Ozone Systems MCP-XT Range



Похожие документы
Ozone Systems MCP-XTL Range

Generatori di ozono serie TPF-XTL Ozone Systems TPF-XTL Range

Montesilvano (Pescara) 19 Aprile Impianti ad ozono!! ING. FEDERICO DALLERA

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

HOLCROFT POWER GENERATOR FOR QUENCHING FURNACE

OSI I INDUSTR T IAL A E

OPZIONI. OPTIONALs. silenziosità unità carenate versatilità di utilizzo. low noise condensing careened units versatility of use and applications

Dimensions / Power / Potenza. Tritronic ronic 300: 6,0. Tritronic ronic 300: 1300x1150x1700 (H) mm. Weight / Peso. Tritronic ronic 300: 450 Kg

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

TIG INVERTER HF DC - AC/DC

Generatori ad inverter ed elettronici per saldatura MMA e TIG lift

RXM 2 ELETTROPOMPE MULTISTADIO ORIZZONTALI

Banchi aspiranti. Art BANCO ASPIRANTE AD 1 POSTO POLISHING BENCH SINGLE-SEATER

Serie Windy3. con sistema di drenaggio interno BPS. Caratteristiche tecniche

KT 4 X 57 W LED. ITALTOWER brand of Elentek srl

Addolcitori Softeners

DESCRIPTION DESCRIZIONE CARATTERISTICHE FEATURES

INVERTER MMA POWER ROD 131

CURVATURA - BENDING C50 ES

PUMP CONTROLLER PUMP ACTIVE CONTROLLER

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

Addolcitori Softeners

PLASMA WELDING ROBOT SISTEMA ROBOTIZZATO PER SALDATURA AL PLASMA. PLASMA WELDING ROBOTIZED SYSTEM. AUTOMATION

Materiali impiegati. 1 OPERATORE: Ottone, Acciaio INOX 2 CORPO OPERATORE: POM. 3 CORPO VALVOLA: Alluminio. 6 MOLLA: Acciaio INOX

SOLUZIONI DI CLIMATIZZAZIONE nuova linea di condizionatori. CLIMATE CONTROL SOLUTIONS a new line of cooling units

TORCIA CHIUSA PER BIOGAS tipo TBE. ENCLOSED BIOGAS FLARE TBE Type DESCRIZIONE DESCRIPTION VANTAGGI

CONTROL FAN SYSTEM VENTILATORI BLOWERS. Sistemi di controllo Control Systems SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM

FX 300 MISURATORI DI PORTATA VORTEX FLOWMETERS. FX vortex flowmeters. Benefits. Function. Design. Application. Operating Principle.

Datatech + Informazioni generali. General. Quick facts. Punti di forza

GAB. Scheda Tecnica Data Sheet. Caldaie Termostufe Termocamini Stufe Design, Quality & Production Made in Italy

BUBBLER Idrofiltri a labirinto Labyrinth hydro filters

VALVOLE A FARFALLA SERIE HT BUTTERFLY VALVES HT SERIES

T PLATE B. Scambiatori di calore a piastre saldobrasati. SCHEDA TECNICA/TECHNICAL SHEET Scambiatori di calore a piastre T-PLATE B T-PLATE B

Elettrovalvole Solenoid valves

HW 22 GRUPPI DI PRESSURIZZAZIONE A FUNZIONAMENTO AUTOMATICO CAM CAM 80-22

GEMINI. il nuovo operatore compatto e leggero. the new compact and light door operator

Addolcitori Softeners

Generatori di Vapore Steam Jet Generator

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

Diaphragm pressure reducing valves PN 40. Riduttori di pressione a membrana PN 40

MB-PULSE 4 Product Manual MB-PULSE 4 Manuale Prodotto

Avvisatori allarme Alarm panels

Soluzioni per l energia solare Solutions for solar energy

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

PRODUCT DATA SHEET. Copernico 500 sospensione - Red TECHNICAL DATA SHEET. Features. Dimensions OPTICS DIMENSIONS LAMP LAMPS INCLUDED ELECTRICAL

TERMOREGOLATORI PER STAMPI TEMPERATURE CONTROLLERS FOR MOLDS REGULATEURS DE TEMPERATURE POUR MOULES

SIMONAZZI F.LLI S.r.l. - S. ILARIO D ENZA (RE) ITALY - Tel Fax

Design, Quality & Production Made in Italy GENERATORI D ARIA. Scheda Tecnica Data Sheet. Caldaie Termostufe Termocamini Stufe

AIR CONDITIONING & HEATING FOR HEAVY-DUTY EQUIPMENT

INVERTER - MMA POWER ROD SOUND MMA

MIG PULSE - ROBOT VERSION

INVERTER MIG-MAG SYNERGIC - PULSE

SPINTA TRAZIONE THRUST TENSILE CORSA STROKE

QUADRI J QUADRI ELETTRICI DI MEDIA E BASSA TENSIONE QUADRI J MEDIUM AND LOW VOLTAGE SWITCHBOARDS. 50a. jolly set

ELETTROPOMPE CENTRIFUGHE MONOBLOCCO

Batterie circolari ad acqua calda

6 44 kw. Epsilon Echos APPLIED. < Applied

Tutti i modelli / All models : ST3 1-1 / ST3 2-3 / ST5-18 / ST10-32 / ST kg. Alimentazione Elettrica Power supply

STAND ALONE LED PV KIT WITH ROAD ARMOR

SCHEDA TECNICA LAVATRICI RC/LS IM8 TECHNICAL DATA SHEET IM8 RC/LS WASHING MACHINES

Gruppi autoclave a controllo elettronico. Electronic controlled water pressure system APPLICATIONS: GRUPPO ACB 332 GRUPPO ACM 402 APPLICAZIONI:

Транскрипт:

Ozone Systems MCP-XT Range Ozone production from air, PSA, LOX between 40 g/h and 1,300 g/h Low power consumption especially with air Compact and completely housed Complete process instrumentation Air feed gas drying incorporated Low maintenance cost

Serie MCP-XT The MCP-XT range is the OZONO ELETTRONICA INTERNAZIONALE S.R.L. midsize range of ozone generators. Five different types of systems are able to produce between 40 g/h and 1,300 g/h of ozone with very low power consumption and with ozone concentrations between 2 % wt and 14 % wt. The power consumption for ozone production from PSA and LOX is very competitive. Regarding ozone production from air OZONO ELETTRONICA INTERNAZIONALE S.R.L. is the leading manufacturer of ozone systems with respect to power consumption. All systems have a compact design and are integrated into a painted stainless steel cabinet even including the air feed gas drying system for ozone production from air. The complete system complies with IP54 requirements. To ensure a safe and reliable ozone production all systems are equipped with complete process instrumentation. The systems are delivered with a text display as human-machine-interface. A Profibus-DP extension is available as an option. The ozone generators are available stand-alone or as complete systems including ozone introduction system, ozone monitors and ozone destruction systems etc. Since four decades the ozone systems successfully and reliably operate in different applications like: - Drinking water disinfection - Removal of iron or manganese - Process water conditioning - Cooling water treatment - Odour control - Swimming pools and spas - Aquaculture like fish farming and zoos - Removal of colours and surfactants from textile industry - Removal of pollutants from petrochemical industry State-of-the-art technology combined with high quality materials and components form reliable ozone systems that operate even under different environmental conditions. The MCP-XT ozone systems meet high demands and are a future-proof investment for their owners and operators.

Technical Data Sheet MCP-XT 1 2 4 7 13 Ozone Performance [g/h] 1 Air: 3% wt (40 g/nm³) 40 80 160 280 560 PSA/LOX: 10% wt (148 g/nm³) 67 134 268 469 938 Feed Gas Supply [Nm³/h] Air with 3% wt 2 1.18 2.36 4.72 8.26 16.52 LOX with 10% wt 0.45 0.9 1.81 3.17 6.33 Cooling Water Demand [m³/h] 0.09 0.19 0.38 0.43 1.31 Power Consumption @ PCC 3 [kw] 0.6 1.3 2.5 4.4 8.8 Dimensions [mm] Depth x Width x Height 600x800x1,960 600x800x1,96 0 800 x 800 800 x 800 800 x 1,800 1,960 1,960 1,960 Weight [kg] 150 160 350 470 600 1: Cooling water temperature of 15 C, lower ozone concentration generate higher ozone output; 2: Including 18% for dryer operation; 3: Point of common connection Features Monitoring Options Technical Data Sheet Water cooled plasma cells Enclosed cabinet complying with IP54 Automatic isolation valves Air feed gas drying incorporated Air ventilation for electrical equipment Siemens-PLC S7-300 for operation Touch panel as human machine interface Inlet gas pressure Cooling water flow Ozone temperature Ozone flow Air dryer pressure Dried air pressure Air conditioning system Ozone & dissolved ozone monitor PSA system & Compressor Air ventilation for electrical equipment Diffusers / pump injector system Ozone destruction system Cooling water system

SITE CONDITIONS Design altitude < 1000 m Ambient temperature 5 35 C Humidity < 80 % Dust < 5 mg/nm 3 Pressure Gas and noxious vapours Sismicità 1 bar NO Absent ELECTRICAL DATA Mains voltage 400 Vac ± 10 % Frequency 50 60 Hz Power factory 0.86 0.98 (cos φ) Regulation range 10 100 % Protection class IP 54 Standards Compliance EN / IEC / ISO CE CONTROL & SIGNAL Ozone generator Start / Stop Local / remote Ozone production regulation Local / remote ( 4-20 ma ) MATERIALS In contact with ozone In contact with water Enclosure AISI 316 L, Viton, PTFE 304 L, 316 L Acc. al C. vern./mild steel SIGNAL TO MASTER CONTROLLER Inverter modulation Alarms&Block sum Potential free contacts Potential free contacts

MCP 1/A Flow sheet

MCP 1/O Flow sheet

MCP 1/A Layout

MCP 1/O Layout

MCP 2/A Flow sheet

MCP 2/O Flow sheet

MCP 2/A Layout

MCP 2/O Layout

MCP 4/A Flow sheet

MCP 4/O Flow sheet

MCP 4/A Layout

MCP 4/O Layout

MCP 7/A Flow sheet

MCP 7/O Flow sheet

MCP 7/A Layout

MCP 7/O Layout

MCP 13/A Flow sheet

MCP 13/O Flow sheet

MCP 13/A Layout

MCP 13/O Layout