Bi2+ SLR+ INVERTER FAN COIL WITH RADIANT PANEL

Dimensione: px
Iniziare la visualizzazioe della pagina:

Download "Bi2+ SLR+ INVERTER FAN COIL WITH RADIANT PANEL"

Transcript

1 Bi2+ SLR+ INVERTER FAN COIL WITH RADIANT PANEL PLUSES INVERTER SYSTEM The onboard tangential fan is driven by an inverter DC motor, thus the Bi2+ power consumption can be reduced up to 60% compared with the traditional AC currents. The electronic control adjusts the fan speed depending on the thermal load and allows therefore to constantly minimize the electrical consumption to a minimum of 3W. RADIANT TUBE+ Once the set point is reached with the fan effect, it is maintained with the radiant effect only, thus with just 1W of electrical consumption. Radiant tube+ allows to increase the heat exchange, thanks to a direct contact with the front panel. COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2+ is only 12.9 cm deep, versus the cm of a traditional fan coil. SILENT SYSTEM Silence is guaranteed by the DC motor, that always minimizes the fan speed depending on the set point. The on board control manages the SLEEP function disabling the fan operation and turning Bi2+ into a radiator. HE COIL High efficiency coil allows to increase the heat exchange efficiency by 5% compared with a traditional coil. The maximization of the heat exchange and the optimization of the temperature profiles lead to a higher air outlet temperature, allowing their use in every low water temperature comfort system. METAL FRAME The exquisite look, its lightness and the solidity of Bi2+ are design characteristics made possible by the painted metal frame and the aluminum grid.

2 FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING ONLY 12.9 CM DEEP RANGE INCLUDES 5 MODELS: SLR+ 200, SLR+ 400, SLR+ 600, SLR+ 800, SLR POWER INPUT AT MINIMUM SPEED: from 3 W ELECTRONIC CONTROL ON BOARD (choose between independent electronic control or remote control) SLEEP FUNCTION CLASS A: thanks to the inverter motor, to the high performing tangential fan and to the efficient heat exchange, the products of the Bi2+ range belong to the energy efficiency class A ** INSTALLATION VERSATILITY: on wall or floor standing 1) Electrothermal fuse 2) Tube radiant panel 3) HE Coil 4) High effi ciency tangential fan 5) DC inverter motor 6) Electronic control on unit 7) Automatic modulating fan speed control for maximum comfort and minimum consumption. THERMOGRAPHY COMPARING FAN RADIATOR WITH TRADITIONAL PLATE AND FAN RADIATOR WITH RADIATING PANEL OS RADIANT TUBE+ (conditions: room air 20 C, inlet water 50 C)

3

4

5 Bi2+ SL+ INVERTER FAN COIL PLUSES COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2+ is only 12.9 cm deep, versus the cm of a traditional fan coil. INVERTER SYSTEM The onboard tangential fan is driven by an inverter DC motor, thus the Bi2+ power consumption can be reduced up to 60% compared with the traditional AC currents. The electronic control adjusts the fan speed depending on the thermal load and allows therefore to constantly minimize the electrical consumption to a minimum of 3W. SILENT SYSTEM Silence is guaranteed by the DC motor, that always minimizes the fan speed depending on the set point. The on board control manages the SLEEP function disabling the fan operation. HE COIL High efficiency coil invented allows to increase the heat exchange efficiency by 5% compared with a traditional coil. The maximization of the heat exchange and the optimization of the temperature profiles lead to a higher air outlet temperature, allowing their use in every low water temperature comfort system. METAL FRAME The exquisite look, its lightness and the solidity of Bi2+ are design characteristics made possible by the painted metal frame and the aluminum grid.

6 FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING ONLY 12.9 CM DEEP RANGE INCLUDES 5 POWER MODELS: SL+ 200, SL+ 400, SL+ 600, SL+ 800, SL POWER INPUT AT MINIMUM SPEED: from 3 W ELECTRONIC CONTROL ON BOARD choose between independent electronic control or remote control) CLASS A: thanks to the inverter motor, to the high performing tangential fan and to the efficient heat exchange, the products of the Bi2+ range are classified in the energy efficiency class A INSTALLATION VERSATILITY: on wall or floor standing 1) Electrothermal fuse 2) HE Coil 3) High effi ciency tangential fan 4) DC inverter motor 5) Electronic control on unit 6) Automatic modulating control of fan speed for maximum comfort and minimum consumption. EASY MAINTENANCE: easy-to-remove air filters and front access to the fan make cleaning easier.

7

8

9 Bi2+ SLR FAN COIL WITH RADIANT PLATE PLUSES RADIANT TECHNOLOGY Radiant heating thanks to the installed radiant plate which lets reach the desired temperature faster. The special Calostat valve, standard on all units, enables water to pass into both heat exchange coil and radiant plate. FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING ONLY 12.9 CM DEEP RANGE INCLUDES 5 MODELS: SLR 200, SLR 400, SLR 600, SLR 800, SLR 1000 DISPONIBILE NEI COLORI AVAILABLE IN TWO VERSIONS: 2 PIPES 4 PIPE WITH GRID FULL FLAT* COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2 is only 12.9 cm deep, versus the cm of a traditional fan coil. AIR SYSTEM The structure of the fan and the electronic motor that modulates its speed ensure extremely uniform air distribution and homogeneous room temperature. METAL FRAME The exquisite look, its lightness and the solidity of Bi2 are design characteristics made possible by the painted metal frame and the aluminum grid. * FULL FLAT VERSION: innovative model with revolutionary design. Th e fi rst Bi2 in which the grid is replaced by a small motor-driven movable panel that activates when the unit is switched on and moves back when it is switched off. Th e Full Flat version is for vertical installation only. INSTALLATION VERSATILITY: on wall or floor standing EASY MAINTENANCE: easy-to-remove air filters and front access to the fan make cleaning easier.

10 1) Electrothermal valve 2) Radiant plate 3) Coil 4) Tangential fan

11

12

13 Bi2+ SL FAN COIL PLUSES COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2 only 12.9 cm deep, versus the cm of a traditional fan coil. AIR SYSTEM The structure of the fan and the electronic motor that modulates its speed ensure extremely uniform air distribution and homogeneous room temperature. METAL FRAME The exquisite look, its lightness and the solidity of Bi2+ are design characteristics made possible by the painted metal frame and the aluminum grid. * FULL FLAT VERSION: innovative model with revolutionary design. The first Bi2 in which the grid is replaced by a small motor-driven movable panel that activates when the unit is switched on and moves back when it is switched off. The Full Flat version is for vertical installation only. INSTALLATION VERSATILITY: on wall or floor standing FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING ONLY 12.9 CM DEEP EASY MAINTENANCE: easy-to-remove air filters and front access to the fan make cleaning easier. RANGE INCLUDES 5 MODELS: SL 200, SL 400, SL 600, SL 800, SL 1000 AVAILABLE COLOURS AVAILABLE IN TWO VERSIONS: 2 PIPES 4 PIPE WITH GRID FULL FLAT* ** Ceiling installation: only for BI2 SL with grill

14 1) Electrothermal valve 2) Coil 3) Tangential fan

15

16

17 Bi2+ SLN NANO FAN COIL PLUSES COMPACT TECHNOLOGY Constant attention to detail, design and engineering of components: this is how we conceive, design and create products with extremely compact dimensions that reduce space requirements to the minimum. Bi2 nano is just 12.9 cm deep, compared to cm of traditional fan coil units, and just 42.8 cm high THE RANGE INCLUDES 5 POWER MODELS: SLN 200, SLN 400, SLN 600, SLN 800, SLN INSTALLATION VERSATILITY: on wall, floor or ceiling. SLN has been designed to be installed in systems where the unit cannot be wall-mounted (glass walls, architectural facades). AIR SYSTEM The structure of the fan and the speed-modulating electronic motor guarantee extremely uniform air distribution and homogeneous temperature in every part of the room. EASY MAINTENANCE: easy-to-remove air filters and front fan access make cleaning easier Version without radiant panel for vertical and horizontal installation.* METAL FRAME The clean shape, lightness and solidity of Bi2 are design features achieved with the special painted metal shell and frame and the aluminium grill. FEATURES COOLS, DEHUMIDIFIES, HEATS AND FILTERS JUST 12.9 CM DEEP *For horizontal installation in cooling mode, the unit must be combined with a drain pan kit.

18

19

20 Bi2 SLI CONCEALED FAN COIL FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING ONLY 12.6 CM DEEP RANGE INCLUDES 5 MODELS: SLI 200, SLI 400, SLI 600, SLI 800, SLI 1000 INSTALLATION VERSATILITY: on wall, floor standing or ceiling PLUSES COMPACT TECHNOLOGY Constant care is devoted to every detail, to design and to component engineering. This is how we plan, design and create products with extremely compact shapes that allow you to minimize space requirements. This streamlined design makes the SLI model a space saving unit. Without the shell the thickness of the unit is only 12.6 cm and, thanks to the flush mounting kit, it can be fully concealed into the building. AIR SYSTEM The structure of the fan and the electronic motor that modulates its speed ensure extremely uniform air distribution and homogeneous room temperature. MODULAR BOX A panel system designed especially for modular plasterboard solutions. With this special kit the product can be totally concealed inside drywalls. EASY MAINTENANCE: easy-to-remove air filters and front access to the fan make cleaning easier. AVAILABLE IN TWO VERSIONS: 2 PIPES 4 PIPES

21

22

23

24

25

26

27

28

29 SLR smart Total flat fan coil with radiant panel Design by S. Ercoli & A. Garlandini 26 RADIANT TUBE+ Once the set point is reached with the help of the fan, the temperature is maintained through the radiant effect only, with no electrical consumption. The Radiant Tube+ Technology allows to increase the heat exchange thanks to the direct contact with the front panel, to decrease consistently the fan coil weight, to diminish the thermal inertia, while maximising the radiant effect on the whole panel. AIR SYSTEM The structure of the fan and the electronic motor that modulates its speed ensure extremely uniform air distribution and homogeneous room temperature. AL COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2 is only 12.9 cm deep, versus the cm of a traditional fan coil. 12,9 cm METAL FRAME The exquisite look, its lightness and the solidity of Bi2 are design characteristics made possible by the painted metal frame and the aluminum grid. SILENT SYSTEM The tangential fan, in comparison to traditional fans, ensures the minimum noise level combined with maximum air circulation. FLAT DESIGN No anti-aesthetical front grid. Complete integration with the building.

30 FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING Compact: only 12.9 cm deep The range includes 5 models: SLR smart 200, SLR smart 400, SLR smart 600, SLR smart 800, SLR smart 1000 Total flat design: no anti-aesthetical front grid. Complete integration with the building. Installation versatility: on wall or floor standing THERMOGRAPHY COMPARISON BETWEEN FAN COIL WITH TRADITIONAL RADIANT PLATE AND WITH THE TUBE RADIANT PANEL TUBE + (at the following condition: air temperature 20 C, water inlet 50 C) Other radiant devices Tube radiant panel Wall installation. Floor installation. 12,9 cm TECHNICAL FEATURES Electrothermal fuse Tube Radiant Panel Coil High efficiency tangential fan

31 BI2 2 pipes SLR smart version with radiant panel MODEL SLR smart 200 SLR smart 400 SLR smart 600 SLR smart 800 SLR smart 1000 White - Version Full-flat code BI2 2 pipes SLR smart version with radiant panel MODEL SLR smart 200 SLR smart 400 SLR smart 600 SLR smart 800 SLR smart 1000 (a) Total cooling capacity kw 0,83 1,76 2,63 3,33 3,81 Sensible cooling capacity kw 0,62 1,27 1,96 2,65 3,01 Water flow rate l/h Water pressure drops kpa 7,2 8,4 22,5 18,6 24,9 (b) Heating capacity 50 C kw 1,16 2,48 3,42 4,47 5,22 Water flow rate (50 C) l/h Water pressure drops (50 C) kpa 3,5 6,4 16,3 16,7 19,9 (c) Heating capacity kw 2,03 4,21 5,86 7,61 8,93 Water flow rate (70 C) l/h Water pressure drops (70 C) kpa 3,7 6,4 14,3 15,3 19,1 Max. static heating capacity (50 C) W Max. static heating capacity (70 C) W Coil water content l 0,47 0,8 1,13 1,46 1,8 Radiator plate water content l 0,9 1,3 1,7 2,1 2,4 Maximum operating pressure bar Water pipe fittings inches in Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 (d) Air flow rate max m 3 /h (d) Air flow rate min m 3 /h Supply voltage V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Max power input A 0,11 0,24 0,25 0,26 0,27 Max power input at minimum speed W (g) Max air flow sound pressure db(a) (g) Min. air flow sound pressure db(a) TECHNICAL DATA A D VERSION SLR smart (with radiant panel) SLR smart 200 SLR smart 400 SLR smart 600 SLR smart 800 SLR smart 1000 B C A mm B mm C mm D mm E mm Weight kg 13,5 15,5 19,5 22,5 25,5 E (a) Water temperature at coil inlet 7 C, water temperature at coil outlet 12 C, Room temperature 27 C db and 19 C wb (b) Water temperature at coil inlet 50 C, water flow rate as for cooling + plate, ambient air temperature at inlet 20 C. (c) Water temperature at coil inlet 70 C, water temperature at coil outlet 60 C, ambient air temperature at inlet 20 C. (d) Air flow measured with clean filters. (g) Sound pressure measured according to the ISO 7779.

32 SLR smart Model with radiant panel for vertical installation only CONFIGURATIONS 29 1 CONTROL KIT B0658 or B0659 or B0371 or B0543 or B B PLUMBING KIT B0641 or B0205 or B DESIGN KIT B0682 or B0683 or B0677 / B0681

33 Total flat fan coil Design by S. Ercoli & A. Garlandini 30 SILENT SYSTEM The tangential fan, in comparison to traditional fans, ensures the minimum noise level combined with maximum air circulation. AIR SYSTEM The structure of the fan and the electronic motor that modulates its speed ensure extremely uniform air distribution and homogeneous room temperature. COMPACT TECHNOLOGY Means constant care to every detail, to design and to components engineering. Products are therefore invented, designed and created with extremely compact sizes, without unnecessary dimensions. Bi2 is only 12.9 cm deep, versus the cm of a traditional fan coil. 12,9 cm AL METAL FRAME The exquisite look, its lightness and the solidity of Bi2 are design characteristics made possible by the painted metal frame and the aluminum grid. FLAT DESIGN No anti-aesthetical front grid. Complete integration with the building.

34 FEATURES COOLING, DEHUMIDIFYING, HEATING AND AIR CLEANING Compact: only 12.9 cm deep The range includes 5 power models: SL smart 200, SL smart 400, SL smart 600, SL smart 800, SL smart 1000 Total flat design: no anti-aesthetical front grid. Complete integration with the building. Installation versatility: on wall or floor standing Wall installation. Floor installation. Ceiling installation. 12,9 cm TECHNICAL FEATURES Electrothermal fuse Coil 1 3 High efficiency tangential fan 2 3

35 BI2 2 pipes SL smart version without radiant panel MODEL SL smart 200 SL smart 400 SL smart 600 SL smart 800 SL smart 1000 White code BI2 2 pipes SLR smart version without radiant panel MODEL SL smart 200 SL smart 400 SL smart 600 SL smart 800 SL smart 1000 (a) Total cooling capacity kw 0,83 1,76 2,63 3,33 3,81 Sensible cooling capacity kw 0,62 1,27 1,96 2,65 3,01 Water flow rate l/h Water pressure drops kpa 7,2 8,4 22,5 18,6 24,9 (b) Heating capacity 50 C kw 1,09 2,35 3,19 4,10 4,86 Water flow rate (50 C) l/h Water pressure drops (50 C) kpa 5,7 6,6 16,3 14,0 18,3 (c) Heating capacity kw 1,89 3,99 5,47 6,98 8,31 Water flow rate (70 C) l/h Water pressure drops (70 C) kpa 6,7 7,6 16,1 14,0 19,8 Coil water content l 0,47 0,8 1,13 1,46 1,8 Maximum operating pressure bar Water pipe fitting inches in Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4 (d) Air flow rate max m 3 /h (d) Air flow rate min m 3 /h Supply voltage V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Max current consumption A 0,11 0,24 0,25 0,26 0,27 Max power input W (g) Max air flow sound pressure db(a) (g) Min. air flow sound pressure db(a) TECHNICAL DATA A D B C E VERSION SL smart (without radiant panel) SL smart 200 SL smart 400 SL smart 600 SL smart 800 SL smart 1000 A mm B mm C mm D mm E mm Weight kg 11, ,5 18,5 21,5 (a) Water temperature at coil inlet 7 C, water temperature at coil outlet 12 C, Room temperature 27 C db and 19 C wb. (b) Water temperature at coil inlet 50 C, water flow rate as for cooling + plate, ambient air temperature at inlet 20 C. (c) Water temperature at coil inlet 70 C, water temperature at coil outlet 60 C, ambient air temperature at inlet 20 C. (d) Air flow measured with clean filters. (g) Sound pressure measured according to the ISO 7779.

36 SL smart Model without radiant panel for vertical or horizontal installation only. * CONFIGURATIONS 33 1 CONTROL KIT B0658 or B0659 or B0371 or B0543 or B B0373 or B B0151 or B PLUMBING KIT B0641 or B0205 or B DESIGN KIT B0682 or B0683 or B0677 / B0681 * For the horizontal installation in cooling mode is necessary the drain pan kit.

37 Indice Index Ventilconvettori a parete Wall fan coils version Modelli da 2,1 a 4,7 kw From 2,1 to 4,7 kw models pag. 180 Ventilconvettori a cassette Cassette fan coils version Modelli da 2,6 a 7,3 kw From 2,6 to 7,3 kw models pag. 182 Ventilconvettori Silence THIN con mobile Silence THIN covered fan coils version Modelli da 0,8 a 3,3 kw From 0,8 to 3,3 kw models pag. 184 Ventilconvettori Silence THIN ad incasso Silence THIN built-in fan coils version Modelli da 0,8 a 2,6 kw From 0,8 to 2,6 kw models pag. 184 Ventilconvettori Silence con mobile Silence THIN covered fan coils version Modelli da 1,5 a 7 kw From 1,5 to 7 kw models pag. 199 Ventilconvettori Silence ad incasso Silence THIN built-in fan coils version Modelli da 1,5 a 7 kw From 1,5 to 7 kw models pag. 199 Accessori ventilconvettori Accessories fan coils Per modelli Silence THIN For Silence THIN models pag. 193 Per modelli Silence For Silence models pag. 211

38 Ventilconvettori / Fan coils Ventilconvettore a parete ad acqua Water CLIMATIZZATORE wall fan coil SILENCE EGWW Wall mounted air conditioners Codice Code Prezzo Price Euro 400,00 440,00 Modello Model EGWW-0712 EGWW-1012 Capacità di raffreddamento max velocità Cooling capacity max speed (1) Total kw 2,15 2,80 Sensible kw 1,82 2,48 Capacità di raffreddamento med velocità Cooling capacity med speed (1) Total kw 1,85 2,00 Sensible kw 1,60 1,75 Capacità di raffreddamento min velocità Cooling capacity min speed (1) Total kw 1,65 1,75 Sensible kw 1,45 1,55 Portata d acqua max velocità Water flow max speed (1) l/h Perdita di carico max velocità Water pressure drop max speed (1) kpa Capacità di riscaldamento max velocità Heating capacity max speed (2) kw 2,70 3,60 Capacità di riscaldamento med velocità Heating capacity med speed (2) kw 2,30 2,55 Capacità di riscaldamento min velocità Heating capacity min speed (2) kw 1,98 2,20 Perdita di carico max velocità Water pressure drop max speed (2) kpa 9 15 max m 3 /h Portata d aria Air flow med m 3 /h min m 3 /h Tensione alimentazione Power supply V/Ph/Hz 230/1/50 Potenza assorbita Total power absorbed W Corrente assorbita Total current A 0,25 0,26 Livello di pressione sonora Noise pressure level max db(a) 35 (45) 42 (52) campo aperto * (**) free field * (**) med db(a) 32 (42) 32 (42) min db(a) 28 (38) 29 (39) Dimensioni e pesi Weight and dimensions Dimensioni Dimensions LxHxP mm 845x270x x270x180 Peso Weight kg Attacchi ingresso e uscita acqua Inlet and outlet connections Øe 12 rame/copper (1) Dati riferiti alle seguenti condizioni: acqua 7/12 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. (*) Pressione sonora rilevata in ambiente di 100 m 3, a 1,5 m di distanza e tempo di riverbero 0,3 s. (**) Potenza Sonora in accordo alla normative Eurovent 8/2. Nota: L acqua che circola nello scambiatore non deve superare i 60 C. (1) Data referred to the following conditions: water 7/12 C and inlet air temperature 27 C d.b. / 19 C w.b.. (2) Data referred to the following conditions: inlet water 50 C and inlet air temperature 20 C d.b. / 15 C w.b.. (*) Sound pressure level, in a 100 m 3 room, 1.5 m distance and reverberating time of 0.3 s. (**) Sound Power in accordance with regulations Eurovent 8/2. Note: The water circulating in the exchanger must not exceed 60 C. L P H

39 Ventilconvettori / Fan coils Ventilconvettore a parete ad acqua Water wall fan coil SILENCE EGWW Codice Code Prezzo Price Euro 555,00 580,00 Modello Model EGWW-1312 EGWW-1512 Capacità di raffreddamento max velocità Cooling capacity max speed (1) Total kw 4,00 4,70 Sensible kw 3,40 3,60 Capacità di raffreddamento med velocità Cooling capacity med speed (1) Total kw 3,40 3,90 Sensible kw 2,90 3,30 Capacità di raffreddamento min velocità Cooling capacity min speed (1) Total kw 3,10 3,35 Sensible kw 2,60 2,85 Portata d acqua max velocità Water flow max speed (1) l/h Perdita di carico max velocità Water pressure drop max speed (1) kpa Capacità di riscaldamento max velocità Heating capacity max speed (2) kw 4,90 5,80 Capacità di riscaldamento med velocità Heating capacity med speed (2) kw 4,20 4,85 Capacità di riscaldamento min velocità Heating capacity min speed (2) kw 3,80 4,15 Perdita di carico max velocità Water pressure drop max speed (2) kpa max m 3 /h Portata d aria Air flow med m 3 /h min m 3 /h Tensione alimentazione Power supply V/Ph/Hz 230/1/50 Potenza assorbita Total power absorbed W Corrente assorbita Total current A 0,34 0,35 Livello di pressione sonora Noise pressure level max db(a) 45 (55) 50 (60) campo aperto * (**) free field * (**) med db(a) 42 (52) 46 (56) min db(a) 38 (48) 43 (53) Dimensioni e pesi Weight and dimensions Dimensioni Dimensions LxHxP mm 930x298x x298x200 Peso Weight kg Attacchi ingresso e uscita acqua Inlet and outlet connections Øe 12 rame/copper (1) Dati riferiti alle seguenti condizioni: acqua 7/12 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. (*) Pressione sonora rilevata in ambiente di 100 m 3, a 1,5 m di distanza e tempo di riverbero 0,3 s. (**) Potenza Sonora in accordo alla normative Eurovent 8/2. Nota: L acqua che circola nello scambiatore non deve superare i 60 C. (1) Data referred to the following conditions: water 7/12 C and inlet air temperature 27 C d.b. / 19 C w.b.. (2) Data referred to the following conditions: inlet water 50 C and inlet air temperature 20 C d.b. / 15 C w.b. (*) Sound pressure level, in a 100 m 3 room, 1.5 m distance and reverberating time of 0.3 s. (**) Sound Power in accordance with regulations Eurovent 8/2. Note: The water circulating in the exchanger must not exceed 60 C. L P H

40 Ventilconvettori / Fan coils Ventilconvettore a cassette ad acqua Water cassette fan coil SILENCE AEWC AEWC AEWC 32 Codice Code Prezzo Price Euro Modello Model super (2) kw Capacità di riscaldamento (a velocità) Heating capacity (to speed) max (2) kw med (2) kw min (2) kw Portata d acqua (a velocità ) Water flow (to speed) super (2) l/h Perdita di carico (a velocità) Water pressure drop (to speed) super (2) kpa super (3) kw Capacità di riscaldamento (a velocità) Heating capacity (to speed) max (3) kw med (3) kw min (3) kw Portata d acqua (a velocità ) Water flow (to speed) super (3) l/h Perdita di carico (a velocità ) Water pressure (to speed) super (3) kpa super (1) Total kw Sensible kw Capacità di raffreddamento (a velocità) Cooling capacity (to speed ) max (1) Total kw Sensible kw med (1) Total kw Sensible kw min (1) Total kw Sensible kw Portata d acqua (a velocità ) Water flow (to speed) super (1) l/h Perdita di carico (a velocità ) Water pressure (to speed) super (1) kpa super m 3 /h Portata d aria Air flow max m 3 /h med m 3 /h min m 3 /h Tensione alimentazione Power supply V/Ph/Hz Potenza assorbita Total power absorbed kw Corrente assorbita Total current A super db(a) Livello di pressione sonora ad 1 m di distanza Noise pressure level at 1 m distance max db(a) campo aperto free field med db(a) min db(a) Dimensioni e pesi Weight and dimensions Dimensioni Unità Dimensions unit LxHxP Peso Unità Weight unit kg Dimensioni Pannello Dimensions Panel LxHxP Peso Pannello Weight Panel kg Attacchi ingresso e uscita acqua Inlet and outlet connections Ø L e P L e P H H AEWC AEWC 32

41 È previsto che ogni unità AEWC venga dotata del Kit Valvola motorizzata Is provided that every AEWC unit have equipped the Motorized valve kit Codice / Code Euro ,80 Per il modello AEWC 32 è necessario ordinare anche n.2 riduzioni 1 x 3/4 For the AEWC 32 model it is necessary to order two 1 x 3/4 reductions Codice / Code Euro ,84 FORNITI DI SERIE STANDARD SUPPLIED , , , ,00 AEWC 13 AEWC 18 AEWC 24 AEWC 32 8,21 10,22 12,2 17,83 5,49 7,7 8,24 15,87 4,4 5,78 5,77 11,09 3,57 4,62 4,55 8, ,76 5,98 7,12 9,95 3,12 4,93 5,16 9,07 2,61 3,69 3,86 6,79 1,95 2,7 3,09 5, ,46 4,49 5,33 8,80 2,91 3,75 4,56 6,34 2,62 3,50 4,62 7,32 2,21 2,90 3,94 5,11 1,67 2,84 4,17 6,57 1,54 2,33 3,55 4,50 1,49 1,69 3,21 5,80 1,33 1,55 2,73 3, ,6 11,8 15, /1/50 230/1/50 230/1/50 230/1/50 0,100 0,110 0,155 0,205 0,4 0,5 0,7 0, x310x x310x x310x x314x ,5 720x40x x40x x40x x55x950 2,5 2,5 2,5 4 3/4 3/4 3/4 1 I dati sono riferiti alle seguenti condizioni di prova: (1) Temperatura aria in ingresso 27 C b.s./19 C b.u. / Temperatura acqua in ingresso 7 C Temperatura acqua in uscità 12 C (2) Temperatura aria in ingresso 20 C b.s./15 C b.u. / Temperatura acqua in ingresso 70 C Temperatura acqua in uscità 60 C (3) Temperatura aria in ingresso 20 C b.s./15 C b.u. / Temperatura acqua in ingresso 50 C Portata acqua come condizioni di prova (1) Nota: Limiti di funzionamento temperatura acqua da +2 C a +70 C. Data refer to the following test conditions: (1) Inlet temperature air 27 C d.b./19 C w.b. / Inlet water temperature 7 C Outlet water temperature 12 C (2) Inlet temperature air 20 C d.b./15 C w.b. / Inlet water temperature 70 C Outlet water temperature 60 C (3) Inlet temperature air 20 C d.b./15 C w.b. / Inlet water temperature 50 C Water flow same as condition (1) Note: Water temperature operating range from +2 C to +70 C.

42 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM ETI - DC INVERTER Premessa I vari sistemi di raffrescamenro, deumidificazione e riscaldamento oggi trovano, una valida ed innovativa risposta, con l utilizzo di un solo apparecchio Silence THIN in grado di creare e mantenere, le condizioni di benessere in tutte le stagioni, grazie ad un controllo sofisticato e preciso. THIN è provvisto della nuovissima tecnologia DC INVERTER con motore a magneti permanenti ad alta efficienza, regolato in potenza e velocità mediante un dispositivo elettronico in modulazione di impulsi PWM (pulse with modulation), che permette una significativa riduzione delle vibrazioni, rumorosità e riduzione dei consumi dal 30 al 50% rispetto ai tradizionali motori elettrici AC. La linea leggera ed armoniosa e la profondità ridotta (13 cm) lo rendono perfettamente adatto in qualsiasi tipologia di ambiente integrandosi come componente di arredo. Di facile e rapida installazione con : - attacchi idraulici standard a sinistra e su richiesta, a destra - valvola elettrica (on-off 230V) a tre vie, installata e collegata elettricamente nell unità La gamma è suddivisa nelle versioni con MOBILE DI COPERTURA e AD INCASSO, per installazione verticale a parete e orizzontale a soffitto, disponibile in diverse grandezze in base alla potenzialità richiesta e applicabile su impianti del tipo a due tubi, inoltre possono essere provvisti di vari accessori e tipologie di controlli. Introduction Today the various cooling, dehumidification and heating systems find a valid and innovative solution with the use of a single device, Silence THIN, which is able to create and maintain the conditions of total comfort thanks to its sophisticated and precise control. THIN is equipped with the new technology INVERTER DC permanent magnet motor with high efficiency, power and speed adjusted by means of an electronic device in pulse modulation PWM (pulse with modulation), which allows a significant reduction of vibration and noise reduction consumption by 30 to 50% compared to conventional AC electric motors. The delicate and balanced design and reduced depth (13 cm) make it perfectly suited for any type of environment, integrating as a furnishing component. The installation is quick and simple with: - standard hydraulic connections on the left (on the right upon request), - electric valve (on-off 230V) three-way, installed and electrically connected in the unit. The range is divided into versions with CABINET and BUILT-IN, for vertical installation on wall and ceiling horizontal, available in different sizes depending on the required capacity and applicable on plant-type two pipes, also can be equipped with accessories and various types of controls. Versioni con MOBILE DI COPERTURA Versions with COVER CABINET ETM a parete ETM wall-mounted ETM a soffitto ETM ceiling-mounted Versioni AD INCASSO BUILT-IN model ETI a parete ETI wall-mounted ETI a soffitto ETI ceiling-mounted

43 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE THIN ETM ETI - DC INVERTER Serie / Series ETM ETI 2 TUBI /PIPE 2 TUBI /PIPE Versioni con MOBILE DI COPERTURA (ETM) Tali modelli sono identificati dall acronimo ETM. In funzione del tipo di installazione e del tipo di comando a bordo o a parete sono disponibili le seguenti configurazioni. Modelli ETM...DB e ETM...SB (versione BASE ) Ventilconvettore per installazione a pavimento, provvisto di: selettore di velocità e ON/OFF a pulsante, termostato ambiente regolabile da 5 a 30 C, selettore estate/inverno e funzione minima temperatura invernale e sonda aria in aspirazione, e controlla la valvola a 3 vie di deviazione con motore elettrotermico a 2 punti (ON/OFF 230V~) normalmente chiusa. L installazione dei piedini di appoggio (accessori) è facoltativa in quanto il ventilconvettore può essere installato a parete ad almeno 80 mm dal pavimento. Versions with COVER CABINET (ETM) These models are identified by the ETM... acronym. The following configurations are available based on the type of installation and of on-board or wall-mounted control. ETM...DB and ETM...SB Models ( BASE version) Fan coil for floor installation, provided with: speed selector and ON/OFF button, 5 to 30 C adjustable room thermostat, summer/winter selector and minimum winter temperature function and suction air probe, and checks the normally closed 3-way deviation valve with 2-point electrothermal motor (ON/OFF 230V~). Installing support feet (accessories) is optional as the fan coil can be wall-mounted at least 80 mm from the floor. Modelli ETM...DT e ETM...ST (Terminal Block) Ventilconvettore per installazione a pavimento o orizzontale a soffitto, provvisto di : bacinelle di raccolta condensa sia orizzontale che verticale, morsettiera elettrica per la gestione delle velocità dell elettroventilatore e la valvola a 3 vie di deviazione con motore elettrotermico a 2 punti (ON/OFF 230V~) normalmente chiusa. Per la gestione di tali modelli, possono essere utilizzati dei termostati ambiente elettronici TAE o digitale TAD (da ordinare separatamente ). ETM...DT and ETM...ST Models (Terminal Block) Fan coil for floor installation or horizontal ceiling, provided with: horizontal and vertical condensation collection trays, electric terminal block for managing the electric fan speed and the normally closed 3-way diverter valve with 2-point electric terminal motor (ON/OFF 230V~). TAE electronic room thermostats or TAD digital ones (to be ordered separately), can be used to manage these models. Termostato ambiente TAE (optional) TAE Electronic control panel (optional) Termostato ambiente digitale TAD (optional) TAD Digital control panel (optional)

44 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM ETI - DC INVERTER Modelli ETM...DE e ETM...SE (versione EVOLUTA ) Ventilconvettore per installazione a pavimento, provvisto di: un termoregolatore elettronico a Bordo macchina per una gestione remota tramite il comando a parete Broadcast CRB-DC (accessorio obbligatorio). Il termoregolatore controlla la valvola a 3 vie di deviazione con motore elettrotermico a 2 punti (ON / OFF 230V~) normalmente chiusa e dispone di un LED che indica lo stato di funzionamento ed eventuali anomalie, ed un tasto per l isolamento temporaneo dalla rete. Deve essere sempre collegato al controllo CRB-DC, i principali parametri operativi, il set point, e la temperatura ambiente, vengono trasmessi dal comando remoto CRB-DC. Ad un solo comando CRB-DC possono essere collegati fino a 30 termoregolatori. L applicazione più comune è quella del grande ambiente dove da un solo termostato CRB-DC si possono controllare più terminali collegati elettricamente tra loro. Per l eventuale installazione del ventilconvettore a soffitto, se funzionante in modalità raffreddante, è necessario applicare l apposita bacinella di raccolta condensa BRC (accessorio). ETM...DE and ETM...SE Models ( EVOLUTA version) Fan coil for floor installation, provided with: on board machine electronic thermoregulator for remote management through the CRB-DC Broadcast (compulsory accessory) wall-mounted control. the thermoregulator checks the 3-way diversion valve with normally closed 2-points electrothermal motor (ON/OFF 230V~) and has a LED to indicate the operating state and any anomalies, and a key for the mains network insulation. It must always be connected to the CRB-DC control. The main operating parameters, the set point and the room temperature are transmitted by the CRB-DC remote control. Up to 30 thermoregulators can be connected to a single CRB-DC control. The large room is the most common application where more terminals electrically connected between them, can be controlled by a single CRB-DC thermostat. The specific BRC condensation collection tray (accessory) must be applied for fan coil ceiling installation, if working in cooling mode. ETM 2xx SB Versione Base Basic version Comando remoto CRB-DC (accessorio obbligatorio) CRB-DC remote control (compulsory accessory) Versioni AD INCASSO (ETI) Modelli senza mobile di copertura per installazione ad incasso verticale o orizzontale a soffitto, il ventilconvettore è predisposto per le due tipologie di installazione in quanto dotato di bacinelle di raccolta condensa sia orizzontale che verticale; sono adatti per tutte quelle applicazioni in cui è richiesto il posizionamento ad incasso in nicchie o controsoffitti e sono supportati da una vasta gamma di accessori. Anche per questi modelli si possono scegliere varie tipologie di controlli. Tali modelli sono identificati dall acronimo ETI. In funzione del tipo di installazione e del tipo di comando a bordo o a parete sono disponibili le seguenti configurazioni. Modelli ETI...DT e ETI...ST (Terminal Block) Ventilconvettore per installazione a pavimento o orizzontale a soffitto, provvisto di : bacinelle di raccolta condensa sia orizzontale che verticale, morsettiera elettrica per la gestione delle velocità dell elettroventilatore e la valvola a 3 vie di deviazione con motore elettrotermico a 2 punti (ON/OFF 230V~) normalmente chiusa. Per la gestione di tali modelli, possono essere utilizzati dei termostati ambiente elettronici TAE o digitale TAD (da ordinare separatamente). BUILT-IN versions (ETI) The fan coil is set-up for two kinds of installations as it is equipped with horizontal and vertical condensation collection tray in models without cover cabinet for ceiling vertical or horizontal built-in installation; suitable for all applications with built-in positioning in niches or false-ceilings and are supported by a wide range of accessories. Different controls can be chosen for these models also. These models are identified by the ETI... acronym. The following configurations are available based on the type of installation and of on-board or wall-mounted control. ETI...DT and ETI...ST Models (Terminal Block) Fan coil for floor installation or horizontal ceiling, provided with: horizontal and vertical condensation collection trays, electric terminal block for managing the electric fan speed and the normally closed 3-way diverter valve with 2-point electric terminal motor (ON/OFF 230V~). TAE electronic room thermostats or TAD digital ones (to be ordered separately), can be used to manage these models.

45 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE THIN ETM ETI - DC INVERTER Modelli ETI...DE e ETI...SE versione Evoluta Ventilconvettore per installazione a pavimento o orizzontale a soffitto, provvisto di: un termoregolatore elettronico a Bordo macchina per una gestione remota tramite il comando a parete Broadcast CRB-DC (accessorio obbligatorio). Il termoregolatore controlla la valvola a 3 vie di deviazione con motore elettrotermico a 2 punti ( ON / OFF 230V~) normalmente chiusa e dispone di un LED che indica lo stato di funzionamento ed eventuali anomalie, ed un tasto per l isolamento temporaneo dalla rete. Deve essere sempre collegato al controllo CRB-DC, i principali parametri operativi, il set point, e la temperatura ambiente, vengono trasmessi dal comando remoto CRB-DC. Ad un solo comando CRB-DC possono essere collegati fino a 30 termoregolatori. L applicazione più comune è quella del grande ambiente dove da un solo termostato CRB-DC si possono controllare più terminali collegati elettricamente tra loro. Evoluta version ETI...DE e ETI...SE Models Fan coil for floor installation or horizontal ceiling, provided with: on board machine electronic thermoregulator for remote management through the CRB-DC Broadcast (compulsory accessory) wall-mounted control. the thermoregulator checks the 3-way diversion valve with normally closed 2-points electrothermal motor (ON/OFF 230V~) and has a LED to indicate the operating state and any anomalies, and a key for the mains network insulation. It must always be connected to the CRB-DC control. The main operating parameters, the set point and the room temperature are transmitted by the CRB-DC remote control. Up to 30 thermoregulators can be connected to a single CRB-DC control. The large room is the most common application where more terminals electrically connected between them, can be controlled by a single CRB-DC thermostat. Parte idraulica comune a tutti i ventilconvettori Il gruppo valvola a 3 vie di deviazione con motore elettrotermico è formato da una valvola a 3 vie con by pass di deviazione calibrato, il detentore idraulico, il raccordo di uscita ed un tubo flessibile per il collegamento del by pass e da coppelle isolanti preformate per corpo valvola e detentore. La testina elettrotermica a 2 punti ( ON / OFF 230V~) è normalmente chiusa. La parte idraulica è già assemblata e montata allo scambiatore di calore. Hydraulic part common to all the fan-coil convectors The 3-way diverter valve group with electrothermal motor is composed of a 3-way valve with calibrated diversion by-pass, hydraulic shut-off valve, outlet fitting and a hose for connection of the by-pass and some preformed insulating covers for the shut-off valve and valve body. The 2-point electrothermal head (ON / OFF 230V~) is normally closed. The hydraulic part is already assembled and mounted on the heat exchanger. Identificazione modello Identification code Colonna Column ET M 2 20 S B Colonna 1 ET = Emmeti Silence Thin Colonna 2 M = Modello con mobile I = Modello da incasso Colonna 3 2 = una sola batteria (impianti a due tubi) Colonna 4 20 = oppure (indica la taglia) Colonna 5 S = Attacchi idraulici a sinistra D = Attacchi idraulici a destra Colonna 6 B = Versione BASE E = Versione EVOLUTA T = Versione TERMINAL BLOCK Column 1 ET = Emmeti Silence Thin Column 2 M = Model with cabinet I = Built-in model Column 3 2 = One coil only (two-pipe systems) Column 4 20 = Or (indicates the size) Column 5 S = Hydraulic connections on the left D = Hydraulic connections on the right Column 6 B = BASE model E = EVOLUTA model T = TERMINAL BLOCK model

46 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM - DC INVERTER Dati tecnici modello verticale a pavimento e orizzontale a soffitto Technical data vertical floor-mounted and horizontal ceiling-mounted version Modelli ETM Models ETM Potenzialità termica (1) Heating capacity (1) kw (max) 1,89 3,99 5,47 6,98 Portata d acqua (1) Water flow (1) l/h Perdite di carico (1) Loss of charge (1) kpa 6,7 7,6 16,1 14,0 Potenzialità termica (1) * Heating capacity (1) * kw (max) 0,322 0,379 0,447 0,563 Potenzialità termica (2) Heating capacity (1) kw (max) 1,09 2,35 3,19 4,10 Portata d acqua (2) Water flow (2) l/h Perdite di carico (2) Loss of charge (2) kpa 5,7 6,6 16,3 14,0 Pot. frigorifera totale (3) Refrigerating capacity (3) kw (max) 0,83 1,76 2,65 3,34 Pot. frigorifera sensibile (3) Refrigerating cap. sensible (3) kw (max) 0,62 1,27 1,96 2,65 Portata d acqua (3) Water flow (3) l/h Perdite di carico (3) Loss of charge (3) kpa 7,2 8,4 22,5 18,6 Portata aria (6) Air flow (6) m 3 /h (max) m 3 /h (med) m 3 /h (min) Pressione statica max utile Loss of charge Pa Pressione sonora (4) Sound pressure (4) db(a) (max) 39,4 40,2 42,2 42,5 db(a) (med) 33,2 34,1 34,4 35 db(a) (min) 24,2 25,3 25,6 26,3 Numero ventilatori Fan number n Potenza max. motore Max power input fan motor W 11,9 17,6 19,8 26,5 Corrente max assorbita Max current absorbed A 0,11 0,16 0,18 0,26 Alimentazione Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 Attacchi idraulici (5) Connection (5) Ø 3/4 Eurocono / Eurokonus Contenuto acqua batteria Water quantity coil l 0,47 0,80 1,13 1,46 Pressione max di esercizio Maximum operating pressure bar Attacco scarico condensa Connection dry tube Ø Dimensioni e pesi Weight and dimensions Dimensioni Dimension LxHxPxA mm 735x579x131x x579x131x x579x131x x579x131x1105 Peso netto Weight net kg (1) Riscaldamento: Temperatura aria ambiente 20 C - Temperatura acqua ingresso 70 C Dt acqua 10 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (2) Riscaldamento: Temperatura aria ambiente 20 C - Temperatura acqua ingresso 50 C Portata acqua come in raffreddamento - massima velocità del ventilatore (Norma UNI EN 1397) (3) Raffreddamento: Temperatura aria ambiente 27 C b.s., 19 C b.u. - Temperatura acqua ingresso 7 C Dt acqua 5 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (Norma UNI EN 1397) (4) Pressione sonora: Misurata in camera semianecoica (ISO 7779) (5) Attacchi batteria di serie a sinistra (6) Portata aria con filtri puliti. * Valori riferiti alle condizioni (1) ma con ventilatore spento (70 C). Nota: Attacchi idraulici standard a sinistra guardando frontalmente il ventilconvettore e il controllo si trova nella parte opposta agli attacchi Attacchi dalla parete / Connections from wall L A P (1) Heating: Room air temperature 20 C - Water inlet temperature 70 C Water Dt 10 C maximum speed for medium and low speed, water flow rate remains same as at maximum speed (2) Heating: Room air temperature 20 C - Water inlet temperature 50 C Water flow rate same as in cooling operation - maximum speed (UNII EN 1397) (3) Cooling: Room air temperature 27 C d.b., 19 C w.b. - Water inlet temperature 7 C Water Dt 5 C maximum speed for medium and low speed, water flow rate remains same as at maximum speed (UNI EN 1397) (4) Sound pressure: Measured in semianechoic room (ISO 779) (5) Connection exchange left standard (6) Air flow rate with clean filters. * Values referred to the conditions (1) but with the fan off (70 C). Note: If fan coil is watched frontally, standard plumbing fittings will be to the left and the control is placed in the opposite side of the fittings Attacchi dal pavimento Connections from floor H

47 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE THIN ETI - DC INVERTER Dati tecnici modello incasso verticale a pavimento e orizzontale a soffitto Technical data vertical floor-mounted and horizontal ceiling-mounted built-in version Modelli ETI Models ETI Potenzialità termica (1) Heating capacity (1) kw (max) 1,89 3,99 5,47 Portata d acqua (1) Water flow (1) l/h Perdite di carico (1) Loss of charge (1) kpa 6,7 7,6 16,1 Potenzialità termica (1) * Heating capacity (1) * kw (max) 0,322 0,379 0,447 Potenzialità termica (2) Heating capacity (1) kw (max) 1,09 2,35 3,19 Portata d acqua (2) Water flow (2) l/h Perdite di carico (2) Loss of charge (2) kpa 5,7 6,6 16,3 Pot. frigorifera totale (3) Refrigerating capacity (3) kw (max) 0,83 1,76 2,65 Pot. frigorifera sensibile (3) Refrigerating cap. sensible (3) kw (max) 0,62 1,27 1,96 Portata d acqua (3) Water flow (3) l/h Perdite di carico (3) Loss of charge (3) kpa 7,2 8,4 22,5 Portata aria Air flow m 3 /h (max) m 3 /h (med) m 3 /h (min) Pressione statica max utile Loss of charge Pa Pressione sonora (4) Sound pressure (4) db(a) (max) 39,4 40,2 42,2 db(a) (med) 33,2 34,1 34,4 db(a) (min) 24,2 25,3 25,6 Numero ventilatori Fan number n Potenza max. motore Max power input fan motor W 11,9 17,6 19,8 Corrente max assorbita Max current absorbed A 0,11 0,16 0,18 Alimentazione Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 Attacchi idraulici (5) Connection (5) Ø 3/4 Eurocono / Eurokonus Contenuto acqua batteria Water quantity coil l 0,47 0,80 1,13 Pressione max di esercizio Maximum operating pressure bar Attacco scarico condensa Connection dry tube Ø Dimensioni e pesi Weight and dimensions Dimensioni Dimension LxHxP mm 525x576x x576x x576x126 Peso netto Weight net kg (1) Riscaldamento: Temperatura aria ambiente 20 C - Temperatura acqua ingresso 70 C Dt acqua 10 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (2) Riscaldamento: Temperatura aria ambiente 20 C - Temperatura acqua ingresso 50 C Portata acqua come in raffreddamento - massima velocità del ventilatore (Norma UNI EN 1397) (3) Raffreddamento: Temperatura aria ambiente 27 C b.s., 19 C b.u. - Temperatura acqua ingresso 7 C Dt acqua 5 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (Norma UNI EN 1397) (4) Pressione sonora: Misurata in camera semianecoica (ISO 7779) (5) Attacchi batteria di serie a sinistra (6) Portata aria con filtri puliti. * Valori riferiti alle condizioni (1) ma con ventilatore spento (70 C). (1) Heating: Room air temperature 20 C - Water inlet temperature 70 C Water Dt 10 C maximum speed for medium and low speed, water flow rate remains same as at maximum speed (2) Heating: Room air temperature 20 C - Water inlet temperature 50 C Water flow rate same as in cooling operation - maximum speed (UNII EN 1397) (3) Cooling: Room air temperature 27 C d.b., 19 C w.b. - Water inlet temperature 7 C Water Dt 5 C maximum speed for medium and low speed, water flow rate remains same as at maximum speed (UNI EN 1397) (4) Sound pressure: Measured in semianechoic room (ISO 779) (5) Connection exchange left standard (6) Air flow rate with clean filters. * Values referred to the conditions (1) but with the fan off (70 C). L P H

48 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM - DC INVERTER Modelli con mobile di copertura per diverse tipologie di installazione. Connessioni idrauliche a destra o a sinistra con valvola a 3 vie e detentore. Models with cover cabinet for some type of installation. Hydraulic connections on the right or on the left with 3-way valve and shut-off valve. NOTA: - I piedini CP1 sono optional. - Per l installazione orizzontale a soffitto è necessario l accessorio BRC. Non serve per i modelli ETM 2xx DT e ETM 2xx ST NOTE: - The CP1 feets are optional. - The BRC accessory is required for horizontal ceiling-mounted installation. It s not necessary for the ETM 2xx DT and ETM 2xx ST models. VERSIONE / VERSION BASE Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale a parete e pavimento - 1 batteria (impianto a 2 tubi) Vertical fan-coil wall and floor - 1 coil (2 pipe system) ETM 220 DB (attacchi dx / connection right) 0,83 1, ,02 ETM 240 DB (attacchi dx / connection right) 1,76 2, ,01 ETM 260 DB (attacchi dx / connection right) 2,65 3, ,10 ETM 280 DB (attacchi dx / connection right) 3,34 4, ,74 ETM 220 SB (attacchi sx / connection left) 0,83 1, ,02 ETM 240 SB (attacchi sx / connection left) 1,76 2, ,01 ETM 260 SB (attacchi sx / connection left) 2,65 3, ,10 ETM 280 SB (attacchi sx / connection left) 3,34 4, ,74 Modelli a richiesta / Models on request (1) Dati riferiti alle seguenti condizioni: acqua 7/1 2 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: water 7/12 C and inlet temperature air 27 C d.b. / 19 C w.b. ( UNI EN 1397 ) (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b. ( UNI EN 1397 )

49 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE THIN ETM - DC INVERTER VERSIONE / VERSION TERMINAL BLOCK Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale a parete/pavimento e orizzontale a soffitto - 1 batteria (impianto a 2 tubi) Vertical fan-coil wall/floor and horizontal ceiling version - 1 coil (2 pipe system) ETM 220 DT (attacchi dx / connection right) 0,83 1, ,82 ETM 240 DT (attacchi dx / connection right) 1,76 2, ,56 ETM 260 DT (attacchi dx / connection right) 2,65 3, ,21 ETM 280 DT (attacchi dx / connection right) 3,34 4, ,72 ETM 220 ST (attacchi sx / connection left) 0,83 1, ,82 ETM 240 ST (attacchi sx / connection left) 1,76 2, ,56 ETM 260 ST (attacchi sx / connection left) 2,65 3, ,21 ETM 280 ST (attacchi sx / connection left) 3,34 4, ,72 Modelli a richiesta / Models on request VERSIONE / VERSION EVOLUTA Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale a parete e pavimento - 1 batteria (impianto a 2 tubi) Vertical fan-coil wall and floor - 1 coil (2 pipe system) ETM 220 DE (attacchi dx / connection right) 0,83 1, ,45 ETM 240 DE (attacchi dx / connection right) 1,76 2, ,44 ETM 260 DE (attacchi dx / connection right) 2,65 3, ,53 ETM 280 DE (attacchi dx / connection right) 3,34 4, ,14 ETM 220 SE (attacchi sx / connection left) 0,83 1, ,45 ETM 240 SE (attacchi sx / connection left) 1,76 2, ,44 ETM 260 SE (attacchi sx / connection left) 2,65 3, ,53 ETM 280 SE (attacchi sx / connection left) 3,34 4, ,14 Per l eventuale installazione del ventilconvettore a soffitto, se funzionante in modalità raffreddante, è necessario applicare l apposita bacinella di raccolta condensa BRC (accessorio) / The specific BRC condensation collection tray (accessory) must be applied for fan coil ceiling installation, if working in cooling mode. Modelli a richiesta / Models on request (1) Dati riferiti alle seguenti condizioni: acqua 7/1 2 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: water 7/12 C and inlet temperature air 27 C d.b. / 19 C w.b. ( UNI EN 1397 ) (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b. ( UNI EN 1397 )

50 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETI - DC INVERTER Modelli senza mobile di copertura per installazione a parete verticale e orizzontale a soffitto. Connessioni idrauliche a destra o a sinistra con valvola a 3 vie e detentore. Models without cover cabinet for vertical wall-mounted and horizontal ceiling-mounted installation. Hydraulic connections on the right or on the left with 3-way valve and shut-off valve. VERSIONE / VERSION TERMINAL BLOCK Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) 1 batteria (impianto a 2 tubi) / 1 coil (2 pipe system) ETI 220 DT (attacchi dx / connection right) 0,83 1, ,57 ETI 240 DT (attacchi dx / connection right) 1,76 2, ,78 ETI 260 DT (attacchi dx / connection right) 2,65 3, ,97 ETI 220 ST (attacchi sx / connection left) 0,83 1, ,57 ETI 240 ST (attacchi sx / connection left) 1,76 2, ,78 ETI 260 ST (attacchi sx / connection left) 2,65 3, ,97 VERSIONE / VERSION EVOLUTA Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) 1 batteria (impianto a 2 tubi) / 1 coil (2 pipe system) ETI 220 DE (attacchi dx / connection right) 0,83 1, ,73 ETI 240 DE (attacchi dx / connection right) 1,76 2, ,94 ETI 260 DE (attacchi dx / connection right) 2,65 3, ,13 ETI 220 SE (attacchi sx / connection left) 0,83 1, ,73 ETI 240 SE (attacchi sx / connection left) 1,76 2, ,94 ETI 260 SE (attacchi sx / connection left) 2,65 3, ,13 (1) Dati riferiti alle seguenti condizioni: acqua 7/1 2 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: water 7/12 C and inlet temperature air 27 C d.b. / 19 C w.b. ( UNI EN 1397 ) (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. ( UNI EN 1397 ) Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b. ( UNI EN 1397 ) Modelli a richiesta (disponibilità circa 15 giorni dalla conferma dell ordine) Models on request (available in about 15 days from the order confirmation)

51 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua Air cooled liquid chillers and heat pumps SILENCE THIN ETM ETI - DC INVERTER CP1 Coppia piedini estetici per fissaggio a parete Pair of attractive feet for fastening to the wall Modello / Model Codice / Code Euro Consentono la mascheratura estetica delle tubazioni di collegamento idraulico provenienti dal pavimento. Vanno montati su apparecchi con fissaggio a parete. Non sono da utilizzare per fissaggio del ventilconvettore a pavimento. Colore Bianco RAL9010 These accessories cover the hydraulic pipes coming up through the floor. They should be fitted on appliances anchored to the back wall. These feet should not be used to anchor the terminal to the ground. White colour RAL ,31 PP1 Coppia piedini estetici per installazione a pavimento Pair of attractive feet for floor installation Modello / Model Codice / Code Euro Consentono il fissaggio a pavimento del ventilconvettore, quando non è possibile il fissaggio a parete. Consentono il passaggio delle tubazioni idrauliche se provenienti dal pavimento. Colore Bianco RAL9010 Pair of feet for anchoring the terminal to the ground in the event it cannot be fastened to the back wall. Also cover any hydraulic pipes coming up through the floor. White colour RAL ,62 CRB-DC Comando remoto a parete Broadcast Remote Control wall Broadcast Modello / Model Codice / Code Euro Comando remoto a parete da abbinare ai ventilconvettori ETM e/o ,94 ETI in versione evoluta DE o SE. Possibilità di controllo fino a 30 ventilconvettori. Sonda ambiente presente all interno del comando. Comunicazione di tipo BUS, su rete di lunghezza max 1 km. I cavi devono CRB-DC essere schermati. A corredo viene fornita una scheda alimentatore da 230/12 VDC per l alimentazione elettrica del controllo che va installata RS 485 nella scatola dei collegamenti presente a bordo di uno dei ventilatori 12 Vdc versione evoluta. Remote control fixed to the wall, to be matched to ETM and/or ETI fan coils in DE or SE advanced version. ET... 1 ET... 2 ET Possibility of controlling until 30 fan coils. Bus type Communication on the network of length 1 km max. The cables must be shielded. Fan coil is equipped with a power board of 230/12 VDC for the electric power supply of the control and has to be installed into the 230V~ connections box placed on board of one of the advanced version fans.

52 Ventilconvettori / Fan coils Accessori Accessories CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM ETI - DC INVERTER BRC Bacinella raccolta condensa per installazione orizzontale modelli ETM Condensation collection basin for ETM horizontal model installation Modello / Model Codice / Code Euro BRC20 bacinella raccolta condensa per installazione orizzontale a soffitto ,31 BRC20 condensation collection basin for horizontal ceiling-mounted installation BRC40 bacinella raccolta condensa per installazione orizzontale a soffitto BRC40 condensation collection basin for horizontal ceiling-mounted installation BRC60 bacinella raccolta condensa per installazione orizzontale a soffitto BRC60 condensation collection basin for horizontal ceiling-mounted installation BRC80 bacinella raccolta condensa per installazione orizzontale a soffitto BRC80 condensation collection basin for horizontal ceiling-mounted installation L accessorio è formato da una bacinella in ABS da fissare al ventilconvettore, nascosta dal mantello estetico. Insieme alla bacinella viene fornito il relativo isolante termico, e appositi tubi per scarico condensa e tappo bacinella. Ha inoltre le fascette di sicurezza per la griglia di aspirazione. The accessory is composed of an ABS basin to be fixed to the fan-coil convector, hidden by the attractive shell. The relative thermal insulation, appropriate condensation discharge tubes and basin plug are supplied together with the basin. It also has the safety clamps for the intake grille , , ,36 CF Cassaforma per installazione ad incasso con uscita aria frontale Box for built-in installation with front air output Modello / Model Codice / Code Euro CF20 per modello ETI 220 / CF20 for model ETI ,16 CF40 per modello ETI 240 / CF40 for model ETI ,67 CF60 per modello ETI 260 / CF60 for model ETI ,00 La cassaforma in lamiera zincata è predisposta per essere inserita in pareti o controsoffitti nella quale inserire il ventilconvettore. La cassaforma ha dei pretranci per passaggio cavi elettrici e tubazioni idrauliche. La cassaforma si accoppia al pannello estetico PE della stessa grandezza. This accessory is a galvanized sheet metal casing made to be inserted into the wall or false ceiling where the terminal is housed. It is pre-cut to allow for routing of hydraulic pipes and electric cables. The structure fits to the built-in cover panel PE. Modello / Model Lunghezza / Length 220 L = 715 mm 240 L = 915 mm 260 L = 1115 mm Modelli a richiesta (disponibilità circa 15 giorni dalla conferma dell ordine) Models on request (available in about 15 days from the order confirmation)

53 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua Air cooled liquid chillers and heat pumps SILENCE THIN ETM ETI - DC INVERTER PE Pannello estetico di copertura cassaforma Attractive box cover panel Modello / Model Codice / Code Euro PE20 per modello ETI 220 / PE20 for model ETI ,90 PE40 per modello ETI 240 / PE40 for model ETI ,00 PE60 per modello ETI 220 / PE60 for model ETI ,30 Il pannello estetico di colore bianco RAL9010, si accoppia alla cassaforma CF, della stessa grandezza. È formato da una cornice esterna, un pannello frontale, una griglia rimovibile per la pulizia del filtro aria, e da un deflettore regolabile manualmente per la mandata aria in ambiente. The panel is designed to fit perfectly to the built-in casing of the same size. The standard colour is RAL It includes: outer frame, front panel, removable grill for cleaning air filters and adjustable deflector for diverting ambient air flow. Modello / Model Lunghezza / Length 220 L = 772 mm 240 L = 972 mm 260 L = 1172 mm CT Canale telescopico mandata aria per installazione da incasso Telescopic air flow channel for built-in installation Modello / Model Codice / Code Euro CT20 per modello ETI 220 / CT20 for model ETI ,14 CT40 per modello ETI 240 / CT40 for model ETI ,16 CT60 per modello ETI 260 / CT60 for model ETI ,30 Il canale telescopico è realizzato in lamiera zincata, rivestita internamente con isolante per evitare fenomeni di rugiada, ed è regolabile in lunghezza da 302 a 590 mm. Our telescopic duct is adjustable in length to better adapt to installation requirements. It is made of galvanized sheet metal coated on the inside with insulating material to prevent condensation. Modello / Model Lunghezza / Length 220 L = 307,5 mm 240 L = 507,5 mm 260 L = 707,5 mm Modelli a richiesta (disponibilità circa 15 giorni dalla conferma dell ordine) Models on request (available in about 15 days from the order confirmation)

54 Ventilconvettori / Fan coils Accessori Accessories CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM ETI - DC INVERTER C90 Canale curvo mandata aria a 90 per installazione da incasso 90 elbow channel for built-in installation Modello / Model Codice / Code Euro C9020 per modello ETI 220 / C9020 for model ETI ,06 C9040 per modello ETI 240 / C9040 for model ETI ,06 C9060 per modello ETI 260 / C9060 for model ETI ,08 Il canale curvo a 90 per mandata aria, è realizzato in lamiera zincata, rivestita internamente con isolante per evitare fenomeni di rugiada. It is made of galvanized sheet metal coated on the inside with insulating material to prevent condensation. Modello / Model Lunghezza / Length 220 L = 307,5 mm 240 L = 507,5 mm 260 L = 707,5 mm RA Raccordo di aspirazione aria per installazione da incasso Air intake fitting for built-in installation Modello / Model Codice / Code Euro RA20 per modello ETI 220 / RA20 for model ETI ,58 RA40 per modello ETI 240 / RA40 for model ETI ,58 RA60 per modello ETI 260 / RA60 for model ETI ,08 Il raccordo per aspirazione aria, è realizzato in lamiera zincata e non è rivestito di materiale isolante. It is made of galvanized sheet metal and not coated on the inside with insulating material. Modello / Model Lunghezza / Length 220 L = 305 mm 240 L = 505 mm 260 L = 705 mm Modelli a richiesta (disponibilità circa 15 giorni dalla conferma dell ordine) Models on request (available in about 15 days from the order confirmation)

55 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua Air cooled liquid chillers and heat pumps SILENCE THIN ETM ETI - DC INVERTER GA Griglia di aspirazione aria per installazione da incasso Air intake grille for built-in installation Modello / Model Codice / Code Euro GA20 per modello ETI 220 / GA20 for model ETI ,65 GA40 per modello ETI 240 / GA40 for model ETI ,80 GA60 per modello ETI 260 / GA60 for model ETI ,00 La griglia di aspirazione aria con profilo diritto è realizzata in alluminio. Per il fissaggio della griglia sono presenti dei fori sulla cornice che contorna la griglia. La griglia si accoppia ai raccordi di aspirazione per ventilconvettori ad incasso. An aluminium intake grill with a linear profile that fits perfectly to our air intake fittings for the built-in installation. The aluminum frame surrounding the grill has a series of holes for fastening to the intake fitting PASSO Ø8 TUBO DI FISSAGGIO ALETTE Lunghezza Length Altezza Height Profondità Depth L = 334 mm H = 150 mm P = 30 mm L = 534 mm H = 150 mm P = 30 mm L = 734 mm H = 150 mm P = 30 mm BM Bocchetta di mandata aria per installazione da incasso Air flow inlet for built-in installation Modello / Model Codice / Code Euro BM20 per modello ETI 220 / BM20 for model ETI ,50 BM40 per modello ETI 240 / BM40 for model ETI ,80 BM60 per modello ETI 260 / BM60 for model ETI ,80 La bocchetta di mandata aria con profilo diritto è realizzata in alluminio. La bocchetta ha un doppio filare di alette per regolazione verticale ed orizzontale del flusso d aria. Per il fissaggio della bocchetta sono presenti dei fori sulla cornice. La bocchetta si accoppia al canale telescopico CT e canale curvo 90 C90. The accessory comprises an aluminum vent with two rows of fins for horizontal and vertical adjustment of the air flow. The dimensions and holes on the frame fit perfectly to the accessories: telescopic duct and 90 duct model CT. 67 PASSO Lunghezza Length Altezza Height Profondità Depth L = 334 mm H = 128 mm P = 45 mm L = 534 mm H = 128 mm P = 45 mm L = 734 mm H = 128 mm P = 45 mm Modelli a richiesta (disponibilità circa 15 giorni dalla conferma dell ordine) Models on request (available in about 15 days from the order confirmation)

56 Ventilconvettori / Fan coils Accessori Accessories CLIMATIZZATORE Wall mounted air conditioners SILENCE THIN ETM ETI - DC INVERTER CCM-DC Cavo di collegamento motore (nel caso di rotazione attacchi idraulici da sinistra a destra) Motor connection cable kit for right-hand connection Modello / Model Codice / Code Euro CCM-DC per tutti i modelli ETI e ETM / for all models ETI and ETM ,37 Nel caso di rotazione attacchi idraulici da sinistra a destra è necessario utilizzare l apposito cablaggio per la connessione del motore. In the case of rotation of the water connections from left to right you must use the special cable to connect the engine. ADATT 3-4 Kit coppia adattatori 3/4 Eurocono - Battuta piana 3/4 Eurokonus adapter pair kit - Flat seal Modello / Model Codice / Code Euro ADATT 3-4 per tutti i modelli ETI e ETM / for all models ETI and ETM ,53 Permette la trasformazione degli attacchi 3/4 Eurocono in normali raccordi con filetto gas 3/4 M. A couple of insert for flat seal: for adapting the ¾ Eurokonus fitting to a ¾ M gas flat seal. DIST 3-4 Kit distanziale 3/4 Eurocono per installazione con attacchi idraulici a muro 3/4 Eurokonus spacer kit for installation with wall-mounted hydraulic connections Modello / Model Codice / Code Euro DIST 3-4 per tutti i modelli ETI e ETM / for all models ETI and ETM ,56 Nella versione con attacchi idraulici a muro (tubazioni idrauliche provenienti dal lato dello schienale del ventilconvettore) è necessario utilizzare il tronchetto distanziatore 3/4 Eurocono. In the version with the water connections to the wall (hydraulic hoses from the back side of the fan-coil ) you must use the socket spacer 3/4 Eurokonus.

57 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE MV MO IV IVO IVP IVPD SCHEDA TECNICA 40C Technical sheet 40C Premessa I vari sistemi di raffrescamento e di riscaldamento trovano oggi una valida risposta con l utilizzo dei ventilconvettori. Un estetica sempre più gradevole, un basso livello di rumorosità ed un sistema di controllo sempre più accurato, consentono l inserimento di questi prodotti in qualsiasi tipologia d ambiente grazie alla completezza della gamma offerta. Introduction The various cooling and heating systems which are available today find their needs met through the use of fan coil units. An ever more pleasing appearance, low noise levels and an ever more precise control system make it possible to place these products in any type of setting thanks to the completeness of the range which is offered. Versioni VERTICALI a parete e pavimento VERTICAL wall and floor model MV-AI MV-AF Versioni VERTICALI a parete e pavimento da incasso VERTICAL wall and floor built-in model IV-MF IVO-AP IVO-AF Versioni VERTICALI con pannello piano da incasso VERTICAL with cover panel built-in model IVP-AFMF

58 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE MV MO IV IVO IVP IVPD Versioni VERTICALI con pannello frontale e canale di mandata Vertical built-in versions with front panel and outlet duct Versioni ORIZZONTALI a soffitto HORIZONTAL ceiling model MO-AP MO-AI IVPD-AFMF Versioni ORIZZONTALI da incasso HORIZONTAL built-in model IVO-AF IVO-AP

59 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE MV MO IV IVO IVP IVPD Tabella riepilogativa di identificazione modelli Model identification chart Serie / Series MV-AI 2 TUBI PIPE MV-AF 2 TUBI PIPE MO-AP 2 TUBI PIPE MO-AI 2 TUBI PIPE IVO-AP 2 TUBI PIPE IVO-AF 2 TUBI PIPE IV-MF 2 TUBI PIPE IVP-AFMF 2 TUBI PIPE IVPD-AFMF 2 TUBI PIPE

60 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE MV MO IV IVO IVP IVPD ELENCO ACCESSORI PER VENTILCONVETTORI SILENCE (forniti separatamente) ACCESSORIES LIST FOR SILENCE FAN COILS (supplied separately) Pannello comando a bordo macchina con selettore 3 velocità + selettore OFF - Estate - Inverno; varie possibilità di collegamento On-board control panel with 3-speed selector + OFF selector - Summer - Winter; various connecting possibilities Pannello comando a bordo macchina elettronico con Termostato ambiente + selettore 3 velocità + selettore OFF - Estate - Inverno; Comanda valvole; varie possibilità di collegamento On-board electronic control panel with room thermostat + 3-speed selector + OFF selector - Summer - Winter; Controls valves 0-1-2; various connecting possibilities Pannello comando a bordo macchina elettronico a microprocessore con Termostato ambiente + selettore 3 velocità e Auto + selettore OFF - Estate - Inverno, con funzione antistratificazione; Comanda valvole; varie possibilità di collegamento On-board microprocessor electronic control panel with room thermostat + 3-speed and Auto selector + OFF selector - Summer - Winter, with anti-stratification fuction; Controls valves 0-1-2; various connecting possibilities Pannello comando a bordo macchina elettronico a microprocessore Digitale Configurabile con selettore 3 velocità + Auto, selettore Estate / inverno, on/off, visualizzazione temperatura ambiente, funzione economy, funzione antistratificazione, avviso filtro sporco, pilotaggio valvole On-board electronic control panel with digital settable microprocessor with 3-speed + Auto selector- Summer / Winter selector, on/off, room temperature display, economy function, anti-stratification function, dirty filter notification, valve control Termostato ambiente elettronico per ventilconvettori - Selettore 3 velocità, estate / off / inverno, manopola regolazione temperatura ambiente, pilotaggio valvole on/off (versione per montaggio a parete) Electronic control panel for fan coils - 3 speeds switch + summer / off / winter switch + temperature thermostat, driver for on/off valves (wall mounted version) Termostato ambiente digitale, configurabile per ventilconvettori - Selettore 3 velocità + auto, estate / inverno, on/off, visualizzazione temperatura ambiente, funzione economy, avviso filtro sporco, pilotaggio valvole (versione per montaggio a parete) Digital configurable control panel for fan coils - 3 speeds + auto switch, summer / winter, on/off, room temperature display, economy function, filter signal, driver for valves (wall mounted version) Termostato minima temperatura acqua / Water low temperature thermostat Sonda temperatura acqua con cavo da 1mt compatibile con comando 3TADEI Water temperature sensor with 1m cable compatible with 3TADEI control Kit di una Valvola a 3 vie, attacchi da 3/4 completa di servocomando elettrotermico ON/OFF con raccordi in rame per impianto 2 tubi Kit 3 ways electrovalve 230V ON/OFF with electrothermic actuator for standad coils Kit di una valvola a 3 vie, attacchi da 1/2 completa di servocomando elettronico ON/OFF e raccordi in rame per batteria aggiuntiva Kit 3 ways electrovalve 230V ON/OFF with electrothermic actuator for additional coils Bacinella ausiliaria tubazioni per tutte le versioni Verticali / Auxiliary drain pan for vertical version Bacinella ausiliaria tubazioni per tutte le versioni orizzontali con attacchi a sinistra Auxiliary drain pan for horizontal version with left water connections Bacinella ausiliaria tubazioni per tutte le versioni orizzontali con attacchi a destra Auxiliary drain pan for horizontal version with right water connections Coppia zoccoli bassi H = 90 mm per versioni incasso IV / Pair of feet H= 90 mm for concealed version IV Coppia zoccoli preverniciati bassi H = 90 mm per versioni con mantello MV Prepainted pair of feet H= 90 mm for cabinet version MV Plenum diritto di mandata aria per tutte le versioni da incasso (escluso modello IVP) Delivery straight plenum for all concealed versions (IVP model excluded) Plenum diritto di aspirazione aria per tutte le versioni da incasso (escluso modello IVP) Intake straight plenum for all concealed versions (IVP model excluded) Plenum 90 di mandata aria per tutte le versioni da incasso (escluso modello IVP) Delivery 90 plenum duct connection for all concealed versions (IVP model excluded) Plenum 90 di aspirazione aria per tutte le versioni da incasso (escluso modello IVP) Intake 90 plenum duct connection for all concealed versions (IVP model excluded) Prolunga telescopica mm per tutte le versioni da incasso (escluso modello IVP) Telescopic extension 0-100mm for all concealed versions (IVP model excluded) Bocchetta di mandata aria per tutte le versioni da incasso (escluso modello IVP) Delivery louver for all concealed versions (IVP model excluded) Griglia di aspirazione aria con filtro per tutte le versioni da incasso (escluso modello IVP) Intake louver with filter for all concealed versions (IVP model excluded) Batteria aggiuntiva / Additional coil SIGLA 3VEI 3TEI 3TAEI 3TADEI TAE TAD TM STB KEV2 KEV2A BV BOSX BODX ZI ZM PM PA 90CM 90CA PT BM GA BAT

61 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE MV MO SCHEDA TECNICA 40C Technical sheet 40C Modello verticale MV-AI MV-AI vertical model H L L A = = Attacchi idraulici 40 Ø 1/2" Scarico condensa Ø S Dimensioni in mm Modello verticale MV-AF MV-AF vertical model H L A L A = = Attacchi idraulici Ø 1/2" Scarico condensa Ø 21 S Dimensioni in mm Modello orizzontale MO-AP MO-AP horizontal model S H L Scarico condensa Ø L A A Attacchi idr. Ø 1/2" Modello orizzontale MO-AI MO-AI horizontal model S H L L A Attacchi idr. Ø 1/2" Scarico condensa Ø Modello Model Impianto a 2 tubi / (2-pipe system) Dimensioni / Dimensions L mm H mm S mm A mm Peso netto Impianto a 2 tubi / (2-pipe system) kg 15 18,5 19,3 25,2 29,3 29, ,5

62 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE IVO SCHEDA TECNICA 40C Technical sheet 40C Modello IVO-AP installazione verticale IVO-AP model vertical installation H L L 105 A A 40 Attacchi idraulici Ø 1/2" A 60 S Scarico condensa Ø = = Scarico condensa Ø Modello IVO-AF installazione verticale IVO-AF model vertical installation H L A 40 L 105 A Attacchi idraulici Ø 1/2" S Scarico condensa Ø = = Scarico condensa Ø 21 Modello IVO-AP installazione orizzontale IVO-AP model horizontal installation S H L A 40 L 105 A Attacchi idraulici Ø 1/2" A 60 Scarico condensa Ø = = Scarico condensa Ø 21 Modello IVO-AF installazione orizzontale IVO-AF model horizontal installation S H L Modello Model Impianto a 2 tubi / (2-pipe system) Dimensioni / Dimensions L mm H mm S mm A mm Peso netto Impianto a 2 tubi / (2-pipe system) kg 11, , ,3 23,3 27,2 31,1

63 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE IV IVP SCHEDA TECNICA 40C Technical sheet 40C Modello verticale IV-MF IV-MF vertical model Modello Model Impianto a 2 tubi / (2-pipe system) Dimensioni / Dimensions L mm H mm S mm A mm Peso netto Impianto a 2 tubi / (2-pipe system) kg 11, , L Ln 25 Sn = Modello verticale IVP-AFMF IVP-AFMF vertical model 25 Ln Hn = 620 H = Hn = 620 H = L 20 H = 670 Modello Model Impianto a 2 tubi / (2-pipe system) Dimensioni Dimensions Pannello frontale Front panel L mm Falso telaio False frame Ln mm Pannello frontale Front panel H mm Falso telaio False frame Hn mm Pannello frontale Front panel S mm Falso telaio False frame Sn mm Peso netto Impianto a 2 tubi / (2-pipe system) kg 22 24,5 26,3 33,2 38,3 38, ,5

64 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE IVPD CLIMATIZZATORE Wall mounted air conditioners SCHEDA TECNICA 40C Technical sheet 40C Modello verticale IVPD-AFMF IVPD-AFMF vertical model 175,5 L2 120 H1 H 55,5 L1 B B1 B B1 A C L Modello Impianto a 2 tubi / (2-pipe system) Model Dimensioni / Dimensions A mm B mm C mm L mm B1 mm L1 mm H1 mm L2 mm H mm 2241,5 2241,5 2241,5 2241,5 2241,5 Peso netto Impianto a 2 tubi / (2-pipe system) kg 38,5 39, ,7 58,7

65 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE MV MO IV IVO IVP IVPD Dati tecnici / Technical Data Modelli Models Potenzialità termica (1) Heating capacity (1) kw (max) 3,65 5,18 5,78 7,10 8,5 10,47 11,69 16,25 kw (med) 3,25 4,61 5,14 6,46 7,73 9,52 10,75 14,95 kw (min) 2,59 3,68 4,10 5,25 6,29 7, ,51 Potenza termica (2) Heating capacity (2) kw 2,09 3,1 3,33 4,13 5,04 6,16 6,97 9,06 Portata d acqua (1) Water flow (1) l/h Perdite di carico (1) Loss of charge (1) kpa 4,9 10,9 18,2 25,3 13,9 20,2 27,9 11,5 Pot. frigorifera totale (3) Refrigerating capacity (3) kw (max) 1,53 2,1 2,36 3,2 4,02 5,03 5,62 7,01 kw (med) 1,39 1,91 2,15 2,94 3,70 4,62 5,23 6,52 kw (min) 1,15 1,57 1,77 2,46 3,09 3,87 4,55 5,68 Pot. frigorifera sensibile (3) Refrigerating cap. sensible (3) kw (max) 1,17 1,62 1,67 2,08 2,48 3,25 3,62 4,86 kw (med) 1,04 1,44 1,49 1,87 2,23 2,92 3,29 4,42 kw (min) 0,81 1,12 1,15 1,49 1,78 2,34 2,75 3,69 Portata d acqua (3) Water flow (3) l/h Perdite di carico (3) Loss of charge (3) kpa 4,8 11,7 17,9 28,8 17,3 25, ,9 Potenzialità termica (1) Heating capacity (1) kw (max) 1,89 2,98 3,91 5,65 6,39 8,80 Batteria aggiuntiva (1 rango) Additional coil (1 row) kw (med) 1,70 2,68 3,56 5,15 5,89 8,14 kw (min) 1,36 2,14 2,88 4,19 4,94 6,87 Portata acqua (1) Water flow (1) l/h Batteria aggiuntiva (1 rango) Additional coil (1 row) Perdite di carico acqua (1) Loss of charge (1) kpa Batteria aggiuntiva (1 rango) Additional coil (1 row) Portata aria Air flow m 3 /h (max) m 3 /h (med) m 3 /h (min) Pressione sonora (4) Sound pressure (4) db(a) (max) db(a) (med) db(a) (min) Potenza sonora Sound power db(a) (max) db(a) (med) db(a) (min) Numero ventilatori Fan number n Potenza max. motore Max power input fan motor W Corrente max assorbita Max current absorbed A 0,15 0,27 0,27 0,33 0,33 0,47 0,57 0,98 Alimentazione Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Attacchi batteria principale (5) Connection main coil (5) Ø 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Attacchi batteria aggiuntiva (5) Connection additional coil (5) Ø 1/2 1/2 1/2 1/2 1/2 1/2 Numero ranghi Number row n batteria principale main coil Contenuto acqua Water quantity batteria principale main coil l 0,61 0,92 1,22 1,22 1,53 1,53 1,83 2,14 batteria aggiuntiva additional coil l 0,20 0,31 0,41 0,51 0,61 0,71 Attacco scarico condensa Connection drain tube versione verticale vertical version Ø versione orizzontale horizontal version Ø Peso netto vers. con mantello Weight net vers. with cover kg 15 18,5 19,3 25,2 29,3 29, ,5 con batteria aggiuntiva with additional coil kg 18,8 19,6 26,5 31, ,5 Peso netto vers. ad incasso Weight net vers. built-in kg 11, , ,3 23,3 27,2 31,1 con batteria aggiuntiva with additional coil kg ,2 25,2 29,2 35,1 (1) Riscaldamento: Temperatura aria ambiente 20 C Temperatura acqua ingresso 70 C Dt acqua 10 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (2) Riscaldamento: Temperatura aria ambiente 20 C Temperatura acqua ingresso 50 C Portata acqua come in raffreddamento - massima velocità del ventilatore (3) Raffreddamento: Temperatura aria ambiente 27 C b.s., 19 C b.u. Temperatura acqua ingresso 7 C Dt acqua 5 C alla massima velocità del ventilatore per media e minima velocità portata acqua come alla massima velocità (4) Pressione sonora: Misurata in camera semiriverberante di 100 m 3 e con tempo di riverberazione Tr di 0,5 s (5) Attacchi batteria di serie a sinistra (1) Heating: Room air temperature 20 C Water inlet temperature 70 C Water Dt 10 C maximum speed For medium and low speed, water flow rate remains same as at maximum speed (2) Heating: Room air temperature 20 C Water inlet temperature 50 C Water flow rate same as in cooling operation - maximum speed (3) Cooling: Room air temperature 27 C d.b., 19 C w.b. Water inlet temperature 7 C Water Dt 5 C maximum speed For medium and low speed, water flow rate remains same as at maximum speed (4) Sound pressure: measured in an 100 m 3 semi-reverberant test chamber with reverberation time Tr = 0,5 s (5) Connection exchange left standard I ventilconvettori possono essere forniti, a richiesta, con batteria aggiuntiva installata. (Disponibilità circa 30 giorni dalla conferma dell ordine). ON REQUEST fan coils can be supplied with additional coil installed. ( Available in about 30 days from the order confirmation).

66 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE MV MO IV IVO IVP IVPD Verticale a parete e pavimento - aspirazione inferiore Vertical wall and floor version - lower inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale a parete e pavimento - 1 batteria (impianto a 2 tubi) Vertical fan-coil wall and floor version - 1 coil (2 pipe system) MV 15 AI 1,53 2, ,60 MV 20 AI 2,10 3, ,00 MV 25 AI 2,36 3, ,60 MV 30 AI 3,20 4, ,40 MV 40 AI 4,02 5, ,40 MV 50 AI 5,03 6, ,40 MV 60 AI 5,62 6, ,00 MV 70 AI 7,01 9, ,00 Verticale a parete e pavimento - aspirazione frontale Vertical wall and floor version - front inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale a parete e pavimento - 1 batteria (impianto a 2 tubi) Vertical fan-coil wall and floor version - 1 coil (2 pipe system) MV 15 AF 1,53 2, ,30 MV 20 AF 2,10 3, ,40 MV 25 AF 2,36 3, ,20 MV 30 AF 3,20 4, ,20 MV 40 AF 4,02 5, ,40 Orizzontale a soffitto - aspirazione posteriore Horizontal ceiling version - rear inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore orizzontale a soffitto - 1 batteria (impianto a 2 tubi) Horizontal fan-coil ceiling version - 1 coil (2 pipe system) MO 15 AP 1,53 2, ,00 MO 20 AP 2,10 3, ,30 MO 25 AP 2,36 3, ,80 MO 30 AP 3,20 4, ,60 MO 40 AP 4,02 5, ,50 A richiesta. (Disponibilità circa 30 giorni dalla conferma dell ordine) On request. (Available in about 30 days from the order confirmation) (1) Dati riferiti alle seguenti condizioni: acqua 7/12 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. / Data refer to the following conditions: water 7/12 C - Inlet temperature air 27 C d.b. / 19 C w.b.. (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. / Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b..

67 Ventilconvettori / Fan coils Ventilconvettori Fan coils SILENCE MV MO IV IVO IVP IVPD Orizzontale a soffitto - aspirazione inferiore Horizontal ceiling version - lower inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore orizzontale a soffitto - 1 batteria (impianto a 2 tubi) Horizontal fan-coil ceiling version - 1 coil (2 pipe system) MO 15 AI 1,53 2, ,30 MO 20 AI 2,10 3, ,20 MO 25 AI 2,36 3, ,80 MO 30 AI 3,20 4, ,80 MO 40 AI 4,02 5, ,20 MO 50 AI 5,03 6, ,20 MO 60 AI 5,62 6, ,80 MO 70 AI 7,01 9, ,60 Incasso verticale/orizzontale aspirazione posteriore Vertical/horizontal built-in version rear inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore incasso verticale/orizzontale - 1 batteria (impianto a 2 tubi) Vertical/horizontal fan-coil built-in version - 1 coil (2 pipe system) IVO 15 AP 1,53 2, ,70 IVO 20 AP 2,10 3, ,40 IVO 25 AP 2,36 3, ,40 IVO 30 AP 3,20 4, ,70 IVO 40 AP 4,02 5, ,70 IVO 50 AP 5,03 6, ,70 IVO 60 AP 5,62 6, ,30 IVO 70 AP 7,01 9, ,20 Incasso verticale/orizzontale aspirazione frontale Vertical/horizontal built-in version front inlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore incasso verticale/orizzontale - 1 batteria (impianto a 2 tubi) Vertical/horizontal fan-coil built-in version - 1 coil (2 pipe system) IVO 15 AF 1,53 2, ,70 IVO 20 AF 2,10 3, ,30 IVO 25 AF 2,36 3, ,30 IVO 30 AF 3,20 4, ,40 IVO 40 AF 4,02 5, ,30 IVO 50 AF 5,03 6, ,30 A richiesta. (Disponibilità circa 30 giorni dalla conferma dell ordine) On request. (Available in about 30 days from the order confirmation) (1) Dati riferiti alle seguenti condizioni: acqua 7/12 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. / Data refer to the following conditions: water 7/12 C - Inlet temperature air 27 C d.b. / 19 C w.b.. (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. / Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b..

68 Ventilconvettori / Fan coils Ventilconvettori Fan coils CLIMATIZZATORE Wall mounted air conditioners SILENCE MV MO IV IVO IVP IVPD Incasso verticale a parete e pavimento mandata frontale Vertical built-in version for wall and floor installation front outlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore incasso verticale a parete e pavimento - 1 batteria (impianto a 2 tubi) Vertical fan-coil built-in version for wall and floor installation - 1 coil (2 pipe system) IV 15 MF 1,53 2, ,10 IV 20 MF 2,10 3, ,10 IV 25 MF 2,36 3, ,10 IV 30 MF 3,20 4, ,00 Incasso verticale con pannello piano, aspirazione e mandata frontali Vertical built-in version with cover panel, front inlet and outlet Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale con pannello piano - 1 batteria (impianto a 2 tubi) Vertical fan-coil with cover panel built-in version - 1 coil (2 pipe system) IVP 15 AFMF 1,53 2, ,00 IVP 20 AFMF 2,10 3, ,40 IVP 25 AFMF 2,36 3, ,50 IVP 30 AFMF 3,20 4, ,70 IVP 40 AFMF 4,02 5, ,50 IVP 50 AFMF 5,03 6, ,50 IVP 60 AFMF 5,62 6, ,50 IVP 70 AFMF 7,01 9, ,00 Incasso verticale con pannello frontale e canale di mandata Vertical built-in version with front panel and outlet duct Modello Condizionamento Riscaldamento Codice Euro Model Cooling Heat pump Code kw (1) kw (2) Ventilconvettore verticale con pannello piano - 1 batteria (impianto a 2 tubi) Vertical fan-coil with cover panel built-in version - 1 coil (2 pipe system) IVPD 20 AFMF 2,10 3, ,00 IVPD 25 AFMF 2,36 3, ,40 IVPD 30 AFMF 3,20 4, ,00 IVPD 40 AFMF 4,02 5, ,00 IVPD 50 AFMF 5,03 6, ,00 A richiesta. (Disponibilità circa 30 giorni dalla conferma dell ordine) On request. (Available in about 30 days from the order confirmation) (1) Dati riferiti alle seguenti condizioni: acqua 7/12 C e temperatura aria ingresso 27 C b.s. / 19 C b.u. Data refer to the following conditions: water 7/12 C - Inlet temperature air 27 C d.b. / 19 C w.b.. (2) Dati riferiti alle seguenti condizioni: acqua ingresso 50 C e temperatura aria ingresso 20 C b.s. / 15 C b.u. Data refer to the following conditions: inlet water 50 C and inlet temperature air 20 C d.b. / 15 C w.b..

69 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua Air cooled liquid chillers and heat pumps SILENCE MV MO IV IVO IVP IVPD 3VEI Pannello comando a bordo macchina Control panel on board unit Modello Codice Euro Model Code Con selettore 3 velocità + selettore OFF - Estate - Inverno; varie possibilità di collegamento With 3-speed selector + OFF selector - Summer - Winter; various connecting possibilities NB. Non compatibile con i modelli MO... / Not compatible with models MO ,42 3TEI Pannello comando a bordo macchina elettronico Electronic control panel on board unit Modello Codice Euro Model Code Con Termostato ambiente + selettore 3 velocità + selettore OFF - Estate - Inverno; Comanda valvole (KEV2 - KEV2A); varie possibilità di collegamento With room thermostat + 3-speed selector + OFF selector - Summer - Winter; Controls valves (KEV2 - KEV2A); various connecting possibilities NB. Non compatibile con i modelli MO... / Not compatible with models MO ,44 3TAEI Pannello comando a bordo macchina elettronico Electronic control panel on board unit Modello Codice Euro Model Code A microprocessore con Termostato ambiente + selettore 3 velocità e Auto + selettore OFF - Estate - Inverno, con funzione antistratificazione; Comanda valvole (KEV2 - KEV2A); varie possibilità di collegamento With microprocessor and room thermostat + 3-speed and Auto selector + OFF selector - Summer - Winter, with anti-stratification fuction; Controls valves (KEV2 - KEV2A); various connecting possibilities NB. Non compatibile con i modelli MO... / Not compatible with models MO ,50 3TADEI Pannello comando a bordo macchina elettronico a microprocessore Digitale configurabile On-board configurable electronic control panel with digital microprocessor Modello Codice Euro Model Code Con selettore 3 velocità + Auto, selettore Estate / Inverno, On/Off, visualizzazione temperatura ambiente, funzione economy, funzione antistratificazione, avviso filtro sporco, pilotaggio valvole (KEV2 - KEV2A) With 3-speed + Auto selector, Summer / Winter selector, On/Off, room temperature display, Economy function, anti-stratification function, dirty filter notification, valve control (KEV2 - KEV2A) NB. Non compatibile con i modelli MO... / Not compatible with models MO ,70 STB Sonda temperatura acqua Water temperature sensor Modello Codice Euro Model Code Sonda temperatura acqua con cavo da 1m compatibile con comando 3TADEI Water temperature sensor with 1m cable compatible with 3TADEI control ,05

70 Ventilconvettori / Fan coils Accessori Accessories CLIMATIZZATORE Wall mounted air conditioners SILENCE MV MO IV IVO IVP IVPD TAE Termostato ambiente elettronico per ventilconvettori (PER INSTALLAZIONE A PARETE) Electronic control panel for fan coils (WALL MOUNTED VERSION) Modello Codice Euro Model Code Selettore 3 velocità, estate / off / inverno, manopola regolazione temperatura ambiente, pilotaggio valvole on/off (KEV2 - KEV2A), per installazione a parete, sonda ambiente integrata 3 speeds switch + summer / off / winter switch + temperature thermostat, driver for on/off valves (KEV2 - KEV2A) for wall mounted with room sensor inside ,76 Dati tecnici Alimentazione 230V ~ -15% ± 10% 50Hz 24V ~ -15% ± 10% 50Hz Campo di regolazione 5 35 C Potenza assorbita 1,2 W Temperatura di funzionamento 0 40 C Grado di protezione IP 20 Dimensioni 129 x 96 x 37 mm Technical data Power supply 230V ~ -15% ± 10% 50Hz 24V ~ -15% ± 10% 50Hz Setting 5 35 C Power absorbed 1,2 W Temperature 0 40 C Protection rate IP 20 Dimensions 129 x 96 x 37 mm TAD Termostato ambiente digitale per ventilconvettori (PER INSTALLAZIONE A PARETE) Digital control panel for fan coils (WALL MOUNTED VERSION) Modello Codice Euro Model Code Selettore 3 velocità + auto, estate / inverno, on/off, visualizzazione temperatura ambiente, funzione economy, avviso filtro sporco, pilotaggio valvole (KEV2 - KEV2A), per install. a parete, sonda ambiente integrata 3 speeds + auto switch, summer / winter, on/off, room temperature display, economy function, filter signal, driver for valves (KEV2 - KEV2A) - for wall mounted with room sensor inside ,20 Dati tecnici Alimentazione 230V ~ -15% ± 10% 50Hz Campo di regolazione C Potenza assorbita 3VA Temperatura di funzionamento 0 40 C Grado di protezione IP 20 Dimensioni 129 x 96 x 37 mm Prestazioni Configurabile in base al tipo di impianto (2 tubi, 4 tubi, resistenza elettrica, ecc.) Regolazione automatica o manuale della velocità Controllo di attuatori ON/OFF, PWM, 3 punti Range della manopola del setpoint diverso per riscaldamento e raffreddamento Funzioni speciali: Economy, avviso Filtro sporco, controllo finestra Ingresso per selezione EST/INV centralizzata Alimentazione selezionabile 230V o 24V Technical data Power supply 230V ~ -15% ± 10% 50Hz Setting C Power absorbed 3VA Temperature 0 40 C Protection rate IP 20 Dimensions 129 x 96 x 37 mm Ratings Programmable in according to the type of system (2 pipe, 4 pipe, electric resistance, ecc.) Automatic or manually adjustment of speed Control ON/OFF, PWM, 3 points Range of setpoint knob unlike for heating and cooling Special function: Economy, advertisement dirty filter, control window Input for selection summer/winter Power 230V or 24V

71 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua Air cooled liquid chillers and heat pumps SILENCE MV MO IV IVO IVP IVPD TM Termostato minima temperatura acqua Water low temperature thermostat Modello Codice Euro Model Code TM32 Termostato minima temperatura acqua 32 C ,05 Water low temperature thermostat 32 C TM42 Termostato minima temperatura acqua 42 C ,03 Water low temperature thermostat 42 C In abbinamento a tutti i comandi per Fan Coil / For all the control panels ZI ZM Coppia zoccoli Feet pair Modello Codice Euro Model Code ZI Coppia zoccoli h = 90 mm per versioni incasso IV - IVO ,58 Feet pair h = 90 mm for cassette versions IV - IVO ZM Coppia zoccoli h = 90 mm per versioni MV - MO ,29 Feet pair h = 90 mm for versions MV - MO KEV2 Kit valvola motorizzata a 3 vie per impianto a 2 tubi (1 batteria) Kit 3-ways motorized valve for a 2 pipe system (1 coil) Modello Codice Euro Model Code 1 valvola a tre vie 3/4 con Kvs 2,5 + 1 servocomando elettrotermico on/off 230V + kit tubi rame e raccordi 3/4 3-ways valve Kvs 2,5 + 1 on/off 230V electrothermic actuator + kit copper pipes and fittings ,30 KEV2A Kit valvola motorizzata a 3 vie per batteria aggiunta Kit 3-ways motorized valve for additional coil Modello Codice Euro Model Code 1 valvola a tre vie 1/2 + 1 servocomando elettrotermico on/off 230V + kit tubi rame e raccordi 1/2 3-ways valve + 1 on/off 230V electrothermic actuator + kit copper pipes and fittings ,90 Bacinella ausiliaria / Auxiliary drain pan Modello Codice Euro Model Code BV Per tutte le versioni verticali a parete e pavimento ,95 For all vertical wall and floor versions BOSX Per tutte le versioni orizzontali a soffitto con attacchi sx ,84 For all horizontal ceiling versions with left connections BODX Per tutte le versioni orizzontali a soffitto con attacchi dx ,84 For all horizontal ceiling versions with right connections

72 Ventilconvettori / Fan coils Accessori Accessories CLIMATIZZATORE SILENCE MV MO IV IVO IVP Batteria aggiuntiva Additional coil Wall mounted air conditioners Modello Codice Euro Model Code BAT15 per mod. 15 / for mod ,80 BAT20 per mod. 20 / for mod ,60 BAT30 per mod. 30 / for mod ,30 BAT50 per mod / for mod ,00 PM Plenum per ventilconvettori ad incasso Plenum for cassette fan coils Modello Codice Euro Model Code PM15 Plenum diritto di mandata aria isolato mod ,13 Insulated air supply straight plenum mod. 15 PM20-25 Plenum diritto di mandata aria isolato mod ,35 Insulated air supply straight plenum mod PM30 Plenum diritto di mandata aria isolato mod ,58 Insulated air supply straight plenum mod. 30 PM40-50 Plenum diritto di mandata aria isolato mod ,81 Insulated air supply straight plenum mod PT PT15 Prolunga telescopica mm isolata mod ,66 Insulated telescopic extension mm mod. 15 PT20-25 Prolunga telescopica mm isolata mod ,16 Insulated telescopic extension mm mod PT30 Prolunga telescopica mm isolata mod ,34 Insulated telescopic extension mm mod. 30 PT40-50 Prolunga telescopica mm isolata mod ,61 Insulated telescopic extension mm mod Plenum per ventilconvettori ad incasso Plenum for cassette fan coils Modello Codice Euro Model Code PA15 Plenum diritto di aspirazione aria mod ,13 Air intake straight plenum mod. 15 PA20-25 Plenum diritto di aspirazione aria mod ,65 Air intake straight plenum mod PA30 Plenum diritto di aspirazione aria mod ,22 Air intake straight plenum mod. 30 PA40-50 Plenum diritto di aspirazione aria mod ,73 Air intake straight plenum mod Bocchetta per ventilconvettori ad incasso Outlet grid for cassette fan coils Modello Codice Euro Model Code BM15 Bocchetta di mandata aria mod ,55 Air supply outlet grid mod.15 BM20-25 Bocchetta di mandata aria mod ,02 Air supply outlet grid mod BM30 Bocchetta di mandata aria mod ,48 Air supply outlet grid mod. 30 BM40-50 Bocchetta di mandata aria mod ,00 Air supply outlet grid mod

73 Ventilconvettori / Fan coils Accessori Refrigeratori Accessories e Pompe di calore Aria-Acqua SILENCE MV MO IV IVO IVP Plenum e griglie per ventilconvettori ad incasso Plenum and grid for cassette fan coils Air cooled liquid chillers and heat pumps Modello Codice Euro Model Code 90CM15 Plenum 90 di mandata aria isolato mod ,99 Insulated air supply 90 plenum mod CM20-25 Plenum 90 di mandata aria isolato mod ,40 Insulated air supply 90 plenum mod CM30 Plenum 90 di mandata aria isolato mod ,70 Insulated air supply 90 plenum mod CM40-50 Plenum 90 di mandata aria isolato mod ,11 Insulated air supply 90 plenum mod CA15 Plenum 90 di aspirazione aria mod ,02 Air intake 90 plenum mod CA20-25 Plenum 90 di aspirazione aria mod ,48 Air intake 90 plenum mod CA30 Plenum 90 di aspirazione aria mod ,11 Air intake 90 plenum mod CA40-50 Plenum 90 di aspirazione aria mod ,58 Air intake 90 plenum mod Griglia per ventilconvettori ad incasso Plenum and grid for cassette fan coils Modello Codice Euro Model Code GA15 Griglia di aspirazione aria con filtro mod ,65 Air intake grid with filter mod. 15 GA20-25 Griglia di aspirazione aria con filtro mod ,11 Air intake grid with filter mod GA30 Griglia di aspirazione aria con filtro mod ,58 Air intake grid with filter mod. 30 GA40-50 Griglia di aspirazione aria con filtro mod ,08 Air intake grid with filter mod

SLI PLUS CARATTERISTICHE

SLI PLUS CARATTERISTICHE SLI Ventilconvettore ad incasso CARATTERISTICHE CLIMATIZZA, DEUMIDIFICA, RISCALDA E FILTRA SPESSORE DI soli,6 cm Gamma composta da 5 modelli di potenza: SLI 00, SLI 400, SLI 600, SLI 800, SLI 000 Versatilità

Dettagli

ENERGY-EFFICIENT HOME VENTILATION SYSTEMS

ENERGY-EFFICIENT HOME VENTILATION SYSTEMS SISTEMI DI RECUPERO RESIDENZIALE HOME RECOVERY SYSTEMS RECUPERO DI CALORE AD ALTA EFFICIENZA HIGH EFFICIENCY HEAT RECOVERY VENTILAZIONE A BASSO CONSUMO LOW ENERGY VENTILATION SISTEMI DI RICAMBIO CONTROLLATO

Dettagli

Terminali idronici ad Aria. Hydronic Air Terminal Units. Terminali idronici ad aria / Hydronic Air Terminal Units

Terminali idronici ad Aria. Hydronic Air Terminal Units. Terminali idronici ad aria / Hydronic Air Terminal Units Terminali idronici ad Aria Hydronic Air Terminal Units Terminali idronici ad aria / Hydronic Air Terminal Units 156 Indice Index Ventilconvettori Fan coils Modelli a Parete da 2 a 4,7 kw Wall fan coil

Dettagli

Indice. Index. Ventilconvettori a parete Wall fan coils version. Ventilconvettori a cassette Cassette fan coils version

Indice. Index. Ventilconvettori a parete Wall fan coils version. Ventilconvettori a cassette Cassette fan coils version 178 Indice Index Ventilconvettori a parete Wall fan coils version Modelli da 2,1 a 4,7 kw From 2,1 to 4,7 kw models pag. 180 Ventilconvettori a cassette Cassette fan coils version Modelli da 2,6 a 7,3

Dettagli

Unità terminali ad aria per uso residenziale. Terminal air units for residential use

Unità terminali ad aria per uso residenziale. Terminal air units for residential use Unità terminali ad aria per uso residenziale Terminal air units for residential use Unità terminali ad Aria per il residenziale Fan coil for residential application Benessere in tutte le stagioni I ventilconvettori

Dettagli

Vasche. Bathtub. Calypso

Vasche. Bathtub. Calypso 342 Vasche Calypso 343 Calypso Vasca rettangolare / Rectangular bathtub cm 150x capacità / capacity 150 lt. cm 160x capacità / capacity 160 lt. cm 1x capacità / capacity 1 lt. cm 1x75 capacità / capacity

Dettagli

Unico Easy - Installabile a pavimento - Solo freddo 0536223 Unico Easy SF 2,1-01056 1.627,000

Unico Easy - Installabile a pavimento - Solo freddo 0536223 Unico Easy SF 2,1-01056 1.627,000 Climatizzazione OLS 3 Monovolume unico Unico inverter - Installabile in alto e in basso - Solo Capacità nominale (min/max) Descrizione risc. 0536212 Unico Inverter 9 SF 2,3 (1,4/2,7) 01068 2.790,000 0536211

Dettagli

TERMOVENTILANTI EBH EDS INTEGRATED COMFORT SYSTEMS

TERMOVENTILANTI EBH EDS INTEGRATED COMFORT SYSTEMS IT TERMOVENTILANTI EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS TERMOVENTILANTI EBH EDS Le unità termoventilanti da incasso delle serie EBH - EDS, grazie ai loro ventilatori ad alta prevalenza, sono indicate

Dettagli

MODULO IDRAULICO DI INTEGRAZIONE E ACS

MODULO IDRAULICO DI INTEGRAZIONE E ACS MODULO IDRAULICO DI INTEGRAZIONE E ACS Hot sanitary water production and integration hydraulic module Accessori pompe di calore INSTALLAZIONE E USO Installation and use I Il presente documento è da considerarsi

Dettagli

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS I sistemi mod. i-léd SOLAR permettono di alimentare un carico sia in bassa tensione 12-24V DC, sia a 230v AC, tramite alimentazione

Dettagli

6 44 kw. Epsilon Echos APPLIED. < Applied

6 44 kw. Epsilon Echos APPLIED. < Applied 6 44 kw Epsilon Echos EC Una vasta e completa gamma di chiller e pompe di calore aria/acqua composta da dodici modelli, concepita e sviluppata per fornire massimo comfort e versatilità. Configurazioni

Dettagli

MAGNET LINK SURFACE MOUNTED

MAGNET LINK SURFACE MOUNTED MAGNET LINK SURFACE MOUNTED unonovesette LIGHTING INSTRUMENTS MAGNET LINK SURFACE MOUNTED is a low-voltage magnetic track in Class III SELV, Designed to power constant-voltage LED luminaires. The 4 conductors

Dettagli

OMNIA RADIANT VENTILCONVETTORE CON PIASTRA RADIANTE IL VENTILCONVETTORE CON 3 MODALITÀ DI RISCALDAMENTO

OMNIA RADIANT VENTILCONVETTORE CON PIASTRA RADIANTE IL VENTILCONVETTORE CON 3 MODALITÀ DI RISCALDAMENTO RADIANT VENTILCONVETTORE CON PIASTRA RADIANTE IL VENTILCONVETTORE CON 3 MODALITÀ DI RISCALDAMENTO Installazione a parete o a pavimento Versioni on-off e ad Inverter, abbinabile al sistema di gestione VMF

Dettagli

6 44 kw. Epsilon Echos series APPLIED. < Applied. An extensive and complete range of chillers and heatpumps composed of twelve models, conceived and

6 44 kw. Epsilon Echos series APPLIED. < Applied. An extensive and complete range of chillers and heatpumps composed of twelve models, conceived and 6 44 kw Epsilon Echos series EC Una vasta e completa gamma di chiller e pompe di calore aria/acqua composta da dodici modelli, concepita e sviluppata per fornire il massimo comfort e il massimo livello

Dettagli

kw. Lambda Echos APPLIED. < Applied

kw. Lambda Echos APPLIED. < Applied 54 327 kw Lambda Echos Condizionatore d aria autonomo solo freddo o pompa di calore con compressori scroll in versione Roof-Top. Configurazioni HP: Condizionatore tipo in pompa di calore reversibile LN:

Dettagli

SILENCE THIN ETM ETI. CLIMATIZZATORE Wall mounted air conditioners. Ventilconvettori Fan coils DC INVERTER

SILENCE THIN ETM ETI. CLIMATIZZATORE Wall mounted air conditioners. Ventilconvettori Fan coils DC INVERTER Ventilconvettore per il Riscaldamento ed il Raffrescamento di ambienti ad uso residenziale con tecnologia DC-Inverter Monobloc heat pump for Heating and Cooling Residential rooms with plant management

Dettagli

Your home comfort has a new shape. Find out how it works

Your home comfort has a new shape. Find out how it works Your home comfort has a new shape Find out how it works CUBODOMO allows you to manage and monitor your entire home s temperature, from WHEREVER YOU ARE CUBODOMO ti consente di gestire e monitorare la temperatura

Dettagli

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

RPS TL System. Soluzioni per l energia solare Solutions for solar energy Soluzioni per l energia solare Solutions for solar energy RPS TL da 280 kwp a 1460 kwp RPS TL from 280 kwp to 1460 kwp RPS TL System L elevata affidabilità e la modularità della costruzione sono solo alcuni

Dettagli

ventilatori centrifughi a semplice aspirazione pale avanti serie VZ centrifugal fans single inlet forward bladed VZ serie

ventilatori centrifughi a semplice aspirazione pale avanti serie VZ centrifugal fans single inlet forward bladed VZ serie ventilatori centrifughi a semplice aspirazione pale avanti serie VZ centrifugal fans single inlet forward bladed VZ serie ventilatori centrifughi a semplice aspirazione pale avanti serie VZ centrifugal

Dettagli

TORRINO DI ESTRAZIONE AD ALTO RENDIMENTO

TORRINO DI ESTRAZIONE AD ALTO RENDIMENTO MTV TORRINO DI ESTRAZIONE AD ALTO RENDIMENTO HIGH EFFICIENCY ROOF-UNITS EXHAUST FAN TORRINO DI ESTRAZIONE CENTRIFUGO CENTRIFUGAL ROOF-UNITS BASSA PRESSIONE LOW PRESSURE Portata/Flow rate: 4 190 Pressione/Pressure:

Dettagli

Diffusori ad alta induzione a geometria variabile High induction diffuser variable geometry

Diffusori ad alta induzione a geometria variabile High induction diffuser variable geometry Diffusori ad alta induzione a geometria variabile High induction diffuser variable geometry PRESENTAZIONE - OVERVIEW DESCRIZIONE Diffusori ad alta induzione, a geometria variabile mediante regolazione

Dettagli

Stilled - Stillens. Led lights E

Stilled - Stillens. Led lights E design: Studio Tecnico Ivela Grazie alla loro versatilità Stilled e Stillens si adattano ai più diversi contesti ambientali, esterni o interni. Molteplici le applicazioni, a parete per soluzioni scenografiche,

Dettagli

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no.

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no. Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no. 327/2011 In base alla direttiva ErP e al regolamento UE n. 327/2011, si impone

Dettagli

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION VERSIONE MANUALE CON VOLANTINO MANUAL VERSION WITH HANDWHEEL VERSIONE CON COMANDO PNEUMATICO A

Dettagli

Vasche. Bathtub. Sense Dual

Vasche. Bathtub. Sense Dual 56 Vasche Sense Dual 57 Sense Dual Vasca rettangolare / Rectangular bathtub cm 190x140 capacità / capacity 430 lt FINITURE DISPONIBILI / FEATURES Rubinetteria a bordo vasca con cascata d acqua Bath mounted

Dettagli

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED) Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED) Alimentatori elettronici con tensione di uscita stabilizzata per moduli LED di segnalazione. Led driver with

Dettagli

DC Inverter FANCOILS PER RISCALDAMENTO E RAFFRESCAMENTO AD ALTA EFFICIENZA HIGH EFFICIENCY HEATING AND COOLING FANCOILS

DC Inverter FANCOILS PER RISCALDAMENTO E RAFFRESCAMENTO AD ALTA EFFICIENZA HIGH EFFICIENCY HEATING AND COOLING FANCOILS FANCOILS PER RISCALDAMENTO E RAFFRESCAMENTO AD ALTA EFFICIENZA HIGH EFFICIENCY HEATING AND COOLING FANCOILS Cosa è Airleaf? Airleaf è un ventilconvettore alimentato ad acqua che racchiude in un solo apparecchio

Dettagli

CURVATURA - BENDING C50 ES

CURVATURA - BENDING C50 ES CURVATURA BENDING CURVATURA BENDING SPESSORE MASSIMO MAX thickness 5 mm Ø 38 4 mm Ø 42 3 mm Ø 50 C50 ES La curvatubi C50 ES è l attrezzatura ideale per piegare tubi rigidi oleodinamici in acciaio inox

Dettagli

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/33 48 36 Fax 057/33 61 27 info@pomac.be internet: www.pomac.

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/33 48 36 Fax 057/33 61 27 info@pomac.be internet: www.pomac. BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge UNITA LUBETOOL MC-EL-3P-4P-5P-6P-7P, MC-EL-3M-4M-5M-6M-7M, MC-EL-2P E MC- EL-2M Sono forniti completi di scatola di protezione metallica

Dettagli

Ventilatori Brushless modulanti a magneti permanenti con inverter, per uso continuo, a risparmio energetico e bassa rumorosità.

Ventilatori Brushless modulanti a magneti permanenti con inverter, per uso continuo, a risparmio energetico e bassa rumorosità. Scheda Tecnica: Piastra idronica SKUDO DC Inverter Codice scheda: XSCT00078 Data 15/11/2014 Famiglia: Recuperatori di calore Descrizione SKUDO è la piastra idronica con spessore di 13 cm e batteria di

Dettagli

Recuperatori di calore

Recuperatori di calore Recuperatori di calore UDE DEUMIDIFICATORI AD ALTA EFFICIENZA Air Control Srl via Luigi Biraghi 33-20159 Milano Tel +39 0245482147 Fax +39 0245482981 P.Iva 04805320969 Recuperatori di calore CARATTERISTICHE

Dettagli

NUOVO FCB NEW FAN COIL BEAM IL PASSATO INCONTRA IL FUTURO THE PAST MEETS THE FUTURE

NUOVO FCB NEW FAN COIL BEAM IL PASSATO INCONTRA IL FUTURO THE PAST MEETS THE FUTURE NUOVO FCB NEW FAN COIL BEAM IL PASSATO INCONTRA IL FUTURO THE PAST MEETS THE FUTURE Cos è? Perchè è nato questo prodotto? What is it? Whay this product was born? La nuova serie AIR GREEN è stata sviluppata

Dettagli

FLAT. VENTILCONVETTORI CENTRIFUGHI di SPESSORE RIDOTTO

FLAT. VENTILCONVETTORI CENTRIFUGHI di SPESSORE RIDOTTO FLAT VENTILCONVETTORI CENTRIFUGHI di SPESSORE RIDOTTO VENTILCONVETTORI CENTRIFUGHI di SPESSORE RIDOTTO FLAT Ventilconvettori centrifughi di spessore ridotto serie FLAT Design sobrio dalle linee gradevoli.

Dettagli

design by Simone Micheli

design by Simone Micheli design by Simone Micheli EWALL interactive backlight acoustic panel Innovativo pannello con triplice funzione: complemento d arredo fonoassorbente in tessuto COEX, modulo interattivo progettato per assemblare

Dettagli

INVERTER, MAI COSÌ EFFICIENTE

INVERTER, MAI COSÌ EFFICIENTE INVERTER, MAI COSÌ EFFICIENTE Unico Inverter è il climatizzatore senza unità esterna che grazie alla tecnologia inverter permette di risparmiare fino al 30%* rispetto ad un prodotto tradizionale. La gamma

Dettagli

> HMW LT POMPE DI CALORE ACQUA - ACQUA E BRINE - ACQUA PER INSTALLAZIONE ESTERNA O INTERNA. Gamma disponibile. Descrizione dell unità.

> HMW LT POMPE DI CALORE ACQUA - ACQUA E BRINE - ACQUA PER INSTALLAZIONE ESTERNA O INTERNA. Gamma disponibile. Descrizione dell unità. > HMW LT POMPE DI CALORE ACQUA - ACQUA E BRINE - ACQUA PER INSTALLAZIONE ESTERNA O INTERNA ECO-FRIENDLY Gamma disponibile REFRIGERANT GAS Tipologia di unità IH Pompa di calore IP Pompa di calore reversibile

Dettagli

FRAMES WINDOW TECHNOLOGY MOTTURA.COM

FRAMES WINDOW TECHNOLOGY MOTTURA.COM FRAMES WINDOW TECHNOLOGY MOTTURA.COM FRAMES UNA GAMMA DEDICATA Rollbox 40 e 60 sono tende a rullo filtranti ed oscuranti specifiche per installazione diretta senza foratura su serramenti in alluminio.

Dettagli

CFR MICRO E UNITÀ DI RECUPERO CALORE TOTALE AD ALTA EFFICIENZA HIGH EFFICIENCY TOTAL HEAT RECOVERY UNIT

CFR MICRO E UNITÀ DI RECUPERO CALORE TOTALE AD ALTA EFFICIENZA HIGH EFFICIENCY TOTAL HEAT RECOVERY UNIT Sistemi Integrati Condizionamento CFR MICRO E UNITÀ DI RECUPERO CALORE TOTALE AD ALTA EFFICIENZA HIGH EFFICIENCY TOTAL HEAT RECOVERY UNIT Con esclusivo sistema di sanificazione With exclusive purifying

Dettagli

Efp E 8-I (cod. 2C01102T)

Efp E 8-I (cod. 2C01102T) Efp E 8-I (cod. 2C01102T) Pompe di calore aria/acqua Inverter adatti per il riscaldamento, il raffrescamento e la produzione di acqua calda sanitaria di ambienti di piccole e medie dimensioni. Ideali per

Dettagli

AER Slim RESIDENTIAL DESIGN

AER Slim RESIDENTIAL DESIGN RESIDENTIAL DESIGN Estetica E DIMENSIONI MODELS S L I M F A N C O I L RIDOTTE AESTHETIC AND SMALL SIZE Eleganza pulita delle forme e il contenuto spessore, lo rende perfettamente integrabile nei vani ciechi

Dettagli

2" GAS 2" GAS 2" GAS 2-1/2" GAS 2-1/2" GAS 85 (1P) 150 (1P) 150 (1P) 190 (1P) 250 (1P)

2 GAS 2 GAS 2 GAS 2-1/2 GAS 2-1/2 GAS 85 (1P) 150 (1P) 150 (1P) 190 (1P) 250 (1P) RACA PLUS ENERGY Le unità RACA PLUS ENERGY sono studiate per soddisfare in modo completo qualunque esigenza ed applicativa grazie ad una gamma completa di modelli e configurazioni. Sono disponibili con

Dettagli

STAND ALONE LED PV KIT WITH ROAD ARMOR

STAND ALONE LED PV KIT WITH ROAD ARMOR STAND ALONE LED PV KIT WITH ROAD ARMOR COMPONENTS LED KIT SINGLE ARMOR Led road armor Pole head structure with outreach for road armor Ø 60mm Polycrystalline PV module Box with frame to hold the PV module

Dettagli

L INNOVAZIONE LEGATA ALLA TRADIZIONE

L INNOVAZIONE LEGATA ALLA TRADIZIONE L INNOVAZIONE LEGATA ALLA TRADIZIONE Riscaldamento, Raffrescamento e Deumidificazione L INNOVAZIONE CHE ORIENTA IL MERCATO V-Radiant è il nuovo ventilconvettore ibrido e radiatore di ECA Technology. Un

Dettagli

BUILT-IN HOODS COLLECTION

BUILT-IN HOODS COLLECTION BUILT-IN HOODS COLLECTION COLLECTION BUILT-IN Fabula 10 Heaven 2.0 11 Heaven Glass 2.0 11 SkyLift 6 SkyPad 10 BUILT-IN CABINET Inca Lux 13 Inca Lux Glass 13 Inca Plus HCS 14 Inca Smart HCS 14 Intra 18

Dettagli

AUTOMAZIONI PER PORTE BATTENTI

AUTOMAZIONI PER PORTE BATTENTI AUTOMAZIONI PER PORTE BATTENTI AUTOMATIONS FOR SWING DOORS Modernità, compattezza ed affidabilità: tre semplici concetti che riassumono al meglio le automazioni per porte battenti myone. Se a queste caratteristiche

Dettagli

LG NEWS FLASH Aprile 2013. Campagna pubblicitaria clima 2013

LG NEWS FLASH Aprile 2013. Campagna pubblicitaria clima 2013 Campagna pubblicitaria clima 2013 LG Electronics Italia S.p.A. e molto lieta di presentarvi la campagna pubblicitaria in corso su Il Sole 24 Ore, dove tutti i venerdi fino al 24 maggio troverete uno spazio

Dettagli

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod. 7111352

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod. 7111352 C L E A N I N G GARDEN LINE international CLEANING Revisione 6-09/2013 Cod. 7111352 Note Tecniche di Prodotto. I dati e le caratteristiche tecniche riportate nel presente Catalogo Generale non sono impegnativi.

Dettagli

Combinazioni serie IL-MIL + MOT

Combinazioni serie IL-MIL + MOT Combinazioni tra riduttori serie IL-MIL e MOT Combined series IL-MIL + MOT reduction units Combinazioni serie IL-MIL + MOT Sono disponibili varie combinazioni tra riduttori a vite senza fine con limitatore

Dettagli

Decoro su vetro a parete realizzato da: / Printed on glass to wall realized from:

Decoro su vetro a parete realizzato da: / Printed on glass to wall realized from: Decoro su vetro a parete realizzato da: / Printed on glass to wall realized from: Offi cina Novellini 334 Vasche Venus 335 Venus Vasca angolare / Corner bathtub INSTLLZIONE SOLO D NGOLO / CORNER INSTLLTION

Dettagli

No pump group / 1 pump group. 0, m3/h 1206A 1306A 1506A 1802A-2002A-2202A-2502A 2802A-3002A pump group for 1206A-1802A

No pump group / 1 pump group. 0, m3/h 1206A 1306A 1506A 1802A-2002A-2202A-2502A 2802A-3002A pump group for 1206A-1802A PREVALENZA DELLE POMPE E PERDITE DI CARICO DELL EVAPORATORE (lato acqua) PUMP: HEAD PRESSURE AND EVAPORATOR PRESSURE DROP (water side) No pump group / 1 pump group Kpa 350,0 300,0 250,0 200,0 150,0 100,0

Dettagli

OPZIONI. OPTIONALs. silenziosità unità carenate versatilità di utilizzo. low noise condensing careened units versatility of use and applications

OPZIONI. OPTIONALs. silenziosità unità carenate versatilità di utilizzo. low noise condensing careened units versatility of use and applications UNIBLOCK CU La nuova serie commerciale è caratterizzata dalla particolare tipologia costruttiva finalizzata alla riduzione del livello di rumorosità tramite l utilizzo di compressori in vani isolabili

Dettagli

Scheda elettrica per sistema di miscelazione a punto fisso

Scheda elettrica per sistema di miscelazione a punto fisso IT Scheda elettrica per sistema di miscelazione a punto fisso Art.: AC654 Alimentazione: 230 V AC Caratteristiche relé: 8A/250 V AC AC1 3A/250 V AC AC3 Il dispositivo è una scheda elettrica dotata di circuito

Dettagli

Sistemi di connessione Distribox e Spiderbox

Sistemi di connessione Distribox e Spiderbox Distribox and Spiderbox connectivity systems Very small and available in several variants to optimize use of available installation space. Robust design. Available working voltage: 12V, 24V, 110V or 240V;

Dettagli

Una Fusione di Tecnologia e Design. Technology and Design balance. Alette Contrapposte = Effetto Induzione Opposite Louvers = Induction Effect

Una Fusione di Tecnologia e Design. Technology and Design balance. Alette Contrapposte = Effetto Induzione Opposite Louvers = Induction Effect Una Fusione di Tecnologia e Design FX 05 Technology and Design balance Doppio ordine di alette orientabili per indirizzare il flusso d aria in qualsiasi direzione Double bank adjustable louvers to send

Dettagli

"SANTANA" UNITÀ A/C A TETTO ROOF TOP A/C UNIT - CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS - CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR

SANTANA UNITÀ A/C A TETTO ROOF TOP A/C UNIT - CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS - CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR "SANTANA" UNITÀ A/C A TETTO ROOF TOP A/C UNIT - CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS - CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR DELPHI ITALIA AUTOMOTIVE SYSTEMS S.r.l. "Stabilimento

Dettagli

SISTEMI FUMARI FLUE SYSTEMS

SISTEMI FUMARI FLUE SYSTEMS SISTEMI FUMARI FLUE SYSTEMS SCHEMA DI MONTAGGIO La THEMA INOX, con questo strumento, cerca di fornire all utilizzatore del proprio prodotto un supporto conforme alle recenti normative in materia, cercando

Dettagli

ventilatori centrifughi cassonati unità di trattamento aria - accessori centrifugal fans in box caissons air treatment unit - equipment

ventilatori centrifughi cassonati unità di trattamento aria - accessori centrifugal fans in box caissons air treatment unit - equipment ventilatori centrifughi cassonati unità di trattamento aria - accessori centrifugal fans in box caissons air treatment unit - equipment ventilatori centrifughi e cassonati doppia aspirazione direttamente

Dettagli

ecopower since 2010 contemporary

ecopower since 2010 contemporary ecopower since 2010 vasca bathtub doccia shower lavabo - bidet washbasin - bidet Design lineare, essenziale e puro per una linea di rubinetti dall anima ecologica. Eco e Power consentono di risparmiare

Dettagli

SCHEDA TECNICA DUPLEX EC.UI 175 Cod. 1300002 ORIZZONTALE DUPLEX EC.UI 175 Cod. 1301002 - VERTICALE

SCHEDA TECNICA DUPLEX EC.UI 175 Cod. 1300002 ORIZZONTALE DUPLEX EC.UI 175 Cod. 1301002 - VERTICALE SCHEDA TECNICA DUPLEX EC.UI 175 Cod. 1300002 ORIZZONTALE DUPLEX EC.UI 175 Cod. 1301002 - VERTICALE RECUPERATORE ORIZZONTALE VERTICALE A RECUPERO TOTALE (scambiatore in Carta) DA 1.580 m³/h DESCRIZIONE

Dettagli

SOLUZIONI ENERGETICHE CON POMPA DI CALORE

SOLUZIONI ENERGETICHE CON POMPA DI CALORE SOLUZIONI ENERGETICHE CON POMPE DI CALORE 28 29 SOLUZIONI ENERGETICHE CON POMPE DI CALORE Pompa di calore per sanitario BOLLITORE 120/150 litri CON POMPA DI CALORE Pompa di calore Eldom GREEN LINE con

Dettagli

Chiudiporta nascosto a camma 900 Concealed cam door closer 900. ASSA ABLOY, the global leader in door opening solutions

Chiudiporta nascosto a camma 900 Concealed cam door closer 900. ASSA ABLOY, the global leader in door opening solutions Chiudiporta nascosto a camma 900 Concealed cam door closer 900 ASSA ABLOY, the global leader in door opening solutions Chiudiporta nascosto con movimento a camma, per porte a battente In-door concealed

Dettagli

ITALTRONIC CBOX CBOX

ITALTRONIC CBOX CBOX 61 Contenitori per la Building Automation Materiale: PC/ABS autoestinguente Colore: Grigio scuro È un nuovo sistema PER L EQUIPAGGIAMENTO DI APPARECCHIATURE ELETTRONICHE su scatole elettriche a parete

Dettagli

Banchi aspiranti. Art. 90.215 BANCO ASPIRANTE AD 1 POSTO POLISHING BENCH SINGLE-SEATER

Banchi aspiranti. Art. 90.215 BANCO ASPIRANTE AD 1 POSTO POLISHING BENCH SINGLE-SEATER Art. 90.215 BANCO ASPIRANTE AD 1 POSTO POLISHING BENCH SINGLE-SEATER Dimensioni: Profondità cm 48 - Larghezza cm 80 - Altezza cm 87 Potenza aspiratore: Hp 0,13 Lamiera d'acciaio verniciata, colore grigio,

Dettagli

Guida all installazione del prodotto 4600 in configurazione plip

Guida all installazione del prodotto 4600 in configurazione plip Guida all installazione del prodotto 4600 in configurazione plip Premessa Questo prodotto è stato pensato e progettato, per poter essere installato, sia sulle vetture provviste di piattaforma CAN che su

Dettagli

Freni idraulici multidisco serie F Hydraulic Multidisc Brakes F Series

Freni idraulici multidisco serie F Hydraulic Multidisc Brakes F Series HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Via M.L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415 730 INTERNET: http://www.hansatmp.it E-MAIL:

Dettagli

Generalità Main Features

Generalità Main Features Generalità Componenti e caratteristiche principali Certificazioni Limiti di funzionamento Dimensioni versioni 2 e tubi Caratteristiche tecniche nominali versione 2 tubi alla massima velocità Caratteristiche

Dettagli

/ < " DI MANAGEMENT C RTI ICA ISTEM )3/ )3/ ä - "

/ <  DI MANAGEMENT C RTI ICA ISTEM )3/ )3/ ä - 64B ATTUATORE ELETTRICO - ELECTRIC ACTUATOR VERSIONE STANDARD 0-90 ( 0-180 - 0-270 ) STANDARD VERSION 0-90 (ON REQUEST 0-180 - 0-270 ) 110V AC 220V AC 100-240 AC CODICE - CODE 85H10001 85H20001 85H00003

Dettagli

pressostati pressure switches

pressostati pressure switches CODICI DI ORDINAZIONE - ORDER CODES NC [NC] NA [NO] 17.005.0 17.004.0 Corpo: ottone OT 58 0.5 bar 0.05 MPa 48V AC Body: brass OT 58 17.007.0 IP 54 17.008.0 4 CODICE DI ORDINAZIONE - ORDER CODE NC-NA [NC-NO]

Dettagli

Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans

Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans SRIZION GNRL La serie rappresenta una soluzione semplice ed economica per l installazione di ventilatori

Dettagli

HERCULES 32 kw 120 l. Caldaie a basamento, a camera stagna e tiraggio forzato con Boiler in acciaio Inox da 120 litri

HERCULES 32 kw 120 l. Caldaie a basamento, a camera stagna e tiraggio forzato con Boiler in acciaio Inox da 120 litri 80 HERCULES 32 kw 120 l Caldaie a basamento, a camera stagna e tiraggio forzato con Boiler in acciaio Inox da 120 litri VANTAGGI ELEGANZA & DESIGN Il cruscotto di HERCULES 32 kw 120 l offre una costante

Dettagli

Attuatore a relè Manuale di istruzioni

Attuatore a relè Manuale di istruzioni Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per

Dettagli

ARES Condensing 32 Caldaia a basamento, a condensazione, per solo riscaldamento

ARES Condensing 32 Caldaia a basamento, a condensazione, per solo riscaldamento 66 ARES Condensing 32 Caldaia a basamento, a condensazione, per solo riscaldamento VANTAGGI E CARATTERISTICHE GENERALI PREDISPOSTA PER FUNZIONAMENTO INDIPENDENTE O IN CASCATA ARES Condensing 32 può essere

Dettagli

Unità canalizzabili da 7,14 kw a 65,80 kw Ductable units from 7,14 kw to 65,80 kw Vers.01/2018 EC INVERTER

Unità canalizzabili da 7,14 kw a 65,80 kw Ductable units from 7,14 kw to 65,80 kw Vers.01/2018 EC INVERTER Unità canalizzabili da 7,14 kw a 65,80 kw Ductable units from 7,14 kw to 65,80 kw Vers.01/2018 EC INVERTER 1 CARATTERISTICHE GENERALI Le unità terminali di trattamento aria a moduli componibili mod. DAT

Dettagli

CONTROL FAN SYSTEM VENTILATORI BLOWERS. Sistemi di controllo Control Systems SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM

CONTROL FAN SYSTEM VENTILATORI BLOWERS. Sistemi di controllo Control Systems SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM CONTROL FAN SYSTEM SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM APPLICAZIONI: Il Control Fan è un sistema di regolazione della velocità utilizzato come controllo a frequenza variabile

Dettagli

ARCHITETTURA DEL SISTEMA

ARCHITETTURA DEL SISTEMA SISTEMI HEATING ARCHITETTURA DEL SISTEMA SISTEMA SPLIT ARIA-ACQUA CARRIER PRESENTA XP ENERGY,, L INNOVATIVA SOLUZIONE DI RISCALDAMENTO E CONDIZIONAMENTO PER APPLICAZIONI RESIDENZIALI CON SISTEMA SPLIT

Dettagli

Integrated Comfort SyStemS

Integrated Comfort SyStemS Integrated Comfort Systems EST (Energy Saving Technology) è una tecnologia applicata ai ventilconvettori e cassette EURAPO che consente di ottenere assorbimenti elettrici estremamente contenuti e una modulazione

Dettagli

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s Caratteristiche generali Mean features Lampade a bassa tensione (24Vcc) Lamps

Dettagli

LA SOLUZIONE PER I VOSTRI PROBLEMI

LA SOLUZIONE PER I VOSTRI PROBLEMI Conservatori serie MULTIPLUS I MULTIPLUS sono impianti studiati e realizzati da ACF per soddisfare l esigenza di quegli operatori che desiderino effettuare sia il ciclo di abbattimento-surgelazione sia

Dettagli

100% 100% elettrici 100% rispetto. 0% fumi gas di scarico 0% rumore. pannelli radianti surya eccezionali per l essiccazione

100% 100% elettrici 100% rispetto. 0% fumi gas di scarico 0% rumore. pannelli radianti surya eccezionali per l essiccazione pannelli radianti surya eccezionali per l essiccazione 100% già predisposti per cabine vecchie e nuove 100% elettrici 100% rispetto dell ambiente 0% fumi gas di scarico 0% rumore RIDUZIONE dei TEMPI di

Dettagli

IL FANCOIL MURALE THE HIGH WALL FANCOIL

IL FANCOIL MURALE THE HIGH WALL FANCOIL IL FANCOIL MURALE FILOMURO IL FANCOIL MURALE ADATTO A TUTTI GLI AMBIENTI TERMINALI AD ACQUA INSTALLATI IN ALTO A MURO PROFONDITÀ ESTREMAMENTE RIDOTTA FOR ANY TYPE OF AMBIENT HIGH WALL WATER COOLED TERMINALS

Dettagli

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES Mod VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES Mod VS/AM 65 1 2 VS/AM 65 STANDARD VS/AM 65 CON RACCORDI VS/AM 65

Dettagli

SCATTER Caratteristiche generali General features

SCATTER Caratteristiche generali General features 141 Caratteristiche generali General features I destratificatori elicoidali serie scatter, sono adatti a distribuire, nella stagione invernale, volumi d aria in medi e grandi ambienti, come capannoni,

Dettagli

Costruzioni Constructions. Acustica Acoustics 0109/DC/ACU/10 26/07/2010

Costruzioni Constructions. Acustica Acoustics 0109/DC/ACU/10 26/07/2010 Costruzioni Constructions Acustica Acoustics 0109/DC/ACU/10 26/07/2010 1 VAWA panel partition + plasterboard lining Veneziani Acell S.r.l. Via delle Groane 126 I-20024 Garbagnate Milanese (MI) UNI EN ISO

Dettagli

ANODIZING EXCHANGE UNIT AND TEMPERATURE CONTROL

ANODIZING EXCHANGE UNIT AND TEMPERATURE CONTROL Scheda Tecnica / Technical sheet GRUPPO DI SCAMBIO E CONTROLLO TEMPERATURA OSSIDO AND TEMPERATURE CONTROL Per il raffreddamento dei bagni di anodizzazione vengono impiegati particolari gruppi di scambio.

Dettagli

Light Cubic Unit Coolers

Light Cubic Unit Coolers Light Cubic Unit Coolers F E A T U R E S C A R A T T E R I S T I C H E Thermokey presents a new direct expansion unit coolers series designed for small and medium cold rooms for storage of fresh or frozen

Dettagli

Gateway Bacnet Multichiller series

Gateway Bacnet Multichiller series Servizio egolazione e Controllo File Pagina 1/11 Gateway Bacnet Multichiller series Servizio egolazione e Controllo File Pagina 2/11 CONTENTS 1. PCOWEB INSTALLATION... 3 2. BACNET MAPPING... 5 3. PCO COMMUNICATION

Dettagli

2011 New Split Inverter

2011 New Split Inverter 2011 New Split Inverter LT/LU series FUJITSU GENERAL LIMITED Design: lineare Serie High COP & Powerful heating model LT serie High COP model LU serie Capacità Elevate prestazioni & Risparmio energetico

Dettagli

Esempi d installazione

Esempi d installazione Esempi d installazione Examples of installation Multi INVERTER 1 h + 2 3-4 istanze fra le unità istance between units Modelli Models islivello massimo tra le unità Interne Max distance between Indoor units

Dettagli

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES CARATTERISTICHE GENERALI: Le valvole nella versione standard sono normalmente aperte. Il coperchio ed il corpo valvola sono in ghisa. La membrana

Dettagli

Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans

Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans Conformi alla Direttiva ErP e al regolamento E 1253/214 (nità di ventilazione non residenziale) Categoria

Dettagli

AR200 AR200. Porta a lama d'aria da incasso per piccoli ingressi

AR200 AR200. Porta a lama d'aria da incasso per piccoli ingressi AR00 Porta a lama d'aria da incasso per piccoli ingressi Altezza di installazione consigliata,5 m* Montaggio incassato Lunghezze:,,5 e m Solo ventilazione, senza riscaldamento Riscaldamento elettrico:

Dettagli

Componenti - Components 03

Componenti - Components 03 SERIE LR25 SERIES Lanterne ventilate Cooled bellhousings Componenti - Components 03 Con il fine di migliorare costantemente la qualità dei nostri prodotti, ci riserviamo il diritto di modificarne in qualsiasi

Dettagli

SCHEDA TECNICA LAVATRICI RC/LS IM8 TECHNICAL DATA SHEET IM8 RC/LS WASHING MACHINES

SCHEDA TECNICA LAVATRICI RC/LS IM8 TECHNICAL DATA SHEET IM8 RC/LS WASHING MACHINES SCHEDA TECNICA LAVATRICI RC/LS IM8 TECHNICAL DATA SHEET IM8 RC/LS WASHING MACHINES MODELLO MODEL CAPACITA CAPACITY DIAMETRO CESTO DRUM DIAMETER PROFONDITA CESTO DRUM DEPTH DIAMETRO DI CARICO LOAD DIAMETER

Dettagli

ENERBOX ENERBOX. SEGNALAZIONI Grazie al GSM integrato, in caso di black-out od anomalie, Enerbox invia

ENERBOX ENERBOX. SEGNALAZIONI Grazie al GSM integrato, in caso di black-out od anomalie, Enerbox invia ENERBOX ENERBOX COS È ENERBOX è un inverter di tensione che converte la bassa tensione delle batterie in tensione monofase 230V alternata e stabilizzata. In presenza di rete o fonte d energia alternativa,

Dettagli

URE UNITA DI RECUPERO DI CALORE. 8 grandezze per portate d aria da 290 a 4000 m3/h

URE UNITA DI RECUPERO DI CALORE. 8 grandezze per portate d aria da 290 a 4000 m3/h URE UNITA DI RECUPERO DI CALORE 8 grandezze per portate d aria da 290 a 4000 m3/h Le unità di recupero di calore serie URE sono state studiate per effettuare un ricambio d aria forzato con recupero di

Dettagli

filtro separatore G1 G1 filter-water-separator

filtro separatore G1 G1 filter-water-separator filtro separatore filter-water-separator Sistema di funzionamento: gruppo ciclone ed elemento filtrante Cyclone system and filter element Separazione condensa: 96% Moisture separation: 96% Scarico della

Dettagli

UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998

UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998 COSTRUZIONI FISICA TECNICA/ACUSTICA 1/6 ECOstrong Slalom Via Ernesto Rossi, 69 20862 Arcore (MB) UNI EN ISO 354 :2003 UNI EN ISO 11654 :1998 Slalom Capo Laboratorio Laboratory Head 2/6 DATI GENERALI /

Dettagli

POMPA A MANO MODULARE DI EMERGENZA

POMPA A MANO MODULARE DI EMERGENZA POMPA A MANO MODULARE DI EMERGENZA EMERGENCY MODULAR HAND PUMP Codice / Code -0-0077 Codice / Code -0-00708 Ingombro / Dimensions -0-0077 CARATTERISTICHE TECNICHE Cilindrata 6 cm Pressione esercizio Pressione

Dettagli