REMOTE PANEL PANNELLO REMOTO



Documenti analoghi
EN IT. Computer Manual. Manuale computer. Console

CONFIGURATION MANUAL

Guida utente User Manual made in Italy Rev0

Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software

Manuale Utente Rev. 0.3 del 26/11/2004

Attuatore a relè Manuale di istruzioni

Regolatore di carica per HYDRO-CHARGER e pannelli solari. Istruzioni d uso. Si prega di leggere attentamente prima dell uso

Portale Materiali Grafiche Tamburini. Grafiche Tamburini Materials Portal


quick guide guida rapida J.touch hydromassage bath remote control telecomando per vasche idromassaggio

MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

SOMMARIO GENERALITÀ 3 AGGIORNAMENTO FIRMWARE 4 PROGRAMMAZIONE DEL MICROPROCESSORE 7 AGGIORNAMENTO MULTICOM 302 / AGGIORNAMENTO MULTI I/O 5

Guida all installazione del prodotto 4600 in configurazione plip

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

User Guide Guglielmo SmartClient

MANUALE DI ISTRUZIONI

DICHIARAZIONE DI RESPONSABILITÀ

ITALIANO. Manuale d uso

Attuatore a relè Manuale di istruzioni

REGISTRATION GUIDE TO RESHELL SOFTWARE

GSM Dialer. Ottimo dispositivo da collegare ad antifurti PSTN ma anche ad altre apparecchiature

Scheda CPU Logika OKIR 510B Irinox cod

LEGEND UPDATE GUIDE INSTALLING LEGEND UPDATE. viscount. Legend Update Guide

Guida alla configurazione Configuration Guide

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

Kit trasmissione. data transmission. Ref

INSTALLARE PALLADIO USB DATA CABLE IN WINDOWS XP/ME/2000/98

SRT064 BTH SRT051 BTH SRT052 BTH

(Versione Gas 4) Manuale d istruzione

GSM Dialer. Dispositivo da collegare ad antifurti PSTN ma anche ad altre apparecchiature

PANNELLO REMOTO PER BARRIERE 48BFC000 E 48BFC001

CUSTOMER SERVICE GPS/ RADIOTRACKING DOG COLLAR. T. (+34) F. (+34)

INTERFACCIA SERIALE RS232PC

indice Introduzione 1 Specifiche 1 Contenuto della confezione 2 Utilizzo della sigaretta 3

TACTÒ TASTIERA EFFETTO HALL KEY PAD HALL EFFECT

TASTIERA DI COMANDO E CONTROLLO PER INVERTERS EL.-5000

Wireless ADSL VPN Firewall Router

CCTV DIVISION. Guida Alla Lettura del Numero Seriale, Codice Prodotto, Versione Firmware, Versione Software, Codice Libretto

UPS ON LINE A DOPPIA CONVERSIONE TOWER DA 1 A 3 KVA EBK VISION

Nautilus Installazione Aggiornato a versione

Salvataggio e ripristino configurazione utente dei ricevitori SAT+ S 3.1 e X 9.1.

Guida rapida di installazione

COMBINATORE TELEFONICOMOD. KIM10GSM Istruzioni Base

TELEMETRIA GSM PER GSE

EXIWAY POWER Manuale integrativo di installazione ed uso del soccorritore Exiway Power per applicazione in impianti di illuminazione d emergenza

group STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER CAN J1939 ISOBUS - ISO11783 VT3 SOFTWARE DEVELOPMENT TOOLS IEC 61131

Aggiornamento dispositivo di firma digitale

Compatibilità del Portale Piaggio con Internet Explorer 10 e 11. Internet Explorer 10

INTERFACCE SNMP E SOFTWARE PER UPS MONOFASE

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s

SISTEMA DI ILLUMINAZIONE PER VERRICELLI WINDLASS LIGHTING SYSTEM

Tester per Resistenza di Terra a 4 fili Modello GRT300. Manuale d'istruzioni

Manuale d uso Jump Starter

Temperatura di Lavoro / Working Temperature. Distanza di controllo/ Distance control

Da RS232/RS485 a LAN 10/100BaseT Ethernet. (Foto) Manuale d installazione e d uso V1.00

EC98 contamonete professionale. Manuale di utilizzo

Centralina Compatta. Manuale d istruzioni. 04/2015 Dati tecnici soggetti a modifi che. info@psg-online.de

RIPETITORE DI SEGNALE WIRELESS PER SISTEMA VIA RADIO ART. 45RPT000

1. PC Laptop (S.O: Windows 7 preferibile) 2. Adattatore USB- RS232 (Non ci sono richieste specifiche sull adattatore da Utilizzare)

SINUS PENTA MANUALE SPARE ES821

Da RS232/RS485 a LAN 10/100BaseT Ethernet

MANUTENZIONE I PRIMO LIVELLO (MONOFASE)

Posta elettronica per gli studenti for the students

Manuale di programmazione BerMar_Drive_Software

Keys-To-Go. Ultra-portable keyboard for Android and Windows. Setup Guide

Serie IST1. Line Interactive VA. Manuale D'uso CONSERVARE QUESTO MANUALE

Quick start manual Manuale rapido. Version 3.0

Presentazione. Installazione, connessione e uso di Intelligent NAS 2014/7

SP-1101W Quick Installation Guide

Gruppo di continuità UPS. Kin Star 850 MANUALE D USO

1 ABILITAZIONE PORTA USB

DTDMXRGB LED DRIVERS. Descrizione del prodotto

MANUALE D USO MA-PMX-U-SFW

Gruppi di continuità UPS Line Interactive. PC Star EA

Foglio Integrativo del manuale Serie Trivalente

-Fig.1-

MANUTENZIONE INVERTER LEONARDO

Manuale utente Borri Power Guardian

IL SISTEMA PRATICO E VELOCE PER ANALISI DEL MOVIMENTO

OTDR MT9083 Serie ACCESS Master

Manuale di istruzioni del Sistema di Gestione delle Batterie (BMS) del kit plug-in Enginer. BMS 16D Versione 3 e 4 MANUALE PER L UTILIZZATORE

HVDP. High Voltage Dynamic Power supply/source. Potenza: in uscita 1, 2.5 e 5kW in DC + sinusoidale.

RELAY interface for HF, HF Line, HF Top Line, Ally and Megaline series

PROG TOOL MANUALE D USO

ACINT01. INTERFACCIA LAN PER CENTRALI ANTINCENDIO AC501 e AC502 ACINT01 REV.00-30/04/15 1

T2210HD/T2210HDA Monitor LCD Wide Screen 21,5" Manuale dell utente

MANUALE ISTALLAZIONE MYBOAT

CEDMEGA Rev 1.2 CONNECTION TUTORIAL

Istruzioni per configurazione SmartComm (in passività) Ultimo Aggiornamento: 22 settembre 2011

24Vdc in (rosso e nero) K-P2C o K-P2C

INFORMAZIONI PER LA REGOLAZIONE DELLE SOGLIE DI FREQUENZA NEGLI INVERTER POWER-ONE IN ACCORDO ALLA DELIBERA DELL AEEG 243/2013/R/EEL (6 Giugno, 2013)

Manuale di istruzioni del regolatore di carica per modulo fotovoltaico. Serie EPRC10-EC/PWM ITA

ConferenceCam Connect. QuickStart Guide

Hobbes. TESTER PER RETI LAN LANtest Pro Modello: /LB. Manuale d'uso

Registratore Dati Umidità e Temperatura

IF2E001 Interfaccia Ethernet-RS485

POWERGATE-S USER GUIDE

Software di monitoraggio UPS. Manuale utente Borri Power Guardian

sdforexcontest2009 Tool

Transcript:

REMOTE PANEL PANNELLO REMOTO User s manual Manuale utente

Index/Indice User s Manual - English... 1 Safety Warnings... 1 1 SYSTEM DRIPTION... 2 1.1 Introduction... 2 2 INSTALLATION AND COMMISIONING... 2 2.1 Preliminary Warnings... 2 2.2 Configurator... 2 3 DISPLAY AND BUTTONS... 4 3.1 LEDs... 4 3.2 Buttons... 5 3.3 LCD Display... 6 3.4 Buzzer... 8 4 USAGE... 9 4.1 Buzzer Switch ON/OFF... 9 4.2 Battery Test ON/OFF... 9 4.3 Cancel Battery Test... 10 4.4 Shutdown UPS... 10 4.5 Control UPS serial number and production date... 11 4.6 Remote Comunication Panel Status Monitoring... 11 5 PC COMMUNICATION... 15 6 TECHNICAL SPECIFICATIONS... 15 Manuale Utente Italiano... 17 Avvisi di Sicurezza... 17 1 DRIZIONE DEL SISTEMA... 18 1.1 Introduzione... 18 2 INSTALLAZIONE E UTILIZZO... 18 2.1 Avvertenze... 18 2.2 Configurazione... 18 3 DISPLAY E TASTI... 20 3.1 LED... 20 3.2 Tasti... 21 3.3 Display LCD... 22 3.4 Allarme Acustico... 24 4 D USO... 25 4.1 Allarme Acustico ON/OFF... 25 4.2 Test Batteria ON/OFF... 25 4.3 Annullare Test Batteria... 26 4.4 Shutdown dell UPS... 26 4.5 Controllo Numero Seriale e Data di Produzione dell UPS... 27 4.6 Stato del Pannello Remoto... 27 5 COMMUNICAZIONE CON PC... 31 6 SPECIFICHE TECNICHE... 31

ENGLISH User s Manual - English Safety Warnings Read this manual carefully and completely before installing and using the product. The product must be used only by properly trained personnel. To ensure correct and safe operations, it is necessary that operators and maintenance personnel observe the general safety Standards as well as the specific instructions included in this manual. Risk of electric shock: do not remove the cover. The product contains internal parts which are at a high Voltage and are potentially dangerous, capable of causing injury or death by electric shock. There are no internal parts in the product which are user serviceable. Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. The electric installation has to be done by qualified personnel. Follow all the Safety Standards (CEI Standards in Italy or IEEE elsewhere). Do not insert objects or pour liquids in the ventilation holes. Install the product indoors, in a protected, clean and moisture-free environment. Do not expose to the direct sun light. Do not keep liquids, flammable gases or corrosive substances near the product. Remote Panel 1 User s manual

ENGLISH 1 SYSTEM DRIPTION 1.1 Introduction TECNOWARE Remote Control and Monitoring Panel (RCMP) provides the user to monitor all the information displayed on the front panel of the UPS, and control your UPS. RMCP enables you to save the history log of your UPS. 2 INSTALLATION AND COMMISIONING 2.1 Preliminary Warnings Check if the UPS has been subjected to any damage before unpacking it. If you notice any damage then contact the transport company. Check if all the accessories have been supplied with the device. A delivered pack includes: RCMP User s Manual RCMP - UPS Data Cable RCMP - Adaptor Cable Adaptor UPS Cable 2.2 Configurator 2.2.1 Rear View 9 Pin Female PC Connection 9 Pin Female UPS Connection 9 Pin Male Adaptor Connection Switch to chose communication distance User s manual 2 Remote Panel

2.2.2 Installation ENGLISH Please connect your RCMP to the mains with the power cable supplied with you RCMP. Turn the switch to ON position. Your RCMP is ready to start. Even though you don t connect your RCMP to the mains, it may approximately 24 hours thanks to internal battery. Whenever you make the mains condition, the battery inside will automatically start to charge. 2.2.3 Communication Interface Connection If you use RCMP at a distance from 1.5m to 25m (serial cable 25m optional) from the UPS, do the following instructions: UPS Setting: from the menu select COMAND press Enter button and with button check if is selected COMM=RS232. If not press Enter button to change. Check if the two dip switch on the UPS interface board are on RS232 position (both in down position). Connect the communication cable to RS232 port. RCMP Setting: 1 Position the two dip switch in Converter position (both in up position). 2 Connect the communication cable to UPS RS232 port. 3 Connect the power cable to RCMP. 4 Switch on RCMP. If you use RCMP at a distance from 25m to 100m from the UPS, do the following instructions: Use the two DB9 connectors supplied and wire the connection between a CAT.5 shielded cable. UPS EVO DSP TT-TM RS422 port Pannello Remoto RS488 port Male DB9 Connector 2 9 1 5 6 4 4 9 1 5 6 2 Female DB9 Connector UPS Setting: from the menu select COMAND press Enter button and with button select RS232 and press enter to change in RS485. Check if the two dip switch on the UPS interface board are on RS232 position (both in down position). Connect the communication cable to RS422 port. RCMP Setting: 1 Position the two dip switch in UPS position (both in down position). 2 Connect the communication cable to Converter RS488 port. 3 Connect the power cable to RCMP. 4 Switch on RCMP. Remote Panel 3 User s manual

ENGLISH 3 DISPLAY AND BUTTONS In the below picture, the front panel of the remote panel which provides all the information needed concerning about operation of the UPS with the LCD, LEDs and buttons to the user, is displayed. Description and functions of the LCD panel, buttons and other indicators is described in the ext section. 3.1 LEDs Six indications are found on the panel. These indications and their functions are explained below: LINE (Mains) When the mains is within normal limits then the green light is on. When the mains is out of normal limits or if there is a blackout then the green light continues to blink. BATTERY (Battery Mode) This red light is not on, when the UPS is operating from mains, but when it is on Battery mode, MN ABNML is message is displayed on the LCD and an audible warning alarm is heard. When the battery capacity is less than 30 %, the light continues to blink. BY-PASS (By-pass Mode) This yellow light is on continuously when the load is directly connected to the mains or by-pass and BYPACT is message is displayed on the LCD with an audible alarm. OVERLOAD (Overload > % 100) This indication is continuously on during overload conditions. When the UPS is on overload the green light blinks continuously with an audible alarm and OVERLOAD is displayed on the LCD. INVERTER This green light indicates that the load is being supplied through the inverter. User s manual 4 Remote Panel

ENGLISH FAULT If the semi-conductor junction temperature exceeds the upper limit. If the cooling temperature, exceeds the upper limit. If the Battery temperature exceeds the upper limit. If there is a Fan malfunction. If the Battery fuse goes off. If the battery test isn t successful. If there is an inverter failure. If there is an Output error. Or if there is any fault. This light blinks and gives an audible alarm. 3.2 Buttons There are 4 buttons on the RCMP. These buttons have the following functions: Button This button shows all the stored digital information by scanning it and provides to adjust some values to negative. The digital information is in the following order: LD1, LD2,LD3 : Output power - [ Output current/nominal current ] (%) Vsc1,Vsc2,Vsc3 : r,s,t Phases Output Voltages (V) Isc1,Isc2,Isc3 : r,s,t Phases Output Currents (A) Fout : Output Frequency (Hz) Vby1,Vby2,Vby3 : r,s,t Phases Bypass Voltages (V) Vin1,Vin2,Vin3 : r,s,t Phases Input Voltages (V) Iin1,Iin2,Iin3 : r,s,t Phases Input Currents (A) Fin : Input Frequency (Hz) Vbtp : Total Battery Voltage (positive) (V) Vbtn : Total Battery Voltage (negative) (V) Button This button has functions the same with button, but to the positive direction. (Escape) Button This button provides you to get out from the menu, and pass to the other menu table. (Enter) Button This button provides you to enter main menu on the screen, confirmation of the changes. Remote Panel 5 User s manual

ENGLISH 3.3 LCD Display The LCD panel displays the UPS mode, status, active alarms, and messages related to the errors or failures numerically. As shown in the diagram below, the messages that give information related to the UPS can be seen in specific areas of the LCD panel. In this section these messages and their meanings are explained. User s manual 6 Remote Panel

ENGLISH Abbreviations related to the UPS s operation status appear in the space OPERATION STATUS as seen above. Following is a list of the abbreviations used. BTSTACT S.D.ACT BZ. ACT BYPSWON INV OFF RCT ACT RCT DIS INV DIS BYPMDIS GREENMD GENSET OFFSWON DCBUSCH NO COMM 1 : Battery Test Active : Shut Down Active : Buzzer Active : Bypass Switch On : Inverter Off : Rectifier Active : Rectifier not Active : Inverter not Active : Bypass Mode not Active : ECO Mode (Bypass Priority Mode) : GENSET Active : UPSOFF Switch On : DC Capacitors Charging : No Communication between RCMP and UPS The abbreviations for relevant alarms seen above in the ALARM portion of the LCD are as follows 2: OK MN ABNL BATT LOW UPSFAULT BYP V FA BYP V HI BYP V LO BYP SYNC BYP SEQ: INV TEMP OUT OVER BYP ACT. INV BLO. SBUS V F INP V HI INP V LO INP SYNC INP SEQ. RCT TEMP RCT OVER DCBUSVHI DCBUSVLO RCT BLO. BT DISCH DCBUSVFA TEMP HI BT TST F OVERLOAD WITH UPS 1 : No Alarm : Abnormal Mains : Low Battery Voltage : Fault (see. FAULT LED) : Bypass Voltage out of limits. : High Bypass Voltage : Low Bypass Voltage : Bypass Synchronization : Bypass Sequence : Inverter Overheated : Output Overloaded : Bypass Active : Inverter Blocked : Output Voltage Out-of-Limits : High Input Voltage : Low Input Voltage : Input Synchronization : Input Sequence : Rectifier Overheated : Rectifier Overloaded : High DC Bus Voltage : Low DC Bus Voltage : Rectifier Blocked : Battery Discharging : DC Bus Voltage Out-of-Limits : High Ambient Temperature : Battery Test Failure : Overload : No Communication between RCMP and UPS Note 1: These messages are meaningful only when they are seen at the same time. Note 2: In the event of more than one alarm occurring at the same time, the code for the alarm that occupies the last position in the row will appear. Remote Panel 7 User s manual

ENGLISH In the PARAMETERS section the abbreviations for the parameters that are looked for, can be seen by using the MODE key. These can be listed as follows: LD1, LD2, LD3 : Output power - [Output current/nominal current] (%) Vsc1,Vsc2,Vsc3 : r,s,t Phases Output Voltages (V) Isc1,Isc2,Isc3 : r,s,t Phases Output Currents (A) Fout : Output Frequency (Hz) Vby1,Vby2,Vby3 : r,s,t Phases Bypass Voltages (V) Vin1,Vin2,Vin3 : r,s,t Phases Input Voltages (V) Iin1,Iin2,Iin3 : r,s,t Phases Input Currents (A) Fin : Input Frequency (Hz) Vbtp : Total Battery Voltage (positive) (V) Vbtn : Total Battery Voltage (negative) (V) In the VALUE section the values for the parameter chosen can be seen using the or buttons. 3.4 Buzzer When the FAULT sign switches on and off. When the UPS is in the battery mode. When the system experiences an overload (overload, out over). When the RCMP battery voltage is low. The buzzer sounds an audible alarm every 2 seconds. User s manual 8 Remote Panel

ENGLISH 4 USAGE Push the button to enter the main menu. 4.1 Buzzer Switch ON/OFF ********* REMOTE CONTROL Main Screen Remote Control Buzzer ON / OFF TOGGLE BUZZER? NO / YES YES Buzzer on / off 4.2 Battery Test ON/OFF ********* REMOTE CONTROL x 1 Main Screen Batt. Test ON / OFF Str/Stp? NO / YES YES Battery Test Remote Panel 9 User s manual

ENGLISH 4.3 Cancel Battery Test ********* REMOTE CONTROL x 2 Main Screen Cancel Batt. Test Stop Batt Test? NO / YES YES Cancel Batt. Test 4.4 Shutdown UPS ********* REMOTE CONTROL x 2 Main Screen Shut Down UPS Turn Off UPS? NO / YES YES NO Are You Sure? NO / YES YES Shutdown UPS User s manual 10 Remote Panel

ENGLISH 4.5 Control UPS serial number and production date REMOTE CONTROL UPS IDITY Model: PD XXXkVA Version: 1.0 4.6 Remote Comunication Panel Status Monitoring In this menu, some parameters like hour/ date, communication mode, software version, monitor internal battery voltage, clear history log and LCD contrast may be adjusted. 4.6.1 Hour/Date Adjustment x 2 UPS IDITY RCMP STATUS RCMP Time / Date hh/mm/ss dd / mm CHANGE TIME? NO / YES In this sub-menu, hour and date of RCMP Module may be adjusted. The values may be adjusted in up or down directions with, buttons. To enter the next parameter (ex. from hour to minute adjusting), push button once and make adjust with, buttons. After month parameter adjusting, push button and exit from hour/date menu. For canceling, push button. Remote Panel 11 User s manual

ENGLISH 4.6.2 Monitoring Communication Mode and Software Version x 2 UPS IDITY RCMP STATUS Comm. Via RS XXX SW Version X.XX 4.6.3 Monitoring Internal Battery Status x 2 UPS IDITY RCMP STATUS x 2 Inter. Batt. XXX V %XXX RCMP has internal battery. In case of electricity cuts, internal battery provides 4 hours back up time to RCMP. If the battery voltage is lower than 12V, Ibatt Low warning will be displayed on the main screen. If the voltage decreases lower 10V, RCMP will shutdown automatically. If the mains exist, batteries are charged. User s manual 12 Remote Panel

ENGLISH 4.6.4 Clear History Log x 2 UPS IDITY RCMP STATUS x 3 ERASE EV FILE ARE YOU SURE? NO / YES All the history log will be cleared. It takes about 30 seconds. 4.6.5 Contrast Adjustment x 2 UPS IDITY RCMP STATUS CONTRAST x 4 Change Contrast XXX In this menu, contrast of RCMP monitor may be adjusted. Values may be adjusted in up or down directions with the, buttons. Make confirmation by push button. For cancelling, push button. Remote Panel 13 User s manual

ENGLISH 4.6.6 Monitoring History Log x 3 RCMP STATUS EV FILE XXXXXXXXXXXXX KK- SS/DD GG/AA ALARM STRING XXXX XXXX XXXX In this section, there are other events being displayed. To view them press the button and then press " ". When you enter Event File menu, it is shown the latest history. The parameters are as follows: XXXXXX: Description of the saved history. KK: Event save turn. SS: Event happening time. DD: Event happening minutes. GG: Event happening day. AA: Event happening month. You may display previous or latest history events using, buttons. During the event display, if you push button, it will show you some parameters at the event time. These parameters are shown at attachment and important for your technical service. User s manual 14 Remote Panel

ENGLISH 4.6.7 Monitoring Momentary Alarms x 4 EV FILE ALARMS ALARM STRING XXXX XXXX XXXX ALARM STRING-ANN TTTTTTTTTTTTTTT Momentary alarms on UPS may be seen by this menu. In main menu, under ALARM STRING part, 3 lines with 4 characters are seen. In this menu, if you push button, alarms related to this line may be seen. To enter other alarms, or buttons may be used. 5 PC COMMUNICATION Please connect the data cable given with the software to 9 pin female PC socket of your RCMP and the other side to your PC. 6 TECHNICAL SPECIFICATIONS Mains input voltage range: 100-260 Vac 50/60 Hz automatic Internal battery back up time: about 24 hours Working temperature: -5/+50 C Remote Panel 15 User s manual

ENGLISH User s manual 16 Remote Panel

ITALIANO Manuale Utente Italiano Avvisi di Sicurezza Leggere attentamente e completamente questo manuale prima di installare ed utilizzare il prodotto. Il prodotto deve essere utilizzato solo da personale opportunamente istruito. Per l uso corretto e in condizioni di sicurezza è necessario che gli operatori ed il personale di manutenzione si attengano alle norme generali di sicurezza, in aggiunta alle norme specifiche contenute in questo manuale. Rischio di shock elettrico: non rimuovere il coperchio. Il prodotto presenta parti interne sotto tensione che sono potenzialmente pericolose e possono provocare lesioni o morte per shock elettrico. Il prodotto non ha parti interne soggette a manutenzione da parte dell utente. Interventi tecnici di qualsiasi tipo devono essere compiuti solo da personale tecnico specializzato ed autorizzato da TECNOWARE. In caso contrario TECNOWARE declina ogni sua responsabilità. L'installazione elettrica, nonostante la sua semplicità, deve essere eseguita esclusivamente da elettricisti qualificati. Seguire scrupolosamente tutte le norme locali e nazionali (in ITALIA le norme CEI. Non inserire oggetti o versare liquidi nei fori di ventilazione. Installare il prodotto in ambiente chiuso, pulito e privo di umidità. Non esporre il prodotto alla luce diretta del sole. Non avvicinare liquidi, gas infiammabili o sostante corrosive. Pannello Remoto 17 Manuale Utente

ITALIANO 1 DRIZIONE DEL SISTEMA 1.1 Introduzione Il pannello remoto TECNOWARE per UPS EVO DSP TT-TM consente di monitorare tutte le informazioni presenti sul display sul pannello frontale dell UPS, e di controllare quest ultimo. Consente inoltre di salvare lo storico degli eventi dell UPS. 2 INSTALLAZIONE E UTILIZZO 2.1 Avvertenze Verificare se il prodotto ha subito danni prima di disimballarlo. Se è presente un qualsiasi tipo di danno contattare il corriere. Verificare se tutti gli accessori sono presenti a corredo. La dotazione completa comprende: Pannello Remoto Manuale Utente Cavo dati Pannello Remoto-UPS Adattatore - Cavo Pannello Remoto Adattatore Cavo UPS 2.2 Configurazione 2.2.1 Pannello Posteriore Connettore femmina PC 9 Pin Connettore femmina UPS p Pin Adattatore machio 9 pin Switch per la scelta della distanza della comunicazione Manuale Utente 18 Pannello Remoto

2.2.2 Installazione ITALIANO Collegare il pannello remoto all alimentazione tramite il cavo a corredo. Porre l interruttore sulla posizione ON. Il pannello remote è pronto per l utilizzo. Anche nel caso in cui non si colleghi il pannello remote all alimentazione, è possibile utilizzarlo comunque grazie alla batteria interna che garantisce un autonomia di circa 24 ore. Ogni volta che l alimentazione viene ripristinata, la batteria interna comincia la fase di ricarica. 2.2.3 Connessione con l Interfaccia di Comunicazione Se si utilizza il pannello remoto ad una distanza da 1.5m a 25m (cavo seriale 25m opzionale) dall UPS, fare quanto segue: Impostazione UPS: dal menu selezionare COMANDI premendo il tasto Enter con la freccia giù verificare che sia impostato su COMM=RS232. Eventualmente premere Enter per impostare. Assicurarsi che i due dip switch sulla scheda interfacce dell UPS siano in posizione RS232 (entrambi in basso). Connettere il cavo di comunicazione alla porta denominata RS232. Impostazione Pannello: 1 Posizionare i due dip switch in posizione Converter (tutti e due in alto). 2 Connettere il cavo di comunicazione alla porta denominata UPS RS232. 3 Connettere il cavo di alimentazione al pannello remoto. 4 Accendere il pannello remoto. Se si utilizza il pannello remoto ad una distanza da 25m a 100m dall UPS, fare quanto segue: Utilizzare i due connettori DB9 in dotazione e cablare il collegamento tramite un cavo CAT.5 schermato. Lato UPS EVO DSP TT-TM porta RS422 Lato Pannello Remoto porta RS488 Connettore DB9 Maschio 2 9 1 5 6 4 4 9 1 5 6 2 Connettore DB9 Femmina Impostazione UPS: dal menu selezionare COMANDI premendo il tasto Enter con la freccia giù selezionare RS232 e premere Enter per cambiare in RS485. Assicurarsi che i due dip switch sulla scheda interfacce dell UPS siano in posizione RS232 (entrambi in basso). Connettere il cavo di comunicazione alla porta denominata RS422. Impostazione Pannello: 1 Posizionare i due dip switch in posizione UPS (tutti e due in basso). 2 Connettere il cavo di comunicazione alla porta denominata Converter RS488. 3 Connettere il cavo di alimentazione al pannello remoto. 4 Accendere il pannello remoto. Pannello Remoto 19 Manuale Utente

ITALIANO 3 DISPLAY E TASTI Nell immagine sottostante è rappresentato, il pannello remoto con il quale è possibile monitorare lo stato dell UPS tramite la presenza di led, tasti e di ciò che è rappresentato sul display. Descrizione e funzioni di ogni componente del pannello remoto sono spiegate nei capitoli successivi. 3.1 LED Sono presenti 6 led di indicazione sul pannello remoto. Le loro funzioni sono: LINEA (Modalità Rete) Quando la rete è presente il led verde è attivo. Se siamo in una situazione di sottotensione, sovratensione o blackout il led verde lampeggia continuamente. BATTERIA (Modalità Batteria) Il led rosso non è attivo quando l Ups si trova in modalità rete, ma se siamo in una situazione di assenza rete, il messaggio MN ABNML è presente sul display LCD ed è presente un segnale acustico. Quando la capacità delle batterie è inferiore al 30 % il led continua a lampeggiare. BYPASS (Modalità Bypass) Il led giallo è attivo quando l ingresso è direttamente collegato all uscita (modalità Bypass) e il messaggio BYPACT è presente sul display LCD accompagnato da un segnale acustico. SOVRACCARICO (Sovraccarico > % 100) Questa indicazione è presente in una condizione di sovraccarico. Quando l UPS si trova in una situazione di sovraccarico il led verde lampeggia accompagnato da un segnale acustico e il messaggio OVERLOAD è presente sul display LCD. INVERTER Il led verde è attivo quando il carico è alimentato tramite l inverter. Manuale Utente 20 Pannello Remoto

ITALIANO CONDIZIONE DI ERRORE Se la temperatura dei moduli di potenza supera i limiti consentiti. Se la temperature di raffreddamento supera i limiti consentiti. Se la temperature delle batterie supera i limiti consentiti. Se è presente un malfunzionamento sulle ventole. Se il fusibile batterie è interrotto. Se il test batterie non è passato con successo. Se è presente un problema sul circuito inverter. Se è presente un problema sull uscita. Se sono presenti altri errori. In queste condizioni di errore il led si FAULT lampeggia accompagnato da un segnale acustico. 3.2 Tasti Sono presenti 4 tasti sul pannello remoto. I tasti hanno le seguenti funzioni: Tasto Questo tasto permette di mostrare tutte le informazioni memorizzate dalla scansione dell UPS e consente di adeguare alcuni valori. Le informazioni sono nel seguente ordine: LD1, LD2,LD3 : Potenza d uscita - [Corrente d uscita/corrente nominale] (%) Vsc1,Vsc2,Vsc3 : r,s,t Tensione d uscita sulle fasi (V) Isc1,Isc2,Isc3 : r,s,t Corrente d uscita sulle fasi (A) Fout : Frequenza d uscita (Hz) Vby1,Vby2,Vby3 : r,s,t Tensione sulle fasi in modalità Bypass (V) Vin1,Vin2,Vin3 : r,s,t Tensione d ingresso sulle fasi (V) Iin1,Iin2,Iin3 : r,s,t Corrente d ingresso sulle fasi (A) Fin : Frequenza d ingreso (Hz) Vbtp : Tensione totale di batterie (positivo) (V) Vbtn : tensione totale di batterie (negativo) (V) Tasto Questo tasto ha la stessa funzione del tasto, ma nel senso opposto. Tasto (Uscita) Questo tasto consente l uscita da un menu e l accesso ad un altro menu. Tasto (Conferma) Questo tasto consente l accesso ad un menu e la conferma di un impostazione. Pannello Remoto 21 Manuale Utente

ITALIANO 3.3 Display LCD Il display LCD mostra il tipo di modalità, lo stato, gli allarmi attivi e i messaggi relativi ad errori e numeri di fallimenti dell UPS. Come è rappresentato nella figura sotto, il messaggio che da la risposta relativa all UPS è rappresentato in una area specifica del display LCD. In questa sezione sono spiegati i messaggi e i loro significati. Manuale Utente 22 Pannello Remoto

ITALIANO Le abbreviazioni riguardanti lo stato dell UPS appaiono nello spazio OPERATION STATUS sul display LCDcome si vede sotto. Di seguito la lista delle abbreviazioni utilizzate. BTSTACT S.D.ACT BZ. ACT BYPSWON INV OFF RCT ACT RCT DIS INV DIS BYPMDIS GREENMD GENSET OFFSWON DCBUSCH NO COMM 1 : Test Batterie Attivo : Shut Down Attivo : Buzzer Attivo : Switch di Bypass attivo : Inverter Disattivato : Raddrizzatore Attivo : Raddrizzatore non Attivo : Inverter non Attivo : Modalità Bypass non Attivo : ECO Mode (Bypass Priority Mode) : GENSET Attivo : Switch UPSOFF Attivo : Carica DC Condensatori : Non è presente la comunicazione tra Pannello Remoto e UPS Le abbreviazioni per gli allarmi rilevanti riportati nello spazio ALARM sul display LCD sono i seguenti: OK MN ABNL BATT LOW UPSFAULT BYP V FA BYP V HI BYP V LO BYP SYNC BYP SEQ: INV TEMP OUT OVER BYP ACT. INV BLO. SBUS V F INP V HI INP V LO INP SYNC INP SEQ. RCT TEMP RCT OVER DCBUSVHI DCBUSVLO RCT BLO. BT DISCH DCBUSVFA TEMP HI BT TST F OVERLOAD WITH UPS 1 : Nessun Allarme : Alimentazione non normale : Tensione Batterie Bassa : Errore (vedi LED di FAULT) : Tensione di Bypass Fuori dai Limiti. : Tensione di Bypass Alta : Tensione di Bypass Bassa : Sincronizzazione Bypass : Sequenza Bypass : Inverter Surriscaldato : Sovraccarico in Uscita : Bypass Attivo : Inverter Bloccato : Tensione di Uscita Fuori dai Limiti : Tensione di Ingresso Alta : Tensione di Ingresso Bassa : Sincronizzazione Ingresso : Sequenza ingresso : Raddrizzatore Surriscaldato : Sovraccarico Raddrizzatore : Tensione DC Bus Alta : Tensione DC Bus Bassa : Raddrizzatore Bloccato : Batterie Scariche : Tensione DC Bus Fuori dai Limiti : Temperatura dell Ambiente Elevata : Test Batterie Fallito : Sovraccarico : Non è presente la comunicazione tra Pannello Remoto e UPS Note 1: Questi messaggi sono significativi solo se sono visualizzati allo stesso momento. Note 2: Nel caso si verifichino più allarmi allo stesso tempo, apparirà il codice che occupa l ultima posizione della riga. Pannello Remoto 23 Manuale Utente

ITALIANO Nella sezione PARAMETERS le abbreviazioni per i parametri ricercati, sono visibili utilizzando la chiave MODE. Questi possono essere elencati come segue: LD1, LD2,LD3 : Potenza d uscita - [Corrente d uscita/corrente nominale] (%) Vsc1,Vsc2,Vsc3 : r,s,t Tensione d uscita sulle fasi (V) Isc1,Isc2,Isc3 : r,s,t Corrente d uscita sulle fasi (A) Fout : Frequenza d uscita (Hz) Vby1,Vby2,Vby3 : r,s,t Tensione sulle fasi in modalità Bypass (V) Vin1,Vin2,Vin3 : r,s,t Tensione d ingresso sulle fasi (V) Iin1,Iin2,Iin3 : r,s,t Corrente d ingresso sulle fasi (A) Fin : Frequenza d ingreso (Hz) Vbtp : Tensione totale di batterie (positivo) (V) Vbtn : tensione totale di batterie (negativo) (V) Nella sessione VALUE è possibile scegliere i valori dei parametri tramite l uso dei tasti e. 3.4 Allarme Acustico Quando il segnale di FAULT si attiva e disattiva. Quando l UPS è in modalità batteria. Quando il sistema segnala un sovraccarico (overload, out over). Quando la tensione della batteria del pannello frontale è bassa. E udibile un segnale acustico ogni 2 secondi. Manuale Utente 24 Pannello Remoto

ITALIANO 4 D USO Premere il tasto per accedere al menu principale. 4.1 Allarme Acustico ON/OFF ********* REMOTE CONTROL Main Screen Remote Control Buzzer ON / OFF TOGGLE BUZZER? NO / YES YES Buzzer on / off 4.2 Test Batteria ON/OFF ********* REMOTE CONTROL x 1 Main Screen Batt. Test ON / OFF Str/Stp? NO / YES YES Battery Test Pannello Remoto 25 Manuale Utente

ITALIANO 4.3 Annullare Test Batteria ********* REMOTE CONTROL x 2 Main Screen Cancel Batt. Test Stop Batt Test? NO / YES YES Cancel Batt. Test 4.4 Shutdown dell UPS ********* REMOTE CONTROL x 2 Main Screen Shut Down UPS Turn Off UPS? NO / YES YES NO Are You Sure? NO / YES YES Shutdown UPS Manuale Utente 26 Pannello Remoto

ITALIANO 4.5 Controllo Numero Seriale e Data di Produzione dell UPS REMOTE CONTROL UPS IDITY Model: PD XXXkVA Version: 1.0 4.6 Stato del Pannello Remoto In questo menu, alcuni parametri come data/ora, il tipo di comunicazione, la versione del software, il monitoraggio della tensione delle batterie interne, la pulizia dello storico eventi e il contrasto del display LCD possono essere regolati. 4.6.1 Regolazione Data/Ora x 2 UPS IDITY RCMP STATUS RCMP Time / Date hh/mm/ss dd / mm CHANGE TIME? NO / YES In questo sotto-menu, l ora e la data del pannello remote possono essere regolate. I valori possono essere regolati tramite i tasti,. Per accedere al parametro successive (ex. dalla regolazione dell ora a quella dei minuti), premere il tasto una volta ed effettuare la regolazione con i tasti,. Dopo la regolazione del mese, premere il tasto ed esci dal menu data/ora. Per annullare, premere il tasto. Pannello Remoto 27 Manuale Utente

ITALIANO 4.6.2 Tipo di Comunicazione e Versione del Software x 2 UPS IDITY RCMP STATUS Comm. Via RS XXX SW Version X.XX 4.6.3 Stato delle batterie interne x 2 UPS IDITY RCMP STATUS x 2 Inter. Batt. XXX V %XXX Il pannello remote ha una batteria interna. In caso di mancanza di alimentazione, la batteria garantisce 4 ore di autonomia al pannello remote. Se la tensione della batteria è inferiore a 12V, l avviso Ibatt Low comparirà sul display. Se la tensione scende fino a 10V, Il pannello remoto si spegne automaticamente. Se la rete è presente la batteria si ricarica. Manuale Utente 28 Pannello Remoto

ITALIANO 4.6.4 Pulizia Storico Eventi x 2 UPS IDITY RCMP STATUS x 3 ERASE EV FILE ARE YOU SURE? NO / YES Tutto lo storico viene cancellato. Per completare il processo servono circa 30 secondi. 4.6.5 Regolazione Contrasto x 2 UPS IDITY RCMP STATUS CONTRAST x 4 Change Contrast XXX In questo menu, il contrasto del display LCD può essere regolato. La regolazione avviene tramite i tasti e. Per confermare premere il tasto. Per annullare premere il tasto. Pannello Remoto 29 Manuale Utente

ITALIANO 4.6.6 Storico Eventi x 3 RCMP STATUS EV FILE XXXXXXXXXXXXX KK- SS/DD GG/AA ALARM STRING XXXX XXXX XXXX In questa sessione sono presenti altri eventi visualizzabili. Per visualizzarli premere il tasto e successivamente. Quando accede al menu Event File, è presente l ultimo evento occorso. I parametri sono i seguenti: XXXXXX: Descrizione dello storico salvato. KK: Eventi salvati. SS: Evento occorso nel tempo. DD: Evento occorso in minuti. GG: Evento occorso in giorni. AA: Evento occorso in mesi. Puoi visualizzare l ultimo evento o i precedenti tramite i tasti,. Durante la visualizzazione degli eventi, se premi il pulsante, saranno mostrati alcuni parametri dell evento. Questi parametri sono mostrati in allegato e sono importanti per il servizio tecnico. Manuale Utente 30 Pannello Remoto