RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare

Dimensione: px
Iniziare la visualizzazioe della pagina:

Download "RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare"

Transcript

1 RPS Endurance System Solutions for solar energy Soluzioni per l energia solare 2015/2016

2 Power, control and green solutions

3 3 RPS Endurance A compact powerhouse. s cutting-edge RPS Endurance inverter family grows bigger: With an extended unit power rating of up to 563 kwac and the introduction of a new feature to operate two units in parallel on a single medium-voltage transformer winding, the performance and ease of handling of RPS Endurance inverters is now available also for large PV stations of 2 MW and above. Designed for maximum productivity even in the toughest conditions and constructed with a record footprint, the RPS Endurance is a robust, compact powerhouse. The intelligent two-stage encapsulation design maximizes uptime through a full IP54 ambient protection degree of active components, while the wide operating temperature range and a best-in-class 15 % overload capacity at low-temperature conditions guarantee excellent productivity. Thanks to advanced air cooling technology, the inverter design ensures outstanding reliability and serviceability. With numerous selfprotection functions and grid management options, the RPS Endurance is built to satisfy your power control requirements in the fast-developing global PV market. Main features kwac unit power rating at 50 C ambient temperature Possibility to operate two units in parallel on common ac output without need for galvanic isolation Excellent 15 % overload capacity at reduced ambient temperature Indoor-rated with full IP54 ambient protection of active components including power electronics, controls/sensors and switchgear High reliability and easy serviceability through robust air cooling design Very compact dimensions allow for easy transportation and installation Extensive grid management capabilities including BDEW certification L avanguardistica famiglia di inverter RPS Endurance di è cresciuta: con una classe di potenza ampliata fino a 563 kwac e l introduzione di una nuova funzione per utilizzare due unità in parallelo su un singolo avvolgimento di trasformatore di media tensione, le prestazioni e la facilità di gestione degli inverter Endurance RPS sono ora pienamente disponibili anche per grandi stazioni fotovoltaiche da 2 MW e oltre. Progettati per la massima produttività anche nelle condizioni più difficili e costruiti con un ingombro record, gli RPS Endurance sono concentrati di energia robusti e compatti. L intelligente design incapsulato a due stadi massimizza la disponibilità operativa grazie al grado di protezione ambientale IP54 dei componenti attivi, mentre l ampio intervallo di temperature d esercizio e una capacità di sovraccarico best-in-class del 15% alle basse temperature assicurano una produttività eccellente. Grazie all avanzata tecnologia di raffreddamento dell aria, il design degli inverter garantisce un affidabilità e una facilità di manutenzione eccezionali. Con numerose funzioni di auto-protezione e opzioni di gestione della rete, gli inverter RPS Endurance sono costruiti per soddisfare i vostri requisiti di controllo della potenza nel mercato globale in rapido sviluppo del fotovoltaico. Caratteristiche principali Classe di potenza di kwac ad una temperatura ambiente di 50 C Possibilità di gestire due unità in parallelo su un uscita CA comune senza necessità di isolamento galvanico Eccellente capacità di sovraccarico del 15% a basse temperature ambiente Idoneità per installazione indoor con classe di protezione ambientale IP54 dei componenti attivi quali elettronica di potenza, controlli/sensori e interruttori Elevata affidabilità e facilità di manutenzione grazie al robusto design del sistema di raffreddamento dell aria Dimensioni estremamente compatte per la facilità di trasporto e installazione Estese funzionalità di gestione della rete, inclusa la certificazione BDEW

4 Integration of RPS Endurance inverters with the PV plant. Integrazione degli inverter RPS Endurance nell impianto fotovoltaico. Courtesy of SunEdison Per gentile concessione di SunEdison

5 5 Every kilowatt-hour counts: extra-wide operating range for maximum energy yield. Ogni chilowattora conta: vastissimo intervallo operativo per la massima resa energetica. SunEdison Solar Park in Bulgaria: 60 MW - Inverters. SunEdison Impianto a terra in Bulgaria: 60 MW - Inverter. While RPS Endurance inverters feature a stateof-art power efficiency of up to 98.6 %, they are also designed for an extraordinary wide power operating range that can make the difference in maximizing power generation: Up to 15% permanent overload capability at reduced ambient temperatures RPS Endurance inverters reliably operate at their rated power at ambient temperatures up to 50 C. If lower ambient temperatures allow it, the inverter power output is automatically increased by up to 15 %. This means that an RPS ND 0500 unit wit a rated power of 500 kw will actually generate an impressive 575 kw at 25 C ambient, and even so at 35 C ambient if the MPP voltage is maintained below 700 V as shown in the figure below. Full power even down to low input voltages Many inverters do not supply rated power over their entire specified MPP voltage range. RPS Endurance inverters are designed to supply rated power even at minimum input voltages, which can be very helpful to increase production in PV plants with high dc-to-ac power ratios. Oltre ad assicurare un efficienza energetica allo stato dell arte fino al 98,6%, gli inverter RPS Endurance sono progettati per lavorare entro un intervallo operativo straordinariamente ampio che può fare la differenza nella massimizzazione della generazione di potenza: Fino al 15% di capacità di sovraccarico permanente a temperature ambiente ridotte Gli inverter RPS Endurance funzionano in modo affidabile alla potenza nominale a temperature ambiente fino a 50 C. Se temperature ambiente più basse lo consentono, la potenza in uscita dell inverter è automaticamente aumentata fino al 15%. Ciò significa che un unità RPS ND 0500 con una potenza nominale di 500 kw arriverà a generare addirittura 575 kw a 25 C di temperatura ambiente, e anche a 35 C se la tensione MPP è mantenuta sotto 700 V come mostrato in figura. Massima potenza fino a basse tensioni di ingresso Molti inverter non forniscono la potenza nominale nel loro intero intervallo di tensione MPP specificato. Gli inverter RPS Endurance sono progettati per fornire la potenza nominale anche a tensioni di ingresso minime (550 V) e ciò può essere molto utile per aumentare la produzione negli impianti FV con elevati rapporti di potenza CA-CC. RPS Endurance power-temperature operating range. Intervallo operativo potenza-temperatura degli RPS Endurance. 115% 100% 95% Extended low-temperature power range Intervallo operativo esteso alle basse temperature Extended high-temperature power range Intervallo operativo esteso alle alte temperature -20 C 0 C 35 C 50 C 55 C T ambient T ambiente at V mpp below 700 V a V mpp inferiore a 700 V

6 6 Comprehensive functional safety features. Funzioni di sicurezza funzionale complete. Operating and commissioning conditions for photovoltaic inverters can be demanding. In addition to its robust design, the RPS Endurance provides a comprehensive set of functional safety features. Le condizioni operative e di messa in servizio degli inverter fotovoltaici possono essere complesse. In aggiunta al loro robusto design, gli inverter RPS Endurance offrono una serie completa di funzioni di sicurezza funzionale. AC and DC-side polarity reversal and mis-wiring protection There are times when people simply make mistakes. With the built in protection functions, personnel and equipment are protected in cases of mis-wiring at the ac and dc power terminals and clear indications help to quickly identify and correct errors. Auxiliary power interruption immunity If for whatever reason the auxiliary power supply is interrupted, the built in protection features of the inverter will safely protect itself and your investment. With the optional integrated UPS, inverters will operate through all temporary supply-side disturbances smoothly without loss of production. Under- and overvoltage ride-through capability Unstable grids plague the world we live in. This is why the RPS Endurance with its advanced grid management system will automatically determine the right action in case of grid events and keep production up and running whenever possible. Active thermal cycling mitigation A dedicated control algorithm keeps operating temperatures of key components inside the inverter in a narrow range, mitigating thermal cycles that are a main source of fatigue and thereby maximizing the service life of the equipment. Full circuit breaker protection No compromise: quality circuit breakers safely isolate the inverter automatically or through remote command in the presence of rare abnormal conditions, protecting the equipment until maintenance intervention. Protezione dall inversione di polarità lato CA e CC e dagli errori di cablaggio Ci sono momenti in cui le persone semplicemente commettono errori. Con le funzioni di protezione incorporate, il personale e le apparecchiature sono protetti in caso di errori di cablaggio sui morsetti di potenza CA e CC, mentre indicazioni chiare aiutano a identificare rapidamente e a correggere gli errori. Immunità dall interruzione della potenza ausiliaria Se per qualsiasi motivo l alimentazione ausiliaria viene interrotta, le funzioni di protezione incorporate proteggeranno l inverter e il vostro investimento. Con l UPS integrato optional, gli inverter funzioneranno regolarmente senza perdite di produzione durante tutti i disturbi di alimentazione temporanei. Capacità di ovviare a sottotensione e sovratensione Il mondo in cui viviamo è afflitto da reti instabili. Questo è il motivo per cui gli RPS Endurance con il loro sistema avanzato di gestione della rete determineranno automaticamente l azione corretta nel caso di guasti di rete, mantenendo attiva la produzione quando possibile. Mitigazione dei cicli termici attivi Un algoritmo di controllo dedicato mantiene entro un range ristretto le temperature d esercizio dei componenti chiave all interno dell inverter, mitigando i cicli termici che sono la principale fonte di usura e massimizzando così la vita utile delle apparecchiature. Protezione completa con gli interruttori automatici Nessun compromesso: interruttori automatici di qualità isolano l inverter, automaticamente o tramite comando remoto, in presenza di rare condizioni anomale, proteggendo le apparecchiature in tutta sicurezza fino all intervento di manutenzione.

7 7 Innovative ambient protection system. Innovativo sistema di protezione ambientale. A unique feature for indoor-rated PV inverters, the innovative two-zone ambient protection system distinguishes the RPS Endurance from other solutions, as it effectively isolates the inverter s critical components from dust and pollution through a full IP54 protection regime and an intelligent airflow design. This makes the RPS Endurance a preferred choice wherever harsh conditions for plant installation and operation are present, such as in the sunbelt regions of the world, where has a long-standing track record with extensive operational experience. Caratteristica unica degli inverter FV idonei per installazione indoor, l innovativo sistema di protezione ambientale a due zone contraddistingue gli RPS Endurance dalle altre soluzioni, in quanto isola efficacemente i componenti critici degli inverter da polvere e inquinamento grazie a un completo regime di protezione IP54 e a un intelligente design del flusso d aria. Questo rende gli RPS Endurance la scelta perfetta ovunque siano presenti difficili condizioni di installazione e funzionamento dell impianto, come ad esempio nelle regioni della cosiddetta fascia solare del mondo, dove vanta una lunga e comprovata esperienza operativa. Air outlet Fuoriuscita aria Zone IP54 Key power components Componenti di potenza chiave Cold air intake Aspirazione aria fredda

8

9 9 Industry leading compact footprint. Dimensioni compatte ai vertici del settore. The innovative cooling concept allows more components to be placed in a smaller area. This increases the power density and decreases the required installation space and footprint, resulting in cost savings regarding packaging, shipping, transportation, and installation. The cooling concept is coupled with an intelligent cabinet layout that allows easy access to all critical components from a single access panel making maintenance a breeze. L innovativo concetto di raffreddamento permette di collocare un maggior numero di componenti in un area più contenuta. Ciò aumenta la densità di potenza e riduce lo spazio e l ingombro richiesti per l installazione, con conseguenti risparmi in termini di imballaggio, spedizione, trasporto e installazione. Il concetto di raffreddamento è abbinato ad un intelligente layout degli armadi per permettere il facile accesso a tutti i componenti critici da un unico pannello che rende la manutenzione un gioco da ragazzi. 800 mm mm mm RPS Endurance 500 kw 2200 mm 2000 mm Competition 500 kw 1200 mm 1200 mm 2000 mm

10 10 Great teamwork Master-Slave parallel configuration. Grande lavoro di squadra Configurazione parallela Master-Slave. Benefitting from its profound expertise in inverter technology, is able to offer RPS Endurance inverters with a synchronisation function to operate two units on a common ac output in a Master-Slave mode. The selective activation of each of the two units, both connected to a common dc combiner with flexible input and grounding configuration, increases the part-load efficiency of the system and helps to further optimize the operation life of the equipment. This way, a typical 2 to 2.25 MWac inverter station solution can be conveniently realized with 2 x 2 Endurance systems and a conventional three-winding transformer. Avvalendosi della sua vasta esperienza nella tecnologia degli inverter, è in grado di offrire inverter RPS Endurance con funzione di sincronizzazione per azionare due unità su un uscita CA comune in modalità master-slave. L attivazione selettiva di ciascuna delle due unità, entrambe collegate ad un combinatore CC comune con una flessibile configurazione della messa a terra e degli ingressi, aumenta l efficienza a carico parziale del sistema e contribuisce all ulteriore ottimizzazione della vita operativa delle apparecchiature. In questo modo, una tipica stazione inverter da 2-2,25 MWac può essere opportunamente realizzata con 2 x 2 sistemi Endurance e un trasformatore a tre avvolgimenti convenzionale. Typical System Configuration for MWac Inverter Station Solution with 2 x 2 RPS Endurance. Tipica configurazione di sistema per stazioni inverter da 2 2,25 MWac con 2 x 2 RPS Endurance.

11 11 Straight & Simple Stand-Alone configuration. Semplice e diretta la configurazione Stand-Alone. For smaller PV stations, RPS Endurance inverters comprise all necessary components and functions for a direct connection of units to individual medium-voltage transformer winding ( standalone configuration ). On the dc side, each inverter can be connected to an external dc combiner with a configurable number of inputs and a flexible grounding configuration. Alternatively, a simple and compact Fusebox solution is available for grounded PV generators with a maximum number of 6 dc inputs per pole to each Endurance unit. In the stand-alone configuration, two units may be connected to a conventional three-winding transformer to form a 1t to MWac inverter station. Per stazioni fotovoltaiche di piccole dimensioni, gli inverter RPS Endurance includono tutti i componenti e le funzioni necessarie per un collegamento diretto delle unità a un singolo avvolgimento di trasformatore di media tensione ( configurazione stand-alone ). Sul lato CC, ogni inverter può essere collegato ad un combinatore CC esterno con un numero configurabile di ingressi e una flessibile configurazione di messa a terra. In alternativa, è disponibile una semplice e compatta soluzione con scatola dei fusibili per generatori FV messi a terra, con un numero massimo di 6 ingressi CC per polo per ciascuna unità Endurance. Nella configurazione stand-alone, due unità possono essere collegate ad un trasformatore a tre avvolgimenti convenzionale per formare una stazione inverter da 1t - 1,125 MWac. Typical System Configuration for MWac Inverter Station Solution with 2 RPS Endurance. Tipica configurazione di sistema per stazioni inverter da 1 1,125 MWac con 2 RPS Endurance. *external fusebox can be connected to inverter inputs of ungrounded PV generator pole(s) *la scatola dei fusibili esterna può essere collegata agli ingressi inverter dei poli di generatori fotovoltaici senza messa a terra

12 12 RPS ND RPS ND x RPS ND 0500 (M/S) RPS ND x RPS ND 0535 (M/S) Number of inverter units / Numero di inverter Input Ratings / Ingresso Recommended PV generator power Potenza di picco PV Field suggerita kwp Maximum input current / Corrente di ingresso max. A Maximum input voltage / Tensione di ingresso max. V 1000 MPPT range / Intervallo MPPT V Number of MPP Trackers / Numero di MPP tracker - 1 1* 1 1* Output Ratings / Uscita Mains voltage / Tensione di rete V 360 (IT-grid) / 360 (rete IT) 386 (IT-grid) / 386 (rete IT) Mains frequency / Frequenza di rete Hz 50 / 60 Rated power / Potenza nominale kva Max. / nom. power at T a <= 25 C Max. power at Tamb = 25 C kva Rated current / Corrente nominale A Max. / nom. current / Corrente max./nom. A Power factor range / Fattore di potenza - controllable 0.0i c (nominal > 0.99 at rated power) controllabile 0.0i c (nominale > 0.99 alla potenza nominale) Current harmonic distortion Distorsione armonica corrente % < 3 at nom. power / < 3 alla potenza nominale Auxiliary Power Supply / Alimentazione ausiliaria % 230 V, external, TN-S-grid / 230 V, esterna, rete TN-S Efficiency / Rendimento Maximum efficiency / Rendimento massimo % 98.6 European efficiency / Rendimento Europeo % 98.4 Standby Power Consumption / Standby Power Consumption W < 25 < 50 < 25 < 50 Mechanical Data / Dati meccanici Dimensions (WxHxD) / Dimensioni (LxAxP) mm 1216 x 2120 x x 2120 x 608** 1216 x 2120 x x 2120 x 608** Weight (approx.) / Peso (circa) kg Ambient Specification / Ambiente Protection class / Classe di protezione - Ambient operating temperature range Gamma di funzionamento temperatura ambiente Indoor rated (Power electronics, switchgear, controls: IP54) Idoneità per installazione indoor (elettronica di potenza, interruttori, controlli: IP54) C *** Rel. Humidity / Umidità relativa % (non-condensing) / (senza condensa) Max. Altitude / Altitudine max. m 4000 (derating above 1000 m) / 4000 (declassamento oltre i 1000 m) Req. Air flow rate / Portata aria richiesta m 3 /h Environm. conditions acc. to EN Condizioni ambientali in conf. alla EN K3, 3B1, 3C1, 3S2, 3M1 (unless deviating specifications provided) 3K3, 3B1, 3C1, 3S2, 3M1 (in assenza di specifiche diverse) Protection and Monitoring / Protezione e monitoraggio Overvoltage protection / Protezione da sovratensione - EN Typ 2, IEC Class II on mains and generator side EN Tipo 2, IEC Classe II lato rete e generatore Grid monitoring / Monitoraggio di rete - Adjustable voltage and frequency range / Intervallo di tensione e frequenza regolabile PV generator connection / Connessione generatore FV - Insulation monitoring, polarity reversal protection, dc load-break switch (remote release) Monitoraggio dell isolamento, protezione dall inversione di polarità, interruttore del carico CC (scatto a distanza) Interfaces / Interfacce Communication interface Interfaccia di comunicazione - RS-485 (ModBus or proprietary), Options: ModBus /TCP, CAN, Profibus RS-485 (ModBus o brevettato), Opzioni: ModBus / TCP, CAN, Profibus CStandards and Certificationsc / Certificazioni Safety / Sicurezza /95/EC, IEC , IEC Electromagnetic compatibility Compatibilità elettromagnetica /108/EC, EN , EN , EN , EN Grid management / Gestione rete - BDEW, CNE2013, SAGC2012, Ord. 74/2013, P.O. 12.3, Arrête du 23 Avril 2008 * common external dc combiner required / necessario combinatore CC esterno comune ** per inverter unit, excluding ext. dc combiner / per unità inverter, escluso combinatore CC esterno *** -20 C +50 C at rated power for Vdc < 700 V / -20 C +50 C alla potenza nominale per Vdc < 700 V BDEW (in preparation / in preparazione), CNE2013, SAGC2012, Ord. 74/2013, P.O. 12.3, Arrête du 23 Avril 2008

13 13 RPS ND RPS ND x RPS ND 0555 (M/S) RPS ND x RPS ND 0560 (M/S) Number of inverter units / Numero di inverter Input Ratings / Ingresso Recommended PV generator power Potenza di picco PV Field suggerita kwp Maximum input current / Corrente di ingresso max. A Maximum input voltage / Tensione di ingresso max. V 1000 MPPT range / Intervallo MPPT V Number of MPP Trackers / Numero di MPP tracker - 1 1* 1 1* Output Ratings / Uscita Mains voltage / Tensione di rete V 400 (IT-grid) / 400 (rete IT) 406 (IT-grid) / 406 (rete IT) Mains frequency / Frequenza di rete Hz 50 / 60 Rated power / Potenza nominale kva Max. / nom. power at T a <= 25 C Max. power at Tamb = 25 C kva Rated current / Corrente nominale A Max. / nom. current / Corrente max./nom. A Power factor range / Fattore di potenza - controllable 0.0i c (nominal > 0.99 at rated power) controllabile 0.0i c (nominale > 0.99 alla potenza nominale) Current harmonic distortion Distorsione armonica corrente % < 3 at nom. power / < 3 alla potenza nominale Auxiliary Power Supply / Alimentazione ausiliaria % 230 V, external, TN-S-grid / 230 V, esterna, rete TN-S Efficiency / Rendimento Maximum efficiency / Rendimento massimo % 98.6 European efficiency / Rendimento Europeo % 98.4 Standby Power Consumption / Standby Power Consumption W < 25 < 50 < 25 < 50 Mechanical Data / Dati meccanici Dimensions (WxHxD) / Dimensioni (LxAxP) mm 1216 x 2120 x x 2120 x 608** 1216 x 2120 x x 2120 x 608** Weight (approx.) / Peso (circa) kg Ambient Specification / Ambiente Protection class / Classe di protezione - Ambient operating temperature range Gamma di funzionamento temperatura ambiente Indoor rated (Power electronics, switchgear, controls: IP54) Idoneità per installazione indoor (elettronica di potenza, interruttori, controlli: IP54) C *** Rel. Humidity / Umidità relativa % (non-condensing) / (senza condensa) Max. Altitude / Altitudine max. m 4000 (derating above 1000 m) / 4000 (declassamento oltre i 1000 m) Req. Air flow rate / Portata aria richiesta m 3 /h Environm. conditions acc. to EN Condizioni ambientali in conf. alla EN K3, 3B1, 3C1, 3S2, 3M1 (unless deviating specifications provided) 3K3, 3B1, 3C1, 3S2, 3M1 (in assenza di specifiche diverse) Protection and Monitoring / Protezione e monitoraggio Overvoltage protection / Protezione da sovratensione - EN Typ 2, IEC Class II on mains and generator side EN Tipo 2, IEC Classe II lato rete e generatore Grid monitoring / Monitoraggio di rete - Adjustable voltage and frequency range / Intervallo di tensione e frequenza regolabile PV generator connection / Connessione generatore FV - Insulation monitoring, polarity reversal protection, dc load-break switch (remote release) Monitoraggio dell isolamento, protezione dall inversione di polarità, interruttore del carico CC (scatto a distanza) Interfaces / Interfacce Communication interface Interfaccia di comunicazione - RS-485 (ModBus or proprietary), Options: ModBus /TCP, CAN, Profibus RS-485 (ModBus o brevettato), Opzioni: ModBus / TCP, CAN, Profibus CStandards and Certificationsc / Certificazioni Safety / Sicurezza /95/EC, IEC , IEC Electromagnetic compatibility Compatibilità elettromagnetica /108/EC, EN , EN , EN , EN Grid management / Gestione rete - BDEW, CNE2013, SAGC2012, Ord. 74/2013, P.O. 12.3, Arrête du 23 Avril 2008 * common external dc combiner required / necessario combinatore CC esterno comune ** per inverter unit, excluding ext. dc combiner / per unità inverter, escluso combinatore CC esterno *** -20 C +50 C at rated power for Vdc < 700 V / -20 C +50 C alla potenza nominale per Vdc < 700 V BDEW (in preparation / in preparazione), CNE2013, SAGC2012, Ord. 74/2013, P.O. 12.3, Arrête du 23 Avril 2008

14

15 15 DC combiners for all needs. Combinatori CC per ogni necessità. A set of standard DC combiners is available to optimally match a wide range of PV string configurations with RPS Endurance inverters. DC combiners are available for single inverters in stand-alone configuration, as well as for Master-Slave configurations of two inverter units with a common dc input. RPS Endurance inverters can also be connected to customer-supplied dc combiners. Customized dc combiners are available on request, including also options for dc zone monitoring. Please contact for your special requirements. È disponibile una serie di combinatori CC standard per abbinare in modo ottimale una vasta gamma di configurazioni di stringhe FV agli inverter RPS Endurance. I combinatori CC sono disponibili per singoli inverter in configurazione stand-alone, nonché per configurazioni master-slave di due inverter con ingresso CC comune. Gli inverter Endurance RPS possono anche essere collegati a combinatori CC forniti dal cliente. Sono disponibili su richiesta combinatori CC personalizzati, compresivi anche di opzioni per il monitoraggio della zona CC. Contattare per i propri requisiti speciali. DC Combiner Twin M/S Grounded PV Generator Combinatore CC Twin M/S Generatore FV messo a terra DC combiner for two parallel-connected RPS Endurance units in M/S configuration. For negative grounded PV generator. Ground-fault detection and interruption integrated in dc combiner 12 Inputs up to 240 mm 2, Fuse size up to 315 A, 4 fused outputs to each RPS Endurance inverter unit. Combinatore CC per due RPS Endurance collegati in parallelo in configurazione M/S. Per generatori FV con messa a terra negativa. Rilevamento dei guasti di messa a terra e interruzione integrata nel combinatore CC 12 ingressi fino a 240 mm 2, fusibili fino a 315 A, 4 uscite con fusibili per ciascun inverter RPS Endurance. DC Combiner Twin M/S Floating PV Generator Combinatore CC Twin M/S Generatore FV flottante DC Combiner for two parallel-connected RPS Endurance units in M/S configuration. For floating PV generator. 12 Inputs up to 240 mm 2 / Fuse size up to 315 A, 4 fused outputs to each RPS Endurance inverter unit. Combinatore CC per due RPS Endurance collegati in parallelo in configurazione M/S. Per generatori FV flottanti. 12 ingressi fino a 240 mm 2 / fusibili fino a 315 A, 4 uscite con fusibili per ciascun inverter RPS Endurance. DC Fusebox for Single RPS Endurance unit (Stand-Alone Configuration) Scatola fusibili CC per singola unità RPS Endurance (configurazione stand-alone) For grounded and floating PV generator. D In case of grounded PV generator, GFDI integrated into 0,71 RPS Endurance unit. In case of floating PV generator, are generally required two protect positive and negative inputs 6 Inputs up to 240mm 2, Fuse size up to 400 A D-D 400 F 95 F-F Per generatori FV messi a terra e flottanti. In caso di generatori FV messi a terra, GFDI integrato nell unità RPS Endurance. In caso di generatori FV flottanti, sono generalmente richiesti due ingressi positivi e negativi di protezione 6 ingressi fino a 240 mm 2, fusibili fino a 400 A D F

16

17 17 RPS Station The perfect home for RPS Endurance inverters. RPS Station La casa perfetta per gli inverter RPS Endurance. RPS Endurance inverters are available in readyto-deploy RPS Station turn-key PV stations that integrate inverters, auxiliaries and, optionally, equipment for medium-voltage grid connection into a transportable shelter. A number of regionalized solutions are available including marine containers and concrete-base shelter cabins, to provide an optimum match to installation and transport requirements of each individual project. Thanks to the very compact design of the RPS Endurance inverter units, it is possible to achieve a power rating of up to 2.25 MWac in the reduced footprint of a 20 ft ISO container, helping to greatly reduce sitework and logistics effort. Gli inverter Endurance RPS sono disponibili in stazioni fotovoltaiche RPS Station fornite chiavi in mano che integrano inverter, dispositivi ausiliari e, opzionalmente, apparecchiature per il collegamento alla rete a media tensione in un riparo trasportabile. Sono disponibili numerose soluzioni adattate alle esigenze delle varie regioni, quali container marini e cabine con base in cemento, per un adeguamento ottimale ai requisiti di installazione e trasporto di ogni singolo progetto. Grazie al design estremamente compatto degli inverter RPS Endurance, è possibile conseguire una potenza massima di 2,25 MWac nell ingombro ridotto di un container ISO da 20 pedi, contribuendo a ridurre notevolmente i lavori in cantiere e lo sforzo logistico. RPS Station ICON ND 20 LV Solution Example 20 ft ISO marine container design Integration of up to 4 units RPS ND Rated power: 2250 kwac ( 4 x RPS ND 0560) Maximum power: up to 2592 kwac (4 x RPS ND 0560, including overload capacity) Forced-air ambient cooling control, auxiliary power supply, monitoring and dc combiners included Optionally supplied with external 2.0 or 2.5 MVA medium voltage-transformer and switchgear up to 36 kv Esempio di realizzazione Design con container marini ISO da 20 piedi Integrazione di un massimo di 4 unità RPS ND Potenza nominale: 2250 kwac (4 x RPS ND 0560) Potenza massima: fino a 2592 kwac (4 x RPS ND 0560, inclusa capacità di sovraccarico) Controllo raffreddamento forzato aria ambiente, alimentazione ausiliaria, monitoraggio e combinatori CC inclusi Equipaggiamento facoltativo con trasformatore di media tensione esterno da 2,0 o 2,5 MVA e quadri fino a 36 kv

18 Branches and facilities Filiali e stabilimenti Our branches / Le nostre filiali Canada France United Kingdom Deutschland Österreich Italia Türkiye China USA Brasil Tecnotrans South Africa India South East Asia Vietnam Australia New Zealand Photovoltaic USA France Vectron Italy China Headquarters Vectron facility Production facilities Commercial Service Brasil Spain South Africa India

19 worldwide network. Rete mondiale. Australia 2, Cox Place Glendenning NSW 2761 Locked Bag 1000 Plumpton NSW 2761 Tel. (+ 61) Fax (+ 61) Brasil Travessa Cláudio Armando 171 Bloco 3 - CEP Bairro Assunção São Bernardo do Campo - São Paulo Tel. (+55) Fax (+55) Canada Jane Street - Concord, Ontario L4K 4L6 Tel. (+1) Fax (+1) China Drives (Shanghai) Co., Ltd. #68, Hui-Lian Road, QingPu District, Shanghai, China, Ph. (+86) Fax (+86) Deutschland Industrial, Mobile, Wind Sperberweg Neuss Tel. +49 (0) Fax +49 (0) Industrial, Photovoltaic Europark Fichtenhain B Krefeld Tel. +49 (0) Fax +49 (0) España Industrial, Mobile, Wind Tecnotrans S.A. Pol. Ind. Zona Franca sector C, calle F, n Barcelona Tel. (+34) Fax (+34) Photovoltaic Renewable Power Conversion Spain, SL Ribera del Loira, 46 - Edificio Madrid Tel. (+34) Fax (+34) France 14 Rue Eugène Pottier Zone Industrielle de Moimont II Marly la Ville Tel. (+33) Fax (+33) India Industrial Transmission PVT ltd. Survey No. 528, Perambakkam High Road Mannur Village, Sriperambudur Taluk, Chennai , Tamil Nadu Tel. +91(0) Fax +91(0) Mobile, Wind Transmission PVT ltd. PLOT AC7-AC11 Sidco Industrial Estate Thirumudivakkam - Chennai Tel. +91(0) Fax +91(0) Photovoltaic Renewable Power Conversion India (P) Ltd No. 543, 14th Cross, 4th Phase, Peenya Industrial Area, Bangalore Tel /15 - Fax Italia Industrial, Photovoltaic Via Sandro Pertini lotto 7b Carpiano (Milano) Tel. (+39) Fax (+39) Mechatronic Research Via F. Zeni Rovereto (Trento) Tel. (+39) /36 - Fax (+39) New Zealand 88 Hastie Avenue, Mangere Bridge, Auckland 2022, New Zealand - PO Box 11795, Ellerslie Tel. (+64) Fax (+64) Österreich Molkereistr 4 - A-2700 Wiener Neustadt Tel. (+43) Fax (+43) South East Asia 24 Pioneer Crescent #02-08 West Park Bizcentral - Singapore, Tel. (+65) Fax. (+65) South Africa 55 Galaxy Avenue, Linbro Business Park - Sandton Tel. (+27) OR - Fax (+27) Türkiye Atatürk Organize Sanayi Bölgesi, Sk. No. 9, Çigli - Izmir Tel. +90 (0) (pbx) Fax +90 (0) United Kingdom Industrial, Photovoltaic Unit 7, Colemeadow Road North Moons Moat - Redditch, Worcestershire B98 9PB Tel. (+44) Fax (+44) Mobile, Wind 3-7 Grosvenor Grange, Woolston Warrington - Cheshire WA1 4SF Tel. (+44) Fax (+44) USA 3541 Hargrave Drive Hebron, Kentucky Tel. (+1) Fax (+1) Vietnam Lot C-9D-CN My Phuoc Industrial Park 3 Ben Cat - Binh Duong Province Tel. (+84) Fax (+84)

20 has been designing and developing innovative and reliable power transmission and control solutions for industry, mobile machinery and renewable energy applications since Dal 1956 progetta e realizza soluzioni innovative e affidabili per il controllo e la trasmissione di potenza nell industria, nelle macchine operatrici semoventi e per le energie rinnovabili. HEADQUARTERS Riduttori S.p.A. Via Giovanni XXIII, 7/A Lippo di Calderara di Reno Bologna (Italy) tel: fax: bonfiglioli@bonfiglioli.com VE_CAT_REND_STD_ENG-ITA_R02_1

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

RPS TL System. Soluzioni per l energia solare Solutions for solar energy Soluzioni per l energia solare Solutions for solar energy RPS TL da 280 kwp a 1460 kwp RPS TL from 280 kwp to 1460 kwp RPS TL System L elevata affidabilità e la modularità della costruzione sono solo alcuni

Dettagli

RPS TL. Solutions for solar energy Soluzioni per l energia solare

RPS TL. Solutions for solar energy Soluzioni per l energia solare Solutions for solar energy Soluzioni per l energia solare RPS TL from 280 kwp to 1580 kwp RPS TL da 280 kwp a 1580 kwp RPS TL. The excellent productivity level and system availability of Bonfiglioli s

Dettagli

RPS TL-4Q. Power conditioning inverters for large storage systems Inverter di condizionamento della potenza per grandi sistemi di accumulo + -

RPS TL-4Q. Power conditioning inverters for large storage systems Inverter di condizionamento della potenza per grandi sistemi di accumulo + - RPS TL4Q Power conditioning inverters for large storage systems Inverter di condizionamento della potenza per grandi sistemi di accumulo + 2015/2016 Power, control and green solutions 3 RPS TL4Q DCAC power

Dettagli

Soluzioni per l energia solare Solutions for solar energy

Soluzioni per l energia solare Solutions for solar energy Multi MPPT 270V RPS TL 0280 0340 0510 0680 0850 kwp 280 340 510 680 850 Corrente di ingresso max. / Max. input current A 600 700 1050 1400 1750 Intervallo MPPT / MPPT range V 425... 875 N. MPPT 2 2 3 4

Dettagli

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer Inverter solare monofase con trasformatore ngle-phase solar inverter with transformer La soluzione migliore nel caso in cui esigenze normative o funzionali di modulo, d impianto o di rete, richiedano la

Dettagli

RPS Station. Solutions for solar energy Soluzioni per l energia solare

RPS Station. Solutions for solar energy Soluzioni per l energia solare RPS Station Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 RPS Station. s RPS Stations provide turnkey solutions for complete photovoltaic field

Dettagli

SCB String Connection Box. Solutions for solar energy Soluzioni per l energia solare

SCB String Connection Box. Solutions for solar energy Soluzioni per l energia solare SCB String Connection Box Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 Perfect coverage for high efficiency: String Connection Box. La copertura

Dettagli

Sìstema UPS trifase indipendente. PowerWave 33 60 500 kw Prestazioni imbattibili

Sìstema UPS trifase indipendente. PowerWave 33 60 500 kw Prestazioni imbattibili Sìstema UPS trifase indipendente PowerWave 33 60 500 kw Prestazioni imbattibili PowerWave 33: un concentrato di potenza Da sempre ABB rappresenta lo standard globale per le soluzioni di continuità di alimentazione.

Dettagli

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare RPS TL Modular Outdoor System Solutions for solar energy Soluzioni per l energia solare 2013/2014 Power, control and green solutions 3 RPS TL Modular Outdoor. The RPS TL Modular Outdoor system is a new

Dettagli

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare RPS TL Modular Outdoor System Solutions for solar energy Soluzioni per l energia solare 2014/2015 Power, control and green solutions 3 RPS TL Modular Outdoor. The RPS TL Modular Outdoor system is a new

Dettagli

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni Riduttori epicicloidali a gioco ridotto ad altissime prestazioni TENIAMO IL MONDO IN MOVIMENTO Nel suo sforzo di diventare un partner di classe mondiale, Bonfiglioli è leader nella trasmissione di potenza

Dettagli

Inverter centralizzati ABB PVS800 da 100 a 1000 kw

Inverter centralizzati ABB PVS800 da 100 a 1000 kw Inverter solari Inverter centralizzati ABB PVS800 da 100 a 1000 kw Gli inverter centralizzati ABB sono in grado di assicurare nuovi livelli di affidabilità, efficienza e semplicità di installazione. Questi

Dettagli

RPS 450 Compact System. Solutions for solar energy Soluzioni per l energia solare

RPS 450 Compact System. Solutions for solar energy Soluzioni per l energia solare RPS 45 Compact System Solutions for solar energy Soluzioni per l energia solare 3/4 Power, control and green solutions 3 RPS 45 Compact. s RPS 45 Compact series solar inverters represent a ready to use,

Dettagli

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni Riduttori epicicloidali a gioco ridotto ad altissime prestazioni BONFIGLIOLI SOLUTIONS 2 3 TENIAMO IL MONDO IN MOVIMENTO MECCATRONICA - LA SFIDA PER COSTRUIRE IL NOSTRO SUCCESSO Più veloci, più efficienti,

Dettagli

SUNWAY M XS. Inverter solare monofase senza trasformatore. Transformerless Single-phase Solar Inverter

SUNWAY M XS. Inverter solare monofase senza trasformatore. Transformerless Single-phase Solar Inverter Inverter solare monofase senza trasformatore Transformerless Single-phase Solar Inverter La soluzione per impianti da 2 a 9 kwp: un inverter leggero per l assenza di trasformatore per massimizzare il rendimento

Dettagli

Servizi pre e post vendita

Servizi pre e post vendita Servizi pre e post vendita 3 Sempre al tuo fianco per offrirti il miglior servizio possibile. Nella filosofia aziendale, la piena soddisfazione del cliente e la creazione di una relazione solida e duratura

Dettagli

AIR CONDITIONING & HEATING FOR HEAVY-DUTY EQUIPMENT

AIR CONDITIONING & HEATING FOR HEAVY-DUTY EQUIPMENT AIR CONDITIONING & HEATING FOR HEAVY-DUTY EQUIPMENT Company Profile S.E.A. specializes in air conditioning for a wide range of applications, such as construction vehicles, agricultural vehicles, military

Dettagli

RPS TL System. Solutions for solar energy Soluzioni per l energia solare

RPS TL System. Solutions for solar energy Soluzioni per l energia solare RPS TL System Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 RPS TL. The excellent productivity level and system availability of s RPS TL inverter

Dettagli

RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare

RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare RPS Endurance System Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 RPS Endurance A compact powerhouse. Bonfiglioli s cutting-edge RPS Endurance

Dettagli

Soluzioni a tetto per l energia solare

Soluzioni a tetto per l energia solare Soluzioni a tetto per l energia solare Power, control and green solutions 3 L esperienza di un grande Gruppo al tuo servizio. Fondato nel 1956, da oltre 25 anni il Gruppo progetta e distribuisce in tutto

Dettagli

RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare

RPS Endurance System. Solutions for solar energy Soluzioni per l energia solare RPS Endurance System Solutions for solar energy Soluzioni per l energia solare 2013/2014 Power, control and green solutions 3 RPS Endurance. expands its product offering with the introduction of the new

Dettagli

Soluzioni per applicazioni con gru

Soluzioni per applicazioni con gru Soluzioni per applicazioni con gru 1 2 3 Soluzioni per applicazioni con gru Con oltre 60 anni di esperienza nelle soluzioni integrate per la trasmissione di potenza, Bonfiglioli offre una gamma completa

Dettagli

PVI-5000-OUTD PVI-6000-OUTD

PVI-5000-OUTD PVI-6000-OUTD PVI5000OUTD PVI6000OUTD CARATTERISTICHE GENERALI MODELLI DA ESTERNO PVI5000OUTD PVI6000OUTD PVI5000OUTDUS PVI6000OUTDUS Versione per Europa ed APAC Versione per Nord America 46 AURORA UNO UNO TRIO Progettato

Dettagli

RPS TL System. Solutions for solar energy Soluzioni per l energia solare

RPS TL System. Solutions for solar energy Soluzioni per l energia solare RPS TL System Solutions for solar energy Soluzioni per l energia solare 2013/2014 Power, control and green solutions 3 RPS TL. The excellent productivity level and system availability of s RPS TL inverter

Dettagli

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare

RPS TL Modular Outdoor System. Solutions for solar energy Soluzioni per l energia solare RPS TL Modular Outdoor System Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 RPS TL Modular Outdoor. The RPS TL Modular Outdoor system is a new

Dettagli

IL CERVELLO DEGLI IMPIANTI FV. Tecnologia all avanguardia per progetti di successo

IL CERVELLO DEGLI IMPIANTI FV. Tecnologia all avanguardia per progetti di successo IL CERVELLO DEGLI IMPIANTI FV Tecnologia all avanguardia per progetti di successo Valerio Natalizia, SMA Italia Next Wave PV, elemens Milano, 22 Maggio 2013 SMA: il gruppo I numeri Gamma di prodotti completa

Dettagli

RPS Station. Solutions for solar energy Soluzioni per l energia solare

RPS Station. Solutions for solar energy Soluzioni per l energia solare RPS Station Solutions for solar energy Soluzioni per l energia solare 2013/2014 Power, control and green solutions 3 RPS Station. s RPS Stations provide turnkey solutions for complete photovoltaic field

Dettagli

L inverter SMA, il cuore di ogni impianto fotovoltaico

L inverter SMA, il cuore di ogni impianto fotovoltaico L inverter SMA, il cuore di ogni impianto fotovoltaico L efficienza di un impianto fotovoltaico dipende dall efficienza dell inverter. Il suo compito è di trasformare la corrente continua delle celle solari

Dettagli

Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly

Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly MAKING MODERN LIVING POSSIBLE Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly Per impianti residenziali da 2,0 kw a 4,6 kw 97,3% di efficienza massima Prestazioni

Dettagli

A-C-F Servo gearmotors

A-C-F Servo gearmotors A-C-F Servo gearmotors PRODUCT 3 Indice 5 Una nuova generazione di motoriduttori 6 Vantaggi 7 Esempi di applicazione 8 Gamma 9 Esempi di combinazioni disponibili e relative prestazioni 10 Presenza globale

Dettagli

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer Inverter solare monofase con trasformatore Single-phase solar inverter with transformer La soluzione migliore nel caso in cui esigenze normative o funzionali di modulo, d impianto o di rete, richiedano

Dettagli

IPS 100 3000VA DC/AC INVERTER. Specifiche tecniche Data sheet. 24 110Vdc 230V 50 Hz

IPS 100 3000VA DC/AC INVERTER. Specifiche tecniche Data sheet. 24 110Vdc 230V 50 Hz IPS 100 3000VA DC/AC INVERTER 24 110Vdc 230V 50 Hz Specifiche tecniche Data sheet SPECIFICA TECNICA INVERTER 24Vdc 230V-50Hz MODELLO MODEL 100 200 500 1000 2000 3000 dati d'ingresso Input data tensione

Dettagli

TACTÒ TASTIERA EFFETTO HALL KEY PAD HALL EFFECT

TACTÒ TASTIERA EFFETTO HALL KEY PAD HALL EFFECT TACTÒ TASTIERA EFFETTO HALL KEY PAD HALL EFFECT edizione/edition 04-03 DESCRIZIONE DESCRIPTION DESCRIZIONE La nuova tastiera COBO è stata studiata per ottimizzare gli spazi all interno delle cabine moderne.

Dettagli

Active Cube 8. La soluzione ad alta potenza PRODOTTO

Active Cube 8. La soluzione ad alta potenza PRODOTTO Active Cube 8 La soluzione ad alta potenza PRODOTTO 3 Active Cube 8 La soluzione ad alta potenza. La nuova serie di inverter Active Cube 8 di Bonfiglioli impone nuovi standard tecnologici per un vasto

Dettagli

A-C-F Servo gearmotors

A-C-F Servo gearmotors A-C-F Servo gearmotors PRODUCT 3 Indice 5 UNA NUOVA GENERAZIONE DI MOTORIDUTTORI 6 VANTAGGI 7 ESEMPI DI APPLICAZIONE 8 GAMMA 9 ESEMPI DI COMBINAZIONI DISPONIBILI E RELATIVE PRESTAZIONI 10 PRESENZA GLOBALE

Dettagli

tecnologie ecosostenibili applicate www.htgitaly.eu INVERTER HTG 40 MP

tecnologie ecosostenibili applicate www.htgitaly.eu INVERTER HTG 40 MP INVERTER HTG 40 MP L inverter HTG40 MP è un inverter/caricabatteria ad alta frequenza progettato per soddisfare tutte le esigenze che il mercato STORAGE per impianti fotovoltaici oggi giorno richiede.

Dettagli

Sunways Solar Inverter AT 5000, AT 4500, AT 3600, AT 3000 e AT 2700

Sunways Solar Inverter AT 5000, AT 4500, AT 3600, AT 3000 e AT 2700 OLAR INVERTER Sunways Solar Inverter AT 5000, AT 4500, AT 3600, AT 3000 e AT 2700 Grazie alla topologia HERIC con innovativo circuito FP (a potenziale fisso), i nuovi Solar Inverter AT di Sunways offrono

Dettagli

AxSun INVERTER PER APPLICAZIONI FOTOVOLTAICHE. Manuale d Uso

AxSun INVERTER PER APPLICAZIONI FOTOVOLTAICHE. Manuale d Uso AxSun INVERTER PER APPLICAZIONI FOTOVOLTAICHE Manuale d Uso Caratteristiche Tecniche Filtri di ingresso DC Moduli Inverter Interruttori di ingresso DC Interruttori di uscita AC Filtri risonanti Filtri

Dettagli

Integrated Comfort SyStemS

Integrated Comfort SyStemS Integrated Comfort Systems EST (Energy Saving Technology) è una tecnologia applicata ai ventilconvettori e cassette EURAPO che consente di ottenere assorbimenti elettrici estremamente contenuti e una modulazione

Dettagli

Power Transmission Solutions

Power Transmission Solutions Power Transmission Solutions 1 Bonfiglioli solutions 3 Power Transmission Solutions 5 UN UNICO FORNITORE PER TUTTE LE APPLICAZIONI INDUSTRIALI 6 SOLUZIONI PER I NOSTRI CLIENTI 9 9 10 10 11 11 12 12 13

Dettagli

CERTIFICATO IL SISTEMA QUALITÀ DI THE QUALITY SYSTEM OF. BONFIGLIOLI RIDUTTORI S.p.A.

CERTIFICATO IL SISTEMA QUALITÀ DI THE QUALITY SYSTEM OF. BONFIGLIOLI RIDUTTORI S.p.A. CERTIFICATO Nr 50 100 2568 - Rev. 11 Si attesta che / This is to certify that IL SISTEMA QUALITÀ DI THE QUALITY SYSTEM OF SEDE LEGALE E OPERATIVA: REGISTERED OFFICE AND OPERATIONAL SITE: VIA GIOVANNI XXIII

Dettagli

RPS Station. Solutions for solar energy Soluzioni per l energia solare

RPS Station. Solutions for solar energy Soluzioni per l energia solare RPS Station Solutions for solar energy Soluzioni per l energia solare 2015/2016 Power, control and green solutions 3 RPS Station. Bonfiglioli s RPS Stations provide turnkey solutions for complete photovoltaic

Dettagli

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer Inverter solare monofase con trasformatore Single-phase solar inverter with transformer La soluzione migliore nel caso in cui esigenze normative o funzionali di modulo, d impianto o di rete, richiedano

Dettagli

RPS 450 Compact System. Solutions for solar energy Soluzioni per l energia solare

RPS 450 Compact System. Solutions for solar energy Soluzioni per l energia solare RPS 45 Compact System Solutions for solar energy Soluzioni per l energia solare 5/6 Power, control and green solutions 3 RPS 45 Compact. Bonfiglioli s RPS 45 Compact series solar inverters represent a

Dettagli

ISAC. Company Profile

ISAC. Company Profile ISAC Company Profile ISAC, all that technology can do. L azienda ISAC nasce nel 1994, quando professionisti con una grande esperienza nel settore si uniscono, e creano un team di lavoro con l obiettivo

Dettagli

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS I sistemi mod. i-léd SOLAR permettono di alimentare un carico sia in bassa tensione 12-24V DC, sia a 230v AC, tramite alimentazione

Dettagli

3/H. Riduttore combinato

3/H. Riduttore combinato 3/H Riduttore combinato 2 Riduttori combinati - caratteristiche La soluzione 3/H combina i vantaggi tecnologici, prestazionali e di efficienza della serie di riduttori epicicloidali, con la robustezza,

Dettagli

SPECIFICA TECNICA. Leonardo String Box Control

SPECIFICA TECNICA. Leonardo String Box Control CARATTERISTICHE SPECIFICA TECNICA Leonardo String Box Control PARAMETRI INGRESSO Range di tensione in Ingresso V 200 900 Max. corrente di stringa A 16 Numero di canali di misura 10 Numero stringhe in ingresso

Dettagli

300S Slewing Drives per applicazioni industriali

300S Slewing Drives per applicazioni industriali 300S Slewing Drives per applicazioni industriali PRODUCT 3 300S: il riduttore per rotazioni industriali 300S è il riduttore epicicloidale di Bonfiglioli specificatamente pensato per le applicazioni industriali

Dettagli

Tabella di scelta tabella di scelta

Tabella di scelta tabella di scelta 22 23 01 Inverter tl Tabella di scelta tabella di scelta Modello sirio 1500 sirio 2000 sirio 2800 codice prodotto 6PHV1K51Xa 6PHV2K01Xa 6PHV2K81Xa max 1900 Wp min 1000 Wp max 2500 Wp min 1400 Wp max 3500

Dettagli

97,3% Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly. Per impianti residenziali da 2,0 kw a 4,6 kw

97,3% Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly. Per impianti residenziali da 2,0 kw a 4,6 kw MAKING MODERN LIVING POSSIBLE Gamma di inverter fotovoltaici Danfoss DLX Prestazioni e flessibilità in un design user-friendly Per impianti residenziali da 2,0 kw a 4,6 kw 97,3% di efficienza massima Prestazioni

Dettagli

www.microset.net ALIMENTATORI SWITCHING SWITCHING POWER SUPPLY mod. PTS 124 mod. PTS 150 mod. PTS 124 mod. PTS 150

www.microset.net ALIMENTATORI SWITCHING SWITCHING POWER SUPPLY mod. PTS 124 mod. PTS 150 mod. PTS 124 mod. PTS 150 1 www.microset.net NUOVA SERIE DI ALIMENTATORI SWITCHING, PICCOLI - POTENTI LEGGERI - AFFIDABILI NEW POWER SUPPLY FAMILY SWITCH MODE - HIGH EFFICIENCY SMALL SIZE - POWERFUL - RELIABLE mod. PTS 124 mod.

Dettagli

Ingecon Sun Power Max 315 TL

Ingecon Sun Power Max 315 TL Ingecon Sun Power Max 315 TL Caratteristiche generali Senza trasformatore di bassa tensione per connessione ad alta efficienza alla rete di media tensione. Dispone di 2 sistemi avanzati di monitoraggio

Dettagli

Il dispositivo per massimizzare l autoconsumo di energia

Il dispositivo per massimizzare l autoconsumo di energia PowerRouter Accumulo e gestione intelligente dell energia Il dispositivo per massimizzare l autoconsumo di energia Il PowerRouter rappresenta la soluzione ottimale per sfruttare l energia prodotta da un

Dettagli

Photovoltaic Inverters with transformer Inverter fotovoltaici con trasformatore

Photovoltaic Inverters with transformer Inverter fotovoltaici con trasformatore Photovoltaic Inverters with transformer Inverter fotovoltaici con trasformatore Catalogue 2011 Catalogo 2011 Welcome Welcome to the world of Valenia ondo Valenia Clean Energy for a better world. Valenia

Dettagli

Attuatore a relè Manuale di istruzioni

Attuatore a relè Manuale di istruzioni Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per

Dettagli

Attuatore a relè Manuale di istruzioni

Attuatore a relè Manuale di istruzioni Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per

Dettagli

Le Soluzioni SMA per gli impianti non connessi alla rete. SMA Solar Technology

Le Soluzioni SMA per gli impianti non connessi alla rete. SMA Solar Technology Le Soluzioni SMA per gli impianti non connessi alla rete Schema base sistema off-grid di SMA SIC-50 SI SB WB AC2 AC1 Carico 2 Sunny Island: il gestore di un sistema Off-Grid 3 Gestione dell energia e dei

Dettagli

Plant Logging & Monitoring

Plant Logging & Monitoring Plant Logging & Monitoring Solutions for solar energy Soluzioni per l energia solare 01101 00011 11101 01101 00101 11101 11101 01101 00101 11101 01101 00101 00011 11101 01101 00101 11101 01101 01101 00011

Dettagli

3/H. Riduttore combinato PRODUCT

3/H. Riduttore combinato PRODUCT 3/H Riduttore combinato PRODUCT 3 Indice 4 Riduttori combinati - caratteristiche 5 Campi di applicazione 6 Presentazione prodotto 7 Varianti 8 Opzioni - Accessori 9 Soluzioni specifiche 10 Dimensioni

Dettagli

Soluzioni per trattamento acque

Soluzioni per trattamento acque Soluzioni per trattamento acque SETTORE 3 LE SOLUZIONI INDUSTRIALI BONFIGLIOLI PER IL TRATTAMENTO ACQUE La gamma Bonfiglioli è articolata in una grande varietà di prodotti, a coprire le necessità sia

Dettagli

LA SOLUZIONE PER I VOSTRI PROBLEMI

LA SOLUZIONE PER I VOSTRI PROBLEMI Conservatori serie MULTIPLUS I MULTIPLUS sono impianti studiati e realizzati da ACF per soddisfare l esigenza di quegli operatori che desiderino effettuare sia il ciclo di abbattimento-surgelazione sia

Dettagli

SUNNY MINI CENTRAL. Realizzare e progettare impianti fotovoltaici eccellenti

SUNNY MINI CENTRAL. Realizzare e progettare impianti fotovoltaici eccellenti SUNNY MINI CENTRAL Realizzare e progettare impianti fotovoltaici eccellenti Precisione Progettazione mirata dell impianto FV Progettare e realizzare sistemi FV eccellenti di medie e grandi dimensioni non

Dettagli

SolarMax serie HT La soluzione perfetta per impianti fotovoltaici commerciali e industriali

SolarMax serie HT La soluzione perfetta per impianti fotovoltaici commerciali e industriali SolarMax serie HT La soluzione perfetta per impianti fotovoltaici commerciali e industriali Massima redditività Gli impianti fotovoltaici sui tetti delle aziende commerciali e industriali hanno un enorme

Dettagli

w w w. a r o s - s o l a r. c o m

w w w. a r o s - s o l a r. c o m Inverter SIRIO EVO da 1500W a 12500W w w w. a r o s - s o l a r. c o m Sirio EVO Criteri di allacciamento alla rete elettrica Tutta la gamma è configurabile secondo le seguenti normative: - CEI 0-21 -

Dettagli

Ra.Store. L energia del sole anche di notte...

Ra.Store. L energia del sole anche di notte... GARZI A T Ra.Store. L energia del sole anche di notte... L impianto fotovoltaico è sicuramente uno dei modi più efficaci per autoprodurre energia. Sfortunatamente gran parte dell energia prodotta non

Dettagli

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni

Riduttori epicicloidali a gioco ridotto ad altissime prestazioni Riduttori epicicloidali a gioco ridotto ad altissime prestazioni BONFIGLIOLI SOLUTIONS 2 RIDUTTORI EPICICLOIDALI AD ALTISSIMA PRECISIONE 3 TENIAMO IL MONDO IN MOVIMENTO Nel suo sforzo di diventare un partner

Dettagli

Elettromobilità WITTENSTEIN La pole position degli azionamenti elettrici. efficiente compatto sicuro

Elettromobilità WITTENSTEIN La pole position degli azionamenti elettrici. efficiente compatto sicuro WITTENSTEIN La pole position degli azionamenti elettrici efficiente compatto sicuro 101 Azionamenti perfettamente integrati da un unico partner L elettromobilità va ben oltre il semplice funzionamento

Dettagli

Raddrizzatore - Caricabatteria. Applicazioni industriali: Caratteristiche principali:

Raddrizzatore - Caricabatteria. Applicazioni industriali: Caratteristiche principali: Batterie VRLA, vaso aperto, GEL o Ni/Cd con tensione di uscita da 24, 48, 110, 220 V CC sino a 30A Applicazioni industriali: Oil & Gas (Petrochemicals Offshore, Onshore, Tubazioni); Generazione e distribuzione

Dettagli

15/06/2011. I numeri di Santerno

15/06/2011. I numeri di Santerno 15/06/11 I numeri di Santerno Oltre anni nella progettazione e produzione di dispositivi per la conversione di potenza 26 anni negli inverter fotovoltaici e nelle tecnologie correlate Ad oggi, più di 1.5

Dettagli

REFERENCES SOLAR DRIVE

REFERENCES SOLAR DRIVE REFERENCES SOLAR DRIVE Solardrive L INVERTER SOLARE PER APPLICAZIONI DI POMPAGGIO Impieghi per potenze fino a 4 kwp Tale inverter utilizza il campo fotovoltaico per il pompaggio continuo di acqua durante

Dettagli

Soluzioni per applicazioni in campo minerario

Soluzioni per applicazioni in campo minerario Soluzioni per applicazioni in campo minerario 1 2 3 Soluzioni per applicazioni in campo minerario Con oltre 60 anni di esperienza nella progettazione, produzione e messa in funzione di riduttori, motoriduttori

Dettagli

Solutions in motion.

Solutions in motion. Solutions in motion. Solutions in motion. SIPRO SIPRO presente sul mercato da quasi trent anni si colloca quale leader italiano nella progettazione e produzione di soluzioni per il motion control. Porsi

Dettagli

ABL8RPS24050 Alimentatore con commutazione regolata - 1 o 2 fasi - 200..500 V CA - 24 V - 5 A

ABL8RPS24050 Alimentatore con commutazione regolata - 1 o 2 fasi - 200..500 V CA - 24 V - 5 A Scheda prodotto Caratteristiche ABL8RPS24050 Alimentatore con commutazione regolata - 1 o 2 fasi - 200..500 V CA - 24 V - 5 A Complementare Limiti tensione ingresso Frequenza di rete Corrente di spunto

Dettagli

E-Box Quadri di campo fotovoltaico

E-Box Quadri di campo fotovoltaico Cabur Solar Pagina 3 Quadri di campo fotovoltaico Quadri di stringa con elettronica integrata per monitoraggio e misura potenza/energia CABUR, sempre attenta alle nuove esigenze del mercato, ha sviluppato

Dettagli

CARICABATTERIE MODULARI HAWKER SEMPRE OPERATIVI! ANCHE CON UN MODULO IN MENO

CARICABATTERIE MODULARI HAWKER SEMPRE OPERATIVI! ANCHE CON UN MODULO IN MENO CARICABATTERIE MODULARI HAWKER SEMPRE OPERATIVI! ANCHE CON UN MODULO IN MENO MODULAR: DEFINISCE IL NUOVO STANDARD MASSIME PRESTAZIONI E AFFIDABILITÀ I moduli dei caricabatterie funzionano sul principio

Dettagli

Power at Work! High Power Motori con raffreddamento a liquido

Power at Work! High Power Motori con raffreddamento a liquido Power at Work! High Power Motori con raffreddamento a liquido randi vantaggi Dovendo trovare soluzioni pratiche ed innovative, l utilizzo di motori raffreddati a liquido consente una maggior libertà di

Dettagli

Smart Inverter WVC-600(Wireless) Descripiton

Smart Inverter WVC-600(Wireless) Descripiton Green Energy Smart Inverter Expert Smart Inverter Descripiton Ver:2018-I3 WVC-600(433MHz Wireless) Micro Inverter WVC-600 (Wireless) Using IP65 waterproof streamline design, Can effectively prevent rainwater

Dettagli

Sistemi per la continuità elettrica

Sistemi per la continuità elettrica Sistemi per la continuità elettrica INTRODUZIONE POLARIS Gruppi di continuità On-line Doppia Conversione Trifase 10K-180K La serie UPS POLARIS è del tipo online doppia conversione ad alta frequenza, con

Dettagli

Raddrizzatori di corrente e generatore di corrente pulsata serie PE

Raddrizzatori di corrente e generatore di corrente pulsata serie PE Dal 1970 Redic produce resistenze elettriche per uso industriale e civile. L esperienza maturata in questi anni, il continuo adeguamento alle esigenze del mercato, e la ricerca di sempre nuove soluzioni

Dettagli

Soluzioni per applicazioni con gru

Soluzioni per applicazioni con gru Soluzioni per applicazioni con gru 1 2 3 Soluzioni per applicazioni con gru Con oltre 60 anni di esperienza nelle soluzioni integrate per la trasmissione di potenza, Bonfiglioli offre una gamma completa

Dettagli

Ozone Systems MCP-XT Range

Ozone Systems MCP-XT Range Ozone Systems MCP-XT Range Ozone production from air, PSA, LOX between 40 g/h and 1,300 g/h Low power consumption especially with air Compact and completely housed Complete process instrumentation Air

Dettagli

ATA Energy Storage System

ATA Energy Storage System ATA Energy Storage System Inverter Off-Grid con accumulo L unico Inverter Off-Grid con accumulo intelligente e funzione UPS Con la fine degli incentivi statali, per la produzione di energia da fotovoltaico

Dettagli

Sistema di monitoraggio delle correnti in ingresso in impianti fotovoltaici

Sistema di monitoraggio delle correnti in ingresso in impianti fotovoltaici Sistema di monitoraggio delle correnti in ingresso in impianti fotovoltaici "L uso della piattaforma CompactRIO ha consentito l implementazione di un sistema di monitoraggio adatto ad essere utilizzato

Dettagli

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED) Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED) Alimentatori elettronici con tensione di uscita stabilizzata per moduli LED di segnalazione. Led driver with

Dettagli

Room 2005 Zhongshang Building No.100 HongKong Middle Road Qingdao China code 266071 tel 008653285891039 e-mail: fazio@cinaservizi.

Room 2005 Zhongshang Building No.100 HongKong Middle Road Qingdao China code 266071 tel 008653285891039 e-mail: fazio@cinaservizi. TURBINE EOLICHE 2012/2 Controllo della qualità Tutti i sistemi eolici, ad eccezione della torre, sono prodotti all interno della fabbrica che dispone all interno di tutti i settori meccanico, elettrico

Dettagli

Gli Inverter Sunways

Gli Inverter Sunways Gli Inverter Sunways Cenni Storici Agosto 1996: Agosto 2002: Marzo 2003: Maggio 2003: Giugno 2005: Ottobre 2005: Giugno 2007: Marzo 2008: introduzione sul mercato degli inverter solari senza trasformatore

Dettagli

Naturalmente Energia.

Naturalmente Energia. Naturalmente Energia. Produced by Gli aerogeneratori SWAN sono stati studiati e sviluppati principalmente per ottimizzare le caratteristiche ambientali del territorio Italiano, ponendo particolare attenzione

Dettagli

SPS. 10 kva - 200 kva

SPS. 10 kva - 200 kva SPS 10 kva - 200 kva HIGHLIGHTS Compatibile con sistemi On-grid e Off-grid Alimentazione di qualità ai carichi con integrazione di energia fotovoltaica Integrazione in impianti con inverter Aros Il Power

Dettagli

Energia come a casa in un unica soluzione

Energia come a casa in un unica soluzione GPX-5 Energia come a casa in un unica soluzione La rivoluzionaria soluzione ibrida Generatore, caricabatterie e inverter integrati Estremamente stabile, energia come a casa Dimensioni compatte = meno volume

Dettagli

Plant Logging & Monitoring

Plant Logging & Monitoring Plant Logging & Monitoring Solutions for solar energy Soluzioni per l energia solare 01101 00011 11101 01101 00101 11101 11101 01101 00101 11101 01101 00101 00011 11101 01101 00101 11101 01101 01101 00011

Dettagli

Power conversion system per fotovoltaico ed energy storage residenziale

Power conversion system per fotovoltaico ed energy storage residenziale Power conversion system per fotovoltaico ed energy storage residenziale Giordano Torri Nidec-ASI Fondazione Megalia. Convegno su L uso razionale dell energia negli edifici civili e nel terziario. Milano,

Dettagli

Perchè usare un parzializzatore di potenza residenziale?

Perchè usare un parzializzatore di potenza residenziale? Perchè usare un parzializzatore di potenza residenziale? Perchè posso accumulare l energia in eccesso prodotta dal mio impianto fotovoltaico come acqua calda nel boiler! Scenario con un interruttore meccanico

Dettagli

COMPRESSORI A VELOCITÀ VARIABILE. IVR da 40 a 240 HP

COMPRESSORI A VELOCITÀ VARIABILE. IVR da 40 a 240 HP COMPRESSORI A VELOCITÀ VARIABILE IVR da 0 a 20 HP I risparmio energetico IVR per l Ambiente Dalla pluriennale esperienza maturata nel mondo dell aria compressa abbiamo rilevato che, indipendentemente dalla

Dettagli

Caratteristiche tecniche. Alimentazione. Circuito di controllo. < 50 ms Tempo di ricaduta t R1

Caratteristiche tecniche. Alimentazione. Circuito di controllo. < 50 ms Tempo di ricaduta t R1 Modulo di sicurezza CS DM-01 Caratteristiche tecniche Custodia Custodia in poliammide PA 6.6, autoestinguente V0 secondo UL 94 Grado di protezione IP40 (custodia), IP20 (morsettiera) Dimensioni vedere

Dettagli

Sistemi di connessione Distribox e Spiderbox

Sistemi di connessione Distribox e Spiderbox Distribox and Spiderbox connectivity systems Very small and available in several variants to optimize use of available installation space. Robust design. Available working voltage: 12V, 24V, 110V or 240V;

Dettagli

THINKING DIGITAL SYNCHRONIZING WITH THE FUTURE PENSIERO DIGITALE: SINCRONIZZARSI COL FUTURO

THINKING DIGITAL SYNCHRONIZING WITH THE FUTURE PENSIERO DIGITALE: SINCRONIZZARSI COL FUTURO THINKING DIGITAL SYNCHRONIZING WITH THE FUTURE PENSIERO DIGITALE: SINCRONIZZARSI COL FUTURO A STEP FORWARD IN THE EVOLUTION Projecta Engineering developed in Sassuolo, in constant contact with the most

Dettagli

I moduli fotovoltaici saranno prodotti con celle in silicio policristallino ad alta efficenza, tolleranza di resa ± 4,5%, collegamento delle celle

I moduli fotovoltaici saranno prodotti con celle in silicio policristallino ad alta efficenza, tolleranza di resa ± 4,5%, collegamento delle celle RELAZIONE TECNICA La presente relazione tecnica ha per oggetto gli impianti solari fotovoltaici da realizzare presso i seguenti edifici di proprietà comunale: Scuola media P.D. Frattini potenza 20 kwp;

Dettagli

Componenti per impianti fotovoltaici

Componenti per impianti fotovoltaici Componenti per impianti fotovoltaici Inverter SunEzy Quadri stringa SunEzy Interruttori automatici in c.c. C60PV-DC Interruttore non automatico in c.c. C60NA-DC Interruttore non automatico in c.c. SW60-DC

Dettagli

SDS Surge Defence System

SDS Surge Defence System SDS Surge Defence System protezioni elettroniche innovative contro fulminazioni e sovratensioni per impianti fotovoltaici Engineering Costruzioni Elettromeccaniche P. Torresan http://www.torresansrl.it/

Dettagli