PROTOCOLLO MODBUS RTU

Documenti analoghi
PROTOCOLLO MODBUS RTU

NOTA TECNICA By6150-S-485 Comunicazioni MODBUS J BUS

EML-16 EML-16. Pulses concentrator. Concentratore impulsi MODBUS COMMUNICATION PROTOCOL PROTOCOLLO DI COMUNICAZIONE MODBUS

IM-IU v0.1. alternata e continua. pag. 1 / 5

Capitolo 8 - Protocollo Modbus RTU per Drive SIRCO

CONFIGURATION MANUAL

PROTOCOLLO DI COMUNICAZIONE MODBUS MODBUS COMMUNICATION PROTOCOL. MANUALE ISTRUZIONI / INSTRUCTION MANUAL IM163-IU v0.61

EMS_ _Interface_ModbusTable_LG_EN_v1.00.xlsx

Il protocollo MODBUS. Il protocollo MODBUS Pag. 1 di 11

Code: GW-IMP-WEB-1. Datalogger web pulses counter. Version 6 inputs with Ethernet. MarCom

REGISTRATION GUIDE TO RESHELL SOFTWARE

EMS_ _State_GenericInput_ModbusTable_LG_EN_v1.00.xlsx

0x03 (Read Holding Registers) 0x06 (Write Single Register)

Test di comunicazione tra due LOGO! 0BA7: Master - Master

Modulo plug&play MKMB-3-e-3. Interfaccia Modbus/RTU per contatori Iskraemeco MT831 / MT860

Guida alla configurazione Configuration Guide

Blocchi funzione: FbModbusAsciiMs

Contatore d impulsi S0

CONVERTITORE DI MISURA DI CORRENTE o TENSIONE o FREQUENZA o POTENZA VERO VALORE EFFICACE MONOFASE ALIMENTAZIONE SEPARATA MONTAGGIO GUIDA DIN

DICHIARAZIONE DI RESPONSABILITÀ

Gateway Bacnet Multichiller series

Collegamento di processori PLC-5 e SLC tramite rete DH+ Utilizzando processori SLC 5/04

SUITE BY GSM Direct Monitor

Attuatore a relè Manuale di istruzioni

Attuatore a relè Manuale di istruzioni

ISTRUZIONI PER L'UTILIZZO DEL PROTOCOLLO MODBUS

MANUALE UTENTE PEL 2500 / PEL 2500-M V2.0.0 ( ) 1 (7)

Schede di espansione per Hi-drive: Profibus. Expansion cards for Hi-drive: Profibus

Gateway Bacnet Multichiller series

Configurazione moduli I/O serie EX

ENERGY METER MOD.320C Energy Meter Din Rail per sistemi elettrici monofase

Interfaccia BL232 con uscite RS232/422/485 MODBUS e 0-10V. Interfaccia BL232

Guida utente User Manual made in Italy Rev0

FTP NAV - Guida tecnica FTP NAV - Technical Guide

Indirizzi MODBUS per ETH Mar 2012

INSTALLARE PALLADIO USB DATA CABLE IN WINDOWS XP/ME/2000/98

Radio Frequency Identification Systems

Iptables. Mauro Piccolo

MODBUS-RTU per. Specifiche protocollo di comunicazione MODBUS-RTU per controllo in rete dispositivi serie. Expert NANO 2ZN

Parte 1. Vettori di bit - AA. 2012/13 1.1

Assembler di Spim. Assembler di SPIM. Struttura di un programma assembler. Direttive

BY Sistema di Protezione Interfaccia CEI 0-21

CANUSB. Programmable CAN bus-pc interface

CANPC-S1. Programmable CanBus-PC interface

Part. Y1792A - 06/06-01 PC. Protocollo di comunicazione seriale Modbus

CONTABILIZZATORE DI IMPULSI MONTAGGIO GUIDA DIN

Posta elettronica per gli studenti for the students

TNCguide OEM Informativa sull introduzione di documentazione aggiuntiva nella TNCguide

CUSTOMER SERVICE GPS/ RADIOTRACKING DOG COLLAR. T. (+34) F. (+34)

Portale Materiali Grafiche Tamburini. Grafiche Tamburini Materials Portal

SIEMENS GIGASET S450 IP GUIDA ALLA CONFIGURAZIONE EUTELIAVOIP

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

Descrizione del protocollo

Come si può vedere, la regola è stata fatta in modo da spostare tutti i messaggi di Spam nella cartella del cestino.

KEYSTONE. OM8 - EPI 2 Modulo interfaccia AS-i Manuale di istruzione. Indice 1 Modulo Opzionale OM8: Interfaccia AS-i 1

Enhanced Write Filter

Xenon 1900/1910. Guida introduttiva. Area Imager con cavo. NG2D-IT-QS Rev D 10/12

Lezione 1: L architettura LC-3 Laboratorio di Elementi di Architettura e Sistemi Operativi 10 Marzo 2014

Manuale di Aggiornamento BOLLETTINO. Rel H4. DATALOG Soluzioni Integrate a 32 Bit

SUITE BY Pannello Misure BY11250

4 3 4 = 4 x x x 10 0 aaa

ED To communicate with the DP module will need to configure the serial port s parameters of the PC/PLC as it follows:

Dispositivo Modbus. Manuale di installazione e uso. Doc Rev.1 (03/15)

Gateway RS485 DLMS-MODBUS. Dispositivo di Comunicazione tra DLMS RS485 e MODBUS RTU e/o MODBUS TCP

AMICA Antarctic Multiband Infrared CAmera

Sistema Operativo di un Router (IOS Software)

Access Control List (I parte)

cej_ed Yedjhebb[h MODBUS Device interno Device interno - MODBUS Aggiornato il: 26/02/07

Introduzione Kerberos. Orazio Battaglia

VNET HOP Hw code 2248 Rev. 0. VNET 433 Hw code 2235 Rev. 2. VNET 433 FLEX Hw code 2274 Rev. 0. VNET LP Hw code 2247 Rev. 0

quick guide guida rapida J.touch hydromassage bath remote control telecomando per vasche idromassaggio

Arduino: Programmazione

User s Manual Modbus Protocol

EFA Automazione S.r.l. Serial Bridge 3 - Modbus RTU slave to EIB (01 ITA).doc pag. 1 / 9

EFA Automazione S.r.l. Serial Bridge 3 - Modbus RTU slave to Technolife (01 ITA).doc pag. 1 / 9

1. Soluzione esercizio XYZ SpA

MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS

Reti e Sistemi per l Automazione MODBUS. Stefano Panzieri Modbus - 1

WELCOME. Go to the link of the official University of Palermo web site Click on the box on the right side Login unico

IBM SPSS Statistics per Windows - Istruzioni di installazione (Licenza di rete)

GUIDA ALL'INSTALLAZIONE PER NOKIA NETWORK BRIDGE. Copyright 2004 Nokia. Tutti i diritti sono riservati. 1/6

FGCAEN Demo software per Mac OS X Leopard ) Lancio dell applicazione. 2) Apertura della comunicazione seriale

Granit 1910i. Guida introduttiva. Lettore industriale area imager. GRNT-IT-QS Rev A 10/12

3URWRFROOR0RGEXVSHUS&2ñ0RGEXVSURWRFROIRUS&2ð 0DQXDOHG XVR 8VHUPDQXDO

Istruzioni per la gestione della password

Manuale di programmazione BerMar_Drive_Software

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

Ruolo delle associazioni di impresa nella informazione corretta sui pericoli da sostanze e miscele

You can visualize the free space percentage in Compact Flash memory from the MENU/INFO C.F. UTILITY-FREE SPACE page.

Manuale del portale di back office di MonetaWeb

BMSO1001. Virtual Configurator. Istruzioni d uso 02/10-01 PC

Configurazione di I/O complementari per i processori PLC-5 (Numero di catalogo della serie 1785)

Protocolli di Comunicazione Elettronica dei Sistemi Digitali L-A Università di Bologna, Cesena

A. Carullo Introduzione a Visual Basic. Introduzione a

Guida Rapida all uso del License Manager di ROCKEY4Smart (V )

= 1*2^7 + 1*2^6 + 0*2^5 + 1*2^4 + 0*2^3 + 0*2^2 + 1*2^1 + 0*2^0 = 210

Logica e codifica binaria dell informazione

Schedulazione dinamica. Elettronica dei Calcolatori 1

Come usare P-touch Transfer Manager

Transcript:

Progettato e prodotto interamente in Italia CONTABILIZZATORE DI IMPULSI MONTAGGIO GUIDA DIN PROTOCOLLO MODBUS RTU Il protocollo di comunicazione è MODBUS, conforme alle specifiche Modbus Application Protocol Specification V1.1A Jun 04 2004 e l interfaccia Hardware è RS485. Il node address può essere scelto tra 1 e 255. 1. Parametri di comunicazione I parametri di comunicazione sono riassunti nella seguente tabella. Parametro Impostazione Baud rate 9600 19200 38400 57600 115200 Parità Nessuna (N) Bit di dati 8 Bit di stop 1 2. Function Codes Sono implementati solo 3 function codes: 0x03 (Read Holding Registers)... 0x04 (Read Input Registers)... 0x06 (Write Single Register)... I function codes sono pienamente supportati dai relativi Error Codes ed Exception Codes. 3. Struttura Ci sono 3 aree dati: Registri WO (Write Only). I registri definiti WO si possono solo scrivere (con un dato congruentemente previsto), ottenedo la risposta dell esito dell operazione subito dopo il tentativo di scrittura. Registri RW (Read/Write). I registri definiti RW, si possono sia leggere che scrivere. Registri RO (Read Only). I registri definiti RO si possono solo leggere. 4. Lettura La lettura è permessa sui registri RW ed RO indifferentemente sia come Holding(03) che come Input(04) registers: <node_address>,03,<start_addr_h>,<start_addr_l>,00,<nn>,<crc_l>,<crc_h> <node_address>,04,<start_addr_h>,<start_addr_l>,00,<nn>,<crc_l>,<crc_h> UG_X_10600_ModbusCommunication_01_IE.docx 1/10

Dove: <node_address> è il numero di nodo della scheda. <nn> è il numero di registri consecutivi a partire da <Start_Addr_L> compreso, e deve essere compreso tra 1 e (<Max_Addr_L> - <Start_Addr_L>) + 1. La risposta corretta, a seconda del comando usato, è la seguente: <node_address>,03,<bb>,<reg_val_h>,<reg_val_l>,<crc_l>,<crc_h> <node_address>,04,<bb>,<reg_val_h>,<reg_val_l>,<crc_l>,<crc_h> <bb> è il numero di BYTES effettivamente risposto. La risposta associata in caso di errore è la seguente: <node_address>,83,<exception_code>,<crc_l>,<crc_h> <node_address>,84,<exception_code>,<crc_l>,<crc_h> L Exception Code è compreso tra 01 e 04, in accordo con le specifiche 1.1A, pag. 49 di 51. 5. Scrittura La scrittura è permessa sui registri WO e RW solo come Single Register(06) registers: <node_add>,06,<addr_h>,<addr_l>,<data_h>,<data_l>,<crc_l>,<crc_h> Dove: <node_address> è il numero di nodo della scheda. <Addr_H,L> è l indirizzo del registro e <Data_H,L> è il dato da scrivere. Se il dato è accettato, la strumento risponde con lo stesso telegramma di scrittura. La risposta in caso di errore è la seguente: <node_address>,86,<exception_code>,<crc_l>,<crc_h> L Exception Code è compreso tra 01 e 04, in accordo con le specifiche 1.1A, pag. 49 di 51. PASSWORD Tra i registri WO, è presente il registro PASSWORD. Prima di qualsiasi operazione di scrittura, bisogna scrivere il valore corretto di password su questo registro, per abilitare la scrittura di tutti gli altri parametri. Questa abilitazione alla scrittura apre una finestra di tempo di qualche secondo, entro la quale si devono eseguire le scritture dei registri desiderati (compreso lo stesso registro PASSWORD, per la sua modifica). Se l operazione risulta troppo lunga per essere eseguita in questo tempo, bisogna inviare ancora il codice password e proseguire con le scritture mancanti. Ripetere fino a quando è necessario. ATTENZIONE: A protezione del codice password, al PRIMO tentativo errato interviene un BLOCCO della scrittura, che dura parecchi minuti. Questo tempo non è in nessun modo azzerabile (nemmeno spegnendo il dispositivo che, al contrario lo riporta al massimo) UG_X_10600_ModbusCommunication_01_IE.docx 2/10

Legenda: INDIRIZZO = Numero del registro modbus [.Bit del registro]. Quando il registro contiene un valore numerico, il suo indirizzo è INTERO. Quando invece contiene il valore boleano di un suo specifico bit (flag), il bit deve è individuato dal punto seguito dal suo valore posizionale 0-15 a partire da destra. (es. 258.10 indica l'undicesimo bit del registro 258). TIPO = BBBB - BB - Bb -bb. Identificatore di gestione registro composito (32bit), registro intero a 16bit oppure semi-registro (8 bit). Con BBBB si vuole indicare un valore da ricavare da 2 registri consecutivi, la cui parte alta è all'indirizzo indicato, seguita immediatamente all indirizzo+1 dalla bassa. Con BB si vuole indicare un valore da ricavare dall'intero registro (16bit). Con Bb si vuole indicare un valore ad 8 bit contenuto nella metà alta del registro. Con bb invece un valore ad 8 bit contenuto nella metà bassa del registro. FORMATO = DEC - DECS - BOL - HEX - BCD. Il valore binario a 32, 16 o 8 bit deve essere convertito in: DEC = Valore decimale senza segno DECS = Valore decimale con segno BOL = Valore Vero o Falso del bit specificato nell argomento indirizzo HEX = Valore BCD = Un carattere 0-9 ogni 4 bit PERMESSI = RO RW - WO permessi da remoto. Con RO non è permesso cambiare il valore del registro. Con RW è permesso cambiare il valore del registro, usando il comando di write. Con WO è permesso scrivere il valore del registro, usando il comando di write, ma non di leggerlo (modalità invio comandi - il registro fisico non esiste). FATTORE = DM - D - C - M - N posizione virgola. Ha senso solo in formati Decimali (DEC o DECS). Con N, la cifra decimale rimane intera. Con D, il valore è da intendersi moltiplicato per 0,1. Con C, il valore è da intendersi moltiplicato per 0,01. Con M, il valore è da intendersi moltiplicato per 0,001 Con DM, il valore è da intendersi moltiplicato per 0,0001. REGISTRI WO (WRITE ONLY) INDIRIZZO TIPO DESCRIZIONE FORMATO U.M. PERMESSI FATTORE NOTE 0 bb Riservato DEC WO N 1 BB PASSWORD DEC WO N UG_X_10600_ModbusCommunication_01_IE.docx 3/10

REGISTRI RW (READ/WRITE) INDIRIZZO TIPO DESCRIZIONE FORMATO U.M. PERMESSI FATTORE NOTE 256.0 BB FLAG RISERVATO BOL RW N 256.1 BB FLAG RISERVATO BOL RW N 256.2 BB FLAG RISERVATO BOL RW N 256.3 BB FLAG RISERVATO BOL RW N 256.4 BB FLAG RISERVATO BOL RW N 256.5 BB FLAG RISERVATO BOL RW N 256.6 BB FLAG RISERVATO BOL RW N 256.7 BB FLAG RISERVATO BOL RW N 256.8 BB FLAG RISERVATO BOL RW N 256.9 BB FLAG RISERVATO BOL RW N 256.10 BB FLAG RISERVATO BOL RW N 256.11 BB FLAG RISERVATO BOL RW N 256.12 BB FLAG RISERVATO BOL RW N 256.13 BB FLAG RISERVATO BOL RW N 256.14 BB FLAG RISERVATO BOL RW N 256.15 BB FLAG RISERVATO BOL RW N 257 bb BPS DEC RW N (0=9600-1=19200-2=38400-3=57600-4=115200) 258.0 bb 1 = Ing 1 NC ( 0 = NO) BOL RW N 258.1 bb 1 = Ing 2 NC ( 0 = NO) BOL RW N 258.2 bb 1 = Ing 3 NC ( 0 = NO) BOL RW N 258.3 bb 1 = Ing 4 NC ( 0 = NO) BOL RW N 258.4 bb 1 = Ing 5 NC ( 0 = NO) BOL RW N 259 BBBB TOTALIZZATORE 1 DEC RW N 261 BBBB TOTALIZZATORE 2 DEC RW N 263 BBBB TOTALIZZATORE 3 DEC RW N 265 BBBB TOTALIZZATORE 4 DEC RW N 267 BBBB TOTALIZZATORE 5 DEC RW N 269.0 bb 1=OVERLOAD ERROR 1 BOL RW N 269.1 bb 1=OVERLOAD ERROR 2 BOL RW N 269.2 bb 1=OVERLOAD ERROR 3 BOL RW N 269.3 bb 1=OVERLOAD ERROR 4 BOL RW N 269.4 bb 1=OVERLOAD ERROR 5 BOL RW N 270.0 bb 1=Misura 1 abilitata BOL RW N 270.1 bb 1=Misura 2 abilitata BOL RW N 270.2 bb 1=Misura 3 abilitata BOL RW N 270.3 bb 1=Misura 4 abilitata BOL RW N 270.4 bb 1=Misura 5 abilitata BOL RW N 271 BBBB Misura Linea 1 - INTERA DEC RW N 273 BB Misura Linea 1 - DEC DEC RW DM 274 BBBB Misura Linea 2 - INTERA DEC RW N 276 BB Misura Linea 2 - DEC DEC RW DM 277 BBBB Misura Linea 3 - INTERA DEC RW N 279 BB Misura Linea 3 - DEC DEC RW DM 280 BBBB Misura Linea 4 - INTERA DEC RW N 282 BB Misura Linea 4 - DEC DEC RW DM 283 BBBB Misura Linea 5 - INTERA DEC RW N 285 BB Misura Linea 5 - DEC DEC RW DM 286 bb Tempo filtro Linea 1 DEC msec RW D 287 bb RISERVATO 1 DEC RW N 288.0 bb 1 = TOTALIZZ 1 NO Roll BOL RW N 288.1 bb 1 = Misura 1 NO Roll BOL RW N 288.2 bb 1 = TOTALIZZ 1 NO Memo BOL RW N 288.3 bb 1 = Misura 1 NO Memo BOL RW N 289 BB Peso IMP 1 INTERO DEC RW N 290 BB Peso IMP 1 DEC DEC RW DM 291 bb Tempo filtro Linea 2 DEC msec RW D 292 bb RISERVATO 2 DEC RO N 293.0 bb 1 = TOTALIZZ 2 NO Roll BOL RW N 293.1 bb 1 = Misura 2 NO Roll BOL RW N 293.2 bb 1 = TOTALIZZ 2 NO Memo BOL RW N 293.3 bb 1 = Misura 2 NO Memo BOL RW N UG_X_10600_ModbusCommunication_01_IE.docx 4/10

INDIRIZZO TIPO DESCRIZIONE FORMATO U.M. PERMESSI FATTORE NOTE 294 BB Peso IMP 2 INTERO DEC RW N 295 BB Peso IMP 2 DEC DEC RW DM 296 bb Tempo filtro Linea 3 DEC msec RW D 297 bb RISERVATO 3 DEC RW N 298.0 bb 1 = TOTALIZZ 3 NO Roll BOL RW N 298.1 bb 1 = Misura 3 NO Roll BOL RW N 298.2 bb 1 = TOTALIZZ 3 NO Memo BOL RW N 298.3 bb 1 = Misura 3 NO Memo BOL RW N 299 BB Peso IMP 3 INTERO DEC RW N 300 BB Peso IMP 3 DEC DEC RW DM 301 bb Tempo filtro Linea 4 DEC msec RW D 302 bb RISERVATO 4 DEC RW N 303.0 bb 1 = TOTALIZZ 4 NO Roll BOL RW N 303.1 bb 1 = Misura 4 NO Roll BOL RW N 303.2 bb 1 = TOTALIZZ 4 NO Memo BOL RW N 303.3 bb 1 = Misura 4 NO Memo BOL RW N 304 BB Peso IMP 4 INTERO DEC RW N 305 BB Peso IMP 4 DEC DEC RW DM 306 bb Tempo filtro Linea 5 DEC msec RW D 307 bb RISERVATO 5 DEC RW N 308.0 bb 1 = TOTALIZZ 5 NO Roll BOL RW N 308.1 bb 1 = Misura 5 NO Roll BOL RW N 308.2 bb 1 = TOTALIZZ 5 NO Memo BOL RW N 308.3 bb 1 = Misura 5 NO Memo BOL RW N 309 BB Peso IMP 5 INTERO DEC RW N 310 BB Peso IMP 5 DEC DEC RW DM REGISTRI RO (READ ONLY) INDIRIZZO TIPO DESCRIZIONE FORMATO U.M. PERMESSI FATTORE NOTE 512 Bb Famiglia DEC RO N 512 bb Tipo Strumento DEC RO N 513 Bb Versione DEC RO N 513 bb Revisione DEC RO N 514 bb Timer BLOCCO Password ErrataDEC min RO N 515 bb Timer Permesso Scrittura DEC sec RO D 516.0 bb 1=Scrittura abilitata BOL RO N 516.1 bb 1=Blocco password errata BOL RO N 516.2 bb 1=Espansione BOL RO N 516.3 bb 1=Espansione BOL RO N 516.4 bb 1=Espansione BOL RO N 516.5 bb 1=Espansione BOL RO N 516.6 bb 1=Espansione BOL RO N 516.7 bb 1=Espansione BOL RO N Risoluzione problemi Il sistema NON risponde solo in 3 casi: 1. Hardware Failure (collegamenti errati, scheda spenta, guasto hardware,...) 2. Il Node Address non è quello della scheda 3. Il CRC del telegramma è errato. La presente guida ha scopo puramente informativo. Il costruttore si riserva il diritto di modificare e/o aggiornare il prodotto e la guida senza alcuna limitazione e senza obblighi di preavviso. Il costruttore non risponde di eventuali danni, diretti o indiretti, causati a persone o cose da avarie del prodotto o conseguenti la forzata sospensione dell uso dello stesso. UG_X_10600_ModbusCommunication_01_IE.docx 5/10

Designed and manufactured entirely in Italy PULSE METER DIN RAIL MOUNTING MODBUS RTU PROTOCOL The communication protocol is MODBUS RTU according to Modbus Application Protocol Specification V1.1A Jun 04 2004 and the hardware interface is RS485. The node address can be selected amoung 1 and 255. 1. Communication Parameters According to the following table. Parameter Settings Baud rate 9600 19200 38400 57600 115200 Parity None (N) Data Bit 8 Stop Bit 1 2. Function Codes 3 function codes available: 0x03 (Read Holding Registers)... 0x04 (Read Input Registers)... 0x06 (Write Single Register)... Error Codes and Exception Codes had been implemented. 3. Memory organization 3 data areas: WO Registers (Write Only). Registers which can be written only (with suitable data). The device supplies an answer telegram after performing the operation. RW Registers (Read/Write). Registers which can be written and read. RO Registers (Read Only). Registers which can be read only. 4. Reading (Data acquisition) RW and RO registers can be read as Holding(03) as Input(04) registers: <node_address>,03,<start_addr_h>,<start_addr_l>,00,<nn>,<crc_l>,<crc_h> <node_address>,04,<start_addr_h>,<start_addr_l>,00,<nn>,<crc_l>,<crc_h> Dove: UG_X_10600_ModbusCommunication_01_IE.docx 6/10

<node_address> device node address. <nn> amount of consecutive registers starting from <Start_Addr_L> (included). Any value in the range [1 ; (<Max_Addr_L> - <Start_Addr_L>) + 1]. The right answer telegram, in accordante with the function code used, is the following: <node_address>,03,<bb>,<reg_val_h>,<reg_val_l>,<crc_l>,<crc_h> <node_address>,04,<bb>,<reg_val_h>,<reg_val_l>,<crc_l>,<crc_h> <bb> amount of DATA BYTES. In case of error the answer telegram is: <node_address>,83,<exception_code>,<crc_l>,<crc_h> <node_address>,84,<exception_code>,<crc_l>,<crc_h> Exception Code is in the range [01 ; 04] according to specification document (see 1.1A, pag. 49 of 51). 5. Writing (Data Set) WO and RW registers can be written as Single Register(06): <node_add>,06,<addr_h>,<addr_l>,<data_h>,<data_l>,<crc_l>,<crc_h> with: <node_address> device node address. <Addr_H,L> register address <Data_H,L> data. If data is correct then the answer telegram is the same. In case of error the answer telegram is: <node_address>,86,<exception_code>,<crc_l>,<crc_h> Exception Code is in the range [01 ; 04] according to specification document (see 1.1A, pag. 49 of 51). PASSWORD The PASSWORD register is a WO register. You need to set the right password to this register in order to enable the setting of any other parameter otherwise no writing operation will be accepted. After setting the right password you have just few seconds to perform setting operations (included the PASSWORD register itself). If you go out of time you need to re-enter the password again. NOTE: if you enter the wrong password, further settings will be disabled for a long period. Switching off the device won t reset this time, on the contrary it will start again from scratch. UG_X_10600_ModbusCommunication_01_IE.docx 7/10

Keys: ADDRESS = Modbus register ID [.Bit of the register]. For a numeric value the address is an INTEGER. For a boolean value of a particolar bit of the register, the bit can be specified by its position (0-15) starting from the right side (ex: 258.10 is the 11th bit of the 258 register) TYPE = BBBB - BB - Bb -bb. Double register (32bits), Integer register (16bits) or half regsiter (8 bits). BBBB means a value which takes 2 consecutive registers (32bits) in the form high part low part BB means a value which takes the whole register (16bits). Bb means the half-high part (8bits) of the register Bb. bb means the half-low part (8bits) of the register bb. FORMAT = DEC - DECS - BOL - HEX - BCD. Il the value (32 or 16 bits) must be converted in: DEC = decimal value, unsigned DECS = decimal value, signed BOL = true or false HEX = raw value (hexadecimal) BCD = a charachter from 0 to 9 every 4 bits AUTHORIZATION = RO RW - WO remote authorization RO: the value can t be changed. RW: the value can be changed with the write command. WO: the value can be changed with the write command but can t be read. DECIMALS = DM - D - C - M - N decimal separator position (only for DEC or DECS formats. N, no decimal separator. D, 1 decimal (multiply by 0.1). C, 2 decimals (multiply by 0.01). M, 3 decimals (multiply by 0.001) DM, 4 decimals (multiply by 0.0001). WO REGISTERS (WRITE ONLY) ADDRESS TYPE DESCRIPTION FORMAT U.M. AUTH. DECIMALS NOTES 0 bb Reserved DEC WO N 1 BB PASSWORD DEC WO N UG_X_10600_ModbusCommunication_01_IE.docx 8/10

RW REGISTERS (READ/WRITE) ADDRESS TYPE DESCRIPTION FORMAT U.M. AUTH. DECIMALS NOTES 256.0 BB RESERVED FLAG BOL RW N 256.1 BB RESERVED FLAG BOL RW N 256.2 BB RESERVED FLAG BOL RW N 256.3 BB RESERVED FLAG BOL RW N 256.4 BB RESERVED FLAG BOL RW N 256.5 BB RESERVED FLAG BOL RW N 256.6 BB RESERVED FLAG BOL RW N 256.7 BB RESERVED FLAG BOL RW N 256.8 BB RESERVED FLAG BOL RW N 256.9 BB RESERVED FLAG BOL RW N 256.10 BB RESERVED FLAG BOL RW N 256.11 BB RESERVED FLAG BOL RW N 256.12 BB RESERVED FLAG BOL RW N 256.13 BB RESERVED FLAG BOL RW N 256.14 BB RESERVED FLAG BOL RW N 256.15 BB RESERVED FLAG BOL RW N 257 bb BPS DEC RW N (0=9600-1=19200-2=38400-3=57600-4=115200) 258.0 bb 1 = Ing 1 NC ( 0 = NO) BOL RW N 258.1 bb 1 = Ing 2 NC ( 0 = NO) BOL RW N 258.2 bb 1 = Ing 3 NC ( 0 = NO) BOL RW N 258.3 bb 1 = Ing 4 NC ( 0 = NO) BOL RW N 258.4 bb 1 = Ing 5 NC ( 0 = NO) BOL RW N 259 BBBB TOTALIZZATOR 1 DEC RW N 261 BBBB TOTALIZZATOR 2 DEC RW N 263 BBBB TOTALIZZATOR 3 DEC RW N 265 BBBB TOTALIZZATOR 4 DEC RW N 267 BBBB TOTALIZZATOR 5 DEC RW N 269.0 bb 1=OVERLOAD ERROR 1 BOL RW N 269.1 bb 1=OVERLOAD ERROR 2 BOL RW N 269.2 bb 1=OVERLOAD ERROR 3 BOL RW N 269.3 bb 1=OVERLOAD ERROR 4 BOL RW N 269.4 bb 1=OVERLOAD ERROR 5 BOL RW N 270.0 bb 1=Measure 1 enabled BOL RW N 270.1 bb 1=Measure 2 enabled BOL RW N 270.2 bb 1=Measure 3 enabled BOL RW N 270.3 bb 1=Measure 4 enabled BOL RW N 270.4 bb 1=Measure 5 enabled BOL RW N 271 BBBB Measure Ch1 - INT PART DEC RW N 273 BB Measure Ch1 - DEC PART DEC RW DM 274 BBBB Measure Ch2 - INT PART DEC RW N 276 BB Measure Ch2 - DEC PART DEC RW DM 277 BBBB Measure Ch3 - INT PART DEC RW N 279 BB Measure Ch3 - DEC PART DEC RW DM 280 BBBB Measure Ch4 - INT PART DEC RW N 282 BB Measure Ch4 - DEC PART DEC RW DM 283 BBBB Measure Ch5 - INT PART DEC RW N 285 BB Measure Ch5 - DEC PART DEC RW DM 286 bb Filter Ch1 (time) DEC msec RW D 287 bb RESERVED 1 DEC RW N 288.0 bb 1 = TOTALIZ 1 NO Roll BOL RW N 288.1 bb 1 = Measure 1 NO Roll BOL RW N 288.2 bb 1 = TOTALIZ 1 NO Memo BOL RW N 288.3 bb 1 = Measure 1 NO Memo BOL RW N 289 BB Weight IMP 1 INT PART DEC RW N 290 BB Weight IMP 1 DEC PART DEC RW DM 291 bb Filter Ch2 (time) DEC msec RW D 292 bb RESERVED 2 DEC RO N 293.0 bb 1 = TOTALIZ 2 NO Roll BOL RW N 293.1 bb 1 = Measure 2 NO Roll BOL RW N 293.2 bb 1 = TOTALIZ 2 NO Memo BOL RW N 293.3 bb 1 = Measure 2 NO Memo BOL RW N UG_X_10600_ModbusCommunication_01_IE.docx 9/10

ADDRESS TYPE DESCRIPTION FORMAT U.M. AUTH. DECIMALS NOTES 294 BB Weight IMP 2 INT PART DEC RW N 295 BB Weight IMP 2 DEC PART DEC RW DM 296 bb Filter Ch3 (time) DEC msec RW D 297 bb RESERVED 3 DEC RW N 298.0 bb 1 = TOTALIZ 3 NO Roll BOL RW N 298.1 bb 1 = Measure 3 NO Roll BOL RW N 298.2 bb 1 = TOTALIZ 3 NO Memo BOL RW N 298.3 bb 1 = Measure 3 NO Memo BOL RW N 299 BB Weight IMP 3 INT PART DEC RW N 300 BB Weight IMP 3 DEC PART DEC RW DM 301 bb Filter Ch4 (time) DEC msec RW D 302 bb RESERVED 4 DEC RW N 303.0 bb 1 = TOTALIZ 4 NO Roll BOL RW N 303.1 bb 1 = Measure 4 NO Roll BOL RW N 303.2 bb 1 = TOTALIZ 4 NO Memo BOL RW N 303.3 bb 1 = Measure 4 NO Memo BOL RW N 304 BB Weight IMP 4 INT PART DEC RW N 305 BB Weight IMP 4 DEC PART DEC RW DM 306 bb Filter Ch5 (time) DEC msec RW D 307 bb RESERVED 5 DEC RW N 308.0 bb 1 = TOTALIZ 5 NO Roll BOL RW N 308.1 bb 1 = Measure 5 NO Roll BOL RW N 308.2 bb 1 = TOTALIZ 5 NO Memo BOL RW N 308.3 bb 1 = Measure 5 NO Memo BOL RW N 309 BB Weight IMP 5 INT PART DEC RW N 310 BB Weight IMP 5 DEC PART DEC RW DM RO REGISTERS (READ ONLY) ADDRESS TYPE DESCRIPTION FORMAT U.M. AUTH. DECIMALSNOTES 512 Bb Family DEC RO N 512 bb Device type DEC RO N 513 Bb Version DEC RO N 513 bb Revision DEC RO N 514 bb LOCK TIMER for WRONG PASSWORD DEC min RO N 515 bb Timer for Setting Enabled DEC sec RO D 516.0 bb 1=Setting enabled BOL RO N 516.1 bb 1=LOCK for w rong passw ordbol RO N 516.2 bb 1=future BOL RO N 516.3 bb 1=future BOL RO N 516.4 bb 1=future BOL RO N 516.5 bb 1=future BOL RO N 516.6 bb 1=future BOL RO N 516.7 bb 1=future BOL RO N Troubleshooting The device doesn t supply a telegram answer in 3 cases: 4. Hardware Failure (wrong connections, device off, hardware failure,...) 5. Wrong node address 6. Wrong telegram CRC. This guide is for information only. The manufacturer reserves the right to modify and / or update the product manual without reservation and without prior notice. The manufacturer, including his international representatives or agents, do not accept any liability for any incidental damage, directly or indirectly, to people or properties through the use of his products. UG_X_10600_ModbusCommunication_01_IE.docx 10/10