ADDOLCITORI AUTOMATICI



Похожие документы
lambro ADDOLCITORI AUTOMATICI AUTOMATIC SOFTENERS Divisione Idrodepurazione srl A TEMPO E VOLUMETRICI PER PORTATE DA 1 A 45 m 3 /h

Addolcitori Softeners

Addolcitori Softeners

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION

addolcitori senza alimentazione elettrica

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

OSI I INDUSTR T IAL A E

ENVIRONMENTAL CONTROL & LEAK DETECTION SYSTEM

Addolcitori Softeners

ENVIRONMENTAL CONTROL & LEAK DETECTION SYSTEM

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

POMPA A MANO MODULARE DI EMERGENZA

Freni idraulici multidisco serie F Hydraulic Multidisc Brakes F Series

DEVIATORI DI FLUSSO DIVERTER VALVES

TORRINO DI ESTRAZIONE AD ALTO RENDIMENTO

Addolcitori Serie Pura S

SERIE APM-110 BAR SERIES. Filtri in linea a media pressione In line filter medium pressure. Filtri - Filters 09

V PLUS. bollitore verticale in acciaio vetrificato LE NUOVE ENERGIE PER IL CLIMA

Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no.

ENVIRONMENTAL CONTROL & LEAK DETECTION SYSTEM

Acqua dolce per la vita!

filtro separatore G1 G1 filter-water-separator

apparecchitechno TECHNOappliances

MANUALE D USO POMPA NEBULIZZATRICE PER RISPARMIO ENERGETICO RW MINI PER IMPIANTI RESIDENZIALI

Column version with channel profile arm A colonna con braccio in profilato a canalina 162

VALVOLE DI MASSIMA PRESSIONE RELIEF VALVES

FILTRI RAPIDI IN PRESSIONE PRESSURE FILTERS

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/ Fax 057/ internet:

Generatori ad inverter ed elettronici per saldatura MMA e TIG lift

P826-5 P P P P P P P P : 5 1: 10 1: 20 1: 42 1: 65 1: : : : 345

ENERGY-EFFICIENT HOME VENTILATION SYSTEMS

Macchine ad Impatto Impact machines

- nice to meet you. -

TLR05S-350. Extender in corrente costante, 3 x 350mA per TLR04M_

Attuatore a relè Manuale di istruzioni

Recuperatori di calore

filtro separatore G1/4 G1/4 filter-water-separator

Attuatore a relè Manuale di istruzioni

Chiudiporta nascosto a camma 900 Concealed cam door closer 900. ASSA ABLOY, the global leader in door opening solutions

Il nuovo modello FLUENDO AVENIR OUTDOOR

Generalità sulle elettropompe

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

pressostati pressure switches

CALCOLO DI UN IMPIANTO DI ADDOLCIMENTO A SCAMBIO IONICO AL SERVIZIO DI UN COMPLESSO ALBERGHIERO

E-VAG. VASCHE DI ACCUMULO GHIACCIO ad espansione diretta di refrigerante

IL TRATTAMENTO DELL'ACQUA NEGLI IMPIANTI DI RISCALDAMENTO ACQUA SURRISCALDATA (<180 C) ED A VAPORE BASSA PRESSIONE (< 100 kpa)

alte prestazioni allo specchio luxury luxury

Condizionatori per Cabinet

Con Clean aria pulita da polveri: Mod. CAP

Your home comfort has a new shape. Find out how it works

3 Valvole DE - Acqua a 40 bar 3 D.A. Valve for water at 40 bar

lux 18_25 alluminio anodizzato

MASAJA - MASAJA INOX DESCRIZIONE PER CAPITOLATO DIMENSIONI MASAJA / MASAJA INOX

ANODIZING EXCHANGE UNIT AND TEMPERATURE CONTROL

TORCIA CHIUSA PER BIOGAS tipo TBE. ENCLOSED BIOGAS FLARE TBE Type DESCRIZIONE DESCRIPTION VANTAGGI

KEEP IT DRY. Il nuovo simbolo per il risparmio energetico

NEWS 68. Valves and Solenoid valves Poppet system N776 Series

ELETTROPOMPE CENTRIFUGHE MONOBLOCCO

GAB. Scheda Tecnica Data Sheet. Caldaie Termostufe Termocamini Stufe Design, Quality & Production Made in Italy

No pump group / 1 pump group. 0, m3/h 1206A 1306A 1506A 1802A-2002A-2202A-2502A 2802A-3002A pump group for 1206A-1802A

Nome o marchio del fornitore. Numero articolo X X KIT2616 Power Unit, Quadro di parallelo iq10, Heat distributor Q20

ARCHITETTURA DEL SISTEMA

VALVOLE DI SFIATO ARIA AUTOMATICHE AUTOMATIC AIR VENT VALMAT VALMAT AUTOMATIC AIR VENT VALMAT VALVOLE DI SFIATO ARIA AUTOMATICHE VALMAT

Futura Soluzione per il Riscaldamento Domestico. Da aria in acqua

TABELLA DI IDENTIFICAZIONE CODICI POMPE HWD A 1515 B 1818 A B 2121 A B 2525 A B 1821 A B

SICOM FOR NATURAL GAS FILLING STATIONS TECNOLOGIA CNG

Cultura generale. per tutti i produttori di ghiaccio. Qualità dell acqua / qualità del ghiaccio.

Fustella Rotativa RD-4055 RD Fustella Rotativa. Sistema di fustellatura semplice, compatto e dall elevato standard qualitativo

LA SOLUZIONE PER I VOSTRI PROBLEMI

Design, Quality & Production Made in Italy GENERATORI D ARIA. Scheda Tecnica Data Sheet. Caldaie Termostufe Termocamini Stufe

Soluzioni per il risparmio idrico per i WC

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

DOVE SI APPLICA. Si applica sia all edilizia pubblica che a quella privata, anche nel caso di ristrutturazioni di edifici esistenti.

Ozono per la disinfezione e l ossidazione con ProMinent Produrre e dosare ozono in pieno rispetto dell ambiente

La tecnologia di nuova generazione per il trattamento delle acque di pozzo e di superficie

DISSUASORE FAAC J200 F DESCRIZIONE DI CAPITOLATO

BILANCIAMENTO / BALANCING

Addolcitore d acqua KaltecSoft. Da un acqua calcarea un acqua leggera come una piuma

ACCESSORI INDICATORI DI LIVELLO A VETRO

PRODUTTORI ACs. Li-Wu Perito termotecnico. sbk. scambiatore di calore a piastre. L evoluzione del sapere.

Diffusori ad alta induzione a geometria variabile High induction diffuser variable geometry

Modifiche costruttive e sostituzione di una macchina facente parte di un insieme complesso

Cannone abbattimento polveri e odori Silenziato e Autonomo

controlli di livello capacitivi capacitive levels controls

IMPIANTO MODULARE PER IL CONTROLLO DI PROCESSO. Mod. CPMS/EV

ENERBOX ENERBOX. SEGNALAZIONI Grazie al GSM integrato, in caso di black-out od anomalie, Enerbox invia

SCALDABAGNI ISTANTANEI A GAS

componenti per Magazzini dinamici components for Material handling

generatori di vuoto multistadio e multifunzione SERIE mvg

Un valore trasparente

Транскрипт:

A tempo e volumetrici per portate da 1 a 45 m³/h Timer and meter control softeners for flows from 1 to 45 m³/h

PRINCIPI DI FUNZIONAMENTO Gli addolcitori trovano applicazione in quei circuiti ove è indispensabile eliminare i sali incrostanti di calcio e magnesio. Le resine sintetiche con cui è caricato l addolcitore consentono la sostituzione nell acqua dei sali di calcio e magnesio con sali di sodio solubili. L efficienza delle resine viene ripristinata, in modo del tutto automatico, mediante passaggio di salamoia satura preparata nell apposita vasca del sale fornita a corredo dell apparecchiatura. La scelta dell addolcitore è funzione di: Portata ciclica, pari alla quantità d acqua avente durezza convenzionale di 1 F che può essere addolcita tra due rigenerazioni (la portata ciclica va divisa per i gradi francesi dell acqua da trattare per sapere la quantità prodotta tra due rigenerazioni). Portata oraria richiesta dall utilizzo. TIPI DI FUNZIONAMENTO E APPLICAZIONI Funzionamento automatico a tempo: e il classico sistema che trova applicazione nelle abitazioni civili e laddove la produzione richiesta è abbastanza costante (disponendo di fermi per la rigenerazione). Funzionamento automatico volumetrico: si applica quando la produzione richiesta è di carattere discontinuo (es. reintegro di circuiti), oppure se esiste la possibilità di disporre di un opportuno serbatoio di stoccaggio acqua addolcita. Il vantaggio consiste nel fatto che il consumo di sale è direttamente proporzionale alla produzione di acqua addolcita. Funzionamento automatico volumetrico duplex alternato: si applica quando è richiesta una produzione continua di acqua addolcita, 24 ore su 24. Il vantaggio consiste nel fatto che il consumo di sale è direttamente proporzionale alla produzione di acqua addolcita e che la produzione può avvenire senza interruzioni. OPERATING PRINCIPLES The softeners are used in those circuits where it is necessary to eliminate incrusting calcium and magnesium salts. The synthetic resins, the softener is fed with, allow the substitution in the water of the calcium and magnesium salts with soluble sodium salts. The efficiency of the resins is automatically recovered by the flowing of saturated brine prepared in a special salt tank supplied with the plant. The choice of the softener depends on: Cyclical flow, equal to the amount of water with the conventional hardness of 1 F that can be softened between two regenerations (the cyclic flow is to be divided by the French degrees of the water to be treated to know the amount of water produced between the two regenerations). Hourly flow required for utilization. FUNCTIONING TYPES AND APPLICATIONS Automatic time control functioning: is the classic system that find application in households and with a relatively costant water demand (needing set up time for regeneration). Automatic volume control functioning: it finds application with discontinuos flow (e.g. refilling boiler), or if exist the storage tank for softener water. The advantage is that the salt consumption is directly proportional to the softener water production. Automatic volume control alternate duplex functioning: it finds application when a continuos production of softener water is required, 24 hours a day. The advantage is that the salt consumption is directly proportional to the softener water production and flow is continuous. MODELLI STANDARD Il comando automatico d inizio rigenerazione può essere: A tempo: addolcitori HL/n e D Volumetrico: addolcitori HLW/n e DW Duplex: addolcitori HLWX/n e DWX STANDARD MODELS The automatic control for starting regeneration can be: Timer control: HL/n and D softeners Volume control: HLW/n and DW softeners Duplex: HLWX/n and DWX softeners 1

ADDOLCITORI HL/n I componenti standard sono: Bombola in vetroresina rinforzata, completa di distributori e resina scambiatrice di grado alimentare. Valvola automatica monoblocco, completa di programmatore e dispositivi per il corretto funzionamento. Serbatoio di preparazione e stoccaggio salamoia. Filtro dissabbiatore (optional). Se ne consiglia l installazione per evitare che corpi solidi presenti nell acqua possano compromettere il funzionamento dell impianto. SOFTENERS HL/n The standard components are: Reinforced fiberglass cylinder, complete with dispensers and food-grade ion exchange resin. Automatic monoblok-valve, complete with programming unit and devices for its functioning. Brine preparation and strorage tank Sand-catching filter (optional). Its installation is recommended to prevent solid matter in the water from compromising the plant functioning. ADDOLCITORE HL/n SOFTENERS HL/n ADDOLCITORE DUPLEX HLWX/n DUPLEX SOFTENERS HLWX/n Tipo Attacchi Volume Portata Perdita Portata ciclica e consumo Capacità Altezza Ingombro in pianta resina massima di carico sale per rigener. vasca sale totale (con serbatoio) Model Connect. Resin volume Maximum ow Pressure drop Cyclic ow and salt consump on per regener. Brine tank Total Height Plan dimensions (with tank) HL/n Media/Medium Massima/Maximum I m³/h kpa m³. F Kg m³. F Kg I mm mm 10 1" 10 1 60 50 1,2 70 2,4 85 650 660x400 15 1" 15 1,5 60 75 1,8 105 3,6 85 1100 660x400 20 1" 20 2 70 100 2,4 140 4,8 85 1100 660x400 25 1" 25 2,5 70 125 3,0 175 6,0 85 1100 700x400 35 1" 35 3 80 175 4,2 245 8,4 85 1350 700x400 50 1" 50 3,5 90 250 6,0 350 12,0 85 1750 700x400 70 1" 70 4 100 350 8,4 490 16,8 200 1600 900x500 90 1" 90 4,3 110 450 10,8 630 21,6 200 1850 1000x500 110 1" 110 4,5 110 550 13,2 770 26,4 200 1850 1000x500 130 1" 130 4,7 120 650 15,6 910 31,2 200 1850 1000x500 150 1" 150 5 140 750 18,0 1050 36,0 200 1850 1000x500 130 1 1/2" 130 10 120 650 15,6 910 31,2 200 1850 1000x500 150 1 1/2" 150 12 130 750 18,0 1050 36,0 200 1850 1000x500 200 1 1/2" 200 15 180 1000 24,0 1400 48,0 300 1800 1300x700 250 1 1/2" 250 15 180 1250 30,0 1750 60,0 300 1800 1300x700 300 1 1/2" 300 15 180 1500 36,0 2100 72,0 500 2000 1500x900 Modelli di potenzialità superiore sono fornibili e vengono proposti nel caso speci co, con relativi accessori Models of higher capacities are available and they are proposed in the speci c case, with the respective accessories 2

ADDOLCITORI DUPLEX HLWX/n Gli addolcitori Duplex sono costituiti da due unità in parallelo, funzionanti alternativamente, per la fornitura continua di acqua addolcita. ADDOLCITORI CABINATI HC/n La versione cabinata, mod. HC/ n, automatica a tempo, è proposta a fini estetici, per utilizzi domestici e per particolari attività (bar, ristoranti, studi dentistici, etc.). DUPLEX SOFTENERS HLWX/n The Duplex softeners are composed by two parallel units, alternatively working, to assure the uninterrupted supply of softener water. CABINET SOFTENERS HC/N The cabinet version, HC/n mod., automatic time control type, is proposed as model for esthetic aim, domestic uses and particoular activities (e.g. bar, restaurant, dentist, etc.). ADDOLCITORE CABINATO CABINET SOFTENER ADDOLCITORE CABINATO E TEST KIT DUREZZA ACQUA CABINET SOFTENER AND WATER HARDNESS TEST KIT Tipo Model Attacchi Connect. Volume resina Resin volume Portata massima Maximum ow Perdita di carico Pressure drop Portata ciclica e consumo sale per rigener. Cyclic ow and salt consump on per regener. Larghezza Lunghezza Altezza Width Length Height HC/n Media/Medium Massima/Maximum I m³/h kpa m³. F Kg m³. F Kg mm mm mm 8 1'' 8 0,5 50 40 1,0 56 2,0 320 520 740 10 1'' 10 0,7 50 50 1,2 70 2,4 320 520 740 15 1'' 15 1 50 75 1,8 105 3,6 320 520 1040 25 1'' 25 1,5 50 125 3,0 175 6,0 320 520 1160 Modelli di potenzialità superiore sono fornibili e vengono proposti nel caso speci co, con relativi accessori Models of higher capacities are available and they are proposed in the speci c case, with the respective accessories 3

ADDOLCITORI D I componenti standard sono: Colonna in acciaio zincato a bagno Resina scambiatrice Valvole di servizio: operano a comando idraulico e/o pneumatico Programmatore per funzionamento automatico accoppiato a sistema di servo azionamento valvole Manometri controllo pressione Prese campione Eiettore per l'aspirazione della salamoia Serbatoio di preparazione e stoccaggio salamoia SOFTENERS D The standard components are: Galvanized steel column Ion-exchange resin Service valves: hydraulically or pneumatically controlled Program unit for automatic functioning along with servo control of valves Pressure indicators Water samplers Ejector for brine suction Brine preparation and storage tank ADDOLCITORE D SOFTENERS D ADDOLCITORE DUPLEX DWX DUPLEX SOFTENERS DWX Tipo Model Attacchi Connect. Volume resina Resin volume Portata massima Maximum ow Perdita di carico Pressure drop Portata ciclica e consumo sale per rigener. Cyclic ow and salt consump on per regener. Altezza totale Total Height Ingombro in pianta (con serbatoio) Plan dimensions (with tank) D Media/Medium Massima/Maximum I m³/h kpa m³. F Kg m³. F Kg mm mm 500 1 1/2'' 250 12 150 1170 33 1670 50 2000 1500x1100 600 1 1/2'' 300 16 150 1410 39 1950 60 350 16 190 1650 46 2300 70 600 2'' 300 19 150 1410 39 1950 60 350 19 180 1650 46 2300 70 2100 1900x1300 700 800 2'' 2'' 400 525 22 22 140 130 1900 2480 52 69 2600 3480 80 105 450 600 22 22 180 140 2120 2820 59 78 2900 3900 90 120 2100 2100 2100x1500 2300x1500 900 2 1/2'' 750 30 110 3530 98 4900 150 900 30 130 4230 117 5800 180 2500 2500x1600 1100 3'' 1100 45 110 5160 145 7150 220 1300 45 140 6100 170 8500 260 2600 2800x1700 Modelli di potenzialità superiore sono fornibili e vengono proposti nel caso speci co, con relativi accessori Models of higher capacities are available and they are proposed in the speci c case, with the respective accessories 4

SISTEMA AUTOMATICO DI DISINFEZIONE RESINE A COSA SERVE Il sistema, che agisce per mezzo dell elettrolisi, serve in modo specifico per la sterilizzazione dei letti di resina degli addolcitori destinati ad uso potabile. Tale sterilizzazione avviene per mezzo del cloro che viene prodotto sfruttando la soluzione satura di salamoia formatasi nell apposito contenitore. AUTOMATIC SYSTEM FOR THE DISINFECTION OF RESINS WHEN IT IS USED The system, exploiting the electrolysis, is specifically used for the sterilization of the softeners resin bed for drinkable purposes. The sterilization is accomplished by means of chlorine produced by the saturated brine solution collected in the specific tank. APPLICAZIONE Il produttore di cloro per la sterilizzazione degli addolcitori, grazie alla sua concezione, si presta ottimamente per essere installato su tutti i tipi di valvole operatrici, sia semiautomatiche che automatiche. Lo stesso può essere installato facilmente anche su addolcitori già funzionanti e la sua installazione non richiede nessuna modifica alla valvola operatrice. APPLICATION The chlorine producer for the sterilization of the softeners, thanks to its design, is also fit for installation on every kind of operating valves, both semiautomatic and automatic. It can also be easily installed on already running softeners and its installation doesn t require any modification to the operating valve. COMPONENTI Il sistema si compone di: a) centralina di controllo e di regolazione b) cavo di alimentazione c) elettrodo di elettrolisi con relativo cavo di colle gamento CARATTERISTICHE TECNICHE alimentazione centralina: 230 V - 5Hz potenza assorbita: max. 20 Watt/h (in fase di elettrolisi) alimentazione elettrodo : circa 6,5 V CC materiale elettrodo: grafite durata elettrodo: circa 120 h/lavoro (circa un anno) 1 2 4 COMPONENTS The system consists in: a) control and adjustment unit b) power load c) electrolysis electrode with respective connetion cable TECHNlCAL DATA Switch unit power supply: 230 V - 5Hz Current absorption: max. 20 Watt/h (during the electrolysis) Electrode power supply: about 6,5 V CC Electrode material: graphite Electrode life: about 120 h / work (about 1 year) SCHEMA DI INSTALLAZIONE E FUNZIONAMENTO (Versione Volumetrica) INSTALLATION AND RUNNING DIAGRAM (Meter initiated version) 3 5 6 1) Centralina di controllo 1) Control unit 2) Valvola operatrice 2) Operating valve 3) Addolcitore 3) Softener 4) Cella 4) Cell 5) Salamoia 5) Brine 6) Sale 6) Salt 5

IMPIEGO OTTIMALE DUREZZA MASSIMA: 50 F TEMPERATURA MASSIMA: 45 C PRESSIONE MINIMA DELL ACQUA: 200 KPA PRESSIONE MASSIMA DELL ACQUA: 600 KPA INFORMAZIONI GENERALI Per la rigenerazione si consiglia l impiego di NaCI in pastiglie, che possiede un grado di purezza maggiore di quello industriale. Tensione di alimentazione standard 230 V 50Hz monofase. OPTIMUM UTILIZATIONS MAXIMUM HARDNESS: 50 F MAXIMUM TEMPERATURE: 45 C MINIMUM WATER PRESSURE: 200 KPA MAXIMUM WATER PRESSURE: 600 KPA GENERAL INFORMATIONS It is recommended the use of NaCI tablets, which are pure at a higher degree than the industriai one. Standard power supply: 230 V 50 Hz single phase. GARANZIA ED ASSISTENZA TECNICA Ogni apparecchio viene accuratamente controllato in ogni suo particolare ed è quindi garantito da difetti di costruzione. È inoltre prevista la garanzia di un anno con sostituzione gratuita di eventuali pezzi difettosi. La nostra organizzazione di assistenza tecnica è sempre a Vostra disposizione per ogni evenienza. NOTA: unitamente all apparecchio viene fornito un dettagliato manuale di installazione uso e manutenzione. WARRANTY AND TECHNlCAL ASSISTANCE AIl the appliances are quality controlled in every single part and they are thus guaranteed against manufacturing defects. One-year warranty with free replacement of the parts in case of defects, is included. Our technical assistance is always at Your service. NOTE: along with the plant a detailed installation, usage, and maintenance manual is supplied. L Acqua addolcita riduce notevolmente i costi energetici ed il consumo di detersivi, riducendo così l impatto ambientale The softener Water cut down considerably the energy costs and the washing power consumption, so to decrease the environmental impact pow 6

Depurazione acque re ue civili Depurazione acque re ue industriali Tra amento acque meteoriche Recupero e riu lizzo delle acque Acque primarie e potabilizzazione Civil wastewater treatment Industrial wastewater treatment Rainwater treatment Recovery and reuse of the water rimary water and uri ca on ra amento dei ri u Impian per il tra amento dei ri u solidi organici Waste treatment Solid organic waste treatment plants Deodorizzazione dell aria Impian di bio ltrazione ir deodori a on Bio ltra on plants Sistemi per la produzione di biogas ed energia ele rica Impian fotovoltaici Solare termico Biogas from biomasses Biogas from waste Renewable energy from solar panel www.idro.net