current 0.6mA Tensione a circuito aperto 3.0 max Protezione di ingresso 600 rms Capacità ( risoluzione 1pF nei 4 nf ranges) 4, 40, 400nF, 4, 40 µf Temperatura ( risoluzione 1 C) Fino a 750 C Frequenza (risoluzione 0,01 Hz nei 100Hz di range) 100Hz, 1, 10, 100KHz, 1MHz ± (0,4% + 4 digits) ± (0,4% + 2 digits) ± (0,6% + 3 digits) ± (1,5% + 5 digits) GDM-8145 ast Measuring Function : AC/ DC oltage, AC/DC Current, Resistance and Diode Test Large 0.5" Red LED Display High Resolution 10μ, 10nA and 10mΩ All Range with Protection Circuit 0.03% DC Accuracy Auto Zero Circuit 20A High Current Range 1000 High oltage Range AC or AC + DC True R.M.S.

28 SAMAR s.r.l. Web: ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy GDM-400 & GDM-300 SELECTION GUIDE MODEL Max. Display Auto Ranging Analog Bar True RMS Display Backlight Fused 10A Range Auto Power off DC oltage AC oltage DC Current AC Current Resistance Capacitance Frequency Diode Continuity Temperature Duty Cycle(%) Transistor (hfe) EF Function REL Data Hold Peak Hold MAX MIN RS232C SPECIFICATIONS DC OLTAGE Range Best Accuracy Input Impedance AC OLTAGE Range Best Accuracy Input Impedance DC CURRENT Range Best Accuracy GDM A 10A 220MΩ 220mF 220MHz NEW GDM A 10A 20MΩ 20µF 20kHz GDM A 10A 40MΩ 4000µF 10MHz NEW GDM A 10A 60MΩ 4000µF 10MHz NEW GDM m, 2.2, 22, 220, 1000(GDM-461); 200m, 2, 20, 200, 600(GDM-452) / 40m, 400m, 4, 40, 400, 1000(GDM-397); 60m, 600m, 6, 60, 600, 1000(GDM-360) 400m, 4, 40, 400, 1000(GDM-398) 200m, 2, 20, 200, 600(GDM-357) 200m, 2000m, 20, 200, 250(GDM-350B) ±(0.1%rdg + 2 digits) for GDM-461; ±(0.05%rdg + 3 digits) for GDM-452 ±(0.5%rdg + 1 digit) for GDM-397/360/398/357; ±(0.5%rdg + 2 digits) for GDM-350B 10 MΩ (3000MΩ for m range of GDM-461/397/360/398) 220m, 2.2, 22, 220, 750(GDM-461); 200m, 2, 20, 200, 600(GDM-452) 40m, 400m, 4, 40, 400, 750(GDM-397); 400m, 4, 40, 400, 750(GDM-398) 60m, 600m, 6, 60, 600, 750(GDM-360); 2, 20, 200, 600(GDM-357) 200, 250(GDM-350B) ±(0.8%rdg + 10 digits) for GDM-461; ±(0.5%rdg + 10 digits) for GDM-452 ±(1.0%rdg + 3 digits) for GDM-397/360/398; ±(0.8%rdg + 3 digits) for GDM-357 ±(1.2%rdg + 3 digits) for GDM-350B 10 MΩ (3000MΩ for m range of GDM-461/397/360/398; 4.5MΩ for GDM-350B) 220µA, 2200µA, 22mA, 220mA, 10A(GDM-461); 2mA, 20mA, 200mA, 10A(GDM-452) 400µA, 4000µA, 40mA, 400mA, 4A, 10A(GDM-397/398) 600μA, 6000μA, 60mA, 600mA, 6A, 10A(GDM-360) 2mA, 20mA, 200mA, 10A(GDM-357); 2000µA, 20mA, 200mA, 10A(GDM-350B) ±(0.5%rdg + 10 digits) for GDM-461; ±(0.5%rdg + 5 digits) for GDM-452 ±(1.0%rdg + 2 digits) for GDM-397/398/350B; ±(1.0%rdg + 3 digits) for GDM-360 ±(0.8%rdg + 1 digit) for GDM A 10A 40MΩ 4000µF 10MHz NEW GDM GDM-350B A 10A 20MΩ 200µF A 20MΩ

29 ia della Pace n. 25 Fr. Zivido San Giuliano Milanese - Milano Italy AC CURRENT Range Best Accuracy RESISTANCE Range Best Accuracy CAPACITANCE Range Best Accuracy FREQUENCY Range Best Accuracy DIODE TEST Open Circuit oltage 220µA, 2200µA, 22mA, 220mA, 10A(GDM-461); 2mA, 20mA, 200mA, 10A(GDM-452) 400µA, 4000µA, 40mA, 400mA, 4A, 10A(GDM-397/398) 600μA, 6000μA, 60mA, 600mA, 6A, 10A(GDM-360); 20mA, 200mA, 10A(GDM-357) ±(0.8%rdg + 10 digits) for GDM-461/452; ±(1.0%+3) for GDM-357 ±(1.2%rdg + 5 digits) for GDM-397/360/ Ω ~ 220MΩ 7 ranges(gdm-461); 200Ω ~ 20MΩ 6 ranges(gdm-452/357/350b) 400Ω ~ 40MΩ 6 ranges(gdm-397/398); 600Ω ~ 60MΩ 6 ranges(gdm-360) ±(0.5%rdg + 10 digits) for GDM-461; ±(0.3%rdg + 1 digit) for GDM-452 ±(1.0%rdg + 2 digits) for GDM-397/360/398/357; ±(0.8%rdg + 5 digits) for GDM-350B 22nF, 220nF, 2.2µF, 22µF, 220µF, 2.2mF, 22mF, 220mF(GDM-461) 20nF, 200nF, 2μF, 20μF(GDM-452); 2nF, 20nF, 200nF, 2μF, 200μF(GDM-357) 40nF, 400nF, 4µF, 40µF, 400µF, 4000µF (GDM-397/360/398) ±(3.0%rdg + 5 digits) for GDM-461; ±(4.0%rdg + 20 digits) for GDM-452 ±(3.0%rdg + 5 digits) for GDM-397/360/398; ±(4.0%+3) for GDM Hz ~ 220MHz(GDM-461); 1Hz ~ 20kHz(GDM-452) 10Hz ~ 10MHz(GDM-397/360/398); ±(0.01%rdg + 5 digits) for GDM-461; ±(1.5%rdg + 5 digits) for GDM-452 ±(0.1%rdg + 4 digits) for GDM-397/360/398 GDM-461/452/397/360/398/357/350B : 2.8 (Approx.) GDM-350B : 2.3 (Approx.) CONTINUITY BEEPER Buzzer sounds if conductance less than 10Ω for GDM-461/397/357/360/398/350B Buzzer sounds if conductance less than 30Ω for GDM-452 TEMPERATURE Range -40ºC ~ 1000ºC Best Accuracy ±(1.2%rdg + 4 digits) for GDM-397; ±(1.0%rdg + 7 digits) for GDM-357 ±(1.0%rdg + 3 digits) for GDM-350B SPECIAL FUNCTION Auto Ranging (GDM-461/397/360); True RMS (GDM-461/360); RS-232C (GDM-461/397/360) hfe Test (GDM-398/350B); Display Backlight (GDM-397/360/398); EF Function (GDM-398) Analog Bar (GDM-461/397/360/398); Auto Power Off (GDM-452/397/357/360/398) LCD DISPLAY counts (GDM-461), 4 1/2 digits (GDM-452), 6000 counts (GDM-360) 3 3/4 digits (GDM-397/398), 3 1/2 digits (GDM-357/350B) POWER SOURCE Single 9 Battery (6F22) DIMENSIONS & WEIGHT 87(W) x 180(H) x 47(D) mm, Approx. 370g (GDM-461/397/360/398) 91(W) x 186(H) x 39(D) mm, Approx. 300g (GDM-452/357) 72(W) x 137(H) x 35(D) mm, Approx. 200g (GDM-350B) MULTIMETRO DIGITALE CON TRUE RMS E INTERFACCIA USB E WIRELESS DMBUSB1 Multimetro multifunzione digitale per misure di tensione e corrente AC/DC, Resistenza, Capacità, Frequenza (elettrica ed elettronica), Duty cicle, Test diodi, Termocoppia e Temperatura, può anche archiviare e richiamare le misurazioni effettuate. Progettato e costruito con materiali resistenti all acqua e alla polvere (IP67); estremamente versatile, permette di trasferire le misurazioni sia tramite collegamento fisico ad un PC o direttamente mediante collegamento Wireless MULTIMETRO DIGITALE CON INTERFACCIA USB DMBUSB Multimetro digitale con gamma automatica, counts Display retroiiluminato: 4 1/2 digit LCD e barra grafica a 46 segmenti. Protezione contro sovraccarico: Protezione con PTC per le misure di resistenza, capacità e frequenza. Funzione di mantenimento dei dati DATA HOLD Funzione di misura del valore MAX/MIN Selezione modo di misura AUTO/MANUAL Indicazione batteria scarica Misura del valore reale True-RMS per tensione AC e corrente AC. Funzione di misura del valore relativo Interfaccia USB di comunicazione con un PC. Funzione di autospegnimento dopo circa 15 minuti di inattività dello strumento. Per disabilitare questa funzione, accendere lo strumento tenendo premuto un pulsante funzione, eccetto il pulsante HOLD. Alimentazione: 4 Batterie (formato AA) 1.5 Dimensioni (L x W x H) & Peso: 205 x 102 x 58mm, circa 390g. Accessori in dotazione: Cavetto USB - CD con programma per interfaccia USB Funzione Gamma Risoluzione Precisione Tensione DC 2.2/22/220/ m ±(0.05%rdg+3dgt) Tensione AC (40-400HZ) 2.2/22/220/ m ±(0.8%rdg+4dgt) DC m 220m 0.01m ±(0.05%rdg+3dgt) AC m (40-400HZ) 220m 0.01m ±(0.8%rdg+4dgt) Corrente DC 220µ/2200µ/22m/220m/10A 0.01µ ±(0.8%rdg+4dgt) Corrente AC (40-400HZ) Resistenza Capacità Frequenza Prova di continuità 220µ/2200µ/22m/220m/10A 0.01µ 220/2.2K/22K/220K/ 2.2M/22M/220MOhm 22n/220n/2.2µ/22µ/ 220µ/2.2m/220mF 22Hz/220Hz/2.2KHz/ 22Hz/220KHz Segnale acustico con resistenza inferiore ai 30 Ohm 0.01Ohm 1nF 0.01Hz ±(1%rdg+3dgt) ±(1.5%rdg+3dgt) ±(0.8%rdg+2dgt) ±(2.5%rdg+3dgt) ±(0.2%rdg+3dgt) Tensione a circuito aperto: circa 2.7 Prova diodi Corrente di prova di circa 1.5mA Tensione a circuito aperto: circa 2.7

Oscilloscopi serie WaveAce

Oscilloscopi serie WaveAce Oscilloscopi serie WaveAce 60 MHz 300 MHz Il collaudo facile, intelligente ed efficiente GLI STRUMENTI E LE FUNZIONI PER TUTTE LE TUE ESIGENZE DI COLLAUDO CARATTERISTICHE PRINCIPALI Banda analogica da

Dettagli

group HIGH CURRENT MULTIPLEX NODE

group HIGH CURRENT MULTIPLEX NODE HIGH CURRENT MULTIPLEX NODE edizione/edition 04-2010 HIGH CURRENT MULTIPLEX NODE DESCRIZIONE GENERALE GENERAL DESCRIPTION L'unità di controllo COBO è una centralina elettronica Multiplex Slave ; la sua

Dettagli

L OSCILLOSCOPIO. L oscilloscopio è il più utile e versatile strumento di misura per il test delle apparecchiature e dei

L OSCILLOSCOPIO. L oscilloscopio è il più utile e versatile strumento di misura per il test delle apparecchiature e dei L OSCILLOSCOPIO L oscilloscopio è il più utile e versatile strumento di misura per il test delle apparecchiature e dei circuiti elettronici. Nel suo uso abituale esso ci consente di vedere le forme d onda

Dettagli

24V DC ±10% 0.5... 1 W. Fluido Fluid. 15 Nl/min

24V DC ±10% 0.5... 1 W. Fluido Fluid. 15 Nl/min elettropiloti 0 mm 0 mm solenoids Elettropilota Solenoid valve 0 mm 00.44.0 ACCESSORI - ACCESSORIES 07.049.0 Connettore per elettropilota 0 mm con cavetto rosso/nero, lunghezza 400 mm - connector for 0

Dettagli

FENICE ARREDI. Via Bertolini 49/51 27029 Vigevano (PV) Relazione tecnica

FENICE ARREDI. Via Bertolini 49/51 27029 Vigevano (PV) Relazione tecnica FENICE ARREDI Via Bertolini 49/51 27029 Vigevano (PV) Prove di vibrazione su sistemi per pavimenti tecnici sopraelevati - Four x Four Relazione tecnica Via Ferrata 1, 27100 Pavia, Italy Tel. +39.0382.516911

Dettagli

TRACER218 MODULO DATALOGGER RS485 MODBUS SPECIFICA PRELIMINARE

TRACER218 MODULO DATALOGGER RS485 MODBUS SPECIFICA PRELIMINARE TRACER218 MODULO DATALOGGER RS485 MODBUS SPECIFICA PRELIMINARE V.00 AGOSTO 2012 CARATTERISTICHE TECNICHE Il modulo TRACER218 485 è un dispositivo con porta di comunicazione RS485 basata su protocollo MODBUS

Dettagli

Manuale d Istruzioni. Extech EX820 Pinza Amperometrica 1000 A RMS con Termometro IR

Manuale d Istruzioni. Extech EX820 Pinza Amperometrica 1000 A RMS con Termometro IR Manuale d Istruzioni Extech EX820 Pinza Amperometrica 1000 A RMS con Termometro IR Introduzione Congratulazioni per aver acquistato la Pinza Amperometrica Extech EX820 da 1000 A RMS. Questo strumento misura

Dettagli

Progetti reali con ARDUINO

Progetti reali con ARDUINO Progetti reali con ARDUINO Introduzione alla scheda Arduino (parte 2ª) ver. Classe 3BN (elettronica) marzo 22 Giorgio Carpignano I.I.S. Primo LEVI - TORINO Il menù per oggi Lettura dei pulsanti Comunicazione

Dettagli

ELCART MANUALE DI ISTRUZIONI MULTIMETRO DIGITALE 9/8220 NI-4100

ELCART MANUALE DI ISTRUZIONI MULTIMETRO DIGITALE 9/8220 NI-4100 ART. 9/8220 PAGINA 1 DI 10 MANUALE DI ISTRUZIONI MULTIMETRO DIGITALE 9/8220 NI-4100 INDICE 1. ISTRUZIONI GENERALI 1.1 Precauzioni di sicurezza 1.1.1 Fasi preliminari 1.1.2 Utilizzo 1.1.3 Simboli 1.1.4

Dettagli

Manuale d'istruzioni. Alimentatore DC Programmabile 200 Watt (40 Volt / 5 Amp) Modello 382280

Manuale d'istruzioni. Alimentatore DC Programmabile 200 Watt (40 Volt / 5 Amp) Modello 382280 Manuale d'istruzioni Alimentatore DC Programmabile 200 Watt (40 Volt / 5 Amp) Modello 382280 382280 Introduzione Congratulazioni per aver acquistato l'alimentatore DC Programmabile 382280 della Extech.

Dettagli

DDS elettronica srl si riserva il diritto di apportare modifiche senza preavviso /we reserves the right to make changes without notice

DDS elettronica srl si riserva il diritto di apportare modifiche senza preavviso /we reserves the right to make changes without notice Maccarone Maccarone Maccarone integra 10 LED POWER TOP alta efficienza, in tecnologia FULL COLOR che permette di raggiungere colori e sfumature ad alta definizione. Ogni singolo led full color di Maccarone

Dettagli

AUDIOSCOPE Mod. 2813-E - Guida all'uso. Rel. 1.0 DESCRIZIONE GENERALE.

AUDIOSCOPE Mod. 2813-E - Guida all'uso. Rel. 1.0 DESCRIZIONE GENERALE. 1 DESCRIZIONE GENERALE. DESCRIZIONE GENERALE. L'analizzatore di spettro Mod. 2813-E consente la visualizzazione, in ampiezza e frequenza, di segnali musicali di frequenza compresa tra 20Hz. e 20KHz. in

Dettagli

Catalogo Trattamento dell Aria - Collezione 2009

Catalogo Trattamento dell Aria - Collezione 2009 Catalogo Trattamento dell Aria - Collezione 2009 SECCOTECH & S 8 SeccoTech & Secco Tecnologia al servizio della deumidificazione Technology at dehumidification's service Potenti ed armoniosi Seccotech

Dettagli

ENERGY-EFFICIENT HOME VENTILATION SYSTEMS

ENERGY-EFFICIENT HOME VENTILATION SYSTEMS SISTEMI DI RECUPERO RESIDENZIALE HOME RECOVERY SYSTEMS RECUPERO DI CALORE AD ALTA EFFICIENZA HIGH EFFICIENCY HEAT RECOVERY VENTILAZIONE A BASSO CONSUMO LOW ENERGY VENTILATION SISTEMI DI RICAMBIO CONTROLLATO

Dettagli

QA-TEMP CONVERTITORE DI TEMPERATURA UNIVERSALE CONVERTITORE DI TEMPERATURA UNIVERSALE. eed quality electronic design

QA-TEMP CONVERTITORE DI TEMPERATURA UNIVERSALE CONVERTITORE DI TEMPERATURA UNIVERSALE. eed quality electronic design Power Fail Rx Tx Dout QEED www.q.it info@q.it CONVERTITORE DI TEMPERATURA UNIVERSALE Isolato a 4 vie - RS485 MODBUS- Datalogger CONVERTITORE DI TEMPERATURA UNIVERSALE Isolato a 4 vie - RS485 MODBUS- Datalogger

Dettagli

Controllare un nastro trasportatore fischertechnik con Arduino

Controllare un nastro trasportatore fischertechnik con Arduino TITOLO ESPERIENZA: Controllare un nastro trasportatore fischertechnik con Arduino PRODOTTI UTILIZZATI: OBIETTIVO: AUTORE: RINGRAZIAMENTI: Interfacciare e controllare un modello di nastro trasportatore

Dettagli

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES Mod VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES Mod VS/AM 65 1 2 VS/AM 65 STANDARD VS/AM 65 CON RACCORDI VS/AM 65

Dettagli

MANUALE UTENTE DEL SOFTWARE DI GESTIONE DEGLI ART. SDVR040A/SDVR080A/SDVR160A

MANUALE UTENTE DEL SOFTWARE DI GESTIONE DEGLI ART. SDVR040A/SDVR080A/SDVR160A MANUALE UTENTE DEL SOFTWARE DI GESTIONE DEGLI ART. SDVR040A/SDVR080A/SDVR160A Leggere attentamente questo manuale prima dell utilizzo e conservarlo per consultazioni future Via Don Arrigoni, 5 24020 Rovetta

Dettagli

BATTERIE ENERGA AL LITIO

BATTERIE ENERGA AL LITIO BATTERIE ENERGA AL LITIO Batterie avviamento ultraleggere - Extra-light starter batteries Le batterie con tecnologia al Litio di ENERGA sono circa 5 volte più leggere delle tradizionali al piombo. Ciò

Dettagli

Serie PicoScope 3000

Serie PicoScope 3000 YE AR Serie PicoScope 3000 I MIGLIORI OSCILLOSCOPI ALIMENTATI TRAMITE USB Potenza e portatilità. Perché accontentarsi? Memoria buffer da 128 M Decodifica seriale Analizzatore di spettro da 200 MHz Generatore

Dettagli

WWW.TINYLOC.COM CUSTOMER SERVICE GPS/ RADIOTRACKING DOG COLLAR. T. (+34) 937 907 971 F. (+34) 937 571 329 sales@tinyloc.com

WWW.TINYLOC.COM CUSTOMER SERVICE GPS/ RADIOTRACKING DOG COLLAR. T. (+34) 937 907 971 F. (+34) 937 571 329 sales@tinyloc.com WWW.TINYLOC.COM CUSTOMER SERVICE T. (+34) 937 907 971 F. (+34) 937 571 329 sales@tinyloc.com GPS/ RADIOTRACKING DOG COLLAR MANUALE DI ISTRUZIONI ACCENSIONE / SPEGNERE DEL TAG HOUND Finder GPS Il TAG HOUND

Dettagli

Metodi e Strumenti per la Caratterizzazione e la Diagnostica di Trasmettitori Digitali RF ing. Gianfranco Miele g.miele@unicas.it

Metodi e Strumenti per la Caratterizzazione e la Diagnostica di Trasmettitori Digitali RF ing. Gianfranco Miele g.miele@unicas.it Corso di laurea magistrale in Ingegneria delle Telecomunicazioni Metodi e Strumenti per la Caratterizzazione e la Diagnostica di Trasmettitori Digitali RF ing. Gianfranco Miele g.miele@unicas.it Trasmettitore

Dettagli

INTERNET e RETI di CALCOLATORI A.A. 2014/2015 Capitolo 4 DHCP Dynamic Host Configuration Protocol Fausto Marcantoni fausto.marcantoni@unicam.

INTERNET e RETI di CALCOLATORI A.A. 2014/2015 Capitolo 4 DHCP Dynamic Host Configuration Protocol Fausto Marcantoni fausto.marcantoni@unicam. Laurea in INFORMATICA INTERNET e RETI di CALCOLATORI A.A. 2014/2015 Capitolo 4 Dynamic Host Configuration Protocol fausto.marcantoni@unicam.it Prima di iniziare... Gli indirizzi IP privati possono essere

Dettagli

M16FA655A - Mark V. Manuale dell Utente - User Manual SIN.NT.002.8. Regolatore di Tensione per Generatori Sincroni Trifase

M16FA655A - Mark V. Manuale dell Utente - User Manual SIN.NT.002.8. Regolatore di Tensione per Generatori Sincroni Trifase M16FA655A - Mark V Manuale dell Utente - User Manual Regolatore di Tensione per Generatori Sincroni Trifase Automatic Voltage Regulator for Three-phase Synchronous Generators (Issued: 09.2010) SIN.NT.002.8

Dettagli

Gi-Gi Art. 859 - User's Guide Istruzioni d'uso

Gi-Gi Art. 859 - User's Guide Istruzioni d'uso doc.4.12-06/03 Gi-Gi Art. 859 - User's Guide Istruzioni d'uso A belaying plate that can be used in many different conditions Una piastrina d'assicurazione che può essere utilizzata in condizioni diverse.

Dettagli

Corso di Informatica Industriale

Corso di Informatica Industriale Corso di Informatica Industriale Prof. Giorgio Buttazzo Dipartimento di Informatica e Sistemistica Università di Pavia E-mail: buttazzo@unipv.it Informazioni varie Telefono: 0382-505.755 Email: Dispense:

Dettagli

Zeroshell come client OpenVPN

Zeroshell come client OpenVPN Zeroshell come client OpenVPN (di un server OpenVpn Linux) Le funzionalità di stabilire connessioni VPN di Zeroshell vede come scenario solito Zeroshell sia come client sia come server e per scelta architetturale,

Dettagli

LA DIFFERENZA È NECTA

LA DIFFERENZA È NECTA LA DIFFERENZA È NECTA SOLUZIONI BREVETTATE PER UNA BEVANDA PERFETTA Gruppo Caffè Z4000 in versione singolo o doppio espresso Tecnologia Sigma per bevande fresh brew Dispositivo Dual Cup per scegliere il

Dettagli

The Future Starts Now. Termometri portatili

The Future Starts Now. Termometri portatili Termometri portatili Temp 70 RTD Professional Datalogger, per sonde Pt100 RTD 0,01 C da -99,99 a +99,99 C 0,1 C da -200,0 a +999,9 C Temp 7 RTD Basic Per sonde Pt100 RTD 0,1 C da -99,9 a +199,9 C 1 C da

Dettagli

Caratteristiche. Camcorder Full HD 3D/2D compatto con sensori CMOS Exmor R da 1/4" e software di editing Vegas. www.pro.sony.

Caratteristiche. Camcorder Full HD 3D/2D compatto con sensori CMOS Exmor R da 1/4 e software di editing Vegas. www.pro.sony. Camcorder Full HD 3D/2D compatto con sensori CMOS Exmor R da 1/4" e software di editing Vegas Pro* Operazioni versatili per registrazioni Full HD 3D e 2D professionali HXR-NX3D1E è un camcorder professionale

Dettagli

Appunti di Misure Elettriche Richiami vari Quantità elettriche corrente ampere elettroni

Appunti di Misure Elettriche Richiami vari Quantità elettriche corrente ampere elettroni Appunti di Misure Elettriche Richiami vari QUANTITÀ ELETTRICHE... 1 Corrente... 1 Tensione... 2 Resistenza... 3 Polarità... 3 Potenza... 4 CORRENTE ALTERNATA... 4 Generalità... 4 Valore efficace... 5 Valore

Dettagli

Istruzioni per l uso. GEOHM 5 Misuratore di Terra 3-349-418-10 1/6.09

Istruzioni per l uso. GEOHM 5 Misuratore di Terra 3-349-418-10 1/6.09 Istruzioni per l uso GEOHM 5 Misuratore di Terra 3-349-418-10 1/6.09 Significato dei simboli sullo strumento Isolamento continuo doppio o rinforzato Segnalazione di un pericolo, (Attenzione, consultare

Dettagli

Termometri portatili. Temp 16 RTD Basic. Temp 10 K Basic Per sonde a termocoppia K. Temp 6 Basic

Termometri portatili. Temp 16 RTD Basic. Temp 10 K Basic Per sonde a termocoppia K. Temp 6 Basic Temp 360 Professional Datalogger, per sonde Pt100 RTD - 0,01 C Temp 300 Professional Datalogger, a doppio canale, per sonde a termocoppia K, T, J, B, R, E, S, N Temp 16 RTD Basic Per sonde Pt100 RTD Temp

Dettagli

Serduino - SERRA CON ARDUINO

Serduino - SERRA CON ARDUINO Serduino - SERRA CON ARDUINO 1 Componenti Facchini Riccardo (responsabile parte hardware) Guglielmetti Andrea (responsabile parte software) Laurenti Lorenzo (progettazione hardware) Rigolli Andrea (reparto

Dettagli

T H O R A F L Y. Sistemi di drenaggio toracico Thoracic drainage systems. Catalogo 2009 - Catalogue 2009 GRUPPO C GROUP C

T H O R A F L Y. Sistemi di drenaggio toracico Thoracic drainage systems. Catalogo 2009 - Catalogue 2009 GRUPPO C GROUP C T H O R A F L Y Sistemi di drenaggio toracico Thoracic drainage systems Catalogo 2009 - Catalogue 2009 GRUPPO C GROUP C SOMMARIO GRUPPO C (SUMMARY C GROUP) 1/C II SISTEMI DI DRENAGGIO TORACICO COMPLETI

Dettagli

Redatto da Product Manager info@e4company.com. Verificato da E4 Team Supporto supporto@e4company.com

Redatto da Product Manager info@e4company.com. Verificato da E4 Team Supporto supporto@e4company.com Redatto da Product Manager info@e4company.com Verificato da E4 Team Supporto supporto@e4company.com 2 SOMMARIO 1 INTRODUZIONE... 4 2 SOLUTION OVERVIEW... 5 3 SOLUTION ARCHITECTURE... 6 MICRO25... 6 MICRO50...

Dettagli

Serie 12 - Interruttore orario 16 A. Caratteristiche SERIE 12 12.01 12.11 12.31

Serie 12 - Interruttore orario 16 A. Caratteristiche SERIE 12 12.01 12.11 12.31 Serie - nterruttore orario 16 A SERE Caratteristiche.01.11.31 nterruttore orario elettromeccanico - Giornaliero * - Settimanale ** Tipo.01-1 contatto in scambio 16 A larghezza 35.8 mm Tipo.11-1 contatto

Dettagli

feeling feeling rf Bedienungsanleitung Operating Manual Mode d emploi Instruzioni per l uso Instrucciones de uso Manual de instruções

feeling feeling rf Bedienungsanleitung Operating Manual Mode d emploi Instruzioni per l uso Instrucciones de uso Manual de instruções feeling feeling rf D GB F E P NL CZ Bedienungsanleitung Operating Manual Mode d emploi nstruzioni per l uso nstrucciones de uso Manual de instruções Bedieningshandleiding Návod k obsluze 2 42 82 122 162

Dettagli

Guida ai Parametri di negoziazione dei mercati regolamentati organizzati e gestiti da Borsa Italiana

Guida ai Parametri di negoziazione dei mercati regolamentati organizzati e gestiti da Borsa Italiana Guida ai Parametri di negoziazione dei mercati regolamentati organizzati e gestiti da Borsa Italiana Versione 04 1/28 INTRODUZIONE La Guida ai Parametri contiene la disciplina relativa ai limiti di variazione

Dettagli

Milliamp Process Clamp Meter

Milliamp Process Clamp Meter 771 Milliamp Process Clamp Meter Foglio di istruzioni Introduzione La pinza amperometrica di processo Fluke 771 ( la pinza ) è uno strumento palmare, alimentato a pile, che serve a misurare valori da 4

Dettagli

SOCCORRITORE IN CORRENTE CONTINUA Rev. 1 Serie SE

SOCCORRITORE IN CORRENTE CONTINUA Rev. 1 Serie SE Le apparecchiature di questa serie, sono frutto di una lunga esperienza maturata nel settore dei gruppi di continuità oltre che in questo specifico. La tecnologia on-line doppia conversione, assicura la

Dettagli

Sistema AirLINE per il pilotaggio ed il Controllo Remoto del Processo WAGO INGRESSI/USCITE remoti e Fieldbus

Sistema AirLINE per il pilotaggio ed il Controllo Remoto del Processo WAGO INGRESSI/USCITE remoti e Fieldbus Sistema AirLINE per il pilotaggio ed il Controllo Remoto del Processo 86-W Sistema integrato compatto di valvole con I/O elettronici Sistemi personalizzati premontati e collaudati per il pilotaggio del

Dettagli

IMPIANTI OFF GRID E SISTEMI DI ACCUMULO

IMPIANTI OFF GRID E SISTEMI DI ACCUMULO IMPIANTI OFF GRID E SISTEMI DI ACCUMULO VIDEO SMA : I SISTEMI OFF GRID LE SOLUZIONI PER LA GESTIONE DELL ENERGIA Sistema per impianti off grid: La soluzione per impianti non connessi alla rete Sistema

Dettagli

BOSCH EDC16/EDC16+/ME9

BOSCH EDC16/EDC16+/ME9 pag. 16 di 49 BOSCH EDC16/EDC16+/ME9 BOSCH EDC16/EDC16+/ME9 Identificare la zona dove sono poste le piazzole dove andremo a saldare il connettore. Le piazzole sono situate in tutte le centraline Bosch

Dettagli

Controllo industriale SE-609

Controllo industriale SE-609 Controllo industriale SE-609 Controllo e visualizzazione uniti come soluzione per l automazione con comandi mediante touch Controlli industriali all avanguardia per impianti per il trattamento termico

Dettagli

Manuale per l utilizzo di Orderman Sol e Sol+

Manuale per l utilizzo di Orderman Sol e Sol+ Manuale per l utilizzo di Orderman Sol e Sol+ 2010 by Orderman GmbH Bachstraße 59, 5023 Salisburgo Austria www.orderman.it Salvo errori e refusi. Non è consentita la copia - anche di estratti - senza l'autorizzazione

Dettagli

Stazione Meteorologica PCE-FWS 20

Stazione Meteorologica PCE-FWS 20 www.pce-italia.it Istruzioni d uso Stazione Meteorologica PCE-FWS 20 1 Istruzioni d uso www.pce-italia.it Indice dei contenuti Titolo 1. Visione generale... 3 2. Contenuto della spedizione... 3 3. Informazione

Dettagli

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. Manuale utente

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. Manuale utente Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1 Manuale utente Indice Avvisi di Sicurezza... 2 1 Introduzione... 3 2 Caratteristiche Generali... 3 3 Ricevimento e Collocazione... 4

Dettagli

Strumenti Elettronici Analogici/Numerici

Strumenti Elettronici Analogici/Numerici Facoltà di Ingegneria Università degli Studi di Firenze Dipartimento di Elettronica e Telecomunicazioni Strumenti Elettronici Analogici/Numerici Ing. Andrea Zanobini Dipartimento di Elettronica e Telecomunicazioni

Dettagli

ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE

ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE Mediatrix 2102 ATA Guida all installazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DEL MEDIATRIX 2102...3 COLLEGAMENTO

Dettagli

REGOLAZIONI PARAMETRI DAL MENU DI SERVIZIO

REGOLAZIONI PARAMETRI DAL MENU DI SERVIZIO REGOLAZIONI PARAMETRI DAL MENU DI SERVIZIO ATTENZIONE : le operazioni di regolazione dei parametri di funzionamento richiedono molta attenzione. L'autore di queste note non deve essere ritenuto responsabile

Dettagli

Catalogo Trattamento dell Aria - Collezione 2009

Catalogo Trattamento dell Aria - Collezione 2009 Catalogo Trattamento dell Aria - Collezione 2009 SECCOASCIUTT 16 SeccoAsciutto EL & SeccoAsciutto Thermo Piccolo e potente, deumidifica e asciuga Small and powerful, dehumidifies and dries Deumidificare

Dettagli

Data Alignment and (Geo)Referencing (sometimes Registration process)

Data Alignment and (Geo)Referencing (sometimes Registration process) Data Alignment and (Geo)Referencing (sometimes Registration process) All data aquired from a scan position are refered to an intrinsic reference system (even if more than one scan has been performed) Data

Dettagli

Bus di sistema. Bus di sistema

Bus di sistema. Bus di sistema Bus di sistema Permette la comunicazione (scambio di dati) tra i diversi dispositivi che costituiscono il calcolatore E costituito da un insieme di fili metallici che danno luogo ad un collegamento aperto

Dettagli

Il risparmio energetico nell illuminazione. Automatic System

Il risparmio energetico nell illuminazione. Automatic System Il risparmio energetico nell illuminazione con lampade HID Automatic System DATI RELATIVI AL RISPARMIO ENERGETICO E TABELLE DI CALCOLO PER OTTENERE BENEFIT RISPARMIO LORDO DI ENERGIA PRIMARIA HYBRID CONTROL

Dettagli

Lezione 12: La visione robotica

Lezione 12: La visione robotica Robotica Robot Industriali e di Servizio Lezione 12: La visione robotica L'acquisizione dell'immagine L acquisizione dell immagine Sensori a tubo elettronico (Image-Orthicon, Plumbicon, Vidicon, ecc.)

Dettagli

Compressori serie P Dispositivi elettrici (PA-05-02-I)

Compressori serie P Dispositivi elettrici (PA-05-02-I) Compressori serie P Dispositivi elettrici (PA-05-02-I) 5. MOTORE ELETTRICO 2 Generalità 2 CONFIGURAZIONE PART-WINDING 2 CONFIGURAZIONE STELLA-TRIANGOLO 3 Isolamento del motore elettrico 5 Dispositivi di

Dettagli

Ingresso mv c.c. Da 0 a 200 mv 0,01 mv. Uscita di 24 V c.c. Ingresso V c.c. Da 0 a 25 V 0,001 V. Ingresso ma c.c. Da 0 a 24 ma 0,001 ma

Ingresso mv c.c. Da 0 a 200 mv 0,01 mv. Uscita di 24 V c.c. Ingresso V c.c. Da 0 a 25 V 0,001 V. Ingresso ma c.c. Da 0 a 24 ma 0,001 ma 715 Volt/mA Calibrator Istruzioni Introduzione Il calibratore Fluke 715 Volt/mA (Volt/mA Calibrator) è uno strumento di generazione e misura utilizzato per la prova di anelli di corrente da 0 a 24 ma e

Dettagli

User Manual ULTRA-DI DI20. Professional Active 2-Channel DI-Box/Splitter

User Manual ULTRA-DI DI20. Professional Active 2-Channel DI-Box/Splitter User Manual ULTRA-DI DI20 Professional Active 2-Channel DI-Box/Splitter 2 ULTRA-DI DI20 Indice Grazie...2 1. Benvenuti alla BEHRINGER!...6 2. Elementi di Comando...6 3. Possibilità Di Connessione...8 3.1

Dettagli

User guide Conference phone Konftel 100

User guide Conference phone Konftel 100 User guide Conference phone Konftel 100 Dansk I Deutsch I English I Español I Français I Norsk Suomi I Svenska Conference phones for every situation Sommario Descrizione Connessioni, accessoires, ricambi

Dettagli

1 RELÈ ALLO STATO SOLIDO 1 SOLID-STATE RELAYS

1 RELÈ ALLO STATO SOLIDO 1 SOLID-STATE RELAYS 1 RELÈ ALLO STATO SOLIDO 1 SOLID-STATE RELAYS La produzione base dei relè allo stato solido EL.CO. si divide in tre gruppi principali: 1. Relè a commutazione zero (zero crossing) I relè a commutazione

Dettagli

PicoScope 9200A. www.picotech.com. Oscilloscopi a campionamento completi per PC. Oscilloscopi a campionamento per PC Windows

PicoScope 9200A. www.picotech.com. Oscilloscopi a campionamento completi per PC. Oscilloscopi a campionamento per PC Windows PicoScope 9200A Oscilloscopi a campionamento per PC Windows Oscilloscopi a campionamento completi per PC Caratterizzazione del segnale Verifica di pre-conformità TDR e TDT elettriche Verifica pass/fail

Dettagli

Peltor DECT-Com II. The Sound Solution. User s manual for DECT-Com II

Peltor DECT-Com II. The Sound Solution. User s manual for DECT-Com II Peltor DECT-Com II The Sound Solution User s manual for DECT-Com II DECT 1.8 GHz GUIDA RAPIDA Peltor DECT-Com II Pulsante Funzione [M] [+] [ ] [M] e [+] [M] e [ ] Accende/spegne l unità DECT-Com II Seleziona

Dettagli

Ministero della Salute Direzione Generale della Ricerca Scientifica e Tecnologica Bando Giovani Ricercatori - 2007 FULL PROJECT FORM

Ministero della Salute Direzione Generale della Ricerca Scientifica e Tecnologica Bando Giovani Ricercatori - 2007 FULL PROJECT FORM ALLEGATO 2 FULL PROJECT FORM FORM 1 FORM 1 General information about the project PROJECT SCIENTIFIC COORDINATOR TITLE OF THE PROJECT (max 90 characters) TOTAL BUDGET OF THE PROJECT FUNDING REQUIRED TO

Dettagli

SOHO IP-PBX - ETERNITY GE IP-PBX per mobilità senza confini e connettività universale

SOHO IP-PBX - ETERNITY GE IP-PBX per mobilità senza confini e connettività universale SOHO IP-PBX - ETERNITY GE 1 ETERNITY GE è un sistema di comunicazione avanzato e flessibile, che offre servizi e funzionalità utili alle grandi imprese, in linea con le loro richieste. La sua affidabile

Dettagli

Virtualizzazione con Microsoft Tecnologie e Licensing

Virtualizzazione con Microsoft Tecnologie e Licensing Microsoft Virtualizzazione con Microsoft Tecnologie e Licensing Profile Redirezione dei documenti Offline files Server Presentation Management Desktop Windows Vista Enterprise Centralized Desktop Application

Dettagli

e-spare Parts User Manual Peg Perego Service Site Peg Perego [Dicembre 2011]

e-spare Parts User Manual Peg Perego Service Site Peg Perego [Dicembre 2011] Peg Perego Service Site Peg Perego [Dicembre 2011] 2 Esegui il login: ecco la nuova Home page per il portale servizi. Log in: welcome to the new Peg Perego Service site. Scegli il servizio selezionando

Dettagli

SOHO IP-PBX - ETERNITY NE La nuova generazione di IP-PBX per le piccole imprese

SOHO IP-PBX - ETERNITY NE La nuova generazione di IP-PBX per le piccole imprese SOHO IP-PBX - NE 1 NE Oggi, per competere, anche le piccole imprese devono dotarsi di sistemi di telecomunicazione evoluti, che riducano i costi telefonici, accrescano produttività e qualità del servizio.

Dettagli

2capitolo. Alimentazione elettrica

2capitolo. Alimentazione elettrica 2capitolo Alimentazione elettrica Regole fondamentali, norme e condotte da seguire per gestire l'interfaccia tra la distribuzione elettrica e la macchina. Presentazione delle funzioni di alimentazione,

Dettagli

Dell Smart-UPS 1500 3000 VA

Dell Smart-UPS 1500 3000 VA Dell Smart-UPS 100 000 VA 0 V Protezione interattiva avanzata dell'alimentazione per server e apparecchiature di rete Affidabile. Razionale. Efficiente. Gestibile. Dell Smart-UPS, è l'ups progettato da

Dettagli

Sviluppo di procedure di misura complesse basate su tone bursts

Sviluppo di procedure di misura complesse basate su tone bursts Sviluppo di procedure di misura complesse basate su tone bursts M. Bigi, M. Jacchia, D. Ponteggia Metodi di misura e di elaborazione del segnale nella riproduzione elettroacustica del suono Rimini, 38

Dettagli

Web conferencing software. Massimiliano Greco - Ivan Cerato - Mario Salvetti

Web conferencing software. Massimiliano Greco - Ivan Cerato - Mario Salvetti 1 Web conferencing software Massimiliano Greco - Ivan Cerato - Mario Salvetti Arpa Piemonte 2 Che cosa è Big Blue Button? Free, open source, web conferencing software Semplice ed immediato ( Just push

Dettagli

PROGETTO E SIMULAZIONI DEL SISTEMA PROPRIETARIO DI LINEE DI TRASMISSIONE. (DDDL= Dual Drive Dual Line) Implementato per il modello CANTICO CX8.

PROGETTO E SIMULAZIONI DEL SISTEMA PROPRIETARIO DI LINEE DI TRASMISSIONE. (DDDL= Dual Drive Dual Line) Implementato per il modello CANTICO CX8. 1 PROGETTO E SIMULAZIONI DEL SISTEMA PROPRIETARIO DI LINEE DI TRASMISSIONE D3L (DDDL= Dual Drive Dual Line) Implementato per il modello CANTICO CX8. CX via ottavio rinuccini, 3 milano info@labirintiacustici.it

Dettagli

Technical Support Bulletin No. 15 Problemi Strumentazione

Technical Support Bulletin No. 15 Problemi Strumentazione Technical Support Bulletin No. 15 Problemi Strumentazione Sommario! Introduzione! Risoluzione dei problemi di lettura/visualizzazione! Risoluzione dei problemi sugli ingressi digitali! Risoluzione di problemi

Dettagli

Soluzioni multifunzionali, ideali per gestire ogni flusso di lavoro

Soluzioni multifunzionali, ideali per gestire ogni flusso di lavoro Soluzioni multifunzionali, ideali per gestire ogni flusso di lavoro Sistemi digitali per l ufficio sempre più efficienti e facili da usare Ottenere massima efficienza ed elevata professionalità, pur mantenendo

Dettagli

Il manuale dell utente può essere scaricato dal sito gopro.com/support GUIDA DI RIFERIMENTO RAPIDO

Il manuale dell utente può essere scaricato dal sito gopro.com/support GUIDA DI RIFERIMENTO RAPIDO Il manuale dell utente può essere scaricato dal sito gopro.com/support GUIDA DI RIFERIMENTO RAPIDO / Benvenuto Quando si utilizza la videocamera GoPro nell ambito delle normali attività quotidiane, prestare

Dettagli

Altivar Process Variatori di velocità ATV630, ATV650

Altivar Process Variatori di velocità ATV630, ATV650 Altivar Process EAV64310 05/2014 Altivar Process Variatori di velocità ATV630, ATV650 Manuale di installazione 05/2014 EAV64310.01 www.schneider-electric.com Questa documentazione contiene la descrizione

Dettagli

Batterie per recinti. Batteria alcalina a secco 9 V. Batteria a secco 9 V zinco-carbonio

Batterie per recinti. Batteria alcalina a secco 9 V. Batteria a secco 9 V zinco-carbonio Batterie per recinti Batteria alcalina a secco 9 V Le batterie alcaline AKO 9 V mantengo un alto voltaggio costante per tutta la loro durata. Questo permette al recinto di mantenere un andamento costante

Dettagli

Brushless. Brushless

Brushless. Brushless Motori Motori in in corrente corrente continua continua Brushless Brushless 69 Guida alla scelta di motori a corrente continua Brushless Riduttore 90 Riddutore Coppia massima (Nm)! 0,6,7 30 W 5,5 max.

Dettagli

Serie RTC. Prospetto del catalogo

Serie RTC. Prospetto del catalogo Serie RTC Prospetto del catalogo Bosch Rexroth AG Pneumatics Serie RTC Cilindro senza stelo, Serie RTC-BV Ø 16-80 mm; a doppio effetto; con pistone magnetico; guida integrata; Basic Version; Ammortizzamento:

Dettagli

CATENE E COMPONENTI DI GRADO 8-10-INOX, BRACHE DI POLIESTERE E ANCORAGGI, BRACHE DI FUNE

CATENE E COMPONENTI DI GRADO 8-10-INOX, BRACHE DI POLIESTERE E ANCORAGGI, BRACHE DI FUNE CATENE E COMPONENTI DI GRADO 8-10-INOX, BRACHE DI POLIESTERE E ANCORAGGI, BRACHE DI FUNE L esperienza e la passione per l ingegneria sono determinanti per la definizione della nostra politica di prodotto,

Dettagli

Doc: MHIT101A0309.doc 21/01/2010 p. 1 / 22

Doc: MHIT101A0309.doc 21/01/2010 p. 1 / 22 I 300 I GB 0110 COMMUTATORE AUTOMATICO DI RETE ATL10 AUTOMATIC TRANSFER SWITCH CONTROLLER ATL10 ATTENZIONE!! Leggere attentamente il manuale prima dell utilizzo e l installazione. Questi apparecchi devono

Dettagli

Frigoriferi portatili 12/24-115/230V 12/24-115/230V portable refrigerators

Frigoriferi portatili 12/24-115/230V 12/24-115/230V portable refrigerators Travel Box Frigoriferi portatili 12/24-115/230V 12/24-115/230V portable refrigerators Studio PrimoPiano - Ad. giuseppina.dolci@alice.it - Ph. Leon - Stampa CDPress - 10/2010 Travel Box / Travel Box Modello

Dettagli

RefWorks Guida all utente Versione 4.0

RefWorks Guida all utente Versione 4.0 Accesso a RefWorks per utenti registrati RefWorks Guida all utente Versione 4.0 Dalla pagina web www.refworks.com/refworks Inserire il proprio username (indirizzo e-mail) e password NB: Agli utenti remoti

Dettagli

Sopra ogni aspettativa

Sopra ogni aspettativa Sopra ogni aspettativa Pipette elettroniche Eppendorf Xplorer e Eppendorf Xplorer plus »Un modo intuitivo di lavorare.«chi dà il massimo ogni giorno, merita anche il massimo in termini di strumenti ed

Dettagli

Document Name: RIF. MonoMotronic MA 3.0 512 15/54 30 15 A 10 A 10 M 1 234

Document Name: RIF. MonoMotronic MA 3.0 512 15/54 30 15 A 10 A 10 M 1 234 MonoMotronic MA.0 6 7 8 9 / 0 8 7 6 0 9 A B A L K 7 8 6 9 0 8 0 A 0 0 C E D 6 7 7 M - 6 0 9 7-9 LEGENDA Document Name: MonoMotronic MA.0 ) Centralina ( nel vano motore ) ) Sensore di giri e P.M.S. ) Attuatore

Dettagli

Principali prove meccaniche su materiali polimerici

Principali prove meccaniche su materiali polimerici modulo: Proprietà viscoelastiche e proprietà meccaniche dei polimeri Principali prove meccaniche su materiali polimerici R. Pantani Scheda tecnica di un materiale polimerico Standard per prove meccaniche

Dettagli

GENERALITA SUI CONVERTITORI DAC E ADC CONVERTITORI DIGITALE-ANALOGICO DAC

GENERALITA SUI CONVERTITORI DAC E ADC CONVERTITORI DIGITALE-ANALOGICO DAC I.T.I. Modesto PANETTI A R I ia Re David, 86-8-54.54. - 75 ARI Fax 8-54.64.3 Internet http://www.itispanetti.it email : ATF5C@istruzione.it Tesina sviluppata dall alunno Antonio Gonnella della classe 5

Dettagli

Generatori di segnale. Generatore sinusoidale BF. Generatori di funzione. Generatori sinusoidali a RF. Generatori a battimenti. Oscillatori a quarzo

Generatori di segnale. Generatore sinusoidale BF. Generatori di funzione. Generatori sinusoidali a RF. Generatori a battimenti. Oscillatori a quarzo Generatori di segnale Generatore sinusoidale BF Generatori di funzione Generatori sinusoidali a RF Generatori a battimenti Oscillatori a quarzo Generatori per sintesi indiretta 2 2006 Politecnico di Torino

Dettagli

SIRe Competent Fan Heater Electric. SIReFCX. With quick guide. For wiring diagram, please see last pages SE... 2 ES... 70 ... 155 ...

SIRe Competent Fan Heater Electric. SIReFCX. With quick guide. For wiring diagram, please see last pages SE... 2 ES... 70 ... 155 ... Original instructions SIRe Competent Fan Heater Electric With quick guide SIReFCX SE... 2 GB... 19 DE... 36 FR... 53 ES... 70 IT... 87 NL... 104 NO... 121 PL... 138 RU... 155 For wiring diagram, please

Dettagli

Introduzione agli oscilloscopi

Introduzione agli oscilloscopi o s c i l l o s c o p i Indice Introduzione...3 Integrità del segnale Significato dell integrità del segnale..................................4 Perché l integrità del segnale è un problema?...........................4

Dettagli

UPS Communicator. UPS Communicator - Manuale Italiano Release 1.16 1

UPS Communicator. UPS Communicator - Manuale Italiano Release 1.16 1 UPS Communicator 1 Licenza d uso L'uso del SOFTWARE prodotto da Legrand (il PRODUTTORE) è gratuito. Procedendo di spontanea volontà all'installazione l UTENTE (persona fisica o giuridica) accetta i rischi

Dettagli

Altre novità della nostra ampia gamma di strumenti!

Altre novità della nostra ampia gamma di strumenti! L innovazione ad un prezzo interessante Altre novità della nostra ampia gamma di strumenti! Exacta+Optech Labcenter SpA Via Bosco n.21 41030 San Prospero (MO) Italia Tel: 059-808101 Fax: 059-908556 Mail:

Dettagli

Termometro Infrarossi ad Alte Temperature con Puntatore Laser

Termometro Infrarossi ad Alte Temperature con Puntatore Laser Manuale d Istruzioni Termometro Infrarossi ad Alte Temperature con Puntatore Laser MODELLO 42545 Introduzione Congratulazioni per aver acquistato il Termometro IR Modello 42545. Il 42545 può effettuare

Dettagli

Arduino: Programmazione

Arduino: Programmazione Programmazione formalmente ispirata al linguaggio C da cui deriva. I programmi in ARDUINO sono chiamati Sketch. Un programma è una serie di istruzioni che vengono lette dall alto verso il basso e convertite

Dettagli

AC Anywhere. Inverter. Manuale utente. F5C400u140W, F5C400u300W F5C400eb140W e F5C400eb300W

AC Anywhere. Inverter. Manuale utente. F5C400u140W, F5C400u300W F5C400eb140W e F5C400eb300W AC Anywhere Inverter (prodotto di classe II) Manuale utente F5C400u140W, F5C400u300W F5C400eb140W e F5C400eb300W Leggere attentamente le istruzioni riguardanti l installazione e l utilizzo prima di utilizzare

Dettagli

Manuale d Uso. Ref: 04061

Manuale d Uso. Ref: 04061 Manuale d Uso Ref: 04061 1 Grazie per aver acquistato il lettore digitale ENERGY SISTEM INNGENIO 2000. Questo manuale fornisce istruzioni operative dettagliate e spiegazioni delle funzioni per godere al

Dettagli

2013 SECOND GENERATION CO 2 COMPRESSOR

2013 SECOND GENERATION CO 2 COMPRESSOR CD 2013 SECOND GENERATION CO 2 COMPRESSOR Introduzione / Introduction 3 Gamma completa / Complete range 4 Pesi e rubinetti / Weight and valves 4 Caratteristiche tecniche / Technical data 4 Max corrente

Dettagli

Inverter solari ABB L offerta più completa del settore

Inverter solari ABB L offerta più completa del settore Inverter solari ABB L offerta più completa del settore Inverter di stringa 8-35 PV + Storage 38-43 Inverter centralizzati 46-55 Stazioni chiavi in mano 58-71 Monitoraggio e comunicazione 74-113 Service

Dettagli

AMPLIFICATORE LINEARE 1KW A STATO SOLIDO COMPLETAMENTE AUTOMATICO MANUALE D USO

AMPLIFICATORE LINEARE 1KW A STATO SOLIDO COMPLETAMENTE AUTOMATICO MANUALE D USO AMPLIFICATORE LINEARE 1KW A STATO SOLIDO COMPLETAMENTE AUTOMATICO MANUALE D USO SECONDA SERIE CERTIFICATO CE/FCC Pag. 2 di 2 Indice IMPORTANTE...5 PRECAUZIONI...5 DISIMBALLAGGIO...7 1. DESCRIZIONE DEI

Dettagli