Residual current device 96x96mm

Documenti analoghi
Residual current device 96x96mm

Residual current device 96x96mm

Delta 72 - S. Residual current device 72 x7 2mm. Relè differenziale PROTEZIONE PROTECTION

Residual current device

Residual current device 72 x7 2mm

Residual current device 4 Module

Residual current device 2 Module

Residual current device 2 Module

Residual current device 4 Module

Delta D4 - F. Relè differenziale 4 Moduli. Residual current device 4 Module PROTEZIONE PROTECTION

Residual current device 96x96mm

Residual current device 4 Module

Delta D4 - I. Residual current device 4 Module. Relè differenziale 4 Moduli PROTEZIONE PROTECTION

Delta 72 - h. Relè differenziale. Residual current device 72 x 7 2mm PROTEZIONE PROTECTION

Residual current device 4 Module

Direct and pulsanting voltage or current digital meter 96x48 mm

Direct and pulsanting voltage or current digital meter 96x48 mm

D4E - Analog Meters for alternating current 4 module

DCL 86. DCL Relè di blocco Lock-out relay FOGLIO TECNICO / DATA SHEET APPLICAZIONE

Residual current device 4 Module

AQMrad Analog Meters for alternating current 48x48mm 72x72mm 96x96mm

AQMrad Analog Meters for alternating current 48x48mm

Tensione di monitoraggio Monofase / 1Ph Monitoring Voltage. Regolabile / Adjustable 0,1 s-10s,10% 1% del Valore di scala / of scale value

Relè differenziali di terra

CONTROLLORI PERMANENTI DELL ISOLAMENTO DI RETI ELETTRICHE IT

COMMUTAZIONE AUTOMATICA E la funzione che governa la commutazione tra due linee in un tempo regolabile fra 0,5 e 120 secondi.

RI-R60 DIPOSITIVO PER IL CONTROLLO PERMANENTE DELL ISOLAMENTO PER RETI ISOLATE IT

+ In. 4mA. 4mA. 20mA. 20mA. Indicatori Analogici - AQM per corrente continua 48x48mm 72x72mm 96x96mm

antifibrillazione selezionabile antifibrillation LPF IEC 62423, VDE 0664-T-100 protezione antiincendio/fire protection 300mA

Low voltage Network monitor 96x96mm

Relè differenziale MRCD di tipo B

MANUALE D USO INDICATORI DIGITALI / DIGITAL DISPLAY UNIT USER S MANUAL

RESYS M40 Relè differenziale di tipo A per partenze motori

Conto imp. Pulse Acquisition. Concentratore Remoto 4 moduli CONTEGGIO ENERGIA ENERGY COUNTING. 4 module RS485. gas kcal RS485. gas kcal RS485.

RM35S0MW Relè controllo della velocità RM35-S V AC/DC

Network monitor for low voltage 4 module

Power relay, single-phase network 2 Module

Relè differenziali 4. 01

Digital meter of: Voltage dc or ac Current dc or ac Frequency 72x72 mm

Carica batterie automatici

Nemo 72-L Network Monitor

STRUMENTI ANALOGICI ELETTRONICI ELECTRONIC ANALOGIC INSTRUMENTS

WIN 3 / ANA SAEL S.R.L. Load cells digital amplifier...english [Pag ] Amplificatore digitale per celle di carico...italiano [Pag.

Scala intercambiabile Exchangeable scale

Conto imp. Concentratore Remoto 4 moduli. Pulse Acquisition 4 module CONTEGGIO ENERGIA ENERGY COUNTING RS48. gas kcal. gas kcal. gas kcal 4...

MANUALE OPERATIVO / INSTRUCTION MANUAL IM200-IU v1.3 CT / CTD CT / CTD. Toroidal current transformers. Trasformatori di corrente toroidali. pag.

Network monitor for low voltage

ESECUZIONE DA INCASSO Tipo R2D 2 soglie di intervento. TA esterno. Sicurezza positiva. Tipo R3D 2 soglie di intervento. TA esterno.

Relè differenziali. I dettagli che fanno la differenza Un unica e completa gamma per la protezione differenziale

RM35HZ21FM Relè controllo frequenza RM35-HZ - intervallo:

Power relay, single-phase network 2 Module

Insulation monitor for hospital use 4 module

Relè differenziali. I dettagli che fanno la differenza Un unica e completa gamma per la protezione differenziale

Serie CMLD Condensatori DC Link e snubber DC Link & snubber capacitors

RM17TE. Schede dati dei prodotti Caratteristiche. Relè controllo multifunzione RM17-TA - intervallo: VAC. Presentazione

MOSAIC MOR4/MOR4S8 RELAY OUTPUT EXPANSION UNIT

RELÈ DIFFERENZIALI DELTA

Conto D k W h. Static Meter submetering applications Active Energy 1 module

WIN 3 / ETHERNET. Amplificatore digitale per celle di carico con interfaccia ETHERNET... ITALIANO [Pag. 2-3]

RE48AMH13MW Relè temp. ritardo - 2 funzioni - 0,02 s..300 h V CA - 2 OC

Network monitor for direct current 4 module

RM35TM50MW Relè controllo tensione motore e temperatura - RM35-T V AC/DC - 2NO

Schema dei collegamenti Main connection diagram S2 Caratteristiche tecniche Technical features S2 Dimensioni Dimensions S3 Opzioni Options S3

Network monitor for direct current 4 module

IMM Drukmat voor het beveiligen van gevaarlijke zones rondom machines. Indien men op de mat staat schakelt de mat de noodstop in.

INDICATORE MULTIFUNZIONE NETWORK MONITOR NT a Edizione / Edition pag.1/6 6 moduli/module DIN MF1CT4 MEASURE

Serie ET / ET Series

Static Meter submetering applications 4 module

20mA. 4mA. 20mA. 4mA. RQM - Analog Meters for direct current 48x48mm 72x72mm 96x96mm

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

SOMMATORE / SOTTRATTORE - SEPARAZIONE GALVANICA

SOLID STATE RELAY MODULES - 1 STAGE 3A WITH FUSE PROTECTION SOLID STATE RELAY MODULES - 4 STAGE 3A WITH FUSE PROTECTION

SENSORI INDUTTIVI M30 x 1,5 INDUCTIVE SENSORS M30 x 1,5

ELETTRONICA DUE AMPLIFICATORE PER FIBRE / FIBER SENSOR

Static Meter submetering applications 4 module

Idoneità ai climi Caldo umido, costante, secondo IEC Caldo umido, ciclico secondo IEC

WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]

ELETTRONICA DUE AMPLIFICATORE PER FIBRE / FIBER SENSOR FOTEK. ! Caratteristiche / Features

Static Meter submetering applications 4 module. Three-phase network, 3 and 4-wire Direct connection: three-phase 230(400) 240(415)V 63A V 63A

G4BM480V12ATL20. Dati tecnici. Controllo potenza reale sistemi monofase o trifase

RELÈ DIFFERENZIALI serie RDC

Codice : LEMC Hz

Strumenti di misura modulari

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003

Informazione Tecnica. 6. Relè differenziali di terra

G4BM400V12ATL20. Dati tecnici. Controllo potenza reale sistemi monofase o trifase

SPECIFICA TECNICA LEONARDO VA

Siemens S.p.A Apparecchi di controllo SENTRON. Aggiornamento Catalogo SENTRON 02/2012

COMPONENTI PER L ELETTRONICA INDUSTRIALE E IL CONTROLLO DI PROCESSO. Soglie di allarme per montaggio su guida DIN SERIE DAT5028-DAT5024

Nemo 72-L. Strumento multifunzione. Network monitor MULTIMISURA MULTIMETERING VISUALIZZA DISPLAY

Commutatori motorizzati 3KA71

SIMONAZZI F.LLI S.r.l. - S. ILARIO D ENZA (RE) ITALY - Tel Fax

ISTRUZIONI. Codice: LEMC30 v2.0 VOLTAGE Usa il QRcode per scaricare il foglio di istruzioni sul tuo smartphone/tablet.

ACCESSORI Accessories

Concentratore Impulsi, 12 ingressi, 4 mod. DIN, uscita RS485

Transcript:

PROTEZIONE PROTECTION Relè differenziale 96x96mm Applicazioni industriali onerose, con presenza di correnti distorte: inverter, variatori di velocità, carichi non lineari Filtro per componenti armoniche Non utilizzabile per la protezione delle persone in caso di contatti diretti Punto di intervento selezionabile 50mA 30A (18 portate) Visualizzazione istantanea percentuale di IΔ n Sicurezza positiva o negativa selezionabile in campo Test automatico permanente Relè di allarme + preallarme oppure relè allarme con doppio scambio Residual current device 96x96mm Heavy industrial applications with distorted current waveforms: inverters, variable speed drives, rectifiers, frequency regulators Filter for harmonics It cannot be used to protect people in case of direct contacts Selectable set point 50mA 30A (18 ranges) Instantaneous display as percentage of IΔ n Field-selectable negative or positive security (fail safe) Automatic permanent test Alarm relay + pre-alarm or alarm relay with double exchange Delta 96-F Segnalazione intervenuto allarme (LED rosso) Red LED for an occured alarm Indicazione istantanea della corrente differenziale Instantaneous display of earth leakage current Selettore portata x1 / x10 / x100 Range selector x1 / x10 / x100 Selezione punto di intervento IΔn Setting intervention threshold IΔn ~ Pulsante di ripristino Reset key Pulsante Test Test key Selettore stato relè uscita: ND (norm. diseccitato) sicurezza negativa Ne (norm. eccitato) sicurezza positiva Switch for state output relay: ND (norm. de-energised) negative security Ne (norm. energised) positive security Selezione tempo di intervento Setting intervention time Segnalazione apparecchio alimentato (LED verde) Green LED for fed meter Selettore: Selector: Al.2 allarme con 2 contatti SPDT Al.50% allarme + preallarme 50% IΔn Al.2 alarm with 2 SPDT contacts Al.50% alarm + 50% IΔn pre-alarm NT746 11-2017 4 a Ed. pag.1/5

PORTATE RANGES BLOCCO ELETTRICO ISTANTANEOUS FORMA D ONDA WAVEFORM FILTRO COMPONENTI ARMONICHE FILTER FOR HARMONICS NORMA DI RIFERIMENTO ACCORDING TO ALLARME ALARM VISUALIZZAZIONE IΔn DISPLAY USCITA RELE RELAY OUTPUT SICUREZZA positiva / negativa SECURITY positive / negative TEST RIPRISTINO RESET ALIMENTAZIONE AUSILIARIA AUXILIARY SUPPLY DIMENSIONI DIMENSIONS MODELLO MODEL 96-F CODICE CODE RD2G21... NOTA TECNICA TECHNICAL NOTE NT746 19: 0,03...30A 18: 0,05...30A t=0s a/at IΔn 30mA Sinusoidale (tipo AC) Sinusoidal (AC type) Pulsante parzializzata con componente continua (tipo A) Chopped pulsating with superimposed dc (A type) Selezionabile Selectable Fisso Fixed EN60947-2 IEC60947-2 1 Uscita Relè 1 Relay Output 2 Uscite Relè 2 Relays Output 1 Uscita + Preallarme 1 Output + Pre-alarm Barra LED LED Bargraph Display SPDT SPDT + SPST 2 SPDT Selezionabile Selectable Locale Local Remoto Remote Automatico Automatic Locale Local Remoto Remote Automatico Automatic 230Vca/ac 24-48-115-240-400Vca/ac 20...150Vcc/dc 10...36Vcc/dc 2 Moduli 2 Module 4 Moduli 4 Module 48 x 48 mm 72 x 72 mm 96 x 96 mm In alternativa On choice Non realizzabile con al.aus.20...150vcc-48vca Not available with aux. supply 20...150Vdc-48Vac NT746 11-2017 4 a Ed. pag.2/5

CODICI DI ORDINAZIONE ORDERING CODE RD2G211B RD2G212B RD2G213B RD2G214B RD2G215B RD2G21HB AL. AUSILIARIA AUX. SUPPLY 24V ca/ac 115V ca/ac 230V ca/ac 240V ca/ac 4400V ca/acr 20...150Vcc/dc + 48V ca/ac INGRESSO Inserzione: linea bassa tensione, con trasformatore serie TD Forma d onda IΔn: sinusoidale (tipo AC) o pulsante parzializzata con componente continua (tipo A) in accordo con EN60947-2 (annesso B e M) ed. VIII (2007) / IEC60947-2 Frequenza nominale fn: 50Hz Frequenza di funzionamento: 47...63Hz Filtro per componenti armoniche (applicazioni industriali, non utilizzabile per la protezione delle persone). INPUT Connection: low voltage lines, with series TD transformer Waveform I n: sinusoidal (type AC) or chopped pulsating with superimposed d.c. (type A) according to EN60947-2 (annex B and M) IEC60947-2 Rated frequency fn: 50Hz Working frequency: 47...63Hz Filter for harmonic (industrial application, it cannot be used to procted people) PREDISPOSIZIONE Punto di intervento IΔn: selezionabile con potenziometro a 7 posizioni, 3 gamme x1 - x10 - x100 Portate IΔn: vedi tabella SET UP Current set point I n: selectable by 7-position potentiometer, 3 ranges x1 - x10 - x100 Ranges I n: see table 0,05 0,075 0,1 0,15 0,2 0,3 X1 50mA 75mA 100mA 150mA 200mA 300mA IΔn X10 500mA 750mA 1A 1,5A 2A 3A X100 5A 7,5A 10A 15A 20A 30A Corrente differenziale di non intervento: 0,5 IΔn Tempo di intervento t: selezionabile con potenziometro a 7 posizioni Campo regolazione t: 0-0,15-0,25-0,5-1 - 2,5-5 secondi Non-operating residual current : 0,5 I n Intervention time t: selectable by 7 position potentiometer Adjustable range t: 0-0,15-0,25-0,5-1 - 2,5-5 seconds Soglia intervento (IΔn) Set point (IΔn) Ritardo impostato t(s) Selected delay t(s) Tempo non intervento @ 2IΔn Non-operating time at @ 2IΔn Max. ritardo @ 5IΔn Max. delay @ 5IΔn 0,05...30A 0,15s 0,25s 0,5s 1s 2,5s 5s 0,15s 0,25s 0,5s 1s 2,5s 5s 0,24s 0,35s 0,63s 1,20s 2,80s 5,50s Selettore Al.2 - Al.50% Al.2: relè di allarme con doppio scambio Al.50%: relè di allarme + preallarme 50% IΔn Il relè contrassegnato 60-61 - 62 è un preallarme con soglia intervento fissa, pari a 50% del valore di IΔn selezionato Switch Al.2 - Al.50% Al.2: alarm relay with double exchange Al.50%: alarm relay + pre-alarm 50% IΔn Relay marked 60-61 - 62 is a pre-alarm state with fixed intervention threshold, equal 50% of selected IΔn value SEGNALAZIONE SIGNALING NT746 11-2017 4 a Ed. pag.3/5 Strumento alimentato: LED verde "ON" Valore istantaneo IΔn: 4 LED gialli, 20-30 - 40-50% del valore IΔn impostato Intervento allarme: LED rosso "TRIP" + commutazione relè TRIP Interruzione collegamenti relè - toroide: lampeggio LED rosso "TRIP" + commutazione relè TRIP Preallarme: commutazione relé 50% I n CONTROLLO Test manuale: verifica l'efficienza del relè differenziale Locale: pulsante frontale Remoto: chiusura contatto esterno (Non realizzabile con aux cc e con Uaux 48Vca) Test automatico permanente: verifica la continuità del collegamento relè differenziale - toroide Power ON: green LED "ON" Instantaneous value IΔn: 4 yellow LED's, 20-30 - 40-50% of set IΔn value Alarm intervention: red LED "TRIP" + TRIP relay switching Ring current transformer-relay connection failure: red LED "TRIP" blinking + TRIP relay switching Pre-alarm: 50% I n relay switching CONTROL Manual test: it verifies the residual current relay perfect working Local: front key Remote: by external contact closing (Not available with dc supply and Uaux 48Vac) Automatic continuous test: it verifies the integrity of the connection between relay and ring core

ALLARME Memorizzazione intervento: LED rosso "TRIP" + autoritenuta relè Ripristino (reset): manuale Manuale locale: pulsante frontale Manuale remoto: chiusura contatto esterno Ripristino inibito con corrente differenziale persistente: > 50% IΔn ALARM TRIP state memorization: red LED "TRIP" + relay self-retaining Reset: manual Local manual: front key Remote manual: external contact closing Inhibited reset with persistent residual current: > 50% IΔn USCITA Allarme con doppio scambio (Al.2) Relè TRIP : 2 contatti di scambio SPDT Allarme + preallarme (Al.50%) Relè TRIP : 1 contatto di scambio SPDT Relè 50% I n: 1 contatto di scambio SPDT (sicurezza negativa) Sicurezza negativa/condizionata (relè normalmente diseccitato) oppure positiva/incondizionata (relè normalmente eccitato): selezionabile tramite dip switch OUTPUT Alarm relay with double exchange (Al.2) TRIP relay: 2 SPDT contacts Alarm + pre-alarm (Al.50%) TRIP relay: 1 SPDT contact 50% I n relay: 1 SPDT contact (negative security) Negative security (normally de-energised relay) or positive security fail safe (normally energised relay): selectable by dip switch ALIMENTAZIONE AUSILIARIA Valore nominale Uaux: 48-115V - 230V - 240V - 400V Variazione ammessa: 0,85...1,1Uaux - 40...60V (Uaux 48V) Frequenza nominale: 50Hz Variazione ammessa: 47...63Hz Autoconsumo: 2,5VA Valore nominale Uaux: 20...150Vcc Protezione contro l inversione di polarità Autoconsumo: 2,5W Insensibilità ai buchi di tensione con durata fino a 150ms (Uaux nominale) AUXILIARY SUPPLY Rated value Uaux: 48-115V - 230V - 240V - 400V Tolerance: 0,85...1,1Uaux - 40...60V (Uaux 48V) Rated frequency: 50Hz Tolerance: 47 63Hz Rated burden: 2,5VA Rated value Uaux: 20...150Vdc Protected against incorrect polarity Rated burden: 2,5W Immunity to short interruption of supply voltage up to 150ms (Rated Uaux) SOLAMENTO 60947-1) Categoria di installazione: III Grado di inquinamento: 2 Tensione di riferimento per l isolamento: 450V Prova di tensione a impulso 5kV 1,2/50µs 0,5J Circuiti considerati: ingresso, uscita relè, alimentazione ausiliaria Prova a tensione alternata 2,5kV valore efficace 50Hz/1min Circuiti considerati: ingresso, uscita relè, alimentazione ausiliaria Prova a tensione alternata 4kV valore efficace 50Hz/1min Circuiti considerati: tutti i circuiti e massa PROVE DI COMPATIBILITA ELETTROMAGNETICA Prove di emissione in accordo con EN / IEC 60947-2 Prove di immunità in accordo con EN / IEC 60947-2 CONDIZIONI AMBIENTALI Temperatura di impiego: -5 50 C Temperatura limite di funzionamento: -10 55 C Temperatura di magazzinaggio: -40 70 C Umidità relativa (IEC60755): 50% (valore massimo a 40 C) Adatto all utilizzo in clima tropicale Massima potenza dissipata 1 : 2W 1 Per il dimensionamento termico dei quadri CUSTODIA Custodia: incasso (foratura pannello 92x92mm) Frontale: 96x96mm Profondità: 80mm Connessioni: faston 6,3x0,8mm Materiale custodia: policarbonato autoestinguente Grado di protezione (EN/IEC 60529): IP40 frontale, IP20 morsetti Peso: 280 grammi (EN/IEC INSULATION (EN/IEC 60947-1) Installation category: III Pollution degree: 2 Insulation reference voltage: 450V Impulse voltage test 5kV 1,2/50μs 0,5J Considered circuits: input, relay output, auxiliary supply A.C. voltage test 2,5kV r.m.s. 50Hz/1 min Considered circuits: input, relay output, auxiliary supply A.C. voltage test 4kV r.m.s. 50Hz/1 min Considered circuits: all circuits and earth TESTS FOR ELECTROMAGNETIC COMPATIBILITY Emission tests according to EN / IEC 60947-2 Immunity tests according to EN / IEC 60947-2 ENVIRONMENTAL CONDITIONS Nominal temperature range: -5 50 C Limit temperature range: -10 55 C Limit temperature range for storage: -40 70 C Relative humidity (IEC60755): 50% (highest value at 40 C) Suitable for tropical climates Max. power dissipation 1 : 2W 1 For switchboard thermal calculation HOUSING Housing: flush mounting (panel cutout 92x92mm) Front frame: 96x96mm Depth: 80mm Connections: fast-ons 6,3x0,8mm Housing material: self-extinguishing policarbonate Protection degree (EN/IEC 60529): IP40 front frame, IP20 terminals Weight: 280 grams NT746 11-2017 4 a Ed. pag.4/5

NT746 11-2017 4 a Ed. pag.5/5 La I.M.E. S.p.A. si riserva in qualsiasi momento, di modificare le caratteristiche tecniche senza darne preavviso. / I.M.E. S.p.A. reserves the right, to modify the technical characteristics without notice. SCHEMI D INSERZIONE WIRING DIAGRAMS S 291/123 S 291/86 TRIP RESET TEST TRANSFORMER AUX. TRIP Al.50% RESET TEST TRANSFORMER AUX. INPUT SUPPLY INPUT SUPPLY (+) ( ) (+) ( ) 19 18 17 60 61 62 4 6 1 3 2 20 21 19 18 17 60 61 62 4 6 1 3 2 20 21 Al.2 B A L1 L2 L3 N Al.50% DIMENSIONI DIMENSIONS 92 96 92 96 80 12 B A L1 L2 L3 N