sistemi di disinfezioneuv UVdisinfection systems

Documenti analoghi
LCD 2 domestic series. RACK LCD 2 series. RM series. AM series. 400 series. HDPE series. SMP series. IT series. POOL series.

LCD domestic series. RACK LCD series. RM series. AM series. 400 series. HDPE series. SMP series. IT series. POOL series. COMBI series.

ENERBOX ENERBOX. SEGNALAZIONI Grazie al GSM integrato, in caso di black-out od anomalie, Enerbox invia

Sistema modulare per visualizzazione prezzi carburanti.

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

LCD domestic series. RACK LCD series. 80 RACK DS series. AM series. 400 series. HDPE series. POOL series. SMP series. IT series.

Appendice E - Appendix E PANNELLI FOTOVOLTAICI - PHOTOVOLTAIC PANELS

Avvisatori allarme Alarm panels

Vasche. Bathtub. Calypso

WIN 3 / PROFIBUS. Amplificatore digitale per celle di carico con interfaccia PROFIBUS DP-V1... ITALIANO [Pag. 2-3]

pressostati pressure switches

Vasche. Bathtub. Sense Dual

Genova TIPOLOGIE DI LAMPADE

WORLD OF SITA WATER TREATMENT

IP40 IK04. Sistema lineare professionale modulare per illuminazione a luce diretta o indiretta per interni

Ozone Systems MCP-XT Range

LAMPEGGIANTI A LED HIGHLIGHT LED BEACONS

ECP EXPERT ElEcTRical boards for REfRigERaTing installations

Scheda CPU Logika OKIR 510B Irinox cod

IP68 IK10. Sistema lineare professionale per illuminazione a luce diretta o indiretta per interni, esterni e ambienti sommersi

group STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER CAN J1939 ISOBUS - ISO11783 VT3 SOFTWARE DEVELOPMENT TOOLS IEC 61131

L IMPIEGO DI IMPIANTI UV NELL APPROVVIGIONAMENTO IDROPOTABILE

Copyright 2012 Binary System srl Piacenza ITALIA Via Coppalati, 6 P.IVA info@binarysystem.eu

PRODUCT DATA SHEET. Copernico 500 sospensione - Red TECHNICAL DATA SHEET. Features. Dimensions OPTICS DIMENSIONS LAMP LAMPS INCLUDED ELECTRICAL

Armature per segnalazione ostacoli Obstruction lighting fixtures B - 67

AUTOMAZIONI PER PORTE BATTENTI

A Solar Energy Storage Pilot Power Plant

» K IN L A S R E V 16

quick guide guida rapida J.touch hydromassage bath remote control telecomando per vasche idromassaggio

Installazione interfaccia e software di controllo mediante PC Installing the PC communication interface and control software

CMI-T / CMI-TC / CMI-TD

ELCART. Manuale di istruzioni/scheda tecnica SPECIFICATION

HOLCROFT POWER GENERATOR FOR QUENCHING FURNACE

group HIGH CURRENT MULTIPLEX NODE

Wow Design by Marco Pocci and Claudio Dondoli

SISTEMI DI GUAINE SPIRALATE E RACCORDI GIREVOLI

P r o i e t t o r e a L E D E C O S O L A R

hν = ΔE = E 2 -E 1 E 2

OSI I INDUSTR T IAL A E


Quality Certificates

STAND ALONE LED PV KIT WITH ROAD ARMOR

RPS TL. Solutions for solar energy Soluzioni per l energia solare

sistemi modulari a LED/ modular LED systems

TIAN XIA 500 fluo. Product presentation

Quick start manual Manuale rapido. Version 3.0

Ventilatori centrifughi in linea a bocche rettangolari Rectangular duct centrifugal in-line fans

Banchi aspiranti. Art BANCO ASPIRANTE AD 1 POSTO POLISHING BENCH SINGLE-SEATER

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s

Freni idraulici multidisco serie F Hydraulic Multidisc Brakes F Series

design by Simone Micheli

Registratore H.264 D1 in Tempo Reale

Modulo Module Lumen. Voltaggio Working Voltage

MAIL LE NUOVE APPLIQUE S, L, XL. MAIL is the new wall lamp collection, with indirect light, designed by Alberto Saggia and Valerio Sommella.

Decoro su vetro a parete realizzato da: / Printed on glass to wall realized from:

SUNWAY M PLUS. Inverter solare monofase con trasformatore. Single-phase solar inverter with transformer

ROTARY HERRINGBONE PARALLEL SYSTEM ROTARY SHEEP AND GOATS SYSTEM FOR SHEEP AND GOATS

Your home comfort has a new shape. Find out how it works

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION

24V DC ±10% W. Fluido Fluid. 15 Nl/min

CONFIGURATION MANUAL

Catalogo Catalogue E1W 06-05

Manuale Handbook. Via Torino Piagera di Gabiano (AL) - ITALIA Tel xxxxxx - fax +39 xxxxx. support.race@dimsport.

WELCOME. Go to the link of the official University of Palermo web site Click on the box on the right side Login unico

REGISTRATION GUIDE TO RESHELL SOFTWARE

EDITH. 60x60 LIGHT PANELS IT-EN

MANUALE DISPLAY REMOTO CALDAIE REMOTE DISPLAY MANUAL FOR BOILERS

TERMOREGOLAZIONE TEMPERATURE CONTROL

EVAPORATIVE COOLING PADS For breedings, greenhouses and industrial applications PANNELLI EVAPORATIVI RAFFRESCANTI

M A T R I X - M i c r o

Analisi e controllo ZODIAC

Solutions in motion.

HTP Metallic rotary vane mag drive pumps dry self-priming HTP Pompe rotative a palette e a trascinamento magnetico in metallo, autoadescanti a secco

Agente di rete NetMan 101/102 Plus SENSORI AMBIENTALI. Caratteristiche. Software e Accessori

PLASMA WELDING ROBOT SISTEMA ROBOTIZZATO PER SALDATURA AL PLASMA. PLASMA WELDING ROBOTIZED SYSTEM. AUTOMATION

Driver per LED EcoSystem

Cielo Stellato Super KITStarry Sky Super

plus expert. electrical boards for refrigerating installations. electrical boards for refrigerating installations

Sezione 1 / Section 1. Elementi d identità: il marchio Elements of identity: the logo

IPS VA DC/AC INVERTER. Specifiche tecniche Data sheet Vdc 230V 50 Hz

Codice Potenza Prezzo V 15 A 224, V 25 A 295, V 40 A 485, V 20 A 540,00

La proprietà intellettuale nella collaborazione tra Università e Impresa. Roberto Tiezzi - Technology Transfer Office

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

INFO ESTERNA Industry sector

Mod VIDEO GATEWAY A 4 CANALI 4 CHANNELS VIDEO GATEWAY. Sch./Ref.1067/450

BD1 (dual displacement / cilindrata doppia) BV1 (variable displacement / cilindrata variabile)

Mod. EASYCUP EASYCUP WITH LED PANEL: MINIMUM THICK!!!

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

24V DC ±10% W. Fluido Fluid. 15 Nl/min

full modular table All that has enabled us to succeed in achieving one of the most technologically advanced tables

SM1 - SM2 - SM MINI. La San Marco. Made in Italy

S line. For a Better World FLEXI LED. by STATUS

L automazione al servizio della gestione dell asset Dai carrelli automatici al monitoraggio dei consumi energetici. A cura di Speed Automazione Srl


M12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD MAIN OUT V JACK 50/60Hz 3 T1,25A. R mic. line AUX TUNER TAPE CD

CONTATTI MAGNETICI. C204 Contatto magnetico reed IMQ Reed magnetic contact, N.C. IMQ certified

DDS.682. C.F. partita Iva It capitale i. V ,00euro - telefono fax

Management software for remote and/or local monitoring networks

CCM - TORINO - VILLAGGIO PER BAMBINI - SOLOLO - ELENCO MATERIALE PER LA COSTRUZIONE DELL'IMPIANTO ELETTRICO

Transcript:

sistemi di disinfezioneuv UVdisinfection systems

I RAGGI UV-C UV-C RAYS La piccola porzione di spettro elettromagnetico avente lunghezze d onda comprese tra i 100 e i 400 nm (millesimi di micron) viene definita come intervallo della radiazione ultravioletta; gli UV-C fanno parte del sottointervallo caratterizzato dalle lunghezze d onda comprese tra i 100 e i 280 nm. Onde elettromagnetiche di diversa lunghezza d onda ed ampiezza inducono interazioni con la materia di varia natura; particolarmente interessante, grazie al suo spiccato potere germicida, è la radiazione UV-C con L = 254nm. L elevato potere germicida di questa lunghezza d onda va ricercato nel DNA e nel legame dei suoi componenti fondamentali (nucleotidi). Il DNA è una macromolecola presente in ogni organismo vivente nella quale risiedono tutte le informazioni necessarie per la vita e la riproduzione. L alterazione, indotta da radiazione UV-C, di alcuni legami chimici presenti tra i nucleotidi è in grado di cambiare l informazione contenuta e trasmessa dal DNA, tali modificazioni ne impediscono la normale attività il che conduce irreversibilmente alla morte cellulare. Per risultare efficace ai fini della sterilizzazione un onda elettromagnetica, oltre che essere di un certo tipo (L = 254nm), deve possedere anche un valore minimo d intensità per potere assicurare un dosaggio minimo all acqua. Questo dosaggio dipende molto dal tipo di contaminazione presente nell acqua ma in generale un impianto deve avere sempre un dosaggio superiore a 300 J/m 2. Un impianto di disinfezione UV correttamente dimensionato è in grado di impartire all acqua un dosaggio sufficiente ad abbattere la quasi totalità dei più comuni microrganismi presenti nell acqua. I raggi UV-C si producono con l ausilio di speciali lampade a fluorescenza contenenti vapori di mercurio, tali lampade sono costruite con quarzo purissimo (>99.99% SiO 2 ) trasparente alla luce UV-C che emettono in forma quasi monocromatica (>95% di L = 254nm). The small part of electro-magnetic spectrum having wave lengths included between 100 and 400 nm (thousandths of micron) is defined as the space of the ultra-violet irradiation. The UV-C are part of the subspace characterized by the wave lengths included between 100 and 280 nm. Electro-magnetic waves with different wave length and width induce interactions with the matter of different nature; the UV-C irradiation with L = 254nm is particularly interesting thanks to its marked germicidal power. The high germicidal power of this wave length must be sought in DNA and in the link of its fundamental components (nucleotids). DNA is a macromolecule present in all living organisms in which all information necessary for life and reproduction reside. The alteration, induced by the UV-C irradiation, of some chemical links present among nucleotids is able to change the information contained and conveyed by DNA, these alterations prevent its normal activity and this irreversibly leads to the cellular death. For being effective in the disinfection, an electro-magnetic wave, besides being of a certain kind (L = 254nm) it must possess also a minimum value of intensity to be able to ensure a minimum dose to water. A UV sterilizer, if correctly sized, is able to give water a dose sufficient for reducing almost all the commonest micro-organisms present in water. Normally a UV disinfection system must have a UV dose higher than 300 J/m 2. UV-C rays are produced with the help of special fluorescent lamps containing mercury fumes, these lamps are made of a very pure quartz (>99.99% SiO 2 ) transparent to the UV-C light which they emit in an almost monochromatic form (>95% of L = 254nm). PRESA CORRENTE A/C CON TRASFORMATORE A/C PLUG WITH TRANSFORMER CAMERA DI TRATTAMENTO TREATMENT CHAMBER TAPPO COPRICONTATTO CONNECTION COVER CAP GUAINA AL QUARZO QUARTZ COVERING LAMPADA UV UV LAMP BLOCCAGUAINA COVERING HOLDER SERIE DOMESTICA / DOMESTIC SERIES UV 300 AL 300 l/h UV 600 AL 600 l/h UV 1200 AL 2 1200 l/h UV 2800 AL 2 2800 l/h SERIE LCD / LCD SERIES UV 1200 LCD 1200 l/h UV 2800 LCD 2800 l/h UV 3600 LCD 3600 l/h UV 4500 LCD 4500 l/h UV 5100 LCD 5100 l/h UV 6000 LCD 6000 l/h UV 12000 LCD 12000 l/h SERIE RACK / RACK SERIES UV 20000 RACK 20000 l/h UV 80/4 RACK 30 m 3 /h UV 80/5 RACK 40 m 3 /h SERIE AM TC PLUS / AM TC PLUS SERIES UV AM 96 TC PLUS 96 m 3 /h UV AM 125 TC PLUS 125 m 3 /h SERIE TC / TC SERIES UV 400/3 TC 150 m 3 /h UV 400/4 TC 250 m 3 /h UV 400/5 TC 300 m 3 /h UV 400/6 TC 420 m 3 /h CONDIZIONI DI ESERCIZIO Temperatura ambiente... 5 45 C Temperatura acqua lavoro... 5 50 C Picco fino a... 70 C WORKING CONDITIONS Ambient temperature... 5 45 C Water working temperature... 5 50 C Peak until... 70 C 54 sistemi di disinfezione UV

DATA SHEET serie LCD - LCD series UV 3600-4500 LCD UV 4500 LCD UV 3600 LCD 230 BULLONE M4 per collegamento di terra BOLT M4 for earthing connection 28 (1 ) (1 ) BULLONE M4 per collegamento di terra BOLT M4 for earthing connection Lampada / Lamp 1x40 W Sfiato / Breather 1/8 OUT (1 1/2) øe 60.3 øe 60.3 816 925 øe 1 14.3 880 764 822 200 28 Scarico / Drain 1/2 IN (1 1/2) 58 QUADRO ELETTRICO ELECTRICAL PANEL 95 160 (UV 3600 LCD) 190 (UV 4500 LCD) 200 (UV 3600 LCD) 240 (UV 4500 LCD) UV 3600 LCD UV 3600 LCD - UV 4500 LCD CARATTERISTICHE CHARACTERISTICS portata max max flow rate 3600 l/h numero lampade number of lamps 1 x 40 W durata lampada lamp life-span 9000 ore / hours UV-C dose UV-C dose 300 J/m² consumo elettrico electrical absorption 40 W quadro elettrico electrical panel LCD / LCD PLUS (pag. 70) COLLETTORE UV CHAMBER materiale material AISI 304 - optional AISI 316L IN / OUT IN / OUT 1 1/2 M scarico e sfiato drain and breather 1/2-1/8 pressione di lavoro working pressure 9 bar UV 4500 LCD CARATTERISTICHE CHARACTERISTICS portata max max flow rate 4500 l/h numero lampade number of lamps 2 x 40 W durata lampade lamps life-span 9000 ore / hours UV-C dose UV-C dose 300 J/m² consumo elettrico electrical absorption 80 W quadro elettrico electrical panel LCD (pag. 70) COLLETTORE UV CHAMBER materiale material AISI 304 - optional AISI 316L IN / OUT IN / OUT 1 M pressione di lavoro working pressure 9 bar Dosaggio calcolato con trasmittanza del 99% a 1 cm - T 20 C - dopo 9000 ore Dose valid with transmittance 99% at 1 cm - T 20 C - after 9000 hours 58 sistemi di disinfezione UV

serie LCD - LCD series DATA SHEET UV 5100-6000 LCD UV 6000 LCD OUT (1 1/2) UV 5100 LCD BULLONE M4 per collegamento di terra BOLT M4 for earthing connection Lampada / Lamp 1x80 W Sfiato / Breather 1/8 OUT (1 1/2) 985 825 767 215 øe 114.3 SENSORE IRRAGGIAMENTO / IRRADIATION SENSOR øe 114.3 Scarico / Drain ø1/2 880 764 58 IN (1 1/2) 822 200 Scarico / Drain 1/2 58 IN (1 1/2) QUADRO ELETTRICO ELECTRICAL PANEL 95 UV 5100 LCD UV 5100 LCD - UV 6000 LCD 160 (UV 5100 LCD) 190 (UV 6000 LCD) 200 (UV 5100 LCD) 240 (UV 6000 LCD) CARATTERISTICHE CHARACTERISTICS portata max max flow rate 5100 l/h numero lampade number of lamps 1 x 80 W durata lampada lamp life-span 9000 ore / hours UV-C dose UV-C dose 300 J/m² consumo elettrico electrical absorption 80 W quadro elettrico electrical panel LCD / LCD PLUS (pag. 70) COLLETTORE UV CHAMBER materiale material AISI 304 - optional AISI 316L IN / OUT IN / OUT 1 1/2 M scarico e sfiato drain and breather 1/2-1/8 pressione di lavoro working pressure 9 bar UV 6000 LCD CARATTERISTICHE CHARACTERISTICS portata max max flow rate 6000 l/h numero lampade number of lamps 2 x 40 W durata lampade lamps life-span 9000 ore / hours UV-C dose UV-C dose 400 J/m² consumo elettrico electrical absorption 80 W quadro elettrico electrical panel LCD / LCD PLUS (pag. 70) COLLETTORE UV CHAMBER materiale material AISI 304 - optional AISI 316L IN / OUT IN / OUT 1 1/2 M scarico e sfiato drain and breather 1/2-1/8 pressione di lavoro working pressure 9 bar Dosaggio calcolato con trasmittanza del 99% a 1 cm - T 20 C - dopo 9000 ore Dose valid with transmittance 99% at 1 cm - T 20 C - after 9000 hours 59 UV disinfection systems

QUADRI ELETTRICI DATA SHEET Da sempre attenta alle innovazioni tecnologiche ed al costante mutamento del mercato, con la NUOVA SERIE DI SISTEMI UV-C, ATLAS FILTRI vuole proporre un prodotto innovativo e, come sempre, di qualità: I QUADRI ELETTRICI SERIE LCD, SERIE RACK e SERIE AM TC PLUS / TC. I nuovi quadri sono dotati di display LCD che visualizza le ore di lavoro delle lampade, le eventuali anomalie e, nella versione Plus, la temperatura e l irraggiamento. I nuovi quadri elettrici SERIE LCD, SERIE RACK e SERIE DS - di dimensioni contenute - sono stati studiati per facilitare le operazioni di installazione e manutenzione. ELECTRICAL PANELS Always careful about the technological innovations and the constant changes of the market, with the NEW SERIES OF UVC RAYS EQUIPMENTS, ATLAS FILTRI intends to propose an innovating and, as always, high quality product: THE LCD SERIES, RACK SERIES and AM TC PLUS / TC SERIES ELECTRICAL PANELS. The new electrical panels have been provided with a LCD display, which visualize the working hour of the lamps, the lamps faults, the irradiance and the temperature (Plus version). The new control panels of LCD SERIES, RACK SERIES and DS SERIES - with moderate dimensions - have been designed to facilitate the operations of installation and servicing. UV SERIE DOMESTICA - DOMESTIC SERIES SERIE INDUSTRIALE - INDUSTRIAL SERIES 300 600 1200 2800 1200 2800 3600 4500 5100 6000 12000 AL / AL 2 LCD (optional LCD PLUS) SERIE RACK - RACK SERIES 20000 80/4 80/5 RACK (optional RACK PLUS) SERIE AM TC PLUS / TC - AM TC PLUS / TC SERIES AM 96 AM 125 400/3 400/4 400/5 AM TC PLUS TC 400/6 69 UV disinfection systems

quadri elettrici - electrical panels LCD - LCD PLUS LCD alimentazione 230V - 50/60 Hz grado di protezione IP55 cavo di alimentazione 100 cm cavo di collegamento lampade 100 cm display LCD con controllo a microprocessore contaore led rosso segnalazione anomalia relè allarme a contatto pulito NA/NC relè allarme uscita 230 V NA/NC - 2 A max electrical alimentation 230V - 50/60 Hz protection degree IP55 power cable 100 cm cable lamps 100 cm LCD Display with microprocessor control count down hour-meter red led of anomaly alarm relay free contact NO/NC alarm relay 230 V NO/NC outlet - 2 A max LCD PLUS alimentazione 230V - 50/60 Hz grado di protezione IP55 cavo di alimentazione 100 cm cavo di collegamento lampade 100 cm display LCD con controllo a microprocessore contaore led rosso segnalazione anomalia relè allarme a contatto pulito NA/NC relè allarme uscita 230 V NA/NC - 2 A max display controllo irragiamento / temperatura spegnimento per alta temperatura collettore contaore resettabile con avviso fine vita lampada electrical alimentation 230V - 50/60 Hz protection degree IP55 power cable 100 cm cable lamps 100 cm LCD Display with microprocessor control count down hour-meter red led of anomaly alarm relay free contact NO/NC alarm relay 230 V NO/NC outlet - 2 A max display of Irradiation / temperature control shutdown for high temperature UV chamber resettable count down hour-meter with alarm for end lamp life 70 sistemi di disinfezione UV

quadri elettrici - electrical panels RACK - RACK PLUS RACK alimentazione 230V - 50/60 Hz grado di protezione IP55 cavo di alimentazione 150 cm cavo di collegamento lampade 250 cm display LCD con controllo a microprocessore contaore digitale resettabile segnalazione fine vita lampada led rosso segnalazione anomalia relè allarme a contatto pulito NA/NC relè allarme uscita 230 V NA/NC - 2 A max electrical alimentation 230V - 50/60 Hz protection degree IP55 power cable 150 cm cable lamps 250 cm LCD Display with microprocessor control resettable count down hour-meter with alarm for end lamp life alarm for end lamp life red led of anomaly alarm relay free contact NO/NC alarm relay 230 V NO/NC outlet - 2 A max RACK PLUS alimentazione 230V - 50/60 Hz grado di protezione IP55 cavo di alimentazione 150 cm cavo di collegamento lampade 250 cm display LCD con controllo a microprocessore contaore digitale resettabile segnalazione fine vita lampada led rosso segnalazione anomalia relè allarme a contatto pulito NA/NC relè allarme uscita 230 V NA/NC - 2 A max display controllo irragiamento / temperatura spegnimento per alta temperatura collettore electrical alimentation 230V - 50/60 Hz protection degree IP55 power cable 150 cm cable lamps 250 cm LCD Display with microprocessor control resettable count down hour-meter with alarm for end lamp life alarm for end lamp life red led of anomaly alarm relay free contact NO/NC alarm relay 230 V NO/NC outlet - 2 A max display of Irradiation / temperature control shutdown for high temperature UV chamber 71 UV disinfection systems

quadri elettrici - electrical panels AM TC PLUS/TC AM TC PLUS / TC grado di protezione IP54 touch-screen (65000 colori) display multilingua contaore (sistema e vita lampade) output digitali display controllo irraggiamento / temperatura remote on/off contatto 4/20 ma on/off timer datalog - eventi CAN, ethernet, USB, seriale (modbus, TCP/IP, CANopen) accesso remoto tramite app o web gate protection degree IP54 touch-screen (65000 colours) multilanguage display hour meters (system and lamp life) digital outputs display of Irradiation / temperature control remote on/off 4/20 ma contact timer on/off datalog - events CAN, ethernet, USB, seriale (modbus, TCP/IP, CANopen) remote access with app or web gate 72 sistemi di disinfezione UV