1 USER S MANUAL Gateway DLMS-MODBUS for ISKRA with RS485 P/N: GW-DLMS-485-ISK Edition 2.0 MARCOM SRL Phone info@marcomweb.it Via Mezzacampagna 52 (int. 29)

2 Revision Sheet Revision Sheet Release Date Revision Description No. Rev. 0 10/05/14 User s Manual Template and Checklist Rev. 1 10/06/16 Conversion to new format Rev. 2 30/01/17 New HomeDLMS page Rev. 3 20/05/18 New hardware configuration pages. Rev. 4 08/11/18 MT880 meter User s Manual GW-DLMS-485-ISK Page i

3 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION System Overview ISKRA MT880 compatibility Features Connections Digital Input connection Serial port connections CONFIGURATION AND MODBUS MAP Web Visualization Communication with energy meter Gateway Settings Modbus Mapping Area COMMUNICATION ERRORS Type of error MECHANICAL FEATURES User s Manual GW-DLMS-485-ISK Page ii

4 1.0 GENERAL INFORMATION 1.1 System Overview DLMS (Device Language Message Specification) Protocol is used in meters field and specifically in electric Energy meter to readout consumption and other values. The reference standard is EC This standard defines services which permit to read objects, OBIS defined. Inside these objects are mapped running meter values using standard profiles. By Gateway DLMS-MODBUS is possible to read DLMS energy meter s data using MODBUS RTU or MODBUS TCP protocol. The gateway is completely transparent to DLMS protocol, so user must know only Modbus protocol. This Gateway version reads data from up to three meters through the RS485 port and provides value to two RS232 port MODBUS RTU slave and on an Ethernet port Modbus TCP Server (up to 3 client connections) ISKRA MT880 compatibility The MT880 counter is not compatible with the gateway by default. It is therefore recommended to ask the installer / seller of the counter to change the counter configuration like this: activate the IEC protocol on the serial port to be connected to the gateway reduce to a maximum 2 the number of previous values of the obis in the readout message of the counter User s Manual GW-DLMS-485-ISK Page 3

5 1.2 Features Connections Gateway has following communication ports: 2 x Serial RS232 port to read energy meter s data by master Modbus RTU 1 x Serial RS485 port to connect up to three energy meter 1 x Ethernet port to read Energy meter s data by client Modbus TCP 1 screw connector to supply gateway VDC (min. 2 W) Front Signal LED for communication diagnostic 2 x Digital Input (*) 2 x Digital Output (*) (*) Their status is mapped in Modbus registers Digital Input connection The schema of two digital input/output connection is: User s Manual GW-DLMS-485-ISK Page 4

6 1.2.3 Serial port connections The schema of serial ports RS232 and RS485: User s Manual GW-DLMS-485-ISK Page 5

7 2.0 CONFIGURATION AND MODBUS MAP 2.1 Web Visualization To view the web pages containing the data read from the counter you need to connect to the network using the Ethernet RJ45 port available on the gateway. By a web browser, just type the default address In case of connection failure ensure that you have on your network card address on a subnet X. This brings us to the main screen of the Gateway with the values common to all Meter User s Manual GW-DLMS-485-ISK Page 6

8 From this page, through the links at the top of the page, you can browse web pages that contain the data for the single Meter or go on the configuration pages of the Gateway (Home PLC). 2.2 Communication with energy meter In order to activate communication with energy meter user must insert in proper field Serial coder Meter x the serial numbers of connected meters. It s possible to change baudrate of the port connected to meter from Serial port baudrate selection in case meter works with speed different from 9600 that usually is standard. Time between readouts can be set from 10 to 3600 seconds. String debug is useful to understand the communication with meters. With GATEWAY REBOOT button you can force the gateway to reboot. The confirmation of the changes is recorded using the Submit button. 2.3 Gateway Settings To change the gateway settings, such as IP address, you need access to the configuration pages through the link HomePLC in the header of web pages that contain the data read from the counters. The Home page summarizes the main information concerning the gateway as the serial and with the navigation bar on the left you can move between the pages. Credentials to login and modify parameters are: Username = Admin, Password = Admin. Changes in gateway settings are applied to the gateway after a power reboot. User s Manual GW-DLMS-485-ISK Page 7

9 To change the parameters of the serial connections (baudrate, parity) and ethernet, such as the IP address, just go to the Devices page and, by clicking on the gear icon for the selected port, a popup will open with the settings. The two RS232 ports are COM0 and COM1 while the RS485 port is COM2. Modifications to the COM2 port are not necessary as the parameters are forced by the software. User s Manual GW-DLMS-485-ISK Page 8

10 To change the modbus node of the RTU or TCP server, open the Protocols page and modify the parameters of the desired interface. 2.4 Modbus Mapping Area The data read from the meters are placed in the Holding Register area. A copy of the values is also present in the 4x20000 holding register area. In case of obis not found in the message from meter you will find -1 value. Refresh time of the values is approximately: Time between readouts * N, where N is the number of energy meters connected to gateway and configured with a serial number different from zero in HomeDLMS. Modbus addresses in the table are base 1; depending on used Modbus master, sometimes is required to swap words to read data correctly. OBIS INDEX OBIS CODE METER 1 METER 2 METER 3 DATA TYPE - - 4x40000 UINT DI x40001 UINT DI x40002 UINT DO x40003 UINT DO 01 NOTE - - 4x x x40008 ULONG Energy meter s serial code to start communication - - 4x40012 FLOAT Index reading meter - - 4x40014 FLOAT Error number 0 F.F 4x x x40416 LONG Error Code x x x40418 LONG Time User s Manual GW-DLMS-485-ISK Page 9

11 x x x40420 LONG Date x x x40422 LONG Address x x x40424 FLOAT Billing period counter * 4x x x40426 FLOAT Time stamp of the billing period x x x40428 FLOAT Sum Li Active power+ (QI+QIV) x x x40430 FLOAT Sum Li Active power- (QII+QIII) x x x40432 FLOAT Sum Li Reactive power QI x x x40434 FLOAT Sum Li Reactive power QII x x x40436 FLOAT Sum Li Reactive power QIII x x x40438 FLOAT Sum Li Reactive power QIV x x x40440 FLOAT Max Active Power - Import - Tariff 1 (kw) * 4x x x40442 FLOAT Max Active Power - Import - Tariff 1 (kw) - previous period x x x40444 FLOAT Max Active Power - Import - Tariff 2 (kw) * 4x x x40446 FLOAT Max Active Power - Import - Tariff 2 (kw) - previous period x x x40448 FLOAT Max Active Power - Import - Tariff 3 (kw) * 4x x x40450 FLOAT Max Active Power - Import - Tariff 3 (kw) - previous period x x x40452 FLOAT Max Active Power - Export - Tariff 1 (kw) * 4x x x40454 FLOAT Max Active Power - Export - Tariff 1 (kw) - previous period x x x40456 FLOAT Max Active Power - Export - Tariff 2 (kw) * 4x x x40458 FLOAT Max Active Power - Export - Tariff 2 (kw) - previous period x x x40460 FLOAT Max Active Power - Export - Tariff 3 (kw) * 4x x x40462 FLOAT Max Active Power - Export - Tariff 3 (kw) - previous period x x x40464 FLOAT Active Energy - Import - Total (kwh) * 4x x x40466 FLOAT Active Energy - Import - Total (kwh) - previous period x x x40468 FLOAT Sum Li Active power+ (QI+QIV) - Tariff * 4x x x40470 FLOAT Sum Li Active power+ (QI+QIV) - Tariff 1 - previous period x x x40472 FLOAT Sum Li Active power+ (QI+QIV) - Tariff * 4x x x40474 FLOAT Sum Li Active power+ (QI+QIV) - Tariff 2 - previous period x x x40476 FLOAT Sum Li Active power+ (QI+QIV) - Tariff * 4x x x40478 FLOAT Sum Li Active power+ (QI+QIV) - Tariff 3 - previous period x x x40480 FLOAT Active Energy - Export - Total (kwh) * 4x x x40482 FLOAT Active Energy - Export - Total (kwh) - previous period x x x40484 FLOAT Sum Li Active power- (QII+QIII) - tariff * 4x x x40486 FLOAT Sum Li Active power- (QII+QIII) - tariff 1 - previous period x x x40488 FLOAT Sum Li Active power- (QII+QIII) - tariff * 4x x x40490 FLOAT Sum Li Active power- (QII+QIII) - tariff 2 - previous period x x x40492 FLOAT Sum Li Active power- (QII+QIII) - tariff * 4x x x40494 FLOAT Sum Li Active power- (QII+QIII) - tariff 3 - previous period x x x40496 FLOAT Reactive Energy QI - Total (kvarh) * 4x x x40498 FLOAT Reactive Energy QI - Total (kvarh) - previous period x x x40500 FLOAT Sum Li Reactive power QI - Tariff * 4x x x40502 FLOAT Sum Li Reactive power QI - Tariff 1 - previous period x x x40504 FLOAT Sum Li Reactive power QI - Tariff * 4x x x40506 FLOAT Sum Li Reactive power QI - Tariff 2 - previous period x x x40508 FLOAT Sum Li Reactive power QI - Tariff * 4x x x40510 FLOAT Sum Li Reactive power QI - Tariff 3 - previous period x x x40512 FLOAT Reactive Energy QII - Total (kvarh) * 4x x x40514 FLOAT Reactive Energy QII - Total (kvarh) - previous period User s Manual GW-DLMS-485-ISK Page 10

12 x x x40516 FLOAT Sum Li Reactive power QII - Tariff * 4x x x40518 FLOAT Sum Li Reactive power QII - Tariff 1 - previous period x x x40520 FLOAT Sum Li Reactive power QII - Tariff * 4x x x40522 FLOAT Sum Li Reactive power QII - Tariff 2 - previous period x x x40524 FLOAT Sum Li Reactive power QII - Tariff * 4x x x40526 FLOAT Sum Li Reactive power QII - Tariff 3 - previous period x x x40528 FLOAT Reactive Energy QIII - Total (kvarh) * 4x x x40530 FLOAT Reactive Energy QIII - Total (kvarh) - previous period x x x40532 FLOAT Sum Li Reactive power QIII - Tariff * 4x x x40534 FLOAT Sum Li Reactive power QIII - Tariff 1 - previous period x x x40536 FLOAT Sum Li Reactive power QIII - Tariff * 4x x x40538 FLOAT Sum Li Reactive power QIII - Tariff 2 - previous period x x x40540 FLOAT Sum Li Reactive power QIII - Tariff * 4x x x40542 FLOAT Sum Li Reactive power QIII - Tariff 3 - previous period x x x40544 FLOAT Reactive Energy QIV - Total (kvarh) * 4x x x40546 FLOAT Reactive Energy QIV - Total (kvarh) - previous period x x x40548 FLOAT Sum Li Reactive power QIV - Tariff * 4x x x40550 FLOAT Sum Li Reactive power QIV - Tariff 1 - previous period x x x40552 FLOAT Sum Li Reactive power QIV - Tariff * 4x x x40554 FLOAT Sum Li Reactive power QIV - Tariff 2 - previous period x x x40556 FLOAT Sum Li Reactive power QIV - Tariff * 4x x x40558 FLOAT Sum Li Reactive power QIV - Tariff 3 - previous period x x x40560 FLOAT L1 Current; Inst.value x x x40562 FLOAT L2 Current; Inst.value x x x40564 FLOAT L3 Current; Inst.value x x x40566 FLOAT L1 Voltage; Inst.value x x x40568 FLOAT L2 Voltage; Inst.value x x x40570 FLOAT L3 Voltage; Inst.value x x x40572 FLOAT Supply frequency x x x40574 FLOAT L1 Power factor; Inst.value x x x40576 FLOAT L2 Power factor; Inst.value x x x40578 FLOAT L3 Power factor; Inst.value x x x40580 FLOAT Angle of U(L1) - I(L1) x x x40582 FLOAT Angle of U(L2) - I(L2) x x x40584 FLOAT Angle of U(L3) - I(L3) User s Manual GW-DLMS-485-ISK Page 11

13 Some systems have problem with float number, so we have created a copy of total energy counter in UNSIGNED LONG format in the following different MODBUS area: METER 1 METER 2 METER x x x41126 ULONG Active Energy - Import - Total (kwh) * 4x x x41128 ULONG Active Energy - Import - Total (kwh) - previous period x x x41130 ULONG Active Energy - Export - Total (kwh) * 4x x x41132 ULONG Active Energy - Export - Total (kwh) - previous period x x x41134 ULONG Reactive Energy QI - Total (kvarh) * 4x x x41136 ULONG Reactive Energy QI - Total (kvarh) - previous period x x x41138 ULONG Reactive Energy QII - Total (kvarh) * 4x x x41140 ULONG Reactive Energy QII - Total (kvarh) - previous period x x x41142 ULONG Reactive Energy QIII - Total (kvarh) * 4x x x41144 ULONG Reactive Energy QIII - Total (kvarh) - previous period x x x41146 ULONG Reactive Energy QIV - Total (kvarh) * 4x x x41148 ULONG Reactive Energy QIV - Total (kvarh) - previous period User s Manual GW-DLMS-485-ISK Page 12

14 3.0 Communication errros 3.0 COMMUNICATION ERRORS 3.1 Type of error Errors in modbus address 4x40014 are formed by 2 digits: AB. A : this indicates which energy meter is reported B : this indicates the type of error 5 : serial port is not correctly opened 7 : message from energy meter is too big for gateway s buffer; this error does not compromise gateway s normal functionality, but last part of obis list will be lost 8 : message from energy meter is empty -> please check cable connection There are also : 888 : global timeout error (this happens if there aren t meter s serial number in modbus area) 999 : hardware/software authenticity error User s Manual GW-DLMS-485-ISK Page 13

15 7.0 Mechanical features 4.0 MECHANICAL FEATURES The size of the gateway are the following: User s Manual GW-DLMS-485-ISK Page 14

Datalogger web contaimpulsi

Datalogger web contaimpulsi Datalogger web contaimpulsi Versione 6 ingressi con Ethernet (GW-IMP-WEB-1) 1 Datalogger web conta impulsi Il datalogger web conta impulsi è in grado di conteggiare gli impulsi sugli ingressi digitali

Dettagli

Gateway RS485 DLMS-MODBUS. Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP

Gateway RS485 DLMS-MODBUS. Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP Gateway RS485 DLMS-MODBUS Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP Gateway RS485 DLMS-MODBUS Il Protocollo DLSM (Device Language Message Specification) viene utilizzato nell'ambito

Dettagli

Guida rapida di installazione

Guida rapida di installazione Configurazione 1) Collegare il Router Hamlet HRDSL108 Wireless ADSL2+ come mostrato in figura:. Router ADSL2+ Wireless Super G 108 Mbit Guida rapida di installazione Informiamo che il prodotto è stato

Dettagli

User Guide Guglielmo SmartClient

User Guide Guglielmo SmartClient User Guide Guglielmo SmartClient User Guide - Guglielmo SmartClient Version: 1.0 Guglielmo All rights reserved. All trademarks and logos referenced herein belong to their respective companies. -2- 1. Introduction

Dettagli

WELCOME. Go to the link of the official University of Palermo web site www.unipa.it; Click on the box on the right side Login unico

WELCOME. Go to the link of the official University of Palermo web site www.unipa.it; Click on the box on the right side Login unico WELCOME This is a Step by Step Guide that will help you to register as an Exchange for study student to the University of Palermo. Please, read carefully this guide and prepare all required data and documents.

Dettagli

Guida alla configurazione Configuration Guide

Guida alla configurazione Configuration Guide Guida alla configurazione Configuration Guide Configurazione telecamere IP con DVR analogici, compatibili IP IP cameras configuration with analog DVR, IP compatible Menu principale: Fare clic con il pulsante

Dettagli

CONFIGURATION MANUAL

CONFIGURATION MANUAL RELAY PROTOCOL CONFIGURATION TYPE CONFIGURATION MANUAL Copyright 2010 Data 18.06.2013 Rev. 1 Pag. 1 of 15 1. ENG General connection information for the IEC 61850 board 3 2. ENG Steps to retrieve and connect

Dettagli

CCTV DIVISION GUIDA RAPIDA PER LA CONFIGURAZIONE DELL IP STATICO SU SISTEMI TVCC QUICK GUIDE FOR STATIC IP CONFIGURATION ABOUT CCTV SYSTEM

CCTV DIVISION GUIDA RAPIDA PER LA CONFIGURAZIONE DELL IP STATICO SU SISTEMI TVCC QUICK GUIDE FOR STATIC IP CONFIGURATION ABOUT CCTV SYSTEM CCTV DIVISION GUIDA RAPIDA PER LA CONFIGURAZIONE DELL IP STATICO SU SISTEMI TVCC QUICK GUIDE FOR STATIC IP CONFIGURATION ABOUT CCTV SYSTEM ITALIANO Principali Step per la configurazione I dispositivi di

Dettagli

Guida utente User Manual made in Italy Rev0

Guida utente User Manual made in Italy Rev0 Guida utente User Manual Rev0 made in Italy Indice/Index Informazioni generali General Info... 3 Guida Rapida per messa in funzione Start Up procedure... 3 Login Login... 3 Significato dei tasti Botton

Dettagli

Convertitore di protocollo IEC 62056-21 / Modbus RTU Per contatori ELSTER A1700i. Manuale utente e protocol mapping

Convertitore di protocollo IEC 62056-21 / Modbus RTU Per contatori ELSTER A1700i. Manuale utente e protocol mapping POWERCOM 2 Convertitore di protocollo IEC 62056-21 / Modbus RTU Per contatori ELSTER A1700i Revisione : 0 Data : Novembre 2012 Software POWERCOM2 : 1007 Firmware contatore : Enel Pagina 1 di 9 1. Presentazione

Dettagli

EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP.

EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP. MANUALE ISTRUZIONI IM471-I v0.2 EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP. Transmission Control

Dettagli

STE04WS MANUALE UTENTE V. 1.0

STE04WS MANUALE UTENTE V. 1.0 STE04WS MANUALE UTENTE V. 1.0 INDICE 1 DICHIARAZIONE DI CONFORMITÀ 3 2 INTRODUZIONE 3 3 CARATTERISTICHE TECNICHE 3 3.1 PROTOCOLLI SUPPORTATI 3 3.2 CONNESSIONE ALLA RETE ETHERNET 3 3.3 PORTA SERIALE 3 3.4

Dettagli

LINKSYS SPA922 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

LINKSYS SPA922 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP LINKSYS SPA922 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Linksys SPA922 - Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 COLLEGAMENTO FISICO APPARATO...3 ACCESSO ALL ADMINISTRATOR WEB

Dettagli

ATA-172 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

ATA-172 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-172 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-172 Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 SCHEMA DI COLLEGAMENTO...3 ACCESSO ALL APPARATO...4 CONFIGURAZIONE EUTELIAVOIP...7

Dettagli

ELSTER A1700i. Manuale software di lettura Dati Power Master Unit Read Olny. Contatore ELSTER A1700i. Manuale software di lettura dati PMU Read Olny

ELSTER A1700i. Manuale software di lettura Dati Power Master Unit Read Olny. Contatore ELSTER A1700i. Manuale software di lettura dati PMU Read Olny ELSTER A1700i Manuale software di lettura Dati Power Master Unit Read Olny Revisione : 0 Data : Aprile 2011 Software : Power Master Unit Read only 2.4 Firmware : Enel Pagina 1 di 20 1. Presentazione del

Dettagli

PIRELLI Discus NetGate VoIP v2 VOIP ADSL ROUTER GUIDA ALL INSTALLAZIONE

PIRELLI Discus NetGate VoIP v2 VOIP ADSL ROUTER GUIDA ALL INSTALLAZIONE VoIP ADSL Router Discus NetGate VoIP v2 Pirelli (0.56S) Manuale operativo Pag. 1 PIRELLI Discus NetGate VoIP v2 VOIP ADSL ROUTER GUIDA ALL INSTALLAZIONE Release 0.56S VoIP ADSL Router Discus NetGate VoIP

Dettagli

Contatori CEWEPrometer R/W Convertitore di protocollo IEC 62056-21 (IEC1107) / Modbus RTU CEWEMod MANUALE DI CONFIGURAZIONE

Contatori CEWEPrometer R/W Convertitore di protocollo IEC 62056-21 (IEC1107) / Modbus RTU CEWEMod MANUALE DI CONFIGURAZIONE Tecniche di misura e Automazione Staer S.r.l. Uffici Via Sibilla Aleramo,4 20090 Segrate (MI) Tel. 02/26952067 Fax. 02/26922849 info@staermisure.it www.staermisure.it Sede legale Via Buonarroti, 3 20050

Dettagli

PIRELLI DISCUS NETGATE VoIP v2 GUIDA ALL INSTALLAZIONE. Pirelli Discus Netgate Guida all installazione EUTELIAVOIP Rev1-0

PIRELLI DISCUS NETGATE VoIP v2 GUIDA ALL INSTALLAZIONE. Pirelli Discus Netgate Guida all installazione EUTELIAVOIP Rev1-0 PIRELLI DISCUS NETGATE VoIP v2 GUIDA ALL INSTALLAZIONE Pirelli Discus Netgate Guida all installazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA...3 COLLEGAMENTO

Dettagli

REGISTRATION GUIDE TO RESHELL SOFTWARE

REGISTRATION GUIDE TO RESHELL SOFTWARE REGISTRATION GUIDE TO RESHELL SOFTWARE INDEX: 1. GENERAL INFORMATION 2. REGISTRATION GUIDE 1. GENERAL INFORMATION This guide contains the correct procedure for entering the software page http://software.roenest.com/

Dettagli

IP 500 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

IP 500 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP 500 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP Phone - Perfectone IP 500 - Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP500...3

Dettagli

DEXGATE 3000 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

DEXGATE 3000 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP DEXGATE 3000 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP PHONE - DEXGATE 3000 Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 ACCESSO ALLA USER INTERFACE...3 CONFIGURAZIONE EUTELIAVOIP

Dettagli

I N T E G R A S. R. L. Via Lecco, 5/E - 22036 Erba (CO) - ITALY Tel/Fax: +39-031 3338884 P.I. 02608090136 N CCIAA 269444 MANUALE UTENTE T-MOD

I N T E G R A S. R. L. Via Lecco, 5/E - 22036 Erba (CO) - ITALY Tel/Fax: +39-031 3338884 P.I. 02608090136 N CCIAA 269444 MANUALE UTENTE T-MOD Via Lecco, 5/E - 22036 Erba (CO) - ITALY Tel/Fax: +39-031 3338884 P.I. 02608090136 N CCIAA 269444 UNI EN ISO 9001:2008 CERT. N. 50 100 6048 Controllo ambientale integrato MANUALE UTENTE T-MOD Rev. Data

Dettagli

Posta elettronica per gli studenti Email for the students

Posta elettronica per gli studenti Email for the students http://www.uninettunouniverstiy.net Posta elettronica per gli studenti Email for the students Ver. 1.0 Ultimo aggiornamento (last update): 10/09/2008 13.47 Informazioni sul Documento / Information on the

Dettagli

SIP-Phone 302 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

SIP-Phone 302 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIP-Phone 302 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIP-Phone 302 Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 COME ACCEDERE ALLA CONFIGURAZIONE...3 Accesso all IP Phone quando il

Dettagli

How to use the WPA2 encrypted connection

How to use the WPA2 encrypted connection How to use the WPA2 encrypted connection At every Alohawifi hotspot you can use the WPA2 Enterprise encrypted connection (the highest security standard for wireless networks nowadays available) simply

Dettagli

MC-link Spa. Pannello frontale del Vigor2700e. Installazione hardware del Vigor2700e

MC-link Spa. Pannello frontale del Vigor2700e. Installazione hardware del Vigor2700e MC-link Spa Pannello frontale del Vigor2700e Installazione hardware del Vigor2700e Questa sezione illustrerà come installare il router attraverso i vari collegamenti hardware e come configurarlo attraverso

Dettagli

CPE Telsey Manuale d uso per utenti

CPE Telsey Manuale d uso per utenti Indice 1. ACCESSO ALLA CPE------------------------------------------------------------------------------ 3 2. DEVICE INFO ----------------------------------------------------------------------------------------

Dettagli

Configurazione WAN (accesso internet)

Configurazione WAN (accesso internet) D-Link G624T Per entrare nella configurazione del Router è necessario collegarlo tramite porta Ethernet (di rete). Nelle opzioni di configurazione della scheda di rete, in Protocollo TCP/IP lasciare l

Dettagli

Manuale utente. Quinx Box serie 200/300/400. Ethernet RS232 - TCP/IP converter

Manuale utente. Quinx Box serie 200/300/400. Ethernet RS232 - TCP/IP converter Manuale utente Quinx Box serie 200/300/400 Ethernet RS232 - TCP/IP converter A cura di: ICG Holding srl Div. Time & Access Via Leonardo da Vinci 45/47 20020 Lainate (MI) Nr. rif. Q 200 001 Versione 1.10.97

Dettagli

IF2E001 Interfaccia Ethernet-RS485

IF2E001 Interfaccia Ethernet-RS485 IF2E001 Interfaccia Ethernet-RS485 Manuale utente File : Ethernet interfaccia-manuale utente.doc 1/4 Interfaccia Ethernet manuale utente Versione 1.1 1 DESCRIZIONE GENERALE Questo dispositivo consente

Dettagli

Guida all utilizzo del modulo MPI BrainChild

Guida all utilizzo del modulo MPI BrainChild Document version: 1.0 easitec S.r.l. Viale Martiri della Benedicta, 102 15069 Serravalle Scrivia (AL) - Italy Phone +39.0143.686023 - Fax +39.0143.634777 info@easitec.it - www.easitec.it Revision History

Dettagli

Wireless ADSL VPN Firewall Router

Wireless ADSL VPN Firewall Router Wireless ADSL VPN Firewall Router GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:

Dettagli

SIP PHONE Perfectone IP301 Manuale Operativo PHONE IP301 GUIDA ALL INSTALLAZIONE

SIP PHONE Perfectone IP301 Manuale Operativo PHONE IP301 GUIDA ALL INSTALLAZIONE pag.1 PHONE IP301 GUIDA ALL INSTALLAZIONE pag.2 INDICE SERVIZIO VOIP SKYPHO...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP301...3 COLLEGAMENTO FISICO APPARATO...4 ACCESSO ALL APPARATO...8 Accesso all IP

Dettagli

Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender N 300Mbps TL-WA850RE

Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender N 300Mbps TL-WA850RE Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender N 300Mbps TL-WA850RE È possibile usare questo metodo solo se il vostro Router o Access Point (AP) supporta WPS. 1. Accensione 3. Riposizionamento

Dettagli

INSTALLARE PALLADIO USB DATA CABLE IN WINDOWS XP/ME/2000/98

INSTALLARE PALLADIO USB DATA CABLE IN WINDOWS XP/ME/2000/98 rev. 1.0-02/2002 Palladio USB Data Cable INSTALLARE PALLADIO USB DATA CABLE IN WINDOWS XP/ME/2000/98 (tutti i KIT, escluso KIT MOTOROLA V6x-T280) La procedura di installazione del Palladio USB Data Cable

Dettagli

ZyXEL Prestige 2602R GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

ZyXEL Prestige 2602R GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ZyXEL Prestige 2602R GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ZyXEL Prestige 2602R-61 Guida alla configurazione EUTELIAVOIP pag.2 INDICE SCOPO...3 ACCESSO ALLA USER INTERFACE...3 CONFIGURAZIONE EUTELIAVOIP

Dettagli

Copyright 2012 Binary System srl 29122 Piacenza ITALIA Via Coppalati, 6 P.IVA 01614510335 - info@binarysystem.eu http://www.binarysystem.

Copyright 2012 Binary System srl 29122 Piacenza ITALIA Via Coppalati, 6 P.IVA 01614510335 - info@binarysystem.eu http://www.binarysystem. CRWM CRWM (Web Content Relationship Management) has the main features for managing customer relationships from the first contact to after sales. The main functions of the application include: managing

Dettagli

Laboratorio di Amministrazione di Sistema (CT0157) parte A : domande a risposta multipla

Laboratorio di Amministrazione di Sistema (CT0157) parte A : domande a risposta multipla Laboratorio di Amministrazione di Sistema (CT0157) parte A : domande a risposta multipla 1. Which are three reasons a company may choose Linux over Windows as an operating system? (Choose three.)? a) It

Dettagli

Metodo 1: Quick Setup tramite tasto WPS

Metodo 1: Quick Setup tramite tasto WPS Metodo 1: Quick Setup tramite tasto WPS Pocket Range Extender RE200 AC750 Si può usare questo metodo solo se il vostro Router o Access Point(AP) supporta WPS. 1. Accensione 2. Premete i 2 pulsanti WPS

Dettagli

LINKSYS WRTP54G GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

LINKSYS WRTP54G GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP LINKSYS WRTP54G GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Linksys WRTP54G Guida alla configurazione EuteliaVoip Rev1-0 pag.2 INDICE SCOPO...3 ACCESSO ALLA USER INTERFACE...3 CONFIGURAZIONE VIA WEB BROWSER...5

Dettagli

Unità di telelettura per contatori

Unità di telelettura per contatori Unità di telelettura per contatori Funzionalità : 5 Ingressi digitali, per segnali GME (ingresso S0) 1 Uscita digitale, per segnalazione di allarme seriale RS232 o RS485, protocolli ModBus o DLMS per comunicazione

Dettagli

I-Fly Wireless Broadband Router

I-Fly Wireless Broadband Router with 4 Fast Ethernet ports + 1 Wan port Guida Rapida A02-WR-54G/G1 (Novembre 2003)V1.00 Questo manuale è inteso come una guida rapida, pertanto per ulteriori dettagli sulla configurazione fare riferimento

Dettagli

D-Link DVG-2001S GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

D-Link DVG-2001S GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP D-Link DVG-2001S GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP DWG-2001S D-Link Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 CONFIGURAZIONE WEB...3 Impostazione NTP Server...4 SIP CONFIGURATION...5

Dettagli

Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software

Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software Windows 7 Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software Contenuto del kit cod. 20046946: - Interfaccia PC-scheda (comprensiva

Dettagli

CONFIGURAZIONE VIA WEB BROWSER

CONFIGURAZIONE VIA WEB BROWSER CONFIGURAZIONE VIA WEB BROWSER Prima di procedere con la configurazione del vostro Pirelli NetGate VoIP via WEB Browser è importante che vi assicuriate di avere a disposizione i dati della connessione

Dettagli

SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Gigaset S450 IP Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 TELEFONARE CON EUTELIAVOIP...3 CONNESSIONE DEL TELEFONO

Dettagli

RS 485 PER INTERFACCIARE IL PC. DISPLAY, Visualizza, A, V, Hz,P.

RS 485 PER INTERFACCIARE IL PC. DISPLAY, Visualizza, A, V, Hz,P. STRUMENTO MULTIFUNZIONE MONOFASE Lo strumento in questione occupa 1 DIN (18 mm) e si alloggia facilmente in un normale quadretto, anche di tipo casalingo, che abbia la guida DIN, lo strumento va installato

Dettagli

DICHIARAZIONE DI RESPONSABILITÀ

DICHIARAZIONE DI RESPONSABILITÀ - 0MNSWK0082LUA - - ITALIANO - DICHIARAZIONE DI RESPONSABILITÀ Il produttore non accetta responsabilità per la perdita di dati, produttività, dispositivi o qualunque altro danno o costo associato (diretto

Dettagli

Metodo 1: Quick Setup tramite tasto WPS Range Extender RE210 AC750

Metodo 1: Quick Setup tramite tasto WPS Range Extender RE210 AC750 Metodo 1: Quick Setup tramite tasto WPS Range Extender RE210 AC750 Si può usare questo metodo solo se il vostro Router o Access Point(AP) supporta WPS. 1. Accensione 2. Premete i 2 pulsanti WPS r 3. Riposizionamento

Dettagli

Plugin Single Sign-On

Plugin Single Sign-On NEXT-GEN USG Plugin Single Sign-On Configurazione Agent SSO su AD Verificare di avere l ultima release del client SSO installato su Windows Server. AL momento di redigere la guida la più recente è la 1.0.3

Dettagli

FRITZ!Box Fon ata GUIDA ALL INSTALLAZIONE. Fritz!Box Fon ATA Guida all installazione EUTELIAVOIP Rev1-0

FRITZ!Box Fon ata GUIDA ALL INSTALLAZIONE. Fritz!Box Fon ATA Guida all installazione EUTELIAVOIP Rev1-0 FRITZ!Box Fon ata GUIDA ALL INSTALLAZIONE Fritz!Box Fon ATA Guida all installazione EUTELIAVOIP Rev1-0 pag.2 INDICE BREVE DESCRIZIONE DEL FRITZ!Box Fon ata...3 IL CONTENUTO DELLA SCATOLA DEL FRITZ!Box

Dettagli

IP 301 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

IP 301 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP 301 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP PHONE Perfectone IP301 Guida alla Configurazione EUTELIAVOIP Rev1-1 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP301...3

Dettagli

IP 300 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

IP 300 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP 300 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP PHONE Perfectone IP300 Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DELL IP300...3

Dettagli

Soluzioni per l energia solare Solutions for solar energy

Soluzioni per l energia solare Solutions for solar energy Multi MPPT 270V RPS TL 0280 0340 0510 0680 0850 kwp 280 340 510 680 850 Corrente di ingresso max. / Max. input current A 600 700 1050 1400 1750 Intervallo MPPT / MPPT range V 425... 875 N. MPPT 2 2 3 4

Dettagli

MC-link Spa Collegamento e configurazione del router Vigor2800i per l accesso ad MC-link

MC-link Spa Collegamento e configurazione del router Vigor2800i per l accesso ad MC-link MC-link Spa Collegamento e configurazione del router Vigor2800i per l accesso ad MC-link Pannello frontale del Vigor2800i Installazione hardware del Vigor2800i Questa sezione illustrerà come installare

Dettagli

GLOBAL IP G300 SIP PHONE GUIDA ALL INSTALLAZIONE

GLOBAL IP G300 SIP PHONE GUIDA ALL INSTALLAZIONE pag.1 GLOBAL IP G300 SIP PHONE GUIDA ALL INSTALLAZIONE pag.2 INDICE SERVIZIO VOIP SKYPHO...3 COMPONENTI PRESENTI NELLA SCATOLA DEL G300...3 COLLEGAMENTO FISICO APPARATO...4 ACCESSO ALL'APPARATO...7 Accesso

Dettagli

Guida alla installazione ed alla programmazione della Interfaccia Universale ATS1806

Guida alla installazione ed alla programmazione della Interfaccia Universale ATS1806 Guida alla installazione ed alla programmazione della Interfaccia Universale ATS1806 Scopo: Fornire le informazioni necessarie per l installazione e la programmazione della scheda Interfaccia Universale

Dettagli

CPE Zhone Manuale d uso per utenti

CPE Zhone Manuale d uso per utenti Indice 1. ACCESSO ALLA CPE------------------------------------------------------------------------------ 3 2. STATUS ------------------------------------------------------------------------------------------------

Dettagli

Guida all installazione rapida

Guida all installazione rapida Italian 1. Guida all installazione rapida Requisiti del sistema Il PC deve essere attrezzato con quanto segue per configurare Thecus YES Box N2100: Unità CD-ROM o DVD-ROM Porta Ethernet collegata ad un

Dettagli

Manuale Utente Rev. 0.3 del 26/11/2004

Manuale Utente Rev. 0.3 del 26/11/2004 Manuale Utente Rev. 0. del 6//00 Menu di runtime 5 6.Menu di Run-time File - Exit: Termina l esecuzione del programma Run - Start: Avvia il monitoraggio degli inverter indicati nella Inverter List - Stop:

Dettagli

Rev. 2.00.0 NGS FRAMEWORK

Rev. 2.00.0 NGS FRAMEWORK www.promax.it Le informazioni contenute nel manuale sono solo a scopo informativo e possono subire variazioni senza preavviso e non devono essere intese con alcun impegno da parte di Promax srl. Promax

Dettagli

EuteliaVoIP. Troubleshooting IP301

EuteliaVoIP. Troubleshooting IP301 EuteliaVoIP Troubleshooting IP301 1 Indice contenuti IP 301 Firmware Rev L da pag.3 a 11 IP 301 Firmware Rev U da pag. 12 a 20 IP 301 PortForwarding da pag. 21 a 25 IP 301 Configurazione da tastiera pag.26

Dettagli

SIEMENS GIGASET C450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

SIEMENS GIGASET C450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIEMENS GIGASET C450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Gigaset C450 IP Guida alla configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 TELEFONARE CON EUTELIAVOIP...3 CONNESSIONE DEL TELEFONO

Dettagli

ATA-G81022MS GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

ATA-G81022MS GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-G81022MS GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP ATA-G81022MS Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SCOPO...3 SCHEMA DI COLLEGAMENTO...3 ACCESSO ALL APPARATO...4 CONFIGURAZIONE EUTELIAVOIP...7

Dettagli

TW100-S4W1CA Router a Banda Larga (con un interruttore a 4-porte) (ver.e) Guida all installazione rapida

TW100-S4W1CA Router a Banda Larga (con un interruttore a 4-porte) (ver.e) Guida all installazione rapida TW100-S4W1CA Router a Banda Larga (con un interruttore a 4-porte) (ver.e) Guida all installazione rapida QIG-SS07232003 FASE 1: CONNETTERE I DISPOSITIVI Figura 1 ** Accendere il proprio Modem DSL/a cavo.

Dettagli

WLAN660 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

WLAN660 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP WLAN660 GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP IP PHONE Wi-Fi VoIP 660 Guida alla Configurazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DEL WLAN660...3

Dettagli

Configurazione modalità autenticazione utenti sui firewall D-Link Serie NetDefend (DFL-200, DFL-700, DFL-1100)

Configurazione modalità autenticazione utenti sui firewall D-Link Serie NetDefend (DFL-200, DFL-700, DFL-1100) Configurazione modalità autenticazione utenti sui firewall D-Link Serie NetDefend (DFL-200, DFL-700, DFL-1100) Pagina 1 di 10 Per abilitare la modalità di autenticazione degli utenti occorre, prima di

Dettagli

Router Firewall 802.11g ADSL VPN

Router Firewall 802.11g ADSL VPN Router Firewall 802.11g ADSL VPN GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com 1 NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:

Dettagli

Compatibilità del Portale Piaggio con Internet Explorer 10 e 11. Internet Explorer 10

Compatibilità del Portale Piaggio con Internet Explorer 10 e 11. Internet Explorer 10 Italiano: Explorer 10 pagina 1, Explorer 11 pagina 2 English: Explorer 10 page 3 and 4, Explorer 11 page 5. Compatibilità del Portale Piaggio con Internet Explorer 10 e 11 Internet Explorer 10 Con l introduzione

Dettagli

SSO Specifiche Funzionali

SSO Specifiche Funzionali SSO Specifiche Funzionali oggetto... : SSO Siti Istituzionali Class abbonamenti data ultimo aggiornamento... : 29/01/2014 N Data Descrizione Approvato da: 1.0 11-03-2013 Versione 1.0 Roberto Santosuosso

Dettagli

Percorso Formativo SAP per IMPIEGATO SAP TECNICO-INFORMATICO Programmazione-Analisi- Progetti

Percorso Formativo SAP per IMPIEGATO SAP TECNICO-INFORMATICO Programmazione-Analisi- Progetti Percorso Formativo SAP per IMPIEGATO SAP TECNICO-INFORMATICO Programmazione-Analisi- Progetti Introduzione ad ABAP/4 Programma report Programma interattivo Tabelle SAP Smartforms SAP Query Navigazione

Dettagli

ROUTER ADSL2 FIREWALL WIRELESS

ROUTER ADSL2 FIREWALL WIRELESS ROUTER ADSL2 FIREWALL WIRELESS GUIDA RAPIDA DI INSTALLAZIONE www.hamletcom.com 1 NB: Per avere istruzioni dettagliate per configurare e usare il Router, utilizzare il manuale on-line. Prestare attenzione:

Dettagli

Attuatore a relè Manuale di istruzioni

Attuatore a relè Manuale di istruzioni Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per

Dettagli

Mediatrix 3000 & Asterisk

Mediatrix 3000 & Asterisk Mediatrix 3000 & Asterisk Release Date: Febbraio 2013 1 / 34 Questo manuale è rilasciato con la licenza Creative Commons Attribution-NonCommercial-NoDerivs 2.5, consultabile all indirizzo http://creativecommons.org.

Dettagli

Posta Elettronica Certificata

Posta Elettronica Certificata Stato: Rilasciato Posta Elettronica Certificata elettronica per il servizio PEC di IT Telecom Documento ad uso pubblico Pag. 1 di 30 Stato: Rilasciato REGISTRO DELLE MODIFICHE REVISIONE DESCRIZIONE EMISSIONE

Dettagli

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

RPS TL System. Soluzioni per l energia solare Solutions for solar energy Soluzioni per l energia solare Solutions for solar energy RPS TL da 280 kwp a 1460 kwp RPS TL from 280 kwp to 1460 kwp RPS TL System L elevata affidabilità e la modularità della costruzione sono solo alcuni

Dettagli

PANEL EXPRESS. KITE automation srl - Via Morandi 10-20077 Melegnano (MI) - Tel/Fax +39 02/39.62.44.34 - support@kite-automation.it

PANEL EXPRESS. KITE automation srl - Via Morandi 10-20077 Melegnano (MI) - Tel/Fax +39 02/39.62.44.34 - support@kite-automation.it PANEL EXPRESS PanelExpress è un software runtime per HMI basato su piattaforma Windows XP e.net. Il software permette di utilizzare le risorse di un ipc (p.e. la potenza di calcolo, multimedia, grande

Dettagli

Prima di iniziare la procedura d installazione, verificare che siano disponibili tutte le informazioni e le attrezzature necessarie

Prima di iniziare la procedura d installazione, verificare che siano disponibili tutte le informazioni e le attrezzature necessarie Il presente prodotto può essere configurato con un browser web aggiornato come Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-504T ADSL Router Prima di cominciare Prima di iniziare la procedura d

Dettagli

SYSTEM MANUAL SM_0007.1 ESEMPI INTEGRAZIONE PRODOTTI. Teleassistenza Twido-Suite & Twido

SYSTEM MANUAL SM_0007.1 ESEMPI INTEGRAZIONE PRODOTTI. Teleassistenza Twido-Suite & Twido SYSTEM MANUAL ESEMPI INTEGRAZIONE PRODOTTI Teleassistenza Twido-Suite & Twido SM_0007.1 Si realizza una connessione remota con l ausilio dell Internet Protocol Suite, di cui in particolare i protocolli

Dettagli

ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE

ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE ATA MEDIATRIX 2102 GUIDA ALL INSTALLAZIONE Mediatrix 2102 ATA Guida all installazione EUTELIAVOIP Rev1-0 pag.2 INDICE SERVIZIO EUTELIAVOIP...3 COMPONENTI PRESENTI NELLA SCATOLA DEL MEDIATRIX 2102...3 COLLEGAMENTO

Dettagli

GIGASET SL75 WLAN GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

GIGASET SL75 WLAN GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP GIGASET SL75 WLAN GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Gigaset SL75 WLAN Guida alla configurazione EUTELIAVOIP pag.2 INDICE SCOPO...3 CONNESSIONE DEL TELEFONO SL75 WLAN...3 Prerequisiti necessari Access

Dettagli

Guida rapida Quick guide 46DVR.504-46DVR.508

Guida rapida Quick guide 46DVR.504-46DVR.508 Guida rapida Quick guide 46DVR.504-46DVR.508 DVR con tecnologia AHD a 4/8 canali in tempo reale e HDD 1TB DVR AHD realtime 4/8 channel HDD 1TB 1 Descrizione 1.1 Descrizione del pannello anteriore Avvertenza:

Dettagli

Connessione e configurazione del modem/router US ROBOTICS SURECONNECT ADSL 4-PORT per l accesso a TELE2Internet ADSL

Connessione e configurazione del modem/router US ROBOTICS SURECONNECT ADSL 4-PORT per l accesso a TELE2Internet ADSL Connessione e configurazione del modem/router US ROBOTICS SURECONNECT ADSL 4-PORT per l accesso a TELE2Internet ADSL I requisiti necessari per l'installazione sono: - Windows 98 SE, Windows 2000, WinME,

Dettagli

MANUALE UTENTE MODULO ESPANSIONE TASTI MANUALE UTENTE MANUALE UTENTE Descrizione Il modulo fornisce al telefono VOIspeed V-605 flessibilità e adattabilità, mediante l aggiunta di trenta tasti memoria facilmente

Dettagli

Smart Guide ITALIANO. Versione: 3.2.5. netrd. etstart srl via Austria, 23/D - 35127 Padova (PD), Italy - info@etstart.it - www.etstart.

Smart Guide ITALIANO. Versione: 3.2.5. netrd. etstart srl via Austria, 23/D - 35127 Padova (PD), Italy - info@etstart.it - www.etstart. Smart Guide netrd ITALIANO Versione: 3.2.5 netrd è commercializzato da etstart srl via Austria, 23/D - 35127 Padova (PD), Italy - info@etstart.it - www.etstart.it 1 1 Descrizione Prodotto INDICE 1.1 Informazioni

Dettagli

SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Gigaset S450 IP Guida alla configurazione EUTELIAVOIP Rev2-0 pag.2 INDICE SCOPO...3 TELEFONARE CON EUTELIAVOIP...3 CONNESSIONE DEL TELEFONO

Dettagli

Via Maria 122, 03100 FROSINONE www.hellotel.it info@hellotel.it. MANUALE di INSTALLAZIONE e CONFIGURAZIONE INTERNET ADSL Wi-Fi

Via Maria 122, 03100 FROSINONE www.hellotel.it info@hellotel.it. MANUALE di INSTALLAZIONE e CONFIGURAZIONE INTERNET ADSL Wi-Fi Via Maria 122, 03100 FROSINONE www.hellotel.it info@hellotel.it MANUALE di INSTALLAZIONE e CONFIGURAZIONE INTERNET ADSL Wi-Fi versione 2.0 del 24/02/2009 1. Antenna OsBridge 1.1 Configurazione preliminare

Dettagli

DSL-G604T Wireless ADSL Router

DSL-G604T Wireless ADSL Router Il prodotto può essere configurato con un qualunque browser aggiornato come Internet Explorer 6 o Netscape Navigator 6.2.3. DSL-G604T Wireless ADSL Router Prima di cominciare 1. Se si intende utilizzare

Dettagli

MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS

MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS COMPATIBILE CON - COMPATIBLE WITH LP14/20/30 SCHEDA - MOTHERBOARD 512 E SW V5 2 IT COLLEGAMENTO A MURO DELLA CONSOLE LCD - CALDAIA Collegamento

Dettagli

Estensore su CAT5 per VGA, USB, AUDIO, RS232 E IR MODELLO: VKM03

Estensore su CAT5 per VGA, USB, AUDIO, RS232 E IR MODELLO: VKM03 Estensore su CAT5 per VGA, USB, AUDIO, RS232 E IR MODELLO: VKM03 Il VKM03 è un estensore su cavo CAT5 per: VGA, USB con audio stereo, RS232, e IR. Questo dispositivo permette distanze di trasmissione fino

Dettagli

SIEMENS GIGASET S685 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

SIEMENS GIGASET S685 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP SIEMENS GIGASET S685 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP Gigaset S685 IP Guida alla configurazione EUTELIAVOIP Rev2-0 pag.2 INDICE SCOPO... 3 TELEFONARE CON EUTELIAVOIP... 3 CONNESSIONE DEL TELEFONO

Dettagli

Employee Letter. Manuale DatabICS

Employee Letter. Manuale DatabICS Employee Letter Manuale DatabICS Manuale DatabICS 22023799 Versione 1.0 12.10.2012 Andreas Merz 1.1 29.10.2012 Andreas Merz 1.2 06.11.2012 Andreas Merz 1.3 08.11.2012 Andreas Merz 1.4 19.02.2013 Andreas

Dettagli

ATTENZIONE Prima di collegare l alimentazione inserire la SD CARD che si trova dentro alla scatola (vedi istruzioni all interno)

ATTENZIONE Prima di collegare l alimentazione inserire la SD CARD che si trova dentro alla scatola (vedi istruzioni all interno) ATTENZIONE Prima di collegare l alimentazione inserire la SD CARD che si trova dentro alla scatola (vedi istruzioni all interno) Importante Per una corretta installazione del prodotto è necessario seguire

Dettagli

VIPA 900-2E641 PSTN VPN

VIPA 900-2E641 PSTN VPN CONFIGURARE IL DISPOSITIVO DI TELEASSISTENZA VIPA 900-2E641 PSTN VPN Requisiti hardware: Dispositivo VIPA 900-2E641 PSTN VPN con versione di firmware almeno 6_1_s2. Cavo telefonico e linea analogica. Requisiti

Dettagli

User-Defined contenuto del display, Soluzione dimostrazione solare

User-Defined contenuto del display, Soluzione dimostrazione solare www.geoprotek.com SUPPORTED INVERTERS: ABB AEI KACO POWER-ONE XANTREX SATCON DELTA PHOENIXTEC EATON SCHNEIDER KLNE MOTECH POWERCOM ABLEREX GEOPROTEK POWER GENERAL GS YUASA User-Defined contenuto del display,

Dettagli

Problemi Una descrizione dei problemi sorti durante le fasi di

Problemi Una descrizione dei problemi sorti durante le fasi di Etichetta del test case Composta da: - DUT : Device Under Test; - Numero/i incrementale/i: per identificare la gerarchia di appartenenza; - Tipologia: TP (throughput), LT (latenza), FL (Frame Loss); -

Dettagli

IMPORTANTE : La XM200LAN non può essere utilizzata contemporaneamente da più computer. Tasto RESET

IMPORTANTE : La XM200LAN non può essere utilizzata contemporaneamente da più computer. Tasto RESET XM200LN Made in Italy EMC/2006/95/CE zienda con Sistema di gestione per la Qualità UNI EN ISO 9001:2000 Lead free Pb RoHS compliant REE Modulo connessione LN per centrali Serie XM Tensione nominale di

Dettagli

CD-ROM (contiene Manual y garantía) Cavo Ethernet (CAT5 UTP/diritto) Cavo Console (RS-232)

CD-ROM (contiene Manual y garantía) Cavo Ethernet (CAT5 UTP/diritto) Cavo Console (RS-232) Il presente prodotto può essere configurato con un qualunque browser, come Internet Explorer 6 o Netscape Navigator 6 o versioni superiori. DFL-700 NETDEFEND Network Security Firewall Prima di cominciare

Dettagli

ESEMPI INTEGRAZIONE PRODOTTI

ESEMPI INTEGRAZIONE PRODOTTI System Manual ESEMPI INTEGRAZIONE PRODOTTI Teleassistenza Twido-Suite & Twido con TSXETG1000 SIXNET SM_0014 Si realizza una connessione remota con l ausilio dell Internet Protocol Suite, di cui in particolare

Dettagli

DI-604 Express EtherNetwork Broadband Router

DI-604 Express EtherNetwork Broadband Router Il presente prodotto può essere configurato con un qualunque browser, per esempio, Internet Explorer 5x, Netscape Navigator 4x.` DI-604 Express EtherNetwork Broadband Router Prima di cominciare 1. Se si

Dettagli