SIMATIC WinCC Runtime Professional ARCHITETTURE. Versione 1.0 03/2014



Documenti analoghi
SIMATIC WinCC Runtime Professional ARCHITETTURE. Versione /2013

SIMATIC WinCC Runtime Professional V13 SP1 ARCHITETTURE. Versione /2015

SIMATIC WinCC Runtime Professional V11 SP2 ARCHITETTURE. Versione /2012

SIMATIC WinCC V7.0 SP3

HMI: WinCC. Service Pack 2 per SIMATIC Maintenance Station 2009 (Customer Support ID: )

SIMATIC WinCC V7.3 ARCHITETTURE. Versione /2014

WinCC V11 (TIA Portal)

SIMATIC WinCC V7.2. Versione /2013

SIMATIC WinCC V7.0 SP3. Versione /2012

SIMATIC WinCC V7.2. Versione /2013

Nr. 2016/2.2/45 Data: WinCC. SIMATIC WinCC V7.4 Siemens Customer Support (Entry-ID: )

Nr. 2011/1.5/61 Data: PLC: STEP7 V11. Service Pack 2 per STEP7 Basic & Professional V11.

Nr. 2011/2.2/15 Data: HMI: WinCC

SIMATIC WinCC V7.0 SP1 COMUNICAZIONE CON PLC S7. Versione /2009

Industry Automation. HMI: WinCC. SIMATIC WinCC PerformanceMonitor V7.2

SIMATIC WinCC V7.2. Versione /2014

INFO ESTERNA Industry sector

Rilascio WinCC V15 10.gennaio. 2018

SIMATIC WinCC V7.3 SE ARCHITETTURE. Versione /2015

Novità Servicepack 1 per STEP7 V11 TIA Portal V11. Siemens AG All Rights Reserved.

SIMATIC WinCC V7.5 ARCHITETTURE. Unrestricted

3. Il client HMI, che consente la visualizzazione delle informazioni e riceve dall'utente l'input da inviare al controllore. SLC

Siemens ha il piacere di annunciare il rilascio alla vendita e alla distribuzione della nuova versione V7.0 dello SCADA SIMATIC WinCC.

NOTE OPERATIVE DI RELEASE

Note Tecniche Installazione ed Aggiornamento EasyTelematico 1.3.x

Scheda requisiti Hardware e Software

Note di rilascio. Aggiornamento disponibile tramite Live Update a partire dal. Il supporto per Windows XP e Office 2003 è terminato

Licenza per sito Manuale dell amministratore

Xerox Device Agent, XDA-Lite. Guida all installazione rapida

SIMATIC NET: Ethernet

IBM SPSS Statistics per Windows - Istruzioni di installazione (Licenza per utenti singoli)

IngEstate. Sistema di telegestione

2010 Ing. Punzenberger COPA-DATA Srl. Tutti i diritti riservati.

Nr. 2013/2.2/9 Data: HMI: WinCC. SIMATIC WinCC V7.2

SIMATIC HMI. INFO INTERNA HMI Nr.:2007/011/3.7 Data: 31/08/07

Scheda requisiti Hardware e Software per Arca Evolution ed Arca ego

- la possibilità di monitorare lo stato attuale della macchina - fornire una reportistica sulla base di alcune variabili

PORTALE CLIENTI Manuale utente

STORM OPEN SOLUTIONS E2KPos. Guida all'installazione

SIMATIC WinCC V7.5 ARCHITETTURE. Restricted

Installazione e caratteristiche generali 1

SIMATIC WinCC V7.3 SE ARCHITETTURE. Versione /2015

Procedura Gestione Pratiche Sicurezza Cantiere

Zoo 5. Robert McNeel & Associates Seattle Barcelona Miami Seoul Taipei Tokyo

SPSS Statistics per Windows - Istruzioni di installazione per (Licenza per utenti singoli)

SIMATIC NET: Collegamento a PC

Sistema di Monitoraggio e Controllo della Produzione di Materie Plastiche

SIMATIC NET: Collegamento a PC

Premessa Le indicazioni seguenti sono parzialmente tratte da Wikipedia ( e da un tutorial di Pierlauro Sciarelli su comefare.

IBM SPSS Statistics per Windows - Istruzioni di installazione (Licenza per sito)

TERMINALE. Creazione e gestione di una postazione terminale di Eureka

OLIDALMINE SISTEMI S.N.C. - via Buttaro 4/e Dalmine BG - Tel Fax info@olidalmine.it

VPN RETI PRIVATE VIRTUALI: ACCESSO REMOTO

IBM SPSS Statistics per Windows - Istruzioni di installazione (Licenza per utenti singoli)

Considerazioni sui server

MANUALE INSTALLAZIONE E CONFIGURAZIONE

La Prima Pagina rappresenta la scrivania dalla quale accedere alle principali funzionalità del servizio.

Architetture Informatiche. Dal Mainframe al Personal Computer

Installazione di GFI Network Server Monitor

TERMINE SUPPORTO DA PARTE DI MICROSOFT DEL SITEMA OPERATIVO WINDOWS XP: 8 Aprile 2014

ARCHIVIA PLUS VERSIONE SQL SERVER

Ti consente di ricevere velocemente tutte le informazioni inviate dal personale, in maniera assolutamente puntuale, controllata ed organizzata.

TIA Portal Welcome to the next level. Per uso interno / Siemens AG All Rights Reserved.

SIMATIC WinCC V7.4 SP1 ARCHITETTURE. Unrestricted

SEGNALIBRO NON È DEFINITO.

SurfCop. Informazioni sul prodotto

M.U.T. Modulo Unico Telematico

GUIDA ALL INSTALLAZIONE. Protezione di locale/rete. per il software CADPak su client e server di rete. per la Chiave Hardware Sentinel Hasp

Programma per l elaborazione delle buste paga. dei collaboratori domestici VERSIONE /07/2010

Nr. 2012/1.5/20 Data: PLC:S Nuova CPU S7-400H PN/DP con FW V6.0.

GSP+ Customer Relationship Manager V 7.0. Manuale utente

Manuale di Aggiornamento BOLLETTINO. Rel H4. DATALOG Soluzioni Integrate a 32 Bit

SIMATIC WinCC V7.4 SP1 ARCHITETTURE. Unrestricted

SIMATIC NET: ETHERNET

Istruzioni installazione mandato Informatico

DALL IMMAGINE AL TESTO...SEMPLICEMENTE

Aggiornamenti Sistema Addendum per l utente

Fiery Driver Configurator

Architetture Informatiche. Dal Mainframe al Personal Computer

Installazione di GFI LANguard Network Security Scanner

M.U.T. Modulo Unico Telematico

Maschere di sottorete a lunghezza variabile

AeMmag Software. (Gestione vendite e magazzino) Guida per l utente. Versione Manuale di utilizzo Stato: Definitivo

filrbox Guida all uso dell applicazione DESKTOP Pag. 1 di 27

lem logic enterprise manager

Manuale configurazione caselle di posta elettronica HME Standard

IBM SPSS Statistics - Essentials for R- Istruzioni di installazione per Windows

DOCUMENTAZIONE TECNICA

Software di gestione della stampante

Installazione del software Fiery per Windows e Macintosh

INTEGRATA OTTIMIZZAZIONE DEI PROCESSI AZIENDALI

Dipartimento delle Libertà Civili e l Immigrazione

Agent, porte, connettività e reti L agent di Kaseya utilizza la porta 5721 per comunicare con il server, ma che tipo di porta è?...

Requisiti minimi di installazione Novità Piattaforma CGN 2015: Piattaforma nominativa Piattaforma CGN 2014 non installata...

Office 365 Education Guida alla registrazione, al download e all installazione

Guida di Pro Spam Remove

Supporto On Line Allegato FAQ

Display Network Manager

NOTE TECNICHE DI CONFIGURAZIONE. Giugno 2009

Transcript:

SIMATIC WinCC Runtime Professional V13 ARCHITETTURE Ronald Lange (Inventor 2011) TIA Portal: Automation Software that Fits Together As Perfectly As Lego Blocks Versione 1.0 03/2014

- Architetture Novità Architetture possibili con WinCC Runtime Professional V13, basata sui codici di ordinazione di questa nuova versione. Introdotta l opzione WinCC Redundancy for WinCC Runtime Professional, novità della V13. Tutti i codici di ordinazione delle opzioni sono gli stessi di WinCC Runtime Professional V1/V12/V13, perché il software da installare è incluso nel DVD di WinCC e le licenze V13 sono retrocompatibili. WinCC V13 introduce la compatibilità con Windows 8.1 e Windows Server 2012 R2. Al contrario, Windows XP e Windows Server 2003 non sono più supportati. I client sono sempre di tipo client-senza-progetto Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 2

- Architetture Simboli utilizzati WinCC Stazione Singola PLC WinCC Server PC senza WinCC WinCC WinCC client standard DB Database esterno 123 Pacchetti sw necessari sulle varie stazioni Engineering Station Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 3

Sistemi Operativi Microsoft compatibili WinCC Stazione Singola e Client Windows 7 SP1 Professional, Enterprise o Ultimate - (32bit) Windows 7 SP1 Professional, Enterprise o Ultimate - (64bit) Windows 8.1 Professional o Enterprise - (64bit) Windows Server 2008 R2 StdE SP1 (64bit) (no per i WinCC Client) Windows Server 2012 R2 StdE (64bit) (no per i WinCC Client) WinCC Server Windows Server 2008 R2 StdE SP1 (64bit) Windows Server 2012 R2 StdE (64bit) Windows 7 (Max 3 WinCC Clients e no ridondanza) Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 4

Sistemi Operativi Microsoft compatibili per opzione Web Navigator WinCC Web Navigator Server istallato su Stazione Singola WinCC Windows 7 - (32/64 bit) (max. 3 Client) Windows 8.1 Professional o Enterprise - (64bit) Windows Server 2008 R2 StdE SP1 (64bit) Windows Server 2012 R2 StdE (64bit) WinCC/WebNavigator Server su WinCC Server Windows Server 2008 R2 StdE SP1 (64bit) Windows Server 2012 R2 StdE (64bit) WinCC/Web Navigator Client Windows 7 - (32/64 bit) Windows 8.1 Professional o Enterprise - (64bit) Windows Server 2008 R2 StdE SP1 (64bit) Windows Server 2012 R2 StdE (64bit) Mobile devices via RDP tramite i servizi a pagamento di Remote Desktop di Windows Server Windows Embedded su IPC 4x7 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 5

SIMATIC WinCC Professional V13 Engineering Numeri di ordinazione dei pacchetti base di sviluppo Ogni pacchetto di sviluppo include la simulazione locale del progetto. Non includono il software per istallazioni runtime (vedi slide successiva). WinCC Professional 512 Tag V13 WinCC Professional 4096 Tag V13 WinCC Professional Max. Tags (64k) V13 MLFB: 6AV2103-0DA03-0AA5 MLFB: 6AV2103-0HA03-0AA5 MLFB: 6AV2103-0XA03-0AA5 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 6

Numeri di ordinazione dei pacchetti runtime base Ogni pacchetto include 500 tag di archiviazione di variabili di processo (LoggingTags) espandibili tramite licenze di powerpack opzionali. Non includono il software di sviluppo (vedi slide precedente). WinCC Runtime Professional V13 RT 128 WinCC Runtime Professional V13 RT 512 WinCC Runtime Professional V13 RT 2048 WinCC Runtime Professional V13 RT 4096 WinCC Runtime Professional V13 RT 8192 WinCC Runtime Professional V13 RT 65536 WinCC Runtime Professional V13 Client MLFB: 6AV2105-0BA03-0AA0 MLFB: 6AV2105-0DA03-0AA0 MLFB: 6AV2105-0FA03-0AA0 MLFB: 6AV2105-0HA03-0AA0 MLFB: 6AV2105-0KA03-0AA0 MLFB: 6AV2105-0MA03-0AA0 MLFB: 6AV2107-0DB03-0AA0 WinCC Logging 1500 LoggingTags WinCC Logging 5000 LoggingTags Powerpack da 1500 a 5000 LoggingTags MLFB: 6AV2107-0GB00-0BB0 MLFB: 6AV2107-0GD00-0BB0 MLFB: 6AV2107-2GD00-0BD0 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 7

Numeri di ordinazione licenze WinCC WebNavigator WinCC WebNavigator 3 Client WinCC WebNavigator 10 Client WinCC WebNavigator 25 Client WinCC WebNavigator 50 Client WinCC WebNavigator 100 Client WinCC WebNavigator 150 Client 6AV2107-0KD00-0BB0 6AV2107-0KF00-0BB0 6AV2107-0KH00-0BB0 6AV2107-0KK00-0BB0 6AV2107-0KM00-0BB0 6AV2107-0KP00-0BB0 Powerpack WinCC WebNavigator da 3 a 10 Client Powerpack WinCC WebNavigator da 10 a 25 Client Powerpack WinCC WebNavigator da 25 a 50 Client Powerpack WinCC WebNavigator da 50 a 100 Client Powerpack WinCC WebNavigator da 100 a 150 Client 6AV2107-2KF00-0BD0 6AV2107-2KH00-0BD0 6AV2107-2KK00-0BD0 6AV2107-2KM00-0BD0 6AV2107-2KP00-0BD0 WinCC WebDiagnostics Server WinCC WebDiagnostics Client 6AV2107-0KR00-0BB0 6AV2107-0KT00-0BB0 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 8

Numeri di ordinazione licenze WinCC DataMonitor WinCC DataMonitor 1 Client WinCC DataMonitor 3 Client WinCC DataMonitor 10 Client WinCC DataMonitor 25 Client WinCC DataMonitor 50 Client 6AV2107-0LB00-0BB0 6AV2107-0LD00-0BB0 6AV2107-0LF00-0BB0 6AV2107-0LH00-0BB0 6AV2107-0LK00-0BB0 Powerpack WinCC DataMonitor da 1 a 3 Client Powerpack WinCC DataMonitor da 3 a 10 Client Powerpack WinCC DataMonitor da 10 a 25 Client Powerpack WinCC DataMonitor da 25 a 50 Client 6AV2107-2LD00-0BD0 6AV2107-2LF00-0BD0 6AV2107-2LH00-0BD0 6AV2107-2LK00-0BD0 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 9

Stazione Runtime Singola 1 WinCC RuntimeSingle Station 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione nelle pagine iniziali Limiti per WinCC Runtime Professional: Variabili di processo max: 80.000 (incluse le tag di archiviazione configurate in Tag Logging) Messaggi configurabili: 150.000 Max num. archivi: 100 Max num. tag configurabili in TagLogging: 80.000 [500 variabili di archivio nel pacchetto base] Utenti: 200 Per WinCC Runtime Professional collegato a S7-1200 verificare le limitazioni nel manuale di sistema. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 10

Stazione Singola Runtime + Sviluppo 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione nelle pagine iniziali 1 2 WinCC Single Station Runtime + Engineering 2 Licenza WinCC Professional Eng. Limiti per WinCC Runtime Professional: Variabili di processo max: 80.000 (incluse le tag di archiviazione configurate in Tag Logging) Messaggi configurabili: 150.000 Max num. archivi: 100 Max num. tag configurabili in TagLogging: 80.000 [500 variabili di archivio nel pacchetto base] Utenti: 200 Per WinCC Runtime Professional collegato a S7-1200 verificare le limitazioni nel manuale di sistema. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 11

Stazione Singola ridondante Stazioni singole ridondanti per maggiore disponibilità WinCC Single Station ridondante 2 1 1 Engineering Station 3 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione nelle pagine iniziali 2 Licenza Redundancy per WinCC RT Professional MLFB: 6AV2107-0FB00-0BB0 3 Licenza WinCC Professional Eng. Vedi codici di ordinazione nelle pagine iniziali Ulteriori informazioni: La Ridondanza sincronizza i massaggi, le variabili di processo e le ricette tra due stazioni WinCC. Un solo pacchetto WinCC Redundancy per 2 stazioni in ridondanza, in quanto sono incluse le 2 licenze che devono essere caricate su entrambe le macchine. N.B.: La stazione di ingegneria DEVE ESSERE SEPARATA. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 12

Sistema multi-utente Server centrale con client standard ed ingegneria separata 3 1..32 WinCC Clients Standard WinCC 3 WinCC 3 WinCC 3 WinCC Engineering Station 4 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione nelle pagine iniziali 2 Licenza Server per WinCC RT Professional MLFB: 6AV2107-0EB00-0BB0 1 2 WinCC Server 3 Licenza Client per WinCC RT Professional MLFB: 6AV2107-0DB03-0AA0 4 Licenza WinCC Professional Engineering Vedi codici di ordinazione nelle pagine iniziali Ulteriori informazioni: Ad un server WinCC è possibile collegare fino a 32 client se cieco, fino a 4 se è attiva la grafica. Sui WinCC client è necessario installare l apposita licenza WinCC RT Professional CLIENT In WinCC V13 è possibile configurare solo client di tipo standard o uni-client (no client con progetto o multi-client). Non è possibile il client-di-ingegneria. La stazione di ingegneria richiede il pacchetto di sviluppo con PowerTags sufficienti e non può essere configurata come client. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 13

Sistema multi-utente Server centrale con ingegneria sul server 3 1..32 WinCC Clients Standard WinCC 3 WinCC 3 WinCC 3 WinCC 1 2 4 WinCC Server + Engineering Station 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione nelle pagine iniziali 2 Licenza Server per WinCC RT Professional MLFB: 6AV2107-0EB00-0BB0 3 Licenza Client per WinCC RT Professional MLFB: 6AV2107-0DB03-0AA0 4 Licenza WinCC Professional Engineering Vedi codici di ordinazione nelle pagine iniziali NOTA BENE: E possibile utilizzare il server anche come ingegneria installando il pacchetto di sviluppo, ma in questo caso non è possibile compilare le modifiche con WinCC in runtime. Con la stazione di ingegneria separata, invece, è possibile effettuare modifiche, compilazioni e download senza fermare il server. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 14

Sistema multi-utente con Ridondanza per una maggiore disponibilità 1..32 WinCC Clients Engineering 1 Licenza WinCC RT Station Professional Base Vedi codici di ordinazione nelle 5 pagine iniziali 2 WinCC 2 WinCC 2 WinCC 2 WinCC 1 3 4 1 3 WinCC Server Ulteriori informazioni: Grazie alla ridondanza del server i client sono operativi anche dopo il guasto di uno dei 2 server. Dopo il ripristino i dati vengono sincronizzati tra i server. NOTA BENE: In caso di server ridondanti la stazione di ingegneria deve essere installata su una macchina dedicata e separata. Non può essere né uno dei server né un client. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 15 3 Licenza Client per WinCC RT Professional MLFB: 6AV2107-0DB03-0AA0 3 Licenza Server per WinCC RT Professional MLFB: 6AV2107-0EB00-0BB0 4 Licenza Redundancy per WinCC RT Professional MLFB: 6AV2107-0FB00-0BB0 5 Licenza WinCC Professional Eng. Vedi codici di ordinazione nelle pagine iniziali

Stazione Singola Runtime come Web server Collegare i client attraverso il Web 1 2 Web Clients WinCC RT Professional + WebNavigator/DataMonitor Server 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione in slide precedente 2 Licenza WebNavigator (n client) per WinCC RT Professional es: per 3 Client MLFB: 6AV2107-0KD00-0BB0 oppure 2 Licenza DataMonitor es: per 1 Client MLFB: 6AV2107-0LB00-0BB0 Ulteriori informazioni: WinCC WebNavigator fornisce la supervisione su rete LAN o Internet. WinCC Data Monitor viene utilizzato per l'analisi dei dati di processo attuali e storici, e li distribuisce tramite LAN o Internet. Il numero massimo di client web simultaneamente collegati allo stesso server è 150 per WebNavigator e 50 per DataMonitor. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 16

Sistema multi-utente con web server il server WinCC funge anche da server web 3 WinCC Standard Clients WinCC 3 WinCC Web Clients 4. 4 1 Licenza WinCC RT Professional Base Vedi codici di ordinazione in slide precedente 2 Licenza Server per WinCC RT Professional MLFB: 6AV2107-0EB00-0BB0 1 2 WinCCServer + WebNavigator 3 Licenza Client per WinCC RT Professional MLFB: 6AV2107-0DB03-0AA0 4 Licenza WebNavigator es: per 3 Client MLFB: 6AV2107-0KD00-0BB0 oppure Ulteriori informazioni: In configurazione mista (server WinCC anche server WebNavigator) è possibile collegare 32 standard client + 3 web client oppure 50 web client + 1 standard client. 4 Licenza DataMonitor es: per 1 Client MLFB: 6AV2107-0LB00-0BB0 Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 17

WebNavigator Diagnostics soluzione ideale per pochi web clients e svariati web servers 3 Web Diagnostics Clients 3 1 Licenza WinCC RT Professional Base WinCC Single Station + Web Diagnostics Server 1 2 1 2 1 2 Vedi codici di ordinazione in slide precedente 2 Licenza WebNavigator Diagnostics Server MLFB: 6AV2107-0KR00-0BB0 3 Licenza WebNavigator Diagnostics Client MLFB: 6AV2107-0KT00-0BB0 Progetto A Progetto B Progetto C Ulteriori informazioni: Nel caso di più progetti diversi che devono essere accessibili via web, e qualora sia sufficiente avere pochi web clients contemporaneamente attivi, questa soluzione è più economica di quella classica. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 18

WebNavigator Diagnostics Client soluzione per avere accesso sempre garantito. 1 3 1 3 1 WinCC pacchetto base 1 3 2 Web Diagnostics Client 1 3 2 WinCC/WebNavigator Diagnostics Client MLFB: 6AV2107-0KT00-0BB0 3 Licenza WebNavigator Diagnostics Server MLFB: 6AV2107-0KR00-0BB0 oppure 3 Licenza WebNavigator WinCC Web Servers con licenza WebNavigator Server (es. 3 clients) o WebNavigator Diagnostics Server es: per 3 Client MLFB: 6AV2107-0KD00-0BB0 Ulteriori informazioni: Il termine Diagnostics sta ad indicare una funzionalità di diagnostica dell impianto via web che deve poter aver luogo sempre indipendentemente dal limite di collegamenti imposto dalla licenza. Quindi anche se un WebNavigator Server con la licenza classica ha raggiunto il numero massimo di collegamenti consentiti dalla sua licenza, il client web di diagnostica riesce comunque a collegarsi ad esso. Inoltre un Web Diagnostics Client può collegarsi ad un numero qualsiasi di web servers. Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 19

Per maggiori informazioni: Leonetti Domenico WinCC Product Manager I IA AS HMI Tel: +39 02 24362884 E-Mail: domenico.leonetti@siemens.com Architetture per WinCC Professional Runtime V13 V1.0 del 03-2014 Pag. 20