C1G 14/18/22. Pompe a pistoni assiali a cilindrata variabile Variable-displacement axial piston pumps

Documenti analoghi
C3 46/50/64. Pompe a pistoni assiali a cilindrata variabile Variable-displacement axial piston pumps

INFORMAZIONI GENERALI GENERAL INFORMATION

MOTORI AD INGRANAGGI GEAR MOTORS

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC. Pompa a pistoni assiali per circuito aperto versione per Fan Drive

POMPA A MANO MODULARE DI EMERGENZA

H2V 2PI PROCEDURE DI PROVA TESTING PROCEDURE

POMPA PNEUMOIDRAULICA PNEUMOHYDRAULIC PUMP VERSIONE PER OLIO E PER ACQUA OIL AND WATER WORKING APPLICATION

pressostati pressure switches

BD1 (dual displacement / cilindrata doppia) BV1 (variable displacement / cilindrata variabile)

SH5V POMPA A PISTONI ASSIALI A CILINDRATA VARIABILE PER CIRCUITO APERTO VARIABLE DISPLACEMET AXIAL PISTON PUMP FOR OPEN CIRCUIT E/1 COD.

NEWS 68. Valves and Solenoid valves Poppet system N776 Series

24V DC ±10% W. Fluido Fluid. 15 Nl/min

Serie BL diametro 28 mm con elettronica integrata per regolazione velocità. 28 mm diameter, BL series + integrated speed controller

HAND PUMPS FLN 20 E-4 FPN 50 E-5 CSN12 - CSN25 - CSN45 E-6 CSIN12 - CSIN25 - CSIN45 E-8 IS6 - IS7 E-10 E-1

MOON. Misura (cm) Finitura Pannelli. Peso (kg) Volume. Volume (dm³) Articolo Article. Weight. Dimension. Panels Finishing VTR

HTM SS 316 PUMPS Metallic mag drive centrifugal pumps POMPE HTM SS 316

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES

GS6A GS6A SERIES TECHNICAL CATALOGUE CATALOGO TECNICO SERIE GS6A Potenza di picco (²) Peso approssimativo unità Capacità olio motore

24V DC ±10% W. Fluido Fluid. 15 Nl/min

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

DEVIATORI DI FLUSSO DIVERTER VALVES

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

NDCMB NDCMB MOTORIDUTTORI C.C. AD ASSI ORTOGONALI RARE EARTH D.C. BEVEL HELICAL GEARMOTORS

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/ Fax 057/ internet:

quick guide guida rapida J.touch hydromassage bath remote control telecomando per vasche idromassaggio

ERGON. ARATRI SEMIPORTATI REVERSIBILI MONORUOTA SEMI-MOUNTED REVERSIBLE PLOUGHS-single wheel

HPP-HPF PUMPS POMPE HPP-HPF

VALVOLE DI MASSIMA PRESSIONE RELIEF VALVES

S5AV POMPA A PISTONI ASSIALI A CILINDRATA VARIABILE PER CIRCUITO APERTO VARIABLE DISPLACEMET AXIAL PISTON PUMP FOR OPEN CIRCUIT G/1 COD.

Macchine ad Impatto Impact machines

H1CR MOTORI INTEGRATI A CILINDRATA FISSA PER RIDUTTORI PLUG-IN FIXED DISPLACEMENT MOTORS FOR GEARBOX I/1 COD A10

valvole ad azionamento meccanico mechanically actuated valves

Joystick Idraulici Biasse Serie JH4 03.JH4-0910

P/N DESCRIPTION QUANTITY

MONITORE A COMANDI ELETTRICI Mod. FI-EMW ELECTRIC REMOTE CONTROLLED MONITOR Mod. FI-EMW

ACCESSORI PER POMPE E MOTORI IDRAULICI HYDRAULIC PUMPS AND MOTORS ACCESSORIES

Alimentatori per LED di segnalazione (MINILED) Power supply units for Signal LEDs (MINILED)

Pagg. 1 3 Pages 1 3. Pag. 4 Page 4. Pag. 5 Page 5. Pag. 10 Page 10. Pag. 15 Page 15. Pagg. 16, 17 Pages 16, 17

GAZZERA SRL HYDRAULIC POWER PACK. w w w. g a z z e r a i t a l y. c o m i n f g a z z e r a i t a l y. c o m. h y d r a u l i c d i v i s i o n

CURVATURA - BENDING C50 ES

WEIGHING SYSTEMS SISTEMI DI PESATURA

Posizione di montaggio. Fluido idraulico. Temperatura di esercizio. Filtraggio livello di contaminazione consigliato =< 18/13 secondo DIN ISO 4406

TIAN XIA 500 fluo. Product presentation

BILANCIAMENTO / BALANCING

Fluido idraulico Fluid. Viscosità cinematica consigliata Kinematic viscosity suggested

Motore/Pompa idraulica. Serie F11/F12 Cilindrata fissa

filtro separatore G1 G1 filter-water-separator

U/D (SELEZIONE UP/DOWN) U/D (UP/DOWN SELECTION )

SH11C POMPE A CILINDRATA FISSA FIXED DISPLACEMENT PUMPS COD A01 B/1

CCS2 Contamination Control System

SERIE HPB BAR SERIES. Filtri alta pressione High pressure filters. Filtri - Filters 10

M O V I M E N T I M O V E M E N T S

Athena. the perfect dosing

MAV4211SH SCHEDA ELETTRONICA DI CONTROLLO ELECTRONIC CONTROL CARD

SERIE APM-110 BAR SERIES. Filtri in linea a media pressione In line filter medium pressure. Filtri - Filters 09

QUESTO DOCUMENTO E DA INTENDERSI UN APPENDICE AL MANUALE DI INSTALLAZIONE USO E MANUTENZIONE RIDUTTORI SERIE RE GB PAGINA 1 DI 10

M12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD VOLUME BASS HIGH. MAINOUT V JACK 50/60 Hz 3 T1,25A. R mic.

CI ADV FP 12/02 T3000 V25O FLUID POWER. Technical Catalogue V250

MADE IN ITALY. Gas pressure regulator Regolatore di pressione per gas FG/FGB 100/ / / /510

gruppo trattamento aria FR+L G1/4

VALVOLE CORPO FILETTATO CON OTTURATORE BREVETTATO VALVES WITH THREADED POPPET BODY PATENTED SYSTEM

Regolatori idraulici di velocità Hydraulic speed regulators SERIE 330

gruppo trattamento aria FR+L G1/4

H1CR MOTORI INTEGRATI A CILINDRATA FISSA PER RIDUTTORI PLUG-IN FIXED DISPLACEMENT MOTORS FOR GEARBOX E/1 COD A12

Informazioni tecniche sui sistemi di regolazione per pompe a pistoni assiali a cilindrata variabile della Serie H1V Series Technical information on

INNESTO DELLE LAMELLE A TELAIO CHIUSO CON COMPENSAZIONE RAPIDA COUPLING OF SLATS IN CLOSED FRAME WITH RAPID ADJUSTMENT

M12 X-4. Mixer Preamplifier MASTER 5 AUX TUNER TAPE CD MAIN OUT V JACK 50/60Hz 3 T1,25A. R mic. line AUX TUNER TAPE CD

group STRUMENTO CANVIEW 3+ CANVIEW 3+ INSTRUMENT CLUSTER CAN J1939 ISOBUS - ISO11783 VT3 SOFTWARE DEVELOPMENT TOOLS IEC 61131

HCV H1C H1CR H2V H2VR H1V INDICE CONTENTS. Valvole di taglio Cut off valves. Valvole di scambio Flushing valves

filtro separatore G1/4 G1/4 filter-water-separator

Freni idraulici multidisco serie F Hydraulic Multidisc Brakes F Series

Addolcitori Softeners

SERRATURE A DOPPIA MAPPA PER PORTE BLINDATE

Sistemi di connessione Distribox e Spiderbox

ECMG ECMG. Motoriduttori C.C. ad ingranaggi cilindrici Permanent Magnets D.C. Helical GearmotorS

BDMPro Positioning Frame

SDM081. Distributore monoblocco da 1a6sezioniperpiccoleportate 1 to 6 sections monoblock valve for low flow applications D D

ultra_tech : Pump with filter for

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

Chiudiporta nascosto a camma 900 Concealed cam door closer 900. ASSA ABLOY, the global leader in door opening solutions

MOTORI ORBITALI/HYDRAULIC MOTORS

PERFORAZIONE DRILLING DEMOLIZIONE DEMOLITION. S LITTA da PERFORAZIONE in LEGA di ALLUMINIO ALUMINIUM DRILL MAST

Componenti per impianti a gasolio, olio combustibile e gas

Quick start manual Manuale rapido. Version 3.0

Serie a sfera Ball valve series ARNS

SERIE - SERIES GENERALITA / FEATURES MATERIALI / MATERIALS CATALOGO GENERALE GENERAL CATALOGUE 2014

SERIE SPIN-ON SERIES Filtri in linea Filters. Filtri - Filters 08

POWER SUPPLY 10mA 1A POWER SUPPLY 2,5 15A

COMPONENTI PER IMPIANTI IDRAULICI/ RISCALDAMENTO COMPONENTS FOR PLUMBING AND HEATING SYSTEM

Informazione Tecnica Technical Information TI DVS14 Nuovo Distributore Componibile New Sectional Valve HYDRONEWS

Trasmettitore di pressione per applicazioni industriali generiche Modello A-10

IPS VA DC/AC INVERTER. Specifiche tecniche Data sheet Vdc 230V 50 Hz

Pentair ensures that all of its pumps (see Annex) affected by the above mentioned Regulation meet the 0,1 MEI rating.

Literature Metering Pumps

TNCguide OEM Informativa sull introduzione di documentazione aggiuntiva nella TNCguide

PRODUCT DATA SHEET. Copernico 500 sospensione - Red TECHNICAL DATA SHEET. Features. Dimensions OPTICS DIMENSIONS LAMP LAMPS INCLUDED ELECTRICAL

V -TECH V-TECH V -TECH. La gamma delle centraline V 0 -Tech V-Tech e. V 3 -Tech è stata pensata per soddisfare ogni

Serie Cylinders. Serie Mini Inox. Serie CA - CAF. Serie A95 Pag Serie Mini. Serie B. Serie Q. Serie X. Serie NHA. Serie W Pag

/ < " DI MANAGEMENT C RTI ICA ISTEM )3/ )3/ ä - "

DZAK-2 USE AND MAINTENANCE

Transcript:

Pompe a pistoni assiali a cilindrata variabile Variable-displacement axial piston pumps C1G 14/18/22 Per circuito chiuso MEDIA PRESSIONE - For closed circuits MEDIUM DUTY

CODICI DI ORDINAZIONE ORDERING CODE C1G 14/18/22 CODICE DEL PRODOTTO MODEL CODE 1 - SERIE / SERIES 10: Omettere se non richiesto 10: Omit if not required C1 Pompa a pistoni assiali a cilindrata variabile per circuito chiuso MEDIA PRESSIONE Variable displacement axial piston pump for closed circuit MEDIUM PRESSURE 2 CILINDRATA / DISPLACEMENT 14 18 22 Cilindrata 14 cm 3 /giro Displacement 0.85 in 3 /rev Cilindrata 18 cm 3 /giro Displacement 1.09 in 3 /rev Cilindrata 22cm 3 /giro Displacement 1.33 in 3 /rev 2A LIMITAZIONE CILINDRATA / DISPLACEMENT LIMITATION 3 - REGOLATORI / CONTROLS IND EI2 EI4 IRX LRX LNX LWX E22 E24 ER2 ER4 EP2 EP4 EH2 EH4 Idraulico proporzionale non retroazionato Hydraulic proportional without feed-back Elettrico ad impulsi 12V Electric impulse 12V Elettrico ad impulsi 24V Electric impulse 24V Idraulico proporzionale retroazionato Hydraulic proportional with feed-back Manuale a leva retroazionato Manual lever with feed-back Manuale con azzeratore Manual with zeroing Manuale senza azzeratore Manual without zeroing Elettrico 2 posizioni ON-OFF 12V Electric two position ON-OFF 12V Elettrico 2 posizioni ON-OFF 24V Electric two position ON-OFF 24V Elettrico proporzionale retroazionato 12V Electric proportional with feed-back 12V Elettrico proporzionale retroazionato 24V Electric proportional with feed-back 24V Elettrico proporzionale non retroazionato 12V Electric proportional without feed-back 12V Elettrico proporzionale non retroazionato 24V Electric proportional without feed-back 24V Elettrico proporzionale retroazionato 12V + Idraulico proporzionale retroazionato Electric proportional with feed-back 12V + Hydraulic proportional with feed-back Elettrico proporzionale retroazionato 24V + Idraulico proporzionale retroazionato Electric proportional with feed-back 24V + Hydraulic proportional with feed-back 51

CODICI DI ORDINAZIONE ORDERING CODE C1G 14/18/22 4 PREDISPOSIZIONI / THROUGHT DRIVE ESTREMITÀ ALBERO SHAFT END 1 2 3 4 5 6 7 8 9 Nessuna Predisposizione con pompa sovralimentazione Without through drive with charge pump Nessuna predisposizione senza pompa sovralimentazione Without through drive without charge pump SAE A = Z9 16/32 DP con pompa sovralimentazione SAE A = Z9 16/32 DP with charge pump SAE A = Z9 16/32 DP senza pompa sovralimentazione SAE A = Z9 16/32 DP without charge pump Tandem (Versione Corta) assemblata Pump combination (Short Version) Bosch GR1 con pompa sovralimentazione Bosch GR1 with charge pump Bosch GR2 con pompa sovralimentazione Bosch GR2 with charge pump Bosch GR1 senza pompa sovralimentazione Bosch GR1 without charge pump Bosch GR2 senza pompa sovralimentazione Bosch GR2 without charge pump 1 2 3 4 5 6 5 - VALVOLA DI MASSIMA PRESSIONE - PRESSURE RELIEF VALVE 14 17 21 25 30 140 bar [2030 psi] 170 bar [2465 psi] 210 bar [3045 psi] 250 bar [3625 psi] 300 bar [4350 psi] STANDARD 6 - SENSO DI ROTAZIONE / DIRECTION OF ROTATION R L Destra CW Sinistra CCW 7 - ESTREMITÀ ALBERO / SHAFT END 1 Scanalato Maschio Z9-16/32-DP Splined T9-16/32-DP 2 Scanalato Maschio Z11-16/32-DP Splined T11-16/32-DP 52

CODICI DI ORDINAZIONE ORDERING CODE C1G 14/18/22 8 VERSIONE ATTACCHI / PORTS G U Filetti BSPP BSPP Threads SAE (Filetti UNF) SAE (UNF Threads) A Richiesta (quantità minima 50 pezzi) Upon Request (minimum quantity 50 pieces) 9 OPZIONI / OPTIONS 00 BP FI FE Senza Opzione Without Options By Pass By Pass Con Filtro With Filter Filtro con sensore elettrico Filter with Electric sensor 10 ESECUZIONI SPECIALI / SPECIAL VERSIONS 53

REGOLATORE ELETTRICO PROPORZIONALE NON RETROAZIONATO ELECTRIC PROPORTIONAL WITHOUT FEED-BACK CONTROL EP2/EP4 La pompa assume una cilindrata proporzionale alla corrente di alimentazione di uno dei due magneti installati sulla pompa. Comando influenzato dalla pressione di esercizio. A parità di segnale d ingresso (corrente di pilotaggio) la pompa può variare leggermente la cilindrata e la portata erogata all aumentare della pressione d esercizio. La corrente di alimentazione dei due elettromagneti proporzionali deve essere controllata da una scheda di regolazione esterna. L'alimentazione dell'uno o dell'altro elettromagnete definisce il senso di mandata. Gli elettromagneti standard sono del tipo proporzionale a 24V c.c. corrente massima 1A. (Opzionali elettromagneti 12V c.c. corrente massima 2A). Per movimentazioni di sola emergenza è comunque possibile comandare i solenoidi direttamente con una tensione 24V c.c.(ovvero 12V c.c.) escludendo la scheda. The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. Flow is also influenced by the working pressure. With a given input signal (piloting current) the pump can slightly vary the displacement and the flow when working pressure increases. The input current of the two proportional solenoids must be controlled by an external amplifier card. Flow direction depends on which solenoid is energized. Standard solenoids are proportional 24V d.c. max. current 1A. (Optional solenoids 12V d.c. max. current 2A). For emergency operation only it is however possible to control solenoids directly with 24V d.c.voltage (or 12V d.c.), by-passing the amplifier. Per le valvole proporzionali usare connettori con queste caratteristiche DEUTSCH CONNECTOR - DT04-2P (non inclusi ma fornibili) For proportional valve use connector whit this features: DEUTSCH CONNECTOR - DT04-2P (not included but can be supplied) Solenoide 12V-24V: Corrente min. 450 ma max 1300 ma Senso di rotazione: Correlazione tra il senso di rotazione della pompa (visto dal lato albero) e l azionamento del regolatore. Direction of rotation: Correlation between direction of rotation (shaft view) control and direction of flow. DIREZIONE PORTATA POMPA PUMP FLOW DIRECTION ROTAZIONE ALBERO SHAFT ROTATION SINISTRO (L) DESTRO (R) Alimentazione Magnete Energized solenoid Pressione ramo Oil outlet 1 B 2 A 1 A 2 B 54 C1 14/18

DIMENSIONI POMPA E REGOLATORI PUMP AND CONTROLS DIMENSION EP2/EP4 Connettori DEUTSCH - DT04-2P non inclusi ma fornibili DEUTSCH CONNECTOR - DT04-2P not included but can be supplied Versione METRICA / METRIC Version A B: Linee di pressione / Pressure ports 1/2 G D1 D2: Drenaggi / Drain port 3/8 G S: Aspirazione / Suction port 1/2 G P: Sovralimentazione / Charge pressure port 1/4 G VA: Valvola di alimentazione / Charge pump valve V1 V2: Valvole di massima / Maximum pressure valves SL: Limitatore di cilindrata / Stroke limiter ZM: Vite azzeratore meccanico / Mechanical zero adjustment screw ZI: Regolazione zero idraulico / Hydraulic zero regulation screw a b: attacchi per pilotaggio / Control piloting pressure port - 1/4 G Versione SAE / SAE Version A B: Linee di pressione / Pressure ports 3/4-16 UNF-2B D1 D2: Drenaggi / Drain port 9/16-18 UNF-2B S: Aspirazione / Suction port 3/4-16 UNF-2B P: Sovralimentazione / Charge pressure port 7/16-20 UNF-2B VA: Valvola di alimentazione / Charge pump valve V1 V2: Valvole di massima / Maximum pressure valves SL: Limitatore di cilindrata / Stroke limiter ZM: Vite azzeratore meccanico / Mechanical zero adjustment screw ZI: Regolazione zero idraulico / Hydraulic zero regulation screw a b: attacchi per pilotaggio / Control piloting pressure port - 7/16-18 UNF-2B 55 C1 14/18