ASSEMBLY MANUAL GUIDA PER IL MONTAGGIO OPTIKA MICROSCOPES - ITALY

Documenti analoghi
Istruzioni di montaggio per ECOFLEX KIT Assembling Instructions for ECOFLEX KIT

NOTE DI ASSEMBLAGGIO ASSEMBLY NOTE pag. 1/5 Y102 YAMAHA MT x1

ISTRUZIONI PER IL MONTAGGIO DEL KIT SSD INSTRUCTIONS TO INSTALL THE KIT SSD

NOTE DI ASSEMBLAGGIO ASSEMBLY NOTE pag. 1/5 Y104 YAMAHA MT x1

Istruzioni di montaggio per l ECOFLEX KIT Assembling Instructions for ECOFLEX KIT

SACE Emax Operazioni preliminari - Preliminary Operations. 2 - Verifica contenuto kit - Kit content verify C X8 B D X4.

MANUALE MONTAGGIO MOTORI SERIE VEGL MOTOR ASSEMBLY MANUAL VEGL SERIES

SCHEMA DI MONTAGGIO CREDENZA SEQUENCE ASSEMBLING SHEET SIDEBOARD SEQUENCE

sensori per cilindri magnetic sensors for cylinders

sensori per cilindri magnetic sensors for cylinders Schema di collegamento: 2 fili Wiring diagram: 2 wires RS2-A RS1-A RS3-A RS4-A RS5-C Modello Model

ASSEMBLING INSTRUCTION LICENSE PLATE HOLDER CBR 1000 RR 2010

INSTALLAZIONE KIT DOSATORE DI DETERGENTE DETERGENT DISPENSER KIT INSTALLATION

Libretto uso e manutenzione. Owner s handbook. rev /07

ART. 1254AL155SS CERNIERE PER PORTE A SPINGERE MANO SINISTRA / HINGES FOR LEFT-HAND DOORS

Istruzioni per l installazione Installation guide

Replacement of hose carrier chain

ASSEMBLY NOTE / SCHEDA DI MONTAGGIO pag.1/5 D155 Ducati Panigale 1299 Coppia sil.

UT / RT 1306_C.doc 26/08/04. Pagina 1/8

RUBINETTO IN CRISTALLO/TAP SHELF IN GLASS

Centrale MK3 MK3 power packs

DOGMA XM Istruzioni di montaggio coppie di serraggio DOGMA XM Assembling procedure tightening torques

Dispensatore COROB COROB Dispenser

Acer Aspire TimelineU M5-481TG Audio Drive

Manuale Handbook. Via Torino Piagera di Gabiano (AL) - ITALIA Tel xxxxxx - fax +39 xxxxx. support.race@dimsport.

Contents of Kit Contenuto del Kit

- - Istruzioni per l installazione Installation guide

Istruzioni per l installazione Installation guide

ISTRUZIONI DI MONTAGGIO

SACE Emax Operazioni preliminari - Preliminary Operations. 2 - Verifica contenuto kit - Kit content verify 1 OK 2 OK

Serie B-150 B-150. Microscopi biologici avanzati per studenti. Microscopi biologici avanzati per studenti B-150

INSTALLAZIONE INSTALLATION

Istruzioni per l installazione Installation guide

ST CLS. Manuale di installazione ed uso. Figura 1 LINGUA ITALIANO COLONNA PER BARRIERE LS

Adattatori Morsa BDMpro

BDMPro Positioning Frame

TUBO RAME - TUBO INOX COPPER PIPE - STEEL PIPE SERIE 200 T FILE 200 T. Raccordi a compressione con ogiva in P.T.F.E.

INNESTO DELLE LAMELLE A TELAIO CHIUSO CON COMPENSAZIONE RAPIDA COUPLING OF SLATS IN CLOSED FRAME WITH RAPID ADJUSTMENT

microscopi BioLoGici e stereo per la didattica

TUBO POLIETILENE RETICOLATO Winny-pex. CROSS-LINKED POLYETHYLENE PIPE Winny-pex. Raccordi a compressione per tubo in polietilene reticolato

Istruzioni per lo smontaggio delle Lancette; smontaggio quadrante e la regolazione della lancetta dei minuti.

SISTEMA COMPLETO DI ILLUMINAZIONE VANO LAMPADA A LED TIPO ILV24 s. COMPARTMENT SYSTEM LIGHTING COMPLETE LED LAMP TYPE ILV24 s

ISTRUZIONI MONTAGGIO KIT PORTATARGA HONDA CBR 1000 RR 08 ESTR- 0111

controlli di livello capacitivi capacitive levels controls

RUBINETTERIA GRANDI IMPIANTI. MANUALE D USO x RUBINETTI DI SCARICO USER MANUAL FOR DRAIN COCK

ATTENZIONE! / WARNING! Scollegare le batterie prima di qualsiasi operazione! Disconnect batteries before servicing! Kit caricabatteria :

Accessori / Accessories

RIDUTTORI PER MOTORI A SCOPPIO GEARBOX FOR PETROL ENGINES

sottobasi per valvole a spola

Microscopi polarizzati da laboratorio

Mod INTERFACCIA ETHERNET ETHERNET INTERFACE. Sch./Ref. 1067/007

CAMBIO OLIO TRIAL LATO DESTRO TRIAL OIL CHANGE RIGHT SIDE

UNIVERSITÀ DEGLI STUDI DI TORINO

Manuale per il collegamento e l uso Installation and operation manual

MODELLO-MODEL NON CONFORMI AD ALCUNA NORMATIVA DIN/ISO SULLA SICUREZZA DO NOT COMPLY WITH ANY DIN/ISO SAFETY STANDARD

mounting instruction Speed Triple Valve Racing kit (Cod )


SACE Emax Operazioni preliminari - Preliminary Operations. 2 - Verifica contenuto kit - Kit content verify 1 OK 2 OK

DISPOSITIVO DI COMANDO PROPORZIONALE AIR PROPORTIONAL CAB SWITCH

ESTR ESTR-0709 Portatarga regolabile per Triumph Speed Triple S (2016)

IM123.0 ISTRUZIONI DI MONTAGGIO ASSEMBLY DIAGRAM LETTO BED45 CON MECCANISMO: BED BED45 WITH MECHANISM:

Prefiltri Prefilter ISTRUZIONI PER L USO OPERATING INSTRUCTIONS

SCHEMI DI MONTAGGIO ASSEMBLY DIAGRAM

SOSTITUZIONE REPLACEMENT ABBINAMENTO A LEVA CODICE A DX A SX LEVER RETRACTABLE CAM REF. A RX A LX

P/N DESCRIPTION QUANTITY

Connettori IP68 guida per il corretto cablaggio. IP68 connectors guide for the correct wiring

How to connect SL Controllers to your computer

I CAMBIAMENTI PROTOTESTO-METATESTO, UN MODELLO CON ESEMPI BASATI SULLA TRADUZIONE DELLA BIBBIA (ITALIAN EDITION) BY BRUNO OSIMO

BUSSOLE CONICHE DI SERRAGGIO - DATI TECNICI TAPER BUSHES - THECNICAL DATA

Image distorsion wheels

3-Facet prism module

SCHEDA TECNICA DI PRODOTTO Product Tech Datasheet

pag 1 / 13 CAROTIERE A CAVO-WIRE CORE BARREL D Rev. 0 del

INSTALLAZIONE INSTALLATION

Mod INTERFACCIA USB/KEY USB/KEY INTERFACE. Sch./Ref.1067/003

CEDMEGA Rev 1.2 CONNECTION TUTORIAL

manuale di identità visiva visual identity manual

MORSETTIERE ELETTRICHE BRASS CABLE-LUGS FUSIONE LAVORAZIONI MECCANICHE MONTAGGIO TRATTAMENTO SUPERFICIALE CASTING MECHANICAL OPERATIONS ASSEMBLYING

ISTRUZIONI DI INSTALLAZIONE SCREENAPP ASSEMBLY & INSTALLATION INSTRUCTIONS

M-LOCK Serratura magnetica per porte in vetro a battente. M-LOCK Magnetic lock for glass swing doors

ACTUATOR FOR MIXING VALVES

CCTV DIVISION. Guida Alla Lettura del Numero Seriale, Codice Prodotto, Versione Firmware, Versione Software, Codice Libretto

Hoods and housings single locking system Custodie con sistema di chiusura a leva singola STD STD-HV 21.00

Light intensity regulator for Aim LED. Regolatore d intensità luminosa per Aim LED

ITALTRONIC SUPPORT XT SUPPORT XT

SEMPLICE LED. // Schemi cablaggio // Wiring diagrams. // Istruzioni per il montaggio // Assembly instructions

Manuale di montaggio. Yamaha Tmax cod. CJP1027. Schema di montaggio della centralina

ML04-XJ-EVO1 Riduttore di Pressione Iniezione GPL MANUALE DI REVISIONE

istruzioni di montaggio - manutenzione BUBBLE UP 300 MIN 160 MIN 160

M I C R O S C O P E S I T A L Y SZN STEREOZOOM HEAD OPERATION MANUAL MANUEL D INSTRUCTIONS GUIDA UTENTE MANUAL DE INSTRUCCIONES

instructions HD Street Footrest kit (206301)

A. T. S. ( Air Track Supply ) ALIMENTAZIONE con IMPIANTO SCORREVOLE

CARATTERISTICHE TECNICHE MODULO 60 TECNICAL SPECIFICATION. Caratteristiche tecniche e finiture

ECHO ECHO PLUS LCA MCA UGRV UGRS E E UGR/HS MCE MPE MFE MXE MTE MCC MPI PCDS PANNELLO DI COMANDO A DISTANZA SEMPLIFICATO

Italian 102 Daily Syllabus

INDICE INDEX TAVOLI IN CORIAN MANHATTAN MANHATTAN CORIAN TABLES TAVOLO TONDO SOHO SOHO ROUND TABLE

1Adhok. Fissaggio snodato con peso Codice:

Illuminazione Lighting

FIAT DUCATO. Ampliamento impianto di condizionamento per veicoli con:

KRIPTOS 80 _FRAMELESS _ 167 _ 167 ERREBILUCE

microscopi biologici per laboratorio

Transcript:

Ver. 2.0.0 B-500Ti-2/3/5 ASSEMBLY MANUAL GUIDA PER IL MONTAGGIO OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com

INDEX 1.0 DESCRIPTION page 3 2.0 UNPACKING AND ASSEMBLY page 3 Page 2

1.0 DESCRIPTION The following assembly procedure can be used for the multidiscussion systems B-500Ti-2, B-500Ti-3 and B-500Ti-5. The assembly sequence is almost identical for all systems. The microscope is a precision scientific instrument designed for long lasting life with a minimal maintenance, being built following the best optical and mechanical standards and developed for a daily use. Optika reminds that the present manual contains important informations for a safe use and a correct maintenance of the instrument. It has to be available for each user. Optika declines any responsibility deriving from instrument uses that do not comply with this manual. 2.0 UNPACKING AND ASSEMBLY The multidiscussion system is housed in a moulded Styrofoam container. Remove the tape from the edge of the container and lift the upper part of the container. Take care not to let optical items fall out end get damaged. Remove each part from the housing and place them of a sturdy table. 2.1 Install the microscope as indicated in the specific instruction manual. Do not install the observation head. 2.2 Place the splitter attachment of the multidiscussion system and tighten the lock screw on the right side of the microscope (Fig. 1). POINTER POSITION CONTROLLER (1) POINTER INTENSITY CONTROLLER (2) 2.3 In order to use the green arrow which will be used as a pointer, it is mandatory to turn on the main switch of the microscope body. Connect one terminal of the provided cable into the back side of the splitter and the other terminal into the connector placed of the upper part of the microscope. (Fig. 2). Now use the pointer position controller (1) or the pointer intensity controller (2) to adapt to specific needs position and intensity of the pointer. Page 3 Fig. 1 Fig. 2

2.0 UNPACKING AND ASSEMBLY 2.4 Begin to place the connection tubes on both sides of the splitter attachment. Firmly screw the black ring nut. (Fig. 3-4). Every connection is identified by a letter printed on both sides of the connection. Make sure to match the letters in order to correctly assemble the microscope. Fig. 3 2.5 Repeat the same procedure on the other side of the splitter (in case of B-500Ti-5) Fig. 4 2.6 Insert the second part of the extension tube (Fig. 6). At the end of the first extension tube there is a lens (Fig. 5). Make sure it is free from dirt, dust or other contaminants before to proceed with the assembling of the second extension tube. Fig. 5 2.7 Fully insert the second extension tube in the right position. Using the provided Allen wrench (small one) lock the fixing screws (1) to block the extension tube (Fig. 6). Fig. 6 Page 4

2.0 UNPACKING AND ASSEMBLY 2.8 Adjust the height of the multi-head holder. Loosen the base fixing knob (1), unscrew the base (2) in order to reach the desired height, then lock the knob. (Fig. 7). Fig. 7 2.9 Insert the optical head (always matching the reference letters) and screw the black fixing ring. (Fig. 8). Fig. 8 2.10 Insert the binocular heads, matching the reference letters (Fig. 9). Fig. 9 Page 5

2.0 UNPACKING AND ASSEMBLY 2.11 Insert the provided eyepieces (WF10X/20) into binocular heads. (Fig. 10). Fig. 10 2.12 Repeat all these operations for all the other observation points. 2.13 Install the trinocular head over the splitter, directly onto the microscope body. (Fig. 11) 2.14 Once completely assembled, the B-500Ti-5 looks like this. Fig. 11 Page 6 Fig. 12

INDICE 1.0 DESCRIZIONE pag. 9 2.0 RIMOZIONE DELL IMBALLAGGIO E MONTAGGIO pag. 9 Pagina 8

1.0 DESCRIZIONE Questa procedura di assemblaggio si applica ai sistemi per multi-osservazione B-500Ti-2, B-500Ti-3 e B-500Ti-5. La sequenza di montaggio è praticamente identica per tutti i sistemi. Il presente microscopio è uno strumento scientifico di precisione studiato per durare molti anni con una manutenzione minima, essendo costruito secondo i migliori standard ottici e meccanici e progettato per un utilizzo quotidiano. Optika ricorda che il presente manuale contiene informazioni importanti per un uso sicuro e una corretta manutenzione dello strumento. Esso deve quindi essere accessibile a chiunque lo utilizzi. Optika declina ogni responsabilità derivante da un uso improprio dei suoi strumenti non indicato dalla presente guida. 2.0 RIMOZIONE DELL IMBALLAGGIO E MONTAGGIO Il dispositivo per multi-osservazione si trova in un imballaggio di polistirolo espanso stampato. Dopo aver tolto il nastro adesivo da tutti gli imballi, sollevare la metà superiore dell imballaggio. Fare attenzione a non far cadere o danneggiare le componenti ottiche. Estrarre tutte le parti dai singoli alloggiamenti nell imballaggio ed appoggiarli su di un piano stabile. 2.1 Assemblare il microscopio come indicato nel manuale di istruzioni specifico dello strumento, senza montare la testata di osservazione. 2.2 Inserire il deviatore ottico del dispositivo per multi-osservazione e fissarlo con la vite di bloccaggio posta sul corpo del microscopio (Fig. 1). MANOPOLA SPOSTAMENTO FRECCIA LUMINOSA (1) MANOPOLA REGOLAZIONE INTENSITÀ FRECCIA LUMINOSA (2) Fig. 1 2.3 Per poter utilizzare la freccia luminosa verde che verrà usata come puntatore, si deve accendere l interruttore generale del microscopio posto nella parte posteriore dello strumento. Collegare un terminale del cavo in dotazione nella parte posteriore del deviatore ottico e l altro terminale nel connettore posto sulla parte superiore del microscopio. (Fig. 2). A questo punto usare la manopola di spostamento della freccia luminosa (1) o la manopola di regolazione dell intensità (2) per adattare alle proprie esigenze posizione e luminosità del puntatore. Fig. 2 Pagina 9

2.0 RIMOZIONE DELL IMBALLAGGIO E MONTAGGIO 2.4 Collegare la prima parte del tubo di estensione al deviatore ottico. Inserire il tubo nel deviatore fino in fondo ed avvitare completamente l anello nero di tenuta. (Fig. 3-4). Ogni singolo punto di connessione è identificato da una lettera. Verificare di fare combaciare le lettere durante la procedura di montaggio. Fig. 3 2.5 Ripetere la stessa operazione sul lato opposto del deviatore (nel caso del B-500Ti-5) Fig. 4 2.6 Inserire la seconda parte del tubo di estensione (Fig. 6). La parte terminale del primo tubo di estensione è chiusa da una lente (Fig. 5). Verificare che sia esente da sporco, polvere o altri contaminanti prima di procedere con il montaggio del secondo tubo di estensione. Fig. 5 2.7 Inserire fino in fondo il secondo tubo di estensione nella posizione esatta. Usando la brugola in dotazione (quella piccola) bloccare le viti di fissaggio (1) per fissare il tubo di estensione (Fig. 6). Fig. 6 Pagina 10

2.0 RIMOZIONE DELL IMBALLAGGIO E MONTAGGIO 2.8 Regolare l altezza della colonna di supporto del tubo di estensione. Allentare la manopola di serraggio della base (1), svitare la base (2) fino a raggiungere l altezza desiderata, serrare la manopola. (Fig. 7). Fig. 7 2.9 Inserire la testata ottica (sempre facendo coincidere le lettere di riferimento), e serrare l anello nero di tenuta. (Fig. 8). Fig. 8 2.10 Inserire le teste di osservazione binoculari, sempre rispettando le lettere di riferimento (Fig. 9). Fig. 9 Pagina 11

2.0 RIMOZIONE DELL IMBALLAGGIO E MONTAGGIO 2.11 Inserire gli oculari in dotazione (WF10X/20) nelle testate di osservazione. (Fig. 10). Fig. 10 2.12 Ripetere le stesse operazioni per tutti gli altri punti di osservazione. 2.13 Montare la testata trinoculare sul deviatore ottico direttamente sopra il corpo del microscopio. (Fig. 11) 2.14 Una volta terminato l assemblaggio, il B-500Ti-5 si presenta così. Fig. 11 Fig. 12 Pagina 12

www.optikamicroscopes.com info@optikamicroscopes.com OPTIKA S.R.L. Via Rigla 30, Ponteranica (BG) - ITALY Tel.: ++39 035 571392 (6 linee) Telefax: ++ 39 035 571435 MAD Iberica Aparatos Cientificos c/. Puig i Pidemunt, nº 28 1º 2ª - (Pol. Ind. Plà d en Boet) 08302 MATARO (Barcelona) España Tel: +34 937.586.245 Fax: +34 937.414.529 Alpha Optika Microscopes Hungary 2030 ÉRD, Kaktusz u. 22.- HUNGARY Tel.: (23) 520-077 Fax: (23) 374-965 OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com