1 STUDIO GEOLOGICO AMBIENTALE DOTT. MAURIZIO CASTELLARI Via Mascagni Imola BO Tel. 0542/ cell. 334/ RELAZIONE SULL INDAGINE GEOLOGICA E GEOTECNICA ESEGUITA PER LA NUOVA COSTRUZIONE DI UN IMPIANTO ASCENSORE E DELLE OPERE ESTERNE NELL AMBITO DEI LAVORI DI RIQUALIFICAZIONE DELLA SALA G.MICETI E ADEGUAMENTO FUNZIONALE DEI LOCALI PER LA REALIZZAZIONE DI INFO POINT. Committente: Beni Comuni S.r.l. Via Poiano Imola Imola 13 dicembre 15 Dott. Maurizio Castellari Via Mascagni Imola (BO) Tel mail: castellari.geo@gmail.com P. Iva C. F. CSTMRZ60R01E289N 1

2 Sommario 1 PREMESSA GEOLOGIA E GEOMORFOLOGIA PROVE PENETROMETRICHE PROGETTAZIONE GEOTECNICA Approccio 2 fondazioni a platea CARATTERISTICHE EDIFICATORIE CALCOLO DEI CEDIMENTI SISMICITA' DELL' AREA CONCLUSIONI

3 1 PREMESSA Su incarico di BENI COMUNI S.R.L. con sede in Via Poiano, Imola, è stata eseguita un indagine geologica e geotecnica per la nuova costruzione di un impianto ascensore e delle opere esterne nell ambito dei lavori di riqualificazione della sala G.Miceti e adeguamento funzionale dei locali per la realizzazione di info point., come da planimetria allegata, intesa ad accertare alcune caratteristiche geomeccaniche dei terreni su cui dovranno effettuarsi gli interventi previsti dal progetto. Si sono pertanto individuati i tipi litologici ed alcune proprietà dei terreni medesimi, che verranno descritti di seguito. L indagine è stata eseguita direttamente sull area mediante prove penetrometriche statiche ed utilizzando dati di precedenti indagini eseguite in aree limitrofe. In Allegato 1. è indicata l area di intervento. In Allegato 2. sono indicati i punti d esecuzione delle prove penetrometriche. In Allegato 3. sono riportati i diagrammi di resistenza dei terreni. In Allegato 4. è riportata la stratigrafia dell area derivante da un sondaggio eseguito in precedenza In Allegato 5. è riportata l indagine sismica del terreno. 3

4 Figura 1: tavola di progetto 4

5 2 GEOLOGIA E GEOMORFOLOGIA I terreni in posto non sono visibili direttamente; se ne è quindi ricavata la natura mediante l'analisi della resistenza alla punta delle varie prove penetrometriche. Il complesso della Sala Miceti occupa un area al limite meridionale del centro storico di Imola, nell ambito del territorio alluvionale lungo il corso del fiume Santerno, in corrispondenza della fine del suo tratto collinare e dell inizio del tratto di pianura. Da un punto di vista geologico vi è da considerare che il substrato della fascia collinare imolese è costituito da due principali formazioni: le Argille Grigio Azzurre e le Sabbie Gialle. Le Argille Azzurre sono depositi di origine marina accumulatisi all interno di un esteso e profondo bacino a partire dal Pliocene (circa 5 Ma di anni fa), per arrivare fino al Pleistocene inferiore (circa 1 Ma fa). Successivamente, in seguito all abbassamento del livello marino, connesso con l emersione della porzione esterna dell Appennino, la lenta deposizione delle argille è stata sostituita della deposizione di litotipi più grossolani, come sabbie e ciottoli ghiaiosi di ambiente litorale. In questo contesto si ha l inizio di un antica linea di costa del mare Adriatico di cui è costituita principalmente la formazione delle Sabbie Gialle, che ne sono la testimonianza, prima del suo ritiro verso l attuale posizione. La suddetta formazione sabbiosa, i cui affioramenti più prossimi all Osservanza si hanno nella zona del Monte Castellaccio, sovrasta quella argillosa più antica. In una fase successiva, prima comunque della deposizione dei sedimenti alluvionali del Santerno, al di sopra delle Sabbie Gialle si è verificata la messa in posto di un unità costituita da una prevalente componente pelitica informalmente chiamata Gonze 1. Essa, non contemplata attualmente dalla cartografia geologica ufficiale, e che è stata rilevata in affioramento solo in casi molto sporadici e piuttosto isolati (ad esempio presso il ponte sul Santerno vicino all Autodromo), è attribuibile comunque ad un contesto continentale. 1 VAI G.B., Introduzione alla geologia dell Appennino nord-orientale sulle orme di Scartabelli in La collezione Scarabeili. I - Geologia, Gratis Edizioni, 1995

6 Infine, a partire dal Pleistocene medio si è verificata la messa in posto di litotipi alluvionali legati principalmente all azione deposizionale del Santerno, organizzati in strutture tabulari e sub-orizzontali, Questi corpi alluvionali, una volta reincisi dall erosione fluviale, costituiscono veri e propri terrazzi alluvionali disposti su vari livelli, cioè ubicati a diverse quote. Alcuni terrazzi, particolarmente antichi, si possono trovare anche a quote elevate di parecchie decine di metri rispetto all attuale alveo, come si osserva in particolare nella porzione collinare; mentre, man mano che ci si avvicina alla pianura prevalgono terrazzi più recenti e poco elevati. Si verifica in sostanza che all altezza del Centro Storico di Imola risulta sempre più difficoltosa una distinzione netta tra i vari terrazzamenti fluviali, ulteriormente complicata dal fatto che essi sono anche stati livellati da successivi rialluvonamenti del Santerno che si riportava ciclicamente alla stessa quota, così da simulare una sola forma terrazzata, capace di generare false interpretazioni a livello di stratigrafia di dettaglio Da un punto di vista litologico i terrazzi sono caratterizzati da una certa variabilità granulometrica, da grossolana (ghiaie e sabbie) a fine (limi ed argille) differenziatesi secondo l alternanza dei periodi climatici (freddi e caldi o piovosi e asciutti) e della velocità di sollevamento della catena appenninica 2, Per completare il quadro geologico generale è infine da tener conto che, allo sbocco nella pianura, il Santerno, depositando il proprio carico di sedimenti in funzione della propria energia, ha costituito un ampio conoide di deiezione, dalla tipica forma a ventaglio e dovuto alla progressiva perdita di energia da parte del corso d acqua stesso, entro il quale si interdigitano peraltro i terrazzi presenti alle quote più basse. Nell estremo settore NE del territorio comunale imolese, esternamente alla frangia del conoide, sono presenti depositi di piana alluvionale la cui natura granulometrica risulta essere formata, perlopiù, da depositi fini e molto fini (sabbie limose, limi, argille limose e torbe). Da un punto di vista geomorfologico, le suddette Formazioni e unità alluvionali hanno una risposta assai differenziata. Ad esempio la formazione pliocenica delle Argille Grigio- Azzurre risulta essenzialmente distinguibile per la presenza sui versanti di tipiche forme franose e calanchive, che generano un particolare assetto nel territorio; mentre la 2 Marabini, Introduzione alla geologia dell imolese in Archeologia del territorio nell Imolese, 1994.

7 formazione delle Sabbie Gialle determina rilievi meno regolari e scarpate molto più ripide in virtù della propria natura litologica, maggiormente competente e coesiva. Al contrario, le aree occupate dai terrazzi e dai conoidi sono perlopiù caratterizzate da superfici suborizzontali o leggermente degradanti verso le quote inferiori della bassa pianura alluvionale, risultando pertanto esenti da fenomeni erosivi imputabili all attività geodinamica gravitativa. Entrando in un maggior dettaglio si può concludere che l area della Sala Miceti si estende al di sopra di terreni di origine esclusivamente continentale, riferibili ai depositi alluvionali terrazzati del fiume Santerno che ricoprono un substrato profondo costituito superiormente dalla formazione delle Sabbie Gialle. L area si sviluppa su una superficie praticamente orizzontale, e pertanto risulta esente dalla presenza di movimenti geodinamici gravitativi. Le indagini geognostiche realizzate hanno permesso, in particolare, di distinguere sull area in superficie tre unità litostratigrafiche principali corrispondenti ad altrettanti ordini di terrazzo, relativi al fiume Santerno. Sulla base delle osservazioni condotte in merito all evoluzione dei suoli superficiali e alla natura del materiale alluvionale ghiaioso, si è anche proceduto ad un ipotesi di attribuzione cronologica delle tre unità, potenzialmente utile anche in termini geotecnici. In pratica, l origine dell unità più recente A III ordine può essere ricondotta attorno al periodo tardo-medievale; l unità intermedia B II ordine risale probabilmente ad un periodo compreso tra l epoca romana ed il primo medioevo; infine, l unità più antica C I ordine è sicuramente di formazione precedente al periodo romano. Queste tre unità, benché formatesi in tempi differenti, risultano generalmente affiancate e solo parzialmente sovrapposte, in quanto la progressiva migrazione verso Est dell alveo del fiume Santerno, unitamente ai ciclici abbassamenti del livello di base dell erosione e fenomeni di rialluvionamento, ha consentito solo una parziale erosione dei materassi alluvionali per opera del corso d acqua. L'idrologia superficiale è regimata da regolare fognatura e per quanto riguarda gli acquiferi sotterranei nel corso dell'esecuzione delle prove penetrometriche si è rinvenuta la presenza di un acquifero a pelo libero alla profondità di 7,5 m dal piano campagna.

8 Sala Miceti Figura 2 Carta geologica dell area tratta dalla Cartografia geologica della Regione Emilia Romagna

9 Le caratteristiche dell area di studio la situano nella piana alluvionale del fiume Santerno nell Unità AES8 sub sistema di Ravenna. 3 PROVE PENETROMETRICHE Date le presumibili caratteristiche stratigrafiche del sottosuolo, già indagato in aree contermini, sull'area sono state eseguite n 3 prove penetrometriche dinamiche leggere atta a porre in evidenza alcune caratteristiche meccaniche dei terreni e la presenza e profondità della falda freatica. Sono stati inoltre reperiti i log stratigrafici di due sondaggi a rotazione eseguiti nelle vicinanze del insediamento che hanno dato indicazioni sulla stratigrafia dell area. Le quote sono riferite al piano di campagna e l'ubicazione della prova viene riportata nella planimetria allegata ed indicata con un cerchio pieno e numerazione progressiva. Per l'esecuzione delle prove penetrometriche statiche è stato utilizzato un penetrometro olandese tipo "GOUDA" della Ditta "Pagani" di Piacenza, da ton 20, pari a kn 200, di potenza di spinta, con punta meccanica e manicotto laterale di attrito tipo "Begemann". Le dimensioni della punta sono quelle dello Standard europeo:

10 - diametro: mm 35,7; - angolo di apertura: 60 ; - area punta: cm2 10; - diametro manicotto: mm 35,7; - lunghezza manicotto: mm 133; - Friction Area: cm2 150; - velocità di avanzamento costante cm/sec 2,0. Durante l'esecuzione delle prove vengono misurate la resistenza alla punta Rp (kg/cm2) e l'attrito al manicotto laterale Rl (kg/cm2). L'esame dei diagrammi della resistenza statica evidenzia una discreta omogeneità in senso orizzontale dei valori, correlabile ad uniformità litologica e/o di grado di addensamento dei terreni indagati ed andamento lenticolare in senso verticale. Le prove evidenziano la presenza di terreni con resistenza statica decrescente progressivamente, da buona a discreta a fino a circa m 8 9 di profondità dal piano di campagna; a tali quote inizia un banco di ghiaia e ghiaia sabbiosa sul quale le prove sono andate a rifiuto. L'esame dei grafici evidenzia un eterogeneità dei dati di resistenza alla penetrazione in senso verticale, in conseguenza di eterogeneità litologica; i terreni evidenziano andamento non compara bile fra le prove, anche a modesta distanza, fino alla profondità d i m.3 e permettono di ipotizzare presenza di ripor to fino alla suddetta profondità. Nelle due prove eseguite si è rinvenuta la presenza di acqua alla profondità ci circa 7,5 m. 4 PROGETTAZIONE GEOTECNICA Estratto dal D.M. 14/01/2008 recante "Norme tecniche per le costruzioni" PRESCRIZIONI GENERALI Le scelte progettuali devono tener conto delle prestazioni attese delle opere, dei caratteri geologici del sito e delle condizioni ambientali.

11 I risultati dello studio rivolto alla caratterizzazione e modellazione geologica, di cui al devono essere esposti in una specifica relazione geologica. Le analisi di progetto devono essere basate su modelli geotecnici dedotti da specifiche indagini e prove che il progettista deve definire in base alle scelte tipologiche dell opera o dell intervento e alle previste modalità esecutive. Le scelte progettuali, il programma e i risultati delle indagini, la caratterizzazione e la modellazione geotecnica, di cui al 6.2.2, unitamente ai calcoli per il dimensionamento geotecnico delle opere e alla descrizione delle fasi e modalità costruttive, devono essere illustrati in una specifica relazione geotecnica CARATTERIZZAZIONE E MODELLAZIONE GEOLOGICA DEL SITO La caratterizzazione e la modellazione geologica del sito consiste nella ricostruzione dei caratteri litologici, stratigrafici, strutturali, idrogeologici, geomorfologici e, più in generale, di pericolosità geologica del territorio. In funzione del tipo di opera o di intervento e della complessità del contesto geologico, specifiche indagini saranno finalizzate alla documentata ricostruzione del modello geologico. Esso deve essere sviluppato in modo da costituire utile elemento di riferimento per il progettista per inquadrare i problemi geotecnici e per definire il programma delle indagini geotecniche. Metodi e risultati delle indagini devono essere esaurientemente esposti e commentati in una relazione geologica INDAGINI, CARATTERIZZAZIONE E MODELLAZIONE GEOTECNICA Le indagini geotecniche devono essere programmate in funzione del tipo di opera e/o di intervento e devono riguardare il volume significativo di cui al 3.2.2, e devono permettere la definizione dei modelli geotecnici di sottosuolo necessari alla progettazione. I valori caratteristici delle grandezze fisiche e meccaniche da attribuire ai terreni devono essere ottenuti mediante specifiche prove di laboratorio su campioni indisturbati di terreno e attraverso l interpretazione dei risultati di prove e misure in sito. Per valore caratteristico di un parametro geotecnico deve intendersi una stima ragionata e cautelativa del valore del parametro nello stato limite considerato. Per modello geotecnico si intende uno schema rappresentativo delle condizioni stratigrafiche, del regime delle pressioni interstiziali e della caratterizzazione fisico-meccanica dei terreni e delle rocce comprese nel volume significativo, finalizzato all analisi quantitativa di uno specifico problema geotecnico. È responsabilità del progettista la definizione del piano delle indagini, la caratterizzazione e la modellazione geotecnica...

12 Nel caso di costruzioni o di interventi di modesta rilevanza, che ricadano in zone ben conosciute dal punto di vista geotecnico, la progettazione può essere basata sull esperienza e sulle conoscenze disponibili, ferma restando la piena responsabilità del progettista su ipotesi e scelte progettuali VERIFICHE DELLA SICUREZZA E DELLE PRESTAZIONI Le verifiche di sicurezza relative agli stati limite ultimi (SLU) e le analisi relative alle condizioni di esercizio (SLE) devono essere effettuate nel rispetto dei principi e delle procedure seguenti Verifiche nei confronti degli stati limite ultimi (SLU) Per ogni stato limite ultimo deve essere rispettata la condizione Ed Rd (6.2.1) dove Ed è il valore di progetto dell azione o dell effetto dell azione ovvero con ge = gf, e dove Rd è il valore di progetto della resistenza del sistema geotecnico: Effetto delle azioni e resistenza sono espresse in funzione delle azioni di progetto gffk, dei parametri di progetto Xk/gM e della geometria di progetto ad. L effetto delle azioni può anche essere valutato direttamente come Ed=Ek ge. Nella formulazione della resistenza Rd, compare esplicitamente un coefficiente gr che opera direttamente sulla resistenza del sistema. La verifica della suddetta condizione deve essere effettuata impiegando diverse combinazioni di gruppi di coefficienti parziali, rispettivamente definiti per le azioni (A1 e A2), per i parametri geotecnici (M1 e M2) e per le resistenze (R1, R2 e R3). I diversi gruppi di coefficienti di sicurezza parziali sono scelti nell ambito di due approcci progettuali distinti e alternativi. Nel primo approccio progettuale (Approccio 1) sono previste due diverse combinazioni di gruppi di coefficienti: la prima combinazione è generalmente più severa nei confronti del dimensionamento strutturale

13 delle opere a contatto con il terreno, mentre la seconda combinazione è generalmente più severa nei riguardi del dimensionamento geotecnico. Nel secondo approccio progettuale (Approccio 2) è prevista un unica combinazione di gruppi di coefficienti, da adottare sia nelle verifiche strutturali sia nelle verifiche geotecniche. 4.1 Approccio 2 fondazioni a platea DATI GENERALI ====================================================== Azione sismica NTC 2008 Zona Via Bernarda 1650 CSPT Lat./ Long. [WGS84] 44,400099/11,62621 Larghezza fondazione 2,0 m Lunghezza fondazione 3,5 m Profondità piano di posa 1,5 m Altezza di incastro 1,5 m Profondità falda 7,5 ====================================================== SISMA ====================================================== Accelerazione massima (ag/g) 0,095 Effetto sismico secondo NTC(C ) Fattore di struttura [q] 1,5 Periodo fondamentale vibrazione [T] 0,474 Coefficiente intensità sismico terreno [Khk] 0,019 Coefficiente intensità sismico struttura [Khi] 0,2305 ====================================================== Coefficienti sismici [N.T.C.] ======================================================================== Dati generali Tipo opera: 2 - Opere ordinarie Classe d'uso: Classe II Vita nominale: 50,0 [anni] Vita di riferimento: 50,0 [anni] Parametri sismici su sito di riferimento Categoria sottosuolo: Categoria topografica: C T1 S.L. Stato limite TR Tempo ritorno [anni] ag [m/s²] F0 [-] TC* [sec] S.L.O. 30,0 0,62 2,43 0,26 S.L.D. 50,0 0,79 2,41 0,27 S.L.V. 475,0 1,97 2,42 0,3 S.L.C. 975,0 2,48 2,47 0,31 Coefficienti sismici orizzontali e verticali Opera: Stabilità dei pendii e Fondazioni S.L. Stato limite amax [m/s²] beta [-] kh [-] kv [sec] S.L.O. 0,93 0,2 0,019 0,0095 S.L.D. 1,185 0,2 0,0242 0,0121 S.L.V. 2,7743 0,28 0,0792 0,0396 S.L.C. 3,2865 0,28 0,0938 0,0469

14 STRATIGRAFIA TERRENO Spessore strato [m] Peso unità di volume [kn/m³] Peso unità di volume saturo [kn/m³] Angolo di attrito [ ] Coesion e [kn/m²] Coesion e non drenata [kn/m²] Modulo Elastico [kn/m²] Modulo Edometr ico [kn/m²] Poisson Coeff. consolid az. primaria [cmq/s] Coeff. consolid azione secondar ia Descrizi one 3,0 17,65 18,63 25,0 9,81 78,45 0,0 7354,99 0,5 0,003 0,005 riporto 5,0 19,12 20,1 23,0 9,81 68, , ,33 0,5 0,004 0,005 sabbia e limo 4,0 19,12 20,59 36,0 0,0 0, ,2 5 Carichi di progetto agenti sulla fondazione Nr. Nome combinazio ne Pressione normale di progetto N [kn] Mx [kn m] My [kn m] 0,0 0,25 0,0 0,0 sabbia ghiaiosa Hx [kn] Hy [kn] [kn/m²] 1 A1+M1+R3 157,77 0,00 0,00 0,00 0,00 0,00 Progetto 2 Sisma 157,77 0,00 0,00 0,00 0,00 0,00 Progetto 3 S.L.E. 157,77 0,00 0,00 0,00 0,00 0,00 Servizio 4 S.L.D. 157,77 0,00 0,00 0,00 0,00 0,00 Servizio Sisma + Coeff. parziali parametri geotecnici terreno + Resistenze Nr Correzione Sismica Tangente angolo di resistenza al Coesione efficace Coesione non drenata Peso Unità volume in fondazione Peso unità volume copertura Coef. Rid. Capacità portante verticale Tipo Coef.Rid.C apacità portante orizzontale taglio 1 Si ,3 1,1 2 Si ,3 1,1 3 Si Si CARICO LIMITE FONDAZIONE COMBINAZIONE...A1+M1+R3 Autore: Brinch - Hansen 1970 Carico limite [Qult] 473,3 kn/m² Resistenza di progetto[rd] 205,78 kn/m² Tensione [Ed] 157,77 kn/m² Fattore sicurezza [Fs=Qult/Ed] 3,0 Condizione di verifica [Ed<=Rd] Verificata COEFFICIENTE DI SOTTOFONDAZIONE BOWLES (1982) Costante di Winkler 18931,99 kn/m³ A1+M1+R3 Autore: Brinch - Hansen 1970 (Condizione non drenata) ====================================================== Fattore [Nq] 1,0 Fattore [Nc] 5,14 Fattore [Ng] 0,0 Fattore forma [Sc] 1,11 Fattore profondità [Dc] 1,0 Fattore inclinazione carichi [Ic] 1,0 Fattore inclinazione pendio [Gc] 1,0 Fattore inclinazione base [Bc] 1,0 Fattore correzione sismico inerziale [zq] 1,0 Fattore correzione sismico inerziale [zg] 1,0 Fattore correzione sismico inerziale [zc] 1,0

15 ====================================================== Carico limite 473,3 kn/m² Resistenza di progetto 205,78 kn/m² Condizione di verifica [Ed<=Rd] Verificata ====================================================== Sisma Autore: Brinch - Hansen 1970 (Condizione non drenata) ====================================================== Fattore [Nq] 1,0 Fattore [Nc] 5,14 Fattore [Ng] 0,0 Fattore forma [Sc] 1,11 Fattore profondità [Dc] 1,0 Fattore inclinazione carichi [Ic] 1,0 Fattore inclinazione pendio [Gc] 1,0 Fattore inclinazione base [Bc] 1,0 Fattore correzione sismico inerziale [zq] 1,0 Fattore correzione sismico inerziale [zg] 1,0 Fattore correzione sismico inerziale [zc] 1,0 ====================================================== Carico limite 473,3 kn/m² Resistenza di progetto 205,78 kn/m² Condizione di verifica [Ed<=Rd] Verificata ====================================================== CEDIMENTI PER OGNI STRATO *Cedimento edometrico calcolato con: Metodo consolidazione monodimensionale di Terzaghi Pressione normale di progetto 80,0 kn/m² Cedimento dopo T anni 10,0 Cedimento totale 1,9 cm Z: Profondità media dello strato; Dp: Incremento di tensione; Wc: Cedimento consolidazione; Ws:Cedimento secondario; Wt: Cedimento totale. Strato Z (m) Tensione (kn/m²) Dp (kn/m²) Metodo Wc (cm) Ws (cm) Wt (cm) 1 2,25 39,713 47,197 Edometrico 0, ,96 2 5,5 100,75 9,244 Edometrico 0, , Schmertmann Decorso cedimenti nel tempo Strato..1 Wt=0,96 cm Cedimento [cm] % Ced Tempo giorni 0, , , , , , , ,75 0, , , , , ,9306 0, ,875 0, ,4444 0, ,2222

16 Decorso cedimenti nel tempo Strato..2 Wt=0,94 cm Cedimento [cm] % Ced Tempo giorni 0, , , , , , , , , ,7824 0, ,8866 0, ,522 0, ,1562 0, ,4259 0, ,3796 Figura 2 Stratigrafia Area Borghetto

17 5 CARATTERISTICHE EDIFICATORIE Come risulta dall elaborato grafico allegato, le penetrometrie sono state ubicate in maniera da investigare tutta la superficie delle aree in cui si eseguiranno gli interventi più significativi. Sulla base di quanto sopra riportato, dei calcoli effettuati per le verifiche di sicurezza relative agli stati limite ultimi (SLU) e della natura dei terreni, il terreno non alterato sottostante il materiale di riporto può sopportare resistenza di progetto secondo l approccio 2 pari a di 2 d.a.n./cm 2 ed occasionale dinamica di 2.4 d.a.n./cm 2. Si possono eseguire fondazioni a platea alla profondità di 1,5 m dal piano campagna per i due vani scala ed il vano ascensori Le ghiaie sulle quali si sono fermate le prove penetrometriche hanno un angolo di attrito interno di ed un peso per unità di volume pari a circa 1950 kg/m 3. Dalle prove penetrometriche effettuate non è risultata la presenza di strati di sabbia pulita e satura e ciò unito al facile drenaggio delle acque attraverso lo strato ghiaioso sottostante, permette di escludere la liquefazione dei terreni medesimi in presenza di evento sismico.

18 6 CALCOLO DEI CEDIMENTI Pur avendo calcolato una resistenza di progetto che nell approccio 2 è di 205,78 kn/m 2 per calcolare i cedimenti e mantenerli all interno di un range compatibile con gli interventi in progetto di un si è utilizzata la tensione normale di progetto pari a 70,0 kn/m² secondo quanto riportato di seguito CEDIMENTI PER OGNI STRATO *Cedimento edometrico calcolato con: Metodo consolidazione monodimensionale di Terzaghi Pressione normale di progetto 70,0 kn/m² Cedimento dopo T anni 10,0 Cedimento totale 1,55 cm Z: Profondità media dello strato; Dp: Incremento di tensione; Wc: Cedimento consolidazione; Ws:Cedimento secondario; Wt: Cedimento totale. Strato Z (m) Tensione (kn/m²) Dp (kn/m²) Metodo Wc (cm) Ws (cm) Wt (cm) 1 2,25 39,713 38,379 Edometrico 0, ,78 2 5,5 100,75 7,517 Edometrico 0, , Schmertmann Decorso cedimenti nel tempo Strato..1 Wt=0,78 cm Cedimento [cm] % Ced Tempo giorni 0, , , , , , , ,75 0, , , , , ,9306 0, ,875 0, ,4444 0, ,2222 Decorso cedimenti nel tempo Strato..2 Wt=0,77 cm Cedimento [cm] % Ced Tempo giorni 0, , , , , , , , , ,7824 0, ,8866 0, ,522 0, ,1562 0, ,4259 0, ,3796

19 7 SISMICITA' DELL' AREA In base alla normativa riguardante la situazione sismica del territorio, con riferimento al D.M. Min. LLPP 16 Gennaio 1996 "Norme tecniche per le costruzioni in zone sismiche", il Comune di Imola, ricadeva in una zona classificata in classe II. Nel mese di Marzo 2003 è stata redatta una bozza al fine di definire un sistema normativo per la progettazione antisismica e acquisire dei criteri generali per la classificazione sismica del territorio nazionale. In riferimento a tale bozza il Comune di Imola ricade in classe 2, indicativa di zona a media pericolosità sismica. Con l'entrata in vigore, il 24/10/2005, dell'opcm n. 3274/2003 e successive modifiche, in materia di classificazione sismica del territorio nazionale e del D.M. 14/09/2005 recante "Norme tecniche per le costruzioni", il Comune di Imola è stato classificato in classe di sismicità 2 (zona a media sismicità) e presenta pertanto un coefficiente di accelerazione orizzontale massima su suolo di categoria A, pari ad ag = 0.25 g. Estratto dal D.M. 14/01/2008 recante "Norme tecniche per le costruzioni" 3.2 AZIONE SISMICA CATEGORIE DI SOTTOSUOLO E CONDIZIONI TOPOGRAFICHE Categorie di sottosuolo Ai fini della definizione dell azione sismica di progetto, si rende necessario valutare l effetto della risposta sismica locale mediante specifiche analisi, come indicato nel In assenza di tali analisi, per la definizione dell azione sismica si può fare riferimento a un approccio semplificato, che si basa sull individuazione di categorie di sottosuolo di riferimento (Tab. 3.2.II e 3.2.III).

20 Per sottosuoli appartenenti alle ulteriori categorie S1 ed S2 di seguito indicate (Tab. 3.2.III), è necessario predisporre specifiche analisi per la definizione delle azioni sismiche, particolarmente nei casi in cui la presenza di terreni suscettibili di liquefazione e/o di argille d elevata sensitività possa comportare fenomeni di collasso del terreno. Nelle definizioni precedenti Vs30 è la velocità media di propagazione entro 30 m di profondità delle onde di taglio e viene calcolata con la seguente espressione: dove hi e Vi indicano lo spessore (in m) e la velocità delle onde di taglio (per deformazioni di taglio γ < 10-6) dello strato iesimo, per un totale di N strati presenti nei 30 m superiori.il sito verrà classificato sulla base del valore di Vs30, se disponibile, altrimenti sulla base del valore di NSPT.

21 Ai fini della caratterizzazione sismica del sottosuolo, l indagine geofisica con apparecchio tromografico digitale TROMINO, avvalendosi del metodo di Nakamura sul rapporto spettrale H/, fornisce una valutazione diretta della Vs 30 in base all individuazione delle discontinuità sismiche e della profondità della formazione rocciosa. A seguire uno schema dei sismostrati nei quali è stato suddiviso il sottosuolo, ciascuno caratterizzato da uno specifico valore Vs, e quindi il relativo grafico dell andamento della Vs in profondità,. Profondità totale [m] Sismostrati [m] Vs [m/s] inf. inf. 540 Il valore medio risultante dall elaborazione fornisce la seguente Vs30, valore che non va assunto come dato certo, ma considerando un margine di errore almeno del 20%. Vs 30 =239m/s 50m/s Il valore ottenuto classifica il terreno come sito C. Trattasi di sabbie e ghiaie mediamente addensate e argille di media consistenza.

22 Nella tabella sotto è illustrata la qualità del segnale acquisito in base al progetto SESAME (Linee guida 2005). Per l affidabilità della curva HVSR devono essere positivi i primi 3 parametri, mentre per avere un chiaro e pulito segnale del picco massimo devono essere soddisfatti 5 parametri su 6. Max. H/V at 0.28 ± 0.01 Hz. (in the range Hz). Criteria for a reliable HVSR curve [All 3 should be fulfilled] f 0 > 10 / L w 0.28 > 0.50 NO n c (f 0 ) > > 200 OK s A (f) < 2 for 0.5f 0 < f < 2f 0 if f 0 > 0.5Hz s A (f) < 3 for 0.5f 0 < f < 2f 0 if f 0 < 0.5Hz Exceeded 0 out of 14 times OK Criteria for a clear HVSR peak [At least 5 out of 6 should be fulfilled] Exists f - in [f 0 /4, f 0 ] A H/V (f - ) < A 0 / Hz OK Exists f + in [f 0, 4f 0 ] A H/V (f + ) < A 0 / Hz OK A 0 > > 2 OK f peak [A H/V (f) ± s A (f)] = f 0 ± 5% < 0.05 OK s f < e(f 0 ) < OK s A (f 0 ) < q(f 0 ) < 2.5 OK L w n w n c = L w n w f 0 f f 0 s f e(f 0 ) A 0 A H/V (f) f f + s A (f) s logh/v (f) q(f 0 ) window length number of windows used in the analysis number of significant cycles current frequency H/V peak frequency standard deviation of H/V peak frequency threshold value for the stability condition f < (f 0 ) H/V peak amplitude at frequency f 0 H/V curve amplitude at frequency f frequency between f 0 /4 and f 0 for which A H/V (f - ) < A 0 /2 frequency between f 0 and 4f 0 for which A H/V (f + ) < A 0 /2 standard deviation of A H/V (f), A (f) is the factor by which the mean A H/V (f) curve should be multiplied or divided standard deviation of log A H/V (f) curve threshold value for the stability condition A (f) < (f 0 ) Threshold values for f and A (f 0 ) Freq.range [Hz] < > 2.0 e(f 0 ) [Hz] 0.25 f f f f f 0 q(f 0 ) for s A (f 0 ) Log q(f 0 ) for s logh/v (f 0 ) VALUTAZIONE EFFETTO DOPPIA RISONANZA Il progetto prevede la ristrutturazione di un fabbricato a tre piani adibiti ad uso commerciale. La frequenza di un edificio dipende dall altezza ossia dal numero dei piani e può essere calcolata approssimativamente secondo la formula:

23 Freq. edificio 10 Hz / n.piani La coincidenza di risonanza tra terreno e struttura può dar luogo a fenomeni di doppia risonanza sull edificio pericolosa in quanto provoca la massima amplificazione. Trattandosi di un edificio a tre piani la frequenza è pari a circa 3.3 Hz, dall indagine geofisica si osserva che a circa m di profondità dove la frequenza registrata è di circa 3 Hz non si osserva un cambio litologico, inoltre la frequenza caratteristica è di circa 4 Hz in corrispondenza di m di profondità, pertanto si tende ad escludere fenomeni di doppia risonanza sull edificio. PARAMETRI SISMICI Tipo di elaborazione: FONDAZIONI Sito in esame: C Latitudine: 44, Longitudine: 11, Classe d uso II: costruzioni con normale affollamento di persone, assenza di funzioni pubbliche e sociali importanti, industrie con attività non pericolose per l ambiente, ponti, strade e opere infrastrutturali non ricadenti in classe d uso III e IV, reti ferroviarie la cui interruzione non provochi situazioni di emergenza, dighe il cui collasso non provochi conseguenze rilevanti. Siti di riferimento: ID Latitudine Longitudine Distanza Sito , , ,8 Sito , , ,3 Sito , , ,0 Sito , , ,1 Categoria suolo: C Categoria topografica: T1 Vita nominale opera: 50 anni Coefficiente Cu: 1,0 Parametri sismici:

24 P VR % Tr (anni) ag (g) Fo (-) Tc* (s) Operatività SLO ,066 2,406 0,260 Danno SLD ,085 2,394 0,268 Salvaguardia vita SLV ,205 2,448 0,299 Prevenzione collasso SLC ,257 2, P VR = probabilità di superamento nel periodo di riferimento V R = 35 anni Tr = periodo di riferimento Fo = valore massimo del fattore di amplificazione dello spettro in accelerazione orr. Tc = periodo di inizio del tratto di velocità costante dello spettro di accelerazione orr. Coefficienti sismici: Ss (-) Cc (-) St (-) Kh (-) Kv (-) Amax (m/s 2 ) Beta (-) SLO 1,500 1,640 1,000 0,020 0,010 0,973 0,200 SLD 1,500 1,620 1,000 0,025 0,013 1,245 0,200 SLV 1,400 1,560 1,000 0,080 0,040 2,815 0,280 SLC 1,310 1,540 1,000 0,094 0,047 3,297 0,280 Ss = amplificazione stratigrafica Cc = coeff. funz. categoria St = amplificazione topografica Spettri di risposta

25 Zona 2 Tipo suolo ag S Tb (s) Tc (s) Td (s) piani T Sa Pianura 2 C ,3 0,78125 Dallo spettro di risposta normalizzato è possibile ottenere, moltiplicando i valori della tabella 1 per il valore di a refg di ogni comune,lo spettro di risposta a probabilità uniforme che descrive le caratteristiche del moto sismico atteso per ogni comune dell Emilia-Romagna. Figura - Spettro di risposta normalizzato (TR = 475 anni = 5% smorzamento) per l Emilia-Romagna T(s) 0, , , , , , , , ,00000 Sa/a ref 1, , , , , , , , ,23070 Tabella - Valori che definiscono lo spettro normalizzato per l Emilia-Romagna Valore di a refg per il comune di Imola = 0,205 dove a refg = accelerazione massima orizzontale di picco al suolo, cioè per T = 0, espressa in frazione dell accelerazione di gravità g (a refg ) Categorie topografiche del terreno T1 Superficie pianeggiante, pendii e rilievi isolate con inclinazione media i 15 St = 1 T2 Pendii con inclinazione media i 15 St =1.2 T3 Rilievi con larghezza in cresta minore che alla base e inclinazione media 15 i 30 St =1.2 T4 Rilievi con larghezza in cresta minore che alla base e inclinazione media i 30 St =1.4

26 Categorie suolo di fondazione C Descrizione del profilo stratigrafico V s30 (m/s) NSPT Cu (kpa) Depositi di sabbie o ghiaie mediamente addensate o argille di media consistenza con spessori variabili da diverse decine a centinaia di metri, caratterizzati da valori di V s30 compresi tra 180 e 360 m/s (15 < N SPT < 50, 70 < c u < 250 kpa) Parametri per il profilo stratigrafico S = 1,25, sabbie e ghiaie mediamente addensate, argille media consistenza, Tipo C; Tabella per il calcolo dei coefficienti di amplificazione sismica Pianura padana Pianura 2 sabbie prevalenti alternate a ghiaie substrato profondo 100 m Vs F.A. P.G.A F.A. I.S. 0.1s To 0.5s F.A. I.S. 0.5s To 1.0s

27 8 CONCLUSIONI Sulla base dei risultati ottenuti si può stabilire quanto segue: I terreni sono omogenei nell area infatti, nella zona indagata è presente terreno di riporto per circa 3 m cui sottostanno limi sabbiosi fino alla profondità di circa 8 m; a questa profondità si incontrano sabbie ghiaiose fino alla profondità di 22 m; Sulla base delle prove effettuate, dei calcoli effettuati per le verifiche di sicurezza relative agli stati limite ultimi (SLU) e della natura dei terreni, il terreno ha la seguente Tensione di progetto: Approccio 2 (A1+M1+R3 ) = 157,77 kn./m 2 Pur avendo calcolato una resistenza di progetto che nell approccio 2 è di 205,78 kn/m 2 per calcolare i cedimenti e mantenerli all interno di un range compatibile con gli interventi in progetto di un si è utilizzata la tensione normale di progetto pari a 70,0 kn/m² ottenendo un cedimento massimo di 1,55 cm. Secondo la classificazione del suolo, sulla base della nuova normativa sismica per gli edifici (D.M. 14/01/2008 recante "Norme tecniche per le costruzioni") in base ai dati ottenuti dalle indagini geognostiche in sito si classifica il terreno di fondazione del fabbricato come appartenente alla categoria C - Depositi di terreni a grana grossa mediamente addensati o terreni a grana fina mediamente consistenti con spessori superiori a 30 m, caratterizzati da un graduale miglioramento delle proprietà meccaniche con la profondità e da valori di Vs,30 compresi tra 180 m/s e 360 m/s (ovvero 15 < NSPT,30 < 50 nei terreni a grana grossa e 70 < cu,30 < 250 kpa nei terreni a grana fina) Attualmente nello strato di terreno analizzato insiste una falda freatica alla profondità di 7,5 m dal paiano campagna; La composizione litologica unita al facile drenaggio delle acque attraverso lo strato ghiaioso sottostante, permette di escludere la liquefazione dei terreni medesimi in presenza di evento sismico.

28 Dal punto di vista sismico: - Il terreno indagato e classificabile come sito C; - La Vs30 stimata è pari a 239 m/s; - Il manufatto previsto è classificato come classe d uso II; - Il fabbricato non è a rischio risonanza; - L accelerazione di gravita del sito è ag = 0,205 (SLV); - L accelerazione massima è Amax = 2,815 (SLV); - L accelerazione massima orizzontale di picco al suolo, cioè per T = 0, espressa in frazione dell accelerazione di gravità g (arefg) per il comune di Imola è 0,205; - La categoria topografica è T1; - L area è classificabile come pianura 2 con substrato oltre 100 m di profondità; - Si assumono come coefficienti di amplificazione sismica quelli relativi alla fascia di velocità pari a 250 m/s; - Il coefficiente di amplificazione sismica F.A. P.G.A è 1.5, F.A: I.S. per l intervallo 0.1s To 0.5s è 1,8, F.A. I.S. per l intervallo 0.5s To 1.0s è 2,3 Imola 13 dicembre 15 Il geologo Dott. Maurizio Castellari

29 Allegato 1 Ubicazione intervento Aree intervento

30 Allegato 2 Ubicazione prove

31 CPT 2 CPT 1

32 Allegato 3 Grafici prove penetrometriche

33 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 1 LETTURE DI CAMPAGNA / VALORI DI RESISTENZA committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -6,50m - pagina : 1 prf LP LL Rp RL Rp/Rl m Kg/cm² Kg/cm² Kg/cm² Kg/cm² - prf LP LL Rp RL Rp/Rl m Kg/cm² Kg/cm² Kg/cm² Kg/cm² - 0, , ,20 13,0 23,0 13,0 0,60 22,0 0,40 24,0 55,0 24,0 1,73 14,0 6,40 19,0 28,0 19,0 0,53 36,0 0,60 17,0 43,0 17,0 0,87 20,0 6,60 12,0 20,0 12,0 0,60 20,0 0,80 10,0 23,0 10,0 4,73 2,0 6,80 13,0 22,0 13,0 0,60 22,0 1,00 73,0 144,0 73,0 3,53 21,0 7,00 12,0 21,0 12,0 0,67 18,0 1,20 65,0 118,0 65,0 2,47 26,0 7,20 14,0 24,0 14,0 2,80 5,0 1,40 41,0 78,0 41,0 1,20 34,0 7,40 36,0 78,0 36,0 1,20 30,0 1,60 31,0 49,0 31,0 2,13 15,0 7,60 16,0 34,0 16,0 4,87 3,0 1,80 19,0 51,0 19,0 6,00 3,0 7,80 71,0 144,0 71,0 4,00 18,0 2,00 121,0 211,0 121,0 4,53 27,0 8,00 111,0 171,0 111,0 3,93 28,0 2,20 119,0 187,0 119,0 4,93 24,0 8,20 74,0 133,0 74,0 1,73 43,0 2,40 95,0 169,0 95,0 3,00 32,0 8,40 44,0 70,0 44,0 1,73 25,0 2,60 52,0 97,0 52,0 1,40 37,0 8,60 41,0 67,0 41,0 1,67 25,0 2,80 21,0 42,0 21,0 1,20 17,0 8,80 39,0 64,0 39,0 2,60 15,0 3,00 22,0 40,0 22,0 1,60 14,0 9,00 42,0 81,0 42,0 2,40 17,0 3,20 23,0 47,0 23,0 1,87 12,0 9,20 37,0 73,0 37,0 2,40 15,0 3,40 21,0 49,0 21,0 1,00 21,0 9,40 35,0 71,0 35,0 2,00 18,0 3,60 24,0 39,0 24,0 1,27 19,0 9,60 30,0 60,0 30,0 1,27 24,0 3,80 21,0 40,0 21,0 1,40 15,0 9,80 32,0 51,0 32,0 1,67 19,0 4,00 17,0 38,0 17,0 1,47 12,0 10,00 36,0 61,0 36,0 2,07 17,0 4,20 22,0 44,0 22,0 1,40 16,0 10,20 27,0 58,0 27,0 1,40 19,0 4,40 18,0 39,0 18,0 1,53 12,0 10,40 31,0 52,0 31,0 1,13 27,0 4,60 17,0 40,0 17,0 1,27 13,0 10,60 32,0 49,0 32,0 1,60 20,0 4,80 19,0 38,0 19,0 0,60 32,0 10,80 33,0 57,0 33,0 1,80 18,0 5,00 15,0 24,0 15,0 0,67 22,0 11,00 28,0 55,0 28,0 1,60 17,0 5,20 17,0 27,0 17,0 0,80 21,0 11,20 27,0 51,0 27,0 1,27 21,0 5,40 21,0 33,0 21,0 1,00 21,0 11,40 29,0 48,0 29,0 1,40 21,0 5,60 19,0 34,0 19,0 0,87 22,0 11,60 32,0 53,0 32,0 1,07 30,0 5,80 14,0 27,0 14,0 0,60 23,0 11,80 28,0 44,0 28,0 1,27 22,0 6,00 11,0 20,0 11,0 0,67 16,0 12,00 30,0 49,0 30, PENETROMETRO STATICO tipo GOUDA da 20 t - (con anello allargatore) - - COSTANTE DI TRASFORMAZIONE Ct = 10 - Velocità Avanzamento punta 2 cm/s - punta meccanica tipo Begemann ø = 35.7 mm (area punta 10 cm² - apertura 60 ) - manicotto laterale (superficie 150 cm²) Software by: Dr.D.Merlin /840820

34 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 2 LETTURE DI CAMPAGNA / VALORI DI RESISTENZA committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -5,50m - pagina : 1 prf LP LL Rp RL Rp/Rl m Kg/cm² Kg/cm² Kg/cm² Kg/cm² - prf LP LL Rp RL Rp/Rl m Kg/cm² Kg/cm² Kg/cm² Kg/cm² - 0, ,20 20,0 28,0 20,0 0,73 27,0 0, , ,40 12,0 23,0 12,0 0,53 22,0 0,60 36,0 47,0 36,0 0,53 67,0 5,60 16,0 24,0 16,0 0,80 20,0 0,80 34,0 42,0 34,0 1,07 32,0 5,80 15,0 27,0 15,0 0,87 17,0 1,00 18,0 34,0 18,0 0,80 22,0 6,00 13,0 26,0 13,0 1,00 13,0 1,20 24,0 36,0 24,0 1,20 20,0 6,20 16,0 31,0 16,0 0,47 34,0 1,40 26,0 44,0 26,0 1,40 19,0 6,40 12,0 19,0 12,0 0,60 20,0 1,60 38,0 59,0 38,0 2,33 16,0 6,60 14,0 23,0 14,0 0,80 17,0 1,80 31,0 66,0 31,0 1,87 17,0 6,80 17,0 29,0 17,0 1,07 16,0 2,00 28,0 56,0 28,0 1,60 17,0 7,00 31,0 47,0 31,0 1,20 26,0 2,20 24,0 48,0 24,0 1,27 19,0 7,20 35,0 53,0 35,0 0,87 40,0 2,40 31,0 50,0 31,0 2,87 11,0 7,40 21,0 34,0 21,0 0,80 26,0 2,60 51,0 94,0 51,0 1,87 27,0 7,60 17,0 29,0 17,0 0,40 42,0 2,80 26,0 54,0 26,0 1,47 18,0 7,80 11,0 17,0 11,0 0,53 21,0 3,00 19,0 41,0 19,0 1,47 13,0 8,00 10,0 18,0 10,0 1,33 7,0 3,20 21,0 43,0 21,0 1,53 14,0 8,20 23,0 43,0 23,0 6,27 4,0 3,40 23,0 46,0 23,0 1,60 14,0 8,40 108,0 202,0 108,0 6,20 17,0 3,60 24,0 48,0 24,0 1,53 16,0 8,60 183,0 276,0 183,0 6,00 30,0 3,80 26,0 49,0 26,0 1,07 24,0 8,80 231,0 321,0 231,0 0,80 289,0 4,00 18,0 34,0 18,0 1,00 18,0 9,00 40,0 52,0 40,0 0,93 43,0 4,20 23,0 38,0 23,0 0,60 38,0 9,20 50,0 64,0 50,0 1,53 33,0 4,40 13,0 22,0 13,0 0,60 22,0 9,40 36,0 59,0 36,0 1,53 23,0 4,60 29,0 38,0 29,0 1,53 19,0 9,60 38,0 61,0 38,0 1,47 26,0 4,80 26,0 49,0 26,0 1,27 21,0 9,80 35,0 57,0 35,0 1,60 22,0 5,00 14,0 33,0 14,0 0,53 26,0 10,00 39,0 63,0 39, PENETROMETRO STATICO tipo GOUDA da 20 t - (con anello allargatore) - - COSTANTE DI TRASFORMAZIONE Ct = 10 - Velocità Avanzamento punta 2 cm/s - punta meccanica tipo Begemann ø = 35.7 mm (area punta 10 cm² - apertura 60 ) - manicotto laterale (superficie 150 cm²) Software by: Dr.D.Merlin /840820

35 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 1 DIAGRAMMA DI RESISTENZA committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -6,50m - scala vert.: 1 : 100 Rp (kg/cm²) RL (kg/cm²) ,0 1,0 2,0 3,0 0,0 0,0 m. m. 1,0 1,0 2,0 2,0 3,0 3,0 4,0 4,0 5,0 5,0 6,0 6,0 7,0 7,0 8,0 8,0 9,0 9,0 10,0 10,0 11,0 11,0 12,0 12,0 13,0 13,0 14,0 14,0 15,0 15,0 16,0 16,0 17,0 17,0 18,0 18,0 Torbe e Argille Org 19,0 Argille e Limi Limi S. Sabbie Lim 19,0 Sabbie e Ghiaie 20,0 20, ,0 1,0 2,0 3,0 Software by: Dr.D.Merlin /840820

36 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 2 DIAGRAMMA DI RESISTENZA committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -5,50m - scala vert.: 1 : 100 Rp (kg/cm²) RL (kg/cm²) ,0 1,0 2,0 3,0 0,0 0,0 m. m. 1,0 1,0 2,0 2,0 3,0 3,0 4,0 4,0 5,0 5,0 6,0 6,0 7,0 7,0 8,0 8,0 9,0 9,0 10,0 10,0 11,0 11,0 12,0 12,0 13,0 13,0 14,0 14,0 15,0 15,0 16,0 16,0 17,0 17,0 18,0 18,0 Torbe e Argille Org 19,0 Argille e Limi Limi S. Sabbie Lim 19,0 Sabbie e Ghiaie 20,0 20, ,0 1,0 2,0 3,0 Software by: Dr.D.Merlin /840820

37 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 1 VALUTAZIONI LITOLOGICHE committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -6,50m - scala vert.: 1 : 100 m Rp/RL (Litologia Begemann 1965 A.G.I. 1977) Rp - RL/Rp (Litologia Schmertmann 1978) Torbe ed Limi ed Limi sabb. Sabbie e A Argille organiche Argille Sabbie lim. Sabbie e Ghiaie O A A A A A A S S S S S t t m c cc SL AL s m d C 0, ,0 0,0 1,0 1,0 1,0 2,0 2,0 2,0 3,0 3,0 3,0 4,0 4,0 4,0 5,0 5,0 5,0 6,0 6,0 6,0 7,0 7,0 7,0 8,0 8,0 8,0 9,0 9,0 9,0 10,0 10,0 10,0 11,0 11,0 11,0 12,0 12,0 12,0 13,0 13,0 13,0 14,0 14,0 14,0 15,0 15,0 15,0 16,0 16,0 16,0 17,0 17,0 17,0 18,0 18,0 18,0 19,0 19,0 19,0 20,0 20,0 20,0 Software by: Dr.D.Merlin /840820

38 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 2 VALUTAZIONI LITOLOGICHE committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -5,50m - scala vert.: 1 : 100 m Rp/RL (Litologia Begemann 1965 A.G.I. 1977) Rp - RL/Rp (Litologia Schmertmann 1978) Torbe ed Limi ed Limi sabb. Sabbie e A Argille organiche Argille Sabbie lim. Sabbie e Ghiaie O A A A A A A S S S S S t t m c cc SL AL s m d C 0, ,0 0,0 1,0 1,0 1,0 2,0 2,0 2,0 3,0 3,0 3,0 4,0 4,0 4,0 5,0 5,0 5,0 6,0 6,0 6,0 7,0 7,0 7,0 8,0 8,0 8,0 9,0 9,0 9,0 10,0 10,0 10,0 11,0 11,0 11,0 12,0 12,0 12,0 13,0 13,0 13,0 14,0 14,0 14,0 15,0 15,0 15,0 16,0 16,0 16,0 17,0 17,0 17,0 18,0 18,0 18,0 19,0 19,0 19,0 20,0 20,0 20,0 Software by: Dr.D.Merlin /840820

39 Dott. Saverio Tabanelli Via S. Lucia n Faenza (RA) Rifer PROVA PENETROMETRICA STATICA CPT 1 TABELLA PARAMETRI GEOTECNICI committente : Dott. Geol. Maurizio Castellari - data : 10/12/ lavoro : ristrutturazione - quota inizio : Piano Campagna - località : Imola, via Zappi - prof. falda : Falda non rilevata - note : Foro Chiuso a -6,50m - pagina : 1 NATURA COESIVA NATURA GRANULARE Prof. Rp Rp/Rl Natura Y' p'vo Cu OCR Eu50 Eu25 Mo Dr ø1s ø2s ø3s ø4s ødm ømy Amax/g E'50 E'25 Mo m kg/cm² (-) Litol. t/m³ kg/cm² kg/cm² (-) kg/cm² kg/cm² % ( ) ( ) ( ) ( ) ( ) ( ) (-) kg/cm² kg/cm² 0, ??? 1,85 0, , /:/: 1,85 0,07 0,89 99, , , //// 1,85 0,11 0,72 65, , //// 1,85 0,15 0,50 28, , /:/: 1,85 0,19 2,43 99, , , /:/: 1,85 0,22 2,17 99, , , :::: 1,85 0, , , /:/: 1,85 0,30 1,03 30, , , //// 1,85 0,33 0,78 18, , /:/: 1,85 0,37 4,03 99, , , /:/: 1,85 0,41 3,97 99, , , :::: 1,85 0, , , :::: 1,85 0, , , /:/: 1,85 0,52 0,82 11, , , /:/: 1,85 0,55 0,85 10, , , /:/: 1,85 0,59 0,87 10, , , /:/: 1,85 0,63 0,82 8, , , /:/: 1,85 0,67 0,89 9, , , /:/: 1,85 0,70 0,82 7, , , //// 1,85 0,74 0,72 6, , /:/: 1,85 0,78 0,85 7, , , //// 1,85 0,81 0,75 5, , //// 1,85 0,85 0,72 5, , /:/: 1,85 0,89 0,78 5, , , //// 1,85 0,93 0,67 4, , //// 1,85 0,96 0,72 4, , /:/: 1,85 1,00 0,82 4, , , //// 1,85 1,04 0,78 4, , //// 1,85 1,07 0,64 3, , //// 1,85 1,11 0,54 2, , //// 1,85 1,15 0,60 2, , /:/: 1,85 1,18 0,78 3, , , //// 1,85 1,22 0,57 2, , //// 1,85 1,26 0,60 2, , //// 1,85 1,30 0,57 2, , //// 1,85 1,33 0,64 2, , /:/: 1,85 1,37 1,20 5, , , //// 1,85 1,41 0,70 2, , /:/: 1,85 1,44 2,37 11, , , /:/: 1,85 1,48 3,70 19, , , :::: 1,85 1, , , /:/: 1,85 1,55 1,47 5, , , /:/: 1,85 1,59 1,37 5, , , /:/: 1,85 1,63 1,30 4, , , /:/: 1,85 1,66 1,40 5, , , /:/: 1,85 1,70 1,23 4, , , /:/: 1,85 1,74 1,17 3, , , /:/: 1,85 1,78 1,00 3, , , /:/: 1,85 1,81 1,07 3, , , /:/: 1,85 1,85 1,20 3, , , /:/: 1,85 1,89 0,95 2, , , /:/: 1,85 1,92 1,03 2, , , /:/: 1,85 1,96 1,07 2, , , /:/: 1,85 2,00 1,10 3, , , /:/: 1,85 2,03 0,97 2, , , /:/: 1,85 2,07 0,95 2, , , /:/: 1,85 2,11 0,98 2, , , /:/: 1,85 2,15 1,07 2, , , /:/: 1,85 2,18 0,97 2, , , :::: 1,85 2, , Software by: Dr.D.Merlin /840820

PERICOLOSITA SISMICA 2 VITA NOMINALE E CLASSE D USO 4 AZIONE SISMICA 5 CATEGORIA DEL SOTTOSUOLO E CONDIZIONI TOPOGRAFICHE 6

PERICOLOSITA SISMICA 2 VITA NOMINALE E CLASSE D USO 4 AZIONE SISMICA 5 CATEGORIA DEL SOTTOSUOLO E CONDIZIONI TOPOGRAFICHE 6 INDICE PERICOLOSITA SISMICA 2 VITA NOMINALE E CLASSE D USO 4 AZIONE SISMICA 5 CATEGORIA DEL SOTTOSUOLO E CONDIZIONI TOPOGRAFICHE 6 SPETTRI E PARAMETRI DI STRUTTURA 7 1 PERICOLOSITA SISMICA L azione sismica

Dettagli

5. CALCOLO DELL AZIONE SISMICA DI PROGETTO (NORME TECNICHE PER LE COSTRUZIONI D.M. 14 GENNAIO 2008)

5. CALCOLO DELL AZIONE SISMICA DI PROGETTO (NORME TECNICHE PER LE COSTRUZIONI D.M. 14 GENNAIO 2008) 5. CALCOLO DELL AZIONE SISMICA DI PROGETTO (NORME TECNICHE PER LE COSTRUZIONI D.M. 14 GENNAIO 2008) L azione sismica di progetto si definisce a partire dalla pericolosità sismica di base del sito d interesse

Dettagli

ALLEGATO N.9 Portanza e cedimenti - valutazioni preliminari

ALLEGATO N.9 Portanza e cedimenti - valutazioni preliminari ALLEGATO N.9 Portanza e cedimenti - valutazioni preliminari DATI GENERALI Azione sismica NTC 2008 Lat./ Long. [WGS84] 43,618868/10,642293 Larghezza fondazione 1,2 m Lunghezza fondazione 10,0 m Profondità

Dettagli

FACOLTÀ DI ARCHITETTURA

FACOLTÀ DI ARCHITETTURA UNIVERSITÀ DEGLI STUDI DI CATANIA FACOLTÀ DI ARCHITETTURA Corso di Costruzioni in zona sismica A.A. 2007-2008 dott. ing. Marco Muratore Lezione 4: dall equazione del moto allo spettro di risposta elastico

Dettagli

Università IUAV di Venezia

Università IUAV di Venezia Università IUAV di Venezia corso : Fondazioni a.a. 2016-17 17 D.M.14.01.2008.14.01.2008 - cap. 6 Progettazione geotecnica 6.2.2 INDAGINI, CARATTERIZZAZIONE E MODELLAZIONE GEOTECNICA Le indagini geotecniche

Dettagli

Corso di Laurea in Scienze Geologiche Corso di Geologia Applicata. Domenico Calcaterra

Corso di Laurea in Scienze Geologiche Corso di Geologia Applicata. Domenico Calcaterra Corso di Laurea in Scienze Geologiche Corso di Geologia Applicata Il modello geologico e geotecnico del sottosuolo Domenico Calcaterra Dipartimento di Scienze della Terra, dell Ambiente e delle Risorse

Dettagli

NORMATIVE DI RIFERIMENTO...

NORMATIVE DI RIFERIMENTO... SOMMARIO 1. PREMESSA... 1 2. NORMATIVE DI RIFERIMENTO... 2 3. AZIONE SISMICA... 3 3.1. CATEGORIA DI SOTTOSUOLO E CONDIZIONI TOPOGRAFICHE... 3 3.2. SPETTRO DI RISPOSTA ELASTICO IN ACCELERAZIONE DELLE COMPONENTI

Dettagli

RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE

RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE Proprietà: Ubicazione: RONCONI & LIVERANI Srl Comune di Cotignola Via Madonna di Genova n 39/41 Prog. e DDL Strutturale: Progetto architettonico: Ing. Peroni

Dettagli

PORTO TURISTICO DI ROMA RELAZIONE GEOTECNICA E SISMICA

PORTO TURISTICO DI ROMA RELAZIONE GEOTECNICA E SISMICA PORTO TURISTICO DI ROMA PROGETTO DI AMPLIAMENTO PROGETTO DEFINITIVO RELAZIONE GEOTECNICA E SISMICA INDICE 1. GENERALITÀ... 2 2. NORMATIVE DI RIFERIMENTO... 2 3. CARATTERIZZAZIONE GEOTECNICA... 3 3.1 Caratteristiche

Dettagli

A2.1 - Tabelle per il calcolo dei coefficienti di amplificazione sismica (secondo livello di approfondimento)

A2.1 - Tabelle per il calcolo dei coefficienti di amplificazione sismica (secondo livello di approfondimento) ALLEGATO A2 TABELLE E FORMULE PER LA VALUTAZIONE DEI FATTORI DI AMPLIFICAZIONE SISMICA PER LE ANALISI DEL SECONDO LIVELLO DI APPROFONDIMENTO E PER LA VALUTAZIONE DEGLI EFFETTI TOPOGRAFICI. A2.1 - Tabelle

Dettagli

PROVA PENETROMETRICA STATICA CPT 1 LETTURE DI CAMPAGNA / VALORI DI RESISTENZA 3.010496-143

PROVA PENETROMETRICA STATICA CPT 1 LETTURE DI CAMPAGNA / VALORI DI RESISTENZA 3.010496-143 PROVA PENETROMETRICA STATICA CPT 1 LETTURE DI CAMPAGNA / VALORI DI RESISTENZA 3.010496-143 - resp. cantiere: prf LP LL Rp RL Rp/Rl - - Kg/c² Kg/c² - prf LP LL Rp RL Rp/Rl - - Kg/c² Kg/c² - 0,20 ---- ----

Dettagli

BASE SISMICA A RIFRAZIONE ST1P (TAV. 2)

BASE SISMICA A RIFRAZIONE ST1P (TAV. 2) BASE SISMICA A RIFRAZIONE ST1P (TAV. 2) 1. Il sismostrato-1 è caratterizzato da velocità delle onde P di comprese tra 480 m/sec e 540 m/sec; lo spessore di questo sismostrato è variabile: circa 1 m. (scoppio

Dettagli

Relazione sulla pericolosità sismica del sito

Relazione sulla pericolosità sismica del sito Relazione sulla pericolosità sismica di base del sito interessato dalle costruzioni PROGETTO PER L'ADEGUAMENTO SISMICO DELLA SCUOLA MATERNA "V.Foscolo" Relazione sulla pericolosità sismica del sito f l

Dettagli

PROVEPENETROMETRICHESTATICHEEDINAMICHESUPERPESANTI

PROVEPENETROMETRICHESTATICHEEDINAMICHESUPERPESANTI PROVEPENETROMETRICHESTATICHEEDINAMICHESUPERPESANTI Attestazione n. 1675-6/00 CERTIFICAZIONE ITALIANA DEI SISTEMI DI QUALITA AZIENDALI Cert. n. 9175.MAPP Indagine geognostica in localitä Pescia Variante

Dettagli

Regione. Regione Calabria. Comune Comune di Rogliano di (CS) ... PROGETTO ESECUTIVO IMPIANTO MINIEOLICO EX SCUOLA MATERNA "POVERELLA"

Regione. Regione Calabria. Comune Comune di Rogliano di (CS) ... PROGETTO ESECUTIVO IMPIANTO MINIEOLICO EX SCUOLA MATERNA POVERELLA POI Energie Rinnovabili e Risparmio Energetico LINEA DI ATTIVITÀ 1.3 INTERVENTI A SOSTEGNO DELLA PRODUZIONE DI ENERGIA DA FONTI RINNOVABILI NELL AMBITO DELL EFFICIENTAMENTO ENERGETICO DEGLI EDIFICI E UTENZE

Dettagli

INDICE. 2.1 Cenni teorici sul metodo di Nakamura Pag Modalità di acquisizione Pag Elaborazione dati Pag. 3

INDICE. 2.1 Cenni teorici sul metodo di Nakamura Pag Modalità di acquisizione Pag Elaborazione dati Pag. 3 INDICE 1. Introduzione Pag. 2 2. Registrazione Microtremori Pag. 2 2.1 Cenni teorici sul metodo di Nakamura Pag. 2 2.2 Modalità di acquisizione Pag. 3 2.3 Elaborazione dati Pag. 3 1 1. INTRODUZIONE Su

Dettagli

RELAZIONE GEOTECNICA E SULLE FONDAZIONI

RELAZIONE GEOTECNICA E SULLE FONDAZIONI RELAZIONE GEOTECNICA E SULLE FONDAZIONI 1 Indice 1. Caratterizzazione geotecnica dei terreni di fondazione...3 2. Criteri di scelta del tipo di fondazione...4 3. Caratterizzazione meccanica...4 4. Descrizione

Dettagli

Nuova zonazione sismica e procedure per la valutazione degli effetti sismici di sito nel territorio lombardo

Nuova zonazione sismica e procedure per la valutazione degli effetti sismici di sito nel territorio lombardo Nuova zonazione sismica e procedure per la valutazione degli effetti sismici di sito nel territorio lombardo F. Pergalani, M. Compagnoni, M.P. Boni Politecnico di Milano - Dipartimento di Ingegneria Strutturale,

Dettagli

RELAZIONE GEOLOGICA E MODELLO GEOLOGICO

RELAZIONE GEOLOGICA E MODELLO GEOLOGICO Dr. Paolo Giovagnoli Geologo Comuni di Cividale del Friuli e Buttrio Provincia di Udine RELAZIONE GEOLOGICA E MODELLO GEOLOGICO a supporto del progetto di collaborazione transfrontaliera per il miglioramento

Dettagli

INDICE 1. PREMESSA ASPETTI GEOLOGICI INQUADRAMENTO GEOMORFOLOGICO ED IDROLOGICO...4

INDICE 1. PREMESSA ASPETTI GEOLOGICI INQUADRAMENTO GEOMORFOLOGICO ED IDROLOGICO...4 PIANO DI LOTTIZZAZIONE "PL MICHIELI 1" - Z.T.O. C2.1 RELAZIONE GEOLOGICA E GEOTECNICA INDICE 1. PREMESSA...3 2. ASPETTI GEOLOGICI...3 3. INQUADRAMENTO GEOMORFOLOGICO ED IDROLOGICO...4 4. VALUTAZIONI LITOLOGICHE

Dettagli

L obiettivo è stato quello di verificare la relazione Rd > Ed, come indicato nelle NTC2008 al paragrafo 2.3.

L obiettivo è stato quello di verificare la relazione Rd > Ed, come indicato nelle NTC2008 al paragrafo 2.3. 1) PREMESSA La presente relazione viene redatta in supporto al progetto dell ampliamento della scuola secondaria di primo grado Istituto comprensivo Erasmo da Rotterdam sita in Via Giovanni XXIII, 8 a

Dettagli

Geo Probing - PROVE PENETROMETRICHE STATICHE - RAPPORTO ED ELABORAZIONE DEI VALORI MISURATI DOCUMENTAZIONE FOTOGRAFICA

Geo Probing - PROVE PENETROMETRICHE STATICHE - RAPPORTO ED ELABORAZIONE DEI VALORI MISURATI DOCUMENTAZIONE FOTOGRAFICA Geo Probing di Francesco Becattini Telefono cellulare: 347.6434222 Sede: Strada Perugia - Ponte Valleceppi, n 96 06135 Ponte Valleceppi (PG) Telefono e Fax: 075.5928321 e-mail: f.becattini@geoprobing.it

Dettagli

Università IUAV di Venezia corso : Fondamenti di Geotecnica a.a

Università IUAV di Venezia corso : Fondamenti di Geotecnica a.a Università IUAV di Venezia corso : Fondamenti di Geotecnica a.a. 2016-17 17 Progettazione GEOTECNICA Progetto e realizzazione: - delle opere di fondazione; - delle opere di sostegno; - delle opere in sotterraneo;

Dettagli

ALLEGATO C (Classi di Rischio Geologico e indagini di tipo geologico, geofisico e geotecnico minime da eseguire)

ALLEGATO C (Classi di Rischio Geologico e indagini di tipo geologico, geofisico e geotecnico minime da eseguire) ALLEGATO C (Classi di Geologico e indagini di tipo geologico, geofisico e geotecnico minime da eseguire) Il testo del presente allegato è stato redatto in collaborazione tra la Direzione Regionale Infrastrutture

Dettagli

SPETTRO DI RISPOSTA ELASTICO SPETTRO DI PROGETTO

SPETTRO DI RISPOSTA ELASTICO SPETTRO DI PROGETTO SPETTRO DI RISPOSTA ELASTICO SPETTRO DI PROGETTO 1 (Ridis. con modifiche da M. De Stefano, 2009) 2 3 Concetto di duttilità 4 5 6 7 E necessario avere i valori di q dallo strutturista ( ma anche qo). Per

Dettagli

PERIZIA GEOLOGICO - TECNICA

PERIZIA GEOLOGICO - TECNICA INDAGINI GEOGNOSTICHE E GEOLOGIA Sede legale: via Giovanni XXIII n. 58 * 44123 Ferrara * Tel./fax: 0532750877 Cell.: 3392256531 * E-mail: mastellarim@alice.it * P.IVA: 01561570381 PROVINCIA DI FERRARA

Dettagli

Si compone di sue sezioni distinte, rispettivamente identificate come: INQUADRAMENTO SISMICO CARATTERIZZAZIONE DEI MATERIALI DEL SUBSTRATO

Si compone di sue sezioni distinte, rispettivamente identificate come: INQUADRAMENTO SISMICO CARATTERIZZAZIONE DEI MATERIALI DEL SUBSTRATO 1.0 PREMESSA La presente relazione tecnica espone l inquadramento sismico del sito e la caratterizzazione geotecnica del substrato dell area in cui è prevista la realizzazione del Parcheggio A e del Parcheggio

Dettagli

PROGETTAZIONE PER AZIONI SISMICHE

PROGETTAZIONE PER AZIONI SISMICHE PROGETTAZIONE PER AZIONI SISMICHE 3.2 AZIONE SISMICA Le azioni sismiche di progetto si definiscono a partire dalla pericolosità sismica di base del sito di costruzione, che è descritta dalla probabilità

Dettagli

Geo Tecnologie s.r.l.

Geo Tecnologie s.r.l. INDICE 1. PREMESSA 2 2. DECRETO MINISTERIALE 14 GENNAIO 2008 7 2.1 Parametri sismici locali 9 1 1. PREMESSA L Appennino meridionale presenta una storia sismica tra le più severe dell Italia, sia in termini

Dettagli

Integrazione alla relazione geologica-geotecnica

Integrazione alla relazione geologica-geotecnica COMUNE DI NUMANA Provincia di Ancona REALIZZAZIONE NUOVO POLO SCOLASTICO MARCELLI IN VIA BOLOGNA COMMITTENTE: COMUNE DI NUMANA Integrazione alla relazione geologica-geotecnica dicem br e 20 16 1 COMUNE

Dettagli

REGIONE LIGURIA PROVINCIA DI SAVONA. COMUNE di BOISSANO

REGIONE LIGURIA PROVINCIA DI SAVONA. COMUNE di BOISSANO REGIONE LIGURIA PROVINCIA DI SAVONA COMUNE di BOISSANO VARIANTE AL PIANO URBANISTICO COMUNALE, PER OPERE DI DEMOLIZIONE CON TRASFERIMENTO DELLA VOLUMETRIA AD ALTRO LOTTO E INCREMENTO DI VOLUME PER LA REALIZZAZIONE

Dettagli

PROGETTO DI UN NUOVO ALLEVAMENTO DI GALLINE OVAIOLE PERIZIA GEOLOGICA E GEOTECNICA 1/21/2015

PROGETTO DI UN NUOVO ALLEVAMENTO DI GALLINE OVAIOLE PERIZIA GEOLOGICA E GEOTECNICA 1/21/2015 PROVINCIA DI VENEZIA COMUNE DI SAN STINO DI LIVENZA 1/21/2015 PROGETTO DI UN NUOVO ALLEVAMENTO DI GALLINE OVAIOLE ELAB. 05 PERIZIA GEOLOGICA E GEOTECNICA Proponente : C.P.T. Farm Società Agricola S.r.l.

Dettagli

REGIONE VENETO ULSS n. 18 ROVIGO

REGIONE VENETO ULSS n. 18 ROVIGO REGIONE VENETO ULSS n. 18 ROVIGO Viale Tre Martiri, 89 45100 R O V I G O A47 - PROGETTO PRELIMINARE RELAZIONE DI INQUADRAMENTO GEOTECNICO 1.0 PREMESSE Il progetto prevede la costruzione di un nuovo corpo

Dettagli

Relazione Geotecnica e sulle Fondazioni

Relazione Geotecnica e sulle Fondazioni Relazione Geotecnica e sulle Fondazioni 1. Premessa In Italia la progettazione geotecnica è regolata dal N.T.C. 2008 ed è redatta ai sensi del p.to 6.2.2. La presente Relazione è relativa all Analisi sulle

Dettagli

Allegato 1: Verifica sismica di 2 livello Allegato 2: Prove penetrometriche dinamiche

Allegato 1: Verifica sismica di 2 livello Allegato 2: Prove penetrometriche dinamiche STUDIO GEOPLAN Via C. Rota, 39 Monza Tel. 039/832781 INDICE 1 Premessa... 1 2 Ubicazione dell area... 1 3 Inquadramento geologico... 1 4 Condizioni idrogeologiche... 2 4.1 P... 2 5 Fattibilità geologica...

Dettagli

Valutazione del rischio strutturale degli ambienti di lavoro

Valutazione del rischio strutturale degli ambienti di lavoro Valutazione del rischio strutturale degli ambienti di lavoro Vulnerabilità sismica delle strutture: il caso di un capannone tipo in area industriale Dott. Ing. Giuseppe Buda www.budaingegneria.jimdo.com

Dettagli

INDICE. 1. PREMESSA p INDAGINE GEOSISMICA PERICOLOSITÀ SISMICA DI BASE CONCLUSIONI..12 TAVOLE FIGURE

INDICE. 1. PREMESSA p INDAGINE GEOSISMICA PERICOLOSITÀ SISMICA DI BASE CONCLUSIONI..12 TAVOLE FIGURE Dott. ssa Geol. Maddalena A. Corvasce Studio: Via M. Sante, 44 Barletta. Partita I.V.A. 05288440729 Cell. 320 0698790, Email: maddi.corvasce@libero.it Progetto per la realizzazione di 1160 nicchie funerarie

Dettagli

ALLEGATO A Misure di microtremore sismico mediante tecnica HVSR a stazione singola (Micromed TROMINO)

ALLEGATO A Misure di microtremore sismico mediante tecnica HVSR a stazione singola (Micromed TROMINO) dr. geol. Michela PECCHIO via Crocefisso, 37F 24123 Bergamo (BG) Dott. Geol. Gianluigi Nozza ALLEGATO A Misure di microtremore sismico mediante tecnica HVSR a stazione singola (Micromed TROMINO) ELENCO

Dettagli

PROVINCIA AUTONOMA DI TRENTO PERICOLOSITA SISMICA DEL TERRITORIO PROVINCIALE E CALCOLO DELL AZIONE SISMICA LOCALE

PROVINCIA AUTONOMA DI TRENTO PERICOLOSITA SISMICA DEL TERRITORIO PROVINCIALE E CALCOLO DELL AZIONE SISMICA LOCALE PROVINCIA AUTONOMA DI TRENTO SERVIZIO GEOLOGICO PERICOLOSITA SISMICA DEL TERRITORIO PROVINCIALE E CALCOLO DELL AZIONE SISMICA LOCALE dott. Andrea Franceschini Calcolo della pericolosità sismica: cosa occorre

Dettagli

R.02C - Relazione geologica - geotecnica

R.02C - Relazione geologica - geotecnica Via XXV Aprile, 18 - Rovato COMUNE DI FLERO PROVINCIA DI BRESCIA AMPLIAMENTO IMPIANTO DI DEPURAZIONE DELLE ACQUE REFLUE DEL COMUNE DI FLERO PROGETTO DEFINITIVO R.02C - Relazione geologica - geotecnica

Dettagli

COMUNE DI PONTE DELL'OLIO Provincia di Piacenza

COMUNE DI PONTE DELL'OLIO Provincia di Piacenza COMUNE DI PONTE DELL'OLIO Provincia di Piacenza COMUNE DI PONTE DELL'OLIO PIANO COMUNALE DI PROTEZIONE CIVILE RISCHIO SISMICO 1^ Edizione - Marzo 2012: Dott. Geol. Paolo Mancioppi Studio Geologico 2^ Edizione

Dettagli

Corsi di Geotecnica A ed Elementi di Geotecnica

Corsi di Geotecnica A ed Elementi di Geotecnica Università degli Studi di Trento Facoltà di Ingegneria Corsi di Laurea in Ingegneria per l Ambiente ed il Territorio (triennale) Ingegneria del Controllo Ambientale Corsi di Geotecnica A ed Elementi di

Dettagli

COSTRUZIONI CASSARA DI CASSARA GEOM. ANTONINO C.SO TORINO, 55 VIGEVANO RELAZIONE GEOLOGICA DI FATTIBILITA

COSTRUZIONI CASSARA DI CASSARA GEOM. ANTONINO C.SO TORINO, 55 VIGEVANO RELAZIONE GEOLOGICA DI FATTIBILITA COMUNE DI VIGEVANO Provincia di Pavia COMMITTENTE COSTRUZIONI CASSARA DI CASSARA GEOM. ANTONINO C.SO TORINO, 55 VIGEVANO PROGETTO PL VIA VALLETTA FOGLIANO RELAZIONE GEOLOGICA DI FATTIBILITA Dott.Geol.

Dettagli

COMUNE DI FIRENZE PROGETTO DI UNA PLATEA DI FONDAZIONE

COMUNE DI FIRENZE PROGETTO DI UNA PLATEA DI FONDAZIONE COMUNE DI FIRENZE PROGETTO DI UNA PLATEA DI FONDAZIONE A3 - RELAZIONE TECNICA GENERALE A4 - Relazione sui materiali A8 Relazione di calcolo Progettista: Ing. Marco Gori Ordine Ingegneri di Firenze n 3546

Dettagli

NORME TECNICHE DELLE COSTRUZIONI 2008

NORME TECNICHE DELLE COSTRUZIONI 2008 NORME TECNICHE DELLE COSTRUZIONI 2008 Dal 1/07/09 la ricostruzione del modello geotecnico e geologico nonché la progettazione e conseguentemente le indagini geotecniche devono essere realizzate in accordo

Dettagli

COMUNE DI ALGHERO PROVINCIA DI SASSARI PROGETTO ADEGUAMENTO INFRASTRUTTURE VOLO ICAO MIGLIORAMENTO ACCESSIBILITA AEROPORTO

COMUNE DI ALGHERO PROVINCIA DI SASSARI PROGETTO ADEGUAMENTO INFRASTRUTTURE VOLO ICAO MIGLIORAMENTO ACCESSIBILITA AEROPORTO COMUNE DI ALGHERO PROVINCIA DI SASSARI PROGETTO ADEGUAMENTO INFRASTRUTTURE VOLO ICAO MIGLIORAMENTO ACCESSIBILITA AEROPORTO Committente : SO.GE.A.AL. Società di gestione Aeroporto di Alghero - Fertilia

Dettagli

VALUTAZIONE DELL'AZIONE SISMICA

VALUTAZIONE DELL'AZIONE SISMICA C.T.E. COLLEGIO DEI TECNICI DELLA INDUSTRIALIZZAZIONE EDILIZIA ORDINE DEGLI INGEGNERI DELLA PROVINCIA DI NUORO CORSO DI AGGIORNAMENTO PROGETTAZIONE DELLE STRUTTURE DI CALCESTRUZZO CON GLI EUROCODICI alla

Dettagli

AUTOSTRADA AT CN S.p.A. Loc. svincolo Alba Ovest DISCARICA PER RIFIUTI NON PERICOLOSI INDICE

AUTOSTRADA AT CN S.p.A. Loc. svincolo Alba Ovest DISCARICA PER RIFIUTI NON PERICOLOSI INDICE INDICE 1. PREMESSA... 1 2. NORMATIVE DI RIFERIMENTO... 1 3. SISMICITA... 2 3.1 CARATTERIZZAZIONE DELLA PERICOLOSITÀ SISMICA... 3 3.2 CALCOLO DELL AZIONE SISMICA DI PROGETTO... 7 3.2.1 Individuazione della

Dettagli

Progetto definitivo RD.3.4 RELAZIONE GEOTECNICA PALAZZINA UFFICI VERIFICA PORTANZA TERRENO. BRUNDISIUM S.p.A..

Progetto definitivo RD.3.4 RELAZIONE GEOTECNICA PALAZZINA UFFICI VERIFICA PORTANZA TERRENO. BRUNDISIUM S.p.A.. COMUNE DI BRINDISI (BR) PROGETTO PER LA REALIZZAZIONE DI UN DEPOSITO COSTIERO DI IDROCARBURI - GASOLIO E BENZINA CON ANNESSO TERMINALE DI CARICO SITO NELL AREA PROSPICIENTE LA BANCHINA COSTA MORENA RIVA

Dettagli

Progettista: Committente :

Progettista: Committente : Progettista: Committente : Dott. Ing. Salano Claudio ASL 4 Via E. Toti 18/A Azienda Sanitaria Chiavarese 16033 Lavagna GE Tel. 0185 310260 OGGETTO : Realizzazione di volume tecnico Via G.B. Ghio n 9-16043

Dettagli

Img. 1.1 Tracciato previsto dal PRG pre vigente del Comune di Bologna

Img. 1.1 Tracciato previsto dal PRG pre vigente del Comune di Bologna PROVINCIA DI BOLOGNA Settore Pianificazione Territoriale e Trasporti Documento: Relazione Geotecnica Studio di fattibilità del III lotto della strada Lungosavena a Bologna Cod.: S10011-SF-GE02-0 Data:

Dettagli

1 PREMESSA 1.1 Lavoro eseguito

1 PREMESSA 1.1 Lavoro eseguito 1 PREMESSA Il Committente Consorzio di Bonifica dell Ufita intende effettuare i lavori di costruzione di una vasca di accumulo e stazione di sollevamento nell ambito del progetto di adeguamento del comprensorio

Dettagli

(Integrazione) Fano, 05 Febbraio 2010 O G G E T T O. ASCLEPIO s.r.l. Associazione Cante di Montevecchio Onlus

(Integrazione) Fano, 05 Febbraio 2010 O G G E T T O. ASCLEPIO s.r.l. Associazione Cante di Montevecchio Onlus R E G I O N E M A R C H E P R O V I N C I A D I P E S A R O E U R B I N O COMUNE DI FANO O G G E T T O INTEGRAZIONE DELLA RELAZIONE GEOLOGICA, IN ADEGUAMENTO ALLE N.T.C., PER IL PROGETTO DI RISTRUTTURAZIONE

Dettagli

Dr. Fabrizio VIGNA - GEOLOGO SOMMARIO

Dr. Fabrizio VIGNA - GEOLOGO SOMMARIO SOMMARIO 1 INTRODUZIONE...2 1.1 NORMATIVA DI RIFERIMENTO... 4 2 INQUADRAMENTO GEOLOGICO - GEOMORFOLOGICO...5 3 INQUADRAMENTO IDROGEOLOGICO...7 4.1 UBICAZIONE POZZETTI GEOGNOSTICI... 10 4.2 STRATIGRAFIA

Dettagli

E 03 COMUNE DI LOANO OGGETTO: RELAZIONE SULLA PERICOLOSITA' SISMICA ELABORATO SOGGETTI ATTUATORI SOC. MATRIX SRL.

E 03 COMUNE DI LOANO OGGETTO: RELAZIONE SULLA PERICOLOSITA' SISMICA ELABORATO SOGGETTI ATTUATORI SOC. MATRIX SRL. COMUNE DI LOANO PIANO PARTICOLAREGGIATO DI INIZIATIVA PRIVATA IN VARIANTE CONTESTUALE AL VIGENTE P.R.G. PER LA RIQUALIFICAZIONE URBANISTICA DEI COMPARTI MAZZOCCHI E TREXENDE SOGGETTI ATTUATORI SOC. MATRIX

Dettagli

Giornata di studio. Approfondimenti sul paragrafo 4 dello Standard Minimo Modellazione sismica

Giornata di studio. Approfondimenti sul paragrafo 4 dello Standard Minimo Modellazione sismica ORDINE DEI GEOLOGI DELLA REGIONE UMBRIA Aggiornamento Professionale Continuativo Giornata di studio Metodo d'approccio e stato di applicazione dello Standard minimo per la redazione della Relazione Geologica

Dettagli

GeoLOG SUBSOIL EXPLORATION

GeoLOG SUBSOIL EXPLORATION RAPPORTO GEOLOGICO MODELLAZIONE SOTTOSUOLO SISMICA (D.M. 14.01.2008) PROGETTO: PIANO ATTUATIVO IN VARIANTE AL PRG COMPARTO f ISTITUTO CANOSSIANE Loc.tà: Istituto Suore Canossiane Comune di PORTO SAN GIORGIO

Dettagli

Esame di Stato per Geologo. Sede Urbino 2 sessione Prima prova scritta. risanamento che possono riguardare la professione del geologo.

Esame di Stato per Geologo. Sede Urbino 2 sessione Prima prova scritta. risanamento che possono riguardare la professione del geologo. Esame di Stato per Geologo Sede Urbino 2 sessione 2013 Prima prova scritta 1) La Geologia e l'inquinamento ambientale: vari tipi di inquinamento, tecniche di indagine e di risanamento che possono riguardare

Dettagli

COMUNE DI FALERNA PROV. CATANZARO

COMUNE DI FALERNA PROV. CATANZARO COMUNE DI FALERNA PROV. CATANZARO Progetti Integrati di Sviluppo Locale del POR Calabria FERS 2007-2013 Provincia di Catanzaro-PISL "Pisl Costa degli Ulivi. Tipologia : Sistemi Turistici. Riqualificazione

Dettagli

Comune di Paesana (CN) Febbraio 2015

Comune di Paesana (CN) Febbraio 2015 Comune di Paesana (CN) - 1 - Febbraio 2015 1. Comune di Paesana (CN) - 2 - Febbraio 2015 INTRODUZIONE Il sottoscritto Ing. Franco Picotto, su incarico del Comune di Paesana ha redatto il presente documento

Dettagli

RELAZIONE GEOTECNICA SULLE FONDAZIONI

RELAZIONE GEOTECNICA SULLE FONDAZIONI RELAZIONE GEOTECNICA SULLE FONDAZIONI Dati generali Oggetto : Realizzazione di n. 3 blocchi loculari uguali da 240 posti ciascuno Comune : Anzio (RM) Località : Cimitero. Zona sismica : 3 sottozona A Altitudine

Dettagli

COMUNE DI RICCIONE (PROVINCIA DI RIMINI)

COMUNE DI RICCIONE (PROVINCIA DI RIMINI) COMUNE DI RICCIONE (PROVINCIA DI RIMINI) INDAGINI GEOLOGICHE GEOGNOSTICHE E SISMICHE CONNESSE ALLA IV VARIANTE DEL PIANO DELL ARENILE. COMMITTENTE: COMUNE DI RICCIONE Dott. Geol. Giancarlo Faina Montefiore

Dettagli

Relazione geologica. Premessa

Relazione geologica. Premessa Relazione geologica Oggetto: studio geologico sull area sita in via F. Saporito, nel Comune di Aversa (Ce), di proprietà Comunale, destinata all intervento di completamento, manutenzione straordinaria

Dettagli

RELAZIONE DI CALCOLO PRELIMINARE INDICE

RELAZIONE DI CALCOLO PRELIMINARE INDICE RELAZIONE DI CALCOLO PRELIMINARE INDICE Descrizione intervento... 1 Normativa di riferimento... 2 Modello geotecnico... 3 Parametri e metodologia di calcolo... 4 Criteri di verifica della paratia... 4

Dettagli

DOTT. GIANLUCA CANTARELLI GEOLOGO

DOTT. GIANLUCA CANTARELLI GEOLOGO DOTT. GIANLUCA CANTARELLI GEOLOGO PROVINCIA DI PARMA COMUNE DI SALSOMAGGIORE TERME INDAGINI GEOGNOSTICHE INERENTI IL MOVIMENTO FRANOSO INTERESSANTE LA STRADA COMUNALE DI MONTAURO IN COMUNE DI SALSOMAGGIORE

Dettagli

Via Pinarella. Relazione geotecnica e sulle fondazioni Edificio Sud. Comune di Cervia (Ra)

Via Pinarella. Relazione geotecnica e sulle fondazioni Edificio Sud. Comune di Cervia (Ra) Via Pinarella Relazione geotecnica e sulle fondazioni Relazione geotecnica e sulle fondazioni Edificio Sud Via Pinarella Comune di Cervia (Ra) INDICE INDICE... 1 1 Descrizione della struttura di fondazione...

Dettagli

REGOLAMENTO URBANISTICO PROSPEZIONI SISMICHE A RIFRAZIONE CON ONDE P E SH

REGOLAMENTO URBANISTICO PROSPEZIONI SISMICHE A RIFRAZIONE CON ONDE P E SH COMUNE DI COREGLIA ANTELMINELLI Provincia di Lucca REGOLAMENTO URBANISTICO PROSPEZIONI SISMICHE A RIFRAZIONE CON ONDE P E SH CATEGORIE DEI SUOLI DI FONDAZIONE AI SENSI DEL D.M. 14/09/05 NEL CAPOLUOGO E

Dettagli

ALLEGATO 2 SCHEDE REGIONALI PER LA VALUTAZIONE DEL FATTORE DI AMPLIFICAZIONE

ALLEGATO 2 SCHEDE REGIONALI PER LA VALUTAZIONE DEL FATTORE DI AMPLIFICAZIONE ALLEGATO SCHEDE REGIONALI PER LA VALUTAZIONE DEL FATTORE DI AMPLIFICAZIONE ALLEGATO EFFETTI MORFOLOGICI SCARPATA - SCENARIO Za CRITERI DI RICONOSCIMENTO h β H m α L α H L H oppure L > - m SCARPATA IN CONTROPENDENZA

Dettagli

INDICE 1. PREMESSE... 3 2. INQUADRAMENTO GEOLOGICO E GEOMORFOLOGICO... 4 3.CARATTERIZZAZIONE SISMICA DEL SITO... 12

INDICE 1. PREMESSE... 3 2. INQUADRAMENTO GEOLOGICO E GEOMORFOLOGICO... 4 3.CARATTERIZZAZIONE SISMICA DEL SITO... 12 INDICE 1. PREMESSE... 3 2. INQUADRAMENTO GEOLOGICO E GEOMORFOLOGICO... 4 3.CARATTERIZZAZIONE SISMICA DEL SITO... 12 2 1. PREMESSE La seguente relazione riporta le considerazioni svolte per la caratterizzazione

Dettagli

Dott. Bernardino Zavagnin Geologo

Dott. Bernardino Zavagnin Geologo 2 1. PREMESSA In via Terosse, in conseguenza all eccezionale piovosità dei mesi di gennaio e febbraio 2014, si è manifestato un cedimento della banchina stradale per una lunghezza di 50.0 m circa. L ubicazione

Dettagli

ALLEGATO 5 APPROFONDIMENTO SISMICO DI 2 LIVELLO

ALLEGATO 5 APPROFONDIMENTO SISMICO DI 2 LIVELLO ALLEGATO 5 APPROFONDIMENTO SISMICO DI 2 LIVELLO 1 PROCEDURE REGIONALI PER IL 2 LIVELLO DI APPROFONDIMENTO SISMICO SULLA BASE DEI CRITERI DELLA D.G.R. N. IX/2616/2011 La procedura di cui al punto 1.4.4

Dettagli

Parte I): Principi di Geotecnica

Parte I): Principi di Geotecnica Parte I): Principi di Geotecnica Principi di Geotecnica e di Tecnica delle Fondazioni 1 Generalità: Il terreno, le terre e le roccie La geotecnica non si occupa della rocce ma della meccanica dei terreni

Dettagli

Prontuario Opere Geotecniche (Norme tecniche per le costruzioni D.M. 14/01/2008)

Prontuario Opere Geotecniche (Norme tecniche per le costruzioni D.M. 14/01/2008) Prontuario Opere Geotecniche (Norme tecniche per le costruzioni D.M. 14/01/2008) Punto 6.2.3_Verifiche statiche: Stati Limite Ultimi (SLU) Stato Limite di resistenza del terreno (GEO) Stato Limite di resistenza

Dettagli

PROGETTO DEFINITIVO CAMPO IN ERBA SINTETICA DIMENSIONAMENTO DELLE STRUTTURE PRINCIPALI

PROGETTO DEFINITIVO CAMPO IN ERBA SINTETICA DIMENSIONAMENTO DELLE STRUTTURE PRINCIPALI COMUNE DI VALLI DEL PASUBIO REGIONE VENETO PROGETTO DEFINITIVO CAMPO IN ERBA SINTETICA DIMENSIONAMENTO DELLE STRUTTURE PRINCIPALI dott. ing. Giuseppe Piccioli Albo Ingegneri di Vicenza iscritto al n. 814

Dettagli

COMUNE DI SAVIGLIANO

COMUNE DI SAVIGLIANO REGIONE PIEMONTE PROVINCIA DI CUNEO COMUNE DI SAVIGLIANO Proponente: sig. DONALISIO Pietro Via Vezzolano 25-10153 Torino IMPIANTO IDROELETTRICO SUL T. MAIRA NEL COMUNE DI SAVIGLIANO CENTRALE SAN GIACOMO

Dettagli

eseguito in Comune di... Località.. Via... n.. CAP... Comune Catastale.. Foglio n. Mappale o Particella. DICHIARA

eseguito in Comune di... Località.. Via... n.. CAP... Comune Catastale.. Foglio n. Mappale o Particella. DICHIARA MODULO 9 DICHIARAZIONE / ASSEVERAZIONE DEL GEOLOGO DI CONGRUITA' DEI CONTENUTI DELLA RELAZIONE GEOLOGICA AI REQUISITI RICHIESTI DAL PUNTO 6.2.1 DELLE N.T.C. DM 14/01/08 e/o DALLA D.G.R. IX 2616/2011 Il

Dettagli

GEOLOGO DOTT. LORENZO SEDDA VIA C. COLOMBO 1/B/ AREZZO 0575/ /

GEOLOGO DOTT. LORENZO SEDDA VIA C. COLOMBO 1/B/ AREZZO 0575/ / GEOLOGO DOTT. LORENZO SEDDA VIA C. COLOMBO 1/B/2 52100 AREZZO 0575/906627 339/1443593 GEOLOGO DOTT. LORENZO SEDDA VIA C. COLOMBO 1/B/2 52100 AREZZO 0575/906627 339/1443593 2 GEOLOGO DOTT. LORENZO SEDDA

Dettagli

LA NORMATIVA SISMICA E LA MICROZONAZIONE SISMICA

LA NORMATIVA SISMICA E LA MICROZONAZIONE SISMICA LA NORMATIVA SISMICA E LA MICROZONAZIONE SISMICA L. 02/02/1974 n 64 Provvedimenti per le costruzioni con particolari prescrizioni per le zone sismiche : Criteri Generali La L. 64/74 fissa i principi generali

Dettagli

Categoria di suolo di fondazione = C

Categoria di suolo di fondazione = C Modello sismico di taglio (Vs) 100 200 300 400 500 600 700 800 900 0 5 10 Vs (m/s) V s30 =258 m/s classe C 15 profondità (m) 20 25 30 35 40 45 50 D C B A La Vs30 misurata è stata di: Vs30= 258 m/s ± 10

Dettagli

CITTÀ DI PIOSSASCO P.IVA

CITTÀ DI PIOSSASCO P.IVA CITTÀ DI PIOSSASCO C..A.P. 10045 PROVINCIA DI TORINO P.IVA 0161477001 ----------------------------------------- Tel. : 011/ 90.7.63-6 - Fax 011/ 90.7.69 REALIZZAZIONE NUOVI LOCULI LUNGO LA CINTA SUD DELL

Dettagli

P.R.U. PROGETTO CASA COMUNALE STATO DI PROGETTO. Città di San Benedetto del Tronto PROGRAMMA RIQUALIFICAZIONE URBANA. "PRU N.

P.R.U. PROGETTO CASA COMUNALE STATO DI PROGETTO. Città di San Benedetto del Tronto PROGRAMMA RIQUALIFICAZIONE URBANA. PRU N. P.R.U. Artt. 5 e 6 della L.R. 16 del 23.02.2005 PROGRAMMA RIQUALIFICAZIONE URBANA "PRU N.6" - Via Toscana Città di San Benedetto del Tronto P R O V I N C I A D I A S C O L I P I C E N O PROGETTO CASA COMUNALE

Dettagli

REGIONE PUGLIA PROVINCIA DI FOGGIA COMUNE DI PESCHICI

REGIONE PUGLIA PROVINCIA DI FOGGIA COMUNE DI PESCHICI REGIONE PUGLIA PROVINCIA DI FOGGIA COMUNE DI PESCHICI Oggetto: Lavori per la realizzazione delle costruzioni derivanti da volumi da demolire e delocalizzare nel P.I.R.T. Baia di Manaccora Stralcio 1 (Blocco

Dettagli

RISPOSTA SISMICA DI DEPOSITI DI TERRENO A GRANA GROSSA IN ALCUNE AREE DELLA TOSCANA

RISPOSTA SISMICA DI DEPOSITI DI TERRENO A GRANA GROSSA IN ALCUNE AREE DELLA TOSCANA FACOLTA DI INGEGNERIA 12 Aprile 2005 RISPOSTA SISMICA DI DEPOSITI DI TERRENO A GRANA GROSSA IN ALCUNE AREE DELLA TOSCANA Maurizio Ferrini*, Massimo Baglione*, Samuela Iacomelli**, *Regione Toscana - Settore

Dettagli

I N D I C E. 1 Premessa pag.2. 2 Normative pag.2. 3 Descrizione del fabbricato pag.2. 4 Materiali pag.3. 5 Dati di definizione pag.

I N D I C E. 1 Premessa pag.2. 2 Normative pag.2. 3 Descrizione del fabbricato pag.2. 4 Materiali pag.3. 5 Dati di definizione pag. I N D I C E 1 Premessa pag.2 2 Normative pag.2 3 Descrizione del fabbricato pag.2 4 Materiali pag.3 5 Dati di definizione pag.4 6 Azioni e carichi pag.4 1 1 Premessa La presente relazione ha per oggetto

Dettagli

REGIONE CAMPANIA COMUNE DI BASELICE. Provincia di Benevento LAVORI DI BONIFICA E MESSA IN SICUREZZA DELLA DISCARICA COMUNALE IN CONTRADA SERRE

REGIONE CAMPANIA COMUNE DI BASELICE. Provincia di Benevento LAVORI DI BONIFICA E MESSA IN SICUREZZA DELLA DISCARICA COMUNALE IN CONTRADA SERRE REGIONE CAMPANIA COMUNE DI BASELICE Provincia di Benevento LAVORI DI BONIFICA E MESSA IN SICUREZZA DELLA DISCARICA COMUNALE IN CONTRADA SERRE PROGETTO ESECUTIVO (Art. 33 D.P.R. 207/2010) RELAZIONE GEOTECNICA

Dettagli

con effetto di P.U.A.

con effetto di P.U.A. con effetto di P.U.A. RELAZIONE GEOLOGICA E SISMICA Adozione C.C. n. 51 del 05.08.2008 Approvazione C.C. n. 5 del 05.03.2009 o dr. geol. GIANLUCA CANTARELLI LOCALIZZAZIONE: Marzano (area 22) 1.- PREMESSA

Dettagli

ALLEGATO C Nuove classi di Rischio Geologico e indagini minime di tipo geologico, geofisico e geotecnico da eseguire

ALLEGATO C Nuove classi di Rischio Geologico e indagini minime di tipo geologico, geofisico e geotecnico da eseguire ALLEGATO C Nuove classi di Rischio Geologico e indagini minime di tipo geologico, geofisico e geotecnico da eseguire ai sensi del Regolamento Regionale n. 2/2012 La Relazione Geologica e di Modellazione

Dettagli

Lago Nero Report 2006

Lago Nero Report 2006 Lago Nero Report 2006 1.0 Premessa La presente relazione illustra i primi risultati di una campagna di indagini geognostiche eseguite in Località Lago Nero nel Comune di Tornareccio (CH), nell ambito del

Dettagli

RELAZIONE GEOLOGICA MODELLAZIONE SISMICA E RELAZIONE GEOTECNICA

RELAZIONE GEOLOGICA MODELLAZIONE SISMICA E RELAZIONE GEOTECNICA Studio Tecnico di Geologia Dott. Negri Giuseppe via Capodivilla 10 31053 Pieve di Soligo Tel 0.438 82910 cell 336 503969 e-mail negrigiuseppe1@virgilio.it RELAZIONE GEOLOGICA MODELLAZIONE SISMICA E RELAZIONE

Dettagli

Relazione di calcolo geotecnica. Parco Area delle Scienze PARMA - Tel. 0521/906218/19/20. Pag. 1

Relazione di calcolo geotecnica. Parco Area delle Scienze PARMA - Tel. 0521/906218/19/20. Pag. 1 U.O. SVILUPPO EDILIZIO Parco Area delle Scienze - 43100 PARMA - Tel. 051/90618/19/0 Pag. 1 INDICE 1. Premessa... 3. Calcolo della capacità portante delle colonne... 4.1 Colonne Ø600 e Ø800... 5 3. Verifica

Dettagli

ESEMPIO DI CALCOLO DI CAPACITA PORTANTE Rd in condizioni statiche e sismiche

ESEMPIO DI CALCOLO DI CAPACITA PORTANTE Rd in condizioni statiche e sismiche ESEMPIO DI CALCOLO DI CAPACITA PORTANTE Rd in condizioni statiche e sismiche 111 DH (m) Gam (kn/m³) Gams (kn/m³) Fi ( ) Fi Corr. ( ) c (kn/m²) c Corr. (kn/m²) cu (kn/m²) Ey (kn/m²) Ed (kn/m²) Ni Cv (cmq/s)

Dettagli

GEOLOGIA TECNICA ESTENSE STUDIO GEOLOGICO COMUNE DI JOLANDA DI SAVOIA

GEOLOGIA TECNICA ESTENSE STUDIO GEOLOGICO COMUNE DI JOLANDA DI SAVOIA GEOLOGIA TECNICA ESTENSE STUDIO GEOLOGICO Dr. Geol. Marco Condotta PROVINCIA DI FERRARA COMUNE DI JOLANDA DI SAVOIA Procedura congiunta di VIA e modifica sostanziale di AIA per il progetto di completamento

Dettagli

RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE

RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE RELAZIONE ILLUSTRATIVA RIGUARDANTE LE STRUTTURE Proprietà: Ubicazione: RONCONI & LIVERANI Srl Comune di Cotignola Via Madonna di Genova n 39/41 Prog. e DDL Strutturale: Progetto architettonico: Ing. Peroni

Dettagli

RELAZIONE GEOLOGICA E RELAZIONE GEOTECNICA

RELAZIONE GEOLOGICA E RELAZIONE GEOTECNICA Dott. PIETRO ALBORGHETTI Geologo Consulenze geologiche, geotecniche, idrogeologiche ed ambientali Provincia di Lecco Comune di Valgreghentino PROGETTO DEFINITIVO-ESECUTIVO FORMAZIONE NUOVI LOCULI NEL CIMITERO

Dettagli

RELAZIONE GEOTECNICA REALIZZAZIONE DELLE INFRASTRUTTURE COMUNALE PER L INSEDIAMENTO DEL TECNOPOLO NELL AREA DENOMINATA EX MACELLO

RELAZIONE GEOTECNICA REALIZZAZIONE DELLE INFRASTRUTTURE COMUNALE PER L INSEDIAMENTO DEL TECNOPOLO NELL AREA DENOMINATA EX MACELLO RELAZIONE GEOTECNICA REALIZZAZIONE DELLE INFRASTRUTTURE PER L INSEDIAMENTO DEL TECNOPOLO NELL AREA DENOMINATA EX MACELLO COMUNALE Relazione Geotecnica Infrastrutture TECNOPOLO- pag. 1/11 RELAZIONE GEOTECNICA

Dettagli

Cartografia geologica e microzonazione sismica

Cartografia geologica e microzonazione sismica Sala A conferenze, Terza Torre - 19 aprile 12 MICROZONAZIONE SISMICA UNO STRUMENTO CONSOLIDATO PER LA RIDUZIONE DEL RISCHIO L esperienza della Regione Emilia-Romagna Cartografia geologica e microzonazione

Dettagli

COMUNE DI TARANTO RELAZIONE SULLA MODELLAZIONE SISMICA

COMUNE DI TARANTO RELAZIONE SULLA MODELLAZIONE SISMICA Dott. Geol. Jean Vincent C.A. Stefani C.da Saponaro 70, 74023 Grottaglie (TA) Tel. 099.5610224 cell. 3388641493 Fax 099.5610224 E-mail stefani.geologo@libero.it COMUNE DI TARANTO RELAZIONE SULLA MODELLAZIONE

Dettagli

Progr. n A2.1 - Tabelle per il calcolo dei coefficienti di amplificazione sismica (secondo livello di approfondimento)

Progr. n A2.1 - Tabelle per il calcolo dei coefficienti di amplificazione sismica (secondo livello di approfondimento) Progr. n. 112 21 ALLEGAO A2 ABELLE E FORMULE PER LA VALUAZIONE DEI FAORI DI AMPLIFICAZIONE SISMICA PER LE ANALISI DEL SECONDO LIVELLO DI APPROFONDIMENO E PER LA VALUAZIONE DEGLI EFFEI OPOGRAFICI. A2.1

Dettagli

RELAZIONE DI CALCOLO

RELAZIONE DI CALCOLO COMUNE di INDUNO OLONA - PROVINCIA DI VARESE PROGETTO di AMPLIAMENTO del CIMITERO COMUNALE PROGETTO STRUTTURALE ESECUTIVO RELAZIONE DI CALCOLO Brescia, 20 Ottobre 2011 1 Il dimensionamento e le verifiche

Dettagli

ASPETTI LEGATI ALLA RESISTENZA IN PRESENZA DI AZIONI SISMICHE. R.Berardi-Progettazione Geotecnica nella Difesa del S uolo

ASPETTI LEGATI ALLA RESISTENZA IN PRESENZA DI AZIONI SISMICHE. R.Berardi-Progettazione Geotecnica nella Difesa del S uolo ASPETTI LEGATI ALLA RESISTENZA IN PRESENZA DI AZIONI SISMICHE 1 Parametri geotecnici da NTC 2008 Nei terreni saturisi assumono generalmente condizioni di drenaggio impedito. In tal caso, nelle analisi

Dettagli