Convertitori di interfaccia e software Interface transducers and software



Похожие документы
Convertitori di interfaccia e software Interface transducers and software

Convertitori di interfaccia e software Interface transducers and software

INTERFACCIA ETHERNET ETHERNET INTERFACE

MB-PULSE 4 Product Manual MB-PULSE 4 Manuale Prodotto

Vendite Italia: - Vendite Estero: - Ufficio Acquisti: - Ufficio Qualità:

TABELLA COMPARATIVA STRUMENTI DUCATI

CONVERTITORI DI INTERFACCIA E SOFTWARE Interface transducers and software

Copyright 2012 Binary System srl Piacenza ITALIA Via Coppalati, 6 P.IVA info@binarysystem.eu

MD2208. Multi I/O Control Module D32305 Rev. B. Microdata Due Martec Group

Dimensioni 101mm x 71mm x 28mm (H) Alimentazione Vac/Vcc Morsettiera o alimentatore plug, o da porta USB Connessioni lato RS232 e USB

QUBO & QUBO H. ANALIZZATORI DI RETE 72x72 mm 72x72 mm NETWORK ANALYSERS

MANUALE UTENTE. Gateway DLMS-MODBUS per ITRON/ACTARIS SL7000 con RS232 P/N: GW-DLMS-232-SL7. Edizione 2.0

MANUALE UTENTE. Gateway DLMS-MODBUS per LANDIS&GYR E650 con RS485 P/N: GW-DLMS-485-LG. Edizione 2.0

MANUALE UTENTE. Gateway DLMS-MODBUS per LANDIS&GYR E650 con RS232 P/N: GW-DLMS-232-LG. Edizione 2.0

MOSAIC MOR4/MOR4S8 RELAY OUTPUT EXPANSION UNIT

DENEB KNX. KNX RF S-Mode USB gateway interface / Interfaccia USB Gateway KNX RF S-Mode

TABELLA COMPARATIVA STRUMENTI DUCATI

PUMP CONTROLLER PUMP ACTIVE CONTROLLER

EML-16 EML-16. Pulses concentrator. Concentratore impulsi MODBUS COMMUNICATION PROTOCOL PROTOCOLLO DI COMUNICAZIONE MODBUS

TLR05S-350. Extender in corrente costante, 3 x 350mA per TLR04M_

WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]

QUBO 96 ANALIZZATORI DI RETE MULTIFUNZIONE MULTIFUNCTION NETWORK ANALYSERS

WIN 3 / ETHERNET. Amplificatore digitale per celle di carico con interfaccia ETHERNET... ITALIANO [Pag. 2-3]

Downloading and Installing Software Socio TIS

- ITALIANO - L inverter dispone al suo interno di due archivi separati: uno per le misure istantanee e uno per la produzione energetica.

Manuale per il collegamento e l uso Installation and operation manual

MANUALE UTENTE P/N: GW-IMP-WEB-1(-S) Edizione 1.0

WIN 3 / ANA SAEL S.R.L. Load cells digital amplifier...english [Pag ] Amplificatore digitale per celle di carico...italiano [Pag.

Amperorametro Amperhour meter Contatore Energy meter. Corrente di base Ib Basic current Ib INGRESSI INPUTS. Tensione nominale Un Nominal voltage Un

SOFTWARE ED INTERFACCE

TRF. Trasmettitore di peso wireless Weight transmitter wireless

the easy solution for Smart Metering

CABIN CREW TRAINING COMMUNICATION

Enel App Store - Installation Manual - Mobile

INTECNO TRANSTECNO. MICRO Encoder ME22 ME22 MICRO Encoder. member of. group

SRT064 BTH SRT051 BTH SRT052 BTH

Management software for remote and/or local monitoring networks

Expansion card. EXP-D8-120 I/O Interface Card 8 AC Opto-coupled Digital Inputs 8 DC Digital Outputs

IO LOG SIELCO SISTEMA DI ACQUISIZIONE DATI CARATTERISTICHE PRINCIPALI DESCRIZIONE GENERALE SISTEMI

PROTOCOLLO DI COMUNICAZIONE MODBUS MODBUS COMMUNICATION PROTOCOL. MANUALE ISTRUZIONI / INSTRUCTION MANUAL IM163-IU v0.61

User Manual. Rev Date: 31/05/2018

ET-NOVANTA6. Analizzatore di rete Multifunzione monodirezionale monofase e trifase. T Descrizione prodotto

Guida utente User Manual made in Italy Rev0

PG5 Starter Training Applicazione File System Daniel Ernst EN Stefano Peracchi IT

SOMMATORE / SOTTRATTORE - SEPARAZIONE GALVANICA

Features Operating Frequency: 860 to 960 MHz (software. Benefits Small size & Low cost Short Range UHF Controller

CONVERTITORE DI MISURA DI CORRENTE o TENSIONE o FREQUENZA o POTENZA VERO VALORE EFFICACE MONOFASE ALIMENTAZIONE SEPARATA MONTAGGIO GUIDA DIN

Design, Quality & Production Made in Italy GENERATORI D ARIA. Scheda Tecnica Data Sheet. Caldaie Termostufe Termocamini Stufe

SAIR NICOTRA-GEBHARDT-FAN.RU ELETTROVENTILATORI CENTRIFUGHI A SEMPLICE ASPIRAZIONE DIRETTAMENTE ACCOPPIATI DIRECT DRIVEN SINGLE INLET CENTRIFUGAL FANS

MOC10982 Supporting and Troubleshooting Windows 10

SAIR ELETTROVENTILATORI CENTRIFUGHI A SEMPLICE ASPIRAZIONE DIRETTAMENTE ACCOPPIATI DIRECT DRIVEN SINGLE INLET CENTRIFUGAL FANS

EVF is a range of controllers with elegant design for the management of refrigerated

REGISTRATION GUIDE TO RESHELL SOFTWARE

DICHIARAZIONE DI CONFORMITA' / Declaration of Conformity

LEGEND UPDATE GUIDE INSTALLING LEGEND UPDATE. viscount. Legend Update Guide

19 touchscreen display

MODALITA DI IMPIEGO PD

controlli di livello capacitivi capacitive levels controls

CONFIGURATION MANUAL

21/09/2015 SISTEMI E RETI. Router Cisco. Parte 1 - Introduzione. A cura dell Ing. Claudio Traini

PLC2 ELECTRONIC BOARD SCHEDA ELETTRONICA PLC2

Gateway Bacnet Multichiller series

ANALIZZATORI DI RETE COMPATTI COMPACT MULTIFUNCTION NETWORK ANALYSERS

la soluzione di monitoraggio dei consumi pensata per le aziende

EMI-10L Introduzione Il convertitore EMI-10L permette di convertire una porta di comunicazione seriale RS485 in un bus ethernet con protocollo TCP/IP.

Mod INTERFACCIA ETHERNET ETHERNET INTERFACE. Sch./Ref. 1067/007

Istruzioni per il trasferimento di dati dal fotometro Lovibond PoolDirect / MultiDirect SpectroDirect / PCSPECTRO II

Транскрипт:

Convertitori di interfaccia e software Interface transducers and software

MCILAN485G ETHERNET LAN GATEWAY ETHERNET LAN GATEWAY interfaccia Ethernet Ethernet interface IEEE802.3, IEEE802.3u velocità speed 10/100 Mbps connessione connection 1 x RJ-45 interfaccia seriale serial interface RS 485 Master connessione connection morsetti a vite / terminal blocks stop bits stop bits 1, 2 parity bits parity bits odd, even, none baud rate baud rate 9600, 19200, 38400 bps segnali data signals RS485: Data+, Dataprotezione ESD ESD protection 15 kv alimentazione power supply da/from 80 a/to 260V AC/DC MCILAN485G32H Il LAN gateway FRER permette di collegare ad una rete Ethernet (usando un solo indirizzo IP) fino a 32 dispositivi FRER dotati di interfaccia RS485. Esso può essere utilizzato nel caso in cui gli strumenti FRER non dispongano di interfacciamento Ethernet integrato, o per modificare in un secondo tempo il tipo di interfacciamento originale. Il LAN gateway FRER mette a disposizione dell'utente due possibili modi di funzionamento (anche contemporanei tra loro): 1. Conversione dal protocollo Modbus/TCP a Modbus RTU 2. Web-server integrato con le seguenti funzionalità: - Ricerca e riconoscimento automatico di tutti i dispositivi FRER ad esso collegati -Visualizzazione delle grandezze misurate da ogni singolo strumento collegato (una pagina per ogni strumento). - Data logging (in opzione), su memoria flash interna (16MB), di max 256 variabili selezionabili tra quelle fornite da tutti gli strumenti collegati, con tempo di campionamento impostabile e possibilità di programmazione della data e ora di inizio e fine registrazione. - Download in formato CSV del file contenente la registrazione sopra menzionata. Inoltre, attraverso opportune impostazioni del router di rete, Il LAN gateway FRER può essere reso accessibile tramite Internet, consentendo all'utilizzatore di visualizzare e registrare le misure effettuate dagli strumenti con un semplice browser e da qualsiasi parte del mondo. The FRER lan gateway allows to connect to an Ethernet network (using a single IP address) up to 32 FRER devices fitted with RS485 interface. It can be used in case the FRER instruments do not have integrated Ethernet interface, or to change the interface at a later stage. The FRER lan gateway provides the user two different kind of operation (also contemporary): 1. Conversion from Modbus / TCP to Modbus RTU 2. Web-server with the following features: - Research and automatic recognition of all the FRER devices connected to the gateway - Display of the measurement of each connected instrument (one page for each instrument). - Data logging (optional), in an internal flash memory (16MB), of up to 256 variables selected from those provided by the linked instruments with selectable sample time, and programmable start and stop recording date and time. - Download CSV file containing the above mentioned record. In addition, through appropriate settings of the network router, the FRER lan gateway can be accessible via Internet, allowing the user to view and record the measurements made by instruments with a simple browser from anywhere in the world. 1.2

MCILAN485I INTERFACCIA ETHERNET CON PROTOCOLLO IEC61850 ETHERNET INTERFACE WITH IEC61850 SUBSTATION PROTOCOL interfaccia Ethernet Ethernet interface IEEE802.3, IEEE802.3u velocità speed 10/100 Mbps connessione connection 1 x RJ-45 interfaccia seriale serial interface RS 485 Master connessione connection morsetti a vite / terminal blocks stop bits stop bits 1, 2 parity bits parity bits odd, even, none baud rate baud rate 9600, 19200, 38400 bps segnali data signals RS485: Data+, Dataprotezione ESD ESD protection 15 kv alimentazione power supply da/from 80 a/to 260V AC/DC MCILAN485I32H : La nuova norma internazionale IEC61850 definisce un protocollo di comunicazione orientato alla supervisione, controllo e protezione dei sistemi di generazione, trasporto e distribuzione dell'energia elettrica. Queste sono alcune delle sue caratteristiche principali: Un unico protocollo utilizzabile in tutti i livelli dell'impianto, da quello di campo a quello di supervisione. Una alta standardizzazione ed una accurata e chiara definizione delle funzioni e dei servizi coinvolti. L'adozione della rete Ehternet come mezzo di trasmissione, mantenendo comunque la possibilità di evolvere verso altri mezzi. I vantaggi offerti quindi da tale protocollo sono molti, e tra questi: I singoli utenti (dispositivi) comunicano tra loro, sia all'interno di un livello sia tra livelli differenti, utilizzando un unico protocollo comune. I dispositivi di produttori differenti e con funzioni differenti possono comunicare tra loro senza difficoltà. L'infrastruttura di rete esistente può essere riutilizzata, e quella nuova può essere condivisa con altre fun zioni/servizi. I dispositivi FRER dotati di tale protocollo sono pienamente conformi alle edizioni 1 e 2 dello standard IEC61850, e forniscono le seguenti misure (nodi logici) mappati su protocollo MMS: MMXU (Misure istantanee): Valori istantanei di tensione, corrente, potenze, fattore di potenza, frequenza. MHAI (Armoniche): THD di tensioni di fase e correnti di linea. MMTR (Conteggi energie): Energia attiva e reattiva totali bidirezionali. MSQI (Sequenza fasi): Sequenza fasi. MSTA (Valori medi e punte massime): Valore medio di Corrente e Potenza e Valori massimi delle medie misurate. : The new International Standards IEC61850 defines a communication protocol oriented to the supervision, control and protection for the generation systems, transmission and distribution of electricity. These are some of the main characteristics: Just one protocol for all system levels, from the field level to the supervision level. A high standardization and an accurate and clear definition of the functions and of the services involved. The use of the Ethernet network as transmission medium, while still maintaining the ability to evolve towards other means. The advantages of this protocol are so many, among them: Individual users (devices) communicate with each other, both within the same level and between different levels, by using a single common protocol. The devices from different manufacturers and with different functions can communicate with each other without any difficulty. The existing network infrastructure can be reused, and the new one can be shared with other functions / services. The FRER devices fitted with this protocol are conform to the issues 1 and 2 of the IEC 61850 standards. They provide the following measures (logical nodes) mapped to MMS protocol: MMXU (Istantaneous measurements): Instantaneous values of Voltages, Currents, Powers, Power factors, Frequency. MHAI (Harmonics): THD of phase voltages and line currents. MMTR (Energy counting): Total active and Reactive energy, both incoming and outgoing. MSQI (Phase sequence): Phases sequency. MSTA (Average & Peak values):average active power and currents, maximum value of average active power and currents. 1.3

MCIUSB485 CONVERTITORE DI INTERFACCIA USB - RS485 USB - RS485 INTERFACE CONVERTER baud rate baud rate up to 500kbps isolamento insulation 2500Vac connessione USB USB connection USB-B connessione RS485 RS485 connection morsettiera / screw terminals alimentazione power supply USB-Powered consumo power consumption 0,75W max. (150mA max.) temperatura di funzionamento operating temperature -10 +70 C temperatura di magazzinaggio storage temperature -25 +85 C MCIUSB485 Il convertitore di interfaccia cod. MCIUSB485 consente di collegare ad un PC, PLC o sistema di supervisione con interfaccia USB 2.0, fino a 32 strumenti di misura o altri dispositivi * con interfaccia RS485, indipendentemente dal protocollo utilizzato, ad una distanza massima di 1200 metri. Il convertitore effettua in modo automatico la commutazione trasmissione / ricezione sul lato RS485 e fornisce l'isolamento galvanico tra i due lati, indispensabile per un funzionamento sicuro ed affidabile della linea di comunicazione. Inoltre è già dotato internamente delle resisteze di terminazione e di polarizzazione della linea RS485. * Nota: Se gli strumenti/dispositivi sono dotati di Transceiver con carico ridotto, allora il numero di dispositivi collegabili aumenta corrispondentemente (Es. 1/4 unit Load = max. 128 Strumenti The interface converter cod MCIUSB485 is used to connect to a PC, PLC or supervision system with USB 2.0 interface, up to 32 measuring instruments or other devices* with RS485 interface, with any protocol and at a maximum distance of 1200 meters. The converter automatically handles the transmit / receive switching on the RS485 side and provides the galvanic insulation between the opposite sides in order to guarantee a safe and reliable operation of the communication line. Moreover the termination and the polarization resistances of the RS485 line are fitted inside the converter. * Remark: if the meters/devices are fitted with reduced load transceiver the meters/devices quantity which can be wired increases (1/4 unit load = max. 128 meters) ACCESSORI IN DOTAZIONE Adattatore per montaggio su guida DIN SUPPLIED ACCESSORIES DIN rail mounting adapter 1.4

MCIN2O485 INTERFACCIAMENTO PROT. JOHNSON CONTROL N2 OPEN JOHNSON CONTROL N2 OPEN PROTOCOL INTERFACE interfaccia interface RS485 isolata/insulated velocità speed 9600 bps parità parity none campo di indirizzamento addressing range 1...247 programm. MCIN2O485 MCIN2O485 è un modulo di intefacciamento esterno per collegare uno strumento multifunzione FRER (dotato di intefaccia RS485 con protocollo ModBus RTU) ad un sistema con protocollo Johnson Controls N2 Open. Può essere utilizzato nei casi in cui non sia previsto l interfacciamento integrato nel prodotto, o per modificare in un secondo tempo il tipo di interfacciamento originale. The MCIN2O485 is an external interfacing unit which permits to connect a FRER multifunction meter (fitted with RS485 interface and ModBus RTU protocol) to a Johnson Controls N2 Open protocol system. This device can be used either in those cases where the product integrated in interfacing is not foreseen or to modify the original interfacing type. MCIPRO485 MODULO DI INTERFACCIAMENTO PER PROFIBUS DP V0 PROFIBUS DP V0 INTERFACE MODULE rete network NRZ asincrona/asynchronous baudrate baudrate 9,6kbit/s...12Mbit/s campo di indirizzamento addressing range 1...99 programm. conforme a complies to EN 50170 MCIPRO485 MCIPRO485 è un modulo di intefacciamento esterno per collegare uno strumento multifunzione FRER (dotato di intefaccia RS485 con protocollo ModBus RTU) ad un sistema ProfiBus DP V0 Può essere utilizzato nei casi in cui non sia previsto l interfacciamento integrato nel prodotto, o per modificare in un secondo tempo il tipo di interfacciamento originale. The MCIPRO485 is an external interfacing unit which permits to connect a FRER multifunction meter (fitted with RS485 interface and ModBus RTU protocol) to a ProfiBus DP V0 protocol system. This device can be used either in those cases where the product integrated in interfacing is not foreseen or to modify the original interfacing type. 1.5

6SFV02... FRER VIEW, programma di supervisione analizzatori FRER VIEW, monitoring program for network analysers sistemi operativi operating system Windows 98, 2000, XP velocità selezionabile selctable speed 9600-14400-19200-38400 bps porta seriale selezionabile selectable serial port Com1, Com2, Com3, Com4 campo di indirizzamento(id) addressing range (ID) 1 64 TIPO - TYPE max. 3 strumenti / instruments max. 16 strumenti / instruments max. 64 strumenti / instruments 6SFV02003 6SFV02016 6SFV02064 Il FRER VIEW è un programma di monitoraggio e supervisione in grado di visualizzare in formato numerico e grafico tutte le misure elettriche rilevate da uno o più Analizzatori di rete FRER con uscita seriale RS485. Dalla finestra principale è possibile: - accedere al menù di configurazione del programma - accedere al menù diconfigurazione degli strumenti - monitorare 9 misure elettriche selezionabili di 3 analizzatori contemoporaneamente - visualizzare un grafico a nove curve (con parametri e campo scala configurabile) - abilitare reports - attivare l archivio storico Per quest ultimo è inoltre possibile accedere ad un programma di visualizzazione grafica delle misure archiviate. La gestione del programma è protetta da 2 PassWord (Amministratore e Utente); in fase di configurazione è possibile stabilire chi può accedere alle varie fasi di programmazione/gestione. The FRER VIEW software is a monitoring and supervision program which permits to display either as numerical or as graphic format all electrical measurements coming from FRER multifunction network analysers fitted with RS485 serial output. The main window permits the access to the following functions: - program configuration menu - meter configuration menu - monitoring of 9 electrical measurements coming from 3 different meter (contemporary) - nine curves graphic display (parameters and scale range are configurables) - reports activations - historical file activation The historical file permits also to enter a graphic visualization program of the stored measurements. The access to the program is protected by 2 PassWord (Administrator and User). The configuration procedure permits to define the access to the various steps of the programming/handling functions. 1.6

6SFE... FRER ENERGY, supervisione contatori di energia FRER ENERGY, monitoring program for energy meters sistemi operativi operating system Windows 98, 2000, XP velocità selezionabile selctable speed 9600-14400-19200-38400 bps porta seriale selezionabile selectable serial port Com1, Com2, Com3, Com4 campo di indirizzamento (ID) addressing range (ID) 1 247 campionamento selezionabile selectable sampling 1h, 3h, 6h, 12h lettura energia energy reading kwh TIPO - TYPE max. 64 contatori di energia / energy meters max. 256 contatori di energia / energy meters 6SFE01064 6SFE01256 Il FRER ENERGY è un programma di supervisione in grado di comunicare, visualizzare, memorizzare e stampare i consumi diretti, totalizzati in kwh, dell energia elettrica misurata da contatori di energia FRER con uscita seriale RS485 o con uscita impulsiva (tramite concentratori di impulsi). Il programma è in grado di monitorare un totale di 72 o 288 contatori (a seconda della versione). Per collegare un maggiore numero di strumenti, per esempio 1152 strumenti, è sufficiente mandare in esecuzione per 4 volte lo stesso software configurando ogn'uno di questi con una diversa porta di comunicazione seriale (es. Com1, Com2, Com3, Com4). Dal menù principale si può accedere ad una finestra formata da una mappa importabile nel programma in formato.bmp su cui è possibile posizionare le icone rappresentanti i contatori. Cliccando su una di queste icone si accede direttamente alla finestra di gestione del contatore specifico (contenente i dati del contatore, del cliente e i consumi in tempo reale) La gestione del programma è protetta da 2 PassWord (Amministratore e Utente); in fase di configurazione è possibile stabilire chi può accedere alle varie fasi di programmazione/gestione. Il FrerEnergy può effettuare inoltre tre tipi di archiviazione in formato di testo: Report Generale, Archiviazione Utenza e Archiviazione del Programma. The FRER ENERGY software is a monitoring program which permits to display, to store, to transmit and print the electrical energy consumptions counted by FRER energy meters fitted with RS485 serial output or with pulse output by means of pulse concentrators. The FRER ENERGY is available in two versions: the first one permits to monitor up to 72 meters while the second one up to 288 meters. It is possible to connect a higher quantity of meters than 288 pieces. Example: to connect 1152 meters it is necessary to execute 4 times the same software by configuration each software to different communication serial port (com1, com2, com3, com4). From the main menu it is possible to access a map window importable as a.bmp format. On the map it is possible to locate the Energy meters icons. By clicking the energy meters icon the energy meter monitoring window is opened. The monitoring window shows the energy meter details, the customer details and the real time energy consumption. The program is protected by 2 PassWord (Administrator and User). it is possible to define the access level to the different program steps during the program configuration procedure. Records: 3 text format reports are available. They are: General Report, User records and Program records. 1.7