1.2 Consideration of the foreseeable misuse Considerazioni sull uso improprio prevedibile

Save this PDF as:
 WORD  PNG  TXT  JPG

Dimensione: px
Iniziare la visualizzazioe della pagina:

Download "1.2 Consideration of the foreseeable misuse Considerazioni sull uso improprio prevedibile"

Transcript

1 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da TECHNICAL REPORT RAPPORTO TECNICO no. MEC Rev. 01 Dated This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. A positive report is necessary but not sufficient for the product certificate issue. Without a valid certificate related to the product, the use of TUV SUD mark is not allowed. E' ammessa soltanto la riproduzione integrale del presente rapporto di prova. Qualsiasi utilizzo a scopo pubblicitario deve essere autorizzato per iscritto. I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova e non sono estendibili ad altri prodotti della normale produzione. Il rapporto di prova con esito positivo costituisce una condizione necessaria ma non sufficiente per l ottenimento della certificazione di prodotto,. In assenza di un certificato di prodotto valido non è consentito l uso del marchio TUV SUD. ZAMET S.P.A Client: Cliente: Manufacturer Produttore Via Torino, Volpiano (TO) Customer code: Contact person: Mr. Giorgio MELANDRI ZAMET S.P.A Via Torino, Volpiano (TO) Customer code: Manufacturing place: Luogo di produzione: Test subject: Prodotto sottoposto a prova: Test specification: Specifiche di prova: Purpose of examination: Scopo della prova: Contact person: Mr. Giorgio MELANDRI As above Come sopra Fixing system for photovoltaic panel. Sistemi di fissaggio per impianti fotovoltaici. PPP 55015B:2011 Test according to the test specification Collaudo effettuato in accordo alle specifiche di prova Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 1 of 15 Gianpaolo MENSA Issue date:

2 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Test result: Risultato della prova: The test results show that the presented product is in compliance with the specified requirements. I risultati dei test dimostrano la conformità del prodotto con i requisiti specifici applicabili. 1 Description of the test subject Descrizione del campione sottoposto a prova Fixing system for photovoltaic panel. Sistemi di fissaggio per impianti fotovoltaici. 1.1 Function Funzione Manufacturer s specification for intended use: Specifiche del costruttore per l uso previsto: Fixing system for photovoltaic panel. Sistemi di fissaggio per impianti fotovoltaici. Manufacturer s specification for predictive misuse: Specifiche del costruttore per l uso improprio Following the user manual with care for product mounting. Seguire attentamente le indicazioni per il montaggio e I consigli dati dal manuale d installazione. 1.2 Consideration of the foreseeable misuse Considerazioni sull uso improprio prevedibile Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis Non applicabile Coperte dalla normativa applicabile Riportate nei seguenti commenti Coperte dall analisi dei rischi allegata Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 2 of 15 Gianpaolo MENSA Issue date:

3 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da 1.4 Appliance identification code Codice di identificazione prodotto Test campaign carried out from ZAMET S.p.A Prove effettuate presso ZAMET S.p.A. 2. Order Ordine Date of Purchase Order, Customer s Reference Data dell ordine, riferimenti del cliente Order number: 8813/2011 Numero ordine: 8813/ Receipt of Test Sample, Location Data ricevimento dei campioni, luogo di ricevimento 2012/01/17_ZAMET S.p.A, Via Torino 109, Volpiano (TO). 2.3 Date of Testing Data delle prove From 2012/03/05 to 2012/03/15. Da 05/03/2012 to 15/03/ Location of Testing Luogo di prova 2012/01/17_ZAMET S.p.A, Via Torino 109, Volpiano (TO). 2.5 Points of Non-compliance or Exceptions of the Test Procedure Punti di non conformità o eccezioni alle specifiche di prova None. Nessuno. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 3 of 15 Gianpaolo MENSA Issue date:

4 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da 3. Test Results Risultati della prova Positive Test Results Risultati di prova positivi The test specifications are met Le specifiche di prova sono soddisfatte. Test carried out on version with step of 1500 mm and inclination of 38. Le prove sono state effettuate sulla versione tipo con passo 1500 mm ed inclinazione di Test according to EN _Wind action on structure. 1.Test in accordo a EN _Azione del vento su strutture. Fw= CsCd x Cf x Qp(Ze) x Aref Where: Dove: CsCd = Structural factor defined as 1/ E' lo structural factor definito pari a 1; Cf = Is the force coefficient for the structure, central zone reference A / E' il force coefficient, la zona identificata come riferimento è la zona centrale (zona A). With these date we have a positive Cf of 1,7 and negative Cf of -1,6; Con questi dati si rileva un Cf positivo di 1,7 ed un Cf negativo di -1,6; Qp(Ze) = Is the peak velocity pressure / E' la pressione della velocità di picco Qp(Ze) defined by / è data da: Ce(Z) x 1/2 x ρ x Vb2 Ce(Z) = Coastal area, category 0 at 3 meters. / Si ricava considerando una zona costiera (cat. 0) a 3 metri di altezza; ρ = Is the air density as 1.25Kg/m 3 / E' la densità dell'aria pari a 1,25 Kg/m 3 ; Vb = Is the wind speed take out from National annex of referrer to wind of 26 m/s. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 4 of 15 Gianpaolo MENSA Issue date:

5 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da E' la velocità del vento presa dall'allegato nazionale alla norma riferito al vento in montagna pari a 26 m/s; So / Quindi: Qp(ze) = 1056,25 N/m 2 Aref = Is the reference area as 1m 2 / è l area di riferimento (per valori in tabella considerata come 1m 2 ) Fw 1796 N / Kg Downward force / Forza che agisce dall'alto verso il basso Positive result Test positivo Fw N / Kg Lifting force / Forza che agisce dal basso verso l'alto Positive result Test positivo Wind speed / velocità vento = 26 m/s. Test refernce area / Area di riferimento per test = 6,4 m 2 Test load / Carico di prova = N / Kg Test load / Carico di prova = N / Kg Set up test / allestimento prova. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 5 of 15 Gianpaolo MENSA Issue date:

6 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Result / Risultato: No breakage has been recorded under the action forces applied like show the pictures below. See note No.1 sotto l azione delle forze applicate il prodotto in configurazione tipo non ha subito danneggiamenti o rotture. Vedi nota n 1. Note No.1: For verify the most unfavorable condition the product has been fixed without 4 (four) screw but only 2 (two) screw for flange. Nota n 1: Al fine di verificare la condizione più s favorevole possibile il prodotto è stato testato fissandolo non con 4 (quattro) punti di fissaggio per flangia bensì con 2 (due) punti di fissaggio per flangia. Downward force / Forza che agisce dall alto verso il basso. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 6 of 15 Gianpaolo MENSA Issue date:

7 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Lifting force / Forza che agisce dal basso verso l alto. Fig.1_Product during test / Prodotto in prova. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 7 of 15 Gianpaolo MENSA Issue date:

8 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.2_ Product during test / Prodotto in prova. Fig.3_ Product during test / Prodotto in prova Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 8 of 15 Gianpaolo MENSA Issue date:

9 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.4_Snow load on panel, elastic deformation / Carico neve su pannello deformazione elastica. Fig.5_Dimensional check on structure component / Analisi dimensionale su componenti. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 9 of 15 Gianpaolo MENSA Issue date:

10 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.6_Details on fixing system / Particolare su sistema di fissaggio. Fig.7_Anchor system between panels / Sistema di ancoraggio fra pannelli. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 10 of 15 Gianpaolo MENSA Issue date:

11 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.8_Panel s fixing system / Sistema di fissaggio pannello. Fig.9_Product after test snow load / Prodotto dopo test carico neve. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 11 of 15 Gianpaolo MENSA Issue date:

12 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.10_Set up test wind load / Allestimento prova carico vento. Fig.11_ Set up test wind load / Allestimento prova carico vento. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 12 of 15 Gianpaolo MENSA Issue date:

13 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da Fig.12_Product after test campaign / Prodotto a fine campagna prove. Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 13 of 15 Gianpaolo MENSA Issue date:

14 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da 3.2 Points of non-compliance according to the test specification Punti di non conformità in accordo alle specifiche di prova None. Nessuno. 4. Remark Commenti The user manual has been examined according to the minimum requirements described in the product standard. The manufacturer is responsible for the accuracy of further particulars as well as of the composition and layout. Le istruzioni per l uso sono state esaminate in accordo ai requisiti minimi descritti negli standard di prodotto. Il costruttore è responsabile dell accuratezza di ulteriori informazioni riportate. 4.1 Remarks to Factory Note per le visite ispettive The assembly of the product has to comply with the documentation (CDF). Before the implementation of safety relevant modifications to the product into the ongoing production the product must be retested for acceptance. The results must be implemented to the documentation and if necessary the certificate must be updated. The factory inspections will be performed once a year. L assemblaggio del prodotto deve essere conforme alla documentazione (CDF) Prima di implementare in produzione modifiche rilevanti per la sicurezza, il prodotto deve essere ritestato, ai fini dell accettazione di tali modifiche. I risultati devono essere documentati e, se necessario, il certificato deve essere riemesso. Le visite ispettive al sito produttivo verranno effettuate una volta all anno. 5. Documentation Documentazione Petent no. / brevetto n TO2011A000106; Petent no. / brevetto n TO2011A000107; Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 14 of 15 Gianpaolo MENSA Issue date:

15 TÜV Italia PS-ENEis accredited / recognised by TÜV Italia PS-ENE è accreditato / riconosciuto da 6. Summary Riassunto None. TÜV Italia srl Mechanical Safety Dept. Engineer: Technical Report checked: (Gianpaolo MENSA) (Daniele MAZZEI) Code 12/ Form: ITA_F_09.02 (Rev 8 March 12, 2012) Phone: Document name: MEC Technical report no. : MEC Revision: 01 Page 15 of 15 Gianpaolo MENSA Issue date:

16 RAPPORTO DI PROVA TEST REPORT Titolo (Title): SALT MIST TEST on SUPPORTS for PHOTOVOLTAIC PANELS Richiedente (Customer): - Ente/Società (Dept./Firm): ZAMET S.P.A - Sig.(Mr): Giorgio Melandri - Indirizzo (Address): Via Torino N VOLPIANO ( TO ) Modulo Richiesta Prova n.: Rapporto inviato a: Test Requesting Form no.: Report sent to: 028_12_STAMB Sig. Giorgio Melandri Data ricevimento campioni: 2012/02/03 Data esecuzione prove: from 2012/12/03 Date of test samples receipt: Date of test execution: to 2012/02/14 Località esecuzione prove (se diversa dal pié di pagina): Presenti alle prove: / Site of test execution (if different from the address in the footer): Witness to the test: I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. The test results contained in this Test report relate to the tested samples only. E' ammessa la riproduzione integrale del presente Rapporto di prova da parte del Richiedente; la riproduzione parziale dev'essere autorizzata per iscritto dal Laboratorio. The integral reproduction of the present Test report is allowed; the partial reproduction must be authorized in writing by the Lab. Page 1 of 30

17 1. SETUP DI PROVA TEST SETUP 1.1. IDENTIFICAZIONE CAMPIONE SAMPLE IDENTIFICATION - Prodotto/materiale sottoposto a prova: Supports Product/material subjected to test: - Descrizione: N 21 Supports for photovoltai c panels Description: - Livello (Prodotto di serie, prototipo, ecc.): Prototype Level (Series product, prototype, etc.): - N Matricola: / Part number: - Codice di identificazione: C C Identification code: 1.2. DISPOSITIVI AUSILIARI AUXILIARY DEVICES None CONFIGURAZIONE DI PROVA TEST CONFIGURATION During the tests the Es.U.T were not in operating mode SISTEMA DIAGNOSTICO DIAGNOSTIC SYSTEM Visual inspection of the samples at the start of the test after 48h, 96h and at the end of the test ( 240 h ). Page 2 of 30

18 2. ELENCO DELLE PROVE TEST LIST - SALT MIST TEST 3. METODO DI PROVA TEST METHOD X Normalizzato - Norma di riferimento: ISO 9227:2006; EN1670:2008 Standardized - Reference Standard Eventuali scostamenti, aggiunte o limitazioni Possible differences, additions or limitations: Interno - Descrizione: Internal Description: 4. APPARECCHIATURE UTILIZZATE TEST EQUIPMENT USED - Salt Fog Chamber ERICHSEN 610/1000E s/n CONDIZIONI AMBIENTALI ENVIRONMENTAL CONDITIONS Temperature = 22 C Relative Humidity = 49% Atmospheric Pressure = 998 mbar 6. INCERTEZZA DI MISURA MEASUREMENT UNCERTAINTY Expanded uncertainty T= ±3 C U.R. =±5 % Corresponding to a confidence level of about 95% 7. PIANO DI CAMPIONAMENTO SAMPLING PLAN Samples selected by the customer Page 3 of 30

19 8. RISULTATI DELLE PROVE E/O MISURE TEST AND / OR MEASUREMENT RESULTS 8.1 SALT MIST TEST The samples under test was introduced into a Fog Chamber Apparatus, capable to spray a Salt Solution (5%) prepared in compliance with ISO 9227:2006 standard ( 5 parts by weight of salt in 95 parts by weight of distilled water ). I campioni sotto test sono stati introdotti nella camera di nebbia salina in grado di nebulizzare una soluzione salina al ( 5% ) in accord con la ISO 9227:2006 ( 5 parti in peso di sale in 95 parti in peso di acqua demineralizzata ) It was carried out a cycle of 12 hours at the room temperature of 25 C. During this cycle the solution was collected into rain gauges. E stato effettuato un ciclo a vuoto di 12 ore a temperature ambiente di 25 C. Durante questo ciclo la soluzione è stata raccolta in dei pluviometri. The solution collected in each rain gauge must be between 1 ml and 2 ml per hour and the PH value between 6.5 and 7.2 at a temperature of 20 C La soluzione raccolta in ogni pluviometro deve essere tra 1 ml e 2 ml per ora e il valore del PH compreso tra 6.5 e 7.2 alla temperatura di 20 C The temperature of Salt Fog Chamber Apparatus was maintained at +35 C. La temperature della camera di nebbia salina è stata mantenuta a +35 C Test duration: 240 total hours Durata del test: 240 ore totali ID Rain gauge Amount collected ml/h 40_PLU 17.4 ml _PLU ml 1.58 PH value: 6.8 EVALUATION METHOD in according to EN 1670:2008 Page 4 of 30

20 Results: N Sample Code Material 48 hours (degree ) 96 hours (degree ) 240 hours ( degree ) 1 T DD11 UNI EN 10111, galvanized T UNI EN (AISI 430) E UNI EN (AISI 430) A E UNI EN (AISI 304) B T UNI EN (AISI 304) E UNI EN (AISI 316L) Page 5 of 30

21 8 / MAGNELIS T UNI EN (AISI 316L) T bulloneria UNI EN (AISI 430) Geomet 321 A E bulloneria UNI EN (AISI 430) Geomet 321 A E bulloneria UNI EN (AISI 430) Geomet 321 A e DAFNElac FXC/L T bulloneria UNI EN (AISI 430) Geomet 321 A E bulloneria E bulloneria UNI EN (AISI 430) Geomet 321 A UNI EN (AISI 430) Geomet 321 A E bulloneria UNI EN (AISI 430) E bulloneria UNI EN (AISI 430) Geomet 321 A E bulloneria UNI EN (AISI 430) Geomet 321 A E bulloneria UNI EN (AISI 430) Fe/Zn 12 IV S FIAT E bulloneria UNI EN (AISI 430) UNI EN (AISI 301) Page 6 of 30

22 21 E UNI EN (AISI 304) E UNI EN (AISI 304) NOTE REMARKS The configuration has been supplied by the customer. La configurazione e stata fornita dal cliente The customer is responsible for the paragraph 1.1 reported data and for the configuration of the tested EUT. Il cliente e responsabile per i dati riportati al paragrafo 1.1 ( Identificazione campione ) e per la configurazione dell EUT testato The sample under test was returned to the customer. ll campione testato è stato restituito al cliente 10. APPENDICE (documentazione fotografica del setup di prova / allegati) APPENDIX (photographic report test setup / attachments) Summary for photo documentation. N Sample Code Material 48 hours ( degree ) 96 hours ( degree ) 240 hours ( degree ) 1 T DD11 UNI EN 10111, galvanized photo 1 photo 2 photo 3 2 T UNI EN (AISI 430) photo 4 photo 5 photo 6 3 E UNI EN (AISI 430) photo 7 photo 8 photo 9 4A E UNI EN (AISI 304) photo 10 photo 11 photo 12 Page 7 of 30

23 4B T UNI EN (AISI 304) photo 13 photo 14 photo 15 6 E UNI EN (AISI 316L) photo 16 photo 17 photo 18 8 / MAGNELIS photo 19 photo 20 photo 21 9 T UNI EN (AISI 316L) photo 22 photo 23 photo T bulloneria UNI EN (AISI 430) Geomet 321 A photo 25 photo 26 photo E bulloneria UNI EN (AISI 430) Geomet 321 A photo 28 photo 29 photo E bulloneria UNI EN (AISI 430) Geomet 321 A e DAFNElac FXC/L photo 31 photo 32 photo T bulloneria UNI EN (AISI 430) Geomet 321 A photo 34 photo 35 photo E bulloneria UNI EN (AISI 430) Geomet 321 A photo 37 photo 38 photo E bulloneria UNI EN (AISI 430) Geomet 321 A photo 40 photo 41 photo E bulloneria UNI EN (AISI 430) photo 43 photo 44 photo E bulloneria UNI EN (AISI 430) Geomet 321 A photo 46 photo 47 photo 48 Page 8 of 30

24 18 E bulloneria UNI EN (AISI 430) Geomet 321 A photo 49 photo 50 photo E bulloneria UNI EN (AISI 430) Fe/Zn 12 IV S FIAT photo 52 photo 53 photo E bulloneria UNI EN (AISI 430) UNI EN (AISI 301) photo 55 photo 56 photo E UNI EN (AISI 304) photo 58 photo 59 photo E UNI EN (AISI 304) photo 61 photo 62 photo 63 Page 9 of 30

25 Photo 1 Photo 2 Photo 3 Page 10 of 30

26 Photo 4 Photo 5 Photo 6 Page 11 of 30

27 Photo 7 Photo 8 Photo 9 Page 12 of 30

28 Photo 10 Photo 11 Photo 12 Page 13 of 30

29 Photo 13 Photo 14 Photo 15 Page 14 of 30

30 Photo 16 Photo 17 Photo 18 Page 15 of 30

31 Photo 19 Photo 20 Photo 21 Page 16 of 30

32 Photo 22 Photo 23 Photo 24 Page 17 of 30

33 Photo 25 Photo 26 Photo 27 Page 18 of 30

34 Photo 28 Photo 29 Photo 30 Page 19 of 30

35 Photo 31 Photo 32 Photo 33 Page 20 of 30

36 Photo 34 Photo 35 Photo 36 Page 21 of 30

37 Photo 37 Photo 38 Photo 39 Page 22 of 30

38 Photo 40 Photo 41 Photo 42 Page 23 of 30

39 Photo 43 Photo 44 Photo 45 Page 24 of 30

40 Photo 46 Photo 47 Photo 48 Page 25 of 30

41 Photo 49 Photo 50 Photo 51 Page 26 of 30

42 Photo 52 Photo 53 Photo 54 Page 27 of 30

43 Photo 55 Photo 56 Photo 57 Page 28 of 30

44 Photo 58 Photo 59 Photo 60 Page 29 of 30

45 Photo 61 Photo 62 Photo 63 Page 30 of 30

no. SIC04053.03 Rev. 00 Dated 2008.10.02

no. SIC04053.03 Rev. 00 Dated 2008.10.02 TECHNICAL REPORT RAPPORTO TECNICO no. SIC04053.03 Rev. 00 Dated 2008.10.02 This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is

Dettagli

RAPPORTO DI PROVA TEST REPORT

RAPPORTO DI PROVA TEST REPORT RAPPORTO DI PROVA TEST REPORT Titolo (Title): Electro Magnetic Emission Tests on SP40 plus Richiedente (Customer): - Ente/Società (Dept./Firm): Compuprint S.p.A. - Sig.(Mr.): Daniele Zanino - Indirizzo

Dettagli

RAPPORTO DI PROVA TEST REPORT. KONTROLDRY mod. 20. KONTROLDRY mod. 20

RAPPORTO DI PROVA TEST REPORT. KONTROLDRY mod. 20. KONTROLDRY mod. 20 RAPPORTO DI PROVA TEST REPORT Verifica dei campi magnetici ed elettrici non ionizzanti su KONTROLDRY mod. 20 EMF tests on KONTROLDRY mod. 20 Richiedente (Customer): - Ente/Società (Dept./Firm): S.K.M.

Dettagli

KalibraDRY modello N 4.0

KalibraDRY modello N 4.0 RAPPORTO DI PROVA TEST REPORT Titolo (Title): Misura di emissioni elettromagnetiche su: KalibraDRY modello N 4.0 Richiedente (Customer): - Ente/Società (Dept./Firm): S.K.M. s.r.l. (Soluzioni Kalibrate

Dettagli

RAPPORTO DI PROVA TEST REPORT

RAPPORTO DI PROVA TEST REPORT RAPPORTO DI PROVA TEST REPORT Titolo (Title): VIBRATION TEST ON FRIGOBOX T0056 Richiedente (Customer): Ente/Società (Dept./Firm): Sig. (Mr.): Indirizzo (Address): EUROENGEL S.R.L. C. SCAMARDELLA Via Ferrini,

Dettagli

Alimentatore modello PS10-BB

Alimentatore modello PS10-BB RAPPORTO DI PROVA TEST REPORT Titolo (Title): Rilievi di radio-interferenza su: Electro Magnetic Emission Tests on Alimentatore modello PS10-BB Richiedente (Customer): - Ente/Società (Dept./Firm): CIAR

Dettagli

Deles Imballaggi Speciali s.r.l. rapporto test caduta e trasportabilità 1

Deles Imballaggi Speciali s.r.l. rapporto test caduta e trasportabilità 1 RAPPORTO DI PROVA TEST REPORT KI52637A-AUSILIA-GENICO PROVA DI CADUTE LIBERE Richiedente (Customer ): Ente/Società (Company ): Sig. : AUSILIA Fabrizio Chierici Indirizzo (Address ): Modulo richiesta prova

Dettagli

RAPPORTO DI PROVA TEST REPORT PROVE DI VERIFICA DI DECADIMENTO SECONDO DIN SU VERNICE FOTOLUMINESCENTE

RAPPORTO DI PROVA TEST REPORT PROVE DI VERIFICA DI DECADIMENTO SECONDO DIN SU VERNICE FOTOLUMINESCENTE RAPPORTO DI PROVA TEST REPORT PROVE DI VERIFICA DI DECADIMENTO SECONDO DIN 67510 SU VERNICE FOTOLUMINESCENTE Test according to DIN 67510 on Phosphorescent pigments and products MAGIC LIGHT K 100 Richiedente

Dettagli

COSTRUZIONI FISICA DELLE COSTRUZIONI

COSTRUZIONI FISICA DELLE COSTRUZIONI COSTRUZIONI FISICA DELLE COSTRUZIONI 1/6 FIREBOLT A2 mod. Standard varnished / galvanized / AISI 316 FIREBOLT A2 mod. STEALTH varnished / galvanized / AISI 316 FIREBOLT A varnished / galvanized / AISI

Dettagli

TEST REPORT INDICE - INDEX

TEST REPORT INDICE - INDEX Test Report Number: 10/11/2015 Sesto San Giovanni (MI) Data Emissione - Issuing date Luogo Emissione - Issuing place Verifica della conformità al capitolato prove di KIDS P.A. S.r.l secondo EN 12266-1:2012

Dettagli

RAPPORTO DI PROVA TEST REPORT DETERMINAZIONE DELLE PROPRIETA ANTISCIVOLO di piatto doccia finitura morbida ecocresp

RAPPORTO DI PROVA TEST REPORT DETERMINAZIONE DELLE PROPRIETA ANTISCIVOLO di piatto doccia finitura morbida ecocresp RAPPORTO DI PROVA TEST REPORT DETERMINAZIONE DELLE PROPRIETA ANTISCIVOLO di piatto doccia finitura morbida ecocresp Determination of the anti-slip properties of shower tray soft finish ecocresp Richiedente

Dettagli

SMART PIU' -28/112 9 greche POLYPIU'-PLAST S.R.L. VIA DELLE INDUSTRIE, 4 21040 GORNATE OLONA (VA)

SMART PIU' -28/112 9 greche POLYPIU'-PLAST S.R.L. VIA DELLE INDUSTRIE, 4 21040 GORNATE OLONA (VA) COSTRUZIONI FISICA DELLE COSTRUZIONI 1/7 SMART PIU' -28/112 9 greche POLYPIU'-PLAST S.R.L. VIA DELLE INDUSTRIE, 4 21040 GORNATE OLONA (VA) Urto con corpo molle secondo p.to 5.4.4.2 EN 14963:2006 Impact

Dettagli

KontrolDRY mod.10; KontrolDRY mod.20

KontrolDRY mod.10; KontrolDRY mod.20 TÜV Italia S-EE is accredited / recognised by TÜV Italia S-EE è accreditato / riconosciuto da RAORTO DI ROVA TEST REORT Titolo (Title): E 60335-1 Sicurezza degli Apparecchi Elettrici d uso domestico e

Dettagli

UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998

UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998 COSTRUZIONI FISICA TECNICA/ACUSTICA 1/6 ECOstrong Slalom Via Ernesto Rossi, 69 20862 Arcore (MB) UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998 Slalom Capo Laboratorio Laboratory Head 2/6 DATI GENERALI /

Dettagli

1. Domanda di certificazione da riportare su carta intestata del fabbricante che richiede la certificazione / Certification request To report on

1. Domanda di certificazione da riportare su carta intestata del fabbricante che richiede la certificazione / Certification request To report on 1. Domanda di certificazione da riportare su carta intestata del fabbricante che richiede la certificazione / Certification request To report on LETTERHEAD PAPER of the applicant 2. Elenco documenti che

Dettagli

DNV BUSINESS ASSURANCE

DNV BUSINESS ASSURANCE DNV BUSINESS ASSURANCE CERTIFICATO CE DI TIPO EC TYPE-EXAMINATION CERTIFICATE Certificato No. / Certificate No. 2666-2013-CE-ITA-ACCREDIA Questo certificato è di 5 pagine / This certificate consists of

Dettagli

TUBO PIUMA 100 Presa d aria silenziata per fori di ventilazione nelle facciate degli edifici Air intake silencer for air intakes of building façades

TUBO PIUMA 100 Presa d aria silenziata per fori di ventilazione nelle facciate degli edifici Air intake silencer for air intakes of building façades ISOLAMENTI ACUSTICI DEI SILENZIATORI ACUSTICI DI FACCIATA PER ENTRATA ED ESPULSIONE ARIA CERTIFICATI DAL CSI Modello: TUBO PIUMA 100 L = 300 mm L = 400 mm Dn,e,w = 41 db Dn,e,w = 47 db L Passaggio aria

Dettagli

Costruzioni Constructions. Acustica Acoustics 0109/DC/ACU/10 26/07/2010

Costruzioni Constructions. Acustica Acoustics 0109/DC/ACU/10 26/07/2010 Costruzioni Constructions Acustica Acoustics 0109/DC/ACU/10 26/07/2010 1 VAWA panel partition + plasterboard lining Veneziani Acell S.r.l. Via delle Groane 126 I-20024 Garbagnate Milanese (MI) UNI EN ISO

Dettagli

UNI EN ISO 12944-6. Corrosion protection of steel structures by protective paint systems. Laboratory performance test for

UNI EN ISO 12944-6. Corrosion protection of steel structures by protective paint systems. Laboratory performance test for via di Marmiceto, 6/C-56016 Ospeetto PISA P.IVA 01115340505 CCIAA Pi 101169 Report n 2050451/5 UNI EN ISO 12944-6 Corrosion protection of steel structures by protective paint systems Laboratory performance

Dettagli

REPORT AUDIT DI DOSE PER STERILIZZAZIONE RAGGI BETA ELECTRON BEAM STERILIZATION VALIDATION REPORT

REPORT AUDIT DI DOSE PER STERILIZZAZIONE RAGGI BETA ELECTRON BEAM STERILIZATION VALIDATION REPORT PROGRAMMA DI ASSICURAZIONE QUALITÀ QUALITY ASSURANCE PROGRAMM PROCEDURA DI QUALITÀ PQ 008 QUALITY PROCEDURE Pag. 1 di 6 REPORT AUDIT DI DOSE PER STERILIZZAZIONE RAGGI BETA ELECTRON BEAM STERILIZATION VALIDATION

Dettagli

CERTIFICATO CE DI CONFORMITÀ < PRODOTTO(I) (2) >

CERTIFICATO CE DI CONFORMITÀ < PRODOTTO(I) (2) > Allegato 1: Facsimile di Certificato per s.a.c. 1+ < Logo dell Organismo di certificazione > > CERTIFICATO CE DI CONFORMITÀ In conformità alla Direttiva

Dettagli

DNV-MUNO 0496.CPD.10/4839

DNV-MUNO 0496.CPD.10/4839 10156 TORINO (ITALY) 21, Via Cuorgnè Telefono +39.011.22.22.225 Fax +39.011.22.22.226 e-mail: info@modulouno.it sito: www.modulouno.it RAPPORTO DI PROVA N Richiedente Customer ALUFON S.r.l. Via E. Mattei,

Dettagli

M/S CERAMICA SCARABEO Località Pian del Trullo 01034 Fabrica di Roma (VT), ITALY. 01034 Fabrica di Roma (VT), ITALY. C. A. Sig.

M/S CERAMICA SCARABEO Località Pian del Trullo 01034 Fabrica di Roma (VT), ITALY. 01034 Fabrica di Roma (VT), ITALY. C. A. Sig. M/S C. A. Sig. Calisti Giampaolo RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 65d/2013 in accordo con la norma UNI EN 14688 sul lavabo LUNA TECHNOLOGIAL LABORATORY TEST REPORT N 65d/2013 in compliance

Dettagli

M/S AMARU' GIOVANNI VIA S. ERASMO snc 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY

M/S AMARU' GIOVANNI VIA S. ERASMO snc 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY M/S 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 49/2012 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 49/2012 In compliance

Dettagli

COSTRUZIONI CONSTRUCTIONS REAZIONE REACTION 0247/DC/REA/10_1 14.04.2010. Product Name. Elastomeric foam insulation

COSTRUZIONI CONSTRUCTIONS REAZIONE REACTION 0247/DC/REA/10_1 14.04.2010. Product Name. Elastomeric foam insulation COSTRUZIONI CONSTRUCTIONS REAZIONE REACTION 0247/DC/REA/10_1 14.04.2010 1 Nome commerciale...: Product Name Descrizione / Description...: K-Flex ST Isoante elastomerico espanso Elastomeric foam insulation

Dettagli

RAPPORTO TECNICO TECHNICAL REPORT n. 211450-1

RAPPORTO TECNICO TECHNICAL REPORT n. 211450-1 n. 2450- Via Carducci 25 Edificio 23 Tel.: +39 02 2430. Fax: +39 02 2430.396 Commessa TÜV Italia TÜV Italia job n. Oggetto Object 2450 Committente Customer Industrie Polieco MPB Srl Via E. Mattei, 49 25046

Dettagli

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0614\DC\REA\12_5

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0614\DC\REA\12_5 RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 014\DC\REA\12_5 Rapporto di classificazione di reazione al fuoco del prodotto : Reaction to fire classification report of product 4W Descrizione : Description

Dettagli

AGED WOOD MRK

AGED WOOD MRK MRK 010-0717 AGED WOOD TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante speciali

Dettagli

PINO SOVRANO MRK

PINO SOVRANO MRK MRK 010-0724 PINO SOVRANO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante speciali

Dettagli

BAMBOO e ZEBRANO per ESTERNO MRK

BAMBOO e ZEBRANO per ESTERNO MRK MRK-010-0564 BAMBOO e ZEBRANO per ESTERNO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco

Dettagli

OLIVO e LEGNI GRIGI per ESTERNO MRK

OLIVO e LEGNI GRIGI per ESTERNO MRK MRK-010-0565 OLIVO e LEGNI GRIGI per ESTERNO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco

Dettagli

Dr. Francesco Bitti. The purpose of the test is to determine if there s a weakening of tensile force on Taltos specimens after aging.

Dr. Francesco Bitti. The purpose of the test is to determine if there s a weakening of tensile force on Taltos specimens after aging. Henkel Technologies ASG Technical Customer Service Date 09/07/2009 Customer Taltos srl Address Via Della Repubblica, 2 Location Inverso Pinasca - TO Attention to Dr. Francesco Bitti Sales Engineer Dr.

Dettagli

MIRROR FOR OUTDOOR MRK

MIRROR FOR OUTDOOR MRK MRK 010-0685 MIRROR FOR OUTDOOR ESPOSIZIONE NATURALE IN FLORIDA: Esposizione naturale Le esposizioni naturali vengono condotte in Florida presso il sito espositivo della Atlas Weathering Service; il sud

Dettagli

- RAPPORTO DI PROVA - PER GRANDI IMBALLAGGI DESTINATI AL TRASPORTO DI MERCI PERICOLOSE

- RAPPORTO DI PROVA - PER GRANDI IMBALLAGGI DESTINATI AL TRASPORTO DI MERCI PERICOLOSE Allegato 3 (Decreto Dirigenziale n. 842 del 21. 07.2015) - RAPPORTO DI PROVA - PER GRANDI IMBALLAGGI DESTINATI AL TRASPORTO DI MERCI PERICOLOSE (articolo 32, comma 5, D.P.R. 6 giugno 2005, n. 134) - TEST

Dettagli

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT) M/S RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 25/2014 in accordo con la norma UNI EN 14688 on lavabi BUTTERFLY TECHNOLOGIAL LABORATORY TEST REPORT N 25/2014 in compliance with the norm UNI EN 14688

Dettagli

QUALITAL. Purpose of the document. Scopo del documento. Scheda Tecnica

QUALITAL. Purpose of the document. Scopo del documento. Scheda Tecnica Via privata Ragni 13/15 28062 Cameri (NO) Tel.: 0321-51.05.78 fax: 0321-51.79.37 e-mail: qualital@qualital.org - web-site: www.qualital.org ISTITUTO DI CERTIFICAZIONE INDUSTRIALE DELL ALLUMINIO N 1 M a

Dettagli

Spett.le M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

Spett.le M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT) Spett.le M/S RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 52a/08 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 52a/08 In compliance with the norm UNI EN 14688 RICHIESTO

Dettagli

We take care of your buildings

We take care of your buildings We take care of your buildings Che cos è il Building Management Il Building Management è una disciplina di derivazione anglosassone, che individua un edificio come un entità che necessita di un insieme

Dettagli

ELCART. Manuale di istruzioni/scheda tecnica SPECIFICATION

ELCART. Manuale di istruzioni/scheda tecnica SPECIFICATION PAGINA 1 DI 7 SPECIFICATION Customer : ELCART Applied To : Product Name : Piezo Buzzer Model Name : : Compliance with ROHS PAGINA 2 DI 7 2/7 CONTENTS 1. Scope 2. General 3. Maximum Rating 4. Electrical

Dettagli

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY M/S 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 48/2012 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 48/2012 In compliance

Dettagli

Costruzioni Constructions. Acustica Acoustics 0092/DC/ACU/10 04/06/2010 K-FONIK GK

Costruzioni Constructions. Acustica Acoustics 0092/DC/ACU/10 04/06/2010 K-FONIK GK Costruzioni Constructions Acustica Acoustics 0092/DC/ACU/10 04/06/2010 1 L Isolante K-Flex S.r.l. Via Leonardo da Vinci, 36 I-20040 Roncello (MI) UNI EN ISO 140-3 :2006 UNI EN ISO 717-1 :2007 Cliente Client

Dettagli

CERTIFICATO DI CONFORMITA' Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07

CERTIFICATO DI CONFORMITA' Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 AZIENDA AGRICOLA SAN DOMENICO DI RUBINO MICHELE & C. SNC VIA RUTIGLIANO, 12 CERTIFICATO DI CONFORMITA' IT BIO 006 P318 10.116 E' CONFORME AI REQUISITI DEL PRODOTTO BIOLOGICO Reg. CE 834/07 E CE 889/08

Dettagli

Quality Certificates

Quality Certificates Quality Certificates Le più importanti certificazioni aziendali, di processo e di prodotto, a testimonianza del nostro costante impegno ed elevato livello di competenze. Qualità * certificata * Certified

Dettagli

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no.

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no. Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no. 327/2011 In base alla direttiva ErP e al regolamento UE n. 327/2011, si impone

Dettagli

CERTIFICAZIONE CAMERA DI COMMERCIO ROMA CERTIFICAZIONE UNI EN ISO 9001:2008 RTIFICAT ZERTIFIKAT CERTIDÃO SERTIFIKA CERTIFICATO CERTIFICADO CERTIFICATE CE ACCERTA Sede Legale: Head Office: Sede(i) Operativa(e):

Dettagli

CERTIFICATO C E R T I F I C A T E Certificato No.: Certificate No.: Nome ed indirizzo del richiedente: Name and Address of the certificate holder: Data della domanda: Date of submission: TÜV IT 14 MAC

Dettagli

Dichiarazione di conformità alle prescrizioni alla Norma CEI 0-21

Dichiarazione di conformità alle prescrizioni alla Norma CEI 0-21 NOME ORGANISMO CERTIFICATORE: OGGETTO: Bureau Veritas Consumer Products Services Germany GmbH Businesspark A96 86842 Türkheim Germany + 49 (0) 40 740 41 0 cps-tuerkheim@de.bureauveritas.com Organismo di

Dettagli

UNI EN ISO 354 :2003 UNI EN ISO :1998

UNI EN ISO 354 :2003 UNI EN ISO :1998 COSTRUZIONI FISICA TECNICA/ACUSTICA 1/6 ECOdesk Slalom Via Ernesto Rossi, 69 20862 Arcore (MB) UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998 Slalom Capo Laboratorio Laboratory Head 2/6 DATI GENERALI / GENERAL

Dettagli

Documento EMC S.r.l. N 0402/2007

Documento EMC S.r.l. N 0402/2007 LABORATORIO DI COMPATIBILITA' ELETTROMAGNETICA Via Greto di Cornigliano 6r, 16152 GENOVA Tel. 010 6017006 Fax 010 6017025 EMC TEST REPORT RAPPORTO DI PROVA EMC Documento EMC S.r.l. N 0402/2007 on su GUAINA

Dettagli

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY M/S 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 47b/2012 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 47b/2012 In compliance

Dettagli

N./No. 0474-CPR-0566. Aggregati per calcestruzzo / Aggregates for concrete. IMPRESA MILESI GEOM. SERGIO S.R.L. Via Molinara, 6-24060 Gorlago (BG)

N./No. 0474-CPR-0566. Aggregati per calcestruzzo / Aggregates for concrete. IMPRESA MILESI GEOM. SERGIO S.R.L. Via Molinara, 6-24060 Gorlago (BG) CERTIFICATO DI CONFORMITÀ DEL CONTROLLO DELLA PRODUZIONE IN FABBRICA / CERTIFICATE OF CONFORMITY OF THE FACTORY PRODUCTION CONTROL N./No. 0474-CPR-0566 In conformità al Regolamento N. 305/2011/EU del Parlamento

Dettagli

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas. centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00

Dettagli

Ingegneria del Software Testing. Corso di Ingegneria del Software Anno Accademico 2012/2013

Ingegneria del Software Testing. Corso di Ingegneria del Software Anno Accademico 2012/2013 Ingegneria del Software Testing Corso di Ingegneria del Software Anno Accademico 2012/2013 1 Definizione IEEE Software testing is the process of analyzing a software item to detect the differences between

Dettagli

componenti per Magazzini dinamici components for Material handling

componenti per Magazzini dinamici components for Material handling componenti per Magazzini dinamici components for Material handling Dispositivo separatore Separator System 294-295 296-298 Ruote deceleranti Brake wheels 300-303 Rulli deceleranti tipo 80 Type 80 brake

Dettagli

Redazione Approvazione Autorizzazione all emissione Entrata in vigore. Il Direttore Generale 2015-07-16

Redazione Approvazione Autorizzazione all emissione Entrata in vigore. Il Direttore Generale 2015-07-16 Titolo/Title Elenco norme e documenti di riferimento per l'accreditamento degli Organismi di Verifica delle emissioni di gas ad effetto serra List of reference standards and documents for the accreditation

Dettagli

DICHIARAZIONE DI RESPONSABILITÀ

DICHIARAZIONE DI RESPONSABILITÀ - 0MNSWK0082LUA - - ITALIANO - DICHIARAZIONE DI RESPONSABILITÀ Il produttore non accetta responsabilità per la perdita di dati, produttività, dispositivi o qualunque altro danno o costo associato (diretto

Dettagli

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT), ITALY

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT), ITALY M/S 01034 Fabrica di Roma (VT), ITALY RAPPORTO TECNOLOGICO n 21/2014 IN ACCORDO CON LA NORMA UNI EN 997/2012 su vaso sospeso serie BUTTERFLY, con scarico a parete. TECHNOLOGIAL LABORATORY TEST REPORT N

Dettagli

FLORIM CERAMICHE SPA Via Canaletto, 24 41042 Fiorano Modenese (MO)

FLORIM CERAMICHE SPA Via Canaletto, 24 41042 Fiorano Modenese (MO) FOOD PACKAGING MATERIALS MATERIALI 0077\FPM\MATs\14 07/02/2014 1 TEST SYSTEM SLIM/4+ ( MULTILAYER WITH FINISH OF CERAMIC PORCELAIN GRESS + FLEXIBLE FOAM FLESSIBILE BASED ON A CLOSED CELL POLYETHYLENE )

Dettagli

Software Sirius Lite 2

Software Sirius Lite 2 Software Sirius Lite 2 Il software Sirius Lite 2 gestisce la configurazione dei data logger, la visualizzazione in tempo reale degli allarmi sui logger, la visualizzazione della tabella dati e del multigrafico

Dettagli

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: lab@catas. centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00

Dettagli

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 S'ATRA SARDIGNA SOC. COOP. A.R.L.

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 S'ATRA SARDIGNA SOC. COOP. A.R.L. Numero identificativo documento giustificativo N reference of Documentary evidence 2014/00011 Numero identificativo N Reference 00104 del 17/09/2014 E' CONFORME AI REQUISITI DEL PRODOTTO BIOLOGICO Reg.

Dettagli

FOTOVOLTAICO E INCOMBUSTIBILITA : PANNELLI ZEROKLASS ROOF

FOTOVOLTAICO E INCOMBUSTIBILITA : PANNELLI ZEROKLASS ROOF FOTOVOLTAICO E INCOMBUSTIBILITA : PANNELLI ZEROKLASS ROOF I recenti DPR 151/11 Regolamento di semplificazione dei procedimenti di prevenzione incendi e Circolare 1324 del 07/02/2012 Guida per l installazione

Dettagli

CONTROLLO ANALITICO DELLA COMPOSIZIONE E DEI REQUISITI DI PUREZZA DI CARTE E CARTONI DESTINATI A VENIRE IN CONTATTO CON GLI ALIMENTI

CONTROLLO ANALITICO DELLA COMPOSIZIONE E DEI REQUISITI DI PUREZZA DI CARTE E CARTONI DESTINATI A VENIRE IN CONTATTO CON GLI ALIMENTI Richiedente: IBEMA COMPANHIA BRASILEIRA DE PAPEL Riferimento: Sig. Murilo A. C. B. Belleza Richiesta: del 14 aprile 2005 Data arrivo campioni: 27 aprile 2005 Data analisi: inizio 2 maggio 2005 Rapporto

Dettagli

N 1 alla versione bilingue (italiano-inglese) NORMA UNI EN ISO 9001 (novembre 2008) Sistemi di gestione per la qualità - Requisiti.

N 1 alla versione bilingue (italiano-inglese) NORMA UNI EN ISO 9001 (novembre 2008) Sistemi di gestione per la qualità - Requisiti. ERRATA CORRIGE N 1 alla versione bilingue (italiano-inglese) DEL 31 luglio 2009 NORMA UNI EN ISO 9001 (novembre 2008) TITOLO Sistemi di gestione per la qualità - Requisiti Punto della norma Pagina Oggetto

Dettagli

Misure di.. FORZA. P = F v

Misure di.. FORZA. P = F v Misure di.. FORZA In FISICA prodotto di una massa per una F = m a accelerazione In FISIOLOGIA capacità di vincere una resistenza o di opporsi ad essa attraverso una contrazione muscolare POTENZA P = F

Dettagli

Requisiti di sicurezza e affidabilità del prodotto Safety requirements and reliability of the product

Requisiti di sicurezza e affidabilità del prodotto Safety requirements and reliability of the product Requisiti di sicurezza e affidabilità del prodotto Safety requirements and reliability of the product Mercantini ha fondato la sua filosofia produttiva sulla qualità, puntando all eccellenza in ogni settore

Dettagli

su efficienza ed etichettatura dei prodotti ErP e Labelling - guida ai regolamenti UE on EU efficiency and product labelling

su efficienza ed etichettatura dei prodotti ErP e Labelling - guida ai regolamenti UE on EU efficiency and product labelling ErP e Labelling - guida ai regolamenti UE su efficienza ed etichettatura dei prodotti ErP and Labelling - quick guide on EU efficiency and product labelling Settembre 2015 September 2015 2015 ErP/EcoDesign

Dettagli

RAPPORTO DI PROVA: del IDENTIFICAZIONE DELL ARTICOLO (no ) METALLO MINNIE CAMPANELLO METALLO PEPPA PIG CAMP

RAPPORTO DI PROVA: del IDENTIFICAZIONE DELL ARTICOLO (no ) METALLO MINNIE CAMPANELLO METALLO PEPPA PIG CAMP *15.37275* 15.37275 RAPPORTO DI PROVA: 15.37275 Questo rapporto è costituito da 27 pagine, di cui: 3 pagine per il Sommario 3 pagine per il Rapporto di Prova 15.37275a 17 pagine per il Rapporto di Prova

Dettagli

Abstract Women Collection

Abstract Women Collection Abstract collection Head: J 271 Mod.: 3919 Body Col.: 287 Glossy White 2 Head: J 269 Body Col.: Glossy Black Mod.: 3965 3 Head: J 250 Mod.: 3966 Body Col.: 287 Glossy White 4 Head: J 248 Body Col.: 287

Dettagli

.it. .it 7. A1 Posteriore / Rear 200 Lati / Sides 400. Sistemi 3-4 Systems

.it. .it 7. A1 Posteriore / Rear 200 Lati / Sides 400. Sistemi 3-4 Systems Dichiarazione di prestazione in accordo con il Regolamento EU 305/2011 Declaration of performance according to Regulation EU 305/2011 n. codice doc 00335093_1 1. Codice di identificazione unico del prodotto-tipo

Dettagli

Hyppo Swing gate opener

Hyppo Swing gate opener Hyppo Swing gate opener - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l installazione e l uso - Instructions et avertissements pour l installation et l utilisation

Dettagli

Mod. 1067 INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

Mod. 1067 INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003 Mod. 1067 DS1067-019 LBT8388 INTERFACCIA USB/KEY USB/KEY INTERFACE Sch./Ref.1067/003 ITALIANO DESCRIZIONE GENERALE L interfaccia 1067/003 consente di collegare alla Centrale 1067/032 o 1067/042 (ver. 2.00

Dettagli

SPA SOCIETÀ ITALIANA TRASMISSIONI INDUSTRIALI CATALOGO TECNICO - COMMERCIALE TECHNICAL & COMMERCIAL CATALOGUE 03.2004

SPA SOCIETÀ ITALIANA TRASMISSIONI INDUSTRIALI CATALOGO TECNICO - COMMERCIALE TECHNICAL & COMMERCIAL CATALOGUE 03.2004 SPA SOCIETÀ ITALIANA TRASMISSIONI INDUSTRIALI RP CATALOGO TECNICO - COMMERCIALE TECHNICAL & COMMERCIAL CATALOGUE 03.2004 SITI S.p.A. La ringrazia per la fiducia accordata e Le ricorda che il Suo riduttore

Dettagli

INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI

INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI Ai sensi dell art. 13 del Decreto Legislativo 25 luglio 2005, n. 151 "Attuazione delle Direttive 2002/95/CE, 2002/96/CE e 2003/108/CE,

Dettagli

l ascensore su misura

l ascensore su misura insider l ascensore su misura 2 Insider Millepiani è studiato per edifici esistenti la cui natura tecnica, ambientale o amministrativa non consenta la realizzazione di una fossa o di una testata regolamentari

Dettagli

REGISTRATION GUIDE TO RESHELL SOFTWARE

REGISTRATION GUIDE TO RESHELL SOFTWARE REGISTRATION GUIDE TO RESHELL SOFTWARE INDEX: 1. GENERAL INFORMATION 2. REGISTRATION GUIDE 1. GENERAL INFORMATION This guide contains the correct procedure for entering the software page http://software.roenest.com/

Dettagli

ATTESTATO DELL ATTIVITÀ DI VOLONTARIATO CERTIFICATE OF VOLUNTARY ACTIVITIES

ATTESTATO DELL ATTIVITÀ DI VOLONTARIATO CERTIFICATE OF VOLUNTARY ACTIVITIES ASSOCIAZIONE CONSORTI DIPENDENTI MINISTERO AFFARI ESTERI ATTESTATO DELL ATTIVITÀ DI VOLONTARIATO CERTIFICATE OF VOLUNTARY ACTIVITIES ASSOCIAZIONE CONSORT I DIPENDENTI MINISTE RO AFFARI ESTER I ATTESTATO

Dettagli

DICHIARAZIONE DI INCORPORAZIONE DI QUASI MACCHINE

DICHIARAZIONE DI INCORPORAZIONE DI QUASI MACCHINE DA SEMPRE LABEL... Certificazioni 2013 LABEL R&D CERTIFICATO DI CONFORMITà In Label la qualità è parte del core business e della nostra mission. Tutte le innovazioni di prodotto sono sottoposte a rigidi

Dettagli

DICHIARAZIONE DI CONFORMITA' / Declaration of Conformity

DICHIARAZIONE DI CONFORMITA' / Declaration of Conformity Software: SmartLink Versione/Version : 2.1 Edizioni/Editions: SE (Standard Edition) e/and EL (Entry Level) Descrizione del prodotto: SmartLink 2.1 è l interfaccia web remota sviluppata da Software Team

Dettagli

SISTEMI DI SERRAGGIO SH-11 SU-08 SH-13 SU-10 SH-9T SH-12 SU-11 SU-12 SH-08 SH-14 SU-13 SU-14. TEAM WORK SRL www.teamworksrl.net

SISTEMI DI SERRAGGIO SH-11 SU-08 SH-13 SU-10 SH-9T SH-12 SU-11 SU-12 SH-08 SH-14 SU-13 SU-14. TEAM WORK SRL www.teamworksrl.net SU-14 TEAM WORK SRL www.teamworksrl.net SH-14 SU-13 SH-08 SH-12 SU-11 SU-12 SH-9T SH-13 SU-10 SU-08 SH-11 2015 SISTEMI DI SERRAGGIO Bloccaggi Rapidi La soluzione più rapida per il bloccaggio meccanico

Dettagli

AUTORIZZAZIONE ALLA MARCATURA CE MODULO A1 AUTORIZZA AUTHORIZES

AUTORIZZAZIONE ALLA MARCATURA CE MODULO A1 AUTORIZZA AUTHORIZES , quale Organismo Notificato n. 0474, RINA services S.p.A., acting as Notified Body nr. 0474, AUTORIZZA AUTHORIZES il sottoindicato fabbricante: the here below specified manufacturer: Fabbricante Manufacturer

Dettagli

Armadi per Automazione e Distribuzione - Cabinets for automation and distribution. Struttura Base Base Structure. KIT Sismico Bellcore 4

Armadi per Automazione e Distribuzione - Cabinets for automation and distribution. Struttura Base Base Structure. KIT Sismico Bellcore 4 Armadi per Automazione e Distribuzione - Cabinets for automation and distribution Serie BTDA - BTDA series KIT Sismico bellcore 4 Seismic KIT Bellcore 4 Descrizione / Description HSS KSB-bellcore4 API-bellcore4

Dettagli

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS I sistemi mod. i-léd SOLAR permettono di alimentare un carico sia in bassa tensione 12-24V DC, sia a 230v AC, tramite alimentazione

Dettagli

Si comunica che le serrande tagliafuoco modello WK25 We advise that fire dampers model WK25

Si comunica che le serrande tagliafuoco modello WK25 We advise that fire dampers model WK25 Società del gruppo / Belongs to the holding Stålhögavägen 115 26982 Båstad Sweden Si comunica che le serrande tagliafuoco modello WK25 We advise that fire dampers model WK25 Numeri di matricola / Serial

Dettagli

N./No. 0474-CPR-0199. Miscele bituminose - Conglomerato bituminoso prodotto a caldo / Bituminous mixtures - Asphalt Concrete

N./No. 0474-CPR-0199. Miscele bituminose - Conglomerato bituminoso prodotto a caldo / Bituminous mixtures - Asphalt Concrete CERTIFICATO DI CONFORMITÀ DEL CONTROLLO DELLA PRODUZIONE IN FABBRICA / CERTIFICATE OF CONFORMITY OF THE FACTORY PRODUCTION CONTROL N./No. 0474-CPR-0199 In conformità al Regolamento N. 305/2011/EU del Parlamento

Dettagli

C.B.Ferrari Via Stazione, 116-21020 Mornago (VA) Tel. 0331 903524 Fax. 0331 903642 e-mail cbferrari@cbferrari.com 1. Cause di squilibrio a) Asimmetrie di carattere geometrico per necessità di progetto

Dettagli

Consolato d Italia NEWARK RIACQUISTO DELLA CITTADINANZA ITALIANA

Consolato d Italia NEWARK RIACQUISTO DELLA CITTADINANZA ITALIANA Consolato d Italia NEWARK RIACQUISTO DELLA CITTADINANZA ITALIANA Coloro che hanno perso la cittadinanza italiana a seguito di naturalizzazione statunitense avvenuta prima del 16 agosto 1992, possono riacquistarla

Dettagli

LABORATORIO CHIMICO CAMERA DI COMMERCIO TORINO

LABORATORIO CHIMICO CAMERA DI COMMERCIO TORINO LABORATORIO CHIMICO CAMERA DI COMMERCIO TORINO Azienda Speciale della Camera di commercio di Torino clelia.lombardi@lab-to.camcom.it Criteri microbiologici nei processi produttivi della ristorazione: verifica

Dettagli

Rilascio dei Permessi Volo

Rilascio dei Permessi Volo R E P U B L I C O F S A N M A R I N O C I V I L A V I A T I O N A U T H O R I T Y SAN MARINO CIVIL AVIATION REGULATION Rilascio dei Permessi Volo SM-CAR PART 5 Approvazione: Ing. Marco Conti official of

Dettagli

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 SERMONDI SOCIETA' AGRICOLA SEMPLICE

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 SERMONDI SOCIETA' AGRICOLA SEMPLICE Partita IVA 03084760242 Numero identificativo documento giustificativo N reference of Documentary evidence 2013/00555 Numero identificativo N Reference 00471 del 04/12/2014 E' CONFORME AI REQUISITI DEL

Dettagli

n 50 = 2,1 (h -1 ) +/- 6%

n 50 = 2,1 (h -1 ) +/- 6% Studio Tecnico C o n s u l e n z a e n e r g e t i c a E d i l i z i a a b a s s o c o n s u m o I m p i a n t i T e r m i c i R i s p a r m i o E n e r g e t i c o Via S.Rocco 17/a - 12010 Cervasca (CN)

Dettagli

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5 RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5 Rapporto di classificazione di reazione al fuoco del prodotto : Reaction to fire classification report of product BETON COLOR Descrizione

Dettagli

M1.10.RFIS.0351/41478

M1.10.RFIS.0351/41478 10156 TORINO (ITALY) 21, Via Cuorgnè Telefono +39.011.22.22.225 Fax +39.011.22.22.226 e-mail: info@modulouno.it sito: www.modulouno.it RAPPORTO DI PROVA N M1.10.RFIS.0351/41478 Pag. 1 di 9 Cliente / Richiedente

Dettagli

20x SSC Solution. For use in in situ hybridization procedures. For Research Use Only. Not for use in diagnostic procedures.

20x SSC Solution. For use in in situ hybridization procedures. For Research Use Only. Not for use in diagnostic procedures. 20x SSC Solution WB-0003-50 14 (50 ml) For use in in situ hybridization procedures For Research Use Only. Not for use in diagnostic procedures. 1. Scope of Application This product is designed for research

Dettagli

M1.10.RFIS.0355/41478

M1.10.RFIS.0355/41478 10156 TORINO (ITALY) 21, Via Cuorgnè Telefono +39.011.22.22.225 Fax +39.011.22.22.226 e-mail: info@modulouno.it sito: www.modulouno.it RAPPORTO DI PROVA N Pag. 1 di 17 Cliente / Richiedente Customer Costruttore

Dettagli

La saldatura delle strutture metalliche nel quadro della EN 1090

La saldatura delle strutture metalliche nel quadro della EN 1090 Regolamento (UE) n.305/11 e norme del gruppo EN1090 La Marcatura CE delle strutture metalliche alla luce delle Norme tecniche per le Costruzioni Firenze, 30/10/2014 La saldatura delle strutture metalliche

Dettagli

ALLUMINIO e ORO per ESTERNO MRK

ALLUMINIO e ORO per ESTERNO MRK MRK-010-0563 ALLUMINIO e ORO per ESTERNO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco

Dettagli

DOMANDA PER IL RICONOSCIMENTO DEL LABORATORIO DI PROVA APPLICATION FOR ASSESSMENT OF TESTING LABORATORY

DOMANDA PER IL RICONOSCIMENTO DEL LABORATORIO DI PROVA APPLICATION FOR ASSESSMENT OF TESTING LABORATORY ALLEGATO A FACSIMILE DI DOMANDA PER IL RICONOSCIMENTO DEL LABORATORIO DI PROVA DOMANDA PER IL RICONOSCIMENTO DEL LABORATORIO DI PROVA APPLICATION FOR ASSESSMENT OF TESTING LABORATORY Ragione Sociale Name

Dettagli

CERTIFICATO CE. Dichiarazione di approvazione del sistema qualità (Garanzia di qualità della produzione) Certificato n. 1670/MDD MACOSTA MEDITEA SRL

CERTIFICATO CE. Dichiarazione di approvazione del sistema qualità (Garanzia di qualità della produzione) Certificato n. 1670/MDD MACOSTA MEDITEA SRL CERTIFICATO CE Certificato n. 1670/MDD Dichiarazione di approvazione del sistema qualità (Garanzia di qualità della produzione) Visto l'esito delle verifiche condotte in conformità all'allegato V della

Dettagli

Il processo di fabbricazione mediante saldatura di strutture metalliche ed il suo controllo alla luce della EN 1090

Il processo di fabbricazione mediante saldatura di strutture metalliche ed il suo controllo alla luce della EN 1090 Seminario Gestione del livello di qualità nella fabbricazione di strutture e componenti saldati Roma 16 Ottobre 2009 Il processo di fabbricazione mediante saldatura di strutture metalliche ed il suo controllo

Dettagli