La nuova edizione della norma ISO 13485:2016 (UNI CEI EN ISO 13485:2016)

Documenti analoghi
N 1 alla versione bilingue (italiano-inglese) NORMA UNI EN ISO 9001 (novembre 2008) Sistemi di gestione per la qualità - Requisiti.

Le future norme ISO dovrebbero rispondere alle ultime tendenze ed essere compatibili con altri sistemi di gestione.

ISO 9001:2015. Il processo di revisione 16/11/2014. Verso l ISO 9001:2015 gli steps del processo di revisione

Le norme della Qualità

ISO 9001:2015. Ing. Massimo Tuccoli. Genova, 27 Febbraio 2015

HSE Manager. L Integrazione delle analisi di rischio tipiche del ruolo con i processi di risk management aziendali

IL SISTEMA DI GESTIONE QUALITÀ A - LINEE ESSENZIALI SUPPORTO DELLA CERTIFICAZIONE DEI DISPOSITIVI MEDICI. SSFA / dic-2016

Verso l ISO 9001:2015 Opportunità e sfide per le imprese

LA NUOVA ISO 9001:2015

ISO/TC 210/WG 1 Application of quality systems to medical devices. wg1n233 Draft White Paper - ISO Transition Planning Guidance for ISO 13485:2016

ANALISI DEI PERICOLI Hazard Analysis

L audit in incognito rif. ISO/TS 11312

DICHIARAZIONE DI CONFORMITA' / Declaration of Conformity

Auditorium dell'assessorato Regionale Territorio e Ambiente

Università di Bergamo Facoltà di Ingegneria GESTIONE DEI SISTEMI ICT. Paolo Salvaneschi A9_1 V1.3. Misura

Rintracciabilità di Filiera dalla UNI10939 alla ISO 22005

DOMANDA PER IL RICONOSCIMENTO DEL LABORATORIO DI PROVA APPLICATION FOR ASSESSMENT OF TESTING LABORATORY

Sistemi elettronici per la sicurezza dei veicoli: presente e futuro. Il ruolo della norma ISO per la Sicurezza Funzionale

Tanta fatica solo per un bollino ne vale davvero la pena?

Sistemi di gestione per la qualità Requisiti

Antonio Menditto. Istituto Superiore di Sanità

La saldatura delle strutture metalliche nel quadro della EN 1090

Manuale del Sistema di Gestione per la Qualità del I.I.S. Liceo L. Anneo Seneca Manual of Quality Management System of I.I.S. L. Anneo Seneca Lyceum

no. SIC Rev. 00 Dated

Redazione Approvazione Autorizzazione all emissione Entrata in vigore. Il Direttore Generale

CERTIFICATO CE. Dichiarazione di approvazione del sistema qualità (Garanzia di qualità della produzione) Certificato n. 1670/MDD MACOSTA MEDITEA SRL

PREVENTION IS BETTER THAN CURE SOLO UNO SLOGAN?

ACCREDIA L Ente Italiano di Accreditamento

Rules for the certification of Information Security Management Systems

USER LICENSE LICENZA D USO


Verifica del rispetto dei requisiti essenziali Marcatura CE dei prodotti

COPYRIGHT NOTICE & TERMS OF USE

GIOVEDI 12 LUGLIO ORE 18.00

REPORT AUDIT DI DOSE PER STERILIZZAZIONE RAGGI BETA ELECTRON BEAM STERILIZATION VALIDATION REPORT

ACCREDIA L ENTE ITALIANO DI ACCREDITAMENTO

La qualità del farmaco sperimentale come partner indispensabile per la ricerca clinica

Rif. Draft International Standard (DIS)

LABORATORIO CHIMICO CAMERA DI COMMERCIO TORINO

ISO 9001:2015. L innovazione nei Sistemi di Gestione per la Qualità. Roma 23/10/15 Bollate 06/11/15

Ingegneria del Software

Il processo di fabbricazione mediante saldatura di strutture metalliche ed il suo controllo alla luce della EN 1090

LA NORMA EN Management of Hygiene in the. foodstuffs. Maurizio Bonuomo Barilla G. & R. Fratelli S.p.A. UNI - MILANO - 14 GENNAIO 2008

BS OHSAS 18001:2007 in ambito sanitario: l esperienza presso gli Istituti Clinici Zucchi

La flotta di Trenitalia (di cui. è ECM) proprietà): Famiglia Carri Carrozze Giorno Carrozze Notte ETR Loco da Treno

Att.: A tutti gli Organismi accreditati SGQ Ns. rif.: DC2016SPM143 Milano, 04/05/2016

Ingegneria del Software Testing. Corso di Ingegneria del Software Anno Accademico 2012/2013

USER LICENSE LICENZA D USO

REVISIONE DI ISO /IEC Lo stato dell arte

ISTRUZIONE OPERATIVA OPERATIVE INSTRUCTION

NUOVE E CONCRETE POTENZIALITA DI LAVORO NEL SETTORE ENERGETICO

DNV BUSINESS ASSURANCE

correzione, verifica e validazione dei risultati

ACCREDIA L ENTE ITALIANO DI ACCREDITAMENTO

CERTIFICATO N. EMS-1318/S CERTIFICATE No. FALPI S.R.L. RINA Services S.p.A. Via Corsica Genova Italy

Ingegneria del Software

Gli aspetti innovativi del Draft International Standard (DIS) ISO 9001:2015

CERTIFICATO N. CERTIFICATE No /06/S GESMAR GESTIONI MARITTIME S.P.A. ISO 9001:2015. RINA Services S.p.A. Via Corsica Genova Italy

CONVEGNO La Nuova Norma ISO 45001

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

I CAMBIAMENTI PROTOTESTO-METATESTO, UN MODELLO CON ESEMPI BASATI SULLA TRADUZIONE DELLA BIBBIA (ITALIAN EDITION) BY BRUNO OSIMO

ISTITUTO DI VIGILANZA DELL'URBE S.p.A.

La diagnosi energetica: un'opportunità per le imprese Daniele Forni, FIRE

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 SAN MARTINO SRL UNIPERSONALE

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07

Software. Engineering

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5

20x SSC Solution. For use in in situ hybridization procedures. For Research Use Only. Not for use in diagnostic procedures.

MED Certificato CE del Sistema di Garanzia della Qualità/ EC Quality Assurance System Certificate

1. Domanda di certificazione da riportare su carta intestata del fabbricante che richiede la certificazione / Certification request To report on

Circolare 1/2008 concernente il riconoscimento di standard di revisione (Circ. 1/2008)

Gestione dei Reclami e dei Ricorsi per la Certificazione Forestale e Catena di Custodia dei prodotti

TEST REPORT INDICE - INDEX

Studio I ng. Fab. rizio Di Crosta AGIRE 10/12/2008 1

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 PICCININ DANIELE - LE CARLINE

La serie di Norme ISO 10000


CERTIFICATO CE. Dichiarazione di approvazione del sistema qualità (Sistema completo di garanzia qualità) Certificato n. 1668/MDD HMC PREMEDICAL SPA

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07

Hyppo Swing gate opener

QUALIFICAZIONE DEI FORNITORI DI ECCIPIENTI E MATERIALI DI CONFEZIONAMENTO

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 CAPPELLETTI ENRICO- ARS NATURAE

Il controllo delle dichiarazioni di conformità. Valutazione delle principali non conformità

Il concetto di Processo nei modelli di eccellenza

CERTIFICATO DI CONFORMITA' Allegato a Documento giustificativo ai sensi dell'art. 29, 1 del Reg CE 834/07 EULAB SNC DI PECETTI & C.

UNICA nasce dal desiderio di vedere la sicurezza come valore nella vita di ognuno e come condizione necessaria per una realtà lavorativa sana e di

BUSINESS DEVELOPMENT MANAGEMENT

Testi del Syllabus. L insegnamento è composto dai seguenti moduli: ORGANIZZAZIONE AZIENDALE 7 CFU I FONDAMENTALI DI CONTROLLO DI GESTIONE 7 CFU

LINEE GUIDA PER IL "TAILORING DELLE NORME ECSS

CERTIFICATO CE DI CONFORMITÀ < PRODOTTO(I) (2) >

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY

COBIT. COBIT è un modello di riferimento che comprende una raccolta di best practice

CRESCE L ATTENZIONE AL RISK MANAGEMENT; ANCHE LA COMPETENZA?

Valori di riferimento e riferibilità delle misure nei requisiti di accreditamento ISO 15189

UNIVERSITÀ DEGLI STUDI DI TORINO

Pubblicazioni COBIT 5

Convegno Qualità Microbiologica dei Cosmetici: Aspetti Tecnici e Normativi Milano, 15 maggio Lucia Bonadonna Istituto Superiore di Sanità

Spett.le M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

OFFERTA DI LAVORO (1)

Riconciliazione tra istruzioni T2S ed istruzioni X-TRM

Transcript:

La nuova edizione della norma ISO 13485:2016 (UNI CEI EN ISO 13485:2016) Milano, 25 ottobre 2016 ing. Marco Magni Responsabile Certificazione Dispositivi Medici ITALCERT (O.N. 0426) (magni@italcert.it) 1

Non possiamo essere esaustivi Scopo delle seguenti slide e dell incontro è: dare le prime informazioni sulla norma dare i primi spunti di riflessione ed approfondimento invitarvialeggereerileggereiltestocercandodi farlo calare nella vs. realtà/organizzazione cercando di rivedere quello che già oggi fate (e magari gestite con routine) alla luce dei requisiti rimasti immutati e dei nuovi requisiti introdotti 2

1 Scope 2 Normative references 3 Terms and definitions 4 Quality management system 4.1 General requirements 4.2 Documentation requirements 4.2.1 General 4.2.2 Quality manual 4.2.3 Medical device file 4.2.4 Control of documents 4.2.5 Control of records 3

5 Management responsibility 5.1 Management commitment 5.2 Customer focus 5.3 Qualitypolicy 5.4 Planning 5.4.1 Quality objectives 5.4.2 Quality management system planning 5.5 Responsibility, authority and communication 5.5.1 Responsibility and authority 5.5.2 Management representative 5.5.3 Internal communication 5.6 Management review 5.6.1 General 5.6.2 Review input 5.6.3 Review output 4

6 Resource management 6.1 Provision of resources 6.2 Human resources 6.3 Infrastructure 6.4 Work environment and contamination control 6.4.1 Work environment 6.4.2 Contamination control 5

7 Product realization 7.1 Planning of product realization 7.2 Customer-related processes 7.2.1 Determination of requirements related to product 7.2.2 Review of requirements related to product 7.2.3 Communication 6

7.3 Design and development 7.3.1 General 7.3.2 Design and development planning 7.3.3 Design and development inputs 7.3.4 Design and development outputs 7.3.5 Design and development review 7.3.6 Design and development verification 7.3.7 Design and development validation 7.3.8 Design and development transfer 7.3.9 Control of design and development changes 7.3.10 Design and development files 7

7.4 Purchasing 7.4.1 Purchasing process 7.4.2 Purchasing information 7.4.3 Verification of purchased product 8

7.5 Production and service provision 7.5.1 Control of production and service provision 7.5.2 Cleanliness of product 7.5.3 Installation activities 7.5.4 Servicing activities 7.5.5 Particular requirements for sterile medical devices 7.5.6 Validation of processes for production and service provision 7.5.7 Particular requirements for validation of processes for sterilization and sterile barrier systems 7.5.8 Identification 7.5.9 Traceability 7.5.10 Customer property 7.5.11 Preservation of product 9

7.6 Control of monitoring and measuring equipment 10

8 Measurement, analysis and improvement 8.1 General 8.2 Monitoring and measurement 8.2.1 Feedback 8.2.2 Complaint handling 8.2.3 Reporting to regulatory authorities 8.2.4 Internal audit 8.2.5 Monitoring and measurement of processes 8.2.6 Monitoring and measurement of product 11

8.3 Control of nonconforming product 8.3.1 General 8.3.2 Actions in response to nonconforming product detected before delivery 8.3.3 Actions in response to nonconforming product detected after delivery 8.3.4 Rework 12

8.4 Analysis of data 8.5 Improvement 8.5.1 General 8.5.2 Corrective action 8.5.3 Preventive action 13

4.1.1 The organization shall document the role(s) undertaken by the organization under the applicable regulatory requirements. NOTE Roles undertaken by the organization can include manufacturer, authorized representative, importer or distributor. 14

4.1.2 The organization shall: a) determine the processes needed for the quality management system and the application of these processes throughout the organization taking into account the roles undertaken by the organization; b) apply a risk based approach to the control of the appropriate processes needed for the quality management system; c) determine the sequence and interaction of these processes. 15

-> maggiore enfasi circa approccio per processi basando tutto sulla gestione del rischio che tenga conto del ruolo che l organizzazione assume all interno del quadro regolatorio e del contesto in cui opera (ISO 9001) ma che tenga conto della gestione del rischio specifica del prodotto che si gestisce in qualità di fabbricante (ISO 14971) leggere bene in vari punti della norma 16

4.1.5 When the organization chooses to outsource any process that affects product conformity to requirements, it shall monitor and ensure control over such processes. The organization shall retain responsibility of conformity to this International Standard and to customer and applicable regulatory requirements for outsourced processes. The controls shall be proportionate to the risk involved and the ability of the external party to meet the requirements in accordance with 7.4. The controls shall include written quality agreements. 17

(nuova procedura documentata) 4.1.6 The organization shall document procedures for the validation of the application of computer software used in the quality management system. Such software applications shall be validated prior to initial use and, as appropriate, after changes to such software or its application. The specific approach and activities associated with software validation and revalidation shall be proportionate to the risk associated with the use of the software. Records of such activities shall be maintained (see 4.2.5). 18

4.2.2 Quality manual (nulla di nuovo) The organization shall document a quality manual that includes: a) the scope of the quality management system, including details of and justification for any exclusion or non-application; b) the documented procedures for the quality management system, or reference to them; c) a description of the interaction between the processes of the quality management system. The quality manual shall outline the structure of the documentation used in the quality management system. 19

4.2.3 Medical device file (ATTENZIONE!!!!) For each medical device type or medical device family, the organization shall establish and maintain one or more files either containing or referencing documents generated to demonstrate conformity to the requirement of this International Standard and compliance with applicable regulatory requirements. The content of the file(s) shall include, but is not limited to: a) general description of the medical device, intended use/purpose, and labelling, including any instructions for use; b) specifications for product; c) specifications or procedures for manufacturing, packaging, storage, handling and distribution; d) procedures for measuring and monitoring; e) as appropriate, requirements for installation; f) as appropriate, procedures for servicing. 20

RIESAME DIREZIONE 5.6.1 The organization shall document procedures for management review. (nuova procedura documentata) 21

Elementi in ingresso ed in uscita ampliati 5.6.2 The input to management review shall include, but is not limited to, information arising from: a) feedback; b) complaint handling; c) reporting to regulatory authorities; d) audits; e) monitoring and measurement of processes; f) monitoring and measurement of product; g) corrective action; h) preventive action; i) follow-up actions from previous management reviews; j) changes that could affect the quality management system; k) recommendations for improvement; l) applicable new or revised regulatory requirements. 22

5.6.3 The output from management review shall be recorded (see 4.2.5) and include the input reviewed and any decisions and actions related to: a) improvement needed to maintain the suitability, adequacy, and effectiveness of the quality management system and its processes; b) improvement of product related to customer requirements; c) changes needed to respond to applicable new or revised regulatory requirements; d) resource needs. 23

7.1 Planning of product realization The organization shall document one or more processes for risk management in product realization. Records of risk management activities shall be maintained (see 4.2.5). Note rif. ISO 14971 24

7.3.8 Design and development transfer (nuova procedura) The organization shall document procedures for transfer of design and development outputs to manufacturing. These procedures shall ensure that design and development outputs are verified as suitable for manufacturing before becoming final production specifications and that production capability can meet product requirements. Results and conclusions of the transfer shall be recorded (see 4.2.5). 25

7.3.9 Control of design and development changes (nuova procedura) The organization shall document procedures to control design and development changes. The organization shall determine the significance of the change to function, performance, usability, safety and applicable regulatory requirements for the medical device and its intended use. 26

7.3.10 Design and development files The organization shall maintain a design and development file for each medical device type or medical device family. This file shall include or reference records generated to demonstrate conformity to the requirements for design and development and records for design and development changes. 27

7.4.2 Purchasing information. Purchasing information shall include, as applicable, a written agreement that the supplier notify the organization of changes in the purchased product prior to implementation of any changes that affect the ability of the purchased product to meet specified purchase requirements. To the extent required for traceability given in 7.5.9, the organization shall maintain relevant purchasing information in the form of documents (see 4.2.4) and records(see 4.2.5). 28

7.5.6 The organization shall document procedures for validation of processes (già presente) (nuova procedura documentata) The organization shall document procedures for the validation of the application of computer software used in production and service provision. Such software applications shall be validated prior to initial use and, as appropriate, after changes to such software or its application. The specific approach and activities associated with software validation and revalidation shall be proportionate to the risk associated with the use of the software, including the effect on the ability of the product to conform to specifications. Records of the results and conclusion of validation and necessary actions from the validation shall be maintained (see 4.2.4 and 4.2.5). 29

7.5.7 Particular requirements for validation of processes for sterilization and sterile barrier systems The organization shall document procedures for the validation of processes for sterilization and sterile barrier systems. Processes for sterilization and sterile barrier systems shall be validated prior to implementation and following product or process changes, as appropriate Records of the results and, conclusion of validation and necessary actions from the validation shall be maintained (see 4.2.4 and 4.2.5). NOTE Further information can be found in ISO 11607-1 and ISO 11607-2. 30

7.6 Control of monitoring and measuring equipment The organization shall document procedures to ensure that monitoring and measurement can be carried out and are carried out in a manner that is consistent with the monitoring and measurement requirements. The organization shall perform calibration or verification in accordance with documented procedures. (nuova procedura documentata) 31

(nuova procedura) The organization shall document procedures for the validation of the application of computer software used for the monitoring and measurement of requirements. Such software applications shall be validated prior to initial use and, as appropriate, after changes to such software or its application. The specific approach and activities associated with software validation and revalidation shall be proportionate to the risk associated with the use of the software, including the effect on the ability of the product to conform to specifications. 32

8.2.1 Feedback The organization shall document procedures for the feedback process. This feedback process shall include provisions to gather data from production as well as post-production activities. The information gathered in the feedback process shall serve as potential input into risk management for monitoring and maintaining the product requirements as well as the product realization or improvement processes. 33

8.2.2 Complaint handling (nuova procedura) The organization shall document procedures for timely complaint handling in accordance with applicable regulatory requirements. 34

These procedures shall include at a minimum requirements and responsibilities for: a) receiving and recording information; b) evaluating information to determine if the feedback constitutes a complaint; c) investigating complaints; d) determining the need to report the information to the appropriate regulatory authorities; e) handling of complaint-related product; f) determining the need to initiate corrections or corrective actions. 35

If any complaint is not investigated, justification shall be documented. Any correction or corrective action resulting from the complaint handling process shall be documented. If an investigation determines activities outside the organization contributed to the complaint, relevant information shall be exchanged between the organization and the external party involved. 36

8.2.3 Reporting to regulatory authorities If applicable regulatory requirements require notification of complaints that meet specified reporting criteria of adverse events or issuance of advisory notices, the organization shall document procedures for providing notification to the appropriate regulatory authorities. 37

8.2.6 Monitoring and measurement of product (nuova procedura) The organization shall monitor and measure the characteristics of the product to verify that product requirements have been met. This shall be carried out at applicable stages of the product realization process in accordance with the planned and documented arrangements and documented procedures. 38

8.3 control of nonconforming product 8.3.1 General The organization shall ensure that product which does not conform to product requirements is identified and controlled to prevent its unintended use or delivery. The organization shall document a procedureto define the controls and related responsibilities and authorities for the identification, documentation, segregation, evaluation and disposition of nonconforming product. 39

8.3.2 Actions in response to nonconforming product detected before delivery The organization shall deal with nonconforming product by one or more of the following ways: a) taking action to eliminate the detected nonconformity; b) taking action to preclude its original intended use or application; c) authorizing its use, release or acceptance under concession. The organization shall ensure that nonconforming product is accepted by concession only if the justification is provided, approval is obtained and applicable regulatory requirements are met. Records of the acceptance by concession and the identity of the person authorizing the concession shall be maintained(see 4.2.5). 40

8.3.3 Actions in response to nonconforming product detected after delivery When nonconforming product is detected after delivery or use has started, the organization shall take action appropriate to the effects, or potential effects, of the nonconformity. Records of actions taken shall be maintained (see 4.2.5). The organization shall document procedures for issuing advisory notices in accordance with applicable regulatory requirements.these procedures shall be capable of being put into effect at any time. Records of actions relating to the issuance of advisory notices shall be maintained (see 4.2.5). 41

8.3.4 Rework(nuova procedura) The organization shall perform rework in accordance with documented procedures that takes into account the potential adverse effect of the rework on the product. These procedures shall undergo the same review and approval as the original procedure. After the completion of rework, product shall be verified to ensure that it meets applicable acceptance criteria and regulatory requirements. Records of rework shall be maintained (see 4.2.5). 42

8.4 Analisi dei dati(procedura documenta) 8.5.2 Azioni correttive(procedura documenta) 8.5.3 Azioni preventive (procedura documenta) 43

E SE ARRIVA ANCHE NUOVO REGOLAMENTO UE DISPOSITIVI MEDICI che sostituisce la direttiva 93/42/CEE????? 44

PRESENTE Reg. 920/2013 + Raccomandazione 2013/473/UE - Maggiori registrazioni/evidenze per gli ON - Molta attenzione sui dati clinici / dati pre-clinici TEMPI PIU CONSISTENTI per tutti Il fabbricante deve avere un proprio specifico fascicolo tecnico (non esiste più concetto di OWN BRAND LABELLING come è stato finora accettato) 45

FUTURO Primi mesi del 2017? Testo finale in traduzione per arrivare pubblicazione dopo 20g entra in vigore ma con tempi diversi di applicazione dei vari capi Nuove regole di classificazione Nuove procedure di certificazione (scrutiny?) Maggiori oneri per fabbricante in termini di risorse e documentazione (UDI / EUDAMED ). Ne parleremo al prossimo seminario. 46

ISO 13485:2016 (UNI CEI EN ISO 13485:2016) Regole per il passaggio delle certificazioni Milano, 25 ottobre 2016 ing. Marco Magni Responsabile Certificazione Dispositivi Medici ITALCERT (O.N. 0426) (magni@italcert.it) 1

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 La norma ISO 13485:2016 Medical devices Quality management systems - Requirements for regulatory purposes è stata pubblicata in data 01 marzo 2016 Ad oggi è stata recepita all interno della normazione europea/italiana -> UNI CEI EN ISO 13485:2016 ma non è ancora disponibile in lingua italiana 2

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Per tutti i 3 anni successivi alla data di pubblicazione della norma ISO 13485:2016, saranno valide sia le certificazioni emesse a fronte della ISO 13485:2003, sia le certificazioni emesse a fronte della ISO 13485:2016. Solo dopo 3 anni dalla pubblicazione della ISO 13485:2016, le certificazioni accreditate emesse a fronte delle ISO 13485:2003 non saranno più valide e dovranno essere revocate. La data di scadenza delle certificazioni ISO 13485:2003 emesse durante il periodo di transizione dovrà corrispondere alla fine del periodo di transizione di tre anni. 3

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 TERMINE TRANSITORIO 28 febbraio 2019 4

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 In accordo alle norma di accreditamento per gestire la transizione tra ISO 13485:2003 e ISO 13485:2016 delle certificazioni, l'organismo di Certificazione deve effettuare un audit presso ogni cliente, a fronte della nuova norma ISO 13485:2016(ricertificazione) 5

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 In generale ITALCERT prevede di gestire la transizione mediante tale audit di ricertificazione coincidente con il rinnovo programmato. 6

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Se la transizione viene richiesta in occasione di un rinnovo, ITALCERT prevede di calcolare i gg/u necessari utilizzando le normali tabelle internazionali(iaf MD5/ IAF MD09) previste perilcalcolodeigg/u 7

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Viene lasciata anche la possibilità di effettuare la transizione alla nuova norma mediante un audit di sorveglianza programmata con durata maggiorata e con relativi costi aggiuntivi da quantificare Si ricorda che in caso di richiesta di passaggio alla ISO 13485:2016 in occasione di un audit di sorveglianza la richiesta dovrà essere fatta almeno due mesi prima dell audit (per poter organizzare dal punto di vista logistico l incremento di durata dell audit e valutare i relativi costi e fare le opportune comunicazioni all organizzazione certificata) 8

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Se non risultasse possibile effettuare l audit di passaggio prima della scadenza del transitorio, il certificato cesserà di valere. Tuttavia è stata prevista una finestra di 6 mesi per consentire all Organizzazione di richiedere il ripristino della certificazione. Essa avverrà mediante un audit di durata intermedia tra una nuova certificazione e un rinnovo. La scadenza sarà pari a 3 anni dalla fine del transitorio. 9

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 L Organismo di Certificazione, prima di rilasciare certificati a fronte della ISO 13485:2016, deve ottenere l aggiornamento del proprio accreditamento. La valutazione di ACCREDIA avviene su base documentale. (audit in sede ITALCERT previsto 09-10-11 novembre 2016) ITALCERT prevede di ottenere l aggiornamento dell accreditamento nel mese di dicembre 2016 / gennaio 2017(in dipendenza dalle date disponibili dei Comitati di ACCREDIA) 10

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Criticità passaggio ISO 9001:2015 - ISO 13485:2016 Là dove possibile raccomandiamo di condurre comunque passaggio congiunto ricordando che comunque i requisiti ISO 13485 (specie se legati direttiva 93/42/CEE) sono di fatto COGENTI Eventuali situazioni particolari verranno valutate caso per caso ricordiamo termine transitorio ISO 9001:2015 è 14 settembre 2018 11

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Criticità passaggio ISO 9001:2015 - ISO 13485:2016 Differenza tra HIGH LEVEL STRUCTURE ISO 9001:2015(10 punti norma) e vecchia struttura ISO13485:2016(8 punti norma ma con punti norma nuovi e/o revisionati rispetto alla edizione 2003) 12

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Criticità passaggio ISO 9001:2015 - ISO 13485:2016 In riferimento al fatto che la nuova ISO 9001:2015 non prevede obbligatoriamente un MANUALE QUALITA le aziende che hanno un sistema ISO 13485:2016 debbono invece obbligatoriamente mantenere un MQ correlato a tale norma. Potrebbe essere accettabile: - Mantenere un manuale solo ISO 13485 e gestire le ulteriori informazioni documentate in riferimento diretto alla ISO 9001 - Creare un manuale integrato ISO 13485 + ISO 9001, che potrebbe seguire l indice di una delle due norme(meglio della ISO 13485) e contenere una tabella di correlazione per l altra norma. -Creareduemanuali(ISO13485eISO9001) 13

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 Criticità passaggio ISO 9001:2015 - ISO 13485:2016 IMPORTANTE LA COMPRENSIONE E L UTILIZZO DI: -ANNEX A ISO 13485:2016 (comparison of content between ISO 13485:2003 and ISO 13485:2016) ANNEX B ISO 13485:2016 (correspondence between ISO 13485:2016 and ISO 9001:2015) eventuale consiglio è di dotarsi di tabelle/checklist per esplicitare dove ed in che modo vengono soddisfatti gli specifici requisiti all interno del sistema di gestione. 14

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 per gestire la verifica della conformità ai requisiti della nuova edizione della norma verrà reso disponibile prima dell audit alle organizzazioni QV DOCUMENTALE (per passaggio a edizione norma 2016 e per stage 1 nuove certificazioni ISO 13485:2016) da compilare a cura dell organizzazione e rendere disponibile al GVI all inizio dell audit Sarà oggetto di verifica puntuale nel corso dell audit 15

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 APPROCCIO AGLI AUDIT Per chi mantiene la certificazione ISO 9001 IlpercorsodipassaggiotraISO9001:2008eISO9001:2015nonè e non dovrebbe essere solo una diversa modulazione di requisiti, ma l evoluzione di un differente modo di guidare l organizzazione. Anche per questo diventa necessario un approccio per gradi da parte dell ente di certificazione. Per gli auditor rimangono valide tutte le istruzioni/indicazioni fornite per la transizione alla norma ISO 9001:2015 19

TRANSIZIONE ISO 13485:2003 - ISO 13485:2016 RICORDIAMOCI però che rimane valido ed anche rafforzato lo scopo della norma ISO 13485:2016 Medical devices Quality management systems -Requirements for regulatory purposes -> dimostrare la conformità 20