1 DHEA-S EIA WELL REF KS19EW 96 Italiano p. 3 English p. 12 M146 Rev.6 05/2009

2 REAGENTI DEL KIT - KIT REAGENTS Reag, Reac Quant. MTP 1 x 96 pozz./wells Pronti per l'uso, Ready for use CAL 6 x 1 ml Liof., Lyoph. CONJ 1 x 2.7 ml Conc. DIL CONJ 2 x 12 ml Pronto per l'uso, Ready for use CTR 1 x 1 ml Liof., Lyoph. WASH 1 x 50 ml Conc. TMB 1 x 15 ml Pronto per l'uso, Ready for use SUBS 1 x 15 ml Pronto per l'uso, Ready for use STOP 1 x 14 ml Pronto per l'uso, Ready for use "Le Istruzioni per l'uso tradotte nelle altre lingue di interesse sono consultabili sul sito Internet all'indirizzo The instructions for use available in the other languages of interest can be viewed on our website Οι οδηγίες χρήσης μεταφρασμένες στις άλλες ενδιαφερόμενες γλώσσες όπως επίσης στην ηλεκτρονική διεύθυνση In den anderen Sprachen von Interesse ist die Bedienungsanleitung kann auf der Website unter der Adresse konsultiertwerden. "Le mode d emploi dans les autres langues intéressées est consultable sur le site Internet à l'adresse Las instrucciones de uso traducidas en los otros idiomas de interés se pueden consultar en nuestro sitio Internet "As instruções de uso traduzidas nos outros idiomas de interesse podem ser consultadas no nosso site Internet, ao endereço M146 Rev.6 05/2009 Pag. 2/24

3 DOSAGGIO IMMUNOENZIMATICO PER LA DETERMINAZIONE QUANTITATIVA DEL DEIDROEPIANDROSTERONE SOLFATO (DHEA-S) NEL SIERO O PLASMA UMANO. PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE Il Deidroepiandrosterone solfato (DHEA-S) è un ormone steroideo a 19 atomi di carbonio, secreto in massima parte dalla zona reticolare della corteccia surrenalica. La sua concentrazione plasmatica è estremamente elevata, ed è circa 500 volte superiore a quella del DHEA, a causa della sua più lenta clearance metabolica. Il DHEA-S circola legato all'albumina sierica, ma non alla SHBG. Le concentrazioni sieriche di DHEA-S non presentano variazioni circadiane, né fluttuazioni legate al ciclo mestruale. Il DHEA-S viene eliminato nelle urine, dove i suoi metaboliti costituiscono la quota principale dei 17-chetosteroidi. Il DHEA-S ha un'attività androgenica piuttosto debole, ma può essere metabolizzato a androstenedione e testosterone, che hanno un effetto virilizzante molto maggiore. Le concentrazioni sieriche di DHEA-S sono elevate alla nascita, e decrescono durante le prime 3 settimane di vita, fino a raggiungere i valori normali del bambino prepubere. A partire dai 6 anni circa i livelli di DHEA-S cominciano ad aumentare gradualmente, raggiungendo verso i anni i valori riscontrabili negli adulti. In caso di pubertà ritardata i livelli di DHEA-S si mantengono più bassi della norma, mentre in un quadro clinico di pubertà precoce il DHEA-S è elevato rispetto all'età ossea e in accordo con lo sviluppo pilifero del pube. Dalla pubertà fino ai anni i livelli di questo steroide si mantengono costanti; successivamente si osserva, in entrambi i sessi, una loro graduale diminuzione. Durante la gravidanza la concentrazione sierica di DHEA-S diminuisce gradatamente, raggiungendo a termine valori all'incirca dimezzati rispetto ai normali. Il dosaggio del DHEA-S è di grande utilità nell'indagare la funzionalità surrenalica in una serie di patologie endocrine. Tra di esse elenchiamo: Ipersurrenalismo: nell'irsutismo di origine surrenalica si riscontrano elevati valori di DHEA-S, e questi valori sono significativamente maggiori nelle forme di irsutismo sostenute da processi eteroplasici rispetto a quelle funzionali. Alti livelli di DHEA-S si riscontrano spesso nella sindrome da ovaio policistico. Il dosaggio del DHEA-S è inoltre consigliabile durante i test dinamici di soppressione surrenalica; a differenza del Cortisolo, che torna ai valori di presoppressione dopo circa 24 ore dalla sospensione del blocco con Desametazone, i valori del DHEA-S rimangono soppressi per giorni. Iposurrenalismo: il DHEA-S nelle forme di iposurrenalismo primario o secondario risulta al di sotto della norma. Infertilità: nella donna irsuta amenorroica la soppressione farmacologica del DHEA-S porta ad un ripristino del ciclo mestruale e della fertilità. M146 Rev.6 05/2009 Pag. 3/24

4 Sindrome virilizzante da iperplasia surrenalica congenita: in questo quadro clinico i valori di DHEA-S risultano marcatamente elevati. PRINCIPIO DEL METODO Il presente kit è basato su un metodo immunoenzimatico competitivo ed impiega quale fase solida pozzetti sensibilizzati con anticorpi anti-dhea-s specifici. Aggiungendo nei pozzetti il siero del paziente ed il coniugato (DHEA-S coniugato con perossidasi di rafano) si ha competizione tra DHEA-S sierico e coniugato per i siti leganti degli anticorpi. Al termine dell'incubazione, il materiale non legato viene rimosso mediante aspirazione e lavaggio. L'attività enzimatica rimasta fissata sulla fase solida sarà quindi inversamente proporzionale alla concentrazione di DHEA-S nei Calibratori e nei Campioni, e viene evidenziata aggiungendo ai pozzetti una soluzione di Cromogeno (tetrametilbenzidina, TMB) e un Tampone Substrato. L'intensità del colore sviluppato viene misurata mediante uno spettrofotometro a 450 e 405 nm. REAGENTI CONTENUTI NEL KIT: PREPARAZIONE E STABILITA' I reagenti sono sufficienti per 96 pozzetti. Il kit deve essere conservato a 2-8 C. La data di scadenza di ciascun reagente è indicata sulla rispettiva etichetta. Una volta aperto, il kit è stabile 2 mesi a 2-8 C. MTP Micropiastra Sensibilizzata: 1 micropiastra con 96 pozzetti separabili singolarmente, sensibilizzati con anticorpi specifici anti-dhea-s (coniglio). I pozzetti non utilizzati devono essere conservati a 2-8 C nella bustina di plastica trasparente fornita, sigillata accuratamente. CAL Calibratori: 6 flaconi contenenti DHEA-S in PBS, BSA e stabilizzanti, in forma liofila, alle seguenti concentrazioni: 0, 0.1, 0.3, 1, 3 e 10 µg/ml. Conservante: Neomicina. Ricostituire ciascun flacone con 1 ml di H 2 O distillata. Dopo ricostituzione, conservare a 2-8 C per 7-10 giorni; per periodi più lunghi congelare a -20 C. N.B.: verificare sempre l'esatta concentrazione sul foglio di C.Q. CONJ Coniugato Enzimatico (concentrato): 1 flacone (2.7 ml) di DHEA-S, coniugato con perossidasi di rafano (HRPO) in tampone TRIS con BSA e stabilizzanti. Conservante: Neomicina. Al momento dell'uso, aggiungere 1.2 ml di Coniugato al flacone del Diluente del Coniugato Enzimatico, mescolando accuratamente. Il Coniugato diluito è stabile per 8 settimane a 2-8 C. DIL CONJ Diluente del Coniugato Enzimatico: 2 flaconi (12 ml) di tampone TRIS con BSA e ANS. Pronto per l'uso. Conservante: Neomicina. M146 Rev.6 05/2009 Pag. 4/24

5 CTR Siero di Controllo: 1 flacone di DHEA-S in matrice sierica, liofilo. Conservante: Neomicina. Ricostituire con 1 ml di H 2 O distillata. Dopo ricostituzione, conservare a 2-8 C per 7-10 giorni; per periodi più lunghi congelare a -20 C. N.B.: verificare sempre l'esatta concentrazione sul foglio di C.Q. WASH Soluzione di Lavaggio (concentrata): 1 flacone (50 ml) di PBS- Tween20. Conservante: Mertiolato (<0.05%). Portare il contenuto del flacone a 500 ml con H 2 O distillata. Nel caso siano presenti cristalli insoluti, risospenderli ponendo il flacone a 37 C per qualche minuto. La soluzione diluita è stabile 1 mese a 2-8 C. TMB Cromogeno: 1 flacone (15 ml) di tetrametilbenzidina in tampone citratofosfato e DMSO. Pronto per l'uso. SUBS Tampone Substrato: 1 flacone (15 ml) di tampone citrato-fosfato e H 2 O 2. Pronto per l'uso. N.B.: Per ottenere la Soluzione Substrato, miscelare in parti uguali il Cromogeno (8) con il Tampone Substrato (9) utilizzando un flacone scuro e ben pulito; tenere la soluzione così preparata al riparo dalla luce. Dispensare la soluzione entro 1 ora dal momento della preparazione. STOP Reagente Bloccante: 1 flacone (14 ml) di H 2 SO 4 1N. Pronto per l'uso. CPA Copripiastra adesivo Bustina di plastica trasparente con minigrip MATERIALE NECESSARIO MA NON FORNITO Dosaggio Manuale Micropipette automatiche a punte intercambiabili a volume variabile. Termostato ad aria, regolabile a 37 C. Cilindro graduato. Pompa aspirante oppure apparecchiatura automatica per il lavaggio delle micropiastre. Spettrofotometro di precisione per micropiastre, con possibilità di misura in assorbanza nell'intervallo A ad una lunghezza d'onda di 450 nm e a 405 nm. Carta millimetrata. H 2 O distillata. Dosaggio Automatico Il dispositivo può essere utilizzato con strumentazione automatica di kit ELISA su micropiastra. Si garantisce l applicabilità su strumentazione RADIM e/o SEAC M146 Rev.6 05/2009 Pag. 5/24

6 Qualora si utilizzi strumentazione automatica di altri fornitori, è responsabilità dell utilizzatore assicurarsi che il kit sia stato opportunamente validato. AVVERTENZE E PRECAUZIONI Per ottenere risultati corretti e riproducibili, è necessario osservare le seguenti norme: Non mescolare i reagenti specifici (vedi 3.1) di lotti differenti. E possibile utilizzare reagenti comuni (vedi 3.2) di lotti differenti. Non usare i reagenti dopo la data di scadenza. Non esporre i reattivi e i campioni a calore intenso o a forti sorgenti di inquinamento. Usare vetreria perfettamente pulita ed esente da contaminazioni di ioni metallici o sostanze ossidanti. Usare acqua distillata o deionizzata, conservata in recipienti perfettamente puliti. Evitare accuratamente contaminazioni tra campioni; a tal fine è consigliabile usare pipette con puntali monouso per ogni campione e per ogni reattivo. Non modificare in alcun modo il Procedimento Operativo di esecuzione del test. Eventuale non rispetto di: sequenza e quantità nell aggiunta dei reattivi tempi e temperatura di incubazione può dare luogo a risultati clinici errati. Ricostituire gli eventuali reagenti liofili secondo le modalità descritte sulle etichette. Eventuale utilizzo di reattivi o volumi non idonei, può provocare l ottenimento di dati clinici non attendibili. In caso di procedura manuale è importante l utilizzo di pipette calibrate e possedere un adeguata manualità tecnica. In particolare è essenziale una buona precisione nella preparazione e dispensazione dei reattivi. E necessario un adeguato piano di manutenzione (pulizia e calibrazione) di tale strumentazione. Accertarsi che tutta la strumentazione usata (vetreria, agitatore e lavatore per micropiastre, spettrofotometro, stufa termostatata, frigoriferi usati per la conservazione dei kit e dei campioni) sia perfettamente funzionante, adeguatamente calibrata e sia soggetta ad un regolare piano di manutenzione. Un uso non accurato di ognuno di questi strumenti può produrre errori metodologici che possono condizionare la riproducibilità e l affidabilità dei risultati ottenuti. Utilizzare un adeguato metodo per la corretta identificazione dei campioni. Possibili conseguenze possono essere sia la perdita di specificità del dispositivo che risultati analitici errati. Utilizzare un adeguato metodo per la corretta identificazione dei campioni. Possibili conseguenze possono essere sia la perdita di specificità del dispositivo che risultati analitici errati. M146 Rev.6 05/2009 Pag. 6/24

7 Per evitare contaminazioni personali ed ambientali, è necessario osservare le seguenti norme di sicurezza: Utilizzare guanti monouso durante la manipolazione di materiale potenzialmente infetto e durante il dosaggio. Non pipettare i reagenti con la bocca. Non fumare, mangiare, bere o applicare cosmetici durante l'esecuzione del dosaggio. Le soluzioni di Cromogeno e Reagente Bloccante vanno manipolate con cautela. Evitare il contatto con la pelle, gli occhi e le mucose. In caso di incidente lavare abbondantemente con acqua. I materiali di origine umana utilizzati nella preparazione del presente kit sono stati saggiati per la presenza di HBsAg, anti-hiv e anti-hcv e sono risultati ripetutamente negativi. Comunque nessun test attualmente disponibile garantisce l'assenza degli agenti virali responsabili della sindrome da immunodeficienza acquisita, dell'epatite B ed epatite C. Tutti i reagenti contenenti materiale biologico e tutti i campioni di siero umano devono essere considerati potenzialmente infettivi. Evitare la produzione di schizzi e la formazione di aerosol; qualora ciò si verificasse ripulire accuratamente con ipoclorito di sodio ad una concentrazione del 3%. Il mezzo adoperato per la pulizia deve essere trattato come residuo potenzialmente infetto ed eliminato secondo le modalità opportune. Ai sensi del D.L. italiano n. 22 del , che fa riferimento alle direttive CEE (91/156/CEE, 91/689/CEE, 94/62/CEE) tutti i rifiuti provenienti da lavorazioni manuali e/o in automatico sono classificati rifiuti speciali pericolosi con codice di classificazione CER ; devono quindi essere eliminati affidandoli a ditte autorizzate al ritiro ed allo smaltimento. RACCOLTA E PREPARAZIONE DEI CAMPIONI Il dosaggio può essere effettuato su siero o plasma prelevato con EDTA. I campioni fortemente lipemici od emolizzati devono essere scartati. I campioni possono essere conservati a 2-8 C per 1-2 giorni; per periodi più lunghi conservarli a -20 C. I campioni di plasma possono presentare filamenti di fibrina che interferiscono nel dosaggio; assicurarsi pertanto che i campioni siano perfettamente limpidi prima di dosarli. Si consiglia di non congelare e scongelare ripetutamente i campioni. PROCEDIMENTO OPERATIVO* Attendere che i reagenti ed i campioni raggiungano la temperatura ambiente. Agitare i campioni per inversione prima dell'uso. M146 Rev.6 05/2009 Pag. 7/24

8 1 - Preparare i pozzetti per: Bianco, Calibratori, Siero di Controllo e Campioni. 2 - Dispensare 20 µl di ciascun Calibratore, del Siero di Controllo e dei Campioni nei rispettivi pozzetti. 3 - Dispensare 200 µl di Coniugato Enzimatico in tutti i pozzetti, eccetto quelli del Bianco. 4 - Coprire la micropiastra con il foglio adesivo ed agitare delicatamente la piastra. 5 - Incubare per 60 minuti a 37 C. 6 - Rimuovere il foglio adesivo ed aspirare accuratamente la miscela di incubazione da tutti i pozzetti. 7 - Lavare i pozzetti 4 volte con 350 µl di Soluzione di lavaggio diluita. Aspirare completamente il liquido da tutti i pozzetti. 8 - Dispensare 200 µl della soluzione Cromogeno-Substrato (vedi paragrafo reagenti), in tutti i pozzetti. 9 - Incubare per 15 minuti a 37 C al riparo dalla luce troppo intensa Dispensare 100 µl di Reattivo Bloccante in tutti i pozzetti Leggere la densità ottica delle soluzioni a 450 nm e a 405 nm in uno spettrofotometro preferibilmente bicromatico, con lunghezza d'onda di riferimento a 620 nm (azzerando lo strumento con il Bianco). La lettura può essere effettuata entro 20 minuti dal termine del dosaggio. * Qualora si utilizzasse nel procedimento operativo uno strumento automatico per micropiastre RADIM e/o SEAC, far riferimento al relativo manuale. SCHEMA DEL DOSAGGIO: vedi p. 23 CALCOLO DEI RISULTATI Nel caso si utilizzi uno strumento automatico per micropiastre RADIM e/o SEAC, la lettura spettrofotometrica è eseguita automaticamente a 3 lunghezze d'onda: 450, 405 e 620 nm, permettendo l'ampliamento del range di lettura. Al fine di ottenere una migliore sensibilità, il presente metodo utilizza una lettura spettrofotometrica a due lunghezze d'onda (450 e 405 nm). Per i campioni con concentrazione di DHEA-S compresa tra 1 e 10 µg/ml dovrà essere utilizzata la misura a 450 nm; per campioni con livelli di DHEA-S inferiori a 1 µg/ml, il calcolo dovrà essere effettuato sulle misure a 405 nm. Disegnare la curva di calibrazione su carta millimetrata, riportando sull'asse delle ascisse le dosi dei calibratori e su quello delle ordinate l'assorbanza ottenuta per ciascun calibratore. Interpolando sulla curva di calibrazione le assorbanze relative a ciascun campione si otterranno le corrispondenti concentrazioni di DHEA-S in µg/ml. M146 Rev.6 05/2009 Pag. 8/24

9 ESEMPIO DI CALCOLO I valori sotto riportati devono essere considerati unicamente un esempio e non devono essere utilizzati in luogo dei dati sperimentali. Descrizione Assorb. 450 nm DHEA-S Assorb. 405 nm DHEA-S Calibratore 0 µg/ml > Calibratore 0.1 µg/ml > Calibratore 0.3 µg/ml Calibratore 1.0 µg/ml Calibratore 3.0 µg/ml Calibratore 10.0 µg/ml Campione 1 > µg/ml Campione µg/ml VALORI NORMALI I valori riportati nella tabella seguente sono soltanto indicativi. Si raccomanda a ciascun laboratorio di stabilire i propri intervalli di riferimento. Sesso Donna Uomo Età µg/ml µg/ml Neonati Prepuberi Adulti Gravidanza > 50 anni Criteri di accettazione Prima di procedere al calcolo dei risultati, verificare che la concentrazione del siero di controllo rientri nel range di accettazione descritto nel Foglio di Controllo Qualità. CARATTERISTICHE METODOLOGICHE SPECIFICITÀ L'antisiero anti-dhea-s utilizzato ha mostrato le seguenti reazioni crociate: 100% con DHEA-S e DHEA, 19% con Androstenedione, 9% con Androsterone e inferiore allo 0.01% con Testosterone, DHT, 17-OH-Progesterone, Progesterone ed Estrone. M146 Rev.6 05/2009 Pag. 9/24

10 SENSIBILITÀ La sensibilità è stata calcolata sulla curva di calibrazione ed espressa come minima dose significativamente distinguibile dalla risposta del Calibratore Zero (valore medio - 3 D.S.). Tale dose è risultata pari a 0.08 µg/ml. PRECISIONE La precisione é stata valutata misurando la variabilità intra-saggio ed inter-saggio su 3 sieri a differenti concentrazioni di DHEA-S. Intra-saggio (Ripetibilità) Siero Media ± D.S. C.V. Replicati (µg/ml) % n. a ± b 1.39 ± c 2.61 ± Inter-saggio (Riproducibilità) Siero Media ± D.S. C.V. Dosaggi (µg/ml) % n. a 0.52 ± b 1.25 ± c 2.48 ± ACCURATEZZA L'accuratezza del metodo è stata valutata mediante il test di recupero ed il test di parallelismo: Test di Recupero Quantità scalari di DHEA-S sono state aggiunte ad un campione di siero e dosate. Aggiunto Atteso Misurato Recupero (µg/ml) (µg/ml) (µg/ml) % S S S S M146 Rev.6 05/2009 Pag. 10/24

11 Test di Parallelismo Un siero ad elevato contenuto di DHEA-S è stato dosato a varie diluizioni con il Calibratore Zero. Diluizione Atteso Misurato (µg/ml) (µg/ml) S2 indiluito : : : LIMITI DEL DOSAGGIO I risultati del dosaggio devono essere interpretati con cautela e convalidati da valutazioni cliniche ed ulteriori prove diagnostiche LEGENDA SIMBOLI: vedi p. 20 M146 Rev.6 05/2009 Pag. 11/24

12 ENZYMEIMMUNOASSAY FOR QUANTITATIVE DETERMINATION OF DEHYDROEPIANDROSTERONE-SULPHATE (DHEA-S) IN HUMAN SERUM OR PLASMA. FOR IN VITRO DIAGNOSTIC USE ONLY CLINICAL APPLICATIONS Dehydroepiandrosterone-sulphate (DHEA-S) is a steroid hormone (19 carbon atoms) secreted mainly by the zone reticularis of the adrenal cortex. Its concentration in human plasma is extremely high (about 500 times higher than DHEA) due to its slower metabolic clearance. DHEA-S circulates bound to serum albumin but not to SHBG. Serum DHEA-S lacks a circadian rhythm, nor does it exhibit fluctuations related to the menstrual cycle. It is eliminated through the urine, in which it accounts for the major fraction of 17-ketosteroids. The androgenic activity of DHEA-S is rather weak, although it can be metabolized into androstenedione and testosterone, both having a much greater virilizing effect. DHEA-S serum concentrations are high at birth, thence decreasing in the newborn during the first three weeks of life, until the normal values of pre-pubertal children are reached. Starting from about six years of age, DHEA-S levels gradually begin to rise until adult values are reached around years of age. Low serum DHEA-S levels have been found in case of delayed puberty, while the opposite has been observed in precocious puberty (DHEA-S levels higher as compared to skeletal age and based upon pubic hair growth). From puberty up to years of age DHEA-S levels remain steady, after which a progressive decrease is observed in both sexes. During pregnancy, serum DHEA-S levels follow a gradual decrease until a 50% reduction with respect to normal values is reached at pregnancy term. DHEA-S measurement is an important tool in checking adrenal function in several pathologies among which we mention: Adrenal hyperfunction: high DHEA-S levels are observed in hirsutism of adrenal origin and these levels are significantly higher in the forms of hirsutism due to heteroplasic processes as compared to functional hirsutism. DHEA-S concentrations are often high in polycystic ovary syndrome. DHEA-S measurement is also advisable during adrenal suppression tests: as opposed to Cortisol (which returns to previous levels, 24 hours after suspending dexamethasone administration), DHEA-S values remain suppressed for days. Adrenal hypofunction: DHEA-S values in primitive or secondary hypoadrenalism are below normal. Infertility: In hirsute amenorrheic women, pharmacological suppression of DHEA-S restores the menstrual cycle as well as fertility. Virilizing syndrome due to congenital adrenal hyperplasia: markedly high values are reported for such cases. M146 Rev.6 05/2009 Pag. 12/24

13 PRINCIPLE OF THE ASSAY This method is based on a competitive enzyme immunoassay (EIA), where wells coated with specific anti-dhea-s antibodies are used as solid phase. During the first incubation, the sample/calibrator DHEA-S competes with the DHEA-S conjugated to horseradish peroxidase (HRPO), for binding to the specific antibody sites on the wells. After the incubation, all unbound material is removed by aspiration and washing. The residual enzyme activity found in the wells, which is inversely proportional to the DHEA-S concentration in calibrators and samples, will be evidenced by adding a Chromogen solution (Tetramethylbenzidine, TMB) in substrate buffer to the wells. Colorimetric reading will be performed by using a spectrophotometer at 450 and 405 nm. REAGENTS PROVIDED WITH THE KIT: PREPARATION AND STABILITY The reagents are sufficient for 96 tests. Store the kit at 2-8 C. The expiry date of each reagent is shown on the vial label. Once opened the kit is stable at 2-8 C for 2 months MTP Coated Microplate: 1 microplate with 96 breakable wells, coated with anti- DHEA-S specific antibodies (rabbit). Keep unused wells at 2-8 C in the provided plastic bag and carefully sealed. CAL Calibrators: 6 vials of DHEA-S in PBS, BSA and stabilizers, lyophilized, at the following concentrations: 0, 0.1, 0.3, 1, 3 and 10 µg/ml. Preservative: Neomycin. Reconstitute each vial with 1 ml of distilled H 2 O. After reconstitution, store at 2-8 C for 7-10 days; for longer periods freeze at-20 C. NOTE: refer to the C.Q. sheet, for exact concentrations. CONJ Enzyme Conjugate (concentrated): 1 vial (2.7 ml) of DHEA-S conjugated to horseradish peroxidase (HRPO) in TRIS buffer with BSA and stabilizers. Preservative: Neomycin. Before use, add 1.2 ml of Conjugate to the Conjugate Diluent vial and mix thoroughly. Store the diluted Conjugate at 2-8 C for 8weeks. DIL CONJ Conjugate Diluent: 2 vials (12 ml) of TRIS buffer with BSA and ANS. Ready for use. Preservative: Neomycin. CTR Control Serum: 1 vial of DHEA-S in serum matrix. Lyophilized. Preservative: Neomycin. Reconstitute with 1 ml of distilled H 2 O. After reconstitution, store at 2-8 C for 7-10 days; for longer periods freeze at -20 C. NOTE: refer to the C.Q. sheet, for exact concentrations. WASH Washing Solution (concentrated): 1 vial (50 ml) of PBS-Tween 20. Preservative: Thimerosal (<0.05%). Take vial content to 500 ml with distilled H 2 O. In presence of undissolved crystals, re-suspend the solution by placing the vial at 37 C for a few minutes. Store the diluted Washing Solution at 2-8 C for 1 month. M146 Rev.6 05/2009 Pag. 13/24

14 TMB Chromogen: 1 vial (15 ml) of Tetramethylbenzidine with citrate-phosphate buffer and DMSO. Ready for use. SUBS Substrate Buffer: 1 vial (15 ml) of citrate-phosphate buffer and H 2 O 2. Ready for use. NOTE: In order to obtain the Substrate Solution, mix equal volumes of Chromogen (8) with Substrate Buffer (9) by using a dark, thoroughly clean vial. Avoid direct light exposure and use within 1hour from preparation. STOP Blocking Reagent: 1 vial (14 ml) of 1N H 2 SO 4. Ready for use. CAP Adhesive plate sealer Plastic bag with minigrip MATERIAL REQUIRED BUT NOT SUPPLIED Manual Test Adjustable, automatic micropipettes with disposable tips. Dry Heater, adjustable at 37 C. Graduated cylinder. Aspiration pump or automated well washing device. Microplate spectrophotometer capable of measuring absorbances within a A interval at 450 and 405 nm. Millimetric graph paper. Distilled H 2 O. Automatic Test This test can be used with automatic instrument for ELISA kits on microplate. We guarantee its applications on RADIM and/or SEAC automatic instruments. While using a non RADIM or SEAC automatic instrument for microplate, it is under end user responsibility, to make sure that it was appropriately tested for ELISA kits. WARNINGS AND PRECAUTIONS In order to obtain correct and reproducible results, the following rules must be observed: Do not mix specific reagents (see 3.1) from different lots. It is possible to use common reagents (see 3.2) from different lots. Do not use reagents beyond their expiry date. Do not store or leave reagents and samples at high temperatures or areas of possible contamination. Use thoroughly clean glassware, free from metal ion contamination or oxidizing substances. Use distilled or deionized water, stored in perfectly clean containers. M146 Rev.6 05/2009 Pag. 14/24

15 Carefully avoid any contamination among samples; for this purpose, disposable tips should be used for each sample and reagent. Do not modify the "Assay Procedure", in any way. Altering: volume of reagent added exact temperature and incubation times may cause incorrect clinical results. Reconstitute lyophilized reagents, if present, as described on the relative labels. Any deviation in reagent use or wrong volumes, may affect the reliability of results obtained. In case of manual procedure, it is important to use calibrated pipettes and have appropriate technical manuals. Primary importance is a good precision preparing and dispensing the reagents. Ensure that all the equipment used is in perfect working order, has been correctly calibrated and is regularly maintained. Ensure that all the equipment used (glassware, dry heater, microplate shaker, microplate washers, spectrophotometer and fridge/freezers used for reagent and sample storage) is in perfect working order, has been correctly calibrated and is regularly maintained. Any deviation from the correct use of the equipment listed can produce errors in the methodology, this may affect the reproducibility and reliability of results obtained. Utilise a suitable method for the correct identification of patient samples. Incorrect identification may cause a specificity losses of the system and wrong clinical results. In order to avoid personal and environmental contamination, the following precautions must be observed: Use disposable gloves while handling potentially infectious material and while performing the assay. Do not pipette reagents by mouth. Do not smoke, eat, drink or apply cosmetics during the assay. Chromogen and Blocking Reagent should be handled with care. Avoid contact with skin, eyes and mucous membranes. In case of accident rinse thoroughly with running water. All material of human origin used for the preparation of this kit tested negative for HBsAg, anti-hiv and anti-hcv. Since no test at present can guarantee complete absence of these viruses, all samples and reagents containing biological material used for the assay must be considered potentially infectious. Avoid splashing and aerosol formation; in such cases, carefully wash with a 3% sodium hypochlorite solution. Any such cleaning material must be treated as potentially infectious and disposed of accordingly. According to Italian decree D.L. no. 22 dated , in compliance with EEC directives (91/156/EEC, 91/689/EEC, 94/62/EEC), all waste products originating from either manual and/or automated processing are classified as hazardous special waste material (European classification code180103). As M146 Rev.6 05/2009 Pag. 15/24

16 such, they must be eliminated by delegating to special enterprises, qualified for waste collection and disposal. SPECIMEN COLLECTION AND PREPARATION The assay can be performed in serum or EDTA-collected plasma samples. Highly lipemic or hemolyzed samples must be discarded. Keep samples at 2-8 C for 1-2days; for longer periods it is advisable to freeze samples at -20 C. Plasma samples may present fibrin filaments which could interfere with the assay; make sure that samples are always perfectly clear before testing. Repeated freezing and thawing of samples should be avoided. ASSAY PROCEDURE* Allow reagents and samples to warm up at room temperature. Mix samples by inversion before use. 1 - Prepare the wells for: Blank, Calibrators, Control Serum and Samples. 2 - Pipette 20 µl of each Calibrator, Control Serum and Sample into the corresponding wells. 3 - Add 200 µl of Enzyme Conjugate into each well, except for the Blank well. 4 - Cover the microplate with the adhesive sheet and mix gently. 5 - Incubate for 60 minutes at 37 C. 6 - Remove the adhesive sheet and carefully aspirate the incubation mixture from all wells. 7 - Wash the wells 4 times with 350 µl of diluted Washing Solution. Aspirate all liquid from the wells. 8 - Pipette 200 µl of Substrate-Chromogen solution (see reagent paragraph) into all wells. 9 - Incubate for 15 minutes at 37 C, avoid direct light exposure Pipette 100 µl of Blocking Reagent into all wells Read the absorbance of the wells with a bichromatic spectrophotometer at 450 and 405 nm, with reference wavelength at 620 nm (setting the instrument at zero with the Blank well). Reading must be completed within 20 minutes from the end of the assay. * While using for the procedure a RADIM and/or SEAC automatic instrument for microplates, refer to its relative manual. ASSAY SCHEME: see p. 23 CALCULATION OF RESULTS M146 Rev.6 05/2009 Pag. 16/24

17 In order to obtain a better sensitivity, the present method employs spectrophotometric reading at two wavelengths (450 and 405 nm). For samples with DHEA-S concentrations ranging from 1 to 10 µg/ml, read at 450 nm; for samples with DHEA-S levels lower than 1 µg/ml, read at 405nm. Draw a calibration curve on millimetric graph paper, by plotting the calibrators concentrations (x-axis) against the absorbance obtained for each calibrator (yaxis). Corresponding DHEA-S concentrations in µg/ml are obtained by interpolating the absorbances of each sample on the calibration curve. EXAMPLE OF CALCULATION The values shown below must be considered as an example and must not be used in place of experimental data. Description Absorb. 450 nm DHEA-S Absorb. 405 nm DHEA-S Calibrator 0 µg/ml > Calibrator 0.1 µg/ml > Calibrator 0.3 µg/ml Calibrator 1.0 µg/ml Calibrator 3.0 µg/ml Calibrator 10.0 µg/ml Sample 1 > µg/ml Sample µg/ml NORMAL VALUES The values reported below are indicative. We suggest that each laboratory establishes its own normal range. Sex Women Men Age µg/ml µg/ml Newborn Pre-pubertal Adults Pregnancy > 50 years Validation Criteria Before proceeding to calculation of results, make sure the control serum concentration is included within the value described on the Quality Control Sheet. PERFORMANCES OF THE ASSAY M146 Rev.6 05/2009 Pag. 17/24

18 SPECIFICITY The anti-dhea-s antiserum employed has given the following cross-reactions: 100% with DHEA-S and DHEA, 19% with Androstenedione, 9% with Androsterone and less than 0.1% with Testosterone, DHT, 17- Hydroxyprogesterone, Progesterone and Estrone. SENSITIVITY The sensitivity was calculated based upon the calibration curve and expressed as the minimal dose showing a significant difference from the Zero Calibrator (mean value - 3 S.D.). This dose is 0.08 µg/ml. PRECISION Precision was evaluated upon intra- and inter-assay variability, in 3 sera at different DHEA-S concentrations. Intra-assay (Repeatability) Serum Mean ± S.D. C.V. Replicates (µg/ml) % no. a ± b 1.39 ± c 2.61 ± Inter-assay (Reproducibility) Serum Mean ± S.D. C.V. Assays (µg/ml) % no. a 0.52 ± b 1.25 ± c 2.48 ± ACCURACY Accuracy of the method has been checked by the recovery and parallelism tests: Recovery Test Known amounts of DHEA-S have been added to a serum sample and tested. Added Expected Measured Recovery (µg/ml) (µg/ml) (µg/ml) % S S S S M146 Rev.6 05/2009 Pag. 18/24

19 Parallelism Test A serum with high DHEA-S concentration was tested at different dilutions with Zero Calibrator. Dilution Expected Measured (µg/ml) (µg/ml) S2 undiluted : : : LIMITS OF THE ASSAY The results of the assay must be carefully interpreted and confirmed by clinical evaluations and further diagnostic tests. SYMBOLS LEGEND: see p. 20 M146 Rev.6 05/2009 Pag. 19/24

20 12. SIMBOLI, SYMBOLS, SYMBOLES, SÍMBOLOS, SÍMBOLOS, SYMBOLE, ΣΥΜΒΟΛΑ, SYMBOLIT, SYMBOLER EN 980 EDMA REF LOT Codice di riferimento o di ordine / Reference or order code / Référence ou numéro de commande / Referencia o número de pedido / Referência ou número da encomenda / Referenz oder Bestellnummer / κωδικός προϊόντος ή παραγγελίας / Refarans veye sipariş numarsı / Referenční nebo objednací číslo Lotto / Lot / Lot / Lote / Lote / Charge / παρτίδα / Parti / šarže Data di scadenza / Expiry date / Date d expiration / Fecha de caducidad / Data de vencimento/ Verfallsdatum / Ηµεροµηνία λήξης / Son kullanma targhi / Datum expirace IVD Per uso diagnostico in-vitro / For in-vitro diagnostic use / Pour diagnostic in-vitro / Para uso diagnóstico In-vitro / Aplicação do diagnóstico In-vitro / Für den Gebrauch in der IN-VITRO-DIAGNOSTIK / για in vitro διαγνωστική χρήση / In vitro diagnostik kullanım / Pro použití in-vitro Marcatura CE secondo le direttive IVD 98/79/CE / CE marking according to IVD guidelines 98/79/EC / Marquage CE conforme aux directives IVD 98/79/EC / Marcado CE según directiva de IVD 98/79/CE / Marcação-CE segundo a directriz-ivd 98/79/CE / CE- Markierung bei Erfüllung der IVD Richtlinie 98/79/EG / Σηµανση CE βάσει κοινοτικής οδηγίας IVD 98/79/EC / 98/79/EC IVD tüzüğüne göre CE işareti / CE označení dle IVD 98/79/EU Conservare a 2-8 C / Keep at 2-8 C / Conserver à 2-8 C / Conservar a 2-8 C / conservar a 2-8 C / Lagerung bei 2-8 C / φύλαξη στους 2-8 C / 2-8 C da saklayınız / Skladovat při 2-8 C Fabbricante / Manufacturer / Fabriquant / Produzido por / Fabricante / Produkt der / κατασκευάζεται από / Tarafından üretilmiştir / Výrobce Rischio biologico / Biohazard / Risque Biologique / Riesgo Biológico / Risco Biológico / Biogefährdung/ Bιολογικός κίνδυνος / Riziko tehlike biyolojik/ Biologicky nebezpečné M146 Rev.6 05/2009 Pag. 20/24

21 Consultare la metodica operativa / Consult instructions for use / Consulter le mode opératoire / Consultar las instrucciones de uso / Consultar as instruções de uso / Schauen Sie die Arbeitsanleitung an / συμβουλευτείτε τις οδηγίες χρήσης / Kullanımda başvurulacak bilgiler / Sledujte návod k použití 96 RDATE RCNS H 2 O Sufficiente per 96 test / Sufficient for 96 tests / Suffisant pour 96 déterminations / Suficiente para 96 determinaciones / Componentes para 96 testes / Genügend für 96 Tests / επαρκεί για 96 τεστ / 96 test için yeterli / Dostačující pro 96 testů Data di Riferimento / Reference date / Date de référence / Fecha de referencia / Data de refêrencia/ Referenzdatum / ημερομηνία βαθμονόμησης / Referans Targhi / Referenční datum Ricostituire con / Reconstitute with / Reconstituer avec / Reconstituir con / Reconstituir com / Rekonstituiren mit / ανασυστάται με / Ile karıştırma / Rekonstituovat Acqua distillata o deionizzata / Deionized or distilled water / Eau deionisée ou distillée / Agua destilada o desionizada / Água destilada ou deionizada / Deionisiertes oder Destilliertes Wasser / απιονισμένο - απεσταγμένο νερό / Deiyonize veya distile su / Deionizovaná nebo destilovaná voda M146 Rev.6 05/2009 Pag. 21/24

22 BIBLIOGRAFIA-REFERENCES 1 - Abraham GE, Manlimos FS: The role of adrenal cortex in hirsutism, The Endocrine Function of the Human Adrenal Cortex edited by VHT James, M. Serio, G. Giusti, L. Martini. New York, Academic Press, 1978, p Abraham GE, Stevenson GW, Chiamori NY: Clinical indications for serum DHEA-S measurements. Clinical Lab. Products 11: 38-42, May Abraham GE: The role of the adrenal cortex in female infertility, The Infertile Female, edited by R. Givens. Chicago, Yearbook Publishers, 1979, p Maroulis GB, Manlimos FS, Abraham GE: Comparison between urinary 17- ketosteroids and serum androgens in hirsute patients. Obstet. Gynec. 49: 454, Lobo RA, Paul WL, Goebelsmann U: Dehydroepiandrosterone sulfate as an indicator for adrenal androgen function. Obstet. Gynecol. 57: 69, Buster JE, Abraham GE: Radioimmunoassay of plasma dehydroepiandrosterone sulfate. Analyt Letters 5: 543, Abraham GE: Evaluation and treatment of the hyperandrogenized woman Endocrinology of the Ovary, edited by R Scholler. Paris, Editions SEPE, 1978 pp Chakmakjian ZH, Abraham GE: Peripheral steroid levels in a patient with virilizing adrenal adenoma. Obstet. Gynecol. 47: 544, Lobo RA, Goebelsmann U: Evidence for reduced 3-β-ol hydroxysteroid dehydrogenase activity in some hirsute women thought to have polycystic ovary syndrome. J Clin. Endocrinol. Metab. 53: 394, Abraham GE, Maroulis GB, Buster JE, Chang RJ, Marshall JR: The effect of dexamethasone on serum cortisol and androgen levels in hirsute patients. Obstet. Gynecol. 47: 395, Granoff AB, Abraham GE: Peripheral and adrenal venous levels of steroids in a patient with virilizing adrenal tumor. Obstet. Gynecol. 53: 111, Abraham GE: Androgens in women: Methodological and pathophysiological aspects, Radioimmunology 1979, edited by CA Bizollon. Elsevier/North Holland Biomedical Press, 1979, pp Abraham GE: Ovarian and adrenal contribution to peripheral steroids during the menstrual cycle in two hirsute women. Obstet. Gynec. 46: 29, Abraham GE: The application of steroid radioimmunoassay to gynecologic endocrinology, in Progress in Gynecology, Vol. VI, edited by Taymore, TH Green. New York, Grune and Stratton, 1975, pp Glass AR, Dahms WT, Abraham GE, Bray GA, Swerdloff RS: Secondary amenorrhea in obesity: Etiologic role of weight-related androgen excess. Fertil Steril 30: 243, Chang RJ, Abraham GE: Effect of dexamethasone and clomiphene citrate on peripheral steroid levels and ovarian function in a hirsute amenorrheic patient. Fertil Steril 27: 640, M146 Rev.6 05/2009 Pag. 22/24

23 SCHEMA DEL DOSAGGIO - ASSAY SCHEME Reag. Pozzetti, Wells Bianco, Blank (Bo) CAL (0-5) CTR Campioni, Samples CAL (0-5) µl CTR µl ---- Campioni, Samples µl CONJ µl 200 µl 200 µl Incubare, Incubate: 37 C 60'. Aspirare e lavare, Aspirate and wash: 4 x 350 µl. TMB - SUBS 200 µl 200 µl 200 µl 200 µl Incubare, Incubate: 37 C 15'. STOP 100 µl 100 µl 100 µl 100 µl Leggere, Read: nm. M146 Rev.6 05/2009 Pag. 23/24

24 RADIM S.p.A. - Via del Mare, Pomezia (Roma) Italia Tel.: Fax: National Order Entry: Export Department: Customer Care: info@radim.com -

20x SSC Solution. For use in in situ hybridization procedures. For Research Use Only. Not for use in diagnostic procedures.

20x SSC Solution. For use in in situ hybridization procedures. For Research Use Only. Not for use in diagnostic procedures. 20x SSC Solution WB-0003-50 14 (50 ml) For use in in situ hybridization procedures For Research Use Only. Not for use in diagnostic procedures. 1. Scope of Application This product is designed for research

Dettagli

TESTOSTERONE FREE EIA WELL Determinazione immunoenzimatica diretta del Testosterone Free nel siero o plasma.

TESTOSTERONE FREE EIA WELL Determinazione immunoenzimatica diretta del Testosterone Free nel siero o plasma. TESTOSTERONE FREE EIA WELL Determinazione immunoenzimatica diretta del Testosterone Free nel siero o plasma. REF KSO015EW 96 DESTINAZIONE D USO Metodo competitivo immunoenzimatico colorimetrico per la

Dettagli

TESTOSTERONE EIA WELL Determinazione immunoenzimatica diretta del Testosterone nel siero o plasma. REF. KSO002EW

TESTOSTERONE EIA WELL Determinazione immunoenzimatica diretta del Testosterone nel siero o plasma. REF. KSO002EW TESTOSTERONE EIA WELL Determinazione immunoenzimatica diretta del Testosterone nel siero o plasma. REF. KSO002EW 96 DESTINAZIONE D USO Metodo competitivo immunoenzimatico colorimetrico per la determinazione

Dettagli

IMMUFIT LEV1 REF KCQIMMU1

IMMUFIT LEV1 REF KCQIMMU1 IMMUFIT LEV1 REF KCQIMMU1 Per Uso Diagnostico In Vitro APPLICAZIONE D USO: Questo prodotto è inteso per l uso diagnostico in vitro come controllo di qualità dell accuratezza degli immunodosaggi sui sistemi

Dettagli

CORTISOLO EIA WELL REF KS18EW. Italiano p. 3 English p. 12. M135 Rev.6 09/2007

CORTISOLO EIA WELL REF KS18EW. Italiano p. 3 English p. 12. M135 Rev.6 09/2007 CORTISOLO EIA WELL REF KS18EW 96 Italiano p. 3 English p. 12 M135 Rev.6 09/2007 Reagenti del Kit - Kit Reagents Reag, Reac Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per l'uso, Ready for use

Dettagli

GLIADINA IgG EIA WELL REF K9GG. Italiano p. 3 English p. 12. M130 Rev.9 05/2008 Pag. 1/24

GLIADINA IgG EIA WELL REF K9GG. Italiano p. 3 English p. 12. M130 Rev.9 05/2008 Pag. 1/24 GLIADINA IgG EIA WELL REF K9GG 96 Italiano p. 3 English p. 12 M130 Rev.9 05/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. MTP WASH DIL CAL CONJ TMB STOP Quant 1 x 96 Pronti per l'uso, Ready for

Dettagli

ANTI-HBc EIA WELL REF KHB2EW REF KHB2EWB. Italiano p. 3 English p. 12. M86 Rev.07 03/2007 Pag. 1/ 24

ANTI-HBc EIA WELL REF KHB2EW REF KHB2EWB. Italiano p. 3 English p. 12. M86 Rev.07 03/2007 Pag. 1/ 24 0318 ANTI-HBc EIA WELL REF KHB2EW 96 REF KHB2EWB 192 Italiano p. 3 English p. 12 M86 Rev.07 03/2007 Pag. 1/ 24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant Stato fisico, Physical state KHB2EW KHB2EWB MTP

Dettagli

DRUGFIT LEV1 LEV2 LEV3 REF KCQDRAB1 - KCQDRAB2 - KCQDRAB3

DRUGFIT LEV1 LEV2 LEV3 REF KCQDRAB1 - KCQDRAB2 - KCQDRAB3 DRUGFIT LEV1 LEV2 LEV3 REF KCQDRAB1 - KCQDRAB2 - KCQDRAB3 Per Uso Diagnostico In Vitro APPLICAZIONE D USO: Il DRUGFIT è destinato all uso come campione di controllo per monitorare le condizioni di dosaggio

Dettagli

RUBELLA IgG AVIDITY EIA WELL REF K2RGA. 45 Determinazioni. Italiano p. 3 English p. 12. M167 Rev.10 02/2006 Pag. 1/24

RUBELLA IgG AVIDITY EIA WELL REF K2RGA. 45 Determinazioni. Italiano p. 3 English p. 12. M167 Rev.10 02/2006 Pag. 1/24 0123 RUBELLA IgG AVIDITY EIA WELL REF K2RGA 96 45 Determinazioni Italiano p. 3 English p. 12 M167 Rev.10 02/2006 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP

Dettagli

FERRITINA IEMA WELL REF. KP33IW. Italiano p. 3 English p. 12. KP33IW FERRITINA IEMA WELL M108 Rev.07 12/2004 Pag. 1/24

FERRITINA IEMA WELL REF. KP33IW. Italiano p. 3 English p. 12. KP33IW FERRITINA IEMA WELL M108 Rev.07 12/2004 Pag. 1/24 FERRITINA IEMA WELL REF. KP33IW 96 Italiano p. 3 English p. 12 M108 Rev.07 12/2004 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag, Reac Quant. Stato fisico, Physical state, MTP 96 Pronti per l'uso, Ready

Dettagli

CITOMEGALOVIRUS IgG AVIDITY

CITOMEGALOVIRUS IgG AVIDITY 0123 CITOMEGALOVIRUS IgG AVIDITY EIA WELL REF K3CGA 96 45 Determinazioni Italiano p. 3 English p. 12 M169 Rev.8 02/2006 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state

Dettagli

HERPES S.V. tipo 2 IgG

HERPES S.V. tipo 2 IgG HERPES S.V. tipo 2 IgG EIA WELL REF KH2G 96 REF KH2GB 192 Italiano p. 3 English p. 12 REAGENTI DEL KIT - KIT REAGENTS M73 Rev.8 02/2006 Pag. 1/24 Reag. Quant. Stato fisico, Physical state KH2G KH2GB MTP

Dettagli

EBV VCA IgG EIA WELL REF K10VCAG. Italiano p. 3 English p. 12

EBV VCA IgG EIA WELL REF K10VCAG. Italiano p. 3 English p. 12 EBV VCA IgG EIA WELL REF K10VCAG Italiano p. 3 English p. 12 M207 Rev. 9 06/2010 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l'uso / Ready for use CAL 1 3 3 x 1.6 ml Pronti per l'uso

Dettagli

EIA WELL REF KT1EW. Italiano p. 3 English p. 9. M124 Rev.7 06/2008

EIA WELL REF KT1EW. Italiano p. 3 English p. 9. M124 Rev.7 06/2008 T3 EIA WELL REF KT1EW 96 Italiano p. 3 English p. 9 M124 Rev.7 06/2008 REAGENTI DEL KIT - KIT REAGENTS Reag Quant, Cant MTP 1 x 96 (pozz/well) Pronti per l'uso, Ready for use CAL 6 x 1 ml Pronti per l'uso,

Dettagli

TPHA SYPHILIS TEST REF KH1. Italiano p. 3 English p. 10. M67 Rev /2007

TPHA SYPHILIS TEST REF KH1. Italiano p. 3 English p. 10. M67 Rev /2007 TPHA SYPHILIS TEST REF KH1 100 Italiano p. 3 English p. 10 M67 Rev. 04 04/2007 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state DIL 1 x 20 ml Pronto per l'uso, Ready to use NEG

Dettagli

TSH RECEPTOR 3 rd GEN

TSH RECEPTOR 3 rd GEN TSH RECEPTOR 3 rd GEN Kit Elisa di 3 a generazione per la determinazione degli autoanticorpi anti-recettore TSH REF KT27IW 96 Conservare a 2-8 C Per uso diagnostico in vitro USO Il kit TSH Receptor 3 rd

Dettagli

HELICOBACTER PYLORI IgG

HELICOBACTER PYLORI IgG HELICOBACTER PYLORI IgG EIA WELL REF K5HPG 96 Italiano p. 3 English p. 12 M114 Rev.11 04/2008 Pag. 1/ 24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant.. MTP 1 x 96 WASH DIL NEG CAL CONJ TMB STOP 1 x 50 ml

Dettagli

DAPI/DuraTect-Solution

DAPI/DuraTect-Solution DAPI/DuraTect-Solution MT-0007-0.8 20 (0.8 ml) For use in in situ hybridization procedures.... In vitro diagnostic medical device according to EU directive 98/79/EC 1. Scope of Application This product

Dettagli

VARICELLA IgG EIA WELL REF K6VG. Italiano p. 3 English p. 12. M120 Rev.8 02/2008 Pag. 1/24

VARICELLA IgG EIA WELL REF K6VG. Italiano p. 3 English p. 12. M120 Rev.8 02/2008 Pag. 1/24 VARICELLA IgG EIA WELL REF K6VG 96 Italiano p. 3 English p. 12 M120 Rev.8 02/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per l'uso Ready for

Dettagli

Cat. KHB1IWT (96 Test) Cat. KHB1IWTB (192 Test)

Cat. KHB1IWT (96 Test) Cat. KHB1IWTB (192 Test) Cat. KHB1IWT (96 Test) Cat. KHB1IWTB (192 Test) Italiano p. 3 English p. 9-1 - Reagenti del Kit - Kit Reagents Reag. Quant. Stato fisico, Physical State KHB1IWT KHB1IWTB Pozzetti, Wells 96 192 Pronti per

Dettagli

INSULINA ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del livello dell Insulina nel siero o plasma umano

INSULINA ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del livello dell Insulina nel siero o plasma umano INSULINA ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del livello dell Insulina nel siero o plasma umano REF KP10IW 96 PER USO DIAGNOSTICO IN VITRO 1.APPLICAZIONI CLINICHE L'insulina

Dettagli

Δ-4-ANDROSTENEDIONE CT

Δ-4-ANDROSTENEDIONE CT Δ-4-ANDROSTENEDIONE CT REF KS15CTN 100 ITALIANO DOSAGGIO RADIOIMMUNOLOGICO PER LA DETERMINAZIONE QUANTITATIVA DELL ANDROSTENEDIONE NEL SIERO UMANO KS15CTN - 100 Determinazioni PER USO DIAGNOSTICO IN VITRO

Dettagli

URISTIKFIT LEV1 REF KCQURST1

URISTIKFIT LEV1 REF KCQURST1 URISTIKFIT LEV1 REF KCQURST1 Per Uso Diagnostico In Vitro USO PREVISTO Il controllo URISTIKFIT è destinato all uso nel laboratorio clinico come materiale di controllo nelle procedure qualitative e semiquantitative

Dettagli

Convegno Qualità Microbiologica dei Cosmetici: Aspetti Tecnici e Normativi Milano, 15 maggio Lucia Bonadonna Istituto Superiore di Sanità

Convegno Qualità Microbiologica dei Cosmetici: Aspetti Tecnici e Normativi Milano, 15 maggio Lucia Bonadonna Istituto Superiore di Sanità Convegno Qualità Microbiologica dei Cosmetici: Aspetti Tecnici e Normativi Milano, 15 maggio 2015 Lucia Bonadonna Istituto Superiore di Sanità REGOLAMENTO (CE) n. 1223/2009 DEL PARLAMENTO EUROPEO E DEL

Dettagli

MORBILLO IgM EIA WELL REF K7MM. Italiano p. 3 English p. 12. M110 Rev.9 04/2008 Pag. 1/24

MORBILLO IgM EIA WELL REF K7MM. Italiano p. 3 English p. 12. M110 Rev.9 04/2008 Pag. 1/24 MORBILLO IgM EIA WELL REF K7MM 96 Italiano p. 3 English p. 12 M110 Rev.9 04/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per l'uso Ready for

Dettagli

Allerfood (90) Screen IgG Elisa

Allerfood (90) Screen IgG Elisa Allerfood (90) Screen IgG Elisa REF KAF90 270 3 Determinazioni Dosaggio immunoenzimatico per la determinazione semi-quantitativa degli anticorpi IgG verso 90 alimenti mediterranei nel siero umano Per uso

Dettagli

Allerfood (45) Screen IgG Elisa

Allerfood (45) Screen IgG Elisa Allerfood (45) Screen IgG Elisa REF KAF45 270 6 Determinazioni Dosaggio immunoenzimatico per la determinazione semi-quantitativa degli anticorpi IgG verso 45 alimenti nel siero umano Per uso diagnostico

Dettagli

PEPTIDE C ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del Peptide C nel siero o plasma umano

PEPTIDE C ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del Peptide C nel siero o plasma umano PEPTIDE C ELISA Dosaggio immunoenzimatico per la determinazione quantitativa del Peptide C nel siero o plasma umano REF KP12IW 96 PER USO DIAGNOSTICO IN VITRO 1.APPLICAZIONI CLINICHE C-peptide è l'abbreviazione

Dettagli

FT4 EIA WELL REF KT7EW. Italiano p. 3 English p. 14. M320 Rev.2 05/2005

FT4 EIA WELL REF KT7EW. Italiano p. 3 English p. 14. M320 Rev.2 05/2005 FT4 EIA WELL REF KT7EW 96 Italiano p. 3 English p. 14 M320 Rev.2 05/2005 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 96 Pronti per l'uso, Ready for use CAL 6 x 1 ml Liofilizzato.

Dettagli

ALLwell Ingenasa Ingezim Gluten Quick

ALLwell Ingenasa Ingezim Gluten Quick ALLwell Ingenasa Ingezim Gluten Quick ELISA kit Cat. N. LFD030-Q TEST immunoenzimatico per la rivelazione quantitativa del glutine in campioni alimentari ed ambientali Manuale d uso Leggere attentamente

Dettagli

HELICOBACTER PYLORI IgG

HELICOBACTER PYLORI IgG HELICOBACTER PYLORI IgG EIA WELL REF K5HPG 96 Italiano p. 3 English p. 12 M114 Rev.10 10/2006 Pag. 1/ 24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant.. Stato fisico, Physical state MTP 96 Pronti per l'uso,

Dettagli

TEICOPLANINA QMS Saggio immunologico

TEICOPLANINA QMS Saggio immunologico 0155941-0 Gen., 2011 TEICOPLANINA QMS Saggio immunologico Prima dell'uso leggere attentamente il foglietto illustrativo del presente sistema quantitativo a microsfere (Quantitative Microsphere System -

Dettagli

PROGESTERONE ELISA Determinazione immunoenzimatica diretta del Progesterone nel siero o plasma umano

PROGESTERONE ELISA Determinazione immunoenzimatica diretta del Progesterone nel siero o plasma umano PROGESTERONE ELISA Determinazione immunoenzimatica diretta del Progesterone nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 tests REF IE164 DESTINAZIONE D USO Metodo competitivo immunoenzimatico

Dettagli

INGEZIM Gluten Quanti Test Guida all utilizzo

INGEZIM Gluten Quanti Test Guida all utilizzo INGEZIM Gluten Quanti Test Guida all utilizzo 1 - INTRODUZIONE Il kit è basato su un saggio immunoenzimatico ELISA di tipo sandwich come dettato dal Codex Alimentarius. Ogni pozzetto è rivestito sul fondo

Dettagli

Anti TRANSGLUTAMINASI IgG

Anti TRANSGLUTAMINASI IgG Anti TRANSGLUTAMINASI IgG EIA WELL R REF K10TG 96 Italiano p. 3 English p. 12 M412 Rev.1 04/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per

Dettagli

PREALBUMINA (Ref. NPP19L)

PREALBUMINA (Ref. NPP19L) PREALBUMINA (Ref. NPP19L) REAGENTE PER LA DETERMINAZIONE QUANTITATIVA DELLA PREALBUMINA UMANA NEL SIERO CON METODO NEFELOMETRICO PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE La Prealbumina è una

Dettagli

FT4 EIA WELL REF KT7EW REAGENTI DEL KIT - KIT REAGENTS. Italiano p. 3 English p. 12. M320 Rev.4 01/ Pag. 1/24

FT4 EIA WELL REF KT7EW REAGENTI DEL KIT - KIT REAGENTS. Italiano p. 3 English p. 12. M320 Rev.4 01/ Pag. 1/24 FT4 EIA WELL REF KT7EW 96 Italiano p. 3 English p. 12 REAGENTI DEL KIT - KIT REAGENTS M320 Rev.4 01/2009 - Pag. 1/24 Reag. Quant. MTP 1 x 96 CAL CONJ CTR WASH TMB SUBS STOP 6 x 1 ml 2 x 12 ml 2 x 1 ml

Dettagli

19-20 Novembre 2014, Pisa Scuola Medica della Facoltà di Medicina. Co.Me.Lab 2014

19-20 Novembre 2014, Pisa Scuola Medica della Facoltà di Medicina. Co.Me.Lab 2014 19-20 Novembre 2014, Pisa Scuola Medica della Facoltà di Medicina Co.Me.Lab 2014 Aldo Clerico Scuola Superiore Sant Anna Fondazione Regione Toscana G. Monasterio clerico@ftgm.it INTRODUZIONE Il BNP è un

Dettagli

TEICOPLANINA QMS Saggio immunologico

TEICOPLANINA QMS Saggio immunologico 0155948-0 Gen. 2011 TEICOPLANINA QMS Saggio immunologico Prima dell'uso leggere attentamente il foglietto illustrativo del presente sistema quantitativo a microsfere (Quantitative Microsphere System -

Dettagli

PSA FREE EIA REF KMT11IW 96. Italiano p. 3 English p. 17. M342 Rev /2008

PSA FREE EIA REF KMT11IW 96. Italiano p. 3 English p. 17. M342 Rev /2008 Z 0123 PSA FREE EIA REF KMT11IW 96 Italiano p. 3 English p. 17 M342 Rev. 04 09/2008 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 12 x 8 Pronti per l'uso, Ready for use WASH 1 x 50 ml Conc. CAL 6 x

Dettagli

EBV EA IgG EIA WELL REF K10EAG. Italiano p. 3 English p. 12

EBV EA IgG EIA WELL REF K10EAG. Italiano p. 3 English p. 12 EBV EA IgG EIA WELL REF K10EAG Italiano p. 3 English p. 12 M205 - Rev.10 06/2010 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l'uso, Ready for use CONJ 1 x 15 ml Pronto per l'uso,

Dettagli

Anti TRANSGLUTAMINASI IgA EIA WELL REF K10TA. Italiano p. 3 English p. 12. M290 Rev.3 04/2008 Pag. 1/24

Anti TRANSGLUTAMINASI IgA EIA WELL REF K10TA. Italiano p. 3 English p. 12. M290 Rev.3 04/2008 Pag. 1/24 Anti TRANSGLUTAMINASI IgA EIA WELL REF K10TA 96 Italiano p. 3 English p. 12 M290 Rev.3 04/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per

Dettagli

CORTISOL ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano

CORTISOL ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano CORTISOL ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 test REF E-70 DESTINAZIONE D USO Metodo competitivo immunoenzimatico

Dettagli

TRANSFERRINA (Ref. NPP6)

TRANSFERRINA (Ref. NPP6) TRANSFERRINA (Ref. NPP6) REAGENTE PER LA DETERMINAZIONE QUANTITATIVA DELLA TRANSFERRINA UMANA NEL SIERO E NELLE URINE CON METODO NEFELOMETRICO PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE La Transferrina

Dettagli

Tg-S IRMA CT REF KT4CTR. Italiano p. 3 English p. 11. M347 Rev.0 06/2004

Tg-S IRMA CT REF KT4CTR. Italiano p. 3 English p. 11. M347 Rev.0 06/2004 Tg-S IRMA CT REF KT4CTR 100 Italiano p. 3 English p. 11 M347 Rev.0 06/2004 Reagenti del Kit - Kit Reagents Reag, Reac Quant. Stato fisico, Physical state. CT 100 Pronte per l'uso, Ready for use CAL 0 1

Dettagli

β 2 - MICROGLOBULINA (Ref. NPP18N)

β 2 - MICROGLOBULINA (Ref. NPP18N) β 2 - MICROGLOBULINA (Ref. NPP18N) REAGENTI PER LA DETERMINAZIONE QUANTITATIVA DELLA β 2 -MICROGLOBULINA NEL SIERO E NELLE URINE CON METODO NEFELOMETRICO PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE

Dettagli

TPOAb IEMA WELL REF KT21IW. Italiano p. 3 English p. 12. M325 Rev.2 09/2007

TPOAb IEMA WELL REF KT21IW. Italiano p. 3 English p. 12. M325 Rev.2 09/2007 TPOAb IEMA WELL REF KT21IW 96 Italiano p. 3 English p. 12 M325 Rev.2 09/2007 Reagenti del Kit - Kit Reagents Materiale Fornito Materials Supplied Quantità Package size Formulazione Formulation Stato fisico

Dettagli

ScanGel ScanSol ml ml

ScanGel ScanSol ml ml ScanGel ScanSol 86448 100 ml 86449 500 ml MEZZO DI SOSPENSIONE DEI GLOBULI ROSSI IVD Tutti i prodotti fabbricati e commercializzati dalla società Bio-Rad sono sottoposti a un sistema di assicurazione qualità

Dettagli

FERRITINA (Ref. NPP38N)

FERRITINA (Ref. NPP38N) FERRITINA (Ref. NPP38N) REAGENTI PER LA DETERMINAZIONE QUANTITATIVA DELLA FERRITINA NEL SIERO UMANO CON METODO NEFELOMETRICO PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE La molecola della Ferritina

Dettagli

TETANUS TOXIN IgG 5S E.W.

TETANUS TOXIN IgG 5S E.W. TETANUS TOXIN IgG 5S E.W. REF K12TEG5S 96 Italiano p. 3 English p.13 M470 Rev. 1 02/2008 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l'uso, Ready for use DIL 1 x 105 ml Pronto per

Dettagli

ANTITROMBINA III (Ref. NPP22L)

ANTITROMBINA III (Ref. NPP22L) ANTITROMBINA III (Ref. NPP22L) REAGENTI PER LA DETERMINAZIONE QUANTITATIVA DELL ANTITROMBINA III NEL PLASMA UMANO CON METODO NEFELOMETRICO PER USO DIAGNOSTICO IN VITRO APPLICAZIONI CLINICHE L Antitrombina

Dettagli

CHLAMYDIA PNEUMONIAE IgG E.W.

CHLAMYDIA PNEUMONIAE IgG E.W. 0123 CHLAMYDIA PNEUMONIAE IgG E.W. REF K14CLG 96 Italiano p. 3 English p.12 M394 Rev.2 02/2008 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l'uso, Ready for use DIL 1 x 105 ml Pronto

Dettagli

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT) M/S RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 25/2014 in accordo con la norma UNI EN 14688 on lavabi BUTTERFLY TECHNOLOGIAL LABORATORY TEST REPORT N 25/2014 in compliance with the norm UNI EN 14688

Dettagli

FREE TESTOSTERONE. per analisi di routine Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano

FREE TESTOSTERONE. per analisi di routine Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano EE TTOSTERONE DCM015-12 Ed. 01/2012 per analisi di routine Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 test REF DKO015

Dettagli

ADENOVIRUS IgM E.W. REF K11ADM. Italiano p. 3 English p.12. M388 Rev. 1 02/2008

ADENOVIRUS IgM E.W. REF K11ADM. Italiano p. 3 English p.12. M388 Rev. 1 02/2008 ADENOVIRUS IgM E.W. REF K11ADM 96 Italiano p. 3 English p.12 M388 Rev. 1 02/2008 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l'uso, Ready for use DIL 1 x 105 ml Pronto per l'uso,

Dettagli

LA SACRA BIBBIA: OSSIA L'ANTICO E IL NUOVO TESTAMENTO VERSIONE RIVEDUTA BY GIOVANNI LUZZI

LA SACRA BIBBIA: OSSIA L'ANTICO E IL NUOVO TESTAMENTO VERSIONE RIVEDUTA BY GIOVANNI LUZZI Read Online and Download Ebook LA SACRA BIBBIA: OSSIA L'ANTICO E IL NUOVO TESTAMENTO VERSIONE RIVEDUTA BY GIOVANNI LUZZI DOWNLOAD EBOOK : LA SACRA BIBBIA: OSSIA L'ANTICO E IL NUOVO Click link bellow and

Dettagli

APPLICAZIONE QMS EVEROLIMUS Beckman Coulter AU680 /AU5800

APPLICAZIONE QMS EVEROLIMUS Beckman Coulter AU680 /AU5800 APPLICAZIONE QMS EVEROLIMUS Beckman Coulter AU680 /AU5800 Reagente Beckman Coulter REF A53729 (USA) Il dosaggio QMS per l'everolimus è concepito per la determinazione quantitativa di everolimus nel sangue

Dettagli

RSV IgG E.W. REF K13RSG. Italiano p. 3 English p. 12. M391 - Rev.1 02/2008

RSV IgG E.W. REF K13RSG. Italiano p. 3 English p. 12. M391 - Rev.1 02/2008 RSV IgG E.W. REF K13RSG 96 Italiano p. 3 English p. 12 M391 - Rev.1 02/2008 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. MTP 1 x 96 Pronti per l uso, Ready for use DIL 1 x 105 ml Pronto per l uso, Ready

Dettagli

PINO SOVRANO MRK

PINO SOVRANO MRK MRK 010-0724 PINO SOVRANO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante speciali

Dettagli

Platelia Measles IgG. 1 piastra /12

Platelia Measles IgG. 1 piastra /12 Platelia Measles IgG 1 piastra - 48 72686 METODO IMMUNOENZIMATICO PER LA DETERMINAZIONE QUALITATIVA DEGLI ANTICORPI IgG ANTI VIRUS DEL MORBILLO NEL SIERO UMANO 2014/12 SOMMARIO 1. UTILIZZAZIONE 2. INTRODUZIONE

Dettagli

TETA-TEST REF TE20 20

TETA-TEST REF TE20 20 TETA-TEST REF TE20 20 M287 Rev. 06 03/2006 TETA-TEST DOSAGGIO IMMUNOCROMATOGRAFICO PER LA DETERMINAZIONE VISIVA DEGLI ANTICORPI ANTI TOSSINA TETANICA IN SIERO, PLASMA O SANGUE INTERO, QUALE AUSILIO PER

Dettagli

HBsAg IRMA CT. Cat. KHB1CT 100 Test. Italiano p. 3 English p. 9

HBsAg IRMA CT. Cat. KHB1CT 100 Test. Italiano p. 3 English p. 9 HBsAg IRMA CT Cat. KHB1CT 100 Test Italiano p. 3 English p. 9 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state Provette, Tubes 100 Pronte per l'uso, Ready for use Trac. 1 x 20

Dettagli

IMMUNODOSAGGI o DOSAGGI IMMUNOLOGICI

IMMUNODOSAGGI o DOSAGGI IMMUNOLOGICI IMMUNODOSAGGI o DOSAGGI IMMUNOLOGICI IMMUNODOSAGGI o DOSAGGI IMMUNOLOGICI Preferiti ad immunodiffusione/immunoelettroforesi quando si debba effettuare uno studio quantitativo. Ampliamente utilizzati in

Dettagli

AGED WOOD MRK

AGED WOOD MRK MRK 010-0717 AGED WOOD TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante speciali

Dettagli

MIRROR FOR OUTDOOR MRK

MIRROR FOR OUTDOOR MRK MRK 010-0685 MIRROR FOR OUTDOOR ESPOSIZIONE NATURALE IN FLORIDA: Esposizione naturale Le esposizioni naturali vengono condotte in Florida presso il sito espositivo della Atlas Weathering Service; il sud

Dettagli

MORBILLO IgG EIA WELL REF K7MG. Italiano p. 3 English p. 12. M129 Rev.8 04/2008 Pag. 1/24

MORBILLO IgG EIA WELL REF K7MG. Italiano p. 3 English p. 12. M129 Rev.8 04/2008 Pag. 1/24 MORBILLO IgG EIA WELL REF K7MG 96 Italiano p. 3 English p. 12 M129 Rev.8 04/2008 Pag. 1/24 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. Stato fisico, Physical state MTP 1 x 96 Pronti per l'uso Ready for

Dettagli

SEMPLICE LED. // Schemi cablaggio // Wiring diagrams. // Istruzioni per il montaggio // Assembly instructions

SEMPLICE LED. // Schemi cablaggio // Wiring diagrams. // Istruzioni per il montaggio // Assembly instructions // Schemi cablaggio // Wiring diagrams SEMPICE ED // Istruzioni per il montaggio // Assembly instructions // Avvertenze. a sicurezza dell apparecchio è garantita solamente con l uso appropriato delle presenti

Dettagli

Spett.le M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT)

Spett.le M/S CERAMICA SCARABEO Località Pian del Trullo Fabrica di Roma (VT) Spett.le M/S RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 52a/08 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 52a/08 In compliance with the norm UNI EN 14688 RICHIESTO

Dettagli

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY M/S 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 48/2012 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 48/2012 In compliance

Dettagli

OLIVO e LEGNI GRIGI per ESTERNO MRK

OLIVO e LEGNI GRIGI per ESTERNO MRK MRK-010-0565 OLIVO e LEGNI GRIGI per ESTERNO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco

Dettagli

BEIA Helicobacter pylori IgA 20996

BEIA Helicobacter pylori IgA 20996 BEIA Helicobacter pylori IgA 20996. Edizione 20/04/2013 Solo per uso professionale TECHNOGENETICS SRL N 00539 Pag. 1-24 BEIA Helicobacter pylori IgA Ed. 20/04/2013 INTRODUZIONE Il kit BEIA Helicobacter

Dettagli

CORTISOLO ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano

CORTISOLO ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano CORTISOLO ELISA Determinazione immunoenzimatica diretta del Cortisolo nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 test REF E-70 DESTINAZIONE D USO Metodo competitivo immunoenzimatico

Dettagli

17OH PROGESTERONE ELISA Determinazione immunoenzimatica diretta del 17OH Progesterone nel siero o plasma umano.

17OH PROGESTERONE ELISA Determinazione immunoenzimatica diretta del 17OH Progesterone nel siero o plasma umano. 17OH PROGTERONE ELISA Determinazione immunoenzimatica diretta del 17OH Progesterone nel siero o plasma umano. IVD LOT See external label Σ = 96 tests REF E-46 DTINAZIONE D USO Metodo competitivo immunoenzimatico

Dettagli

LEVETIRACETAM PLASMATICO in UV - FAST Codice Z84010

LEVETIRACETAM PLASMATICO in UV - FAST Codice Z84010 LEVETIRACETAM PLASMATICO in UV - FAST Codice Z84010 INTRODUZIONE Il trattamento del paziente epilettico richiede il contributo multidisciplinare di competenze mediche, farmacologiche, psicologiche e sociali.

Dettagli

ERGO ERGO. Istruzioni per il cablaggio Wiring instructions. // Istruzioni per il montaggio // Assembly instructions

ERGO ERGO. Istruzioni per il cablaggio Wiring instructions. // Istruzioni per il montaggio // Assembly instructions ERGO Istruzioni per il cablaggio Wiring instructions 64W ON/OFF MARRONE / BROWN - Linea / line GIALLO-VERDE / YELLOW-GREEN - Terra / Earth ERGO 65 BLU / BLUE - Neutro / Neutral // Istruzioni per il montaggio

Dettagli

ALLwell Elution Technologies Bovine Casein Protein

ALLwell Elution Technologies Bovine Casein Protein ALLwell Elution Technologies Bovine Casein Protein Elisa kit Cat. N. ETE-75CAS Kit per la rilevazione della caseina bovina in campioni alimentari Manuale d uso Leggere attentamente il manuale prima di

Dettagli

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY

M/S AMARU' GIOVANNI VIA S. ERASMO snc VASCHE DI CASTEL S. ANGELO (RI) ITALY M/S 02010 VASCHE DI CASTEL S. ANGELO (RI) ITALY RAPPORTO DI PROVA del LABORATORIO TECNOLOGICO N 47b/2012 in accordo con la norma UNI EN 14688 TECHNOLOGIAL LABORATORY TEST REPORT N 47b/2012 In compliance

Dettagli

Smoke machine 400W PLFD400EL

Smoke machine 400W PLFD400EL Smoke machine 400W PLFD400EL MANUALE UTENTE USER MANUAL 1 Rev. 01-06/13 Nel caso in cui si noti una scarsa uscita di fumo, o la pompa sia particolarmente rumorosa, o non venga vaporizzato il fumo, scollegare

Dettagli

DHEA-S ELISA Determinazione immunoenzimatica diretta del Deidroepiandrosterone solfato (DHEA-S) nel siero o plasma umano

DHEA-S ELISA Determinazione immunoenzimatica diretta del Deidroepiandrosterone solfato (DHEA-S) nel siero o plasma umano DHEA-S ELISA Determinazione immunoenzimatica diretta del Deidroepiandrosterone solfato (DHEA-S) nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 tests REF E-47 STINAZIONE D USO Metodo competitivo

Dettagli

FT3 EIA WELL Determinazione immunoenzimatica diretta dell FT3 nel siero o plasma

FT3 EIA WELL Determinazione immunoenzimatica diretta dell FT3 nel siero o plasma FT3 EIA WELL Determinazione immunoenzimatica diretta dell FT3 nel siero o plasma REF KTO037EW 96 DESTINAZIONE D USO Metodo competitivo immunoenzimatico colorimetrico per la determinazione quantitativa

Dettagli

IRMAZENco TM Ab. ZenTech s.a. Liège Science Park Avenue du Pré-Aily 10, 4031 ANGLEUR, Belgium Tel. : + 32-(0) Fax : + 32-(0)

IRMAZENco TM Ab. ZenTech s.a. Liège Science Park Avenue du Pré-Aily 10, 4031 ANGLEUR, Belgium Tel. : + 32-(0) Fax : + 32-(0) IRMAZENco TM Ab ENGLISH GB ITALIANO I ZenTech s.a. Liège Science Park Avenue du Pré-Aily 10, 4031 ANGLEUR, Belgium Tel. : + 32-(0)4-361.42.32 Fax : + 32-(0)4-367.00.63 info@zentech.be www.zentech.be ISO15223

Dettagli

BAMBOO e ZEBRANO per ESTERNO MRK

BAMBOO e ZEBRANO per ESTERNO MRK MRK-010-0564 BAMBOO e ZEBRANO per ESTERNO TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco

Dettagli

FREE TESTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano

FREE TESTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano EE TTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone Libero nel siero o plasma umano IVD LOT Vedere etichetta esterna Σ = 96 test REF E-96 DTINAZIONE D USO Metodo competitivo immunoenzimatico

Dettagli

Epstein Barr Virus VCA IgG

Epstein Barr Virus VCA IgG DCM002i-0 Ed. 08/2012 Epstein Barr Virus VCA IgG per analisi di routine Dosaggio immunoenzimatico per la determinazione qualitativa e semiquantitativa di anticorpi umani di classe IgG contro l Epstein

Dettagli

bioelisa VEDI CAMBI RISALTATI

bioelisa VEDI CAMBI RISALTATI VEDI CAMBI RISALTATI bioelisa RUBELLA IgM (Immunocapture) 3000-1231 96 tests Test ELISA per la determinazione degli anticorpi IgM anti-rosolia nel siero o nel plasma umano. Sommario La rosolia, o morbillo

Dettagli

PLATELIA ASPERGILLUS IgG Negative and Positive Controls

PLATELIA ASPERGILLUS IgG Negative and Positive Controls PLATELIA ASPERGILLUS IgG Negative and Positive Controls 48 62786 Sieri Umani per il Controllo di Qualità 881090-2012/06 sommario 1. USO PREVISTO...27 2. INDICAZIONI PER L USO...27 3. REAGENTI...27 4. AVVERTENZE

Dettagli

APPLICAZIONE QMS TACROLIMUS Beckman Coulter AU480 /AU680 /AU5800

APPLICAZIONE QMS TACROLIMUS Beckman Coulter AU480 /AU680 /AU5800 APPLICAZIONE QMS TACROLIMUS Beckman Coulter AU480 /AU680 /AU5800 Reagente Beckman Coulter REF A53727 L'immunodosaggio QMS per il tacrolimus è concepito per la determinazione quantitativa di tacrolimus

Dettagli

Determinazione immunoenzimatica quantitativa del diidrotestosterone (DHT) nel siero umano

Determinazione immunoenzimatica quantitativa del diidrotestosterone (DHT) nel siero umano Determinazione immunoenzimatica quantitativa del diidrotestosterone (DHT) nel siero umano Ref. E4 USO DEL KIT Per la determinazione quantitativa diretta del DHT nel siero umano con metodo immunoenzimatico.

Dettagli

PROGESTERONE RIA CT REF KS26CTN. Italiano p. 3 English p. 12. M472 Rev. 0 09/2007

PROGESTERONE RIA CT REF KS26CTN. Italiano p. 3 English p. 12. M472 Rev. 0 09/2007 PROGESTERONE RIA CT REF KS26CTN 96 Italiano p. 3 English p. 12 M472 Rev. 0 09/2007 REAGENTI DEL KIT - KIT REAGENTS Reag. Quant. CT 2 x 48 Pronti per l'uso, Ready for use CAL 0 CAL 1-6 1 x 1 ml 6 x 0.5

Dettagli

INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI

INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI INFORMAZIONE AGLI UTENTI DI APPARECCHIATURE DOMESTICHE O PROFESSIONALI Ai sensi dell art. 13 del Decreto Legislativo 25 luglio 2005, n. 151 "Attuazione delle Direttive 2002/95/CE, 2002/96/CE e 2003/108/CE,

Dettagli

ACIDO IPPURICO e ACIDI o-m-p-metilippurici URINARI in UV Codice Z06010

ACIDO IPPURICO e ACIDI o-m-p-metilippurici URINARI in UV Codice Z06010 ACIDO IPPURICO e ACIDI o-m-p-metilippurici URINARI in UV Codice Z06010 BIOCHIMICA La determinazione dell Acido Ippurico urinario viene impiegata per il monitoraggio biologico dei soggetti esposti a Toluene.

Dettagli

RAPPORTO DI PROVA TEST REPORT

RAPPORTO DI PROVA TEST REPORT RAPPORTO DI PROVA TEST REPORT Titolo (Title): VIBRATION TEST ON FRIGOBOX T0056 Richiedente (Customer): Ente/Società (Dept./Firm): Sig. (Mr.): Indirizzo (Address): EUROENGEL S.R.L. C. SCAMARDELLA Via Ferrini,

Dettagli

TESTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone totale nel siero o plasma umano.

TESTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone totale nel siero o plasma umano. TTOSTERONE ELISA Determinazione immunoenzimatica diretta del Testosterone totale nel siero o plasma umano. IVD LOT DTINAZIONE D USO Metodo competitivo immunoenzimatico colorimetrico per la determinazione

Dettagli

EXTRA-GENE I Kit per l estrazione del DNA genomico 50 Estrazioni

EXTRA-GENE I Kit per l estrazione del DNA genomico 50 Estrazioni IT Istruzioni d uso EXTRA-GENE I Kit per l estrazione del DNA genomico 50 Estrazioni REF 7059 1. Descrizione del prodotto EXTRA-GENE è un kit per l estrazione veloce del DNA genomico senza l utilizzo di

Dettagli

Analisi Immunoenzimatiche

Analisi Immunoenzimatiche Analisi Immunoenzimatiche Mara Stefanelli INAIL Dipartimento Innovazioni Tecnologiche e Sicurezza degli Impianti, Prodotti e Insediamenti antropici Istituto Superiore di Sanità Dipartimento Ambiente e

Dettagli

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5

RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5 RAPPORTO DI CLASSIFICAZIONE CLASSIFICATION REPORT 0412\DC\REA\12_5 Rapporto di classificazione di reazione al fuoco del prodotto : Reaction to fire classification report of product BETON COLOR Descrizione

Dettagli

APOLIPOPROTEINE A-I (Ref. NPP13), B (Ref. NPP14)

APOLIPOPROTEINE A-I (Ref. NPP13), B (Ref. NPP14) APOLIPOPROTEINE A-I (Ref. NPP13), B (Ref. NPP14) REAGENTI PER LA DETERMINAZIONE QUANTITATIVA DELLE APOLIPOPROTEINE A-I (Apo A-I) E B (Apo B) NEL SIERO UMANO CON METODO NEFELOMETRICO PER USO DIAGNOSTICO

Dettagli

15 Anti-D policlonale / incompleto

15 Anti-D policlonale / incompleto Scheda Tecnica 0123 Technical File No.: Prodotto: 15 Anti-D policlonale / incompleto Categoria di prodotto secondo la classificazione CE: Allegato II Lista A Struttura della scheda tecnica Descrizione

Dettagli