QUADRO BLINDATO ISOLATO IN SF6 PER RETI SECONDARIE SF6 INSULATED METAL-CLAD RING MAIN UNIT FOR DISTRIBUTION NETWORKS

Documenti analoghi
QUADRI J QUADRI ELETTRICI DI MEDIA E BASSA TENSIONE QUADRI J MEDIUM AND LOW VOLTAGE SWITCHBOARDS. 50a. jolly set

Apparecchiature di media tensione isolate in gas Gas-insulated medium voltage equipments. Serie G

PROVE ACCREDITATE - CATEGORIA: 0

INTERRUTTORE SWITCH-DISCONNECTOR TH 12kV - 400A-630A. INTERRUTTORE SWITCH-DISCONNECTOR TH 17kV - 400A-630A CHIUSO CLOSED CHIUSO CLOSED APERTO OPEN

Quadri di media tensione con IMS isolati in gas - Classe LSC2A-PM Medium voltage metal enclosed switchboards with SF6 insulated LBS MINIBLOC - 636

Quadro protetto di Media Tensione Metal-enclosed protected switchboard. AirMET 36 kv. CATALOGO GENERALE General catalogue

QUADRI J QUADRI ELETTRICI DI MEDIA E BASSA TENSIONE QUADRI J MEDIUM AND LOW VOLTAGE SWITCHBOARDS. 50b. jolly set

sezionatori a cerniera disconnectors interruttori di manovra - sezionatori load break switches

SEZIONE 2 SEZIONATORI

Energy Transmission & Distribution Services - Italia

Sezione 2 SEZIONATORI

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

Valvole / Valves 36 68

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

Medium voltage products UniSec SBC-W Quadro di media tensione isolato in aria per la distribuzione secondaria

norme BS 88 BS 88 standards fusibili e portafusibili norme bs 88 FuSeS and FuSeHolDeRS

pressostati pressure switches

IMM Drukmat voor het beveiligen van gevaarlijke zones rondom machines. Indien men op de mat staat schakelt de mat de noodstop in.

Serie 0135 Multipolari. Sezionatori serie compatta multipolari. Disconnecting switches multipole series - compact

Guida alle caratteristiche generali General specifications COMANDO / CONTROL SICUREZZA / SAFETY ISOLATED ISOLAMENTO / ISOLATED

GEMINI. il nuovo operatore compatto e leggero. the new compact and light door operator

MANUALE NEON - NEON HANDBOOK European Standard (I.C.C. 1,3)

POWER PROJ. LAMP. Traversing table height: 910 mm. (36") Maximum height: 2100 mm. (82") Fluorescent lamp: 15 W. Chair mod. 88HE

Soluzioni per l energia solare Solutions for solar energy

ELERON. SPE 485 Sezionatore per esterno MT isolato in aria

GENERATORE-SALDATRICE WELDING-GENERATOR

Serie MEGA. Quadri mobili stagni di grossa potenza da cantiere secondo la norma EN

RPS TL System. Soluzioni per l energia solare Solutions for solar energy

Trasformatori e Alimentatori Transformers and power supplies. ASSA ABLOY, the global leader in door opening solutions

FUSE MODULES DIODE MODULES

controlli di livello capacitivi capacitive levels controls

SINTER MV combined circuit breaker with switch and vacuum breaker, for medium voltage switchboards, with arcing proof.

AUTOMAZIONI PER PORTE BATTENTI

Medium voltage products UniSec per impianti solari Quadro di media tensione isolato in aria per la distribuzione secondaria

Serie 0135 Multipolari. Sezionatori serie compatta multipolari. Disconnecting switches multipole series - compact

SRE 243 Sezionatore tripolare a rotazione per esterno

BUILDING FEATURES ISO / CARATTERISTICHE COSTRUTTIVE VALVOLE ISO 24563

TRASFORMATORI DI CORRENTE PER BASSA TENSIONE

Serie DS. Interruttori di manovra-sezionatori NOVITÀ.

Scaricatori e limitatori di sovratensione

Sezionatori e Interruttori di manovra-sezionatori a cerniera Load break switches and Disconnectors

24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC 24V AC/DC V AC V AC V AC V AC V AC V AC

Evoluzione della forma Evolution of the shape

Distributore Dosatore GPL&Metano serie JMU JMU serie : LPG and NGV Gas Dosage Unit

% x 2800 m m = 18% 100 m. 100 m

SIMONAZZI F.LLI S.r.l. - S. ILARIO D ENZA (RE) ITALY - Tel Fax

- circuiti ausiliari e di potenza in assenza di tensione. - molle di comando interruttore scariche. - interruttore aperto e sezionato

quadri protetti di media tensione di dimensioni compatte medium voltage metal enclosed compact dimensions switchboards

SPINTA TRAZIONE THRUST TENSILE CORSA STROKE

Evoluzione della forma Evolution of the shape

SISTEMA DI ILLUMINAZIONE PER VERRICELLI WINDLASS LIGHTING SYSTEM

Quality Reliability Flexibility. Trasformatori di potenza in olio Oil Transformers

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

COMMUTAZIONE AUTOMATICA E la funzione che governa la commutazione tra due linee in un tempo regolabile fra 0,5 e 120 secondi.

quadri protetti di media tensione di dimensioni compatte medium voltage metal enclosed compact dimensions switchboards

CHARACTERISTICS AND APPLICATIONS

Lwa 95 (70db a 7m) omologazione "direttiva 2000/14/CE"

Compressori a vite CXHO Schemi elettrici CXHO screw compressors Wiring diagrams. PWS start Legenda. Legenda avviamento PWS V3 V2 V1

Interruttore di manovra sezionatore MT Isolato in aria installazione per esterno. Tipo V0 380

DESCRIPTION DESCRIZIONE CARATTERISTICHE FEATURES

5-1 INDICE CONTATTORI MODULARI CONTENTS INSTALLATIONS CONTACTORS. Prodotti pag. 6-2 Products

DAISY-OUT SERIES DAISY-OUT

OT160G Interruttori di manovra sezionatori Design semplice e intelligente che porta al risparmio

CILINDRI ROTANTI ROTARY CYLINDERS

Naturalmente Energia.

Addolcitori Softeners

Interruttori di manovra sezionatori A. Switch disconnectors 55GTGLOBE TECHNICS

sensori per cilindri magnetic sensors for cylinders Schema di collegamento: 2 fili Wiring diagram: 2 wires RS2-A RS1-A RS3-A RS4-A RS5-C Modello Model

INTERRUTTORI SALVAMOTORI MAGNETOTERMICI

TMsec. Quadro di media tensione per distribuzione secondaria isolato in aria. Air-insulated medium voltage switchgear for secondary distribution

Tubazioni elettriche metalliche non filettate tipo EMT Unthreaded Electrical Metallic Tubing Type EMT Unthreaded Thin-Wall Raceway

Scaricatori MT ABB Trento 30/11/2012. Scaricatori ABB. Insert product picture here. Benefici e vantaggi. Insert product symbol here

Trasformatori scatolati e convertitori Plastic box current transformers and transducers. Edizione dic 09 Ediction dec 09

Meterage chart. Tabelle metriche. Solo per serie GREENLine. Only for GREENLine series

INTERRUTTORI DI SICUREZZA A FUNE PULL WIRE SAFETY SWITCHES

» K IN L A S R E V 16

PROGETTO DI INTERVENTO DI RETROFIT PARZIALE DELLA SOTTOSTAZIONE ELETTRICA AT / MT A 132 KV SPECIFICHE TECNICHE APPARECCHIATURE ALTA TENSIONE

OIL IMMERSED TRANSFORMERS TRASFORMATORI IN OLIO. Isolationclassup to 24 kv. Classe di isolamento fino a 24 kv. Caratteristiche generali

SDS Surge Defence System

VALVOLE DI INVERSIONE DI CICLO REVERSING VALVES UMKEHRVENTILE

I INSERZIONE DI CONDENSATORI TRIFASI PER IL RIFASAMENTO MEDIANTE CONTATTORI

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/ Fax 057/ internet:

/ < " DI MANAGEMENT C RTI ICA ISTEM )3/ )3/ ä - "

STAND ALONE LED PV KIT WITH ROAD ARMOR

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

Inverter ibridi trifase x-hybrid serie T

Addolcitori Softeners

CURVATURA - BENDING C50 ES

FUSIBILI E BASI MEDIA TENSIONE SERIE FMT MEDIUM VOLTAGE FUSES AND FUSE BASES, SERIES FMT

EWC GROUP srl QUADRI SPECIALI DI COMANDO E CONTROLLO COMMAND AND CONTROL SPECIAL PANELS

MANUALE D USO PER TRASFORMATORI DI CORRENTE PER MISURA IN MEDIA TENSIONE

PRODOTTI RULLI CILINDRICI RULLINI CILINDRICI SPINE CILINDRICHE ALBERINI CILINDRICI

Interruttori di manovra-sezionatori

Quadri Blindati di media tensione isolati in aria categoria LSC2B - PM Air insulated medium voltage Metal Clad Switchboards LSC2B - PM category

MOTORI C.C. D.C. MOTORS

Areti SpA. Direzione Operazioni

SPECIFICA TECNICA - TECHNICAL SPEC. Alimentatore DC MINI JOLLY LC DALI Dimmable LED AC/DC Power Supply INPUT

MV SF6 insulated Ring Main Unit Quadro RMU in media tensione isolato in SF6 VEGA

NORME E GUIDE TECNICHE PROGRAMMA DI LAVORO PER INCHIESTE PRELIMINARI TECHNICAL STANDARDS AND GUIDES PROGRAMME OF WORKS FOR PRELIMINAR ENQUIRY

Distribuzione di corrente

Transcript:

INDOOR MCSG-RMU-GIC UP TO 24kV-630A-25kA QUADRO BLINDATO ISOLATO IN SF6 PER RETI SECONDARIE SF6 INSULATED METAL-CLAD RING MAIN UNIT FOR DISTRIBUTION NETWORKS

CARATTERISTICHE TECNICHE Le cabine blindate tipo MCSG-RMU-GIC a media tensione sono isolate in SF6 alla pressione di 125 KPa a 20 C sono realizzate in un unico quadro compatto a tenuta stagna con chiusure laterali imbullonate. La composizione standard del quadro prevede due arrive linea ed una partenza trasformatore; l elemento base è costituito da un interruttore di manovrasezionatore a tre posizioni (chiuso, sezionato, a terra) azionato da un unico comando montato direttamnte sul fronte del quadro. La camera di interruzione, brevettata e di concezione avveniristica, consente una notevole riduzione della produzione di residui carbonosi dovuti alla decomposizione dell SF6 durante l arco elettrico e di conseguenza una maggiore durata elettrica. I contenitori dei fusibili, costruiti in resina epossidica, sono montati frontalmente in un cassetto posto al di fuori del contenitore blindato. La messa a terra dei fusibili, a monte ed a valle, viene realizzata aggiungendo all interruttore di manovra-sezionatore un contatto sulla parte mobile (vedi fig. 1). I comandi semplici e funzionali sono garantiti per oltre 5000 manovre meccaniche; sono provvisti di blocchi ad impedimento che li rendono estremamente sicuri. Vengono montati già predisposti per il comando a distanza applicabile in qualsiasi momento. Il quadro è conforme alle norme IEC 694, 298, 265, 420, 129, 56. TECHNICAL CHARACTERISTICS The Metal-Clad MCSG-RMU-GIC type M.V Ring- Main-Unit is fully insulated in SF6 at the pressure of 125 KPa at 20 C. it is realized in a compact selfsupporting metal-clad structure having a bolted gastight opening on the sides. The standardized scheme of R.M.U includes two incoming line and one transformer outlet ; the main and basic component in the 3 position L.B. switch (Close, Open, Earth) operated by means of a control mechanism fitted on the front of R.M.U itself. The patented and forthcoming breaking chamber allows a wide and big reduction of carbonium oxide components due to the chemical reaction of SF6 during the arcing time and consequently a longer electrical life. The epoxy resin fuse containers are located on a front drawer outside outside the metal-clad container. The fuse grounding; up and down stream, is obtained by means of an additional moving contact of the L.B. switch (see Pic.1). The operating mechanism are very simple, reliable and also they are guaranteed for more than 5000 cycles C- O-E; they are complete with necessary and required interlockes for preventing wrong operation and giving extreme security and reliability. They are already provided for the remote control, applicable anytime upon request. The R.M.U is complying to IEC 694, 298, 265, 420, 129, 56. Standards. Fig.1 CHIUSO CLOSED APERTO OPEN A TERRA EARTHED 2

CARATTERISTICHE TECNICHE TECHNICAL CHARACTERISTICS Tensione nominale Rated voltage Tensione nominale di tenuta ad impulso atmosferico Lightning impulse test voltage Tensione nominale di tenuta a 50 Hz per 1 min Power frequency apply voltage for 1 min kv 12 15-17.5 24 kv 75 95 125 kv 28 38 50 Arrivo linea Incoming line Corrente nominale Rated current A 400 630 400 630 400 630 Corrente breve durata nominale per 1 Sec. Rated short time current for 1 Sec. ka 16 25 16 25 16 25 Potere di chiusura nominale su corto circuito dell IMS e del ST Rated making current on line switch and earthing switch ka 40 62,5 40 62,5 40 50 Partenza trasformatore Transformer outlet Corrente nominale Rated current A 200 200 200 Potere di chiusura nominale su corto circuito dell IMS (1) Rated making current on main switch (1) ka 62.5 62.5 50 Potere di chiusura nominale su corto circuito del sezionatore di terra Rated making current on earthing switch ka 10 10 10 (1) Valore presutno, la corrente è di fatto limitata dai fusibili (1) Presumed, value, the current is limited by the fuses 3

Tabella per la scelta dei fusibili di protezione dei trasformatori Table for selection of transformers protection fuses Tensione nominale Rated voltage kv Potere di interruzione Breaking capacity ka Lunghezza max Maximum lenght mm Diametro min/max Diameter min/max mm 12 > 16 358 +4-1 50/80 17.5 > 16 433 +4-1 50/80 24 > 16 508 +4-1 50/80 4

Dimensione d ingombro MCSG-RMU-GIC 12-15/17,5-24 kv Overall dimension MCSG-RMU-GIC 12-15/17,5-24 kv EWC GROUP srl (25082) Botticino via G. Pastore, 36 (BS)- Email: thaer@ewcgroup.it Website: www.ewcgroup.it - Mobile: +39 392 678 5050 / Tel.&Fax: +39 030 2692486. 5

CONTACT US EWC GROUP srl ( ITALY - BOTTICINO) Via Giulio Pastore, 36 (25082) Botticino (BS) - Italy Tel.&Fax: +39 0302692486 Mobile: +39 3398887519 Email: thaer@ewcgroup.it Website: www.ewcgroup.it 6