FRG/2MBH... - FRG-RG/2MCSH P 2

Documenti analoghi
MADE IN ITALY. Gas pressure regulator Regolatore di pressione per gas FG/FGB 100/ / / /510

Mod. VS/AM VALVOLE DI SFIORO E SICUREZZA RELIEF VALVES AND SAFETY DEVICES

filtro separatore G1 G1 filter-water-separator

filtro separatore G1/4 G1/4 filter-water-separator

valvole ad azionamento meccanico mechanically actuated valves

MOTORI AD INGRANAGGI GEAR MOTORS

HTM SS 316 PUMPS Metallic mag drive centrifugal pumps POMPE HTM SS 316

Gruppi di riduzione e misura gas Gas pressure reducing and metering stations

VALVOLE IDROPNEUMATICHE IN MATALLO / METAL DIAPHRAGM VALVES LINEA DI PRESSIONE LINE PRESSURE CAMERA SUPERIORE UPPER CHAMBER

GAS and AIR Equipment

Filtri gas / Gas filters

gruppo trattamento aria FR+L G1/4

REGOLATORI DI PRESSIONE

> RUBINETTI A GALLEGGIANTE > FLOAT TAPS

NEWS 68. Valves and Solenoid valves Poppet system N776 Series

gruppo trattamento aria FR+L G1/4

Componenti per impianti a gasolio, olio combustibile e gas

Pressostato con scala di taratura visiva Pressure switch with setting visual scale

VALVOLE DI SFIATO ARIA AUTOMATICHE AUTOMATIC AIR VENT VALMAT VALMAT AUTOMATIC AIR VENT VALMAT VALVOLE DI SFIATO ARIA AUTOMATICHE VALMAT

Omologazione Homologation Bestaetigt. PN 40 k 0,72 Diametro orifizio Opening diameter Innen durckmesser

capitolo V - gruppi trattamento aria chapter 5 - air preparation units

Regolatori Civili - Industriali per Metano/GPL Bassa-Media-Alta pressione Domestic - Industrial regulators for methane/lpg low-medium-high pressure

Stabilizzatori Mod. STAB Stabilizzatori

Pneumatica. Pneumatic. Pneumatica Pneumatic > 891

SERIE APM-110 BAR SERIES. Filtri in linea a media pressione In line filter medium pressure. Filtri - Filters 09

Valvole Singola Sede di Fondo BBZO/BBZOG BBZO/BBZOG Single Seat tank bottom valves

capitolo VII - gruppi trattamento aria

Regolatore di pressione di gas Gas pressure governor Series FS1B - ST1B

Dival 600 Regolatori di Pressione

POMPA A MANO MODULARE DI EMERGENZA

Regolatore di pressione di gas Gas pressure governor Serie FGD-FGDR-FG1B

THOR SPLIT BODY ANSI IN ACCIAIO INOX STAINLESS STEEL THOR SPLIT BODY ANSI

VALVOLE DI SFIORO. Serie V. Process Management TM. Tipo V/20-2. Tipo V/50. Tipo V/60

BVBA POMAC-LUB-SERVICES SPRLKorte Bruggestraat 28 B-8970 Poperinge Tel. 057/ Fax 057/ internet:

QM Quadri di decompressione modulari a doppio ingresso CARATTERISTICHE

INDICE VISIVO VISUAL INDEX

9.9 / moda1 / Gruppo 1 Art. 3 Punto 1.3 lettera b) primo trattino/olio. Via Lecco 69/ AGRATE BRIANZA (MI) - ITALY

SERIE HPB BAR SERIES. Filtri alta pressione High pressure filters. Filtri - Filters 10

pressostati pressure switches

Campo di misura Range Pressione relativa Relative pressure. Campo di misura Range Pressione assoluta Absolute pressure mbar bar bar

THOR SPLIT BODY ANSI IN ACCIAIO CARBONIO CARBON STEEL THOR SPLIT BODY ANSI

Addolcitori Softeners

Quick start manual Manuale rapido. Version 3.0

Sezione 1 / Section 1. Elementi d identità: il marchio Elements of identity: the logo

VPA. Aseptic sampling valve. Type VPA

24V DC ±10% W. Fluido Fluid. 15 Nl/min

VALVOLE DI SICUREZZA

Regolatori idraulici di velocità Hydraulic speed regulators SERIE 330

EVPF/NC - DN P. max 360 mbar

SERRATURE PER SERRANDE E TAPPARELLE ROLLER SHUTTER, LIGHT BOTTOM BAR AND METAL CABINET LOCK GENERAL SPECIFICATION SPECIFICHE GENERALI

VALVOLE CORPO FILETTATO CON OTTURATORE BREVETTATO VALVES WITH THREADED POPPET BODY PATENTED SYSTEM

MG3A-ABS 40 MANOMETRI A MOLLA BOURDON BOURDON TUBE PRESSURE GAUGES PRESSURE GAUGES MANOMETRI. Opzioni : vedi pagina 103. Options : see page 103

HTP Metallic rotary vane mag drive pumps dry self-priming HTP Pompe rotative a palette e a trascinamento magnetico in metallo, autoadescanti a secco

COMPONENTI PER IMPIANTI IDRAULICI/ RISCALDAMENTO COMPONENTS FOR PLUMBING AND HEATING SYSTEM

GS6A GS6A SERIES TECHNICAL CATALOGUE CATALOGO TECNICO SERIE GS6A Potenza di picco (²) Peso approssimativo unità Capacità olio motore

ref. 1 Star A Cabina doccia angolare a 4 ante, 2 scorrevoli e 2 fi sse / Corner entry

SERIE - SERIES SRC SRC-A SERRANDA DI TARATURA DUCT DUMPERS

BILANCIAMENTO / BALANCING

NDCMB NDCMB MOTORIDUTTORI C.C. AD ASSI ORTOGONALI RARE EARTH D.C. BEVEL HELICAL GEARMOTORS

KM-L Lever Operated Stainless Steel Monitor.pdf KML-B Lever Operated Bronze Monitor.pdf KM-L-P Portable Monitor.pdf KM-V&2V-3X DN 80 Handwheel

Filtri autopulenti Self-cleaning filters

RotorSospension Cube 12

SERRATURE PER PORTE BASCULANTI LOCKS FOR OVERHEAD GARAGE DOOR. a cilindro tondo round cylinder. a cilindro profilo European cylinder

HPP-HPF PUMPS POMPE HPP-HPF

Art Gruppo idraulico per impianti solari termici Hydraulic solar unit

REGISTRATION GUIDE TO RESHELL SOFTWARE

CURVATURA - BENDING C50 ES

O P T I O N A L COPERTURA INOX PAVIMENTO STAINLESS STEEL FLOOR COVERING

international GARDEN LINE CLEANING Revisione 6-09/2013 Cod

SERIE DP sezione 1 DP SERIES section 1

Regolatori di pressione alta pressione con blocco High pressure gas governor with shut off Serie ST4B-BM

Elettrovalvole a solenoide per gas, gasolio, nafta, acqua, vapore Valvole per intercettazione combustibile Sistemi di rilevamento gas e incendio

Flowmeters. Contatori Volumetrici

VALVOLE DI MASSIMA PRESSIONE RELIEF VALVES

TEST REPORT INDICE - INDEX

Generatori di Vapore Steam Jet Generator

Allegato al foglio tecnico riduttori /06/04

CONFIGURATION MANUAL

SENSORE AD INSERZIONE DISPONIBILE CON ACCESSORI PER MONTAGGIO IN LINEE SENZA PRESSIONE

MAGNUM SPLIT WAFER PN ANSI IN ACCIAIO AL CARBONIO CARBON STEEL MAGNUM SPLIT WAFER PN ANSI

SERIE SPIN-ON SERIES Filtri in linea Filters. Filtri - Filters 08

bruciatori TECNOPRESS gas, gasolio, olio combustibile e misti TECNOPRESS SERIES natural gas burners, dual fuel burners, light and heavy oil burners

SISTEMI DI GESTIONE MANAGEMENT SYSTEMS ISO 9001:2008 SISTEMI DI GESTIONE DELLA QUALITA QUALITY MANAGEMENT SYSTEMS

Combinazioni serie IL-MIL + MOT

Attuatore a relè Manuale di istruzioni

09 12 Combined tanks 01 16

Codice Descrizione dei lavori Quantità

ACCESSORI PER POMPE E MOTORI IDRAULICI HYDRAULIC PUMPS AND MOTORS ACCESSORIES

NASTRI SERIE 1000 CONVEYORS SERIES 1000

Filtri - Filters 10. Filtri alta pressione High pressure filters SERIE HPB BAR SERIES

SMART PIU' -28/112 9 greche POLYPIU'-PLAST S.R.L. VIA DELLE INDUSTRIE, GORNATE OLONA (VA)

ITALTRONIC GUIDE GUIDE

ACCESSORIES ACCESSORI

APN20 MULTIKIT_N2 10APN 015_MULTIKIT_

SERIE SG2-HAND APPLICAZIONI

24V DC ±10% W. Fluido Fluid. 15 Nl/min

Macchine ad Impatto Impact machines

CONTENITORI FILTRI INOX A CARTUCCIA

SCHEDA PRODOTTO DATA SHEET DS-SGD11 ED MANOMETRO DIFFERENZIALE SERIE SGD11 DIFFERENTIAL PRESSURE GAUGE SERIES SGD11

Sistemi di connessione Distribox e Spiderbox

Transcript:

- FRG-RG/2MCSH = 0,8 3,6 Section Chapter 3.0 RIDUTTORI DI PRESSIONE PER GAS DIRECT OPERATED GAS PRESSURE REGULATOR FRG/2MBH.. FRG-RG/2MCSH.. High Version II 2G - II 2D MADAS-03 DESCRIZIONE Riduttore di pressione per gas con otturatore compensato. FRG/2MCSH - RG/2MCSH Filtroregolatori e Regolatori di pressione SENZA blocchi di sicurezza Filtroregolatori di pressione CON blocchi di sicurezza DESCRIPTION Gas pressure regulator with compensated obturator. FRG/2MCSH - RG/2MCSH Filter regulators and Regulators WITHOUT safety shut off device Filter regulators WITH safety shut off device Possono essere dotato dei seguenti dispositivi di sicurezza e accessori: dispositivo di blocco per sovrappressione a valle (solo versioni 2MBH...): interrompe l erogazione quando la pressione in uscita del regolatore supera il valore di taratura del dispositivo. valvola di sfioro: scarica all esterno piccole portate di gas nel caso si verifichino sovrappressioni a valle del regolatore. Tale scarico è convogliabile all asterno nel caso di installazioni in ambienti con scarsa ventilazione. dispositivo di blocco di minima pressione a valle (solo versioni 2MBH...): interrompe l erogazione quando la pressione in uscita del regolatore scende al di sotto del valore di taratura del dispositivo. Interviene anche in caso di mancanza di alimentazione a monte. presa di pressione in uscita. filtro in entrata (eccetto RG/2MCSH) It can be equipped with the following safety devices and accessory: outlet over pressure shut off device (only 2MBH... versions): it stops the gas flow when the regulator outlet pressure goes up the device setting value. relief valve: it vents outside small quantity of gas in case there are downstream regulator overpressure. That exhaust it is convoyed outside in case of installation in environment with bad ventilation outlet low pressure shut off device (only 2MBH... versions): it stops the gas flow when the regulator outlet pressure goes down the device setting value. It closes even if there is no inlet pressure. outlet pressure test point. inlet filter (except RG/2MCSH) Norma di riferimento EN 88-2 - EN 334 In conformità a: Direttiva PED 2014/68/UE (ex 97/23/CE) Direttiva ATEX 2014/34/UE (ex 94/9/CE) Reference standard EN 88-2 - 334 In conformity with: 2014/68/EU PED Directive (ex 97/23/EC) 2014/34/EU ATEX Directive (ex 94/9/EC) Madas Technical Manual REV. 3 of 1 st October 2016 FRG-RG/2MCSH 1

Section Chapter 3.0 - FRG-RG/2MCSH = 0,8 3,6 Impiego / Use: gas non aggressivi delle 3 famiglie (gas secchi) not aggressive gases of the 3 families (dry gases) Attacchi filettati Rp / Threaded connections Rp: DN 1 secondo EN 10226 SU RICHIESTA ATTACCHI NPT DN 1 according to EN 10226 ON REQUEST NPT CONNECTIONS Attacchi flangiati PN 16 / Flanged connections PN 16: secondo ISO 700 SU RICHIESTA ATTACCHI ANSI 10 according to ISO 700 ON REQUEST ANSI 10 CONNECTIONS Pressione min esercizio / Min. working pressure: 0, Pressione max esercizio / Max. working pressure: (vedi etichetta prodotto) (see product label) Temperatura ambiente / Environment temperature: -20 +60 C Temperatura superficiale max / Max superficial temperature: +60 C Classe accuratezza P2 / P2 accuracy class: AC 10 Classe accuratezza OPSO / OPSO accuracy class: AG 10 Classe pressione di chiusura / Closing pressure class: SG 10 Resistenza meccanica / Mechanical strength: Gruppo 2 (secondo EN 13611:2007) Group 2 (according to EN 13611:2007) Campo pressione intervento / Trip pressure range: vedere tabella molle see springs table Tempo di chiusura blocco / Shut off closure time: < 1 s Valvola di sfioro / Relief valve testata secondo EN 334 tested according to EN 334 Connessione dello sfiato: / Vent connection: G 1/4 Filtraggio / Filtration (solo/only FRG/2MBH): 0 µm (su richiesta altre qualità di filtraggio) 0 µm (on request other filtration qualities) Classe di filtrazione / Filtration class: G 2 (secondo EN 779) G 2 (according to EN 779) Materiali / Materials / Matériels / Materiales: Alluminio pressofuso (UNI EN 1706) Ottone OT-8 (UNI EN 12164) Alluminio 11S (UNI 9002-) Acciaio INOX 430 F (UNI EN 10088) Gomma antiolio NBR (UNI 49) Nylon 30% fibra di vetro (UNI EN ISO 11667) Viledon Die-cast aluminium (UNI EN 1706) OT-8 brass (UNI EN 12164) 11S aluminium (UNI 9002-) F stainless steel (UNI EN 10088) NBR rubber (UNI 49) Nylon 30% glass fibre (UNI EN ISO 11667) Viledon 2 FRG-RG/2MCSH Madas Technical Manual REV. 3 of 1 st October 2016

- FRG-RG/2MCSH = 0,8 3,6 Section Chapter 3.0 TABELLA COSTRUZIONE FRG-RG MODELLI 2MBH (Z-F-R-M) TABLE CONSTRUCTION FRG-RG/2MBH (Z-F-R-M) MODELS MODELLO MODEL ATTACCO CONNECTION CONFIGURAZIONE IN/OUT IN/OUT CONFIGURATION MOLLA P2 P2 SPRING MOLLA OPSO OPSO SPRING MOLLA UPSO UPSO SPRING MOLLA SFIORO RELIEF SPRING FBH 03 F 1 1 2 1 CON FILTRO WITH FILTER DN 20 0,9 1, 1 2 1,4 2,6 0,2 1 FBH 04 R 3 3 X X CON FILTRO WITH FILTER 1,8 3,6 3,2 4,2 senza UPSO without UPSO senza sfioro without relief In tabella sono riportati alcuni esempi per illustrare come è possibile combinare tra di loro le molle di taratura. Per i modelli compact 2MBH... : gli attacchi DN 1 - DN 20 - sono disponibili solo con filtro in dotazione si possono cambiare le molle di taratura OPSO è sempre presente, si può omettere UPSO (indicare molla n 3 con X ), si può omettere lo sfioro (indicare molla n 4 con X ), in tali casi il prezzo non subisce variazioni; Non tutte le combinazioni sono possibili, devono essere funzionalmente compatibili. Si consiglia di contattare il nostro ufficio commerciale per la conferma della fattibilità. Table shows some examples to illustrate how you can combine the setting springs. For 2MBH... compact models: DN 1 - DN 20 - connections are available only with built-in filter, all other connections are not equipped with filter; only for DN 1 - DN 20 - regulators you can change the setting springs, for DN 32 to DN 100 they are not interchangeable OPSO is always present, you can omit UPSO (indicating spring No. 3 with X ), you can omit the relief (indicating spring No. 4 with X ), in such cases the price will not change; Not all combinations are possible, they must be functionally compatible. It is advisable to contact our sales department for confirmation of feasibility. MODELLO MODEL ATTACCO CONNECTION TABELLA COSTRUZIONE CODICI RG-FRG MODELLI 2MCSH TABLE CONSTRUCTION RG-FRG/2MCSH MODELS VERSIONE VERSION MOLLA P2 P2 SPRING MOLLA OPSO OPSO SPRING MOLLA UPSO UPSO SPRING MOLLA SFIORO RELIEF SPRING FCSH 03 0000 2 X X 1 CON FILTRO WITH FILTER DN 20 P1= 0, 1, 1,8 senza OPSO without OPSO senza UPSO without UPSO 0,2 1 RCSH 04 0000 3 X X X SENZA FILTRO WITHOUT FILTER P1= 0, 1,8 3,6 senza OPSO without OPSO senza UPSO without UPSO senza sfioro without relief In tabella sono riportati alcuni esempi per illustrare come costruire il codice prodotto finito combinando tra di loro le molle di taratura. Per i modelli 2MCSH : le versioni con filtro sono disponibili solo negli attacchi DN 1 - DN 20 -, tutti gli altri attacchi non sono dotati di filtro; Si possono cambiare le molle di taratura su tutti i diametri. Non possono essere presenti OPSO e UPSO (quindi molle n 2 e n 3 sempre indicate con X ); Si può omettere lo sfioro contrassegnando con una X il campo molla corrispondente (n 4), in tal caso il prezzo non subisce variazioni; Non tutte le combinazioni sono possibili, devono essere funzionalmente compatibili. Si consiglia di contattare il nostro ufficio commerciale per la conferma della fattibilità. Table shows some examples to illustrate how you can combine the setting springs. For 2MCSH models: Versions with built-in filter are available in DN 1 - DN 20 -, all other connections are not available with filters; On regulators you can change the setting springs. OPSO and UPSO are not present (in this case springs No. 2 and No. 3 always marked with X ); You may omit the relief marking an X the corresponding spring range (n 4), in this case the price will not change; Not all combinations are possible, they must be functionally compatible. It is advisable to contact our sales department for confirmation of feasibility. Madas Technical Manual REV. 3 of 1 st October 2016 FRG-RG/2MCSH 3

Section Chapter 3.0 - FRG-RG/2MCSH = 0,8 3,6 fig. 1 (DN 1-20 - 2) FRG/2MBH fig. 1 1 - Vite di regolazione P2 2 - Molla di taratura P2 3 - Molla di taratura sfioro 4 - Disco superiore per membrana - Viti di fissaggio 6 - Corpo 7 - Organo filtrante 8 - Otturatore (blocco) 9 - Fondello 10 - Tappo di chiusura (blocco) 11 - Flangia 12 - Membrana di compensazione 13 - Perno centrale (blocco) 14 - Membrana di funzionamento blocco 1 - Molla di taratura blocco max 16 - Regolazione taratura blocco max 17 - Regolazione taratura blocco min 18 - Perno di riarmo 19 - Molla blocco min 20 - Imbuto 21 - Perno centrale (regolatore) 22 - Otturatore (regolatore) 23 - Presa di pressione 24 - Membrana di funzionamento 2 - Tappo antipolvere 26 - Regolazione sfioro 27 - Tappo di chiusura (regolatore) 28 - Chiave speciale per taratura fig. 1 1 - P2 calibration screw 2 - P2 setting spring 3 - Relief valve setting spring 4 - Diaphragm upper disc - Fixing screws 6 - Body 7 - Filtering organ 8 - Obturator (shut off) 9 - Bottom 10 - Closing cap (shut off) 11 - Flange (only on standard version) 12 - Compensation diaphragm 13 - Central pin (shut off) 14 - Working shut off diaphragm 1 - Max shut off setting spring 16 - Max shut off calibration 17 - Min shut off calibration 18 - Reset pin 19 - Min shut off setting spring 20 - Funnel 21 - Central pin (regulator) 22 - Obturator (regulator) 23 - Pressure nipple 24 - Working diaphragm 2 - Antidust cap 26 - Relief calibration 27 - Closing cap (regulator) 28 - Special key for setting 4 FRG-RG/2MCSH Madas Technical Manual REV. 3 of 1 st October 2016

- FRG-RG/2MCSH = 0,8 3,6 Section Chapter 3.0 fig. 2 (DN 1-20 - 2) RG-FRG/2MCSH fig. 2 1 - Vite di regolazione P2 2 - Molla di taratura P2 3 - Molla di taratura sfioro 4 - Disco superiore per membrana - Viti di fissaggio 6 - Corpo 7 - Organo filtrante (solo su FRG...) 9 - Fondello 20 - Imbuto 21 - Perno centrale (regolatore) 22 - Otturatore (regolatore) 23 - Presa di pressione 24 - Membrana di funzionamento 2 - Tappo antipolvere 26 - Regolazione sfioro 27 - Tappo di chiusura (regolatore) 28 - Chiave speciale per taratura fig. 2 1 - P2 calibration screw 2 - P2 setting spring 3 - Relief valve setting spring 4 - Diaphragm upper disc - Fixing screws 6 - Body 7 - Filtering organ (only on FRG...) 9 - Bottom 20 - Funnel 21 - Central pin (regulator) 22 - Obturator (regulator) 23 - Pressure nipple 24 - Working diaphragm 2 - Antidust cap 26 - Relief calibration 27 - Closing cap (regulator) 28 - Special key for setting Madas Technical Manual REV. 3 of 1 st October 2016 FRG-RG/2MCSH

Section Chapter 3.0 - FRG-RG/2MCSH = 0,8 3,6 ATTACCHI FILETTATI - THREADED CONNECTIONS FOTO PHOTO ATTACCHI CONNECTIONS P2 OPSO UPSO CAMPO DIFFERENZIALE SFIORO DIFFERENTIAL RELIEF VALVE 1 0,9 1, 1 1 2 1 0,6 0,8 1 0,2 1 FBH02Z 1111 DN 1 2 1, 1,8 2 2,2 3,3 1 0,6 0,8 1 0,2 1 FBH02Z 2211 3 1,8 3,6 3 3,2 4,2 2 1,4 2,6 1 0,2 1 FBH02Z 3321 1 0,9 1, 1 1 2 1 0,6 0,8 1 0,2 1 FBH03Z 1111 DN 20 2 1, 1,8 2 2,2 3,3 1 0,6 0,8 1 0,2 1 FBH03Z 2211 3 1,8 3,6 3 3,2 4,2 2 1,4 2,6 1 0,2 1 FBH03Z 3321 1 0,9 1, 1 1 2 1 0,6 0,8 1 0,2 1 FBH04Z 1111 2 1, 1,8 2 2,2 3,3 1 0,6 0,8 1 0,2 1 FBH04Z 2211 3 1,8 3,6 3 3,2 4,2 2 1,4 2,6 1 0,2 1 FBH04Z 3321 In tabella sono indicati i codici delle versioni più comuni con sfioro e UPSO incorporati. Table shows codes of the more common versions with built-in relief and UPSO. I CODICI SONO RIFERITI ALLA VERSIONE Z. Sostituire la lettera Z dei codici indicati in tabella con la lettera corrispondente alla versione voluta. S ARE REFERRED TO VERSION Z. Replace the letter Z of the codes indicated in the table with the corresponding letter you need. ATTACCHI FILETTATI - THREADED CONNECTIONS FOTO PHOTO ATTACCHI CONNECTIONS P2 CAMPO DIFFERENZIALE SFIORO DIFFERENTIAL RELIEF VALVE FILTROREGOLATORE FILTER REGULATOR REGOLATORE REGULATOR 1 0,9 1, 1 0,2 1 FCSH020000 1XX1 RCSH020000 1XX1 DN 1 2 1, 1,8 1 0,2 1 FCSH020000 2XX1 RCSH020000 2XX1 3 1,8 3,6 1 0,2 1 FCSH020000 3XX1 RCSH020000 3XX1 1 0,9 1, 1 0,2 1 FCSH030000 1XX1 RCSH030000 1XX1 DN 20 2 1, 1,8 1 0,2 1 FCSH030000 2XX1 RCSH030000 2XX1 3 1,8 3,6 1 0,2 1 FCSH030000 3XX1 RCSH030000 3XX1 1 0,9 1, 1 0,2 1 FCSH040000 1XX1 RCSH040000 1XX1 2 1, 1,8 1 0,2 1 FCSH040000 2XX1 RCSH040000 2XX1 3 1,8 3,6 1 0,2 1 FCSH040000 3XX1 RCSH040000 3XX1 In tabella sono indicati i codici delle versioni possibili e con sfioro incorporato. Per i codici delle versioni senza sfioro vedere esempi tabella costruzione codici 2MCSH a pag. 3 E' possibile modificare il campo di taratura selezionando la molla idonea tra i ricambi. Table shows codes of the more common versions with built-in relief. For codes without relief versions see examples table 2MCSH construction codes on p. 3. You can change the setting by selecting the appropriate spring between the parts. 6 FRG-RG/2MCSH Madas Technical Manual REV. 3 of 1 st October 2016

- FRG-RG/2MCSH = 0,8 3,6 Section Chapter 3.0 FRG/2MBH (Z-F-R-M) DN 1 - DN 20 - MOLLE DI TARATURA P2 P2 SETTING SPRINGS RG-FRG/2MCSH DN 1 - DN 20 - MOLLE DI TARATURA P2 P2 SETTING SPRINGS 0,9 1, MO-130 3,x29,8x98x11, 1, 1,8 MO-20 4x29x98x8 1,8 3,6 MO-290 4,x29,x94x10 MOLLE DI TARATURA OPSO OPSO SETTING SPRINGS 0,9 1, MO-130 3,x29,8x98x11, 1, 1,8 MO-20 4x29x98x8 1,8 3,6 MO-290 4,x29,x94x10 MOLLE DIFFERENZIALE SFIORO DIFFERENTIAL RELIEF VALVE SPRINGS 1 2 MO-0890 2,x30x27x3 0,2 1 MO-210 2x17x4x9 2,2 3,3 MO-099 3x3x30x3, 3,2 4,2 MO-0990 3x3x33,x3, MOLLE DI TARATURA UPSO UPSO SETTING SPRINGS 0,6 0,8 MO-020 1,2x1x40x 1,4 2,6 MO-21 2x17x29x6 MOLLE DIFFERENZIALE SFIORO DIFFERENTIAL RELIEF VALVE SPRINGS 0,2 1 MO-210 2x17x4x9 Madas Technical Manual REV. 3 of 1 st October 2016 FRG-RG/2MCSH 7

Section Chapter 3.0 - FRG-RG/2MCSH = 0,8 3,6 DATI DI STABILIZZAZIONE () STABILIZATION DATA () P1 P2 (m) 1000 2000 3000 1, 100 - - 2 160 - - 2, 190 160-3 220 240 3, 20 20 20 4 300 310 320 30 430 440 6 400 30 0 Dimensioni di ingombro in mm Overall dimensions in mm Attacchi Filettati Threaded Connections Attacchi Flangiati Flanged Connections A B C DN 1 - DN 20-120 237 143 191 237 143 RG-FRG/2MCSH... Attacchi Filettati Threaded Connections Attacchi Flangiati Flanged Connections A B C DN 1 - DN 20-120 194 140 B C A 191 22 140 INSTALLAZIONE / MANUTENZIONE IMPORTANTE Consultare attentamente il manuale di istruzioni a corredo del prodotto per conoscere le avvertenze e le modalità di installazione e manutenzione INSTALLATION / SERVICING IMPORTANT Read carefully the operating instructions manual supplied with the product for the warnings and installation and maintenance procedures 8 FRG-RG/2MCSH Madas Technical Manual REV. 3 of 1 st October 2016