Ecoflam LOW NO x Ecoflam BLU
GAS BURNERS BRUCIATORI DI GAS Ecoflam was founded in 1973 in Castelfranco Veneto, near Venice in the North East of Italy. For more than thirty years Ecoflam has continued to develop all its products with constant dedication and determination addressing Technological Research, Ecology, Energy Saving, and Safety. Ecoflam today offers a full range of blown air pressure jet burners designed and tested in our GREEN modern laboratories. All products conform to CE standards and are manufactured in accordance with ISO 91 and VISION certification. Ecoflam burners guarantee high efficiency and reliable operation with significant energy savings. All models feature extreme ease of installation maintenance and flexible boiler - burner matching. Ecoflam nasce nel 1973 a Castelfranco Veneto, vicino a Venezia, nel cuore del Nord Est dell Italia. Da oltre trenta anni Ecoflam ha continuato a sviluppare tutti i prodotti con costante dedizione e determinazione rivolgendo particolare attenzione alla ricerca tecnologica, all ecologia, al risparmio energetico e alla sicurezza. Ecoflam oggi è in grado di offrire una gamma completa di bruciatori ad aria soffiata completamente progettati e sviluppati nei moderni laboratori della divisione GREEN (Gruppo Ricerca Ecoflam Energia). Tutti i prodotti sono soggetti a severi controlli e collaudi, rispettano le norme CE e sono certificati ISO 91 e VISION. I bruciatori Ecoflam garantiscono un alta efficienza e affidabilità di funzionamento unito a un notevole risparmio energetico. Tutti i modelli si caratterizzano per un estrema facilità di installazione e manutenzione e flessibilità di accoppiamento con qualsiasi tipo di generatore. OPERATION / FUNZIONAMENTO P On-Off Soft Start 1 regime di fiamma (apertura lenta)...p AB HI-LOW with servomotor regimi di fiamma con servomotore...pr Progressive Progressivo...MD Modulating Modulante
MAIN FEATURES / CARATTERISTICHE Aluminium casing up to Blu P.1 and steel casing from P 5.1 with electrical panel integrated on the burner. New high efficiency fan ventilator designed to give flame stability and easy matching. Adjustable combustion head for fine tuning / matching with different shapes of combustion chamber. Low NOx versions available from BLU 5.1 to 1.1 ( Class 3 < mg/kwh, as per EN 676). Hi - Low version with easy and fast butterfly ratio system available from Blu P 5 to Blu.1. Progressive version with electrical servomotor and adjustable mechanical cam that allows gas fine tuning. Modulating version with PID system controller with digital set point display and real time value (PID RWF or LMV 51/5 optional ). Firing head with automatic adjustable system for primary air that changes according to output required from Blu P 7.1. Easy maintenance of firing head from the burner top cover. On request tailored solutions of flame shape. BLU.1 PAB Corpo in alluminio fino al Blu.1 e in acciaio dal Blu 5.1 con pannello elettrico integrato a bordo macchina. Ventilatore al alta efficienza progettato per garantire stabilità della fiamma e facile accoppiamento. Testa di combustione regolabile per garantire migliori accoppiamenti sui differenti camere di combustione. Versione Low NOx dal Blu 5.1 al Blu 1.1 (classe 3 < mg/kwh in base alla norma EN676). Versione a due fiamme con nuovo sistema a farfalla di regolazione gas semplice e veloce, dal Blu 5.1 fino Blu.1. Bruciatori progressivi con servomotore ad alta coppia, e camma a profilo variabile per la regolazione fine del gas. Versioni modulanti con termoregolatore PID con display digitale che visualizza il valore reale e permette di regolare il set point. Sistema automatico di regolazione dell aria primaria che varia in base alla portata richiesta dal Blu 7.1. Facile manutenzione grazie alla estrazione della testa di combustione dal retro del bruciatore. A richiesta fiamma a geometria variabile. BLU 3.1 MD
WORKING FIELDS / CAMPI DI LAVORO mbar 6 5 3 1 Blu 17 P/PAB Blu 5 P/PAB Blu 35 P/PAB 5 75 1 15 15 175 5 5 75 3 kcal/h x 1 6 1 1 1 16 1 6 3 3 3 36 kw mbar 9 Blu 7 P Blu 5 P 7 6 5 3 1 Blu 5 P AB Blu 7 P AB Blu 1 P AB Blu 1 P AB Blu 1 P AB 3 5 6 7 9 1 11 kcal/h x 1 1 3 5 6 7 9 1 11 1 13 kw TECHNICAL DATA / DATI TECNICI MODELS Output Potenza termica max. Output Potenza termica min. Gas pressure Pressione Power supply Tensione Motor Motore Operation Funzionamento gas kw kcal/hx1 kw kcal/hx1 mbar V kw BLU 17 1 15, 9 76,5 3 3/,5 P-P AB BLU 5 3 197, 95 1,7 3 3/,5 P-P AB BLU 35 35 31 17 16, 3 3/,3 P-P AB BLU 5 5 3 5 15, 3 3/,55 P BLU 5 5 3 19 163, 3 3/,55 P AB BLU 7 7 6 35 31 3 3/,7 P BLU 7 7 6 5 15 3 3/,7 P AB BLU 1 1. 6 3 5 3 3/ 1,1 P AB BLU 1 1. 1.3 3 3 3/, P AB BLU 1 1.3 1.11 3 3 3/, P AB Fuel : Natural Gas (L.C.V..57 kcal/nm 3 ), LPG (L.C.V..6 kcal/nm 3 ) Combustibile : Gas Naturale (P.C.I..57 kcal/nm 3 ), GPL (P.C.I..6 kcal/nm 3 )
WORKING FIELDS / CAMPI DI LAVORO mbar 9 7 6 5 3 1 Blu 5 PR/MD Blu 7 PR/MD Blu 1 PR/MD Blu 1 PR/MD Blu 1 PR/MD 1 3 5 6 7 9 1 11 kcal/h x 1 1 3 5 6 7 9 1 11 1 13 kw mbar 1 1 6 Blu 17.1 Blu.1 6 1 1 1 16 1 kcal/h x 1 6 1 1 1 16 1 kw TECHNICAL DATA / DATI TECNICI MODELS Output Output Gas pressure Power Motor Potenza termica Potenza termica Pressione supply Motore max. min. gas Tensione kw kcal/hx1 kw kcal/hx1 mbar V kw Operation Funzionamento BLU 5 5 3 1 13, 3 3/,55 PR-MD BLU 7 7 6 19 163, 3 3/,7 PR-MD BLU 1 1. 6 17 3 3/ 1,1 PR-MD BLU 1 1. 1.3 1 15, 3 3/, PR-MD BLU 1 1.3 1.11 5 15 3 3/, PR-MD BLU 17.1 1.77 1.56 3 95 3 3/ 3 P AB-PR-MD BLU.1.15 1.53,5 1 356,9 3 3/ P AB-PR-MD Fuel : Natural Gas (L.C.V..57 kcal/nm 3 ), LPG (L.C.V..6 kcal/nm 3 ) Combustibile : Gas Naturale (P.C.I..57 kcal/nm 3 ), GPL (P.C.I..6 kcal/nm 3 )
WORKING FIELDS / CAMPI DI LAVORO mbar 1 16 1 1 1 6 Blu 3.1 Blu 5.1 Blu.1 Blu 6.1 5 1 15 5 3 35 5 5 5 1 15 5 3 35 5 5 55 kw kcal/h x 1 mbar 3 36 3 3 3 6 1 16 1 1 1 6 Blu 7.1 Blu 1.1 Blu.1 Blu 1.1 Blu 15.1 1 3 kcal/h 5 6 7 9 1 11 1 13 1 15 x 1 1 3 5 6 7 9 1 11 1 13 1 15 16 17 kw TECHNICAL DATA / DATI TECNICI MODELS Output Potenza termica max. Output Potenza termica Gas pressure Pressione Power supply Motor Motore Operation Funzionamento min. gas Tensione kw kcal/hx1 kw kcal/hx1 mbar V kw BLU 3.1 3..56 63 53,1 3 3/ 5,5 PR-MD BLU.1 3.9 3.36 75 75,3 3 3/ 7,5 PR-MD BLU 5.1 5..31 1. 1.3,5 3 3/ 11 PR-MD BLU 6.1 5. 5. 1.5 1.9 5 5 3/ 15 PR-MD BLU 7.1 7.5 6.5 1.5 1.9 5 5 3/ 15 PR-MD BLU.1.5 7.37,5. 1.7 1 5 3/ 1,5 PR-MD BLU 1.1 1.5 9.5.5.155 1 5 3/ PR-MD BLU 1.1 13.1 11.93,1.7.37,6 15 5 3/ 37 PR-MD BLU 15.1 16. 1. 3.6.96 5 3/ 5 PR-MD Fuel : Natural Gas (L.C.V..57 kcal/nm 3 ), LPG (L.C.V..6 kcal/nm 3 ) Combustibile : Gas Naturale (P.C.I..57 kcal/nm 3 ), GPL (P.C.I..6 kcal/nm 3 )
DETAILS / PARTICOLARI RWF Regulator Regolatore RWF Progressive version with servomotor and adjustable mechanical cam Servomotore con camma meccanica per versione progressiva Butterfly valve Valvola a farfalla Blu 5 1 PAB LMV51/5 System Sistema LMV51/5 Blu.1 MD Modulating version with PID regulated (proportional, integral and derivative) digital control board. Versione Modulante regolatore digitale PID. Integrated electric panel Pannello elettrico integrato Blu 5 1 PAB Diffuser Diffusore Blu 5 P AB Diffuser Diffusore Blu.1 PR/MD
LOW NOx Ecoflam LOW NO x Ecoflam The new range of Ecoflam Low NOx gas burners is the direct response to the need to reduce atmospheric pollutants in particular acid rain. The new Ecoflam engineered and designed combustion heads enable the burners to surpass the most stringent regulations and standards regarding pollutant emissions, see emission classification table. The new range of Low NOx gas burners are built to the highest quality and engineering standards as expected from Ecoflam thus ensuring high efficiency and reliable operation. I nuovi bruciatori Ecoflam Low NOx a basse emissioni di ossidi azoto rappresentano la soluzione diretta all inquinamento atmosferico ed in particolare alle piogge acide. Combustion head Testa di combustione Blu 5 P AB NOISE LEVEL / LIVELLO DI RUMOROSITA db (A) Le nuove teste di combustione progettate nei laboratori Ecoflam permettono di rispettare a pieno le normative più restrittive sulle emissioni inquinanti (vedi tabella classe emissioni). Tutti i bruciatori Low NOx garantiscono elevati standard qualitativi e assicurano alta efficienza e affidabilità di funzionamento. 7 6 71 6 73 69 75 71 7 7 7 6 5 5 3 3 1 Blu 5.1 P AB Blu 7.1 P AB Blu 1.1 P AB Blu 1.1 P AB 1 1 stage 1 stadio stage stadio Data registered from the test done with the distance of 1 metre from the burner. Misure effettuate in laboratorio ad 1 metro di distanza dal bruciatore.
Class -EN 676 LRV 9 Svizzera Class 3-EN 676 1 mg/kwh mg/kwh RAL UZ - 1 Germania Belgio 7 mg/kwh Classi normativa EN 676 NOx classe mg/kwh 1 17 1 3 NOx (mg/kwh) 1 1 7 6 EMISSION LEVEL / LIVELLO DI EMISSIONI 1 CO (mg/kwh) 1 6 LRV 9 Svizzera LRV 9 Svizzera RAL UZ - 1 Germania EN 676 Belgio NOx (Standard) Blu 5 Blu 5.1 LOW NOx Blu 7 Blu 7.1 LOW NOx Blu 1 Blu 1.1 LOW NOx Blu 1 Blu 1.1 LOW NOx Data from the test done on the boiler as per EN676 at maximum output. Dati relativi a misure effettuate su caldaia secondo EN676 al carico massimo. NOx (Low NOx) CO (Standard) CO (Low NOx) WORKING FIELDS / CAMPI DI LAVORO mbar 9 7 6 5 3 1 Blu 5.1 Low NOx Blu 7.1 Low NOx Blu 1.1 Low NOx Blu 1.1 Low NOx 1 15 5 3 35 5 5 55 6 65 7 75 5 9 95 1 15 11 115 1 15 13 kw 1 3 5 6 7 9 1 11 kcal/h x 1 TECHNICAL DATA / DATI TECNICI MODELS Output Output Gas pressure Power Motor Potenza termica Potenza termica Pressione supply Motore max. min. gas Tensione kw kcal/hx1 kw kcal/hx1 mbar V kw Operation Funzionamento BLU 5.1 Low NoX 5 3 3 197, 3 3/,55 P AB-PR-MD BLU 7.1 Low NoX 7 6 7 3, 3 3/,7 P AB-PR-MD BLU 1.1 Low NoX 75 75,5, 3 3/ 1,1 P AB-PR-MD BLU 1.1 Low NoX 1.1 96 9 9, 3 3/, P AB-PR-MD Fuel : Natural Gas (L.C.V..57 kcal/nm 3 ), LPG (L.C.V..6 kcal/nm 3 ) Combustibile : Gas Naturale (P.C.I..57 kcal/nm 3 ), GPL (P.C.I..6 kcal/nm 3 )
GAS TRAIN / RAMPE GAS Dungs SV-SVDLE To be supplied by the installer Accessori accessori a a cura cura dell'installatore dell installatore 1 3 5 6 7 1 - Main gas pipe / Tubo gas - Ball valve / Valvola a sfera 3 - Antivibration coupling / Giunto antivibrante - Gas governor / Stabilizzatore gas 5 - Gas pressure switch / Pressostato gas 6 - Safety gas valve / Valvola di sicurezza 7 - Working gas valve / Valvola di lavoro - Leakage control / Controllo di tenuta 1 - Main gas pipe / Tubo gas - Ball valve / Valvola a sfera 3 - Antivibration coupling / Giunto antivibrante - Gas filter / Filtro gas 5 - Gas pressure switch / Pressostato gas 6 - Actuator / Attuatore 7 - Actuator / Attuatore - Gas valve / Valvola gas - Leakage control / Controllo di tenuta Landis VGD... 1 3 5 9 6 7 Dungs MB-MBDLE 1 3 5 6 7 1 - Main gas pipe / Tubo gas - Ball valve / Valvola a sfera 3 - Antivibration coupling / Giunto antivibrante 5 - Gas pressure switch / Pressostato gas 6 - Gas valve / Valvola gas 7 - Leakage control / Controllo di tenuta HOW TO CALCULATE THE OVERALL DIMENSION OF BURNER COMPLETE WITH THE MATCHING GAS TRAIN In order to calculate the overall dimension of the burner complete with gas train, you need to consider value N and V indicated in the burner leaflet and the dimension, of the matching gas train choosen, according to the inlet gas pressure available in the gas train leaflet. COME CALCOLARE LE DIMENSIONI TOTALI DEL BRUCIATORE E DELLA RAMPA GAS CORRISPONDENTE Per calcolare l ingombro totale del bruciatore completo di rampa gas si deve far riferimento alla misure N and V che sono indicate nel libretto del bruciatore e alle dimensioni della corrispondente rampa gas scelta in base alla tavola di accoppiamenti disponibile nel libretto rampe. Blu 5-1 Blu 17.1-1.1 Et = A + B + P + N Et = A + B + P + V + N Ct = U + R Ct = O+ R
G I O OVERALL DIMENSIONS / DIMENSIONI E D-D1 A B C Blu 17 Blu 5 F I M A E D - D1 B O C I L H G F N E D - D1 B A C Blu 35 Blu15.1 F 1 3 N G M H O MODELS A B C D D1 E F G H I L M N O BLU 17 55 35 1 36 1 75-15 - M - - BLU 5 55 35 1 36 1 75-15 - M - - BLU 35 5 16 36 3 35 13 75-19 19 M - - Dimensions refer to the burner with gas train / Le dimensioni si riferiscono ai bruciatori con rampa gas. MODELS A B C D D1 E F G H I L M N O BLU 5 65 33 3 175 335 555 16 35 165*5 19 19 M1 115 165 BLU 5.1 LOW NOx 65 33 3 175 335 555 16 35 165*5 19 19 M1 115 165 BLU 7 65 33 3 175 395 555 1 35 5 19 19 M1 115 165 BLU 7.1 LOW NOx 65 33 3 175 395 555 17 35 5 19 19 M1 115 165 BLU 1 65 33 3 175 395 555 19 35 5 19 19 M1 115 165 BLU 1.1 LOW NOx 65 33 3 175 395 555 19 35 5 19 19 M1 115 165 BLU 1 67 35 3 31 6 555 15 35 5 19 19 M1 115 165 BLU 1 67 35 3 31 6 555 15 35 5 19 19 M1 115 165 BLU 1.1 LOW NOx 67 35 3 31 6 555 35 5 19 19 M1 115 165 BLU 17.1 71 35 35 3 5 6 5 39 3 M1 15 5 BLU.1 73 5 35 35 55 6 7 39 3 M1 15 5 BLU 3.1 91 93 33 53 7 9 66 315 315 M16 195 5 BLU.1 91 93 365 565 7 3 66 315 315 M16 195 5 BLU 5.1 119 95 5 375 575 97 3 565 33 33 M16 195 5 BLU 6.1 169 55 5 375 575 97 3 565 33 33 M16 195 5 BLU 7.1 11 55 65 7-11 6 6 M 195 3 BLU.1 1 655 65 7-11 6 6 M 195 3 BLU 1.1 131 65 65 7-11 6 6 M 195 3 BLU 1.1 1 795 65 7-11 5 6 6 M 195 3 BLU 15.1 167 7 57-175 5 11 53 6 6 M 195 55 Dimensions refer to the burner without gas train / Le dimensioni si riferiscono ai bruciatori senza rampa gas. D = short head / testa corta D1= long head / testa lunga * = for Ecomax / per Ecomax = silencer optional /silenziatore opzionale Dimension (mm) / Dimensioni (mm)
ECOFLAM S.P.A. - via Roma, 6-313 Resana (TV) - Italy tel. 3.716-71535 r.a. - fax 3.715-71553 http://www.ecoflam.it - e-mail: export@ecoflam.it FB-Blu GB-IT 1--5 Ecoflam S.p.A. RESERVES THE RIGHT TO MAKE ANY ADJUSTMENTS, WITHOUT PRIOR NOTICE, WHICH IT CONSIDER NECESSARY OR USEFUL TO ITS PRODUCTS, WITHOUT AFFECTING THEIR MAIN FEATURES. Ecoflam S.p.A. SI RISERVA IL DIRITTO DI APPORTARE AI PRODOTTI, SENZA ALCUN PREAVVISO, TUTTE QUELLE MODIFICHE CHE RITERRA UTILI E/O NECESSARIE, AL FINE DI MIGLIORARNE LA QUALITA, SENZA PREGIUDICARNE LE CARATTERISTICHE PRINCIPALI.