CATALOGUE WATER TREATMENT division SWIMMING POOLdivision COOLING TOWER division INDUSTRIAL division
|
|
- Sabrina Leone
- 8 anni fa
- Visualizzazioni
Transcript
1 CATALOGUE WATER TREATMENT division SWIMMING POOLdivision COOLING TOWER division INDUSTRIAL division
2 SWIMMI NG POOL NASCE CON L OBBIETTIVO DI OFFRIRE AI NOSTRI CLIENTI UNA GAMMA COMPLETA DI PRODOTTI SPECIFICI PER IL SETTORE. THIS SECTOR HAS BEEN DEVELOPED TO OFFER TO OUR CUSTOMERS A COMPLETE OF SPECIFIC PRODUCTS FOR SWIMMING POOLS elec t r omagnetic p ro duc t s s y s t e m p ro duc t s uv sy s t e m p ro duc t s DIVISION
3 ATHENASERIES POMPA DOSATRICE ELETTROMAGNETICHE ELECTROMAGNETIC DOSING PUMP AT.PR OLIMPIASERIES POMPA DOSATRICE ELETTROMAGNETICHE ELECTROMAGNETIC DOSING PUMP ATHENA DIGITALE A PROPORZIONALE CON STRUMENTO ph/rx DI MISURA ph 4 - RX mv COMPENSAZIONE AUTOMATICA/MANUALE DELLA TEMPERATURA (ph) USCITA 4 ma SU TUT TA LA SCALA PER REGISTRAZIONE CALIBRAZIONE AUTOMATICA /MANUALE CON INDICAZIONE EFFICIENZA DELLA SONDA DIGITAL PROPORTIONAL FLOW WITH ph/rx INSTRUMENTS ph 4 - RX mv MEASURING MANUAL/AUTOMATIC TEMPERATURE COMPENSATION (ph) 4 ma OUTPUT ON ALL THE RECORDING SCALE MANUAL / AUTOMATIC CALIBRATION WITH PROBE EFFICIENCY EVALUATION ANALOGICA A COSTANTE CASSA IN POLIPROPILENE IGNIFUGA E ANTIACIDO REGOLAZIONE MANUALE DELLA % VALVOLA DI ADESCAMENTO MANUALE ALIMENTAZIONE 4 Vac (4V SU RICHIESTA) ALIMENTAZIONE ED INGRESSO SONDA DI LIVELLO CON ATTACCO RAPIDO LED CON STATO DI FUNZIONAMENTO PROTEZIONE IP 5 ANALOGIC WITH COSTANT FLOW FIREPROOF AND ANTI-ACID POLYPROPYLENE BOX % MANUALLY ADJUSTABLE MANUAL PRIMING VALVE 4 Vac POWER SUPPLY (4V UPON REQUEST) POWER SUPPLY AND LEVEL PROBE INLET WITH QUICK CONNECTION WORKING STATE LED IP 5 PROTECTION DEGREE S PRESSIONI S CC/Imp. CC/Strokes CONNESSIONI CONNECTIONS IMP./min. STROKES/min. ASSORBIMENTO CONSUMPTION PESO WEIGHT 3 l/h bar,3 4x 4 Watt 3 kg 4 l/h bar,4 5 l/h 8 bar,5 8 l/h bar, ATHENA 3 S PRESSIONI S CC/Imp. CC/Strokes CONNESSIONI CONNECTIONS IMP./min. STROKES/min. ASSORBIMENTO CONSUMPTION PESO WEIGHT 7 l/h bar,39 4x 3 8 Watt 4 kg l/h bar,55 4 l/h bar,78 l/h bar, OL.BP S PRESSIONI S CC/Imp. CC/Strokes CONNESSIONI CONNECTIONS IMP./min. STROKES/min. ASSORBIMENTO CONSUMPTION PESO WEIGHT 5,5 l/h bar,5 4x/4x7 mm 4 Watt 3 kg l/h bar ATHENA S PRESSIONI S CC/Imp. CC/Strokes CONNESSIONI CONNECTIONS IMP./min. STROKES/min. ASSORBIMENTO CONSUMPTION PESO WEIGHT l/h 5 bar, 8x 3 8 Watt 4 kg l/h 4 bar, 35 l/h bar,94 5 l/h, bar,
4 BIO.TEMPSERIES SISTEMA di DOSAGGIO TEMPORIZZATO TEMPORISED DOSING SYSTEM ELITESERIES ELITE.pH / Rx DOSAGGIO FLOCCULANTE ED ESSENZE DOSAGGIO CON OROLOGIO SETTIMANALE RELÉ FUNZIONE ATTIVAZIONE AFTER/BEFORE CONTROLLO LIVELLO SERBATOIO INTERRUTTORE ON/OFF/ADESCAMENTO DISPLAY X (BLU-BIANCO) INGRESSO IN TENSIONE 4 Vac SEGNALE ELETTRICO DALLA POMPA DI RICIRCOLO ALLARME REMOTO VIA RELÉ (CONTATTO PULITO) SETTAGGIO DEI PARAMETRI VIA MENÙ SISTEMA DOSAGGIO ph e Rx VERSIONE SINGOLA POMPA ph and Rx DOSING SYSTEM SINGLE PUMP VERSION ph -, 8,,5 5 lt/h,5 bar Rx mv 93 mv FLOCCULENT AND ESSENCES DOSING DOSING WITH WEEKLY TIMER TANK LEVEL CONTROL ON/OFF/SWITCH-PRIMING X DISPLAY (BLUE-WHITE) TENSION INPUT 4 Vac ELECTRICAL SIGNAL FROM CIRCULATING PUMPS REMOTE ALARM THROUGH RELAYS (DRY CONTACT) SETTING OF THE PARAMETERS VIA MENU ELITE PLUSSERIES DATI SISTEMA ELITE.PR DOSAGGIO PROPORZIONALE TRAMITE LA MISURA DEL ph E DEL Redox S PRESSIONI S ALIMENTAZIONE POWER SUPPLY,5 5 ml/h,5 bar 4 Vac 5, 5 ml/h 8 8 ml/h ml/h 9 9 ml/h PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph AND Redox SYSTEM DATA ph - 4,5 5 lt/h,5 bar Rx -. mv
5 ELITE PLUSSERIES DATI SISTEMA ELITE.PR ph-/ph+ DATI SISTEMA ELITE.PHP SISTEMA DI DOSAGGIO PROPORZIONALE PER REGOLARE I VALORI DI ph MINUS e ph PLUS TRAMITE SINGOLA MISURA DEL ph SISTEMA DI DOSAGGIO PROPORZIONALE PER LA REGOLAZIONE DEL ph E DOSAGGIO TEMPORIZZATO PER IL PEROSSIDO DI IDROGENO (HO) PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph MINUS AND ph PLUS WITH SINGLE MEASURE ph SYSTEM DATA PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph AND TIMED DOSING METHOD TO ADJUST HYDROGEN PEROXIDE (HO) SYSTEM DATA ph - /ph + - 4,5 5 lt/h,5 bar ph - 4,5 5 lt/h,5 bar DATI SISTEMA ELITE.PF DATI SISTEMA ELITE.PR ph - /ph + /RX SISTEMA DI DOSAGGIO PROPORZIONALE PER LA REGOLAZIONE DEL ph E DOSAGGIO TEMPORIZZATO PER IL FLOCCULANTE PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph AND TIMED DOSING METHOD TO ADJUST FLOCCULENT SISTEMA DI DOSAGGIO PROPORZIONALE PER LA REGOLAZIONE DEL ph / Redox / ph+ PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph / ph+ / Redox SYSTEM DATA SYSTEM DATA ph - 4,5 5 lt/h,5 bar ph - /ph + - 4,5 5 lt/h,5 bar Rx - mv 9 9
6 ELITE PLUSSERIES DATI SISTEMA ELITE.PRF ELITE.PRF CON VASCA DI ATTIVAZIONE WITH ACTIVATION POOL SISTEMA DI DOSAGGIO PROPORZIONALE PER LA REGOLAZIONE DEL ph / Redox / FLOCCULANTE PROPORTIONAL DOSING SYSTEM AND TO ADJUST ph / Redox / FLOCCULENT SYSTEM DATA REGOLATORE PH / REDOX AND FLOCCULANTE OROLOGIO SETTIMANALE PER CONTROLLO BOILER E POMPA DI RICIRCOLO CONTROLLER PH / REDOX AND FLOCCULENT WEEKLY TIMER TO CONTROL BOILER AND CIRCULATION PUMP DATI SISTEMA SYSTEM DATA ph- 4, Rx- mv,5 5 lt/h,5 bar Flocculent ph - 4,5 5 lt/h,5 bar Rx -. mv Flocculent ELITE.PR CON VASCA DI ATTIVAZIONE WITH ACTIVATION POOL REGOLATORE PH E REDOX OROLOGIO SETTIMANALE PER CONTROLLO BOILER E POMPA DI RICIRCOLO CONTROLLER PH AND REDOX WEEKLY TIMER TO CONTROL BOILER AND CIRCULATION PUMP DATI SISTEMA SYSTEM DATA ph - 4,5 5 lt/h,5 bar Rx -. mv
7 ELITESERIES SISTEMI AUTOMATICI DI CONTROLLO HELIOSSERIES AUTOMATIC CONTROL SYSTEMS ELITE.SP PR HELIOS. ph lt/h 5 bar Rx - +. mv ph - ±, Rx - ± mv SISTEMA DI DOSAGGIO COMPOSTO DA STRUMENTO CON DOPPIA MISURA E POMPE DOSATRICI ELETTROMAGNETICHE, ADATTO PER LA MISURA DEL PH E DEL REDOX (ORP) IN APPLICAZIONI DOVE È RICHIESTO UN DOSAGGIO CON CONTRO FINO A 5 bar ALLARME REMOTO TRAMITE UN RELÉ SPECIFICO DOSAGGIO PROPORZIONALE AUTOMATICO CALIBRAZIONE AUTOMATICA DELLE SONDE IL SISTEMA E' DISPONIBILE ASSEMBLATO SU PANNELLO, COMPLETO DEGLI ACCESSORI VERSIONE A SINGOLA POMPA IT IS AN EASY TO USE DOSING SYSTEM COMPOSED OF A CONTROL INSTRUMENT WITH DOUBLE MEASUREMENT AND SOLENOID DOSING PUMPS. THIS SYSTEM IS THE RIGHT SOLUTION TO CONTROL PH OR REDOX (ORP) IN THOSE APPLICATIONS WERE IT IS REQUIRED TO DOSE UP TO 5 bar. RELAY OUPUT FOR REMOTE ALARM AUTOMATIC PROPORTIONAL DOSING AUTOMATIC CALIBRATION PROBES THE SYSTEM IS ALSO AVAILABLE ALREADY ASSEMBLED ON A PANEL, COMPLETE WITH ACCESSORIES SINGLE PUMP VERSION VISUALIZZAZIONE VISUALIZATION ACCURATEZZA ACCURAC Y ph - ±, Rx - ±3 mv ALIMENTAZIONE POWER SUPPLY 4 Vac 5/ Hz ASSORBIMENTO CONSUPTION / 8 W PANNELLO DIGITALE COMPOSTO DA: POMPA ELETTROMAGNETICA DIGITALE CON STRUMENTO ph O REDOX (ORP) INCORPORATO SONDA DI ph, SONDA DI REDOX E SONDE DI BASSO LIVELLO PORTASONDA A DEFLUSSO CON SENSORE DI FLUSSO IN PLEXIGLASS FILTRO PANNELLO IN PVC 4X CM SOLUZIONI TAMPONE (ph-redox) IL TUTTO MONTATO E CABLATO PRONTO PER ESSERE INSTALLATO DIGITAL PANEL SUPPLIED WITH: DIGITAL ELECTROMAGNETIC PUMP WITH BUILT-IN ph OR REDOX (ORP) ph PROBE, REDOX PROBE AND LOW LEVEL PROBE BATH TYPE PROBE HOLDER WITH PLEXIGLASS FLOW SENSOR FILTER PVC PANEL 4X CM BUFFER SOLUTIONS (ph-redox) ALL ASSEMBLED AND CABLED READY TO BE INSTALLED HELIOS. PANNELLO PROPORZIONALE COMPOSTO DA: POMPE DOSATRICI ANALOGICHE MULTIFUNZIONE STRUMENTI DI MISURA NEXUS.SERIES SONDA DI PH, SONDA DI REDOX E SONDE DI BASSO LIVELLO PORTASONDA A DEFLUSSO CON SENSORE DI FLUSSO IN PLEXIGLASS FILTRO PANNELLO IN PVC 8X CM SOLUZIONI TAMPONE (PH-REDOX) IL TUTTO MONTATO E CABLATO PRONTO PER ESSERE INSTALLATO PROPORTIONAL PANEL SUPPLIED WITH: ANALOGIC MULTIFUCTION DOSING PUMPS NEXUS.SERIES INSTRUMENTS PH PROBE, REDOX PROBE AND LOW LEVEL PROBE BATH TYPE PROBE HOLDER WITH PLEXIGLASS FLOW SENSOR FILTER PVC PANEL 8X CM BUFFER SOLUTIONS (PH-REDOX) ALL ASSEMBLED AND CABLED READY TO BE INSTALLED 3 4
8 HELIOSSERIES HELIOS.3 HELIOS.4 PANNELLO DIGITALE COMPOSTO DA: POMPE DOSATRICI DIGITALI MULTIFUNZIONE / OLIMPIA CENTRALINA MULTIPARAMETRICA ph CL T SONDA DI ph, SONDA DI CLORO D.CL 3 CON SENSORE DI FLUSSO, SONDA DI TEMPERATURA E SONDE DI BASSO LIVELLO FILTRO PANNELLO IN PVC 8X cm SOLUZIONI TAMPONE (ph) IL TUTTO MONTATO E CABLATO PRONTO PER ESSERE INSTALLATO DIGITAL PANEL SUPPLIED WITH: DIGITAL MULTIFUNCTION DOSING PUMPS / OLIMPIA ph CL T MULTIPARAMETER SWITCH BOARD ph PROBE, D.CL 3 CHLORINE PROBE WITH FLOW SENSOR, TEMPERATURE PROBE AND LOW LEVEL PROBE FILTER PVC PANEL 8X cm BUFFER SOLUTIONS (ph) ALL ASSEMBLED AND CABLED READY TO BE INSTALLED RS485 portseries DISPONIBILE IL SISTEMA CON LA PORTA SERIALE RS485 e PROTOCOLLO MODBUS PER EFFET TUARE TRASMISSIONE DATI VIA CAVO VERSO PERSONAL COMPUTER GRAZIE AL SOFTWARE DEDICATO REMOTE CABLE CONTROLLER È POSSIBILE REGISTRARE I DATI DI MISURA IN TEMPO REALE DI CLORO, ph E TEMPERATURA IN MODO ESTREMAMENTE SEMPLICE THE SYSTEM IS AVAILABLE WITH RS485 PORT and MODBUS PROTOCOL TO ENABLE CABLE DATA TRANSMISSION TO PC AS A RESULT OF THE REMOTE CABLE CONTROLLER SOFTWARE IT'S POSSIBLE TO SAVE CHLORINE, PH AND TEMPERATURE MEASURING DATA IN REAL TIME SISTEMA POTENZIOSTATICO COMPOSTO DA: STRUMENTO DI MISURA NEXUS.SERIES SONDA DI CLORO POTENZIOSTATICA REGOLATORE DI FLUSSO PANNELLO IN PVC 8X7 cm IL TUTTO MONTATO E CABLATO PRONTO PER ESSERE INSTALLATO POTENTIOSTATIC SYSTEM SUPPLIED WITH: NEXUS.SERIES INSTRUMENTS POTENTIOSTATIC CHLORINE PROBE FLOW REGULATOR PVC PANEL 8X7 CM ALL ASSEMBLED AND CABLED READY TO BE INSTALLED HELIOS.MP SISTEMA CONTROLLO ph/cl POTENZIOSTATICO COMPOSTO DA: POMPA DOSATRICE MULTIFUNZIONE ph ( 4) POMPA DOSATRICE MULTIFUNZIONE CL ( a ppm) ph/cl POTENTIOSTATIC CONTROL SYSTEM SUPPLIED WITH: POMPA DOSATRICE MULTIFUNZIONE ph ( 4) POMPA DOSATRICE MULTIFUNZIONE CL ( a ppm) La rete di trasmissione prevede la gestione simultanea di sei () pannelli HELIOS.3 PC. Con un unico cavo Hardware Seriale RS485/USB. si ha la possibilità di collegare il tut to al Computer e gestire tut ti i parametri del sistema con un unico sof t ware Il Sof t ware di gestione permet te di gestire un modem GPRS esterno (Opzionale) collegato al computer per The transmission net work could work with up to panels (HELIOS.3 PC). With a single 3 wire cable and when using a Hardware Serial Adaptor RS485/USB., it is possible to connec t the whole system to a PC and to manage all the parameters using a single sof t ware The managing sof t ware allows the control of a GPRS modem (optional) connec ted to the PC to send SMS alarms when needed for a prompt solution to any problem DATI TECNICI POMPE ATHENA ATHENA PUMPS TECHNICAL DATA S PRESSIONI S CC/Imp. CC/Strokes CONNESSIONI CONNECTIONS IMP./min. STROKES/min. ASSORBIMENTO CONSUMPTION PESO WEIGHT 3 l/h bar,3 4x 4 Watt 3 kg 4 l/h bar,4 5 l/h 8 bar,5 8 l/h bar,
9 INSTALLAZIONI INSTALLATIONS PRIVATEPOOL INSTALLAZIONI INSTALLATIONS SEMI-PUBLICPOOL water INLET ph water INLET CL water OUTLET water OUTLET water INLET ph water INLET CL water OUTLET water OUTLET FLOCCULENT ANTI-ALGAE BIO.TEMPSERIES SISTEMA DI MISURA FLOCCULANTE o ANTI-ALGHE FLOCCULENT or ANTI-ALGAE DOSING SYSTEM HELIOS.SERIES MISURA E DOSAGGIO SISTEMI ph/rx ELITE.SP PRSERIES ph/rx SYSTEMS FOR MEASURE AND DOSING ATHENA.PRSERIES HELIOS.3SERIES SISTEMA DI MISURA CON DOSAGGIO ph/cl/ppm MEASURE SYSTEM WITH ph/cl/ppm DOSING 7 8
10 HELIOSSERIES HELIOS.5 PANNELLO DIGITALE COMPOSTO DA: POMPE DOSATRICI MULTIFUNZIONE CENTRALINA MULTIPARAMETRICA NEXUS.7 SONDA DI ph, SONDA DI CLORO CON SENSORE DI FLUSSO REGOLABILE, RUBINET TO PRELIEVO CAMPIONE, FILTRO DEGASAGGIO SONDE DI BASSO LIVELLO PANNELLO IN PVC 8X cm SOLUZIONI TAMPONE (ph/rx) IL TUTTO MONTATO E CABLATO PRONTO PER ESSERE INSTALLATO DIGITAL PANEL SUPPLIED WITH: MULTIFUNC TION DOSING PUMPS NEXUS.7 MULTIPARAMETER SWITCH BOARD ph PROBE, CHLORINE PROBE WITH REGULABLE FLOW SENSOR, SAMPLE WATER FAUCET, DEGASSING FILTER PVC PANEL 8X cm BUFFER SOLUTIONS (ph/rx) ALL ASSEMBLED AND CABLED READY TO BE INSTALLED INSTALLAZIONE COMPLE TA COMPLE TE INSTALLATION Ingresso tubo 8x Inlet tube 8x Filtro Degasaggio Degassing Filter 3 Sensore Reed Reed Sensor 4 Portasonda ph /Rx (ORP) ph/rx (ORP) probe holder 5 Uscita Tubo 8x Outlet tube 8x Cella Amperometrica Amperometric Cell 7 Rubinetto Prelievo Campione Acqua Sample Water Faucet 8 Rubinetto Regolazione Flusso Flow Regulation Faucet 9 Cartuccia Filtro Filter Cartridge 9
11 Chlorine.Meter COLORIMETRO INDUSTRIALE E MULTIFUNZIONE MULTIFUCTION INDUSTRIAL CHLORINE METER DI.FO INSTALLAZIONI INSTALLATIONS PUBLICPOOL RELÈ D'USCITA CONFIGURABILI COME SET-POINT, ALLARMI DI MASSIMA, ALLARMI DI MINIMA, PWM (regolazione proporzionale nel tempo), PFM (regolazione proporzionale ad impulsi), AUTOPULIZIA POSSIBILITÀ DI AVERE IN USCITA BASSA TENSIONE 4V (pilotaggio di piccole dosatrici o elettrovalvole senza l'aggiunta di altri trasformatori e con tensione di sicurezza) SEPARAZIONE GALVANICA TRA INGRESSI/MICROPROCESSORE E USCITE IN CORRENTE INGRESSO OFF per spegnere i relè di regolazione e fermare il ciclo del colorimetro (in piscina va collegato al teleruttore delle pompe Eventuale INGRESSO FLW all'apparecchiatura USCITA "OK" per segnalare a distanza il corretto funzionamento dell'apparecchiatura ALLARMI ED ERRORI (DIAGNOSTICA) visualizzati direttamente sul display. DATARIO/ORARIO (sempre presente anche in assenza di alimentazione) con possibilità di ATTIVARE/DISATTIVARE IL FUNZIONAMENTO DEL COLORIMETRO in fasce orarie prestabilite (es. notte) SALVATAGGIO DEI DATI DEL PROGRAMMA/TARATURA SU MEMORIA NON VOLATILE (ritenzione dati per minimo anni) USCITA SERIALE RS3C per COLLOQUIO/PROGRAMMAZIONE CON PC, PLC disponibile su connettore CANNON 9 pins femmina o in morsettiera su richiesta NIKE.TEMPSERIES DOSAGGIO ANTI-MICOTICO ANTI-FUNGUS DOSING ANTI-ALGAE OUTPUT RELAY AS SET POINTS, MAXIMUM AND MINIMUM ALARMS, PWM (proportional regulation of the time), PFM (proportional pulses regulation), SELF-CLEANING IT IS POSSIBLE TO HAVE LOW VOLTAGE 4V (enabling the monitoring of samller doses with solenoid valves and without the addition of other transformers, with a security power supply) GALVANIC SEPARATION BETWEEN MICROPROCESSOR/ INLETS AND CURRENT OUTLETS OFF INLET relay and to stop the colorimeter cycle (in swimming-pool it has Possible FLW INPUT to "OK" OUTPUT remotely controls the correct intrumentation funtion ALARMS AND ERRORS (DIAGNOSTIC) directly monitorized on the display. DATE/HOUR (always present, also without power supply), with the possibility to START/STOP THE COLORIMETER FUNCTION in pre-set hours (i.e. nightime) PROMGRAMMING & CALIBRATION SAVED IN MEMORY (data holding for years) RS3C SERIAL OUT PUT for PC, PLC connector available on CANNON 9 connection or terminal block water INLET water OUTLET FLOCCULENT BIO.TEMPSERIES SISTEMA DI MISURA FLOCCULANTE o ANTI-ALGHE FLOCCULENT or ANTI-ALGAE DOSING SYSTEM ALIMENTAZIONE POWER SUPPLY CL - ppm CL/pH - ppm / 4, ph CL/pH/Rx/T - ppm / 4, ph /. mv / C /3 Vac - 5/ Hz ±% water INLET water OUTLET BIO.TEMPSERIES CONTROLLO MULTIFUNZIONE MEDIANTE MISURA COLORIMETRICA COLORIMETRIC MULTIFUNCTION CONTROL SYSTEM NX.FLOWSERIES CONTROLLO ACQUA DI SCARICO WATER DRAINING CONTROL SYSTEM
12 POOL.MIXSERIES DISSOLUTORE/DOSATORE DI CLORO CHLORINE DISSOLVER/DOSING Pooltester FOTOMETRO PORTATILE PER USO DOMESTICO PHOTOMETER DESIGNED FOR RESIDENTIAL USE MISCELATORE/DOSATORE DI CLORO. SCOPO DELL APPARECCHIO È SCIOGLIERE I GRANULI DI CLORO (SIA CLORO ISOCIANURATO CHE IPOCLORITO DI CALCIO O DI SODIO) NELL ACQUA DI PISCINA, SECONDO QUANTO RICHIESTO CHLORINE MIXER/PROPORTIONER. THE PURPOSE OF THE UNIT IS TO DISSOLVE GRANULAR CHLORINE (CHLOROISOCYANURATE AS WELL AS CALCIUM OR SODIUM HYPOCHLORITE) IN POOL WATER, ACCORDING TO REQUIREMENTS APPLICAZIONI APPLICATIONS 3 MODI DI UTILIZZO: IL FUNZIONAMENTO MANUALE PREVEDE UNA PRODUZIONE CONTINUA DI CLORO AL DOSAGGIO PRESTABILITO (OV VERO CON I TEMPI PAUSA-LAVORO IMPOSTATI) IL FUNZIONAMENTO AUTOMATICO ON/OFF PREVEDE LA PRODUZIONE DI CLORO AL DOSAGGIO PRESTABILITO SOLO SU CONSENSO ESTERNO (AD ESEMPIO CENTRALINA DI CONTROLLO), UTILIZZANDO I TEMPI DI PAUSA-LAVORO IMPOSTATI IL FUNZIONAMENTO AUTOMATICO PROPOR ZIONALE PRE VEDE UNA PRODUZIONE DI CLORO VARIABILE IN FUNZIONE DEL SEGNALE ANALOGICO IN MA PROVENIENTE DALL A CENTR ALINA DI CONTROLLO (GENER ALMENTE COLORIME TRO). NEL POOL.MIX VANNO IMPOSTATI I TEMPI REL ATIVI ALL A MASSIMA PRODUZIONE. LA VARIAZIONE DI CLORO PRODOT TO SI OT TIENE AGENDO SULLA VELOCITÀ DEL MOTORE COCLEA 3 APPLICATION METHODS: MANUAL OPERATION PROVIDES FOR CONTINUOUS PRODUC TION OF PRE-ESTABLISHED PROPORTIONS OF CHLORINE (I.E. WITH PRESET PAUSE/ WORK TIMES) AUTOMATIC ON-OFF OPERATION PROVIDES FOR PRODUC TION OF PRE-ESTABLISHED PROPORTIONS OF CHLORINE BASED ON AN EXTERNAL ENABLE SIGNAL (E.G. FROM A CONTROL UNIT), ACCORDING TO SET PAUSE/ WORK TIMES AUTOMATIC PROPORTIONAL OPERATION PROVIDES FOR VARIABLE PRODUC TION OF CHLORINE BASED ON AN ANALOGUE SIGNAL (MA) FROM THE CONTROL UNIT (WHICH IS NORMALLY AN CHLORINE METER). THE TIME SET TINGS FOR MAXIMUM PRODUC TION MUST BE ESTABLISHED IN THE POOL.MIX UNIT. VARIATIONS IN CHLORINE PRODUC TION ARE OBTAINED BY ADJUSTING THE SPEED OF THE SCROLL MOTOR ALIMENTAZIONE POWER SUPPLY CAPACITÁ PRODUTTIVA PRODUCTION CAPACIT Y CARICO TRAMOGGIA HOPPER CAPACIT Y PROGRAMMAZIONE PROGRAMMING PRECISIONE PRECISION PROTEZIONI PROTECTION COLLEGAMENTI ELETTRICI ELECTRICAL CASING CONTENITORE ELETTRONICA ELECTRICAL CASING 3V ~ monofase ±% 5 Hz (elettronica+asservimenti 4V ~) / 4 VA max 3V ~ singlephase ±% 5 Hz (electronic+slaves 4V ~) / 4 VA max 3,5 Kg/h max 3,5 Kg/h max 3 potenziometri, 3 deviatori 3 potentiometer, 3 switches ± % rispetto alla base temporizzazioni ±% with respect to timing basis ABS. W 4 x H 3 x D 5 mm / IP5 / Polyester 4 fusibili 5x, Elettronica (F=F.5A), Secondario 4V~ (F4=FA), Uscita Pompa Ricircolo (F=F3.5A), Uscita Scuotitore (F3=F3.5A) 4 fuses 5x, Electronic (F=F.5A), Secondary 4V~ (F4=FA), Circulator Pump output (F=F3.5A), Shaker Output (F3=F3.5A) Su morsettiere estraibili. Uscita cavi dall unità elettronica con guaina Ø 5 mm + pressacavi PG7/9 per ingresso alimentazione elettrica al timer e consenso da centralina di misura CL On extractable terminal boards. Cable outlet from electronic unit fitted with sheart Ø 5 mm + cable glands PG7/9 foe power supply to timer and enable signal from chlorine measuring unit ALIMENTAZIONE POWER SUPPLY LO STRUMENTO SEGUE I METODI DPD E ROSSO FENOLO, I METODI RICONOSCIUTI A LIVELLO INTERNAZIONALE DAGLI ESPERTI PER VERIFICARE IL LIVELLO DEL CLORO E DEL PH. QUESTO METODO, SEMPLICE E SICURO, ASSEGNA UN DIVERSO TONO DI COLORE CHE VIENE RICONOSCIUTO DALLO STRUMENTO. IL MIGLIOR MODO PER MANTENERE LE PISCINE O VASCHE TERMALI IN PERFETTA CONDIZIONE È CONTROLLARE LA QUALITÀ DELL ACQUA BASATO SUL PRINCIPIO DI MISURAZIONE ELETTRONICO-FOTOMETRICA, È DISPONIBILE PER CHI POSSIEDE PISCINE E ACQUE TERMALI. LE LETTURE AVVENGONO SU LAMINE REAGENTI A LUNGA DURATA CHE VENGONO ACCURATAMENTE MEMORIZZATE LUNGO I CANALI DI LETTURA E UNA BARRA ALL INTERNO DELLO STRUMENTO. LE LAMINE REAGENTI SONO SICURE E FACILI DA UTILIZZARE. NON FUORIESCONO NÉ POLVERI NÉ LIQUIDI. OGNI LAMINA PUÒ ESSERE SOSTITUITA THIS INSTRUMENT IS BASED ON THE DPD AND PHENOL RED METHODS, THE INTERNATIONALLY RECOGNISED METHODS USED BY PROFESSIONALS TO CHECK CHLORINE AND PH LEVELS. THIS EASY AND SAFE TEST METHOD GIVES A DISTINCTIVE COLOUR CHANGE WHICH IS MEASURED BY THE INSTRUMENT. THE BEST WAY TO KEEP A POOL OR SPA IN TOP CONDITION IS TO KEEP A CAREFUL EYE ON THE WATER QUALITY NOW, THE POOLTESTER IS AVAILABLE TO THE POOL AND SPA OWNER BASED ON THE PRINCIPLE OF ELECTRONIC PHOTOMETRIC MEASUREMENTS. THE TESTS ARE BASED ON LONG-LIFE, FOIL-PACKED REAGENT TABLETS THAT ARE ALL CONVENIENTLY STORED ALONG WITH TWO TEST TUBES AND A CRUSHING STICK WITHIN THE INSTRUMENT. THE REAGENT TABLETS ARE SAFE AND EASY TO HANDLE. THERE ARE NO POWDERS OR LIQUIDS TO SPILL. ALL TABLETS ARE AVAILABLE IN HANDY REFILL PACKS ph -,8 8,4 CL -, 5, mg/l Cyn - m/l xpp3 battery (non inclusa not included) PO.VF FOTOMETRO ELETTRONICO COMPATTO COMPACT ELECRONIC PHOTOMETER DATI TECNICI TECHNICAL DATA PRECISIONE PRECISION POTENZA POWER CALIBRAZIONE CALIBRATION TEMPERATURA TEMPERATURE ph/cl/cyn -,8 8,4 -,5 CL - Cn - CL -, 5, mg/l Cyn - m/l, ppm 9 V ( h) automatica automatic 4 C 3 4
13 UV SYSTEMSSERIES Monolamp.SWPSERIES Multilamp.MPSERIES DEBATTERIZZATORE UV A BASSA PER PISCINE, IN GRADO DI EMETTERE RADIAZIONE AD ALTO POTERE MICROBIOCIDA E DI INNESCARE FENOMENI DI FOTOSSIDAZIONE LOW- UV SYSTEM FOR SWIMMING POOL APPLICATIONS EMISSION OF RADIATION WITH A HIGH MICROBICIDAL POWER, CAPABLE OF SETTING OFF PHOTO-OXIDATION PHENOMENA DEBATTERIZZATORE UV MEDIA PER PISCINE, EFFICACE PER AZIONE GERMICIDA, DATA DAI RAGGI UV-C UV MEDIUM FOR SWIMMING POOL, EFFECTIVE GERMICIDE ACTION OF THE UV-C RAYS MONITOR AGGIO EFFE T TUATO (4 ME SI CON FREQUENZA GIORNALIERA) IN UNA VASCA DA m 3 COPERTA AD ELEVATO FLUSSO DI BAGNANTI MONITORING CARRIED OUT OVER A PERIOD OF 4 MONTHS AT DAILY INTERVAL S, IN A m 3 COVERED POOL, WITH A L ARGE NUMBER OF SWIMMERS cloro combinato combined chlorine,,8,4 PRIMA BEFORE valore limite di legge legal limits DOPO AFTER MONITOR AGGIO EFFE T TUATO (4 ME SI CON FREQUENZA GIORNALIERA) IN UNA VASCA DA m 3 COPERTA AD ELEVATO FLUSSO DI BAGNANTI MONITORING CARRIED OUT OVER A PERIOD OF 4 MONTHS AT DAILY INTERVAL S, IN A m 3 COVERED POOL, WITH A L ARGE NUMBER OF SWIMMERS cloro combinato combined chlorine,,8,4 PRIMA BEFORE valore limite di legge legal limits DOPO AFTER MODELLI MODELS N LAMPADE N LAMPS DOSAGGIO DOSING UV.SWP 4 >8 mj/cm (5 h) UV.SWP 7 UV.SWP 5 UV.SWP 8 UV.SWP 35 FLOE RATES 4 m 3 /h 7 m 3 /h 5 m 3 /h 8 m 3 /h 35 m 3 /h RACCORDI CONNECTIONS ALIMENTAZIONE POWER SUPPLY 3 Vac MODELLI MODELS N LAMPADE N LAMPS DOSAGGIO DOSING FLOE RATES RACCORDI CONNECTIONS UV.MP 4 >8 mj/cm (5 h) 4 m 3 /h DN8 UV.MP 9 9 m 3 /h DN UV.MP 3 3 m 3 /h DN5 UV.MP 5 5 m 3 /h DN UV.MP m 3 /h UV.MP 5 5 m 3 /h DN5 UV.MP m 3 /h DN3 UV.MP4 4 m 3 /h DN4 ALIMENTAZIONE POWER SUPPLY 3 Vac 38 Vac 5
14 via F.M. Malfatti, 49 - Vazia (RIETI), ITALY tel r.a. fax info@injecta.com
GEASERIES WATER TREATMENTDIVISION
WATER TREATMENTDIVISION POMPE DOSATRICI ELETTROMAGNETICHE A CORSA E FREQUENZA REGOLABILI ELECTROMAGNETIC DOSING PUMPS WITH ADJUSTABLE STROKES AND FREQUENCY CARATTERISTICHE GENERALI GENERAL FEATURES POMPE
DettagliWATER TREATMENTDIVISION GEASERIES
WATER TREATMENTDIVISION POMPE DOSATRICI ELETTROMAGNETICHE A CORSA E FREQUENZA REGOLABILI ELECTROMAGNETIC DOSING PUMPS WITH ADJUSTABLE STROKES AND FREQUENCY CARATTERISTICHE GENERALI GENERAL FEATURES POMPE
DettagliAthena. the perfect dosing
Athena the perfect dosing Pompa dosatrice elettromagnetica analogica con portata costante Analogic electromagnetic dosing pump with constant flow 1 Pompa dosatrice elettromagnetica analogica con portata
DettagliPratiko M05PHCL M10PHCLMV. Misura e controllo del ph e del potenziale Redox
Sistemi di dosaggio serie M20CP1 - Tecnologia SMD a microprocessore - Display LCD 3 e ½ digit - Nr. 1 uscita relay ausiliaria a contatto libero (allarme o dosatore supplementare) - Dosaggio proporzionale
DettagliPANNELLI ANTILEGIONELLA COD. LEGPANCL
PANNELLI ANTILEGIONELLA COD. LEGPANCL -- DATA SHEET -- Trattamento preventivo legionella per strutture pubbliche. Stazione di dosaggio (in acqua calda) e controllo prodotto sanitizzante e anticorrosivo.
DettagliAlimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)
Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED) Alimentatori elettronici con tensione di uscita stabilizzata per moduli LED di segnalazione. Led driver with
DettagliWATER TREATMENTDIVISION SWIMMING POOLDIVISION COOLING TOWERDIVISION INDUSTRIALDIVISION CATALOGUE2014
WATER TREATMENTDIVISION SWIMMING POOLDIVISION COOLING TOWERDIVISION INDUSTRIALDIVISION CATALOGUE24 COOLING TOWERDIVISION NEXUS.2000SERIES STRUMENTI DI MISURA E CONTROLLO MEASURING AND CONTROL INSTRUMENTS
DettagliOSI I INDUSTR T IAL A E
OSMOSI INDUSTRIALE La linea Euroacque di dissalatori ad osmosi inversa attualmente in produzione è il naturale risultato di oltre trenta anni di esperienza maturata nel trattamento delle acque primarie.
DettagliSTRUMENTI DI CONTROLLO E REGOLAZIONE - SERIE AE CONTROLLERS AND ANALYSERS - AE SERIES
6 STRUMENTI DI CONTROLLO E REGOLAZIONE - SERIE AE AE AE-PH Strumento per la misura e regolazione del ph range 0,00-14,00-2 set-points indipendenti con uscite on/off alimentate - Compensazione manuale della
DettagliMILLIOHM METER PORTATILE 1 MANUALE UTENTE 62000880 PROFESSIONAL ELECTRONIC INSTRUMENTS MILLIOHM - METER
MILLIOHM METER PORTATILE 1 PROFESSIONAL ELECTRONIC INSTRUMENTS MILLIOHM - METER MILLIOHM METER PORTATILE 2 1 Descrizione generale / General description. 3 2 Caratteristiche tecniche/technical Features.
DettagliBVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/33 48 36 Fax 057/33 61 27 info@pomac.be internet: www.pomac.
BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge UNITA LUBETOOL MC-EL-3P-4P-5P-6P-7P, MC-EL-3M-4M-5M-6M-7M, MC-EL-2P E MC- EL-2M Sono forniti completi di scatola di protezione metallica
DettagliMAKOSWATER Nature is the key
MAKOSWATER Nature is the key Makoswater OÜ Narva Maantee 5 7 Tallinn Ph: +37559 WATER TREATMENTDIVISION ATHENASERIES POMPE DOSATRICI ELETTROMAGNETICHE ELECTROMAGNETIC DOSING PUMPS MODELLI MODELS AT.BX
DettagliTERMOREGOLAZIONE TEMPERATURE CONTROL
20 20 TERMOREGOLAZIONE TEMPERATURE CONTROL TERMOSTATI E CRONOTERMOSTATI THERMOSTATS AND CHRONOTHERMOSTATS ART. 9573 Termostato elettronico da incasso Built-in electronic thermostat ART. 9574 Crono digitale
DettagliSerie SDP. Pompe dosatrici elettromagnetiche. The right dosing choice
Serie SP Pompe dosatrici elettromagnetiche The right dosing choice Serie SP Oggigiorno il dosaggio di prodotti chimici liquidi richiede una sempre maggiore precisione e versatilità dei sistemi. oseuro
DettagliPOMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION
POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION VERSIONE MANUALE CON VOLANTINO MANUAL VERSION WITH HANDWHEEL VERSIONE CON COMANDO PNEUMATICO A
DettagliMAKOSWATER Nature is the key
MAKOSWATER Nature is the key Makoswater OÜ Narva Maantee 5 10117 Tallinn Ph: +3725544119 SWIMMING POOLDIVISION ATHENA.PRSERIES POMPE DOSATRICI ELETTROMAGNETICHE ELECTROMAGNETIC DOSING PUMPS DIGITALE A
DettagliTester prova batterie
I modelli proposti Tester prova batterie BT3563 BT3562 3561 3554 Settori di utilizzo Applicazione tipica Linea di Produzione, Controllo Qualità, Ricerca & Sviluppo Batterie ad alta tensione, pacchi batteria
DettagliNOCCHI LA NUOVA GAMMA NOCCHI VSD. engineered solutions. convertitore di frequenza elettronico
NOCCHI LA NUOVA AMMA NOCCHI VSD engineered solutions convertitore di frequenza elettronico NOCCHI VSD VSD (Variable Speed Drive) è un convertitore statico di frequenza in grado di variare la velocità
DettagliOPERA Specifiche tecniche per moduli telegestione Hardware, Quadri di campo e di rete FV
SPECIFICHE TECNICHE OPERA Specifiche tecniche per moduli telegestione Hardware, Quadri di campo e di rete FV RSST04I00 rev. 0 0113 SPECIFICA SIGLA TIPO DI PRODOTTO A DIM/F TELEGESTIONE QUADRI DI CAMPO
DettagliScheda CPU Logika OKIR 510B Irinox cod. 3600160
Connessione per pannello frontale cod. 300 o 3000 Connector for Front panel Board cod. 300 or 3000 Comune 4 Volt / Common 4 Volt Libero / free Clikson ventilatori / fan clikson Pressostato / pressure switch
DettagliWorking data. Dimensioni cassa Dimensions case. Fissaggio Installation. 175x175x100. A parete Wall-fixing. 75x250x100
Quadri elettronici monofase e trifase diretti Direct single-phase and three-phase electronic boards Sistema elettronico adatto per il comando e la protezione di elettropompe sommerse e multistadio con
DettagliCTRL2/6 POOL V CTRL2 POOL V CTRL+ POOL
CTRL POOL IL SISTEMA SEMPLICE, AFFIDABILE ED ECONOMICO PER PISCINE CTRL POOL è un sistema compatto che include uno strumento singolo o doppio e dispensatori peristaltici. Il CTRL POOL é versatile e facile
DettagliWATER TREATMENTDIVISION ATHENASERIES
WATER TREATMENTDIVISION ATHENASERIES POMPE DOSATRICI ELETTROMAGNETICHE ELECTROMAGNETIC DOSING PUMPS CARATTERISTICHE GENERALI GENERAL FEATURES TESTA IN PVDF adatta per prodotti chimici usati nelle applicazioni
DettagliPool Control 1 ph /cloro con gestione esterna del dosaggio cloro
Splash Control ph/ Redox dei valori di ph e Redox in piscina composto da: pompa serie (2,4 l/h) per acido DF2a 1 pompa serie (2,4 l/h) per cloro DF2a 1 Porta Sonde a deflusso DGMA320T000 1 Sonda Redox
DettagliCaratteristiche V2-S4 V2-S8 V2-S10 V2-S14. Ingressi. Sezione di ciascun cavo DC [mm² ] Da 4 a 10 Da 4 a 10 Da 4 a 10 Da 4 a 10
Descrizione tecnica Caratteristiche V2-S4 V2-S8 V2-S10 V2-S14 Ingressi Max. tensione di ingresso 1000 1000 1000 1000 Canali di misura 4 8 10 14 Max corrente Idc per ciascun canale [A] 20 (*) 20 (*) 20
DettagliMod. 1067 INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003
Mod. 1067 DS1067-019 LBT8388 INTERFACCIA USB/KEY USB/KEY INTERFACE Sch./Ref.1067/003 ITALIANO DESCRIZIONE GENERALE L interfaccia 1067/003 consente di collegare alla Centrale 1067/032 o 1067/042 (ver. 2.00
DettagliSISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s
SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s Caratteristiche generali Mean features Lampade a bassa tensione (24Vcc) Lamps
DettagliTAURUSSERIES WATER TREATMENTDIVISION POMPE DOSATRICI ELECTROMECCANICHE ELECTROMECHANIC DOSING PUMPS
WATER TREATMENTDIVISION TAURUSSERIES POMPE DOSATRICI ELECTROMECCANICHE ELECTROMECHANIC DOSING PUMPS CARATTERISTICHE GENERALI GENERAL FEATURES IL MECCANISMO DI QUESTE POMPE É DEL TIPO AD ECCENTRICO E PIATTELLO
DettagliCENTRALINE ELETTRONICHE PER IL LAVAGGIO DEI FILTRI PA 12 110/220 02450
CENTRALINE ELETTRONICHE PER IL LAVAGGIO DEI FILTRI SEQUENZIATORE PA Sequenziatore per il controllo del ciclo di pulizia del sistema di depolverazione. Gestione a microprocessore con attivazione delle uscite
DettagliUnità intelligenti serie DAT9000
COMPONENTI PER L ELETTRONICA INDUSTRIALE E IL CONTROLLO DI PROCESSO Unità intelligenti serie DAT9000 NUOVA LINEA 2010 www.datexel.it serie DAT9000 Le principali funzioni da esse supportate, sono le seguenti:
DettagliPUMP CONTROLLER PUMP ACTIVE CONTROLLER
PUMP CONTROLLER PUMP ACTIVE CONTROLLER Technical catalogue Catalogo tecnico rev. 0 del 22/09/2017 PUMP CONTROLLER PUMP ACTIVE CONTROLLER WARNINGS AND LIMITATIONS ON USE The Pump Controller/ Pump Active
DettagliGateway Bacnet Multichiller series
Servizio egolazione e Controllo File Pagina 1/11 Gateway Bacnet Multichiller series Servizio egolazione e Controllo File Pagina 2/11 CONTENTS 1. PCOWEB INSTALLATION... 3 2. BACNET MAPPING... 5 3. PCO COMMUNICATION
DettagliInterfaccia BL232 con uscite RS232/422/485 MODBUS e 0-10V. Interfaccia BL232
BIT LINE STRUMENTAZIONE PER IL MONITORAGGIO AMBIENTALE Interfaccia BL232 con uscite RS232/422/485 MODBUS e 0-10V Facile e rapida installazione Ideale domotica e building automation Alimentazione estesa
DettagliEpta automation R&D TA042-REV0.2
TA042 HIGH SPEED CONTROLLER 128x64 GRAPHICS POSITIVE LCD with LED LIGHT ABSOLUTE TIME KEEPER with NiMh BATTERY RS485 / CAN-OPEN / USB ANALOG & DIGITAL INPUT POWER DIGITAL OUTPUT SUPPLY 86 TO 260 VAC 1/7
DettagliAvvisatori allarme Alarm panels
104 Avvisatori allarme Alarm panels SA1/SLA1...Pag. 106 SLA1+GSM...Pag. 107 LS1...Pag. 108 fourgroup.it 105 SA1/SLA1 Descrizione generale Avvisatore autoalimentato per segnalazione di allarme da contatto
DettagliAnalisi e controllo ZODIAC 2012 133
Analisi e controllo ZODIAC 2012 ZODIAC 2012 133 Dosatori a lambimento Daisy Dosatore galleggiante per pastiglie di cloro. L61012 DOSATORE GALLEGG. DAISY 12,03 un Grey Line Dosatore a lambimento per pastiglie
DettagliCURVATURA - BENDING C50 ES
CURVATURA BENDING CURVATURA BENDING SPESSORE MASSIMO MAX thickness 5 mm Ø 38 4 mm Ø 42 3 mm Ø 50 C50 ES La curvatubi C50 ES è l attrezzatura ideale per piegare tubi rigidi oleodinamici in acciaio inox
DettagliIMPIANTO MODULARE PER IL CONTROLLO DI PROCESSO. Mod. CPMS/EV
IMPIANTO MODULARE PER IL CONTROLLO DI PROCESSO Mod. IMPIANTO MODULARE PER IL CONTROLLO DI PROCESSO Mod. INTRODUZIONE Il sistema di controllo di processo modulare, Mod., costituisce una soluzione flessibile
DettagliCONTROL FAN SYSTEM VENTILATORI BLOWERS. Sistemi di controllo Control Systems SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM
CONTROL FAN SYSTEM SISTEMA DI VENTILAZIONE SALA MACCHINE ENGINE ROOM VENTILATION SYSTEM APPLICAZIONI: Il Control Fan è un sistema di regolazione della velocità utilizzato come controllo a frequenza variabile
DettagliIMP2200/ ITP2200 INVERTER MONOFASE E TRIFASE DA 2200W
INVERTER MONOFASE E TRIFASE DA 2200W SPECIFICHE Tensione alimentazione inverter monofase Tensione alimentazione inverter trifase Corrente max all uscita delle 3 fasi Potenza massima in uscita IP da 100
DettagliCode: GW-IMP-WEB-1. Datalogger web pulses counter. Version 6 inputs with Ethernet. MarCom
Datalogger web pulses counter Code: GW-IMP-WEB-1 Version 6 inputs with Ethernet Datalogger web pulses counter The web datalogger pulses counter is able to count the pulses on digital inputs (2 by default
Dettaglipressostati pressure switches
CODICI DI ORDINAZIONE - ORDER CODES NC [NC] NA [NO] 17.005.0 17.004.0 Corpo: ottone OT 58 0.5 bar 0.05 MPa 48V AC Body: brass OT 58 17.007.0 IP 54 17.008.0 4 CODICE DI ORDINAZIONE - ORDER CODE NC-NA [NC-NO]
DettagliAttuatore a relè Manuale di istruzioni
Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per
DettagliYour home comfort has a new shape. Find out how it works
Your home comfort has a new shape Find out how it works CUBODOMO allows you to manage and monitor your entire home s temperature, from WHEREVER YOU ARE CUBODOMO ti consente di gestire e monitorare la temperatura
DettagliMANUALE di ISTRUZIONI IT 10-11
K330 Output KIT con uscita 4-20mA per Sensore di Flusso a rotore MANUALE di ISTRUZII IT 10-11 Indice 1. Introduzione 2 Istruzioni per la sicurezza. 2 Verifica imballo 2 2. Descrizione.. 2 3. Specifiche
DettagliGuida all installazione del prodotto 4600 in configurazione plip
Guida all installazione del prodotto 4600 in configurazione plip Premessa Questo prodotto è stato pensato e progettato, per poter essere installato, sia sulle vetture provviste di piattaforma CAN che su
Dettagli1. Introduzione 2. Istruzioni per la sicurezza. 2 Verifica imballo 2. 2. Descrizione. 2. 3. Specifiche... 3. Dati Tecnici 3 Dimensioni...
e allarme di MIN per sensore di flusso per basse portate ULF MANUALE di ISTRUZIONI IT 10-11 Indice 1. Introduzione 2 Istruzioni per la sicurezza. 2 Verifica imballo 2 2. Descrizione. 2 3. Specifiche...
DettagliM12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD 10-15. MAIN OUT 90-245V JACK 50/60Hz 3 T1,25A. R 10 60-20 30 mic. line AUX TUNER TAPE CD
M12 X-4 Mixer Preamplifier INPUT VOICE VOICE VOICE VOICE CH1 PIOITY A CH PIOITY AUX TUNE TAPE CD MASTE STEEO MAIN OUT M12 X-4 1 1 1 1 1 1-1 +1-1 +1 1 1 1 CHANNE 1 CHANNE 2 CHANNE3 CHANNE 4 SOUCES VOUME
DettagliTrasmettitore di livello ad ultrasuoni
Trasmettitore di livello ad ultrasuoni 825A105N Dati tecnici Materiale della custodia: PC o Al / PP o PVDF parte bagnata Installazione meccanica: Grado di protezione: IP67 Connessione elettrica: Morsettiere
DettagliAppendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS
Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS I sistemi mod. i-léd SOLAR permettono di alimentare un carico sia in bassa tensione 12-24V DC, sia a 230v AC, tramite alimentazione
DettagliALIMENTATORI POWER SUPPLIES
ALIMENTATORI POWER SUPPLIES GSA Terminali Output Terminals Doppio morsetto per ogni polarità Per una connessione in parallelo facilitata o per utilizzare cavi di sezione minore Double connection for each
DettagliMB-PULSE 4 Product Manual MB-PULSE 4 Manuale Prodotto
MB-PULSE 4 Product Manual MB-PULSE 4 Manuale Prodotto Table of Contents Indice 1. Introduction - Introduzione... 3 2. Technical Data Caratteristiche tecniche... 3 3. Installation Installazione... 4 4.
Dettagliinternational GARDEN LINE CLEANING Revisione 6-09/2013 Cod. 7111352
C L E A N I N G GARDEN LINE international CLEANING Revisione 6-09/2013 Cod. 7111352 Note Tecniche di Prodotto. I dati e le caratteristiche tecniche riportate nel presente Catalogo Generale non sono impegnativi.
DettagliCalcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no.
Calcolo efficienza energetica secondo Regolamento UE n. 327/2011 Energy efficiency calculation according to EU Regulation no. 327/2011 In base alla direttiva ErP e al regolamento UE n. 327/2011, si impone
DettagliSistemi di connessione Distribox e Spiderbox
Distribox and Spiderbox connectivity systems Very small and available in several variants to optimize use of available installation space. Robust design. Available working voltage: 12V, 24V, 110V or 240V;
DettagliBASIC IMC IML QUADRI COMANDO FUNZIONI PRINCIPALI QUADRI COMANDO
QUADRI COMANDO FUNZIONI PRINCIPALI QUADRI COMANDO BASIC Regolazione bruciatore mono e bistadio Regolazione livello ON/OFF Nr.2 livellostato di sicurezza basso livello Nr. 1 livellostato PED di sicurezza
DettagliLa soluzione innovativa CONSUMI IN TEMPO REALE SU CLOUD SEMPLICE E VELOCE DA INSTALLARE PER TUTTI I TIPI DI CONTATORE BASSO COSTO
NEW Gestione illuminazione pubblica da remoto e La soluzione innovativa CONSUMI IN TEMPO REALE SU CLOUD SEMPLICE E VELOCE DA INSTALLARE PER TUTTI I TIPI DI CONTATORE BASSO COSTO per controllare i consumi
DettagliPOMPA PERISTALTICA MP2-HT PH/REDOX
MP2-HT PH/REDOX Pompa peristaltica digitale con strumento di controllo PH/REDOX e temperatura integrato Scelta del tipo di controllo (PH o REDOX) impostabile da software Adatta a dosare prodotti acidi
DettagliPRODUCTION RANGE GAMMA PRODUZIONE
Magnetic switches Miniature reed and electronic magnetic switches. Top mounting possible. Reed and electronic magnetic switches with high switching power. Complete range of mounting accessories to fit
DettagliDATA LOGGER. Modello LR8410/20 LR8400/20 LR8401/20 LR8402/20 LR8431/20 8423. Portate: K, J, E, T, N, R, S, B, W, da -200 C a +2000 C
DATA LOGGER Data Logger Misure Tensione Vcc Modello LR8410/20 LR8400/20 LR8401/20 LR8402/20 LR8431/20 8423 Temperatura termocoppie Temperatura termoresistenze PT100 e jpt100, a +800 C Umidità con sensore
DettagliHD 2717T MISURATORE DI TEMPERATURA E UMIDITÀ UMIDITÀ
HD 2717T MISURATORE DI TEMPERATURA E UMIDITÀ UMIDITÀ Trasmettitore, indicatore, regolatore ON/OFF, datalogger di temperatura e umidità con sonda intercambiabile Gli strumenti Riels della serie HD2717T
DettagliBILANCIAMENTO / BALANCING
BILANCIAMENTO / BALANCING CLIMATE SYSTEMS TECHNOLOGY Informazioni tecniche sulla sezione bilanciamento sono disponibili sul nostro sito web www.pettinaroli.com Technical informations about balancing section
DettagliE-Box Quadri di campo fotovoltaico
Cabur Solar Pagina 3 Quadri di campo fotovoltaico Quadri di stringa con elettronica integrata per monitoraggio e misura potenza/energia CABUR, sempre attenta alle nuove esigenze del mercato, ha sviluppato
DettagliAttuatore a relè Manuale di istruzioni
Attuatore a relè Manuale di istruzioni www.ecodhome.com 1 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 6 Garanzia 2 Introduzione SmartDHOME vi ringrazia per
DettagliPLASMA WELDING ROBOT SISTEMA ROBOTIZZATO PER SALDATURA AL PLASMA. PLASMA WELDING ROBOTIZED SYSTEM. AUTOMATION
PLASMA WELDING ROBOT SISTEMA ROBOTIZZATO PER SALDATURA AL PLASMA. PLASMA WELDING ROBOTIZED SYSTEM. AUTOMATION SCHEMA COLLEGAMENTI - CONNECTION PLAN 01 - Generatore (con pannello di controllo integrato)
DettagliProduct QUADRI ELETTRONICI ELECTRONIC CONTROL PANEL - ECL 1 / ECL 2-
ELECTRONIC CONTROL PANEL - 1 / 2- APPLICAZIONE - APPLICATION - APLICACIÓN Quadro elettronico di avviamento, controllo e protezione, per una (1) o due (2) elettropompe sommergibili monofase (M) o trifase
DettagliGeneratori di Vapore Steam Jet Generator
9 0. 2 0 6. 11 0 0 1 GENERATORE DI VAPORE Versione senza serbatoio. Compatta e facile da usare, questa macchina è dotata di un esclusivo sistema di controllo del livello acqua in caldaia che interrompe
DettagliGateway Bacnet Multichiller series
Servizio egolazione e Controllo File Pagina 1/12 Gateway Bacnet Multichiller series Servizio egolazione e Controllo File Pagina 2/12 CONTENTS 1. PCOWEB INSTALLATION... 3 2. BACNET MAPPING... 5 3. PCO COMMUNICATION
DettagliWEIGHING SYSTEMS SISTEMI DI PESATURA
WEIGHING SYSTEMS SISTEMI DI PESATURA Pesatrice Multiteste mod. FCBS20 Multi-head Weigher mod. FCBS20 Pesatrice a testate multiple dotata di 20 unità di pesatura, comandate da motori passo-passo. Nella
DettagliScaldacqua istantanei a gas ad alta tecnologia. Acquatech
Scaldacqua istantanei a gas ad alta tecnologia Una gamma di prodotti ad alta tecnologia per l acqua calda istantanea Acqua calda subito e senza limiti Risparmio energetico Stabilità della impostata è la
DettagliFLUSSIMETRI DI PURGA - COMMUTATORI - SEZIONE 6.1 PURGE FLOW METER - PNEUMATIC SWITCHES - SECTION 6.1
FLUSSIMETRI DI PURGA - COMMUTATORI - SEZIONE.1 PURGE FLOW METER - PNEUMATIC SWITCHES - SECTION.1 Catalogue SA-7 p. 135 FLUSSIMETRO DI PURGA PURGE FLOW METER Mod. FP I flussimetri di purga con tubo di misura
DettagliENERGY-EFFICIENT HOME VENTILATION SYSTEMS
SISTEMI DI RECUPERO RESIDENZIALE HOME RECOVERY SYSTEMS RECUPERO DI CALORE AD ALTA EFFICIENZA HIGH EFFICIENCY HEAT RECOVERY VENTILAZIONE A BASSO CONSUMO LOW ENERGY VENTILATION SISTEMI DI RICAMBIO CONTROLLATO
DettagliMAKOSWATER high technology leads to perfect performances
MAKOSWATER high technology leads to perfect performances Kuparisepänkatu 2C 31 Kerava, Finland 04250 Phone:+358403602677 www.makoswater.com NEXUSSERIES STRUMENTI DI MISURA E CONTROLLO MEASURING AND CONTROL
DettagliTHR01 THR02 THR03 THV01 THV02 THV03
Termostati THV THR TERMOSTATI Termostato compatto per montaggio su guida DIN 35 mm. Per mezzo di un elemento bimetallico fornisce un contatto normalmente aperto o chiuso. Sono disponibili 2 versioni: THVxx
DettagliBPH-E / DPH-E CIRCOLATORI ELETTRONICI
BPH-E / DPH-E * RISCALDAMENTO, CONDIZIONAMENTO, REFRIGERAZIONE Le pompe elettroniche di circolazione possono essere utilizzate in impianti di riscaldamento, ventilazione e condizionamento per edifici ad
DettagliL unico sistema senza fili per un monitoraggio impeccabile
L unico sistema senza fili per un monitoraggio impeccabile IntellGreen PV è l unico sistema universale senza fili per monitorare in modo completo ed affidabile l impianto fotovoltaico. Caratteristiche
DettagliMAKOSWATER Nature is the key
MAKOSWATER Nature is the key Makoswater OÜ Narva Maantee 5 7 Tallinn Ph: +37559 : 5 : 3 5 m i n % m a x 7 9 : : : - 3 5 7 9 WATER TREATMENTDIVISION ATHENASERIES POMPE DOSATRICI ELETTROMAGNETICHE ELECTROMAGNETIC
DettagliM12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD 10-15 VOLUME BASS HIGH. MAINOUT 90-245V JACK 50/60 Hz 3 T1,25A. R 10 60-20 30 mic.
M12 X-4 Mixer Preamplifier INPUT VOICE VOICE VOICE VOICE CH 1 PIOITY A CH PIOITY AUX TUNE TAPE CD MASTE STEEO MAINOUT M12 X-4 1 1 1 1 1 1-1 +1-1 +1 1 1 1 CHANNE 1 CHANNE 2 CHANNE 3 CHANNE4 SOUCES VOUME
DettagliAddolcitori Softeners
Addolcitori Softeners OASI cabinato - OASI cabin cruisers 4 OASI doppio corpo - OASI double body 5 IDROS - IDROS CAB 6 3 OASI - CABINATO Addolcitori automatici elettronici con RIGENERAZIONE VOLUMETRICA
DettagliINDUSTRIAL SOLUTIONS SERIE M
INDUSTRIAL SOLUTIONS SERIE M Description Descrizione The M Series modules are suitable for installation downstream of air treatment systems/plants, scrubbers or cartridge filters or pipeline sections where
DettagliSPECIFICA TECNICA. Leonardo String Box Control
CARATTERISTICHE SPECIFICA TECNICA Leonardo String Box Control PARAMETRI INGRESSO Range di tensione in Ingresso V 200 900 Max. corrente di stringa A 16 Numero di canali di misura 10 Numero stringhe in ingresso
DettagliHVDP. High Voltage Dynamic Power supply/source. Potenza: in uscita 1, 2.5 e 5kW in DC + sinusoidale.
Milano, 12 Marzo 2015 HVDP High Voltage Dynamic Power supply/source Potenza: in uscita 1, 2.5 e 5kW in DC + sinusoidale. HVDP (High Voltage Dynamic Power) è una famiglia di alimentatori con uscita in DC
DettagliPompe Dosatrici a motore Accessori Parti di ricambio. Motor Driven Dosing Pumps Accessories Spare Parts
2007 Pompe Dosatrici a motore Accessori Parti di ricambio Motor Driven Dosing Pumps Accessories Spare Parts SERIE ST - P / AA ST P / AA SERIES POMPE MECCANICHE A PISTONE: TESTATA AISI 316L MECHANICAL PISTON
DettagliDAISY-OUT SERIES DAISY-OUT
DAISY-OUT SERIES 169 DAISY-OUT SERIES DAISY-OUT DAISY-OUT is a small size fixture with RGB, cold or warm white LEDs designed for exterior recessed applications, suitable for ground mounting purposes. The
DettagliREGOLATORI DI VELOCITA PER SISTEMI DI ASPIRAZIONE PROFESSIONALI E INDUSTRIALI
REGOLATORI DI VELOCITA PER SISTEMI DI ASPIRAZIONE PROFESSIONALI E INDUSTRIALI REGOLATORI DI VELOCITA DA PARETE PER SISTEMI DI ASPIRAZIONE PROFESSIONALI E INDUSTRIALI Progettati secondo i più severi standard
DettagliPROGETTAZIONE. PRODUZIONE. CONSULENZA. È TUTTO SOTTO CONTROLLO.
CATALOGO PISCINE 2 PROGETTAZIONE. PRODUZIONE. CONSULENZA. È TUTTO SOTTO CONTROLLO. Pompe dosatrici Controllo di livello e regolazione della portata Lettura e regolazione ph / Redox Sistemi disponibili
DettagliMINI TRIP PDF MINI TRIP PDF
MINI TRIP PDF DataLogger Modelli via cavo Escort soglie di allarme pre-programmate a richiesta Confezione di n. 10 Mini Trip PDF Data logger temperatura Single Trip (Un solo viaggio) con grado di protezione
DettagliCONFIGURATION MANUAL
RELAY PROTOCOL CONFIGURATION TYPE CONFIGURATION MANUAL Copyright 2010 Data 18.06.2013 Rev. 1 Pag. 1 of 15 1. ENG General connection information for the IEC 61850 board 3 2. ENG Steps to retrieve and connect
DettagliACCESSORI INDICE SHEET TECNICI - ACCESSORI ACCESSORI. UPS ALIMENTATORE STABILIZZATO - Mod. PWS 200/5 PWS200/10 AC030 5
ACCESSORI INDICE SHEET TECNICI - ACCESSORI ACCESSORI NR. SHEET PAG. PANNELLI RIPETITORI ALLARMI mod. AP/1, AP/2, AP/3 e AP4 AC010 2 LAMPEGGIANTE, SIRENE, BUZZER AC020 4 UPS ALIMENTATORE STABILIZZATO -
DettagliParallelamente, il REWIND può essere utilizzato per comunicare con il software di supervisione SICES SUPERVISOR
REWIND: Dispositivo elettronico che, sfruttando la tecnologia GSM/GPRS e abbinato ad gruppo elettrogeno, una torre faro, cisterna/serbatoio, ecc..., consente l invio automatico di pacchetti di dati al
DettagliMultiMeter 44. Trasmettitore-regolatore da 1, 2 o 3 canali. Qualità e buon servizio
MultiMeter 44 Trasmettitore-regolatore da 1, 2 o 3 canali Il MultiMeter 44 è uno strumento modulare che può essere configurato con uno, due o tre canali. Può essere acquistato con un solo canale di misura
Dettaglipowerbox permette di monitorare le prestazioni nel tempo e in tempo reale utilizzando
Tecnologico, compatto ed innovativo, powerbox è una soluzione di automazione e monitoraggio domestico, applicabile nell ambito dell efficienza e dell automazione energetica, idoneo al settore delle fonti
DettagliSCHEDA TECNICA CONTATERMIE
ALLEGATO A15 SCHEDA TECNICA CONTATERMIE CALCOLATORE SVMF3 Campi applicativi SVMF3 é utilizzabile per misura e monitoraggio di impianti di riscaldamento dove sono richieste le piú avanzate funzioni del
DettagliRotorSospension Cube 12
RotorSospension Series RotorSospension Cube 12 Progetto Luce s.r.l. Via XX Settembre 50 - Pomaro Monferrato (AL), Italy, 15040 - Email: info@progetto-luce.it RotorSospension Cube 12 Apparecchio a sospensione
DettagliM 3000 D. monitor respiratorio adatto all uso. su pazienti adulti, bambini e neonati. Codice: 713010 DESTINAZIONE D USO DATI TECNICI
M 3000 D monitor respiratorio adatto all uso su pazienti adulti, bambini e neonati Codice: 713010 Rev: 4 del 16/12/2005 DESTINAZIONE D USO Il monitor respiratorio M 3000 D può essere utilizzato in anestesia
DettagliControllo completo della fertirrigazione
HI 1000 Unità di fertirrigazione HANNA instruments, leader mondiale nella tecnologia di controllo di ph e conducibilità, ha lavorato assieme ai più importanti coltivatori italiani ed esteri per sviluppare
DettagliMODULO IDRAULICO DI INTEGRAZIONE E ACS
MODULO IDRAULICO DI INTEGRAZIONE E ACS Hot sanitary water production and integration hydraulic module Accessori pompe di calore INSTALLAZIONE E USO Installation and use I Il presente documento è da considerarsi
DettagliENERBOX ENERBOX. SEGNALAZIONI Grazie al GSM integrato, in caso di black-out od anomalie, Enerbox invia
ENERBOX ENERBOX COS È ENERBOX è un inverter di tensione che converte la bassa tensione delle batterie in tensione monofase 230V alternata e stabilizzata. In presenza di rete o fonte d energia alternativa,
DettagliRPS TL System. Soluzioni per l energia solare Solutions for solar energy
Soluzioni per l energia solare Solutions for solar energy RPS TL da 280 kwp a 1460 kwp RPS TL from 280 kwp to 1460 kwp RPS TL System L elevata affidabilità e la modularità della costruzione sono solo alcuni
Dettagli