a secco in resina potenza da 3,15 MVA fino a 10 MVA voltaggio fino a 36 kv frequenza Hz 50-60 standards IEC 60076-11 - IEEE 57.12.



Documenti analoghi
TRASFORMATORI DI POTENZA POWER TRANSFORMERS

TRASFORMATORI DI POTENZA POWER TRANSFORMERS

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no.

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

MANUALE D USO PER TRASFORMATORI DI TENSIONE PER MISURA IN MEDIA TENSIONE

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

Il nostro pool di specialisti è disponibile anche per consulenze e collaborazioni nella progettazione e realizzazione di prodotti su misura.

TRASFORMATORI DI DISTRIBUZIONE IN RESINA CAST RESIN DISTRIBUTION TRANSFORMERS

Generatore radiologico

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/ Fax 057/ internet:

IT.05XX. VARIATORI DI TENSIONE "Variac" MONOFASE E TRIFASE T T S. Temperatura: Ambiente fino a 45 C

PRODUCTION RANGE GAMMA PRODUZIONE

pressostati pressure switches

Catalogo Prodotti Ferroviari Railway Products Catalog


Quality Reliability Flexibility. Trasformatori di potenza in olio Oil Transformers

Tester prova batterie

EWC GROUP SRL TRANSFORMERS

RXM4AB1BD Relè plug-in miniatura - Zelio RXM - 4 C/O - 24 V CC - 6 A

Diffusori ad alta induzione a geometria variabile High induction diffuser variable geometry

SIRMET ELETTRICA S. r. l. SIRMET ELETRICA S. r. l.

Leddy Architectural LED WALL LIGHT / APPARECCHIO A PARETE 3 LED LED WALL LIGHT / APPARECCHIO A PARETE 9 LED

Apparecchiature di media tensione isolate in gas Gas-insulated medium voltage equipments. Serie G

RSB1A120F7 Relè plug-in interfaccia - Zelio RSB - 1 C/O V CA - 12 A

Inverter Aurora Power-One: descrizione della protezione anti-islanding

POMPA A MANO MODULARE DI EMERGENZA

M12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD MAIN OUT V JACK 50/60Hz 3 T1,25A. R mic. line AUX TUNER TAPE CD

COMPRESSORE ROTATIVO A VITE CSD HP

Risparmio energetico con motori ad alta efficienza. Università di Bologna Il Miglioramento dell efficienza energetica

Energy Transmission & Distribution Services - Italia

FORNI DA TEMPRA IN VUOTO

Libri di testo adottati: Macchine Elettriche, HOEPLI di Gaetano Conte;

Le macchine elettriche

ABL8RPS24050 Alimentatore con commutazione regolata - 1 o 2 fasi V CA - 24 V - 5 A

I collettori solari termici

CABINE ELETTRICHE DI TRASFORMAZIONE

INTECNO LINEAR. Motion SISTEMI LINEARI, MOTORIDUTTORI, AZIONAMENTI GEAR MOTORS, DRIVES. member of TRANSTECNO. group

PRODUCT DATA SHEET. Copernico 500 sospensione - Red TECHNICAL DATA SHEET. Features. Dimensions OPTICS DIMENSIONS LAMP LAMPS INCLUDED ELECTRICAL

M12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD VOLUME BASS HIGH. MAINOUT V JACK 50/60 Hz 3 T1,25A. R mic.

CLEAN ROOM CELLE CLIMATICHE

Indice Index F10 F10

Trasformatori elettrici a basse perdite

I vantaggi energetici ed ambientali della piccola e micro cogenerazione

Guida all installazione del prodotto 4600 in configurazione plip

Risparmia fino al 30% di consumi di elettricità. Facile e veloce installazione nel proprio circuito elettrico. Non necessitano di alcuna munutenzione.

GUIDA PER LE CONNESSIONI ALLA RETE ELETTRICA DI DEVAL

Informazioni Prodotto

Working data. Dimensioni cassa Dimensions case. Fissaggio Installation. 175x175x100. A parete Wall-fixing. 75x250x100

Calcolo del rifasamento

MANUALE DI ISTRUZIONE ED USO SCHEDE ELETTRONICHE DI FRENATURA PER MOTORI C.A. FRENOMAT-2, FRENOSTAT R

Product note Migrazione da Emax ad Emax 2 mantenendo la certificazione in base alle norme serie IEC per i quadri di bassa tensione

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s

SPECIFICA TECNICA APPARECCHIATURE PREFABBRICATE CON INVOLUCRO METALLICO IN MEDIA TENSIONE PER INTERNO ISOLATE IN ARIA SCOMPARTI PER CABINE SECONDARIE

COMPRESSORE ROTATIVO A VITE CSM MINI ,5-7,5 HP

Recuperatore di Calore

Il silenzio del mare. PROPULSIONE elettrica e ibrida

Impianti fotovoltaici connessi alla rete

IL RISPARMIO ENERGETICO E GLI AZIONAMENTI A VELOCITA VARIABILE L utilizzo dell inverter negli impianti frigoriferi.

Prese di Corrente Rotanti

20.18-ITA Assemblaggio valvole AGS a triplo servizio

REATTANZE INDUTTIVE DI LINEA Filtri elettrici di potenza per l automazione industriale

Il contributo di Anie per i trasformatori ad alta efficienza energetica. Ing. Tommaso Genova Associazione Energia Federazione Anie

NORME ORDINATE PER ARGOMENTO

Formazione Tecnica Schneider Corso C1 Studio e progettazione di una cabina di trasformazione MT/BT

AxSun INVERTER PER APPLICAZIONI FOTOVOLTAICHE. Manuale d Uso

I ventilatori sono stati progettati e prodotti secondo le procedure definite nella BS EN ISO 9001:2008.

LA SOLUZIONE PER I VOSTRI PROBLEMI

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION

MISURE DI GRANDEZZE ELETTRICHE

Libri di testo adottati: Elettrotecnica generale HOEPLI di Gaetano Conte;

COMUNE DI GAVARDO (BS)

Sistemi di protezione e coordinamento negli impianti elettrici di BT

HOLCROFT POWER GENERATOR FOR QUENCHING FURNACE

PROVE SULLA MACCHINA A CORRENTE CONTINUA

Sez. J.1 Sistemi e tecnologie ad aria compressa, di ausilio alla produzione SISTEMI DI RAFFREDDAMENTO TUBI VORTEX FRIGID-X TM VORTEX TUBE

Variatori di potenza per carichi elettrici, max 30 KW pausa/impulso 24 V AC

Generatore termo acustico

RIDURRE I COSTI ENERGETICI!

QUADRI J QUADRI ELETTRICI DI MEDIA E BASSA TENSIONE QUADRI J MEDIUM AND LOW VOLTAGE SWITCHBOARDS. 50a. jolly set

DESCRIPTION DESCRIZIONE CARATTERISTICHE FEATURES

MANUALE UTENTE VIVALDI MA-5240 MA-5120 MA-5060 MIXER AMPLIFICATO

Gamma BRUSHLESS CROUZET

1). Descrizione dell impianto attraverso uno schema e specifica della funzione dei componenti.

NORME TECNICHE TE 666 Edizione per la fornitura di. TRASFORMATORI DI POTENZA MT/bt con isolamento in resina epossidica

Quality Certificates

ITI M. FARADAY Programmazione modulare

ACEA Distribuzione SpA Direzione Operazioni/Rete AT FORNITURA DI TRASFORMATORI AT/MT PER LE CABINE PRIMARIE CINECITTA /O TOR DI VALLE VILLA BORGHESE

B.U. LV MOTORS Offerta Motori ABB

I vuoti di tensione: definizioni, origini e grandezze caratteristiche. G. Carpinelli

Estendere Lean e Operational Excellence a tutta la Supply Chain

Impianti di propulsione navale

Il ruolo del fornitore di macchine nella manutenzione preventiva e calibrazioni. Dott. Marco Bellentani

BESST C.O.P. ~ 4,6 SERIE PECULIARITÀ. - Funzionamento invernale garantito fino a -15 C. con gas refrigerante ecologico R410A

Rapporto ambientale Anno 2012

per la compressione di aria e gas neutri per alto vuoto VUOTO A E R Z E N E R M A S C H I N E N F A B R I K G M B H G IT

DEVIATORI DI FLUSSO DIVERTER VALVES

Convertitori elettronici di potenza per i veicoli elettrici

I.T.I.S. M. FARADAY - Programmazione modulare

MILLIOHM METER PORTATILE 1 MANUALE UTENTE PROFESSIONAL ELECTRONIC INSTRUMENTS MILLIOHM - METER

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

Transcript:

TRASFORMATORI DI POTENZA GENERALITÀ Oltre ai trasformatori di distribuzione, la ELETTROMECCANICA COLOMBO produce trasformatori di potenza, sia per usi comuni (per abbassamento-elevamento tensione su linee principali, per alimentazione di trasformatori ausiliari, per trasferire in rete la corrente autoprodotta) che per usi specifici (autotrasformatori, trasformatori di avviamento, di isolamento, etc). La loro tecnologia è collaudata da diversi decenni. In tempi recenti, grazie ai progressi compiuti dall elettronica di potenza, è invalso l uso di trasformatori per convertitori, collegati gruppi di conversione (a 6,12, 24 impulsi) per l azionamento di numerosi tipi di macchine (ventilatori,pompe,motori etc). Come stabilito dalle norme IEC 61378-1, la produzione di trasformatori adatti a funzionare con convertitori deve tener conto del tipo di lavorazione da effettuare, del tipo di convertitore e delle armoniche. La Elettromeccanica Colombo ha acquisito una notevole esperienza in questo settore sia per trasformatori in olio che a secco con una grande quantità di macchine prodotte in funzione da anni con prestazioni più che soddisfacenti. Per tutti i trasformatori di potenza la capacità tecnologica unita ad un rigoroso sistema qualità certificato ISO 9001 garantiscono un prodotto affidabile con una vita utile in normali condizioni di esercizio di oltre 30 anni. GAMMA DI PRODUZIONE L'attuale gamma comprende i seguenti trasformatori: immersi in olio potenza da 3,15 MVA fino a 40 MVA voltaggio da 3 kv fino a 72,5 kv frequenza Hz 50-60 standards IEC 60076-13 - IEEE 57.12.00 a secco in resina potenza da 3,15 MVA fino a 10 MVA voltaggio fino a 36 kv frequenza Hz 50-60 standards IEC 60076-11 - IEEE 57.12.01 PROVE Tutti i trasformatori vengono collaudati singolarmente. In particolare eseguiamo: PROVE DI ROUTINE-ACCETTAZIONE Misura del rapporto di trasformazione e controllo della polarità e dei collegamenti Prova di isolamento con tensione indotta Prova di isolamento con tensione applicata Misura della resistenza degli avvolgimenti Misura delle perdite e della corrente a vuoto Misure della tensione di corto circuito e delle perdite di carico Misura delle scariche parziali (solo trasf. in resina) PROVE DI TIPO Prova ad impulso atmosferico Prova di riscaldamento Misura del livello di rumore PROVE SPECIALI Prova di tenuta al corto circuito. Tutte le prove di routine sono incluse nel prezzo di fornitura ed eseguite presso la nostra sala prove. Le prove di tipo sono eseguite presso la nostra sala prove ed addebitate. Dette prove possono essere presenziate dal cliente o da suoi rappresentanti. Le prove speciali vengono eseguite presso il laboratorio CESI di Milano ed addebitate al costo. POWER TRANSFORMERS GENERAL In addition to distribution transformers, ELETTROMECCANICA COLOMBO manufactures power transformers, either for general purpose (reducing voltage from main grid, feeding auxiliary transformers, transferring into the grid the own produced current) and for specific purpose (autotransformers, starting transformers, insulating transformers, etc). Their technology is proved since many decades. In the recent times, the progress achieved by power electronics has lead to the common use of converter transformers connected to rectifier groups (6-12-24 pulse) for the drive of various type of machines (pumps, ventilators, motors ). As stated from IEC 61378-1 standards, the production of transformers fit to work with converters must take into account the type of work, type of converter, and type of harmonics. Elettromeccanica Colombo has acquired an important experience in this sector, either for oil and dry transformers with a great quantity of transformers on duty since many years with satisfactory result. For all power transformers the technological ability connected with a quality assurance system certified ISO 9001 guarantee a reliable product with an expected life time in normal conditions over 30 years. PRODUCTION RANGE The actual production range includes the following ratings: oil filled power from 3,15 MVA up to 40 MVA voltage from 3 kv up to 72,5 kv frequency Hz 50-60 standards IEC 60076-13 - IEEE 57.12.00 dry type cast resin power from 3,15 MVA up to 10 MVA voltage up to 36 kv frequency Hz 50-60 standards IEC 60076-11 - IEEE 57.12.01 TESTS All trasformers are individually tested. We carry out the following: ROUTINE-ACCEPTANCE TEST Measurement of voltage ratio and testing of voltage vector relationship Induced over-voltage withstand test Separate source voltage withstand test Measurement of winding resistance Measurement of no load loss and current Measurement of impedance voltage and load loss Partial discharges measurement (only for resin trasformers) TYPE TESTS Temperature rise test Lightning impulse test Measurement of sound level SPECIAL TEST Short circuit withstand All routine tests are made in our test room and are included in the supply price. Type tests are carried out against request in our test room and are debited. These tests can be witnessed from customer-customer representative. Special tests are made at CESI laboratories in Milano and debited at cost.

TRASFORMATORI DI POTENZA IN OLIO OIL POWER TRANSFORMERS I trasformatori sono costruiti secondo gli standards: IEC 60076-13 o IEEE C57.12.01 (o altri standards a richiesta). Il nucleo è realizzato con lamierino magnetico ad alta permeabilità e bassa cifra di perdite, a gradini, taglio a 45 montaggio step-lap, con canali di raffreddamento. I conduttori degli avvolgimenti sono tutti in rame elettrolitico E-CU 99,9%. In base al disegno del trasformatore, gli avvolgimenti possono essere continui a disco trasposto, a elica semplice o multipla. I canali di raffreddamento sono fatti con stecche adeguatamente formate e anelli di guida del flusso. La commutazione sul primario è fatta sia a vuoto che con commutatore sotto carico. Gli avvolgimenti sono essiccati in autoclave per raggiungere l'esatta dimensione ed evitare successive inelastiche rotture o ritiri. Il trasformatore è incassato e riempito d'olio in condizioni di vuoto. La cassa è normalmente del tipo sottovuoto. Il raffreddamento avviene con i radiatori del tipo imbullonatostaccabile; solo in alcuni casi è utilizzato il tipo saldato. Per incrementare la potenza si utilizzano ventilatori o pompe di circolazione forzata olio. I trasformatori possono operare a una potenza superiore alla nominale in base a quanto definito nelle norme IEC 354. Quando problemi di dimensione non permettono di spedire il trasformatore con il liquido isolante, la cassa viene riempita con gas inerte; oppure si possono spedire i radiatori ed il conservatore staccati. I trasformatori si possono dotare di accessori specifici oltre a quelli di serie, come valvola di sovrappressione, conservatore con membrana, trasformatori amperometrici, immagine termica, cassonetti di protezione, cassetta di centralizzazione etc. The transformers are built in compliance with IEC 60076-13 standards and, IEEE C57.12.01 (or other on request). The core is made of high permeability cristal oriented steel sheet low loss, in a step section with 45 joints step-lap assembly, and is fitted with cooling channels. The winding conductors are all made of E-CU 99,9% electrolytic copper. According to the design of the transformer, windings can be continous or interleaved disc, simple or multiple elix. Cooling channels are made with duly shaped rods and flow guide rings. Tappings are provided on the HV windings, controlled either by means of an off circuit switch or an on load tap changer. The windings are dried in autoclave in order to reach exact dimensions and avoid successive inelastic failure. The complete transformer is closed in the tank and filled with oil in vacuum conditions. The tank is normally of the vacuum type. Cooling is made by means of tank mounted radiators: mainly used are the bolt on, detachable type; some times welded solution is used. The units can be fitted with fans or pumps to increase the rating of the transformer. The transformers are capable of operation at output in excess of nominal rating in accordance with IEC 354. When dimensional considerations do not permit unit to be dispatched with insulating liquid, arrangements are made for filling the transformer tank with inert gas, or the dispatching of radiators and conservator detached. The transformers can be equipped with specific accessories in addition to standard ones, such as overpressure valve, conservator with diaphragm, current transformers, winding temperature indicator, cable box, centralisation - marshalling box etc. La messa in funzione sul luogo di utilizzo può essere fatta con nostro personale specializzato. When required, on site erection can be carried out by our skilled personnel.

TRASFORMATORI IMMERSI IN OLIO CON COMMUTATORE A VUOTO OIL IMMERSED TRANSFORMERS WITH NO LOAD TAP CHANGER 20 MVA - NUCLEO MAGNETICO - MAGNETIC CORE COMMUTATORE A VUOTO Il commutatore a vuoto serve a variare il rapporto di trasformazione sul lato M.T. a trasformatore disattivato e per gradini fissi (ad esempio 2,5%). Se necessario il comando della commutazione può essere rimandato a lato cassa invece che sul coperchio, con attivazione manuale o motorizzata. PARTE ESTRAIBILE - ACTIVE PART TRASFORMATORE MONTATO - ASSEMBLED TRANSFORMER CASSA A RADIATORI STACCABILI - TANK WITH DETACHABLE RADIATORS NO LOAD TAP CHANGER The no load tap changer serves to vary the transforming ratio on M.V. side with the transformer out of duty and with fixed steps (for instance 2,5%). If necessary, the handle of the tap-normally on the cover-can be placed on tank side, with manual or motorised drive.

TRASFORMATORI IMMERSI IN OLIO CON COMMUTATORE SOTTO CARICO OIL IMMERSED TRANSFORMERS WITH ON LOAD TAP CHANGER 16 MVA kv 33 ± 9X1,25% COPERCHIO - COVER COMMUTATORE SOTTO CARICO Il commutatore sotto carico serve a variare il rapporto di trasformazione con trasformatori in servizio e fornisce una regolazione continua. I commutatori sotto carico installati nei nostri trasformatori di potenza sono prodotti dalla Maschinenfabrik Reinhausen, fornitore di commutatori sotto carico di concezione tecnicamente molto evoluti. Il commutatore sotto carico è attivato da una unità motore. L albero di comando e un rimando a squadra collegano meccanicamente il motore al commutatore. Un regolatore di tensione automatico viene usato per registrare le variazioni di tensione ed attivare il comando motore. 16 MVA kv 33 ± 9x1,25% PARTE ESTRAIBILE - ACTIVE PART ON LOAD TAP CHANGER The on load tap changer (OLTC) serves to vary the radio of transformer with the transformer on duty providing uninterrupted voltage regulation. The OLTC installed in our power transformers are manufactured by Maschinenfabrik Reinhausen, supplier of technically advanced OLTC. The on load tap changer is activated by a motor drive. Drive shafts and bevel gear units machanically connect the motor-drive to the on load tap changer. An electronic voltage regulator is used for sensing the voltage variation and to operate automatically the motor drive. COMMUTATORE SOTTO CARICO ON LOAD TAP CHANGER COMANDO MOTORE MOTOR DRIVE REGOLATORE DI TENSIONE ELETTRONICO ELECTRONIC VOLTAGE REGULATOR

TRASFORMATORI DI POTENZA IN RESINA I trasformatori sono costruiti secondo gli standards: IEC 60076-11 o IEEE C57.12.01 (o altri standards a richiesta). CAST RESIN POWER TRANSFORMERS The transformers are built in compliance with IEC 60076-11 standards and, IEEE C57.12.01 (or other on request). Il nucleo è costruito impiegando lamierini magnetici a cristalli orientati a bassa cifra di perdita ed elevata permeabilità. E realizzato con sezione a gradini, taglio a 45 step-lap calcolato per ottenere un minimo flusso residuo, una ridotta corrente d inserzione e un basso livello sonoro, ridotte perdite a vuoto. Un preciso assemblaggio e relativo ammaraggio finale assicurano l uniformità del complesso e garantiscono un tasso minimo di vibrazioni e le caratteristiche ottimali della struttura. Basi componibili in resina e supporti ad alta resistenza sono usati per fissare nella loro sede bobine primarie e secondarie. Le bobine di BT sono realizzate con lastra interavvolta di alluminio, con isolamento d interstrato in materiale di classe H. Questo tipo di avvolgimento assicura la migliore tenuta in relazione agli sforzi elettrodinamici. Le bobine vengono poi impregnate in resina epossidica per assicurare un elevato grado di protezione da agenti inquinanti. Le bobine di MT sono realizzate con bandelle di alluminio interavvolte e sovrapposte in serie. Le prese di regolazione sono disposte in maniera simmetrica in modo da evitare scompensi di amperspire. L isolante utilizzato è in classe F. L incapsulaggio delle bobine di MT, fase fondamentale di tutto il processo produttivo, viene eseguito grazie all azione combinata di temperatura e vuoto, utilizzando autoclave e forni autoventilati. Tutto il ciclo è dotato da un sistema di acquisizione dati che monitorizza e controlla temperatura, livello di vuoto e umidità residua. The core is made of cold rolled oriented grain steel sheet with low specific loss, cut at 45 C, step-lap, assembled at interleaved joints, with high care. It is calculated to obtain the minimum residual flux, reduced inrush current, low noise, low iron loss. The precise assembling and correct tightening guarantee an uniform stiffness and prevent vibrations so determining the optimal characteristic of the core itself. Resin cast composable bases and supports of high resistance are used to keep fasten in their seats primary and secondary coils. The LV windings are made in aluminium foil with insulation material in class H: this technology assures an high resistance to electrodynamic efforts. The coils are then impregnated with polymerized resins in the oven to guarantee high protection against pollution. The MV windings are made with aluminium foil strip, in subcoils connected in series; the tapping are designed symmetrically, in order to avoid unbalance of amp/turn. The casting of the HV windings, fundamental phase in the whole production system, is obtained with the combined action of vacuum and temperature. The complete process is controlled and monitored with a computerized system of data acquisition which allows the respect of the parameters needed for the achieving of a product with high quality standards. Tutti gli avvolgimenti possono essere anche realizzati in rame. The windings can be made with copper.

TRASFORMATORI IN RESINA CON DUE AVVOLGIMENTI IN PARALLELO CAST RESIN TRANSFORMERS WHIT TWO PARALLEL WINDINGS 10 MVA - NUCLEO MAGNETICO STEP-LAP - 10 MVA - STEP-LAP MAGNETIC CORE NUCLEO CON AVVOLGIMENTI BT/MT - MAGNETIC CORE WITH LV/MV WINDINGS TRASFORMATORE LATO BASSA TENSIONE - TRANSFORMER LOW VOLTAGE SIDE TRASFORMATORE LATO MEDIA TENSIONE - TRANSFORMER MEDIUM VOLTAGE SIDE

10-12,5 MVA 69 kv 6-7,25 MVA 11 kv 6,2 MVA 20/6 kv 4 MVA 20/3-12 kv 30 MVA 33 kv T.B.P. 04 09-12