Residual current device 96x96mm

Documenti analoghi
Residual current device 96x96mm

Delta 72 - S. Residual current device 72 x7 2mm. Relè differenziale PROTEZIONE PROTECTION

Residual current device 72 x7 2mm

Residual current device 4 Module

Residual current device 2 Module

Residual current device 96x96mm

Residual current device 2 Module

Delta D4 - F. Relè differenziale 4 Moduli. Residual current device 4 Module PROTEZIONE PROTECTION

Residual current device 4 Module

Delta 72 - h. Relè differenziale. Residual current device 72 x 7 2mm PROTEZIONE PROTECTION

Delta D4 - I. Residual current device 4 Module. Relè differenziale 4 Moduli PROTEZIONE PROTECTION

Residual current device 4 Module

Direct and pulsanting voltage or current digital meter 96x48 mm

Residual current device 4 Module

AQMrad Analog Meters for alternating current 48x48mm

Low voltage Network monitor 96x96mm

RI-R60 DIPOSITIVO PER IL CONTROLLO PERMANENTE DELL ISOLAMENTO PER RETI ISOLATE IT

Nemo 72-L Network Monitor

Network monitor for low voltage 4 module

MANUALE D USO INDICATORI DIGITALI / DIGITAL DISPLAY UNIT USER S MANUAL

COMMUTAZIONE AUTOMATICA E la funzione che governa la commutazione tra due linee in un tempo regolabile fra 0,5 e 120 secondi.

Conto imp. Pulse Acquisition. Concentratore Remoto 4 moduli CONTEGGIO ENERGIA ENERGY COUNTING. 4 module RS485. gas kcal RS485. gas kcal RS485.

Relè differenziali 4. 01

Digital meter of: Voltage dc or ac Current dc or ac Frequency 72x72 mm

Conto D k W h. Static Meter submetering applications Active Energy 1 module

Conto imp. Concentratore Remoto 4 moduli. Pulse Acquisition 4 module CONTEGGIO ENERGIA ENERGY COUNTING RS48. gas kcal. gas kcal. gas kcal 4...

STRUMENTI ANALOGICI ELETTRONICI ELECTRONIC ANALOGIC INSTRUMENTS

Insulation monitor for hospital use 4 module

Network monitor for low voltage

Static Meter submetering applications 4 module

Relè differenziali. I dettagli che fanno la differenza Un unica e completa gamma per la protezione differenziale

Power relay, single-phase network 2 Module

RELÈ DIFFERENZIALI DELTA

IMM Drukmat voor het beveiligen van gevaarlijke zones rondom machines. Indien men op de mat staat schakelt de mat de noodstop in.

ESECUZIONE DA INCASSO Tipo R2D 2 soglie di intervento. TA esterno. Sicurezza positiva. Tipo R3D 2 soglie di intervento. TA esterno.

Network monitor for direct current 4 module

Static Meter submetering applications 4 module

WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]

SOLID STATE RELAY MODULES - 1 STAGE 3A WITH FUSE PROTECTION SOLID STATE RELAY MODULES - 4 STAGE 3A WITH FUSE PROTECTION

ELETTRONICA DUE AMPLIFICATORE PER FIBRE / FIBER SENSOR

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003

20mA. 4mA. 20mA. 4mA. RQM - Analog Meters for direct current 48x48mm 72x72mm 96x96mm

SENSORI INDUTTIVI M30 x 1,5 INDUCTIVE SENSORS M30 x 1,5

Informazione Tecnica. 6. Relè differenziali di terra

Siemens S.p.A Apparecchi di controllo SENTRON. Aggiornamento Catalogo SENTRON 02/2012

Trasformatori e Alimentatori Transformers and power supplies. ASSA ABLOY, the global leader in door opening solutions

Static Meter submetering applications for low votage network 4 module

SPECIFICA TECNICA LEONARDO VA

Relè di protezione elettrica Trifase, Trifase con neutro, Monofase, Multifunz. Modello DPC02 B003

RELÈ DIFFERENZIALI serie RDC

G4BM480V12ATL20. Dati tecnici. Controllo potenza reale sistemi monofase o trifase

Commutatori motorizzati 3KA71

Network monitor for direct current 4 module

COMPONENTI PER L ELETTRONICA INDUSTRIALE E IL CONTROLLO DI PROCESSO. Soglie di allarme per montaggio su guida DIN SERIE DAT5028-DAT5024

G4BM400V12ATL20. Dati tecnici. Controllo potenza reale sistemi monofase o trifase

Custodia per montaggio a pannello, grado di protezione (frontale) IP65 di serie e a richiesta la porta RS485 di comunicazione seriale.

motori asincroni per applicazione con inverter serie ASM asynchronous motors for inverter application ASM series

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

IPS VA DC/AC INVERTER. Specifiche tecniche Data sheet Vdc 230V 50 Hz

Codice Potenza Prezzo V 15 A 224, V 25 A 295, V 40 A 485, V 20 A 540,00

Concentratore Impulsi, 12 ingressi, 4 mod. DIN, uscita RS485

Relè di protezione elettrica Trifase, trifase con neutro, Multifunzione Modelli DPB01, PPB01

Conto D k W h. Contatore Statico con certificazione MID applicazione di conteggio secondario Energia Attiva 1 modulo

Alimentatori. Power supply

SIMONAZZI F.LLI S.r.l. - S. ILARIO D ENZA (RE) ITALY - Tel Fax

RD3 e RCQ020 Relè differenziali elettronici di bassa tensione per interruttori modulari e scatolati

Product QUADRI ELETTRONICI ELECTRONIC CONTROL PANEL - ECL 1 / ECL 2-

TRASFORMATORI DI CORRENTE PER BASSA TENSIONE

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

Network monitor for low voltage 4 module DIN 43880

Relè di protezione elettrica Monofase per massima o minima corrente CA/CC Modelli DIB01, PIB01

FB2. Alternatori brushless da 12,5 a 19 KVA Brushless alternators from 12,5 up to 19 KVA

Attuatore elettrico Electrical actuator

ELR RELÈ DIFFERENZIALI DI TERRA CEI EN Annex M CT TRASFORMATORI DI CORRENTE TOROIDALI RSR RELÈ RIAVVIAMENTO AUTOMATICO MOTORI

Soft Starters TMC7 TMS9

SERIE 88 Temporizzatore ad innesto 8 A. Multifunzione Undecal Innesto su zoccolo serie 90. senza START esterno

IT Relè differenziale di protezione a toroide separato Foglio istruzioni

RELE DIFFERENZIALI DI TERRA RELE DI CONTROLLO DELL ISOLAMENTO

MONITOR DI ISOLAMENTO

Network monitor for low voltage 96x96mm

Alimentatori LED LED drivers

DUS [80] thytronic. Relè di minima tensione continua a due soglie Two-setting DC undervoltage relay APPLICAZIONE APPLICATION

TFT LCD -5 /COL Monitor a colori LCD TFT 5 senza fili 2.4 GHz 2.4 GHz Wireless CCD 5" TFT color LCD monitor

Relè di Protezione MC3V-CEI A70. MC Serie

QUADRI J QUADRI ELETTRICI DI MEDIA E BASSA TENSIONE QUADRI J MEDIUM AND LOW VOLTAGE SWITCHBOARDS. 50a. jolly set

Static Meter with sealable front frame and terminals for fiscal use (UTF) Run hour meter with threshold

Controllo tensione Monofase ( V):

Controllo tensione Monofase ( V):

Relè di protezione serie PM

MPDS-1CV/1CC HV PUSH

INSULATION CONTROL RELAYS RELE DI CONTROLLO DELL ISOLAMENTO RIDUTTORI DI CORRENTE TOROIDALI TOROIDAL CURRENT TRANSFORMERS

RELÈ DI ISOLAMENTO E MISURA ISO

DUK. DUK (80) Relè di minima tensione continua DC undervoltage relay FOGLIO TECNICO / DATA SHEET APPLICAZIONE

sensori per cilindri magnetic sensors for cylinders

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

SERIE 19 Interfacce modulari di segnalazione e bypass

SERIE 85 Relè temporizzato ad innesto 7-10 A. 2 contatti, 10 A Alimentazione AC/DC non polarizzata Innesto su zoccoli serie 94

Perfection in force measurement FORZA NOMINALE / NOMINAL FORCE. 1 0kN - 20kN - 30kN

Servomotori Brushless serie BT1 tensione 230 Vac coppie nominali da 0,5 a 1,9 Nm

Expansion card. EXP-D8-120 I/O Interface Card 8 AC Opto-coupled Digital Inputs 8 DC Digital Outputs

Transcript:

PROTEZIONE PROTECTION Relè differenziale 96x96mm Applicazioni industriali onerose, con presenza di correnti distorte: inverter, variatori di velocità, carichi non lineari Filtro per componenti armoniche Non utilizzabile per la protezione delle persone Punto di intervento selezionabile 50mA 30A (18 portate) Visualizzazione istantanea percentuale di IΔ n Sicurezza positiva o negativa selezionabile in campo Test automatico permanente Relè di allarme + preallarme oppure relè allarme con doppio scambio Residual current device 96x96mm Heavy industrial applications with distorted current waveforms: inverters, variable speed drives, rectifiers, frequency regulators Filter for harmonics It cannot be used to protect people Selectable set point 50mA 30A (18 ranges) Instantaneous display as percentage of IΔ n Field-selectable negative or positive security (fail safe) Automatic permanent test Alarm relay + pre-alarm or alarm relay with double exchange Delta 96-F Segnalazione intervenuto allarme (LED rosso) Red LED for an occured alarm Indicazione istantanea della corrente differenziale Instantaneous display of earth leakage current Selettore portata x1 / x10 / x100 Range selector x1 / x10 / x100 Selezione punto di intervento IΔn Setting intervention threshold IΔn ~ Pulsante di ripristino Reset key Pulsante Test Test key Selettore stato relè uscita: ND (norm. diseccitato) sicurezza negativa Ne (norm. eccitato) sicurezza positiva Switch for state output relay: ND (norm. de-energised) negative security Ne (norm. energised) positive security Selezione tempo di intervento Setting intervention time Segnalazione apparecchio alimentato (LED verde) Green LED for fed meter Selettore: Selector: Al.2 allarme con 2 contatti SPDT Al.50% allarme + preallarme 50% IΔn Al.2 alarm with 2 SPDT contacts Al.50% alarm + 50% IΔn pre-alarm NT746 06-2010 2 a Ed. pag.1/5

PORTATE RANGES BLOCCO ELETTRICO ISTANTANEOUS FORMA D ONDA WAVEFORM FILTRO COMPONENTI ARMONICHE FILTER FOR HARMONICS NORMA DI RIFERIMENTO ACCORDING TO ALLARME ALARM VISUALIZZAZIONE IΔn DISPLAY USCITA RELE RELAY OUTPUT SICUREZZA positiva / negativa SECURITY positive / negative TEST RIPRISTINO RESET ALIMENTAZIONE AUSILIARIA AUXILIARY SUPPLY DIMENSIONI DIMENSIONS MODELLO MODEL 96-F CODICE CODE RD2G21... NOTA TECNICA TECHNICAL NOTE 19: 0,03...30A NT746 18: 0,5...30A t=0s a/at IΔn 30mA Sinusoidale (tipo AC) Sinusoidal (AC type) Pulsante parzializzata con componente continua (tipo A) Chopped pulsating with superimposed dc (A type) Selezionabile Selectable Fisso Fixed EN60947-2 IEC60947-2 1 Uscita Relè 1 Relay Output 2 Uscite Relè 2 Relays Output 1 Uscita + Preallarme 1 Output + Pre-alarm Barra LED LED Bargraph Display SPDT SPDT + SPST 2 SPDT Selezionabile Selectable Locale Local Remoto Remote Automatico Automatic Locale Local Remoto Remote Automatico Automatic 230Vca/ac 24-48-115-240-400Vca/ac 20...150Vcc/dc 10...36Vcc/dc 2 Moduli 2 Module 4 Moduli 4 Module 48 x 48 mm 72 x 72 mm 96 x 96 mm In alternativa On choice Non realizzabile con al.aus.20...150vcc-48vca Not available with aux. supply 20...150Vdc-48Vac NT746 06-2010 2 a Ed. pag.2/5

CODICI DI ORDINAZIONE ORDERING CODE RD2G211B RD2G212B RD2G213B RD2G214B RD2G215B RD2G21HB AL. AUSILIARIA AUX. SUPPLY 24V ca/ac 115V ca/ac 230V ca/ac 240V ca/ac 4400V ca/acr 20...150Vcc/dc + 48V ca/ac INGRESSO Inserzione: linea bassa tensione, con trasformatore serie TD Forma d onda IΔn: sinusoidale (tipo AC) o pulsante parzializzata con componente continua (tipo A) in accordo con EN60947-2 (annesso B e M) ed. VIII (2007) / IEC60947-2 Frequenza nominale fn: 50Hz Frequenza di funzionamento: 47...63Hz Filtro per componenti armoniche (applicazioni industriali, non utilizzabile per la protezione delle persone). INPUT Connection: low voltage lines, with series TD transformer Waveform I n: sinusoidal (type AC) or chopped pulsating with superimposed d.c. (type A) according to EN60947-2 (annex B and M) IEC60947-2 Rated frequency fn: 50Hz Working frequency: 47...63Hz Filter for harmonic (industrial application, it cannot be used to procted people) PREDISPOSIZIONE Punto di intervento IΔn: selezionabile con potenziometro a 7 posizioni, 3 gamme x1 - x10 - x100 Portate IΔn: vedi tabella SET UP Current set point I n: selectable by 7-position potentiometer, 3 ranges x1 - x10 - x100 Ranges I n: see table 0,05 0,075 0,1 0,15 0,2 0,3 X1 50mA 75mA 100mA 150mA 200mA 300mA IΔn X10 500mA 750mA 1A 1,5A 2A 3A X100 5A 7,5A 10A 15A 20A 30A Corrente differenziale di non intervento: 0,5 IΔn Tempo di intervento t: selezionabile con potenziometro a 7 posizioni Campo regolazione t: 0-0,15-0,25-0,5-1 - 2,5-5 secondi Non-operating residual current : 0,5 I n Intervention time t: selectable by 7 position potentiometer Adjustable range t: 0-0,15-0,25-0,5-1 - 2,5-5 seconds Soglia intervento (IΔn) Set point (IΔn) Ritardo impostato t(s) Selected delay t(s) Tempo non intervento @ 2IΔn Non-operating time at @ 2IΔn Max. ritardo @ 5IΔn Max. delay @ 5IΔn 0,05...30A 0,15s 0,25s 0,5s 1s 2,5s 5s 0,15s 0,25s 0,5s 1s 2,5s 5s 0,24s 0,35s 0,63s 1,20s 2,80s 5,50s Selettore Al.2 - Al.50% Al.2: relè di allarme con doppio scambio Al.50%: relè di allarme + preallarme 50% IΔn Il relè contrassegnato 60-61 - 62 è un preallarme con soglia intervento fissa, pari a 50% del valore di IΔn selezionato Switch Al.2 - Al.50% Al.2: alarm relay with double exchange Al.50%: alarm relay + pre-alarm 50% IΔn Relay marked 60-61 - 62 is a pre-alarm state with fixed intervention threshold, equal 50% of selected IΔn value SEGNALAZIONE SIGNALING NT746 06-2010 2 a Ed. pag.3/5 Strumento alimentato: LED verde "ON" Valore istantaneo IΔn: 4 LED gialli, 20-30 - 40-50% del valore IΔn impostato Intervento allarme: LED rosso "TRIP" + commutazione relè TRIP Interruzione collegamenti relè - toroide: lampeggio LED rosso "TRIP" + commutazione relè TRIP Preallarme: commutazione relé 50% I n CONTROLLO Test manuale: verifica l'efficienza del relè differenziale Locale: pulsante frontale Remoto: chiusura contatto esterno (Non realizzabile con aux cc e con Uaux 48Vca) Test automatico permanente: verifica la continuità del collegamento relè differenziale - toroide Power ON: green LED "ON" Instantaneous value IΔn: 4 yellow LED's, 20-30 - 40-50% of set IΔn value Alarm intervention: red LED "TRIP" + TRIP relay switching Ring current transformer-relay connection failure: red LED "TRIP" blinking + TRIP relay switching Pre-alarm: 50% I n relay switching CONTROL Manual test: it verifies the residual current relay perfect working Local: front key Remote: by external contact closing (Not available with dc supply and Uaux 48Vac) Automatic continuous test: it verifies the integrity of the connection between relay and ring core

ALLARME Memorizzazione intervento: LED rosso "TRIP" + autoritenuta relè Ripristino (reset): manuale Manuale locale: pulsante frontale Manuale remoto: chiusura contatto esterno Ripristino inibito con corrente differenziale persistente: > 50% IΔn ALARM TRIP state memorization: red LED "TRIP" + relay self-retaining Reset: manual Local manual: front key Remote manual: external contact closing Inhibited reset with persistent residual current: > 50% IΔn USCITA Allarme con doppio scambio (Al.2) Relè TRIP : 2 contatti di scambio SPDT Allarme + preallarme (Al.50%) Relè TRIP : 1 contatto di scambio SPDT Relè 50% I n: 1 contatto di scambio SPDT (sicurezza negativa) Sicurezza negativa/condizionata (relè normalmente diseccitato) oppure positiva/incondizionata (relè normalmente eccitato): selezionabile tramite dip switch OUTPUT Alarm relay with double exchange (Al.2) TRIP relay: 2 SPDT contacts Alarm + pre-alarm (Al.50%) TRIP relay: 1 SPDT contact 50% I n relay: 1 SPDT contact (negative security) Negative security (normally de-energised relay) or positive security fail safe (normally energised relay): selectable by dip switch ALIMENTAZIONE AUSILIARIA Valore nominale Uaux: 48-115V - 230V - 240V - 400V Variazione ammessa: 0,85...1,1Uaux - 40...60V (Uaux 48V) Frequenza nominale: 50Hz Variazione ammessa: 47...63Hz Autoconsumo: 2,5VA Valore nominale Uaux: 20...150Vcc Protezione contro l inversione di polarità Autoconsumo: 2,5W Insensibilità ai buchi di tensione con durata fino a 150ms (Uaux nominale) AUXILIARY SUPPLY Rated value Uaux: 48-115V - 230V - 240V - 400V Tolerance: 0,85...1,1Uaux - 40...60V (Uaux 48V) Rated frequency: 50Hz Tolerance: 47 63Hz Rated burden: 2,5VA Rated value Uaux: 20...150Vdc Protected against incorrect polarity Rated burden: 2,5W Immunity to short interruption of supply voltage up to 150ms (Rated Uaux) SOLAMENTO (EN/IEC 60947-1) Categoria di installazione: III Grado di inquinamento: 2 Tensione di riferimento per l isolamento: 450V Prova di tensione a impulso 5kV 1,2/50µs 0,5J Circuiti considerati: ingresso, uscita relè, alimentazione ausiliaria Prova a tensione alternata 2,5kV valore efficace 50Hz/1min Circuiti considerati: ingresso, uscita relè, alimentazione ausiliaria Prova a tensione alternata 4kV valore efficace 50Hz/1min Circuiti considerati: tutti i circuiti e massa INSULATION (EN/IEC 60947-1) Installation category: III Pollution degree: 2 Insulation reference voltage: 450V Impulse voltage test 5kV 1,2/50μs 0,5J Considered circuits: input, relay output, auxiliary supply A.C. voltage test 2,5kV r.m.s. 50Hz/1 min Considered circuits: input, relay output, auxiliary supply A.C. voltage test 4kV r.m.s. 50Hz/1 min Considered circuits: all circuits and earth PROVE DI COMPATIBILITA ELETTROMAGNETICA Prove di emissione in accordo con EN / IEC 60947-2 Prove di immunità in accordo con EN / IEC 60947-2 TESTS FOR ELECTROMAGNETIC COMPATIBILITY Emission tests according to EN / IEC 60947-2 Immunity tests according to EN / IEC 60947-2 CONDIZIONI AMBIENTALI Temperatura di impiego: -5 50 C Temperatura limite di funzionamento: -10 55 C Temperatura di magazzinaggio: -40 70 C Umidità relativa (IEC60755): 50% (valore massimo a 40 C) Adatto all utilizzo in clima tropicale Massima potenza dissipata 1 : 2W 1 Per il dimensionamento termico dei quadri ENVIRONMENTAL CONDITIONS Nominal temperature range: -5 50 C Limit temperature range: -10 55 C Limit temperature range for storage: -40 70 C Relative humidity (IEC60755): 50% (highest value at 40 C) Suitable for tropical climates Max. power dissipation 1 : 2W 1 For switchboard thermal calculation CUSTODIA Custodia: incasso (foratura pannello 92x92mm) Frontale: 96x96mm Profondità: 80mm Connessioni: faston 6,3x0,8mm Materiale custodia: policarbonato autoestinguente Grado di protezione (EN/IEC 60529): IP40 frontale, IP20 morsetti Peso: 280 grammi HOUSING Housing: flush mounting (panel cutout 92x92mm) Front frame: 96x96mm Depth: 80mm Connections: fast-ons 6,3x0,8mm Housing material: self-extinguishing policarbonate Protection degree (EN/IEC 60529): IP40 front frame, IP20 terminals Weight: 280 grams NT746 06-2010 2 a Ed. pag.4/5

NT746 06-2010 2 a Ed. pag.5/5 La I.M.E. S.p.A. si riserva in qualsiasi momento, di modificare le caratteristiche tecniche senza darne preavviso. / I.M.E. S.p.A. reserves the right, to modify the technical characteristics without notice. SCHEMI D INSERZIONE WIRING DIAGRAMS S 291/123 S 291/86 TRIP RESET TEST TRANSFORMER AUX. TRIP Al.50% RESET TEST TRANSFORMER AUX. INPUT SUPPLY INPUT SUPPLY (+) ( ) (+) ( ) 19 18 17 60 61 62 4 6 1 3 2 20 21 19 18 17 60 61 62 4 6 1 3 2 20 21 Al.2 B A L1 L2 L3 N Al.50% DIMENSIONI DIMENSIONS 92 96 92 96 80 12 B A L1 L2 L3 N