MD9900. Dual Function Smoke Detector D24728 Rev. D. Microdata Due Martec Group



Documenti analoghi
MD9901. Dual Function Plus Smoke & Heat Detector D24731 Rev. C. Microdata Due Martec Group

MD9901-EX Intrinsically Safe Multi-Criteria Fire Detector

MD2208. Multi I/O Control Module D32305 Rev. B. Microdata Due Martec Group

MD9901. Dual Function Plus Smoke & Heat Detector. Microdata Due Martec Group

MD2203 MD2205. Check Point & Fire Patrol. Microdata Due Martec Group

LCU. Loop Control Unit. Microdata Due. Martec Group

MD9800-LC. Fire Alarm Central Unit. Microdata Due Martec Group

USER MANUAL 2AMIN521VS

Manuale per il collegamento e l uso Installation and operation manual

TLR05S-350. Extender in corrente costante, 3 x 350mA per TLR04M_

Caratteristiche tecniche Technical data Dimensioni cassetta

MAGNET LINK SURFACE MOUNTED

MD9902. Addressable Flame Detector. Microdata Due D25795 Rev. G Page 1 / 14

INTECNO TRANSTECNO. MICRO Encoder ME22 ME22 MICRO Encoder. member of. group

MOSAIC MOR4/MOR4S8 RELAY OUTPUT EXPANSION UNIT

TRF. Trasmettitore di peso wireless Weight transmitter wireless

MD2010-CU. Fire Alarm Central Unit. Microdata Due Martec Group

MODALITA DI IMPIEGO PD

User Manual. Rev Date: 31/05/2018

Codice: LEDALITF INDUTTIVO INDUCTIVE INDUTTIVO INDUCTIVE. Trasformatore Lamellare. Trasformatore Toroidale. Toroidal Transformer

Umidità relativa - Relative humidity : 98% RH senza condensazione - RH without condensing

SISTEMA CAMPALE RILEVAZIONE INCENDIO

controllo inclinazione veicolo

MANUALE OPERATIVO / INSTRUCTION MANUAL IM200-IU v1.3 CT / CTD CT / CTD. Toroidal current transformers. Trasformatori di corrente toroidali. pag.

SISTEMA DI ILLUMINAZIONE PER VERRICELLI WINDLASS LIGHTING SYSTEM

Pulsante manuale. Sinteso / Cerberus PRO FDM231-RP, FDM231-RP(F) Pulsante manuale per il bus del rivelatore FDnet/C-NET indirizzabile automaticamente

Indicatori esterni di allarme

controlli di livello capacitivi capacitive levels controls

LC1AZ - LC1DZ. Elettrovalvole dirette controllo direzione Solenoid operated directional valves

ECHO ECHO PLUS LCA MCA UGRV UGRS E E UGR/HS MCE MPE MFE MXE MTE MCC MPI PCDS PANNELLO DI COMANDO A DISTANZA SEMPLIFICATO

TLR02. Dimmer per Led in tensione costante a 4 canali

WIN 3 / ANA SAEL S.R.L. Load cells digital amplifier...english [Pag ] Amplificatore digitale per celle di carico...italiano [Pag.

Fire detection systems

sensori per cilindri magnetic sensors for cylinders

Product QUADRI ELETTRONICI ELECTRONIC CONTROL PANEL - ECL 1 / ECL 2-

13 tipi di suono selezionabili, 2 livelli di allarme programmabili Livello sonoro regolabile fino a 91 dba

CONTROL FAN SYSTEM VENTILATORI BLOWERS. Sistemi di controllo Control Systems SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM

SOLID STATE RELAY MODULES - 1 STAGE 3A WITH FUSE PROTECTION SOLID STATE RELAY MODULES - 4 STAGE 3A WITH FUSE PROTECTION

MB-PULSE 4 Product Manual MB-PULSE 4 Manuale Prodotto

Velvet Lab. Velvet. MADE IN ITALY

ELCART. Manuale di istruzioni/scheda tecnica SPECIFICATION. Flexible LED strips DATE Standard Flexstrip RGB Colour IP20

LAMPEGGIANTI A LED HIGHLIGHT LED BEACONS

ACTUATOR FOR MIXING VALVES

MANUALE D USO 2AMDI515TPS

FARI DA LAVORO A LED ELLIPSE LED WORKLAMPS. TEST STANDARDS FOR ELECTRONIC COMPONENTS EMC: CISPR 25 class lumen

TFT LCD -5 /COL Monitor a colori LCD TFT 5 senza fili 2.4 GHz 2.4 GHz Wireless CCD 5" TFT color LCD monitor

sensori per cilindri magnetic sensors for cylinders Schema di collegamento: 2 fili Wiring diagram: 2 wires RS2-A RS1-A RS3-A RS4-A RS5-C Modello Model

SENSORI CAPACITIVI CAPACITIVE SENSORS

group HIGH CURRENT MULTIPLEX NODE

Basette per il montaggio di elettrovalvole Mounting plate for solenoid valve

Materiali impiegati. 1 OPERATORE: Ottone, Acciaio INOX 2 CORPO OPERATORE: POM. 3 CORPO VALVOLA: Alluminio. 6 MOLLA: Acciaio INOX

OPTIKA. OPTIKA Sistema per effetti a parete in singola o doppia emissione per lampada alogena lineare

FLYBACK FLYBACK114 FLYBACK76 FLYBACK50

TACTÒ TASTIERA EFFETTO HALL KEY PAD HALL EFFECT

Termostato / Thermostat

CONNETTORI CON CAVO COSTAMPATO

WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]

SUNWAY STRING BOX. Parallel string box. Cassetta di parallelo stringhe

DIMMER LED CON TELECOMANDO TOUCH 2.4G RF (4 ZONE) / LED DIMMER WITH 2.4G RF TOUCH REMOTE (4 ZONE)

PUMP CONTROLLER PUMP ACTIVE CONTROLLER

ADUNI AVVIATORE DIRETTO PER GRUPPI ANTINCENDIO (UNI EN-12845) UNI EN DIRECT STARTER FOR FIRE-FIGHTING GROUPS

Transcript:

MD9900 Dual Function Smoke Detector D24728 Rev. D Descrizione Si tratta di un rilevatore automatico di tipo indirizzabile in grado di fornire un allarme incendio per presenza fumo, e nello stesso tempo di rilevare la temperatura all interno del locale dove è installato. Trasmette alla Centrale MD9800 i valori analogici relativi alla temperatura ed alla quantità di fumo misurata. Il sistema di rilevamento del fumo è di tipo ottico, basato sull effetto Tyndall: impiega un emettitore, con funzionamento impulsivo, ed un ricevitore operanti nel vicino infrarosso, posti all interno della camera ottica protetta dalla luce esterna ma in contatto con l atmosfera. L ingresso del fumo all interno della camera provoca un aumento dell energia captata dal ricevitore, il cui segnale di misura viene gestito da un circuito di condizionamento ed inviato al microprocessore per la sua elaborazione. Un sensore dedicato fornisce un valore analogico di tensione, proporzionale alla temperatura misurata, che viene trasferito al microprocessore per la sua elaborazione. Il software del rivelatore permette una valutazione assolutamente selettiva sulla misura relativa alla presenza di fumo all interno della camera ottica, attraverso sofisticati algoritmi, permette di escludere tutte le misure influenzate da disturbi esterni. La valutazione nel tempo di queste ultime provoca l invio alla Centrale MD9800 della condizione di Sensore disturbato. La Centrale MD9800, correlando nel tempo i dati analogici della misura all interno della camera ottica in assenza di fumo quando questa supera una determinata soglia e permane sopra questa, attiva la segnalazione di avaria per Sensore sporco. Il rivelatore controlla continuativamente la propria componente ottica, ed è in grado di fornire la segnalazione di avaria in caso di guasto o di degrado. Description MD9900 is an automatic addressable detector able to provide fire alarm in case of smoke presence and to survey the temperature inside the room where it is installed. It sends to the MD9800 Central Unit the analog values of temperature and smoke that it measures. The smoke detection unit is of optical type, based on Tindall effect. It includes a pulse type emitter and a receptor working in infrared band, located inside the optical chamber, protected from external light but in contact with atmosphere. The ingress of smoke inside the chamber causes an increase of the energy received by the receptor, energy which is measured and handled by a conditioning circuit and sent to the sensor microprocessor. Another dedicated sensor provides a voltage analog signal proportional to measured temperature, signal which is sent to the microprocessor for its processing. The detector software allows a very selective assessment of the smoke measurement inside the optical chamber, thanks to advanced algorithms. This allows to exclude any wrong measurement due to external perturbation. Those perturbations are tracked by the microprocessor which can then transmit a "Noise Detector" anomaly to the MD9800 Central Unit. The MD9800 Central Unit monitors the evolution in the time of the analog value in the detector optical chamber without smoke. If this value go over a preset threshold for a long time a Polluted Detector fault signalization is displayed. The detector continuously monitors the optical component and is able to provide a fault signalization in case of optical sensor failure or degradation. Microdata Due Martec Group Via Greti del Vara, 9 19020 Follo (SP) Italy Tel. +39/0187/599101 Fax. +39/0187/558983 www.microdatasrl.it E-mail: info@microdatasrl.it

Descrizione Il colloquio sul loop con la Centrale MD9800, avviene attraverso le schede di controllo LCU che forniscono al rivelatore l alimentazione a 24Vcc, sulla quale è modulata una trasmissione seriale con protocollo MD2. La programmazione dell indirizzo avviene in modo software, attraverso la Centrale MD9800. In caso di avaria della Centrale (Mancanza di interrogazione dei rivelatori sul Loop), si attiva lo stato di Funzionamento degradato del rivelatore, che continua a funzionare, e in caso di allarme, invia un segnale di tipo digitale alla Centrale. Sul corpo del rivelatore è presente una segnalazione ottica (led rosso) lampeggiante, come indicazione di allarme. Description The communication through the loop with MD9800 Central Unit is performed by LCU control cards which provide to the detectors the 24Vdc power supply on which is modulated a serial transmission signal using MD2 protocol. The detector address is programmed by software from the MD9800 Central Unit. In case of MD9800 Central Unit fault (loss of communication with detectors through loop card), the Degraded mode is activated: In case of fire alarm, a digital signal is sent to the MD9800 Central Unit. An optical signalization (red Led) on the detector housing flashes in case of alarm detected. Omologazioni Type Approval According to UNI EN54-7 Ed. 2000 and Lloyds Register of Shipping Test Specification Nr. 1 2002. Test performed by BRE Ltd., England. RINA Lloyd s Register DNV Italian Transport Ministry Installazione Per l installazione ed il collegamento sul loop il rivelatore è dotato di una base standard o stagna IP65, alla quale si collega meccanicamente tramite innesto rapido a baionetta, ed elettricamente mediante un connettore volante. Installation To ease wiring the detector is installed on a base, provided in standard or IP65 proof version. The detector is connected to the base through a fast bayonet clutching and a flying connector. Microdata Due D24728 Rev. D Page 2 / 5

Codici di ordinazione Modello Model MD9900 25626 MD9900-PR 26639 MD9900-BC MD9900-BCI MD9900-BS MD9900-BSI Codice Part Number 26397-BS 26397-BSI 26398-BS 26398-BSI MD9900-BBZ 26640 MD9900-BT 26165 MD9900-I 27179 MD9900-BO 26641 Order Code Descrizione Description Rivelatore di Fumo Dual-Function Dual-Function Smoke Detector Protezione per rivelatore Detector Protection Base IP32 per installazione a controsoffitto Base IP32 for false-ceiling installation Base IP32 per installazione a controsoffitto con isolatore di cortocircuito Base IP32 for false-ceiling installation with short circuit isolator Base stagna IP65 Proof Base IP65 Base stagna IP65 con isolatore di cortocircuito Proof Base IP65 with short circuit isolator Base IP32 con buzzer di segnalazione Base IP32 with buzzer Piastra porta-indirizzo (Kit 10 pezzi) Label plate (Kit 10 pcs) Targhette indirizzo (Kit 24 pezzi) Address Label (Kit 24 pcs) Segnalatore ottico esterno External optical signalization Documenti di Riferimento Related Documents Technical Specification ST-21405 Caratteristiche tecniche Grado di protezione...ip32/65 (secondo base) Peso (solo rivelatore)...150 gr Peso con base IP32...200 gr Peso con base IP65...280 gr Materiale... Policarbonato Flame Retarded Cl. UL94V0 Colore...Bianco RAL9010 Temperatura di funzionamento...-25 C +75 C Tensione di alimentazione...24vcc (modulato) Assorbimento...350 µa Technical Features Protection Index... IP32/65 (depending of base) Weight (only detector)...150 gr Weight (with IP32 base)...200 gr Weight (with IP65 base)...280 gr Material...Polycarbonate Flame Retarded Cl. UL94V0 Color...White RAL9010 Operating Temperature...-25 C +75 C Power Supply...24Vdc (moduled) Max Current...350 µa Microdata Due D24728 Rev. D Page 3 / 5

Ingombri e dima di fissaggio Outline & Cut-Out BASE IP32 BASE IP65 Microdata Due D24728 Rev. D Page 4 / 5

Connessioni Connections BASE IP65 BASE IP32 Microdata Due D24728 Rev. D Page 5 / 5