Valvole di blocco e valvole di sfioro Slam shut-off valves and Relief valves Serie MB-MS



Documenti analoghi
MADAS VALVOLE DI SFIORO TIPO MVS/1 MVS/1 RELIEF VALVES. fig. 1 VS03 DN 20 VS04 DN 25 VS05 DN 32 VS06 DN 40 VS07 DN 50. connections

RG/2M. max 0,5 bar P 1

elaboratore di segnale

Valvole automatiche on/off Automatic solenoid valves Series GSAVO-GSAV

Elettrovalvole Solenoid valves

MADAS VALVOLE DI SFIORO TIPO MVS/1 - MVSP/1 RELIEF VALVES TYPE MVS/1 - MVSP/1 MVS/1 - MVSP/1 II 2G - II 2D. pag MADAS s.r.l.

ELETTROVALVOLE N.A. 550 mbar. Misure ½ - ¾ ¼ - 1 ½ - 2 GAS ELECTRO-VALVES N.O. 550 mbar, dimensions ½ - ¾ ¼ - 1 ½ - 2

Regolatori di pressione alta pressione con blocco High pressure gas governor with shut off Serie ST4B-BM

Valvole / Valves 36 68

Regolatore di pressione di gas Gas pressure governor Series FS1B - ST1B

Safety valves. Valvole di sicurezza MVB/1 MAX MVB/1 MIN MVB/2 MIN MVS/1 - MVSP/1 SMO - SM. UPSO valve with automatic reset pag.

VALVOLE AD OTTURATORE COMANDO PNEUMATICO

R123 R123/34 brass. Brass pressure regulator, for compressed air, gas and liquid

Regolatore di pressione di gas Gas pressure governor Serie FGD-FGDR-FG1B

R Stainless steel AISI 316L high pressure regulator, suitable for compressed air, gas and liquid

Componenti per impianti a gasolio, olio combustibile e gas

REGOLATORI GAS A CHIUSURA TIPO RG/2M (DN DN

valvole 16 mm ad azionamento pneumatico

Sez./Section R Valvole per escavatori idraulici Hydraulic excavator Valves

Automatic air vent. Valvole di sfiato aria automatiche. Automatic air vents. Air vent Valmat. Air vent side discharge

RFU 1/8.2 RFUM 1/8 RFU 1/8.3 G1/8 G1/8. 2 mm 4.2 mm 120 Nl/min 450 Nl/min. 3.2 mm 4.2 mm 210 Nl/min 450 Nl/min bar MPa RFB 1/8 G1/8

valvole 18 mm ad azion. elettropneumatico

RG/2MBHZ.. RG/2MCSH..

valvole ad azionamento elettropneumatico

RG/2M. max 0,5 bar P 1

Riduttori di pressione

Elettrovalvole per gas a riarmo manuale NA NO Manually reset solenoid valves Serie MSVO - MSV

GRUPPI DI RIEMPIMENTO AUTOMATICI

R2034. Brass two stage high pressure regulator, suitable for laboratory use

elementi logici logic elements Ampia gamma Wide range Dimensioni ridotte Small dimensions

VALVOLA DI SFIORO PER MEDIA PRESSIONE IN AISI 316L

Valvole automatiche on/off Automatic solenoid valves Serie GSAVO-GSAV

QND. Posti presa CARATTERISTICHE

FLOW REGULATORS USER S MANUAL MANUALE D USO. SITECNA SRL Via G. Di Vittorio Peschiera Borromeo Milan Italy

MADE IN ITALY. Gas pressure regulator Regolatore di pressione per gas FG/FGB 100/ / / /510

VALVOLA DI SFIORO PER MEDIA PRESSIONE IN AISI 316L

POMPE EXCELSIOR - EXCELSIOR PUMPS

IDRJA VALVOLE DI RITEGNO IN ACCIAIO INOX STAMPATO CHECK VALVES FABRICATED FROM PRESSED STAINLESS STEEL

Diaphragm pressure reducing valves PN 40. Riduttori di pressione a membrana PN 40

IDRJA VALVOLE DI RITEGNO IN ACCIAIO INOX STAMPATO CHECK VALVES FABRICATED FROM PRESSED STAINLESS STEEL

VSF180. Valvole di sfioro ad alta sensibilità per bassa pressione in lega leggera idonee per aria compressa e gas

INSTALLAZIONE INSTALLATION

FILTROREGOLATORI DI RAPPORTO ARIA/GAS TIPO AG/RC AG/RC AIR/GAS RATIO CONTROL FILTER REGULATOR. attacchi connections

DP 2010 E depressore diretto G1/8 direct vacuum generator with G1/8 port

VALVOLE A FARFALLA IN PVC-U SERIE CLASSIC

valvole 16 mm ad azion. meccanico e manuale

V3V MD14 V3V MD12. Valvole a tre vie per aria compressa CARATTERISTICHE

Valvole elettromagnetiche serie VSB e VSA

FILTRO SERIE 10. Filtri per media pressione in ottone, idonei per aria compressa, gas e liquidi CARATTERISTICHE

mini-regolatore di pressione

FILTRO-REGOLATORI E REGOLATORI PER GAS DI CITTA, METANO, GPL

COLLETTORE SOLARE / SOLAR COLLECTOR

Serie 9000 RACCORDI A COMPRESSIONE - Serie Aggiornamento: 16 Maggio 2014 Updated May 16, 2014

NEWS 68. Valves and Solenoid valves Poppet system N776 Series

310F2. Filtri per media pressione in acciaio inossidabile AISI 316L, idonei per aria compressa, gas e liquidi CARATTERISTICHE

REGOLATORI GAS A CHIUSURA TIPO RG/2M (DN DN

Regolatore di pressione RB 1700 DN 3/4 e DN 1

DISCONNETTORE Articolo 102

AVP MD14 AVP MD12. Combined soft start/dump valve for compressed air FEATURES

Distributore Dosatore GPL&Metano serie JMU JMU serie : LPG and NGV Gas Dosage Unit

Regolatori di pressione alta pressione con blocco High pressure gas governor with shut off Serie ST4B-BM

R1200. Brass high pressure regulator, for compressed air, gas and liquids

RG/2MC. max 1 bar P 1

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

COLLETTORE SOLARE / SOLAR COLLECTOR DOCCE E ACQUA SANITARIA / SHOWERS AND SANITY WATER

SWING check valve. Istallazione - Installation

valvole VDMA 18 mm azionamento pneumatico

SERIE M6 con molla SERIE 06 senza molla Valvola di ritegno a clapet Wafer

Filtri gas / Gas filters

mini-regolatore di pressione con manometro

R190. Regolatore di pressione ad alta sensibilità in alluminio

Valvola d'intercettazione del combustibile Serie VIC-A

ELETTROVALVOLE E RILEVATORI SICUREZZA GAS GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES CATALOGO TECNICO TECHNICAL CATALOGUE

R160. Regolatore di pressione ad alta sensibilità

Inlet Pressure Required Outlet Pressure. Fluid / Media. Connection (flange / thread) Flow rate (or use) Inlet pressure Pressione di entrata.

valvole 16 mm ad azion. meccanico e manuale

VPB. Valvole di blocco pneumatiche CARATTERISTICHE. Valvole di blocco in ottone o alluminio per pressioni fino a 50 bar.

FRG/2MBH... - FRG-RG/2MCSH P 2

Adattatori di filetto. Thread adaptors PER INSTALLAZIONI IN INTERNO ED ESTERNO FOR INDOOR AND OUTDOOR APPLICATIONS. Adattatori MASCHIO-FEMMINA

R4121. Regolatore per media pressione, in alluminio con interni in acciaio inossidabile AISI 316L idoneo per aria compressa, gas e liquidi

F14MD F18MD. Modular filters, suitable for compressed air FEATURES. Filter for inlet pressure up to 30 bar (435 psi).

310R3. Regolatore di pressione ad alta sensibilità in acciaio INOX AISI 316L

R180. Regolatore di pressione ad alta sensibilità in alluminio

Automatic airvents HIGH CAPACITY ROME

MANOMETRI/PRESSURE GAUGES IDROMETRI/WATER GAUGES

210R2. Regolatori in alluminio serie 10 per media pressione, idonei per aria compressa e gas.

mini-regolatore di pressione con manometro

VSF130 VSF130/2. Valvole di sfioro per media pressione in ottone idonee per aria compressa, gas e liquidi

GIUNTI DI SMONTAGGIO E COLLEGAMENTO dismantling joint - connection joint

Preriscaldatori CARATTERISTICHE. Preriscaldatore per bombole di CO2 e rampe ID Insert Deal.

210R2. Aluminium pressure regulator series 10, suitable for compressed air and gases.

0068-GAR-B TECNOCONTROL Srl Via Miglioli, SEGRATE (MI)

Serie Ekoflux L. -Smart, Be-Brandoni. Valvola di intercettazione e regolazione flangiata Shut-off and regulation flanged valve DOWNLOAD DATASHEET

main components in overpressure valves for electric water heaters _ elementi costitutivi nelle valvole di sicurezza per scaldacqua elettrici

VSF3300. Valvole di sfioro per alta pressione in acciaio inossidabile 316L idonee per aria compressa, gas e liquidi

Transcript:

Valvole di blocco e valvole di sfioro Slam shut-off valves and Relief valves Serie MB-MS Caratteristiche principali La valvole di blocco e di sfioro sono prescritte in accordo con la normativa EN76- ogni qualvolta la pressione in ingresso al regolatore è superiore a quella massima ammissibile dalle valvole a valle dello stesso regolatore. Main features Safety shut off and relief valves are prescribed in accordance with EN76- for all gas governing installation on wich the valves downstream of the gas governor are not resistant to the upstream pressure.

VALVOLE DI BLOCCO / SLAM SHUT-OFF VLVES SERIE MB DATI TECNICI Attacchi :... filettati UNI ISO 7-1; flangiati EN 109- Max pressione entrata :...1 bar (MB); 6 bar (MB/6B) Temperature limite ambiente :... -10 +60 C Campo pressioni di intervento :... molla blu: 0 10 mbar... molla neutra: 80 550 mbar Massima temperatura superficiale :... 60 C Combustibili : gas delle tre famiglie (gas città, metano, GPL); gas non aggressivi. Materiali : corpo valvola e coperchio in alluminio; molle e pistone di comando in acciaio inox; gomma di tenuta ed o-ring in NBR; altri particolari in ottone, alluminio ed acciaio zincato. TECHNICAL SPECIFICATIONS Connection :.. threaded UNI ISO 7-1; flanged EN 109- Maximum inlet pressure :... 1 bar (MB); 6 bar (MB/6B) Ambient temperature :... -10 C +60 C Response pressure :... blue spring: 0 10 mbar... neutral spring: 80 550 mbar Max surface temperature :... 60 C Fuel : all three families of gas (city gas, methane, LPG); non aggressive gases. Material : aluminium valve's body and cover; stainless steel springs and control piston; NBR rubber gasket and O-ring; other part are of brass, aluminium and galvanised steel. GENERALITÀ Le valvole di blocco di massima pressione della serie MB e MB/6B sono normalmente aperte. L'apertura viene mantenuta grazie ad un meccanismo che interviene automaticamente al riarmo della valvola. Se il polmone di blocco rileva una pressione in ingresso superiore al valore di taratura si sgancia il dispositivo di chiusura che blocca il flusso del gas. GENERAL INFORMATION The maximum pressure slam shut off valves in the MB and MB/6B series are safety devices kept open under normal work conditions thanks to an automatic mechanism triggered upon manually rearming. If the shut off plenum detects an inlet pressure greater than the calibration value, it releases the closure device which stops the gas flow. INSTALLAZIONE Le valvole di blocco di massima pressione MB - MB/6B sono conformi alla Direttiva 9/9/CE (Direttiva ATEX) come apparecchio del gruppo II categoria G e come apparecchio del gruppo II, categoria D; come tale sono idonee ad essere installate nelle zone 1 e 1 e a maggior ragione nelle zone e come classificate nell'allegato I della Direttiva 99/9/CE. Le valvole di blocco in oggetto non è invece idonea per l'utilizzo nelle zone 0 e 0 come definite nella Direttiva 99/9/CE. Per determinare la qualifica e l'estensione delle zone pericolose si veda la norma EN 60079-10. La valvola di blocco, se installata e manutenzionata nel rispetto delle condizioni e delle istruzioni riportate nell'allegato documento tecnico, non costituisce fonte di pericoli specifici. In particolare l'apparecchio in condizioni di funzionamento normale non costituisce fonte di emissione nell'atmosfera di sostanze infiammabili tali da dare origine ad un'atmosfera esplosiva. Il polmone di blocco è dotato di una membrana di lavoro e una di sicurezza; in caso di rottura della membrana di lavoro quella di sicurezza garantisce una fuoriuscita di gas con portata non superiore ai 0 dm /h. Solo nel caso di contemporanea rottura delle due membrane abbiamo una emissione di atmosfera esplosiva di grado continuo e pertanto capace di dare origine ad una zona pericolosa 0. Nel caso la valvola venga installata in un luogo non presidiato o con carenza di areazione, occorre prendere tutte le precauzioni al fine di evitare che la valvola stessa sia causa di origine di una zona 0. Ad esempio si potrebbe portare all'esterno lo sfiato del polmone di blocco tramite un tubo di rame da collegare al foro filettato G1/8" togliendo il tappo antipolvere in ottone. La posizione di montaggio è indifferente; su tubazioni orizzontali evitare di posizionare il pomolo di riarmo della valvola rivolto verso il basso. INSTALLATION The maximum pressure slam shut off valves MB - MB/6B conform to Directive 9/9/EC (ATEX) in group II category G and in group II, category D; as such they are suitable for installation in zones 1 and 1 and, even more so, in zones and as classified in enclosure I of Directive 99/9/EC. The shut off valves described here are not suitable for use in zones 0 and 0 as defined in Directive 99/9/EC. To determine the qualification and extension of the hazardous zones, see standard EN 60079-10. If installed and maintained as per the conditions and instructions given in the enclosed technical manual, the shut off valve is not a source of specific danger. In particular, under normal operating conditions, the device does not emit inflammable substances such as to generate an explosive atmosphere. The shut off plenum has a work membrane and a safety membrane; if the work membrane breaks, the safety membrane guarantees gas emission with flow rate no higher than 0 dm /h. A continuous explosive atmosphere able to generate a hazardous zone 0 is emitted solely in the event both membranes break simultaneously. In the event the valve is installed in an unmanned or poorly aired location, all the necessary precautions should be taken to prevent the valve from being the cause of a zone 0. For example, the shut off plenum breather may be routed outside via a copper pipe connected to the threaded hole G1/8" by removing the dustproof brass cap. The assembly position is indifferent; on horizontal piping, do not position the valve rearming knob facing down.

VALVOLE DI BLOCCO / SLAM SHUT-OFF VLVES SERIE MB Si consiglia il rispetto delle seguenti prescrizioni : evitare di montare la valvola facendo leva sul cannotto; accertarsi che le tubazioni siano ben allineate e che internamente non siano ostruite o sporche; rispettare la direzione del flusso secondo la freccia impressa sul corpo della valvola; verificare che tutti i parametri di pressione, tensione, temperatura ecc.. siano rispettati; evitare di installare a contatto con pareti intonacate; non impedire o in qualche modo ostacolare la corsa del pomello di riarmo, in quanto la chiusura potrebbe non essere garantita; montare un filtro idoneo per gas a monte della valvola. La valvola di blocco va installata a monte del regolatore di pressione. La presa di impulso (foro filettato G1/8") posta sul polmone va collegata tramite tubo di rame, con diametro di passaggio non inferiore a mm, a valle del regolatore ad una distanza dallo stesso pari normalmente a 5 volte il diametro della tubazione. TUTTE LE OPERAZIONI DI ISTALLAZIONE, RIARMO, TARATURA E MANUTENZIONE, DEVONO ESSERE ESEGUITE ESCLUSIVAMENTE DA PERSONALE QUALIFICATO. The following guidelines should be followed : do not lever on the sleeve when assembling the valve; ensure that the piping is well aligned and that there are no obstructions or dirt inside; observe the flow direction as shown by the arrow printed on the valve body; check that all pressure, voltage, temperature etc. parameters are complied with; do not install the valve in contact with plastered walls; do not hinder or in any way obstruct the stroke of the rearming knob, as closure may not be guaranteed; fit a suitable gas upstream of the valve. The shut off valve should be installed upstream of the pressure regulator. The impulse outlet (threaded hole G1/8") on the plenum should be connected via copper pipe, with diameter no less than mm, downstream of the regulator at a distance from the regulator of 5 times the diameter of the pipe. ALL INSTALLATION, REARMING, CALIBRATION AND MAINTENANCE OPERATIONS MUST BE CARRIED OUT SOLELY BY QUALIFIED PERSONNEL. In conformità alla Direttiva 97//CE (previsto per i modelli 6 bar) According to the 97//CE regulation (foreseen for the 6 bar models) Omologazioni per altri paesi disponibili. Other countries homologations available. Tipo/Type MB5 Tipo/Type MB65

VALVOLE DI BLOCCO / SLAM SHUT-OFF VLVES SERIE MB E A F MADE IN TALY G 1/8 I D B C A MADE IN TALY I Dimensioni d ingombro/overall dimensions (mm) E F G 1/8 D B C *) Attacco G1/8" da collegare a valle del regolatore. G1/8" connection to connect downstream the regulator. Mod. MB15 MB0 MB5 MB MB0 MB50 MB65 MB80 MB100 MB15 MB150 MB15/6B MB0/6B MB5/6B MB/6B MB0/6B MB50/6B MB65/6B MB80/6B MB100/6B MB15/6B MB150/6B A Rp 1/ Rp / Rp 1 Rp 1 1/ Rp 1 1/ Rp DN 65 DN 80 DN 100 DN 15 DN 150 B 5 5 5 5 5 6 9 100 110 15 1 C 175 175 175 175 175 175 197 197 197 180 180 D 76 96 96 15 15 17 00 00 60 80 80 E 15 5 5 1 1 9 100 100 105 170 170 F 10 10 10 170 170 170 0 0 0 70 70

VALVOLE DI BLOCCO / SLAM SHUT-OFF VLVES SERIE MB Diagramma portate - Perdite di carico/diagram of flow rates - Pressure drops 1/ / 1 1.1/ 1.1/ DN65 DN80 DN100 DN15 DN150 5 50 0 0 0 15 10 7 p (mbar) 5 1 1 5 6 7 8 9 10 15 0 0 0 50 70 100 150 00 00 00 500 800 1000 1500 000 5 6 7 8 9 10 15 0 0 0 50 70 100 150 00 00 00 500 800 1000 5 6 7 8 9 10 15 0 0 0 50 70 100 150 00 00 00 500 800 1000 7 8 9 10 15 0 0 0 50 70 100 150 00 00 00 500 700 1000 1500 000 Q (m /h) 1 Metano - Methane dv: 0,6 Aria - Air dv: 1 Propano - Propane dv: 1,56 Gas città - Town gas dv: 0,5 Esempio d installazione / Installation Plan 1 5 Giunto antivibrante - Compensator joint. Filtro - Filter. Valvola di blocco - Slam shut off valve (MB). Regolatore di pressione - Pressure governor. Valvola di sfioro - Relief valve (MS). 5 1

VALVOLE DI SFIORO / RELIEF VALVES SERIE MS 6 DATI TECNICI Attacchi :... filettati UNI ISO 7-1 Max pressione entrata :... 6 bar Temperature limite ambiente :... -10 + 60 C Pressioni di taratura :... molla rossa 0 10 mbar... molla blu 80 600 mbar Combustibili : gas delle tre famiglie (gas città, metano, GPL); gas non aggressivi. Materiali : corpo valvola e coperchio in alluminio; molle in acciaio inox; pistone di comando in acciaio; gomma di tenuta ed O-ring in NBR; altri particolari in ottone, allumino ed acciaio zincato. TECHNICAL SPECIFICATIONS Connection :... threaded UNI ISO 7-1 Maximum inlet pressure :... 6 bar Ambient temperature :... -10 + 60 C Response pressure :... red spring 0 10 mbar... blue spring 80 600 mbar Fuel : all three families of gas (city gas, methane, LPG); non-aggressive gases. Material : aluminium valve's body and cover; stainless steel springs; steel control piston; NBR rubber gasket and O-ring; other parts made of brass, aluminium and galvanised steel. GENERALITÀ Le valvole di sfioro della serie MS sono normalmente chiuse. L'apertura avviene solamente se la pressione in ingresso supera il valore di taratura, la chiusura avviene automaticamente quando la pressione ridiscende sotto il valore di taratura. GENERAL INFORMATION The relief valves in the MS series are normally closed. The valves open solely is the inlet pressure is greater than the calibration value. The valves close automatically when the pressure returns to below the calibration value. INSTALLAZIONE Le valvole di sfioro della serie MS sono conformi alla Direttiva 9/9/CE (Direttiva ATEX) come apparecchio del gruppo II categoria G e come apparecchio del gruppo II categoria D; come tale sono idonee ad essere installate nelle zone 1 e 1 e, a maggior ragione, nelle zone e come classificate nell'allegato I della Direttiva 99/9/CE. Le valvole di sfioro in oggetto non è invece idonea per l'utilizzo nelle zone 0 e 0 come definite nella Direttiva 99/9/CE. Per determinare la qualifica e l'estensione delle zone pericolose si veda la norma EN 60079-10. La valvola di sfioro, se installata e manutenzionata nel rispetto delle condizioni e delle istruzioni riportate nell'allegato documento tecnico, non costituisce fonte di pericoli specifici. In particolare l'apparecchio in condizioni di funzionamento normale prevede l'emissione nell'atmosfera di sostanze infiammabili tali da dare origine ad un'atmosfera esplosiva solo occasionalmente. La valvola di sfioro è dotata di una membrana di lavoro e una di sicurezza; in caso di rottura della membrana di lavoro, quella di sicurezza garantisce una fuoriuscita di gas con portata non superiore ai 0 dm /h. Solo nel caso di contemporanea rottura delle due membrane abbiamo una emissione di atmosfera esplosiva di grado continuo e pertanto capace di dare origine ad una zona pericolosa 0. Nel caso la valvola sia installata in un luogo non presidiato o con carenza di areazione, occorre prendere tutte le precauzioni al fine di evitare che la valvola stessa sia causa di origine di una zona 0. Ad esempio si potrebbe portare all'esterno lo sfiato tramite un tubo di rame da collegare al foro filettato G1/8" togliendo il tappo antipolvere in ottone. La posizione di montaggio è indifferente; su tubazioni orizzontali si raccomanda di tenere il cannotto della valvola rivolto verso l'alto. INSTALLATION The relief valves in the MS series conform to Directive 9/9/EC (ATEX) in group II category G and in group II category D; as such they are suitable for installation in zones 1 and 1 and, even more so, in zones and as classified in enclosure I of Directive 99/9/EC. The relief valves described here are not suitable for use in zones 0 and 0 as defined in Directive 99/9/EC. To determine the qualification and extension of the hazardous zones, see standard EN 60079-10. If installed and maintained as per the conditions and instructions given in the enclosed technical manual, the relief valve is not a source of specific danger. In particular, under normal operating conditions, the device only rarely emits inflammable substances such as to generate an explosive atmosphere. The relief valve has a work membrane and a safety membrane; if the work membrane breaks, the safety membrane guarantees gas emission with flow rate no higher than 0 dm /h. A continuous explosive atmosphere able to generate a hazardous zone 0 is emitted solely in the event both membranes break simultaneously. In the event the valve is installed in an unmanned or poorly aired location, all the necessary precautions should be taken to prevent the valve from being the cause of a zone 0. For example, the breather may be routed outside via a copper pipe connected to the threaded hole G1/8" by removing the dustproof brass cap. The valve may be assembled in a variety of positions; on horizontal piping it is advisable to keep the valve sleeve facing upwards.

VALVOLE DI SFIORO / RELIEF VALVES SERIE MS Si consiglia il rispetto delle seguenti prescrizioni : evitare di montare la valvola facendo leva sul cannotto; accertarsi che le tubazioni siano ben allineate e che internamente non siano ostruite o sporche; rispettare la direzione del flusso secondo la freccia impressa sul corpo della valvola; verificare che tutti i parametri di pressione, temperatura ecc.. siano rispettati; evitare di installare a contatto con pareti intonacate. La valvola di sfioro va installata a valle del regolatore di pressione. TUTTE LE OPERAZIONI DI ISTALLAZIONE, TARATURA E MANUTENZIONE, DEVONO ESSERE ESEGUITE ESCLUSIVAMENTE DA PERSONALE QUALIFICATO. The following guidelines should be followed : do not lever on the sleeve when assembling the valve; ensure that the piping is well aligned and that there are no obstructions or dirt inside; observe the flow direction as shown by the arrow printed on the valve body; check that all pressure, temperature etc. parameters are complied with; do not install the valve in contact with plastered walls. The relief valve should be installed upstream of the pressure regulator. ALL INSTALLATION, CALIBRATION AND MAINTENANCE OPERATIONS MUST BE CARRIED OUT SOLELY BY QUALIFIED PERSONNEL. 7 In conformità alla Direttiva 97//CE (previsto per i modelli 6 bar) According to the 97//CE regulation (foreseen for the 6 bar models) Omologazioni per altri paesi disponibili. Other countries homologations available. Dimensioni d ingombro/overall dimensions Tipo/Type MS A B C D E Tipo/Type A B C D E MS0 Rp /" 5 15 170 96 MS5 Rp 1" 5 15 170 96 Le descrizioni e le fotografie contenute nel presente, si intendono fornite a semplice titolo informativo e non impegnativo. Giuliani Anello si riserva il diritto di apportare, senza alcun preavviso, qualsiasi modifica tecnica ed estetica ai propri prodotti. The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Giuliani Anello reserves the right to carry out any technical and design improvements to its products without prior notice.

Re-order no. 6-0065-I-UK-IT/-0-1-Rev. A Division of Watts Water Technologies Inc. Watts Industries Italia S.r.l. Via F.lli Bandiera, 8-0 Cento (FE) - Italy Phone +9 051.901.1 - Fax +9 051.901.05 e-mail: giulianianello@giulianianello.it - www.giulianianello.com