1 Datalogger web pulses counter Code: GW-IMP-WEB-1 Version 6 inputs with Ethernet Datalogger web pulses counter The web datalogger pulses counter is able to count the pulses on digital inputs (2 by default expandable). Through the web interface it is possible to display count values, change the weight of the pulse and enter an offset in the event of misalignment or assembly after the installation of the counter. All data can be viewed via web interface or reachable via MODBUS TCP connection (on request also via MODBUS RTU). The datalogger as optional feature can be ordered with time triggered recording of the counters on csv files in the internal memory or in a SD card. Files can be downloaded via ftp Server functionality. 1-EN
2 Features Connections 1 x Serial Port RS232 for reading data from a master Modbus RTU 1 x Ethernet port for reading data from a master Modbus TCP 1 screw connector for power supply VDC (min. 2 W) Signaling LED on the front for communication diagnostic 6 x Digital Input 4 x Digital Output 2 x Analog Input Analog Input Connections Serial Ports Connections 2-EN
3 Web visualization To view the web pages containing the data it is necessary to connect the data logger to the Ethernet network through the RJ45 port. On a web browser just enter the default address: ; If you do not connect, check that you have an address on the network card of the computer on the X subnet. This way you get to the main screen of the data logger with the values of the counters. From this page, through the links at the top of the page, you can access the following pages: - Setting datalogger: Page to set the pulse counter parameters, such as pulse weight and count offset. - Hardware setup: Page to modify the hardware parameters of the pulsecounter as IP address and modbus communication parameters. - Time setup: Page to change the time or activate the NTP protocol. - System: Page to log in to enable changes and to reboot the system. 3-EN
4 Datalogger Settings In the datalogger setting page you can reset the values of the counters, change the weight of the pulses and the offsets. 4-EN
5 Hardware setup After modifying and saving the parameters, the device must be restarted. This can also be done from the System page. System In this page you can login (Username = Admin, Password = Admin), necessary to change the 5-EN
6 parameters, and force the device to restart. Mapping of Modbus memory areas The data read by the PLC are placed in the memory area Holding Register, they occupy 2 WORD, that is 4 BYTE. Nome variabile Tipo Indirizzo MODBUS Note RESET UINT 4x40000 Reset dei contatori INPUT 1 UINT 4x ingresso digitale INPUT 2 UINT 4x ingresso digitale INPUT 3 UINT 4x ingresso digitale INPUT 4 UINT 4x ingresso digitale INPUT 5 UINT 4x ingresso digitale INPUT 6 UINT 4x ingresso digitale CONTATORE 1 REAL 4x contatore: riferito all ingresso 0 CONTATORE 2 REAL 4x contatore: riferito all ingresso 1 CONTATORE 3 REAL 4x contatore: riferito all ingresso 2 CONTATORE 4 REAL 4x contatore: riferito all ingresso 3 CONTATORE 5 REAL 4x contatore: riferito all ingresso 4 CONTATORE 6 REAL 4x contatore: riferito all ingresso 5 PESO_IMP_1 REAL 4x41074 Peso assegnato per gli impulsi sul contatore 1 PESO_IMP_2 REAL 4x41076 Peso assegnato per gli impulsi sul contatore 2 PESO_IMP_3 REAL 4x41078 Peso assegnato per gli impulsi sul contatore 3 PESO_IMP_4 REAL 4x41080 Peso assegnato per gli impulsi sul contatore 4 PESO_IMP_5 REAL 4x41082 Peso assegnato per gli impulsi sul contatore 5 PESO_IMP_6 REAL 4x41084 Peso assegnato per gli impulsi sul contatore 6 OFFSET_1 REAL 4x41124 Offset del contatore 1 OFFSET_2 REAL 4x41126 Offset del contatore 2 OFFSET_3 REAL 4x41128 Offset del contatore 3 OFFSET_4 REAL 4x41130 Offset del contatore 4 OFFSET_5 REAL 4x41132 Offset del contatore 5 OFFSET_6 REAL 4x41134 Offset del contatore 6 6-EN
7 Gateway Size The dimensions of the gateway are as follows: 7-EN
Datalogger web contaimpulsi
Datalogger web contaimpulsi Versione 6 ingressi con Ethernet (GW-IMP-WEB-1) 1 Datalogger web conta impulsi Il datalogger web conta impulsi è in grado di conteggiare gli impulsi sugli ingressi digitali
Guida rapida di installazione
Configurazione 1) Collegare il Router Hamlet HRDSL108 Wireless ADSL2+ come mostrato in figura:. Router ADSL2+ Wireless Super G 108 Mbit Guida rapida di installazione Informiamo che il prodotto è stato
CONFIGURATION MANUAL
RELAY PROTOCOL CONFIGURATION TYPE CONFIGURATION MANUAL Copyright 2010 Data 18.06.2013 Rev. 1 Pag. 1 of 15 1. ENG General connection information for the IEC 61850 board 3 2. ENG Steps to retrieve and connect
User Guide Guglielmo SmartClient
User Guide Guglielmo SmartClient User Guide - Guglielmo SmartClient Version: 1.0 Guglielmo All rights reserved. All trademarks and logos referenced herein belong to their respective companies. -2- 1. Introduction
Guida alla configurazione Configuration Guide
Guida alla configurazione Configuration Guide Configurazione telecamere IP con DVR analogici, compatibili IP IP cameras configuration with analog DVR, IP compatible Menu principale: Fare clic con il pulsante
CCTV DIVISION GUIDA RAPIDA PER LA CONFIGURAZIONE DELL IP STATICO SU SISTEMI TVCC QUICK GUIDE FOR STATIC IP CONFIGURATION ABOUT CCTV SYSTEM
CCTV DIVISION GUIDA RAPIDA PER LA CONFIGURAZIONE DELL IP STATICO SU SISTEMI TVCC QUICK GUIDE FOR STATIC IP CONFIGURATION ABOUT CCTV SYSTEM ITALIANO Principali Step per la configurazione I dispositivi di
Gateway RS485 DLMS-MODBUS. Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP
Gateway RS485 DLMS-MODBUS Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP Gateway RS485 DLMS-MODBUS Il Protocollo DLSM (Device Language Message Specification) viene utilizzato nell'ambito
IF2E001 Interfaccia Ethernet-RS485
IF2E001 Interfaccia Ethernet-RS485 Manuale utente File : Ethernet interfaccia-manuale utente.doc 1/4 Interfaccia Ethernet manuale utente Versione 1.1 1 DESCRIZIONE GENERALE Questo dispositivo consente
EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP.
MANUALE ISTRUZIONI IM471-I v0.2 EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP. Transmission Control
I-Fly Wireless Broadband Router
with 4 Fast Ethernet ports + 1 Wan port Guida Rapida A02-WR-54G/G1 (Novembre 2003)V1.00 Questo manuale è inteso come una guida rapida, pertanto per ulteriori dettagli sulla configurazione fare riferimento
Supporta tutti Marca Modbus Inverter FV e sensore
www.geoprotek.com SUPPORTED INVERTERS: ABB AEG AEI AROS CARLO DANFOSS DELTA EATON ELTEK FRONIUS GREEN POWER MASTERVOLT MITSUBISHI. Supporta tutti Marca Modbus Inverter FV e sensore Come system integrator
Copyright 2012 Binary System srl 29122 Piacenza ITALIA Via Coppalati, 6 P.IVA 01614510335 - info@binarysystem.eu http://www.binarysystem.
CRWM CRWM (Web Content Relationship Management) has the main features for managing customer relationships from the first contact to after sales. The main functions of the application include: managing
IMPORTANTE : La XM200LAN non può essere utilizzata contemporaneamente da più computer. Tasto RESET
XM200LN Made in Italy EMC/2006/95/CE zienda con Sistema di gestione per la Qualità UNI EN ISO 9001:2000 Lead free Pb RoHS compliant REE Modulo connessione LN per centrali Serie XM Tensione nominale di
Guida utente User Manual made in Italy Rev0
Guida utente User Manual Rev0 made in Italy Indice/Index Informazioni generali General Info... 3 Guida Rapida per messa in funzione Start Up procedure... 3 Login Login... 3 Significato dei tasti Botton
ATA-172 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP
ATA-172 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-172 Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 SCHEMA DI COLLEGAMENTO...3 ACCESSO ALL APPARATO...4 CONFIGURAZIONE EUTELIAVOIP...7
STATO IMPLEMENTAZIONE ONVIF SU TELECAMERE MUNDUS SECURUS
IMPLEMENTAZIONE ONVIF SU TELECAMERE MUNDUS SECURUS 1. Ambiente di sviluppo Sono stati analizzati diversi linguaggi e framework differenti utilizzabili per implementare i WebServices ONVIF. Il risultato
Wireless ADSL VPN Firewall Router
Wireless ADSL VPN Firewall Router GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:
Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software
Windows 7 Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software Contenuto del kit cod. 20046946: - Interfaccia PC-scheda (comprensiva
I-STORM LAN ROUTER ADSL
I-STORM LAN ROUTER ADSL with 4 Fast Ethernet ports + 1 USB port Guida rapida all installazione A02-RA2+/G1 (Gennaio 2004)V1.10 Questo manuale è inteso come una guida rapida, pertanto per ulteriori dettagli
Laboratorio di Amministrazione di Sistema (CT0157) parte A : domande a risposta multipla
Laboratorio di Amministrazione di Sistema (CT0157) parte A : domande a risposta multipla 1. Which are three reasons a company may choose Linux over Windows as an operating system? (Choose three.)? a) It
PIRELLI Discus NetGate VoIP v2 VOIP ADSL ROUTER GUIDA ALL INSTALLAZIONE
VoIP ADSL Router Discus NetGate VoIP v2 Pirelli (0.56S) Manuale operativo Pag. 1 PIRELLI Discus NetGate VoIP v2 VOIP ADSL ROUTER GUIDA ALL INSTALLAZIONE Release 0.56S VoIP ADSL Router Discus NetGate VoIP
Posta elettronica per gli studenti Email for the students
http://www.uninettunouniverstiy.net Posta elettronica per gli studenti Email for the students Ver. 1.0 Ultimo aggiornamento (last update): 10/09/2008 13.47 Informazioni sul Documento / Information on the
Manuale utente. Quinx Box serie 200/300/400. Ethernet RS232 - TCP/IP converter
Manuale utente Quinx Box serie 200/300/400 Ethernet RS232 - TCP/IP converter A cura di: ICG Holding srl Div. Time & Access Via Leonardo da Vinci 45/47 20020 Lainate (MI) Nr. rif. Q 200 001 Versione 1.10.97
ATA-G81022MS GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP
ATA-G81022MS GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-G81022MS Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 SCHEMA DI COLLEGAMENTO...3 ACCESSO ALL APPARATO...4 CONFIGURAZIONE EUTELIAVOIP...7
CloudEvolution is a plant monitoring and supervision system (via Web).
CloudEvolution Plant monitoring and supervision system (via Web) Sistema di monitoraggio e di supervisione di impianti (via Web) CloudEvolution is a plant monitoring and supervision system (via Web). With
WEB SERVER. per modulo MCIMIDETH. for MCIMIDETH module. Manuale d uso. User manual
WEB SERVER for MCIMIDETH module per modulo MCIMIDETH User manual Manuale d uso Ipm0205.0 - Edizione / Edition 11.14 FRER SRL Viale Europa, 12 20093 Cologno Monzese (MI) ITALY Tel. : +39 02 27302828 Fax
Mod. 1067 VIDEO GATEWAY A 4 CANALI 4 CHANNELS VIDEO GATEWAY. Sch./Ref.1067/450
Mod. 1067 DS1067-017 LBT8386 VIDEO GATEWAY A 4 CANALI 4 CHANNELS VIDEO GATEWAY Sch./Ref.1067/450 Fig. 1 Fig. 2 Fig. 3 Fig. 4 A B A B C D E 2 DS1067-017 ITALIANO DESCRIZIONE GENERALE Modulo video con 4
MC-link Spa. Pannello frontale del Vigor2700e. Installazione hardware del Vigor2700e
MC-link Spa Pannello frontale del Vigor2700e Installazione hardware del Vigor2700e Questa sezione illustrerà come installare il router attraverso i vari collegamenti hardware e come configurarlo attraverso
PG5 Starter Training Applicazione File System Daniel Ernst EN02 2012-02-26 Stefano Peracchi IT01 2013-05-20
PG5 Starter Training Applicazione File System Daniel Ernst EN02 2012-02-26 Stefano Peracchi IT01 2013-05-20 Introduzione Materiale richiesto Notebook o computer Controllore PCD1 E Cavo USB Scheda «Training»
MODBUS MASTER. per modulo MCIMIDMDB. for MCIMIDMDB module. Manuale d uso. User manual
MODBUS MASTER for MCIMIDMDB module per modulo MCIMIDMDB User manual Manuale d uso Ipm0203.0 - Edizione / Edition 04.14 FRER SRL Viale Europa, 12 20093 Cologno Monzese (MI) ITALY Tel. : +39 02 27302828
MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS
MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS COMPATIBILE CON - COMPATIBLE WITH LP14/20/30 SCHEDA - MOTHERBOARD 512 E SW V5 2 IT COLLEGAMENTO A MURO DELLA CONSOLE LCD - CALDAIA Collegamento
ITALIANO. Porta seriale DB25 RS-232/RS-422/RS485 femmina con configurazione DCE Da 300 baud a 115 Kbaud. Hardware CTS/RTS
ITALIANO 1. Generalità Il convertitore INTHETERNET permette di collegare ad una rete ETHERNET le centrali M5000 e M3000 e di gestirle con il pacchetto SW5000 o AMIGO. Il dispositivo permette di assegnare
Contatori CEWEPrometer R/W Convertitore di protocollo IEC 62056-21 (IEC1107) / Modbus RTU CEWEMod MANUALE DI CONFIGURAZIONE
Tecniche di misura e Automazione Staer S.r.l. Uffici Via Sibilla Aleramo,4 20090 Segrate (MI) Tel. 02/26952067 Fax. 02/26922849 info@staermisure.it www.staermisure.it Sede legale Via Buonarroti, 3 20050
Guida all utilizzo del modulo MPI BrainChild
Document version: 1.0 easitec S.r.l. Viale Martiri della Benedicta, 102 15069 Serravalle Scrivia (AL) - Italy Phone +39.0143.686023 - Fax +39.0143.634777 info@easitec.it - www.easitec.it Revision History
Router Firewall 802.11g ADSL VPN
Router Firewall 802.11g ADSL VPN GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com 1 NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:
Software. IF96015 Manuale d uso User s guide. Ethernet. WebServer 10782690W
IF96015 Manuale d uso User s guide IF Software Ethernet WebServer I ISTRUMENTI MISURE ELETTRICHE SpA 10782690W Via Travaglia 7 20094 CORSICO (MI) ITALIA Tel. +39 02 44 878.1 www.imeitaly.com info@imeitaly.com
PIRELLI DISCUS NETGATE VoIP v2 GUIDA ALL INSTALLAZIONE. Pirelli Discus Netgate Guida all installazione EUTELIAVOIP Rev1-0
PIRELLI DISCUS NETGATE VoIP v2 GUIDA ALL INSTALLAZIONE Pirelli Discus Netgate Guida all installazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA...3 COLLEGAMENTO
ROUTER ADSL2 FIREWALL WIRELESS
ROUTER ADSL2 FIREWALL WIRELESS GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com 1 NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:
Contatori di Energia MID
Mettersi insieme è un inizio, stare insieme è un progresso, lavorare insieme è un successo. Henry Ford Novità serie UEM: Contatori di energia con comunicazione integrata UEM1P5 Contatore trifase per TA
Mistral Lan Router ISDN
Mistral Lan Router ISDN with 4 Fast Ethernet ports + BroadBand Interface Guida Rapida V1.0 A02-RI/G1 (Settembre 2003) Questo manuale è inteso come una guida rapida, pertanto per ulteriori dettagli sulla
REGISTRATION GUIDE TO RESHELL SOFTWARE
REGISTRATION GUIDE TO RESHELL SOFTWARE INDEX: 1. GENERAL INFORMATION 2. REGISTRATION GUIDE 1. GENERAL INFORMATION This guide contains the correct procedure for entering the software page http://software.roenest.com/
Guida all installazione rapida
Italian 1. Guida all installazione rapida Requisiti del sistema Il PC deve essere attrezzato con quanto segue per configurare Thecus YES Box N2100: Unità CD-ROM o DVD-ROM Porta Ethernet collegata ad un
Doc. I357 IGB 1013.docx 24/10/2013 P. 1 / 5
SERIE DMG-DME-RGK DMG-DME-RGK SERIES I357 I GB 1013 FUNZIONE WEB SERVER WEB SERVER FUNCTION Doc. I357 IGB 1013.docx 24/10/2013 P. 1 / 5 INTRODUZIONE La funzione web server rende visualizzabili via web
Mod. 1067 INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003
Mod. 1067 DS1067-019 LBT8388 INTERFACCIA USB/KEY USB/KEY INTERFACE Sch./Ref.1067/003 ITALIANO DESCRIZIONE GENERALE L interfaccia 1067/003 consente di collegare alla Centrale 1067/032 o 1067/042 (ver. 2.00
IP 500 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP
IP 500 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP Phone - Perfectone IP 500 - Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP500...3
Blocchi funzione: FbModbusAsciiMs
Pagina 1 di 6 ELSIST Srl, www.elsist.it Blocchi funzione MNL041Q000 FbModbusAsciiMs Questo blocco funzione permette lo scambio di dati tra due sistemi, uno master ed uno slave, utilizzando una connessione
Plugin Single Sign-On
NEXT-GEN USG Plugin Single Sign-On Configurazione Agent SSO su AD Verificare di avere l ultima release del client SSO installato su Windows Server. AL momento di redigere la guida la più recente è la 1.0.3
STE04WS MANUALE UTENTE V. 1.0
STE04WS MANUALE UTENTE V. 1.0 INDICE 1 DICHIARAZIONE DI CONFORMITÀ 3 2 INTRODUZIONE 3 3 CARATTERISTICHE TECNICHE 3 3.1 PROTOCOLLI SUPPORTATI 3 3.2 CONNESSIONE ALLA RETE ETHERNET 3 3.3 PORTA SERIALE 3 3.4
VTE01 MANUALE UTENTE V. 1.0
VTE01 MANUALE UTENTE V. 1.0 INDICE 1 CONNESSIONI E LED 3 1.1 LED PWR 3 1.2 LED RUN 3 2 INTERFACCIA DI CONFIGURAZIONE 4 2.1 INTRODUZIONE 4 2.2 PASSWORD CHECK 4 2.3 CHANGE PASSWORD 5 2.4 CAMERA SETTINGS
DICHIARAZIONE DI RESPONSABILITÀ
- 0MNSWK0082LUA - - ITALIANO - DICHIARAZIONE DI RESPONSABILITÀ Il produttore non accetta responsabilità per la perdita di dati, produttività, dispositivi o qualunque altro danno o costo associato (diretto
Sistema modulare per visualizzazione prezzi carburanti.
Sistema modulare per visualizzazione prezzi carburanti. La gamma NAUTILUS, nata dall esperienza maturata dalla nostra azienda in oltre 36 anni di attività nella progettazione e produzione di sistemi di
LINKSYS SPA922 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP
LINKSYS SPA922 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Linksys SPA922 - Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 COLLEGAMENTO FISICO APPARATO...3 ACCESSO ALL ADMINISTRATOR WEB
CONFIGURAZIONE VIA WEB BROWSER
CONFIGURAZIONE VIA WEB BROWSER Prima di procedere con la configurazione del vostro Pirelli NetGate VoIP via WEB Browser è importante che vi assicuriate di avere a disposizione i dati della connessione
WELCOME. Go to the link of the official University of Palermo web site www.unipa.it; Click on the box on the right side Login unico
WELCOME This is a Step by Step Guide that will help you to register as an Exchange for study student to the University of Palermo. Please, read carefully this guide and prepare all required data and documents.
Comunicatore Bluetooth DEA300 Manuale d uso
1. Introduzione Comunicatore Bluetooth DEA300 Manuale d uso Il presente manuale è una guida per la configurazione e l installazione del comunicatore Bluetooth DEA300 ai datalogger LSI LASTEM. 2. Configurazione
Guida di avvio rapido Quick Start Guide
Guida di avvio rapido Quick Start Guide 46840.W04, 46840.W08, 46840.W16 DVR con tecnologia full WD1 a 4-8-16 canali in tempo reale e HDD 1TB DVR full WD1 realtime 4-8-16 canali HDD 1TB 1. Note Leggere
Global network of innovation Simatic S7-200 comunicazioni
Global network of innovation Simatic S7-200 comunicazioni SIMATIC S7-200 5 cpu Max 24 kb prog 248 I/O 6 HSC Text Display programmabili con Microwin Wizard (programmazione semplificata) 8 PID Moduli di
4-441-095-52 (1) Network Camera
4-441-095-52 (1) Network Camera Guida SNC easy IP setup Versione software 1.0 Prima di utilizzare l apparecchio, leggere attentamente le istruzioni e conservarle come riferimento futuro. 2012 Sony Corporation
Manuale di installazione SunGuard V. 7.0 Italiano. www.sunguard.it
Manuale di installazione SunGuard V. 7.0 Italiano www.sunguard.it 1 INTRODUZIONE Grazie per aver scelto il sistema di monitoraggio SunGuard. Questo manuale contiene istruzioni dettagliate riguardanti l
group STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER CAN J1939 ISOBUS - ISO11783 VT3 SOFTWARE DEVELOPMENT TOOLS IEC 61131
group STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER IEC 61131 VT3 SOFTWARE DEVELOPMENT TOOLS CAN J1939 ISOBUS - ISO11783 1 STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER 2 SPECIFICHE TECNICHE
Router ISDN + Switch 4 porte
Router ISDN + Switch 4 porte GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com LED PANNELLO ANTERIORE LED Significato 1 PWR Quando lampeggia, indica che l impianto è pronto. 2 3 LAN 1-4 / ACT/COL WAN / ACT/COL
WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]
WIN / PROFIBUS Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. -] Load cells digital amplifier with PROFIBUS DP-V1 interface... ENGLISH [Pag. 4-5] Display di
Interfaccia Ethernet RS485 TCP/ModBus
IF2E011 - IF2E111 Manuale istruzioni d uso interfaccia Interface user s guide Interfaccia Ethernet RS485 TCP/ModBus I ISTRUMENTI MISURE ELETTRICHE SpA Via Travaglia 7 20094 CORSICO (MI) ITALIA Tel. +39
Unità di telelettura per contatori
Unità di telelettura per contatori Funzionalità : 5 Ingressi digitali, per segnali GME (ingresso S0) 1 Uscita digitale, per segnalazione di allarme seriale RS232 o RS485, protocolli ModBus o DLMS per comunicazione
RS 485 PER INTERFACCIARE IL PC. DISPLAY, Visualizza, A, V, Hz,P.
STRUMENTO MULTIFUNZIONE MONOFASE Lo strumento in questione occupa 1 DIN (18 mm) e si alloggia facilmente in un normale quadretto, anche di tipo casalingo, che abbia la guida DIN, lo strumento va installato
Z-GPRS2 / Z-GPRS2-SEAL IL PIÙ SEMPLICE SISTEMA DI TELEGESTIONE PER APPLICAZIONI UNIVERSALI
/ -SEAL IL PIÙ SEMPLICE SISTEMA DI TELEGESTIONE PER APPLICAZIONI UNIVERSALI DATALOGGER GSM/GPRS CON I/O INTEGRATO E FUNZIONI DI TELECONTROLLO 100% Made & Designed in Italy EASY Z GPRS2 EASY LOG VIEWER
You can visualize the free space percentage in Compact Flash memory from the MENU/INFO C.F. UTILITY-FREE SPACE page.
This release introduces some new features: -TUNE PITCH -FREE SPACE -TUNER -DRUMKIT EDITOR From the PARAM MIDI page, it is possible to modify the "TUNE PITCH" parameter, which allows you to tune up the
Gateway da PROFIBUS DP, DeviceNet, CANopen, Modbus TCP a Modbus RTU serie deltadue
BT. 02.30 DXDY/I Gateway da PROFIBUS DP, DeviceNet, CANopen, TCP a serie deltadue Integra le linee di strumentazione ASCON nel tuo sistema DX 5000 Convertitore di linea RS232/ Ripetitore / Adattatore di
DSL-G604T Wireless ADSL Router
Il prodotto può essere configurato con un qualunque browser aggiornato come Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-G604T Wireless ADSL Router Prima di cominciare 1. Se si intende utilizzare
PROCEDURA DI CONFIGURAZIONE: Per configurare i parametri di rete dell RCX LAN è necessario installare il software Tibbo DS Manager
Via S. Antonio, 47 35030 Veggiano PD Tel: 04441800191 Fax: 0497960910 www.shitek.it info@shitek.it RCX LAN Wi -Fi RCX LAN Wi-Fi MAN_00023_ita_RCX_LAN Ca PROCEDURA DI CONFIGURAZIONE: 1. PARAMETRI PER LA
Portale Materiali Grafiche Tamburini. Grafiche Tamburini Materials Portal
Portale Materiali Grafiche Tamburini Documentazione utente italiano pag. 2 Grafiche Tamburini Materials Portal English user guide page 6 pag. 1 Introduzione Il Portale Materiali è il Sistema Web di Grafiche
PROTOCOLLO MODBUS RTU
Progettato e prodotto interamente in Italia CONTABILIZZATORE DI IMPULSI MONTAGGIO GUIDA DIN PROTOCOLLO MODBUS RTU Il protocollo di comunicazione è MODBUS, conforme alle specifiche Modbus Application Protocol
Quando mi collego ad alcuni servizi hosting ricevo un messaggio relativo al certificato di protezione del sito SSL, come mai?
IT FAQ-SSL Quando mi collego ad alcuni servizi hosting ricevo un messaggio relativo al certificato di protezione del sito SSL, come mai? Il certificato SSL relativo ai servizi hosting è stato rinnovato
CONNESSIONE WI-FI - GUIDA RAPIDA WI-FI CONNECTION - QUICK START GUIDE SUNWAY M XS
CONNESSIONE WI-FI - GUIDA RAPIDA WI-FI CONNECTION - QUICK START GUIDE SUNWAY M XS CONNETTIVITÀ SEMPLICE ED ESTESA SIMPLE AND FULL CONNECTIVITY CONNESSIONE AD HOC AD HOC CONNECTION CONNESSIONE Router ROUTER
Prima di iniziare la procedura d installazione, verificare che siano disponibili tutte le informazioni e le attrezzature necessarie
Il presente prodotto può essere configurato con un browser web aggiornato come Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-502T ADSL Router Prima di cominciare Prima di iniziare la procedura d
SIP PHONE Perfectone IP301 Manuale Operativo PHONE IP301 GUIDA ALL INSTALLAZIONE
pag.1 PHONE IP301 GUIDA ALL INSTALLAZIONE pag.2 INDICE SERVIZIO VOIP SKYPHO...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP301...3 COLLEGAMENTO FISICO APPARATO...4 ACCESSO ALL APPARATO...8 Accesso all IP
Guida di installazione rete wireless NPD4759-00 IT
Guida di installazione rete wireless NPD4759-00 IT Controllo della rete Verificare le impostazioni di rete del computer, quindi scegliere cosa fare. Seguire le istruzioni per l'ambiente in cui funzionano
CD-ROM (contiene Manual y garantía) Cavo Ethernet (CAT5 UTP/diritto) Cavo Console (RS-232)
Il presente prodotto può essere configurato con un qualunque browser, come Internet Explorer 6 o Netscape Navigator 6 o versioni superiori. DFL-700 NETDEFEND Network Security Firewall Prima di cominciare
Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender N 300Mbps TL-WA850RE
Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender N 300Mbps TL-WA850RE È possibile usare questo metodo solo se il vostro Router o Access Point (AP) supporta WPS. 1. Accensione 3. Riposizionamento
1 Presentazione generale 1.1 Accessori 1.2 Specifiche 1.3 Configurazione di rete predefinita 1.4 Impostazioni PTZ 2 Struttura 2.
IT EN. 1 Presentazine generale 1.1 Accessri 1.2 Specifiche 1.3 Cnfigurazine di rete predefinita 1.4 Impstazini PTZ 2 Struttura 2.1 Dimensini 2.1.1 Supprt di fissaggi a parete (in dtazine) 2.1.2 Supprt
Parallelamente, il REWIND può essere utilizzato per comunicare con il software di supervisione SICES SUPERVISOR
REWIND: Dispositivo elettronico che, sfruttando la tecnologia GSM/GPRS e abbinato ad gruppo elettrogeno, una torre faro, cisterna/serbatoio, ecc..., consente l invio automatico di pacchetti di dati al
DI-604 Express EtherNetwork Broadband Router
Il presente prodotto può essere configurato con un qualunque browser, per esempio, Internet Explorer 5x, Netscape Navigator 4x.` DI-604 Express EtherNetwork Broadband Router Prima di cominciare 1. Se si
ESEMPI INTEGRAZIONE PRODOTTI
System Manual ESEMPI INTEGRAZIONE PRODOTTI Connessione di un Momentum ad un PC attraverso un dispositivo CEV30020 SM_CEVMBSMOM SOMMARIO 1 - OGGETTO 2 - ARCHITETTURA 2.1 - Hardware 2.2 - Software 2.3 -
Z-GPRS2 Z-GPRS2-SEAL
100% Made & Designed in Italy -SEAL DATALOGGER GSM/GPRS CON I/O INTEGRATO E FUNZIONI DI TELECONTROLLO EASY EASY LOG VIEWER ADVANCED LANGUAGE IL PIÙ SEMPLICE SISTEMA DI TELEGESTIONE PER APPLICAZIONI UNIVERSALI
Unità intelligenti serie DAT9000
COMPONENTI PER L ELETTRONICA INDUSTRIALE E IL CONTROLLO DI PROCESSO Unità intelligenti serie DAT9000 NUOVA LINEA 2010 www.datexel.it serie DAT9000 Le principali funzioni da esse supportate, sono le seguenti:
NDCMB NDCMB MOTORIDUTTORI C.C. AD ASSI ORTOGONALI RARE EARTH D.C. BEVEL HELICAL GEARMOTORS
Pag. Page Indice Index Caratteristiche tecniche Technical features D2 Designazione Classification D2 Sensi di rotazione Direction of rotation D2 Simbologia Symbols D2 Lubrificazione Lubrication D3 Carichi
DSL-G604T Wireless ADSL Router
Il presente prodotto può essere configurato con un browser web aggiornato come Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-G604T Wireless ADSL Router Prima di cominciare 1. Se si intende utilizzare
Metodo 1: Quick Setup tramite tasto WPS
Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender RE200 AC750 Si può usare questo metodo solo se il vostro Router o Access Point(AP) supporta WPS. 1. Accensione 2. Premete i 2 pulsanti WPS
Quick start manual Manuale rapido. Version 3.0
Quick start manual Manuale rapido Version 3.0 1 Scope of delivery Contenuto della fornitura CITREX Mini USB cable, power cable Cavo di alimentazione Mini USB Plug-in power supply Alimentatore per rete
Prima di cominciare verificare la disponibilità di tutti i componenti e le informazioni necessarie. Modem ADSL DSL-300T. CD-ROM (contenente manuale )
Il presente prodotto può essere configurato con un qualunque browser web aggiornato, per esempio Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-300T Modem ADSL Prima di cominciare Prima di cominciare
Kit trasmissione. data transmission. Ref. 10085
Kit trasmissione dati WIRELESS Kit for wireles data transmission Ref. 10085 MANUALE UTENTE aspetto componenti A Chiavetta USB per connesione al PC B Strumento rilavazione dati C Adattatore 1 Connettore
How to use the WPA2 encrypted connection
How to use the WPA2 encrypted connection At every Alohawifi hotspot you can use the WPA2 Enterprise encrypted connection (the highest security standard for wireless networks nowadays available) simply
group HIGH CURRENT MULTIPLEX NODE
HIGH CURRENT MULTIPLEX NODE edizione/edition 04-2010 HIGH CURRENT MULTIPLEX NODE DESCRIZIONE GENERALE GENERAL DESCRIPTION L'unità di controllo COBO è una centralina elettronica Multiplex Slave ; la sua
D-LINK DPH-140S SIP PHONE GUIDA ALL INSTALLAZIONE
pag.1 D-LINK DPH-140S SIP PHONE GUIDA ALL INSTALLAZIONE pag.2 INDICE SERVIZIO VOIP SKYPHO...3 COMPONENTI PRESENTI NELLA SCATOLA DEL DPH-140S...3 COLLEGAMENTO FISICO APPARATO...4 ACCESSO ALL'APPARATO...6
MANUALE UTENTE MODULO ESPANSIONE TASTI MANUALE UTENTE MANUALE UTENTE Descrizione Il modulo fornisce al telefono VOIspeed V-605 flessibilità e adattabilità, mediante l aggiunta di trenta tasti memoria facilmente
D-LINK DPH-140S SIP PHONE GUIDA ALL INSTALLAZIONE
D-LINK DPH-140S SIP PHONE GUIDA ALL INSTALLAZIONE SIP PHONE D-LINK DPH-140S Guida all installazione Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DEL DPH-140S...3 COLLEGAMENTO
ECVCON MANUALE DI INSTALLAZIONE INSTALLATION MANUAL
ECVCON MANUALE DI INSTALLAZIONE INSTALLATION MANUAL INDICE ECVCON Introduzione... pag. 3 Caratteristiche... pag. 4 Messa in funzione... pag. 6 Inserimento della SIM... pag. 6 Connessione al PC per la prima
Problemi Una descrizione dei problemi sorti durante le fasi di
Etichetta del test case Composta da: - DUT : Device Under Test; - Numero/i incrementale/i: per identificare la gerarchia di appartenenza; - Tipologia: TP (throughput), LT (latenza), FL (Frame Loss); -
GE Fanuc Automation. Page 1/12
GE FANUC Data Server FTP Server - Configurazione - Page 1/12 Revision History Version Date Author Notes 1.00 05-Jun-2002 M. Bianchi First release Summary 1 Introduzione... 3 1.1 Riferimenti... 3 2 Configurazione
SYSTEM MANUAL SM_0007.1 ESEMPI INTEGRAZIONE PRODOTTI. Teleassistenza Twido-Suite & Twido
SYSTEM MANUAL ESEMPI INTEGRAZIONE PRODOTTI Teleassistenza Twido-Suite & Twido SM_0007.1 Si realizza una connessione remota con l ausilio dell Internet Protocol Suite, di cui in particolare i protocolli