Interruttori magnetotermici e differenziali compatti DPC ed EPC

Dimensione: px
Iniziare la visualizzazioe della pagina:

Download "Interruttori magnetotermici e differenziali compatti DPC ed EPC"

Transcript

1 GE Industrial Solutions Interruttori magnetotermici e differenziali compatti DPC ed EPC Unibis*Ed. 02 Risparmiare fino al 50% di spazio nei quadri di distribuzione it.geindustrial.com

2 1 Gamma Interruttori magnetotermici differenziali compatti DPC 3 Vantaggi 6 Dati tecnici 7 Dimensioni 8 Interruttori magnetotermici differenziali compatti 2P in 2 moduli - Serie DPC45 10 Interruttori magnetotermici differenziali compatti 2P in 2 moduli - Serie DPC60 12 Interruttori magnetotermici differenziali compatti 2P in 2 moduli - Serie DPC Interruttori magnetotermici differenziali 3P+N in 4 moduli - Serie DMA63N Interruttori magnetotermici compatti EPC 16 Vantaggi 18 Dati tecnici 20 Interruttori magnetotermici compatti Serie EPC451N 21 Interruttori magnetotermici compatti Serie EPC61N 22 Interruttori magnetotermici compatti Serie EPC45 24 Interruttori magnetotermici compatti Serie EPC60 26 Interruttori magnetotermici compatti Serie EPC Caratteristiche tecniche 28 Sistemi sbarre 30 Ausiliari d interfaccia - Serie CA UN 31 Dimensioni 32 Indice numerico

3 Gamma interruttori magnetotermici differenziali compatti Unibis * DPC Pag. ipo Applicazione Poli Ausiliari Curva Corrente Nominale (A) 8 DPC45 2P si C ,5 10 DPC60 2P si B-C DPC100 2P si B-C DMA63 3P+N si B-C Potere d'interruzione (ka) Gamma interruttori magnetotermici compatti Unibis * EPC Pag. ipo Applicazione Poli Ausiliari Curva Corrente Nominale (A) 20 EPC451N 1+N si B-C , EPC61N 1+N si B-C EPC45 2 si B-C ,5 6 Potere d'interruzione (ka) Gamma 3, 4 si B-C , EPC60 2 si B-C , 4 si B-C EPC611 1P+1P (1 mod.) si B-C Domestico/piccolo terziario erziario Industria Uso navale B: 3-5 In C: 5-10 In EN EN EN

4 MD compatti 2 poli in 2 moduli La protezione completa e... Gli Unibis* MD sono l'ultima innovazione nella Linea Modulare Plus. Sono stati sviluppati per ridurre al minimo le dimensioni dei quadri di distribuzione. Le prestazioni sono state potenziate, raggiungendo i 10kA di potere d'interruzione e introducendo l'alta immunità. La protezione magnetotermica differenziale bipolare ora è disponibile in soli 2 moduli DIN! Novità Risparmiare fino al 50% di spazio nei quadri di distribuzione Capacità dei terminali fino a 35mm 2 cavo rigido fino a 25mm 2 cavo flessibile 2

5 ... la soluzione ai problemi di spazio Approvazioni navali 4500A 6-40A AC, A mA 6000A 6-40A AC, A, Ai mA 10000A 6-40A AC, A, Ai mA Compattezza: MD 2P in 2 moduli Gamma completa: 4,5 ka - 6 ka - 10 ka Da 6 a 40A, curva B e C Classi: AC - A - A immunizzata Compatibile al 100% con gli accessori Linea Modulare Plus Approvazioni: CEBEC, KEMA, NF, IMQ Certificati RINA e Lloyd's Register 4,5 ka 6 ka 10 ka 3

6 La gamma più completa per la protezione magnetotermica differenziale bipolare Novità Risparmiare fino al 50% di spazio nei quadri di distribuzione Morsetti sicuri Protezione in plastica con morsetti IP20 Indicatore di intervento differenziale Sostituzione rapida La doppia clip rende facile la rimozione dell'apparecchio Cablaggio rapido Barrette di connessione a puntale o forcelle, inseribili sopra o sotto Per applicazioni residenziali, commerciali e industriali Anche in versione tipo Ai (tipo A ad alta immunità) Leva con indicazione verde e rossa con attitudine al sezionamento 4

7 Qualità e affidabilità garantite nei quadri di distribuzione Unibis* Facile utilizzo utte le viti sono allo stesso livello per una rapida installazione. Allineati con i dispositivi Linea Modulare Plus e Unibis. Elevata coppia di serraggio Fino a 4Nm Parte della famiglia Novità I magnetotermici differenziali compatti sono perfettamente allineati agli interruttori Unibis Applicazioni navali Completamento della gamma Linea Modulare Plus e certificati dai principali registri navali. 2P MD 2P magnetotermico 3P magnetotermico 4P magnetotermico Piena funzionalità Un piccolo contatto ausiliario (1/2 modulo) funge da interfaccia con tutti gli accessori. Montabile su entrambi i lati. 5

8 Caratteristiche tecniche MD - Interruttori magnetotermici differenziali compatti Serie DPC45 DPC60 DPC100 DMA63N MD compatti Norme di riferimento EN EN EN EN Curve di intervento magnetotermico C B,C B,C B,C Classe di intervento differenziale AC, A AC, A, Ai AC, A, Ai A empo di intervento istantaneo a IΔn ms <60 <60 <60 - Corrente nominale In A Corrente differenziale nominale IΔn ma 30, , 30, , 30,300 30, 300 Indicatore di intervento differenziale: blu sì sì sì sì emperatura di calibrazione C Numero di poli (numero moduli) 2P (2 mod.) 2P (2 mod.) 2P (2 mod.) 3P+N (4 mod.) ensione nominale Un AC V Frequenza (Hz) Hz (3) 50 (3) 50/60 Massima tensione di esercizio Ub max V Minima tensione di esercizio Ub min V 117 (2) 117 (2) 117 (2) 170 ensione minima per la protezione differenziale V Indipendente dalla tensione Indipendente dalla tensione Indipendente dalla tensione Indipendente dalla tensione Lato di alimentazione alto/basso alto/basso alto/basso alto/basso Classe di limitazione dell'energia Potere di chiusura e d'interruzione A Potere di interruzione (Icn) A Distanza di sicurezza tra due dispositivi mm Adatto al sezionamento sì sì sì - Proprietà dielettriche ensione di isolamento V(DC) enuta impulso 1,2/50us kv Resistenza di isolamento Mohm Rigidità dielettrica V Resistenza all' urto in direzione x, y, z (EN/IEC 60077/16.3) 40 g, 18 urti 5 ms 40 g, 18 urti 5 ms 40 g, 18 urti 5 ms 40 g, 18 urti 5 ms Resistenza alle vibrazioni in direzione x, y, z (EN/IEC ) 1,5g, 30 min, 0 80Hz 1,5g, 30 min, 0 80Hz 1,5g, 30 min, 0 80Hz 5g, 30 min, 0 80Hz N massimo di manovre Elettriche a Un, In Meccaniche Grado di protezione sui morsetti/ in quadro o centralino IP20/IP40 IP20/IP40 IP20/IP40 IP20/IP40 Grado di autoestinguenza (in accordo a UL 94) V2 V2 V2 V2 ropicalizzazione (EN/IEC , DIN 40046) C/RH 55ºC/95% 55ºC/95% 55ºC/95% 55ºC/95% Grado di inquinamento (EN/IEC ) emperatura di impiego ºC da -5 a +60 da -5 a +60 da -5 a +60 da -5 a +60 (da -25 ipo A) (da -25 ipo A, Ai) (da-25 ipo A, Ai) emperatura di stoccaggio ºC da -25 a +70 da -25 a +70 da -25 a +70 da -25 a +40 Capacità dei terminali Cavo rigido min/max (alto) mm² 1/35 1/35 1/35 1/25 Cavo flessibile min/max (alto) mm² 1/25 1/25 1/25 1/25 Cavo rigido min/max (basso) mm² 1/35 1/35 1/35 1/35 Cavo flessibile min/max (basso) mm² 1/25 1/25 1/25 1/35 Coppia (Nm) Nm Accessori affiancabili Contatti ausiliari sì sì sì sì ele U, ele L, ele MP, PBS sì (1) sì (1) sì (1) 1 x CA Numero massimo di accessori affiancabili (per lato) 4x CA + 1x elel + 1x ele U 4x CA + 1x elel + 1x ele U 4x CA + 1x elel + 1x ele U no Riarmo automatico elerec 2 sì (DPC100) sì (DPC100) sì no Cablaggio rapido Pettine (alto/basso) sì/sì sì/sì sì/sì sì/sì Forcelle (alto/basso) sì/sì sì/sì sì/sì sì/sì Larghezza per modulo mm Peso per modulo gr Confezione/imballo pcs 1/6 1/6 1/6 1/3 Approvazioni IMQ NF, CEBEC, KEMA, NF, CEBEC, KEMA, IMQ, VDE IMQ, VDE, LR, RINA IMQ Marchio CE sì sì sì sì (1) Richiede contatto ausiliario CA come interfaccia, (2) U b min = 150V per 30mA, (3) 50/60 Hz per tipo Ai 6

9 Potere di interruzione MD - Interruttori magnetotermici differenziali compatti Serie DPC45 DPC60 DPC100 DMA63N Potere di interruzione nominale (Icn) a 230Vac (EN/IEC ) A Potere di interruzione nominale di servizio (Ics) ka 4,5 6 7,5 6 Potere di interruzione nominale estremo (Icu) (EN/IEC ) ka Panoramica della gamma Pagina Serie Corr. differ. nom. (ma) Poli ipo Curva Potere magnetotruz di inter DPC AC C 4500 x x AC C 4500 x x A C 4500 x x A C 4500 x x DPC AC C 6000 x x AC C 6000 x x AC C 6000 x x A B 6000 x x 230 C 6000 x x A B 6000 x x 230 C 6000 x x A B 6000 x x 230 C 6000 x x Ai B 6000 x x 230 C 6000 x x Ai B 6000 x x 230 C 6000 x x 230 Sezionamento Accessori ensione nominale Caratteristiche tecniche 13 DPC AC C x x AC C x x AC C x x A B x x 230 C x x A B x x 230 C x x A B x x 230 C x x Ai B x x 230 C x x Ai B x x 230 C x x DMA63N 30 3+N A C 6000 x x N A B 6000 x x 400 Dimensioni Serie DPC45 / DPC60 / DPC /2 3/4 36 2/1 4/3 7

10 0-OFF 0-OFF Unibis* Interruttori magnetotermici differenziali compatti 2P in 2 moduli Serie DPC45 EN /IEC ,5kA ipo AC ipo A Novità MD compatti Applicazioni Approvazioni / Marchi Accessori ele U ele L CA CA UN 2P RCBOs L'accoppiamento degli accessori richiede un contatto ausiliario CA UN come interfaccia. Solo il comando motore ele MP non richiede un CA UN. Contatti ausiliari Caratteristiche tecniche Dimensioni CA UN CA ele L ele U 2 x CA ELE MP ELE MP 2 x CA Pagina 31 Pagina 6 Pagina 7 Prestazioni Corrente nominale In (A) 6-40 Corrente differenziale nominale (ma) 30, 300 Caratt. di intervento magnetotermico C ensione nominale in AC Un (V) 230 ensione minima di impiego Ub min (V) 117 (1) No manovre meccaniche/elettriche 10000/20000 ropicalizzazione sec. EN ºC/95% Cap. morsetti cavo flessibile/rigido (mm²) 25/35 Poli 2 Resistenza agli scatti intempestivi (A) 250 Variazione della temperatura ambiente (ºC) ipo AC: -5 fino a 60 ipo A: -25 fino a 60 Peso per modulo (g) 110 Potere di interruzione Secondo EN Potere di chiusura e d'interruzione diff. nom. I m = 4500A Classe di limitazione dell'energia 3 Potere d'interruzione nominale estremo Icn = 4500A fino a 230V (1) Ubmin = 150V per 30mA 8

11 MD compatto Serie DPC45 - ipo AC - curva C 10mA 30 ma 300 ma In (A) ipo N. rif. ipo N. rif. ipo N. rif. Conf./ imballo 2P DPC45C06/ DPC45C06/ / DPC45C10/ DPC45C10/ / DPC45C13/ DPC45C13/ / DPC45C16/ DPC45C16/ / DPC45C20/ DPC45C20/ / DPC45C25/ DPC45C25/ / DPC45C32/ DPC45C32/ / DPC45C40/ DPC45C40/ /6 E S 1/2 3/4 2/1 4/3 Serie DPC45 - ipo A - curva C 2P DPCA45C06/ DPCA45C06/ / DPCA45C10/ DPCA45C10/ / DPCA45C13/ DPCA45C13/ / DPCA45C16/ DPCA45C16/ / DPCA45C20/ DPCA45C20/ / DPCA45C25/ DPCA45C25/ / DPCA45C32/ DPCA45C32/ / DPCA46C40/ DPCA45C40/ /6 Serie DPC45 E S 1/2 3/4 2/1 4/3 Novità 9

12 0-OFF 0-OFF Unibis* Interruttori magnetotermici differenziali compatti 2P in 2 moduli Serie DPC60 EN /IEC kA ipo AC ipo A - Ai Novità MD compatti Applicazioni Approvazioni / Marchi Accessori ele U ele L CA CA UN 2P RCBOs CA UN 2 x CA ELE MP ELE MP 2 x CA L'accoppiamento degli accessori richiede un contatto ausiliario CA UN come interfaccia. Solo il comando motore ele MP non richiede un CA UN. Contatti ausiliari Caratteristiche tecniche Dimensioni CA ele L ele U Pagina 31 Pagina 6 Pagina 7 Prestazioni Corrente nominale In (A) 6-40 Corrente differenziale nominale (ma) 10, 30, 300 Caratt. di intervento magnetotermico B, C ensione nominale in AC Un (V) 230 ensione minima di impiego Ub min (V) 117 (1) No manovre meccaniche/elettriche 10000/20000 ropicalizzazione sec. EN ºC/95% Cap. morsetti cavo flessibile/rigido (mm²) 25/35 Poli 2 Resistenza agli scatti intempestivi (A) 250 (A, AC), 3000 (Ai) Variazione della temperatura ambiente (ºC) ipo AC: -5 fino a 60 ipo A: -25 fino a 60 Peso per modulo (g) 110 Potere di interruzione Secondo EN Potere di chiusura e d'interruzione diff. nom. I m = 6000A Classe di limitazione dell'energia 3 Potere d'interruzione nominale estremo Icn = 6000A fino a 230V (1) Ubmin = 150V per 30mA 10

13 MD compatto Serie DPC60 - ipo AC - curva C 10mA 30 ma 300 ma In (A) ipo N. rif. ipo N. rif. ipo N. rif. Conf./ imballo 2P DPC60C06/ DPC60C06/ /6 10 DPC60C10/ DPC60C10/ DPC60C10/ / DPC60C13/ DPC60C13/ /6 16 DPC60C16/ DPC60C16/ DPC60C16/ / DPC60C20/ DPC60C20/ / DPC60C25/ DPC60C25/ / DPC60C32/ DPC60C32/ / DPC60C40/ DPC60C40/ /6 1/2 3/4 E S E S 2/1 4/3 1/2 3/4 Serie DPC60 - ipo A - curva B 2P DPCA60B06/ DPCA60B06/ / DPCA60B10/ DPCA60B10/ / DPCA60B13/ DPCA60B13/ / DPCA60B16/ DPCA60B16/ / DPCA60B20/ DPCA60B20/ / DPCA60B25/ DPCA60B25/ / DPCA60B32/ DPCA60B32/ / DPCA60B40/ DPCA60B40/ /6 Serie DPC60 2/1 4/3 Serie DPC60 - ipo A - curva C E S 1/2 3/4 2P DPCA60C06/ DPCA60C06/ /6 10 DPCA60C10/ DPCA60C10/ DPCA60C10/ / DPCA60C13/ DPCA60C13/ /6 16 DPCA60C16/ DPCA60C16/ DPCA60C16/ / DPCA60C20/ DPCA60C20/ / DPCA60C25/ DPCA60C25/ / DPCA60C32/ DPCA60C32/ / DPCA60C40/ DPCA60C40/ /6 2/1 4/3 Serie DPC60 - ipo Ai (alta immunitá) - curva C 2P DPCAi60C06/ DPCAi60C06/ / DPCAi60C10/ DPCAi60C10/ / DPCAi60C13/ DPCAi60C13/ / DPCAi60C16/ DPCAi60C16/ / DPCAi60C20/ DPCAi60C20/ / DPCAi60C25/ DPCAi60C25/ / DPCAi60C32/ DPCAi60C32/ / DPCAi60C40/ DPCAi60C40/ /6 1/2 3/4 E S 2/1 4/3 Novità 11

14 0-OFF 0-OFF Unibis* Interruttori magnetotermici differenziali compatti 2P in 2 moduli Serie DPC100 EN /IEC kA ipo AC ipo A - Ai Novità MD compatti Applicazioni Approvazioni / Marchi Accessori ele U ele L CA CA UN 2P RCBOs CA UN 2 x CA ELE MP ELE MP 2 x CA L'accoppiamento degli accessori richiede un contatto ausiliario CA UN come interfaccia. Solo il comando motore ele MP non richiede un CA UN. Contatti ausiliari Caratteristiche tecniche Dimensioni CA ele L ele U Pagina 31 Pagina 6 Pagina 7 Prestazioni Corrente nominale In (A) 6-40 Corrente differenziale nominale (ma) 10, 30, 300 Caratt. di intervento magnetotermico B-C ensione nominale in AC Un (V) 230 ensione minima di impiego Ub min (V) 117 (1) No manovre meccaniche/elettriche 10000/20000 ropicalizzazione sec. EN ºC/95% Cap. morsetti cavo flessibile/rigido (mm²) 25/35 Poli 2 Resistenza agli scatti intempestivi (A) 250 (A, AC), 3000 (Ai) Variazione della temperatura ambiente (ºC) ipo AC: -5 fino a 60 ipo A: -25 fino a 60 Peso per modulo (g) 110 (1) Ubmin = 150V per 30mA Potere di interruzione Potere di chiusura e d'interruzione diff. nom. IΔm = 3000A acc. to EN IΔm = 1500A acc. to IEC Classe di limitazione dell'energia 3 Potere d'interruzione nominale estremo Icn = 10000A fino a 230V 12

15 MD compatto Serie DPC100 - ipo AC - curva C 10mA 30 ma 300 ma In (A) ipo N. rif. ipo N. rif. ipo N. rif. Conf./ imballo 2P DPC100C06/ DPC100C06/ /6 10 DPC100C10/ DPC100C10/ DPC100C10/ / DPC100C13/ DPC100C13/ /6 16 DPC100C16/ DPC100C16/ DPC100C16/ / DPC100C20/ DPC100C20/ / DPC100C25/ DPC100C25/ / DPC100C32/ DPC100C32/ / DPC100C40/ DPC100C40/ /6 1/2 3/4 E S E S 2/1 4/3 1/2 3/4 2/1 4/3 Serie DPC100 - ipo A - curva B 2P DPCA100B06/ DPCA100B06/ /6 10 DPCA100B10/ DPCA100B10/ DPCA100B10/ /6 13 DPCA100B13/ DPCA100B13/ DPCA100B13/ /6 16 DPCA100B16/ DPCA100B16/ DPCA100B16/ / DPCA100B20/ DPCA100B20/ / DPCA100B25/ DPCA100B25/ / DPCA100B32/ DPCA100B32/ / DPCA100B40/ DPCA100B40/ /6 Serie DPC100 Serie DPC100 - ipo A - curva C E S 1/2 3/4 2/1 4/3 2P DPCA100C06/ DPCA100C06/ /6 10 DPCA100C10/ DPCA100C10/ DPCA100C10/ /6 13 DPCA100C13/ DPCA100C13/ DPCA100C13/ /6 16 DPCA100C16/ DPCA100C16/ DPCA100C16/ / DPCA100C20/ DPCA100C20/ / DPCA100C25/ DPCA100C25/ / DPCA100C32/ DPCA100C32/ / DPCA100C40/ DPCA100C40/ /6 Serie DPC100 - ipo Ai (alta immunitá) - curva B E S 1/2 3/4 2P DPCAi100B06/ DPCAi100B06/ / DPCAi100B10/ DPCAi100B10/ / DPCAi100B13/ DPCAi100B13/ / DPCAi100B16/ DPCAi100B16/ / DPCAi100B20/ DPCAi100B20/ / DPCAi100B25/ DPCAi100B25/ / DPCAi100B32/ DPCAi100B32/ / DPCAi100B40/ DPCAi100B40/ /6 2/1 4/3 Serie DPC100 - ipo Ai (alta immunitá) - curva C E S 1/2 3/4 2P DPCAi100C06/ DPCAi100C06/ / DPCAi100C10/ DPCAi100C10/ / DPCAi100C13/ DPCAi100C13/ / DPCAi100C16/ DPCAi100C16/ / DPCAi100C20/ DPCAi100C20/ / DPCAi100C25/ DPCAi100C25/ / DPCAi100C32/ DPCAi100C32/ / DPCAi100C40/ DPCAi100C40/ /6 2/1 4/3 Novità 13

16 3P+N, 3P RCBOs - Interruttori magnetotermici differenziali Serie DMA63N ipo A EN Novità MD compatti Accessori Ausiliario Max 1 contatto aux CAH DMA63N sul lato sinistro Cablaggio Prestazioni Corrente nominale In (A) Corrente differenziale nominale (ma) 30, 300 Caratt. di intervento magnetotermico C, B ensione nominale Un (V) 400 ensione minima di impiego Ub min (V) 290 No manovre meccaniche/elettriche 10000/20000 ropicalizzazione secondo 55ºC/95% IEC /2-30 en DIN Cap. terminale cavo flessibile/rigido (mm²) 25/35 Poli (moduli) 3P+N Resistenza contro gli scatti intempestivi (A) 250A 8/20µs Variazione della temperatura ambiente (ºC) -25 up to +40 Peso totale (g) 120 Potere di interruzione Secondo EN/IEC Potere di chiusura e d'interruzione diff. nom. I m=3000a Potere d'interruzione nominale estremo Icn = 6000 A fino a 230V Classe di limitazione dell'energia 3 Dimensioni 14

17 Series DMA63N ipo A - curva C - 3P+N 30 ma 300 ma Conf./ In (A) ipo N. rif. ipo N. rif. imballo 10 DMA63NC10/ DMA63NC10/ DMA63NC13/ DMA63NC13/ DMA63NC16/ DMA63NC16/ DMA63NC20/ DMA63NC20/ DMA63NC25/ DMA63NC25/ DMA63NC32/ DMA63NC32/ ipo A - curva B - 3P+N 30 ma 300 ma Conf./ In (A) ipo N. rif. ipo N. rif. imballo 10 DMA63NB10/ DMA63NB10/ DMA63NB13/ DMA63NB13/ DMA63NB16/ DMA63NB16/ DMA63NB20/ DMA63NB20/ DMA63NB25/ DMA63NB25/ DMA63NB32/ DMA63NB32/ Serie DMA63N Series CAH DMA63N Ausiliario Conf./ Funzione ipo di contatto ipo N. rif. imballo H 1NO + 1NC CAH DMA63N Contatto aux sul lato sinistro. Novità 15

18 2 poli in 1 mod Interruttori magnetotermici Unibis*: la soluzione ai probl Gli apparecchi modulari Unibis* sono tra gli ultimi prodotti inseriti nella gamma modulare GE e sono sviluppati con lo scopo di ridurre al minimo le dimensioni dei quadri di distribuzione, aumentando le prestazioni fino a 10kA. erminali sicuri Fino alla combinazione di conduttori 6mm 2 + 4mm 2. Coppia di serraggio Nm t 16

19 ulo emi di spazio 1P+1P in 1 modulo 1P+N in 1 modulo 2P in 1 modulo 3P in 2 modulo 4P in 2 modulo 3 livelli di prestazioni fino a 10kA Design compatto 2P in 1 modulo, 3 e 4P in 2 moduli Gamma completa: da 4,5-6-10kA (1), 2-40A, curva B e C 100% di compatibilità con la gamma di accessori ed ausiliari Linea Modulare Plus 100% Qualità ed affidabilità IMQ, VDE, KEMA, NF, RINA, Lloyd s register 4,5kA 6kA 10kA (1) 10kA per 1P+N e 2P

20 Caratteristiche tecniche - Interruttori magnetotermici compatti EPC Serie EPC451N EPC61N Interruttori magnetotermici Norme di riferimento EN EN Curve B,C B,C Corrente nominale In (A) emperatura di calibrazione ( C) Numero di poli (numero moduli) 1+N (1 mod.) 1+N (1 mod.) Neutro protetto - - ensione nominale Un AC 1P+N (V) P+1P (V) - - 2P (V) - - 3P (V) - 4P (V) - ensione nominale Un DC 2P (V ) - - Frequenza (Hz) 50/60 50/60 a DC sganc. magn. + 40% sganc. magn. + 40% a 400 Hz sganc. magn. + 50% sganc. magn. + 50% Massima tensione di esercizio Ub max (V) Minima tensione di esercizio Ub min (V) Classe di limitazione (EN 60898) (EN ) 3 3 ensione nominale Grado di inquinamento 2 (V) Grado di inquinamento 3 (V) enuta impulso (kv) 6 6 Resistenza di isolamento (MΩ) Rigidità dielettrica (kv) 2,5 2,5 Resistenza alle vibrazioni (direzioni x,y,z) (IEC 77/16.3) (g) 3 3 Durata Elettrica a Un,In (1) (1) Meccanica Categoria di utilizzazione (EN ) A A Posizione di montaggio orizzontale/verticalmente qualsiasi qualsiasi Ingresso dall alto e dal basso si si Grado di protezione (contenitore esterno/interno con porta) IP20/IP40 IP20/IP40 Grado di autoestinguenza (in accordo a UL 94) V2 V2 ropicalizzazione (in acc. a EN /DIN 40046) +55 C/95%U.R. +55 C/95%U.R. emperatura di funzionamento ( C) -25/+55-25/+55 emperatura di immagazzinamento ( C) -55/+55-55/+55 Capacità dei terminali Cavo rigido min/max (alto) (mm 2 ) 1/16 (2) 1/16 (2) Cavo flessibile min/max (alto) (mm 2 ) 1/10 (2) 1/10 (2) Cavo rigido min/max (basso) (mm 2 ) 1/16 (2) 1/16 (2) Cavo flessibile min/max (basso) (mm 2 ) 1/10 (2) 1/10 (2) Coppia (Nm) 3 3 Dispositivi affiancabili Contatti ausiliari si serie CA UN si serie CA UN ele U si (3) si (3) ele L si (3) si (3) ele MP si si PBS si (3) si (3) Sistema sbarre Pin (alto/basso) si/si si/si Perk (alto/basso) no/no no/no Accessori si si Profondità (mm) Peso (gr) Imballaggio Approvazioni IMQ, KEMA IMQ, KEMA CE-Marchio si si Pagina Potere di interruzione Serie EPC451N EPC61N Potere di interruzione AC (ka) (ka) EN/IEC P+N 230 V 4,5 6 1P+1P 230 V - - 2P 400 V - - 3P 400 V - - 4P 400 V - - EN Ics 1P+N 230 V 6 10 (servizio) 1P+1P 230 V - - 2P 230V - - 2P 415 V - - 3P 415 V - - 4P 415 V - - Potere di interruzione DC EN/IEC lcu 2P 96 V (1) 8000 per 32 e 40 A (2) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) (3) Richiede un contatto ausiliario CA UN come interfaccia

21 EPC45 EPC60 EPC611 EN EN EN B,C B,C B,C (4) (1 mod.), 3e4 (2 mod.) 2 (1 mod.), 3e4 (2 mod.) 1P+1P (1 mod.) /60 50/60 50/60 sganc. magn. + 40% sganc. magn. + 40% sganc. magn. + 40% sganc. magn. + 50% sganc. magn. + 50% sganc. magn. + 50% 250/ / / ,5 2,5 2, (1) (1) A A A qualsiasi qualsiasi qualsiasi si si si IP20/IP40 IP20/IP40 IP20/IP40 V2 V2 V2 +55 C/95%U.R. +55 C/95%U.R. +55 C/95%U.R. -25/+55-25/+55-25/+55-55/+55-55/+55-55/+55 1/16 (2) 1/16 (2) 1/16 (2) 1/10 (2) 1/10 (2) 1/10 (2) 1/16 (2) 1/16 (2) 1/16 (2) 1/10 (2) 1/10 (2) 1/10 (2) si serie CA UN si serie CA UN si serie CA UN si (3) si (3) si (3) si (3) si (3) si (3) si si si si (3) si (3) si (3) si/si si/si si/si no/no no/no no/no si si si 18/36 18/ / / /6 12/6 12/6 IMQ, NF IMQ, NF, RINA IMQ, VDE, RINA si si si Dati tecnici EPC45 EPC60 EPC611 (ka) (ka) (ka) ,5 10-4,5 6-4, ,5 6 - (1) 8000 per 32 e 40 A (4) 32A, 3P e 4P (2) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) (3) Richiede un contatto ausiliario CA UN come interfaccia 19

22 Interruttori magnetotermici compatti 1P+N Interruttori magnetotermici Applicazioni Serie EPC451N Prestazioni EN/IEC EN/IEC kA Approvazioni / Marchi Dispositivi aggiuntivi Ausiliari CA UN ele L ele U PBS ele MP L accoppiamento di dispositivi aggiuntivi (ele L, ele U, PBS) all interruttore prevede l utilizzo di un contatto ausiliario CA UN di interfaccia. (L'accoppiamento con ele MP non richiede ausiliari CA UN) Corrente nominale (In) (A) 6-40 ensione nominale AC (Un) (V) 230 ensione minima di impiego UBmin (V) 12 Caratteristica di intervento B-C Classe di limitazione (EN 60898) 3 No massimo di manovre meccaniche/ elettriche 20000/10000 (1) ropicalizzazione (EN/IEC ) 95% di UR a 55 C Capacità dei terminali (cavo flessibile/rigido) (mm²) (2) Poli 1P+N (1 mod.) Peso (g) 125 Potere di interruzione AC secondo EN/IEC Poli V Icn/Ics (ka) 1P+N 230 4,5 AC secondo EN/IEC Poli V Icu (ka) 1P+N Attenzione: non usare in sistemi I Serie EPC451N - 4,5kA curva B-C B C In (A) ipo N. rif. ipo N. rif. Q. tà imb. 1P + N 6 EPC 451N B EPC 451N C mod. 10 EPC 451N B EPC 451N C EPC 451N B EPC 451N C EPC 451N B EPC 451N C EPC 451N B EPC 451N C EPC 451N B EPC 451N C EPC 451N B EPC 451N C Contatti ausiliari Caratteristiche tecniche Sbarre Dimensioni Pagina 31 Pagina 18 Pagina 28 Pagina 31 (1) 8000 per 32 e 40A (2) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) 20

23 Interruttori magnetotermici compatti 1P+N Serie EPC61N EN/IEC EN/IEC kA Applicazioni Approvazioni / Marchi Dispositivi aggiuntivi Prestazioni Corrente nominale (In) (A) 2-40 ensione nominale AC (Un) (V) 230 ensione minima di impiego UBmin (V) 12 Caratteristica di intervento B-C Classe di limitazione (EN 60898) 3 No massimo di manovre meccaniche/elettriche 20000/10000 (1) ropicalizzazione (EN/IEC ) 95% di UR a 55 C Capacità dei terminali (cavo flessibile/rigido) (mm²) (2) Poli 1P+N (1 mod.) Peso (g) 125 Serie EPC61N Ausiliari CA UN ele L ele U PBS ele MP L accoppiamento di dispositivi aggiuntivi (ele L, ele U, PBS) all interruttore prevede l utilizzo di un contatto ausiliario CA UN di interfaccia. (L'accoppiamento con ele MP non richiede ausiliari CA UN) Contatti ausiliari Caratteristiche tecniche Sbarre Dimensioni Pagina 31 Pagina 18 Pagina 28 Pagina 31 Potere di interruzione AC secondo EN/IEC Poli V Icn/Ics (ka) 1P+N AC secondo EN/IEC Poli V Icu (ka) 1P+N Attenzione: non utilizzare in sistemi I Serie EPC61N - 6kA - curva B-C B C In (A) ipo N. rif. ipo N. rif. Q. tà imb. 1P + N 2 EPC 61N B EPC 61N C mod. 4 EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C EPC 61N B EPC 61N C (1) 8000 per 32 e 40A (2) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) 21

24 Interruttori magnetotermici compatti P Interruttori magnetotermici Applicazioni Serie EPC45 Prestazioni EN/IEC EN/IEC kA Approvazioni / Marchi Dispositivi aggiuntivi Ausiliari CA UN ele L ele U PBS ele MP L accoppiamento di dispositivi aggiuntivi (ele L, ele U, PBS) all interruttore prevede l utilizzo di un contatto ausiliario CA UN di interfaccia. (L'accoppiamento con ele MP non richiede ausiliari CA UN) Corrente nominale (In) (A) 6-40 (1) ensione nominale AC (Un) (V) 230/400 ensione minima di impiego UBmin (V) 12 Caratteristica di intervento B-C Classe di limitazione (EN 60898) 3 No massimo di manovre meccaniche/elettriche 20000/10000 (2) ropicalizzazione (EN/IEC ) 95% di UR a 55 C Capacità dei terminali (cavo flessibile/rigido) (mm²) (3) Poli 2, 3, 4 Peso (g/mod.) 160 Potere di interruzione AC secondo EN/IEC Poli V Icn/Ics (ka) 2P 400 4,5 3P 400 4,5 4P 400 4,5 AC secondo EN/IEC Poli V Icu (ka) 2P P P DC secondo EN/IEC Poli Un (V ) Icu (ka) 2P 96 4,5 (1) 32A, 3P e 4P (2) 8000 per 32/40A (3) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) Contatti ausiliari Caratteristiche tecniche Sbarre Dimensioni Pagina 31 Pagina 18 Pagina 28 Pagina 31 22

25 Serie EPC45-4,5kA - curva B-C B In (A) ipo N. rif. ipo N. rif. 2P 6 EPC 452 B EPC 452 C mod. 10 EPC 452 B EPC 452 C EPC 452 B EPC 452 C EPC 452 B EPC 452 C EPC 452 B EPC 452 C EPC 452 B EPC 452 C EPC 452 B EPC 452 C C Q. tà imb. 3P (1) 6 EPC 453 B (1) EPC 453 C (1) 6 2 mod. 10 EPC 453 B (1) EPC 453 C (1) 6 16 EPC 453 B (1) EPC 453 C (1) 6 20 EPC 453 B (1) EPC 453 C (1) 6 25 EPC 453 B (1) EPC 453 C (1) 6 32 EPC 453 B (1) EPC 453 C (1) 6 Serie EPC45 4P 6 EPC 454 B EPC 454 C mod. 10 EPC 454 B EPC 454 C EPC 454 B EPC 454 C EPC 454 B EPC 454 C EPC 454 B EPC 454 C EPC 454 B EPC 454 C (1) Il Contatto ausiliario CA UN deve essere collocato sul lato sinistro del magnetotermico tripolare 23

26 Interruttori magnetotermici compatti P Interruttori magnetotermici Applicazioni Serie EPC60 Prestazioni EN/IEC EN/IEC kA (2) (1) Approvazioni / Marchi Dispositivi aggiuntivi Auxiliaries CA UN ele L ele U PBS ele MP L accoppiamento di dispositivi aggiuntivi (ele L, ele U, PBS) all interruttore prevede l utilizzo di un contatto ausiliario CA UN di interfaccia. (L'accoppiamento con ele MP non richiede ausiliari CA UN) Corrente nominale (In) (A) 2-40 (3) ensione nominale CA (Un) (V) 230/400 ensione minima di impiego UBmin (V) 12 Caratteristica di intervento B-C Classe di limitazione (EN 60898) 3 No massimo di manovre meccaniche/elettriche 20000/10000 (4) ropicalizzazione (EN/IEC ) 95% di UR a 55 C Capacità dei terminali (cavo flessibile/rigido) (mm²) (5) Poli 2, 3, 4 Peso (g/mod) 160 Potere di interruzione Secondo EN/IEC Poli V Icn/Ics (ka) 2P P P Secondo EN/IEC Poli V Icu (ka) 2P P P CC secondo EN/IEC Poli Un (V ) Icu (ka) 2P P (1) 10000A per 2P a 230Vac (2) 6kA a 415V (3) 32A, 3P & 4P (4) 8000 per 32/40A (5) Accettati anche (2 x 4mm²) o (1 x 4mm²)+(1 x 6mm²) Contatti ausiliari Caratteristiche tecniche Sbarre Dimensioni Pagina 31 Pagina 18 Pagina 28 Pagina 31 24

27 Serie EPC60-6kA - curve B-C B In (A) ipo N. rif. ipo N. rif. 2P 2 EPC 62 B EPC 62 C mod. 4 EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C EPC 62 B EPC 62 C C Q. tà imb. 3P (1) 2 EPC 63 B (1) EPC 63 C (1) 6 2 mod. 4 EPC 63 B (1) EPC 63 C (1) 6 6 EPC 63 B (1) EPC 63 C (1) 6 10 EPC 63 B (1) EPC 63 C (1) 6 16 EPC 63 B (1) EPC 63 C (1) 6 20 EPC 63 B (1) EPC 63 C (1) 6 25 EPC 63 B (1) EPC 63 C (1) 6 32 EPC 63 B (1) EPC 63 C (1) 6 Serie EPC60 4P 2 EPC 64 B EPC 64 C mod. 4 EPC 64 B EPC 64 C EPC 64 B EPC 64 C EPC 64 B EPC 64 C EPC 64 B EPC 64 C EPC 64 B EPC 64 C EPC 64 B EPC 64 C EPC 64 B EPC 64 C (1) Il contatto ausiliario CA UN deve essere collocato sul lato sinistro del magnetotermico tripolare Dimensioni Interruttori compatti - Serie EPC - Unibis* 25

28 Interruttori magnetotermici compatti 1P+1P Interruttori magnetotermici Applicazioni Serie EPC611 EN/IEC EN/IEC kA 2 interruttori 1P indipendenti in un solo modulo. Prestazioni Approvazioni / Marchi Dispositivi aggiuntivi Corrente nominale (In) (A) 2-20 ensione nominale AC (Un) (V) 230 ensione minima di impiego UBmin (V) 12 Caratteristica di intervento B-C Classe di limitazione (EN 60898) 3 No massimo di manovre meccaniche/elettriche 20000/10000 ropicalizzazione (EN/IEC ) 95% di UR a 55 C Capacità dei terminali (cavo flessibile/rigido) (mm²) (1) Poli 1P+1P (1 mod.) Peso (g) 125 Ausiliari CA UN ele L ele U PBS ele MP L accoppiamento di dispositivi aggiuntivi (ele L, ele U, PBS) all interruttore prevede l utilizzo di un contatto ausiliario CA UN di interfaccia. (L'accoppiamento con ele MP non richiede ausiliari CA UN) Potere di interruzione AC secondo EN/IEC Poli V Icn/Ics (ka) AC secondo EN/IEC Poli V Icu (ka) Attenzione: non utilizzare in sistemi I Serie EPC611-6kA - curva B-C B C In (A) ipo N. rif. ipo N. rif. Q. tà imb. 1P+1P 2 EPC 611 B EPC 611 C mod. 4 EPC 611 B EPC 611 C EPC 611 B EPC 611 C EPC 611 B EPC 611 C EPC 611 B EPC 611 C EPC 611 B EPC 611 C Contatti ausiliari Caratteristiche tecniche Sbarre Dimensioni Pagina 31 Pagina 18 Pagina 28 Pagina 31 (1) Accettati anche (2x4mm²) o (1x4mm²)+(1x6mm²) 26

29 Caratteristiche tecniche Interruttori magnetotermici EPC Curve di intervento (EN/IEC ) Effetto della temperatura ambiente sulla corrente nominale Qualora l installazione degli apparecchi avvenga all interno di quadri di distribuzione contenenti altri apparecchi modulari, bisogna applicare un fattore di correzione (K) che tiene in considerazione le condizioni di installazione dell interruttore, la temperatura ambiente ed il numero di circuiti pricipali contenuti nell installazione (EN ): No. di dispositivi 2 o 3 0,9 4 o 5 0,8 6 a 9 0,7 > 10 0,6 La calibrazione dell intervento termico dell interruttore è stata eseguita con una emperatura ambiente pari a 30 C. Condizioni di temperatura ambiente differenti da 30 C influenzano la caratteristica del bimetallo, anticipando o ritardando di conseguenza l intervento termico. K Caratteristiche tecniche Intervento magnetico Un elettromagnete con nucleo mobile assicura un apertura istantanea in caso di corto circuito. Lo standard individua due tipologie differenti di apparecchiature, in base alla corrente necessaria ad avviare l intervento istantaneo: tipo B e C. lcn Corrente empo di apertura Applicazioni (A) di prova B 3 x ln 0,1 < t < 45s (In 32A) Per carichi resistivi quali: 0,1 < t < 90s (In > 32A) - riscaldatori elettrici 5 x ln t < 0,1s - riscaldatori d acqua - stoves C 0,1 < t < 15s (In 32A) Carichi tipici quali: 5 x ln 0,1 < t < 30s (In > 32A) - lampade t < 0,1s - prese 10 x ln - piccoli motori Intervento termico L intervento è avviato tramite un nastro bimetallico in caso di sovraccarico. La norma definisce il campo di intervento termico in base a specifici valori di sovraccarico. La temperatura ambiente di riferimento è 30 C. Corrente di prova empo di apertura 1,13 x ln t 1h (ln 63A) t 2h (ln > 63A) 1,45 x ln t < 1h (ln 63A) t < 2h (ln > 63A) 2,55 x ln 1s < t < 60s (ln 32A) 1s < t < 120s (ln > 32A) Perdite di potenza per polo In (A) Caduta di tensione (V) Potenza persa Pw (W) Impedenza Z (mohm) 2 0,55 1,1 275,00 4 0,34 1,35 84,38 6 0,25 1,52 42, ,16 1,64 16, ,13 2,1 8, ,13 2,52 6, ,12 3,1 4, ,12 3,8 3, ,11 4,46 2,79 27

30 Sistema sbarre Binari per Unibis multipolari EPC Solo per magnetotermici EPC, non per magnetotermici differenziali DPC. Particolarità La particolare sagoma angolata del sistema sbarre consente di connettere, senza alcun adattatore aggiuntivo, un conduttore di sezione fino a 10mm² (Ith max: 63A). Connessione Dati tecnici Binario Rame (oxygen free) Nastro isolante Plastica Autoestinguente V-0 Resistente al calore >96 C Rigidità dielettrica 36kV/mm, secondo DIN 53481/1,2 Resistenza alla traccia Secondo IEC Classe d isolamento 400V, Gruppo C secondo BS/EN Sbarra isolata tipo Pin - forma angolata N. rif. Q. tà imb. Alimentazione: 2P o 1P+N 10 mm² 18 x 2P Distribuzione: Interruttori 2P 10 mm² 55 x 2P - Lunghezza 1m (1) 1 Alimentazione: 3P 10 mm² 12 x 2P Distribuzione: Interruttori 2P 10 mm² 55 x 2P - Lunghezza 1m (1) 1 Alimentazione: 3P+N 10 mm² 55 x 2P - Lunghezza 1m (1) 1 Distribuzione: Interruttori 2P Alimentazione: 3P o 3P+N 10 mm² 55 x 3P/4P - Lunghezza 1m Distribuzione: Con: 4 terminali di collegamento e 4 capucci Interruttori 3P o 4P erminali di collegamento 25 mm² Laterale, a puntale, non isolato Cappucci 10 mm² 2P mm² 3P mm² 4P Dimensioni Pagina 31 (1) Le barrette lunghezza 1 mt possono essere tagliate 28

31 Sistema sbarre Binari unipolari per Unibis EPC Solo per magnetotermici EPC, non per magnetotermici differenziali DPC. Particolarità Connessione Il profilo del sistema sbarre è stato progettato per evitare un morsetto aggiuntivo per realizzare una derivazione con conduttori fino a 10mm² e Ith = max. 63A. Dati tecnici Binario Rame (oxygen free) Nastro isolante Plastica Autoestinguente V-0 Resistente al calore >96 C Rigidità dielettrica 36kV/mm, secondo DIN 53481/1,2 Resistenza alla traccia Secondo IEC Classe d isolamento 415V, Gruppo C secondo BS/EN Sbarra isolata tipo Pin 90 ipo N. rif. Q. tà imb. Alimentazione: 1P 10 mm² 13x1 fase (grigio) VBSGRIG13 EPC Distribuzione: 1P 10 mm² 13x1 neutro (blu) VBSBLUE13 EPC Dimensioni Pagina 31 29

32 Ausiliari Serie CA UN interfaccia EN/IEC Comune a tutti i dispositivi Unibis*: MCB 1P+N, 1P+1P, 2P in 1 mod., 3, 4P in 2 mod., MD 2P in 2 moduli. Esclusa la serie DMA63N. Versione con contatto dorati disponibile per applicazioni con correnti o tensioni basse. Fino a 4 unità sovrapponibili a sinistra o a destra. Permette il passaggio tra sbarre, piedini e basi, dall alto e dal basso, semplicemente cambiando la posizione della base dell ausiliario. Prestazioni Ausiliari Applicazioni Contatti in scambio 1 Corrente nominale In (A) 5 ensione nominale AC (Un) (V) 240 Durata elettrica Capacità dei terminali (cavo flessibile/rigido) (mm²) 2,5 Peso (g) 70 Applicazione Approvazioni / Marchi Accessori Accoppiamento (1) Passaggio attraverso le sbarre Sovrapponibilità Il contatto ausiliario CA UN ha una doppia funzione: 1. La funzione standard di contatto ausiliario. 2. La funzione di interfaccia, che permette l utilizzo di tutti gli ausiliari in combinazione alla gamma di interruttori Unibis*. Esempio: per accoppiare il relè di minima tensione ele U all interruttore Unibis*, il CA deve essere aggiunto tra l interruttore ed il ele U come interfaccia. Contatto ausiliario CA UN H (funzione H) Fornisce lo stato del dispositivo di protezione, APERO/CHIUSO. Segnale o contatto ausiliario CA UN S/H, CA UN S/H G (funzione S/H) ale ausiliario può agire da contatto ausiliario (funzione H) o come contatto di segnalazione (funzione S). L utente può cambiare la funzione al momento dell installazione. Utilizzato come contatto di segnalazione (funzione S) esso fornisce informazione relativa all apertura automatica del dispositivo di protezione: sovraccarico o corto circuito per gli MCB, anche apertura per guasto a terra per i MD. Il dispositivo ha un pulsante di test frontale per simulare il funzionamento (agendo come funzione H o S) Pulsante di reset per i contatti (funzione S) Segnale di apertura frontale (funzione S) (1) Per gli interruttori Unibis* 3P, l accoppiamento è possibile solo sul lato sinistro. Serie CA UN Interfaccia Unibis* Funzione ipo N. rif. Q. tà imb. 1/2 mod. H CA UN H /40 S/H CA UN S/H /40 S/H CA UN S/H G /40 contatti dorati H S Dimensioni Pagina 31 30

33 Dimensioni Interruttori magnetotermici compatti - Serie EPC Ausiliario d interfaccia - Serie CA UN Dimensioni Sbarre isolate Doppio angolo

34 Per numero di riferimento N. rif. ipo Pag N. rif. ipo Pag DPCAi60C16/ DPCAi60C20/ DPCAi60C25/ DPCAi60C32/ DPCAi60C40/ DPCAi60C06/ DPCAi60C10/ DPCAi60C13/ DPCAi60C16/ DPCAi60C20/ DPCAi60C25/ DPCAi60C32/ DPCAi60C40/ DPCA60B06/ DPCA60B10/ DPCA60B13/ DPCA60B16/ DPCA60B20/ DPCA60B25/ DPCA60B32/ DPCA60B40/ DPCA60B06/ DPCA60B10/ DPCA60B13/ DPCA60B16/ DPCA60B20/ DPCA60B25/ DPCA60B32/ DPCA60B40/ DPC100C10/ DPC100C16/ DPC100C10/ DPC100C13/ DPC100C16/ DPC100C20/ DPC100C25/ DPC100C32/ DPC100C40/ DPC100C10/ DPC100C13/ DPC100C16/ DPC100C20/ DPC100C25/ DPC100C32/ DPC100C40/ DPCA100C10/ DPCA100C13/ DPCA100C16/ DPCA100C06/ DPCA100C10/ DPCA100C13/ DPCA100C16/ DPCA100C20/ DPCA100C25/ DPCA100C32/ DPCA100C40/ DPCA100C06/ DPCA100C10/ DPCA100C13/ DPCA100C16/ DPCA100C20/ DPCA100C25/ DPCA100C32/ DPCA100C40/ DPCAi100C06/ DPCAi100C10/ DPCAi100C13/ DPCAi100C16/ DPCAi100C20/ DPCAi100C25/ DPCAi100C32/ DPCAi100C40/ DPCAi100C06/ DPCAi100C10/ DPCAi100C13/ DPCAi100C16/ DPCAi100C20/ DPCAi100C25/ DPCAi100C32/ DPCAi100C40/ DPCA100B10/ DPCA100B13/ DPCA100B16/ DPCA100B06/ DPCA100B10/ DPCA100B13/ DPCA100B16/ DPCA100B20/ DPCA100B25/ DPCA100B32/ DPCA100B40/ DPCA100B06/ DPCA100B10/ N. rif. ipo Pag DPCA100B13/ DPCA100B16/ DPCA100B20/ DPCA100B25/ DPCA100B32/ DPCA100B40/ DPCAi100B06/ DPCAi100B10/ DPCAi100B13/ DPCAi100B16/ DPCAi100B20/ DPCAi100B25/ DPCAi100B32/ DPCAi100B40/ DPCAi100B06/ DPCAi100B10/ DPCAi100B13/ DPCAi100B16/ DPCAi100B20/ DPCAi100B25/ DPCAi100B32/ DPCAi100B40/ VBSGRIG13 EPC VBSBLUE13 EPC CA UN H CA UN S/H CA UN S/H G EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 453 B EPC 453 B EPC 453 B16 23 N. rif. ipo Pag EPC 453 B EPC 453 B EPC 453 B EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B DMA63NC10/ DMA63NC13/ DMA63NC16/ DMA63NC20/ Indice numerico DMA63NC10/ DMA63NC13/ DMA63NC16/ DMA63NC20/ DMA63NC25/ DMA63NC32/ DMA63NB10/ DMA63NB13/ DMA63NB16/ DMA63NB20/ DMA63NB25/ DMA63NB32/ DMA63NB10/ DMA63NB13/ DMA63NB16/ DMA63NB20/ DMA63NB25/ DMA63NB32/ DMA63NC32/ DMA63NC25/ CAH DMA63N DPC45C06/ DPC45C10/ DPC45C13/ DPC45C16/ DPC45C20/ DPC45C25/ DPC45C32/ DPC45C40/ DPC45C06/ DPC45C10/ DPC45C13/ DPC45C16/ DPC45C20/ DPC45C25/ DPC45C32/ DPC45C40/ DPCA45C06/ DPCA45C10/ DPCA45C13/ DPCA45C16/ DPCA45C20/ DPCA45C25/ DPCA45C32/ DPCA46C40/ DPCA45C06/ DPCA45C10/ DPCA45C13/ DPCA45C16/ DPCA45C20/ DPCA45C25/ DPCA45C32/ DPCA45C40/ DPC60C06/ DPC60C10/ DPC60C13/ DPC60C16/ DPC60C20/ DPC60C25/ DPC60C32/ DPC60C40/ DPC60C06/ DPC60C10/ DPC60C13/ DPC60C16/ DPC60C20/ DPC60C25/ DPC60C32/ DPC60C40/ DPCA60C06/ DPCA60C10/ DPCA60C13/ DPCA60C16/ DPCA60C20/ DPCA60C25/ DPCA60C32/ DPCA60C40/ DPCA60C06/ DPCA60C10/ DPCA60C13/ DPCA60C16/ DPCA60C20/ DPCA60C25/ DPCA60C32/ DPCA60C40/ DPCAi60C06/ DPCAi60C10/ DPCAi60C13/

35 Per tipo ipo N. rif. Pag C CA UN H CA UN S/H CA UN S/H G CAH DMA63N D DMA63NB10/ DMA63NB10/ DMA63NB13/ DMA63NB13/ DMA63NB16/ DMA63NB16/ DMA63NB20/ DMA63NB20/ DMA63NB25/ DMA63NB25/ DMA63NB32/ DMA63NB32/ DMA63NC10/ DMA63NC10/ DMA63NC13/ DMA63NC13/ DMA63NC16/ DMA63NC16/ DMA63NC20/ DMA63NC20/ DMA63NC25/ DMA63NC25/ DMA63NC32/ DMA63NC32/ DPC100C10/ DPC100C10/ DPC100C10/ DPC100C13/ DPC100C13/ DPC100C16/ DPC100C16/ DPC100C16/ DPC100C20/ DPC100C20/ DPC100C25/ DPC100C25/ DPC100C32/ DPC100C32/ DPC100C40/ DPC100C40/ DPC45C06/ DPC45C06/ DPC45C10/ DPC45C10/ DPC45C13/ DPC45C13/ DPC45C16/ DPC45C16/ DPC45C20/ DPC45C20/ DPC45C25/ DPC45C25/ DPC45C32/ DPC45C32/ DPC45C40/ DPC45C40/ DPC60C06/ DPC60C06/ DPC60C10/ DPC60C10/ DPC60C13/ DPC60C13/ DPC60C16/ DPC60C16/ DPC60C20/ DPC60C20/ DPC60C25/ DPC60C25/ DPC60C32/ DPC60C32/ DPC60C40/ DPC60C40/ DPCA100B06/ DPCA100B06/ DPCA100B10/ DPCA100B10/ DPCA100B10/ DPCA100B13/ DPCA100B13/ DPCA100B13/ DPCA100B16/ DPCA100B16/ DPCA100B16/ DPCA100B20/ DPCA100B20/ DPCA100B25/ DPCA100B25/ ipo N. rif. Pag DPCA100B32/ DPCA100B32/ DPCA100B40/ DPCA100B40/ DPCA100C06/ DPCA100C06/ DPCA100C10/ DPCA100C10/ DPCA100C10/ DPCA100C13/ DPCA100C13/ DPCA100C13/ DPCA100C16/ DPCA100C16/ DPCA100C16/ DPCA100C20/ DPCA100C20/ DPCA100C25/ DPCA100C25/ DPCA100C32/ DPCA100C32/ DPCA100C40/ DPCA100C40/ DPCA45C06/ DPCA45C06/ DPCA45C10/ DPCA45C10/ DPCA45C13/ DPCA45C13/ DPCA45C16/ DPCA45C16/ DPCA45C20/ DPCA45C20/ DPCA45C25/ DPCA45C25/ DPCA45C32/ DPCA45C32/ DPCA45C40/ DPCA46C40/ DPCA60B06/ DPCA60B06/ DPCA60B10/ DPCA60B10/ DPCA60B13/ DPCA60B13/ DPCA60B16/ DPCA60B16/ DPCA60B20/ DPCA60B20/ DPCA60B25/ DPCA60B25/ DPCA60B32/ DPCA60B32/ DPCA60B40/ DPCA60B40/ DPCA60C06/ DPCA60C06/ DPCA60C10/ DPCA60C10/ DPCA60C13/ DPCA60C13/ DPCA60C16/ DPCA60C16/ DPCA60C20/ DPCA60C20/ DPCA60C25/ DPCA60C25/ DPCA60C32/ DPCA60C32/ DPCA60C40/ DPCA60C40/ DPCAi100B06/ DPCAi100B06/ DPCAi100B10/ DPCAi100B10/ DPCAi100B13/ DPCAi100B13/ DPCAi100B16/ DPCAi100B16/ DPCAi100B20/ DPCAi100B20/ DPCAi100B25/ DPCAi100B25/ DPCAi100B32/ DPCAi100B32/ DPCAi100B40/ DPCAi100B40/ DPCAi100C06/ DPCAi100C06/ DPCAi100C10/ DPCAi100C10/ DPCAi100C13/ DPCAi100C13/ ipo N. rif. Pag DPCAi100C16/ DPCAi100C16/ DPCAi100C20/ DPCAi100C20/ DPCAi100C25/ DPCAi100C25/ DPCAi100C32/ DPCAi100C32/ DPCAi100C40/ DPCAi100C40/ DPCAi60C06/ DPCAi60C06/ DPCAi60C10/ DPCAi60C10/ DPCAi60C13/ DPCAi60C13/ DPCAi60C16/ DPCAi60C16/ DPCAi60C20/ DPCAi60C20/ DPCAi60C25/ DPCAi60C25/ DPCAi60C32/ DPCAi60C32/ DPCAi60C40/ DPCAi60C40/ E EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N B EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 451N C EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 B EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 452 C EPC 453 B EPC 453 B EPC 453 B EPC 453 B EPC 453 B EPC 453 B EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 453 C EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 454 B EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 454 C EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 B EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 611 C EPC 61N B EPC 61N B ipo N. rif. Pag EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N B EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 61N C EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 B EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 62 C EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 B EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 63 C EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 B EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C EPC 64 C V VBSBLUE13 EPC VBSGRIG13 EPC La politica di GE è improntata al miglioramento continuo. Il design o i particolari strutturali sono soggetti a modifiche senza obbligo di preavviso. Giugno 2016 GE Industrial Solutions Indice numerico 33

Interruttori magnetotermici differenziali compatti DPC Interruttori magnetotermici compatti EPC

Interruttori magnetotermici differenziali compatti DPC Interruttori magnetotermici compatti EPC GE Industrial Solutions Novità Unibis Interruttori magnetotermici differenziali compatti DPC Interruttori magnetotermici compatti EPC Risparmiare fino al 50% di spazio nei quadri di distribuzione GE imagination

Dettagli

Interruttori magnetotermici differenziali compatti. Serie DC90. 2 Poli protetti fino a 40A. Low Voltage

Interruttori magnetotermici differenziali compatti. Serie DC90. 2 Poli protetti fino a 40A. Low Voltage Low Voltage Interruttori magnetotermici differenziali compatti erie DC90 Poli protetti fino a lettra rl Via Lisbona 8, int. 5 57 Padova el. +9 0498075544 Fax +9 049807795 -mail info@aegelettra.it Web www.aegelettra.it

Dettagli

Interruttori differenziali di Tipo B e di Tipo F

Interruttori differenziali di Tipo B e di Tipo F GE Industrial Solutions Interruttori differenziali di Tipo B e di Tipo F La protezione completa per le persone e gli impianti ge.com/it/industrialsolutions Tipo B applicazioni Inverter e azionamenti Caricatori

Dettagli

S 200 L, S 200, S 200 M

S 200 L, S 200, S 200 M Gli interruttori magnetotermici proteggono le installazioni da sovraccarichi e corto circuiti, assicurando affidabilità e sicurezza nelle operazioni. La nuova serie S 00 System pro M compact soddisfa le

Dettagli

Serie 90 MCB Apparecchi modulari per protezione circuiti

Serie 90 MCB Apparecchi modulari per protezione circuiti Apparecchi modulari per protezione circuiti La consente di soddisfare qualsiasi esigenza di protezione da sovraccarico e cortocircuiti, per tutte le applicazioni civili, terziarie e industriali. La gamma

Dettagli

GE Industrial Solutions. Novità. TeleREC. GE imagination at work. TeleREC 2 / TeleREC Top / TeleREC Plus Sistemi di riarmo automatico

GE Industrial Solutions. Novità. TeleREC. GE imagination at work. TeleREC 2 / TeleREC Top / TeleREC Plus Sistemi di riarmo automatico GE Industrial Solutions Novità TeleREC TeleREC 2 / TeleREC Top / TeleREC Plus Sistemi di riarmo automatico GE imagination at work 1 Introduzione 2 Caratteristiche e vantaggi GAMMA 4 TeleREC 2 - Differenziali

Dettagli

90 RCD INTERRUTTORI MODULARI PER PROTEZIONE DIFFERENZIALE

90 RCD INTERRUTTORI MODULARI PER PROTEZIONE DIFFERENZIALE INTERRUTTORI MAGNETOTERMICI DIFFERENZIALI COMPATTI MDC Dati tecnici TIPO MDC 45 MDC 60 MDC 100 MDC 100 MA Norma di riferimento EN 61009-1 EN 61009-1 EN 61009-1 EN 61009-1 Corrente nominale (In) (A) 6-32

Dettagli

Interruttori magnetotermici differenziali DS201 Caratteristiche tecniche

Interruttori magnetotermici differenziali DS201 Caratteristiche tecniche Interruttori magnetotermici differenziali Caratteristiche tecniche CARATTERISTICHE TECNICHE Norme di riferimento Caratteristiche Tipo (forma d onda del guasto a terra) elettriche Poli Corrente nominale

Dettagli

Serie 90 RCD Apparecchi modulari per protezione differenziale

Serie 90 RCD Apparecchi modulari per protezione differenziale 90 RCD Apparecchi modulari per protezione differenziale La 90 RCD si compone di: MDC. Interruttori magnetotermici differenziali compatti monoblocco da 6 a 32 A, in curva B e C, potere di interruzione fino

Dettagli

Interruttori magnetotermici Serie S 280 caratteristiche tecniche

Interruttori magnetotermici Serie S 280 caratteristiche tecniche Interruttori magnetotermici Serie S 80 caratteristiche tecniche S 80 CSC400474F001 S 80 80-100 A Dati generali Norme di riferimento CEI EN 60898-1, CEI EN 60947- Poli 1P, P, 3P, 4P Caratteristiche di intervento

Dettagli

Interruttori magnetotermici Serie S 290 caratteristiche tecniche

Interruttori magnetotermici Serie S 290 caratteristiche tecniche Interruttori magnetotermici Serie S 90 caratteristiche tecniche S 90 Norme di riferimento CEI EN 60898, CEI EN 60947- Corrente nominale In [A] 80 In 100 Poli P. 4P Tensione nominale Ue P, 4P [V] 30-400

Dettagli

Linea Modulare Plus. Linea Centralino. Protezione delle linee. Protezione delle persone. Estensioni (ausiliari elettrici)

Linea Modulare Plus. Linea Centralino. Protezione delle linee. Protezione delle persone. Estensioni (ausiliari elettrici) Linea Modulare Plus Linea entralino Protezione delle linee Protezione delle persone stensioni (ausiliari elettrici) omando, controllo, segnalazione, misura ontenitori per distribuzione terminale onnessione

Dettagli

Pag. 13-2 Pag. 13-6. Pag. 13-7

Pag. 13-2 Pag. 13-6. Pag. 13-7 Pag. -2 Pag. -6 INTERRUTTORI MAGNETOTERMICI FINO A 63A Versioni: 1P, 1P+N, 2P, 3P, 4P. Corrente nominale In: 1 63A. Potere di interruzione nominale Icn: 10kA (6kA per 1P+N). Curva di intervento: tipo B,

Dettagli

Interruttori di manovra-sezionatori

Interruttori di manovra-sezionatori Siemens S.p.A. 2014 Nuovo design per un utilizzo più confortevole Comando affidabile I nuovi interruttori di manovra-sezionatori 5TL1 vengono installati per il comando di impianti di illuminazione, per

Dettagli

Pag Pag Pag

Pag Pag Pag Pag. -2 Pag. -10 INTERRUTTORI MAGNETOTERMICI FINO A 63A Versioni: 1P, 1P+N, 2P, 3P, 4P. Corrente nominale In: 1 63A. Potere di interruzione nominale Icn: 10kA (6kA per 1P+N). Curva di intervento: tipo

Dettagli

Interruttori differenziali puri: Blocchi differenziali: Interruttori differenziali magnetotermici:

Interruttori differenziali puri: Blocchi differenziali: Interruttori differenziali magnetotermici: Gli interruttori differenziali assicurano la protezione delle persone e degli impianti dalle correnti di guasto a terra, dividendosi in tre categorie. - Interruttori differenziali puri: sono sensibili

Dettagli

Interruttori magnetotermici differenziali DS 901 L La nuova protezione per gli ambienti domestici

Interruttori magnetotermici differenziali DS 901 L La nuova protezione per gli ambienti domestici Interruttori magnetotermici differenziali DS 901 L La nuova protezione per gli ambienti domestici Interruttori magnetotermici differenziali DS 901 L In due soli moduli, una sicurezza completa per la tua

Dettagli

Interruttori magnetotermici MS 132 La protezione Prima di tutto

Interruttori magnetotermici MS 132 La protezione Prima di tutto Interruttori magnetotermici MS 132 La protezione Prima di tutto Versatilità straordinaria in un unica larghezza. La flessibilità di utilizzo di una gamma sempre efficace per motori fino a 15kW (32A-400Vca)

Dettagli

Serie 34 - Relè elettromeccanico per circuito stampato 6 A. Caratteristiche 34.51

Serie 34 - Relè elettromeccanico per circuito stampato 6 A. Caratteristiche 34.51 Serie 34 - Relè elettromeccanico per circuito stampato 6 A Caratteristiche 34. Ultra sottile con contatto - 6 A Montaggio su circuito stampato - diretto o su zoccoli da circuito stampato Montaggio su barra

Dettagli

Btdin Modulo differenziale associabile 125A per interruttori 1,5 moduli per polo

Btdin Modulo differenziale associabile 125A per interruttori 1,5 moduli per polo Sommario Pagine 1. Descrizione... 2 2. Gamma... 2 3. Dati dimensionali... 2 4. Messa in opera - collegamento... 3 5. Caratteristiche generali... 4 6. Conformità e certificazioni... 6 7. Curve caratteristiche...

Dettagli

INTERRUTTORI AD USO DOMESTICO CON POTERE DI INTERRUZIONE 4,5KA

INTERRUTTORI AD USO DOMESTICO CON POTERE DI INTERRUZIONE 4,5KA INTERRUTTORI AD USO DOMESTICO CON POTERE DI INTERRUZIONE 4,5KA Italclem ha introdotto nella propria gamma una rinnovata versione di interruttori automatici e differenziali magnetotermici con potere di

Dettagli

POWER CATALISTINO 2016 CATALISTINO 2016 LIGHTING CATALISTINO POWER 2016 CATALISTINO

POWER CATALISTINO 2016 CATALISTINO 2016 LIGHTING CATALISTINO POWER 2016 CATALISTINO CATALISTINO 2016 Abbiamo fatto una scelta ben precisa: innovare. Creare ogni giorno qualcosa di meglio rispetto al giorno precedente. Esplorare nuove strade che nessuno ha mai percorso. Questa è la nostra

Dettagli

S800 PV-S, S800 PV-M, F200 PV B

S800 PV-S, S800 PV-M, F200 PV B S800 PV-S, S800 PV-M, F200 PV B Interruttori, sezionatori e interruttori differenziali tipo B per impianti fotovoltaici 2CSC413001B0902 Interruttori magnetotermici e sezionatori per corrente continua specifici

Dettagli

Nasce l interruttore SN201

Nasce l interruttore SN201 Nasce l interruttore SN201 Profilo ideale 2CSC402001B0901 Nuovi interruttori automatici magnetotermici 1P+N in un modulo SN201 Armonia tecnologica La serie SN201 è conforme alle Norme CEI EN 60898-1 e

Dettagli

1 contatto, 10 A Contatti in AgNi + Au Morsetti a vite Montaggio su barra 35 mm (EN 60715) 7.xxx.5050

1 contatto, 10 A Contatti in AgNi + Au Morsetti a vite Montaggio su barra 35 mm (EN 60715) 7.xxx.5050 Serie 49 - Interfaccia modulare a relè 8-10 - 16 A 49 Caratteristiche 49.31-50x0 49.52/72-50x0 1 o 2 contatti - Interfaccia modulare a relè Contatti dorati (5 µm) per la commutazione di bassi carichi 49.31-50x0-1

Dettagli

RM4UA03F RELÈ MISURAZIONE TENSIONE RM4-U - INTERVALLO V VAC

RM4UA03F RELÈ MISURAZIONE TENSIONE RM4-U - INTERVALLO V VAC Caratteristiche RELÈ MISURAZIONE TENSIONE RM4-U - INTERVALLO 30..500V - 110-130 VAC Presentazione Gamma prodotto Tipo di prodotto o componente Tipo relè Nome relè Parametri relè controllati Tipo temporizzazione

Dettagli

Scaricatori e limitatori di sovratensione

Scaricatori e limitatori di sovratensione 5SD741 e 5SD748 Scaricatori di sovratensione di origine atmosferica Tipo 1 / 2 Caratteristiche Gli scaricatori di Tipo 1 / 2 sono dispositivi, in esecuzione compatta, che possono essere installati sia

Dettagli

Interruttori magnetotermici modulari

Interruttori magnetotermici modulari Interruttori magnetotermici modulari Interruttori magnetotermici 1P+N in un modulo Gli interruttori magnetotermici modulari 1P+N fanno parte del System pro M e sono dotati di dispositivo di attacco rapido

Dettagli

Low Voltage. Sistema modulare 90. Catalogo generale

Low Voltage. Sistema modulare 90. Catalogo generale Low Voltage Sistema modulare 90 Catalogo generale Edizione 1/2008 Sviluppo storico degli Interruttori automatici 1905 Dai laboratori dell AEG proposte per i primi interruttori da 530A, 250V per protezione

Dettagli

2 contatti, 6 A Passo 5 mm Montaggio su circuito stampato o zoccoli serie 95

2 contatti, 6 A Passo 5 mm Montaggio su circuito stampato o zoccoli serie 95 Serie 44 - Mini relè per circuito stampato 6-10 A Caratteristiche 44.52 44.62 Relè con 2 contatti 44.52-2 contatti 6 A (passo 5 mm) 44.62-2 contatti 10 A (passo 5 mm) Montaggio su circuito stampato - diretto

Dettagli

Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore fluorescenti compatte (CFL) W

Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore fluorescenti compatte (CFL) W Serie - Contattori modulari 25 A SERIE Caratteristiche.32.0.xxx.1xx0.32.0.xxx.4xx0 Contattore modulare 25 A - 2 contatti Larghezza 17.5 mm Apertura contatti NO 3 mm, doppia rottura Bobina e contatti per

Dettagli

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N SENTRON Interruttori di manovra-sezionatori L, K, N Interruttori di manovra-sezionatori KA e KE fino a 1000 A Schema assemblaggio n Schema assemblaggio 1 2 NSE0_0191b 4 5 6 7 1 Contatti ausiliari (SB per

Dettagli

System pro M compact Interruttori magnetotermici S A-100A

System pro M compact Interruttori magnetotermici S A-100A System pro M compact Interruttori magnetotermici S 200 80A-100A Introduzione Perfettamente integrati nella gamma System pro M compact, gli interruttori S 200 nascono per proteggere gli impianti dalle condizioni

Dettagli

Serie 34 - Relè elettromeccanico per circuito stampato 6 A. Caratteristiche SERIE

Serie 34 - Relè elettromeccanico per circuito stampato 6 A. Caratteristiche SERIE Serie 34 - Relè elettromeccanico per circuito stampato 6 SERIE 34 Caratteristiche 34.51 Ultra sottile con 1 contatto - 6 Montaggio su circuito stampato - diretto o su zoccoli da circuito stampato Montaggio

Dettagli

SERIE 44 Mini relè per circuito stampato 6-10 A

SERIE 44 Mini relè per circuito stampato 6-10 A SERIE Mini relè per circuito stampato 6-10 SERIE Relè 2 contatti in scambio ad elevato isolamento tra contatti adiacenti Montaggio su circuito stampato o ad innesto su zoccolo Tipo.52 -- 2 scambi 6 (passo

Dettagli

2 contatti, 6 A Passo 5 mm Montaggio su circuito stampato o zoccoli serie 95. 8/5 - (12/5 sensibile) 8/5 - (12/5 sensibile)

2 contatti, 6 A Passo 5 mm Montaggio su circuito stampato o zoccoli serie 95. 8/5 - (12/5 sensibile) 8/5 - (12/5 sensibile) Serie - Mini relè per circuito stampato 6-10 SERIE Caratteristiche.52.62 Relè con 2 contatti.52-2 contatti 6 (passo 5 mm).62-2 contatti 10 (passo 5 mm) Montaggio su circuito stampato - diretto o su zoccolo

Dettagli

CARATTERISTICHE TECNICHE COMPORTAMENTO AGLI AGENTI CHIMICI ED ATMOSFERICI

CARATTERISTICHE TECNICHE COMPORTAMENTO AGLI AGENTI CHIMICI ED ATMOSFERICI 40 CDe - Centralini da parete standard Spagnolo Normativa: EN 60670-1; IEC 60670-24 Grado di protezione: IP 40 Protezione contro i contatti indiretti: doppio isolamento - Temperatura di installazione:

Dettagli

SERIE 48 Interfaccia modulare a relè 8 A

SERIE 48 Interfaccia modulare a relè 8 A SERIE Interfaccia modulare a relè 8 A SERIE 2 contatti - Interfaccia modulare a relè con contatti guidati, larghezza 15.8 mm Tipo.12-2 scambio 8 A - Relè per circuito stampato con contatti guidati secondo

Dettagli

SIDERMAT. Interruttori di manovra sezionatori con bobina di sgancio da 250 a 1800 A. Interruttori-sezionatori per la distribuzione di energia

SIDERMAT. Interruttori di manovra sezionatori con bobina di sgancio da 250 a 1800 A. Interruttori-sezionatori per la distribuzione di energia SIDERMAT Interruttori-sezionatori per la distribuzione di energia appli_316_a sdmat_066_a_1_cat Interruttori di manovra sezionatori con bobina di sgancio da 250 a 1800 A  Funzione  Caratteristiche generali

Dettagli

55.34T. SERIE 55 Relè per applicazioni ferroviarie 7 A. Relè per impieghi generali Montaggio ad innesto su zoccolo 4 scambi, 7 A

55.34T. SERIE 55 Relè per applicazioni ferroviarie 7 A. Relè per impieghi generali Montaggio ad innesto su zoccolo 4 scambi, 7 A SERIE Relè per applicazioni ferroviarie 7 A SERIE Relè per impieghi generali Montaggio ad innesto su zoccolo 4 scambi, 7 A Conformi alle normative EN 445-2:2013 (protezione contro fuoco e fumi), EN 61373

Dettagli

Serie 41 - Mini relè per circuito stampato A. Caratteristiche SERIE

Serie 41 - Mini relè per circuito stampato A. Caratteristiche SERIE Serie 41 - Mini relè per circuito stampato 8-12 - 16 SERIE 41 Caratteristiche 41.31 41.52 41.61 1 o 2 scambi - Basso profilo (altezza 15.7 mm) 41.31-1 contatto 12 (passo 3.5 mm) 41.52-2 contatti 8 (passo

Dettagli

xxx.1xx xxx.4xx0. Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore

xxx.1xx xxx.4xx0. Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore Serie 22 - Contattori modulari 25-40 - 63 SERIE 22 Caratteristiche 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 Contattore modulare 25-2 contatti arghezza 17.5 mm pertura contatti NO 3 mm, doppia rottura Bobina e

Dettagli

2CSC421002B0901. Protezione differenziale senza interventi intempestivi Interruttori e blocchi differenziali AP

2CSC421002B0901. Protezione differenziale senza interventi intempestivi Interruttori e blocchi differenziali AP 2CSC421002B0901 Protezione differenziale senza interventi intempestivi Interruttori e blocchi differenziali AP Il problema Gli interventi intempestivi In caso di perturbazioni sulla rete elettrica, gli

Dettagli

Btdin Modulo differenziale associabile 32A - 63A per interruttori 1 modulo per polo

Btdin Modulo differenziale associabile 32A - 63A per interruttori 1 modulo per polo Sommairio Pagine 1. Descrizione... 2 2. Gamma... 2 3. Dati dimensionali... 2 4. Messa in opera - collegamento... 3 5. Caratteristiche generali... 4-6 6. Conformità e certificazioni... 6 7. Curve caratteristiche...

Dettagli

SERIE 41 Mini relè per circuito stampato A. Passo 3.5 mm 1 contatto 12 A Montaggio su circuito stampato o zoccoli serie 95

SERIE 41 Mini relè per circuito stampato A. Passo 3.5 mm 1 contatto 12 A Montaggio su circuito stampato o zoccoli serie 95 SERIE Mini relè per circuito stampato 8-12 - 16 SERIE 1 o 2 scambi - Basso profilo (altezza 15.7 mm).31-1 contatto 12 (passo 3.5 mm).52-2 contatti 8 (passo 5 mm).61-1 contatto 16 (passo 5 mm) Montaggio

Dettagli

Linea Modulare Plus. Linea Centralino. Protezione delle linee. Protezione delle persone. Estensioni (ausiliari elettrici)

Linea Modulare Plus. Linea Centralino. Protezione delle linee. Protezione delle persone. Estensioni (ausiliari elettrici) inea Modulare Plus.2.3 Presentazione della gamma Possibilità di accorpare gli ausiliari con interruttori magnetotermici e interruttori differenziali.4 ontatti ausiliari - Serie.5.6 ontatti ausiliari -

Dettagli

INSTALLAZIONE CIVILE Protezione

INSTALLAZIONE CIVILE Protezione Protezione Limitatore di sovratensione (SPD) Campo di applicazione L apparecchio fornisce la protezione delle prese di alimentazione di tutti i tipi di elettrodomestici ed in particolare di quelli contenenti

Dettagli

Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore. 2 NO 1 NO + 1 NC 2 NC (x3x0) (x5x0) (x4x0)

Materiale contatti AgNi, adatto per carichi resistivi, debolmente induttivi e carichi motore. 2 NO 1 NO + 1 NC 2 NC (x3x0) (x5x0) (x4x0) Serie - Contattori modulari 25-40 - 63 SERIE Caratteristiche Contattore modulare 25-2 contatti.32.0.xxx.1xx0.32.0.xxx.4xx0 Larghezza 17.5 mm pertura contatti NO 3 mm, doppia rottura Bobina e contatti per

Dettagli

LIMITATORI DI SOVRATENSIONE (SPD)

LIMITATORI DI SOVRATENSIONE (SPD) LIMITATORI DI SOVRATENSIONE (SPD) SCARICATORE DI CORRENTE DA FULMINE classe I (B) SCARICATORE con circuito composto da spinterometro autoestinguente non soffiante, per la protezione da sovratensione di

Dettagli

Serie 55 - Relè industriale 7-10 A. Caratteristiche Relè per impieghi generali con 2, 3 o 4 contatti

Serie 55 - Relè industriale 7-10 A. Caratteristiche Relè per impieghi generali con 2, 3 o 4 contatti Serie 55 - Relè industriale 7-10 A Caratteristiche 55.12 55.13 55.14 Relè per impieghi generali con 2, 3 o 4 contatti Montaggio su circuito stampato 55.12-2 contatti 10 A 55.13-3 contatti 10 A 55.14-4

Dettagli

Serie DS. Interruttori di manovra-sezionatori NOVITÀ.

Serie DS. Interruttori di manovra-sezionatori NOVITÀ. Serie DS Interruttori di manovra-sezionatori NOVITÀ www.bremasersce.it Informazioni sul prodotto 35 mm Gli interruttori di manovra-sezionatori della nuova serie DS sono caratterizzati da elevate prestazioni

Dettagli

Sovracorrenti negli edifici

Sovracorrenti negli edifici Sovracorrenti negli edifici Generalità E trattato l impiego degli interruttori magnetotermici modulari (MCBs: Miniature Circuit Breakers) nell edilizia residenziale, intendendo per edifici residenziali

Dettagli

Serie 38 - Interfaccia modulare a relè A

Serie 38 - Interfaccia modulare a relè A Serie 38 - Interfaccia modulare a relè 0.1-2 - 3-5 - 6-8 - 16 A SERIE 38 Caratteristiche Estrazione del relè tramite il ponticello plastico di ritenuta e sgancio Fornito con circuito di presenza tensione

Dettagli

M4 Interruttori magnetotermici e sezionatori MS4

M4 Interruttori magnetotermici e sezionatori MS4 Viale Borri, 231, 21100 Varese, Italia Telefono :+39 0332 279111 M4 SOMMARIO PAGINE 1. USO 1 2. GAMMA 1 3. DIMENSIONI 1 4. INTRODUZIONE 2 5. CARATTERISTICHE ELETTRICHE E MECCANICHE 2 6. NORMATIVE 4 7.

Dettagli

Aggiornamento Catalogo SENTRON 02/2012 1

Aggiornamento Catalogo SENTRON 02/2012 1 1 Introduzione 2 Trasformatori per campanello Caratteristiche generali Il tipico impiego dei trasformatori per campanello è l alimentazione, per brevi periodi, di dispositivi come campanelli, ronzatori,

Dettagli

Componenti per impianti fotovoltaici

Componenti per impianti fotovoltaici Componenti per impianti fotovoltaici Quadri Stringa Conext 150 Interruttori automatici in CC C60PV-DC 152 Interruttore non automatico in CC C60NA-DC 153 Interruttore non automatico in CC SW60-DC 154 Basi

Dettagli

Linea Modulare Plus ED.04

Linea Modulare Plus ED.04 Linea Modulare Plus.04 onsumer & Industrial Power Protection pparecchi modulari e centralini Linea MS imagination at work Tutta la sicurezza ch .2.4 Introduzione Interruttori magnetotermici Interruttori

Dettagli

Bastano 500 Euro netti di spesa per avere prezzi senza precedenti! La convenienza di un impianto fotovoltaico comincia da ABB.

Bastano 500 Euro netti di spesa per avere prezzi senza precedenti! La convenienza di un impianto fotovoltaico comincia da ABB. Cattura la convenienza! Scopri la strepitosa promozione sui prodotti ABB per il fotovoltaico. RISERVATO AGLI INSTALLATORI DI MATERIALE ELETTRICO Bastano 500 Euro netti di spesa per avere prezzi senza precedenti!

Dettagli

Fusibili NEOZED. Indice 9/9

Fusibili NEOZED. Indice 9/9 Indice 9/0 Caratteristiche generali 9/5 Gamma di prodotto 5SG7 e 5SG7 7 9/7 Sezionatori MINIZED 5SG7 6 9/9 Sezionatori NEOZED 5SG e 5SG5 9/20 Basi NEOZED P e 3P 5SH5 2 e 5SH4 9/23 Coperture e portacartucce

Dettagli

StartUp. Sistemi di Riarmo Automatico. Low Voltage

StartUp. Sistemi di Riarmo Automatico. Low Voltage Low Voltage StartUp Sistemi di Riarmo utomatico Elettra Srl Via Lisbona 8, int. 5 517 Padova Tel. +9 0980755 Fax +9 098077695 E-mail info@aegelettra.it Web www.aegelettra.it Sistemi di Riarmo utomatico

Dettagli

Interruttori Magnetotermici per impieghi speciali

Interruttori Magnetotermici per impieghi speciali Siemens 0 Interruttori Magnetotermici per impieghi speciali Low Voltage - Circuit Protection Le nuove famiglie di interruttori magnetotermici SY...-.KK e SY...-.KK possono essere impiegate per la protezione

Dettagli

3 contatti, 10 A Montaggio su circuito stampato. 2 scambi 3 scambi 4 scambi Corrente nominale/max corrente istantanea A

3 contatti, 10 A Montaggio su circuito stampato. 2 scambi 3 scambi 4 scambi Corrente nominale/max corrente istantanea A Serie 55 - Relè industriale 7-10 SERIE 55 Caratteristiche 55.12 55.13 55.14 Relè per impieghi generali con 2, 3 o 4 contatti Montaggio su circuito stampato 55.12-2 contatti 10 55.13-3 contatti 10 55.14-4

Dettagli

Indice. Interruttori sezionatori E E /2. Interruttori sezionatori rotativi RS /4

Indice. Interruttori sezionatori E E /2. Interruttori sezionatori rotativi RS /4 Altri apparecchi modulari Apparecchi di comando Indice Interruttori sezionatori E 0 - E 70.../ Interruttori sezionatori rotativi RS 70.../ Interruttori, deviatori, commutatori E 0... /6 Pulsanti e gemme

Dettagli

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N n Schema assemblaggio SENTRON Interruttori di manovra-sezionatori L, K, N Interruttori di manovra-sezionatori con fusibili KM fino a 400 A Schema assemblaggio 7 2 NSE0_0557b 4 5 6 7 9 SENTRON KL e SENTRON

Dettagli

Interruttori magnetotermici e differenziali

Interruttori magnetotermici e differenziali Interruttori magnetotermici e differenziali Al servizio del cliente UFFICIO VENDITE Tel. 035 4282421 Fax 035 42824 vendite@lovatoelectric.com ASSISTENZA TECNICA Tel. 035 4282422 Fax 035 4282295 service@lovatoelectric.com

Dettagli

NR2 TERMICI È REL 1 1

NR2 TERMICI È REL 1 1 NR2 1 RELÈ TERMICI CARATTERISTICHE GENERALI Frequenza: 50/60 Hz AC; Tensione: fino ai 690Vac; Taratura: 0.1A ~ 630A; Temperatura di funzionamento: -25 C ~ +80 C; Altitudine max: 2000m; Normativa standard:

Dettagli

Caratteristiche elettriche Interruttori differenziali ID

Caratteristiche elettriche Interruttori differenziali ID Guida tecnica Caratteristiche elettriche Interruttori differenziali ID tipo ID norma di riferimento CEI EN 61008-1 classe AC corrente nominale [A] In 25 40 63 80 100 d impiego massima [V] Ue 2P 230 230

Dettagli

Interruttori automatici. Indice

Interruttori automatici. Indice Interruttori automatici Indice Generalità.../ Prospetto riassuntivo e poteri di interruzione... /4 Gamma S 9.../7 Gamma S.../17 Gamma S 90.../47 Gamma S 500.../55 Gamma S 700.../67 /1 Interruttori automatici

Dettagli

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003 Relè di protezione elettrica rifase, rifase con neutro, Monofase, Multifunz. Modello DPC02 B003 Descrizione del prodotto Selezione del modello Relè per il monitoraggio di massima e minima tensione, massima

Dettagli

Interruttori Magnetotermici per corrente continua 5SY5 4

Interruttori Magnetotermici per corrente continua 5SY5 4 Interruttori Magnetotermici per corrente continua 5SY5 BETA Soluzioni per sistemi fotovoltaici 7 Sistemi Fotovoltaici L elevata tensione di esercizio presente in questo tipo di impianti, specialmente a

Dettagli

COMMUTAZIONE AUTOMATICA E la funzione che governa la commutazione tra due linee in un tempo regolabile fra 0,5 e 120 secondi.

COMMUTAZIONE AUTOMATICA E la funzione che governa la commutazione tra due linee in un tempo regolabile fra 0,5 e 120 secondi. Pag. 1/5 1. DESCRIZIONE Il commutatore automatico di rete ATK viene utilizzato per la commutazione automatica del carico da una linea principale (MAIN LINE) ad una di sicurezza o di riserva (SECONDARY

Dettagli

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N

SENTRON Interruttori di manovra-sezionatori 3L, 3K, 3N SENTRON Interruttori di manovra-sezionatori L, K, N Informazioni generali n Informazioni generali NP5 0 NP5 2 NP5 4 Gamma di sezionatori a fusibili SENTRON NP5 I sezionatori a fusibili SENTRON NP5 sono

Dettagli

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003 Relè di protezione elettrica rifase, rifase con neutro, Monofase, Multifunz. Modello DPC02 B003 Descrizione del prodotto Selezione del modello Relè per il monitoraggio di massima e minima tensione, massima

Dettagli

Serie 55 - Relè industriale 7-10 A

Serie 55 - Relè industriale 7-10 A Serie - Relè industriale - 0 A - Montaggio su circuito stampato - Bobina A o D - Disponibile versione RT III (lavabile)... - contatti, 0 A - Montaggio su circuito stampato - contatti, 0 A - Montaggio su

Dettagli

Scaricatori e limitatori di sovratensione

Scaricatori e limitatori di sovratensione Caratteristiche Rispondenza normativa: SPD Classe di prova II secondo IEC 61 3-1; scaricatore Classe C secondo DIN VDE 06754-6; SPD Tipo 2 secondo CEI EN 61 3- I limitatori di Tipo 2 sono costruiti con

Dettagli

Proteggere dai temporali OVR PLUS: la protezione dalle sovratensioni per la casa

Proteggere dai temporali OVR PLUS: la protezione dalle sovratensioni per la casa Proteggere dai temporali : la protezione dalle sovratensioni per la casa Scaricatore di sovratensioni per centralini domestici. è uno scaricatore di sovratensioni autoprotetto per sistemi TT monofase.

Dettagli

Catalogo Generale 2012

Catalogo Generale 2012 nergy ndustrial Solutions atalogo enerale 202 Prodotti per distribuzione di energia pparecchi modulari Linea Modulare Plus nterruttori scatolati nterruttori aperti - Sezionatori ccessori elettrici Quadri

Dettagli

Disgiuntori termici 3131

Disgiuntori termici 3131 Disgiuntori termici 33 Descrizione Combinazione di un disgiuntore unipolare e di un commutatore N/FF a bascula soft-touch. I bilancieri rivestiti in gomma sono disponibili in diversi colori, con diversi

Dettagli

Minicontattori serie BG

Minicontattori serie BG Minicontattori serie BG Planet-SWITCH Planet-DIN Planet-LOGIC electric 100% elettricità electric 100% elettricità La nuova gamma di minicontattori Lovato I minicontattori Serie BG, nati dalla grande esperienza

Dettagli

INTERRUTTORI SALVAMOTORI MAGNETOTERMICI

INTERRUTTORI SALVAMOTORI MAGNETOTERMICI INTERRUTTORI SALVAMOTORI MAGNETOTERMICI Gli interruttori salvamotori magnetotermici LOVATO Electric sono idonei per i nuovi motori ad alti valori di efficienza IE3. INTERRUTTORI SALVAMOTORI MAGNETOTERMICI

Dettagli

SERIE 22 Contattori modulari 25-40 - 63 A

SERIE 22 Contattori modulari 25-40 - 63 A SERIE SERIE Contattore modulare 25 A - 2 contatti arghezza 17.5 mm Apertura contatti NO 3 mm, doppia rottura Bobina e contatti per servizio continuo Bobina AC/DC silenziosa (con varistore di protezione)

Dettagli

SERIE 55 Relè industriale 7-10 A. 2 scambi 10 A

SERIE 55 Relè industriale 7-10 A. 2 scambi 10 A SERIE Relè industriale 7-10 SERIE Relè per impieghi generali Montaggio su circuito stampato.12.13.14 Tipo.12 -- 2 scambi 10 Tipo.13 -- 3 scambi 10 Tipo.14 -- 4 scambi 7 Bobina C o DC Contatti senza Cadmio

Dettagli

RELÈ DIFFERENZIALI serie RDC

RELÈ DIFFERENZIALI serie RDC 125 serie RDC I Relè differenziali della serie RDC sono stati concepiti per soddisfare qualunque applicazione dove sia richiesta una una protezione di guasto verso terra. La sua ampia regolazione di corrente/tempo

Dettagli

Interruttore Scatolato TemBreak2. Benefici per utenti e progettisti

Interruttore Scatolato TemBreak2. Benefici per utenti e progettisti Interruttore Scatolato TemBreak2 Benefici per utenti e progettisti Contenuti 1. L Interruttore Sicuro 2. Norme e Certificati 3. Caratteristiche Uniche 4. Gamma 5. Accessori 6. Installazione 7. Protezione

Dettagli

Prese serie Unika 88 Prese serie Unika con trasformatore SELV 90 Accessori prese serie Unika 91 Prese serie Compact 92 Prese serie Isoblock 93 Prese

Prese serie Unika 88 Prese serie Unika con trasformatore SELV 90 Accessori prese serie Unika 91 Prese serie Compact 92 Prese serie Isoblock 93 Prese Prese serie Unika 88 Prese serie Unika con trasformatore SELV 90 Accessori prese serie Unika 91 Prese serie Compact 92 Prese serie Isoblock 93 Prese serie Isoblock con trasformatore SELV 96 Accessori prese

Dettagli

SERIE RB Relè bistabile 8 A

SERIE RB Relè bistabile 8 A SERIE SERIE Relè bistabile di commando e segnalazione.14 Montaggio su barra 35 mm (EN 60715).22 Base undecal, montaggio su zoccolo 90.21 2 o 4 contatti in scambio Tensione di alimentazione DC Versione

Dettagli

Btdin Interruttore differenziale magnetotermico 4500A fino a 32A (2P)

Btdin Interruttore differenziale magnetotermico 4500A fino a 32A (2P) Sommairio Pagine 1. Descrizione... 2 2. Gamma... 2 3. Dati dimensionali... 2 4. Messa in opera - collegamento... 3 5. Caratteristiche generali... 4-7 6. Conformità e certificazioni... 8 7. Curve caratteristiche...

Dettagli

Moduli per arresto d'emergenza e ripari mobili

Moduli per arresto d'emergenza e ripari mobili Modulo di sicurezza per il controllo dei pulsanti di arresto di emergenza e dei ripari mobili Certificazioni Caratteristiche del dispositivo Uscite a relé a conduzione forzata: 2 contatti di sicurezza

Dettagli

Serie 60 - Relè industriale 6-10 A. Caratteristiche

Serie 60 - Relè industriale 6-10 A. Caratteristiche Serie 60 - Relè industriale 6-10 A Caratteristiche Montaggio ad innesto su zoccolo Relè industriale 10 A 2 o 3 contatti in scambio Contatti senza Cadmio (versione preferita) Bobina AC o DC UL Listing (combinazione

Dettagli

Dati tecnici. Note di sicurezza. Assorbimento In funzione Mantenimento Dimensionamento. 2.5 W alla coppia nominale 0.4 W 6 VA Contatti ausiliari

Dati tecnici. Note di sicurezza. Assorbimento In funzione Mantenimento Dimensionamento. 2.5 W alla coppia nominale 0.4 W 6 VA Contatti ausiliari Scheda ecnica Attuatore rotativo SRA-S Attuatore rotativo per valvola di regolazione a sfera a e vie Coppia Nm ensione nominale AC...4V Comando: On/Off o a punti Contatto ausiliario Dati tecnici Dati elettrici

Dettagli

POWER 2015 SISTEMI DI PROTEZIONE

POWER 2015 SISTEMI DI PROTEZIONE POWER 2015 SISTEMI DI PROTEZIONE Gruppo GEWISS GEWISS è una realtà leader operante a livello internazionale nella produzione di sistemi e componenti per le installazioni elettriche di bassa tensione. Lo

Dettagli

Compact NSX DC Masterpact NW DC

Compact NSX DC Masterpact NW DC Bassa Tensione Compact NSX DC Masterpact NW DC Interruttori in corrente continua da 16 a 4000 A Catalogo 2012-2013 TM Compact NSX e Masterpact NW in corrente continua Un offerta completa in corrente continua

Dettagli

SERIE 34 Relè elettromeccanico per circuito stampato 6 A. Ultra sottile con 1 contatto - 6 A

SERIE 34 Relè elettromeccanico per circuito stampato 6 A. Ultra sottile con 1 contatto - 6 A SERIE Relè elettromeccanico per circuito stampato 6 SERIE Ultra sottile con 1 contatto - 6.51.51-5010 Montaggio su circuito stampato - diretto o su zoccoli da circuito stampato Montaggio su barra 35 mm

Dettagli

Comando e Segnalazione

Comando e Segnalazione Introduzione /2 Interruttori di manovra-sezionatori /3 Interruttori di comando, deviatori e commutatori /4 Elementi ausiliari e sbarre di collegamento /5 Sezionatori sottocarico / Commutatori modulari

Dettagli

Interruttori principali e di emergenza SENTRON LD

Interruttori principali e di emergenza SENTRON LD Interruttori e di emergenza SENTRON LD Descrizione Panoramica polo (conduttore N) morsetto N o PE passante 1 NA + 1 NC Comando rotativo rosso/giallo Comando rotativo nero Mostrina frontale tedesco/inglese

Dettagli

Interruttori a pedale

Interruttori a pedale PS... / PD... Doppio isolamento Custodia in tecnopolimero IP65 Applicazioni Macchine operatrici comandate da interruttori a pedale, come: piegatrici, cesoie, macchine per industria, macchine utensili,

Dettagli

Sensori Magnetici di Sicurezza

Sensori Magnetici di Sicurezza Sensori Magnetici di Sicurezza Sensori Magnetici di Sicurezza - Serie SMP1 Distanza di azionamento 5 mm SMP1AMG Sensori Magnetici di Sicurezza Contatti 1NA + 1NC SMP1A SMP1A K SMP1A 001M 1NA + SMP1A L

Dettagli

SERIE 46 Relè per applicazioni ferroviarie 8-16 A 46.52T 46.61T

SERIE 46 Relè per applicazioni ferroviarie 8-16 A 46.52T 46.61T SERIE Relè per applicazioni ferroviarie 8-16 A SERIE Relè ad innesto Tipo.52T -- 2 scambi 8 A Tipo.61T -- 1 scambio 16 A Conformi alle normative EN 45545-2:2013 (protezione contro fuoco e fumi), EN 61373

Dettagli

Terasaki Italia Srl via Campania, Segrate (MI) Tel Fax

Terasaki Italia Srl via Campania, Segrate (MI) Tel Fax Sovracorrenti Generalità E trattato l impiego degli interruttori magnetotermici modulari (MCBs: Miniature Circuit Breakers) nell edilizia residenziale, intendendo per edifici residenziali quelli che contengono

Dettagli

Pag CONTATTORI TRIPOLARI E QUADRIPOLARI

Pag CONTATTORI TRIPOLARI E QUADRIPOLARI Pag. 1-2 CONTATTORI UNIPOLARI E BIPOLARI Corrente di impiego Ith AC1 (400V): 20A e 32A. Corrente di impiego AC3 (400V): 9A. Ideali per applicazioni domestiche e nel settore terziario. Pag. 1-2 CONTATTORI

Dettagli